hpc’s most intelligent storage solution193.62.125.70/ciuk2017/cray.pdf · 2018. 2. 6. · 11 mira...

29
1 HPC’s most Intelligent Storage Solution

Upload: others

Post on 01-Oct-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: HPC’s most Intelligent Storage Solution193.62.125.70/CIUK2017/Cray.pdf · 2018. 2. 6. · 11 Mira BlueGene/Q, Power BQC 16C 1.60GHz, Custom GPFS 28.8 240 12 Stampede2 Dell PowerEdge

1

HPC’s most Intelligent Storage Solution

Page 2: HPC’s most Intelligent Storage Solution193.62.125.70/CIUK2017/Cray.pdf · 2018. 2. 6. · 11 Mira BlueGene/Q, Power BQC 16C 1.60GHz, Custom GPFS 28.8 240 12 Stampede2 Dell PowerEdge

2

What is ClusterStor…

Integrated SoftwareComplete Solution

Modular Building BlocksPerformance + Capacity

Integrated Storage Servers and

Storage Capacity featuring NXD

Flash I/O Accelerator &

De-Clustered RAID

Engineered HPC Storage SystemComplete Solution

High density 12G disk enclosures

Integrated HA Object Storage Servers

Dedicated Lustre software development,

integration, test & support team

CLI, GUI and API Integration Administration

Manufacturing integration & test validation

Maximum performance from each disk drives

Makes Lustre easier to manage at scale

Support and Professional services

Copyright Cray, Inc. 2017

Page 3: HPC’s most Intelligent Storage Solution193.62.125.70/CIUK2017/Cray.pdf · 2018. 2. 6. · 11 Mira BlueGene/Q, Power BQC 16C 1.60GHz, Custom GPFS 28.8 240 12 Stampede2 Dell PowerEdge

3

ClusterStor High-End Storage Leadership (8 of Top 20)Rank Name Computer File system Size (PB) Perf (GB/s)

1Sunway

TaihuLight

Sunway MPP, Sunway

260C 1.45GHz, Sunway

Sunway GFS

(Lustre)20 ~100

2 Tianhe-2TH-IVB-FEP Cluster,

Xeon E5-2692 2.2GHz,

TH Express-2, Xeon Phi

Lustre /

H2FS12.4 750

3Piz Daint

CSCS

Cray XC30, Xeon E5-

2670 8C 2.600GHz, Aries

interconnect , NVIDIA

K20x

Lustre 6 138

4 GyoukouJapan Agency for Marine-Earth Science and Tech.

5Titan

ORNL

Cray XK7 , Opteron 6274

16C 2.2GHz, Cray

Gemini, NVIDIA K20xLustre 32 700

6Sequoia

LLNL

BlueGene/Q, Power BQC

16C 1.60 GHz, Custom

InterconnectLustre 55 850

7Trinity

LANL

Cray XC40, Xeon E5-

2698v3 16C 2.3GHz,

Aries interconnect Lustre 78* 1,700

8Cori

NERSC

Cray XC40, Intel Xeon Phi

7250 68C 1.4GHz, Aries

interconnect

Lustre 30* 1000

9Oakforest-

PACS

PRIMERGY CX1640 M1,

Intel Xeon Phi 7250 68C

1.4GHz, Intel Omni-Path

Lustre 26 400

10 K computerFujitsu, SPARC64 VIIIfx

2.0GHz, , Tofu interctLustre 40 965

Nov2017 list

Rank Name Computer File system Size (PB) Perf (GB/s)

11 MiraBlueGene/Q, Power BQC

16C 1.60GHz, CustomGPFS 28.8 240

12 Stampede2 Dell PowerEdge C6320P Lustre 21* >300

13 TSUBAME3.0

SGI ICE XA, IP139-SXM2, Xeon E5-2680v4 14C 2.4GHz, Intel Omni-Path, NVIDIA Tesla P100 SXM2

14 MarconiCINECA Cluster, Intel

Xeon Phi 7250 68C

1.4GHz, Intel Omni-Path

GPFS 17 10

15 MetOfficeCray XC40, Xeon E5-

2695v4 18C 2.1GHz, AriesLustre 26* 1,000

16Mare

NostrumLenovo SD530, Xeon

Platinum 8160GPFS 14 ~ 100

17Pleiades

NASA

SGI ICE X, Intel Xeon

Infiniband FDRLustre 29 ??

18 ThetaCray XC40, Intel Xeon Phi

7230 64C 1.3GHz, Aries

interconnect

Lustre 10,1 224

19Hazel Hen

HLRS

Cray XC40, Xeon E5-

2680v3 12C 2.5GHz, AriesLustre 11 350

20Shaheen II

KAUST

Cray XC40, Xeon E5-

2698v3 16C 2.3GHz, Aries Lustre 18 >500

* usable capacity

Copyright Cray, Inc. 2017

Page 4: HPC’s most Intelligent Storage Solution193.62.125.70/CIUK2017/Cray.pdf · 2018. 2. 6. · 11 Mira BlueGene/Q, Power BQC 16C 1.60GHz, Custom GPFS 28.8 240 12 Stampede2 Dell PowerEdge

4

HPC Users who already have switched to

Page 5: HPC’s most Intelligent Storage Solution193.62.125.70/CIUK2017/Cray.pdf · 2018. 2. 6. · 11 Mira BlueGene/Q, Power BQC 16C 1.60GHz, Custom GPFS 28.8 240 12 Stampede2 Dell PowerEdge

5

ClusterStor News…

• Cray and Seagate form Strategic Partnership

• ClusterStor HPC storage product line moved to Cray

• Transaction closed on Monday, September 25th

• Sell, support, and enhance the ClusterStor product line

• Collaborate with Seagate to integrate future Seagate technologies

• Manufacturing moving to Cray’s facility in Chippewa Falls, WI

• Approximately 130 Seagate employees and contractors join Cray

• Mostly in R&D, Service and Support, and Reseller channel support

• Provides a commercial, fully supported, and up to date Lustre build

• Provides a well established solution proven at all scales

• Ensures continuity of support for ClusterStor customers

Page 6: HPC’s most Intelligent Storage Solution193.62.125.70/CIUK2017/Cray.pdf · 2018. 2. 6. · 11 Mira BlueGene/Q, Power BQC 16C 1.60GHz, Custom GPFS 28.8 240 12 Stampede2 Dell PowerEdge

6

ClusterStor L300 Platform

• Lustre 2.7

• 12 Gbit SAS enclosures

• Broadwell based ESMs*

• EDR IB

• OPA

• 100 GbE

• 2x 40 GbE

• 6/8/10 TB HDDs

• 3.2 TB SSDs

• NXD** I/O Manager

• Advanced MMU*** (option)

Few applications with large,

sequential I/O workloads

ClusterStor L300

Many applications with

mixed I/O workloads

ClusterStor L300N

Price Difference:

15 - 20%

• Lustre 2.7

• 6 Gbit SAS enclosures

• Haswell based ESMs

• EDR IB

• OPA

• 100 GbE

• 2x 40 GbE

• 6/8/10 TB HDDs

* Embedded Server Module

** Nondisruptive aXeleration of Data

*** Metadata Management Unit

Copyright Cray, Inc. 2017

Page 7: HPC’s most Intelligent Storage Solution193.62.125.70/CIUK2017/Cray.pdf · 2018. 2. 6. · 11 Mira BlueGene/Q, Power BQC 16C 1.60GHz, Custom GPFS 28.8 240 12 Stampede2 Dell PowerEdge

7

• 5U84 Enclosure – completely HA

• Two trays of 42 HDD’s redundantly SAS connected

• Dual-ported 3.5” NL SAS & SSD HDD Support

• 300+ MB/s SAS available bandwidth per HDD

• Pair of HA Embedded Server Modules

• L300 = up to 10 GB/sec IOR over IB - Sustained

• IB EDR, Intel OPA or 2x40 or 100 GbE Network Link

• Support for Lustre®

• 2x SSD OSS Journal/WIB disks for increased perf

• Data Protection/Integrity (GridRAID, 41 drives)

• GridRAID - 2 OSS’s per SSU, 1 OST’s per OSS

• 4/6/8/10 TB drives supported

Scalable Storage Unit (SSU)

Embedded

Server Modules

Copyright Cray, Inc. 2017

Page 8: HPC’s most Intelligent Storage Solution193.62.125.70/CIUK2017/Cray.pdf · 2018. 2. 6. · 11 Mira BlueGene/Q, Power BQC 16C 1.60GHz, Custom GPFS 28.8 240 12 Stampede2 Dell PowerEdge

8

GridRAID - Faster Time to Recovery

To Lustre Client

Network (IB or 40GbE)

OST #2

Grid Raid

41 DrivesObject

Storage

Server #2

SAS Connectivity Lustre Connectivity

OST #1

Grid Raid

41 DrivesObject

Storage

Server #1

Key Product Advantage

› Up to 4x faster HDD Recovery time

› GridRAID = Parity Declustered RAID

o Parity de-clustering is designed to

balance cost against data reliability and

performance during failure recovery.

o It improves on standard parity

organizations by reducing the additional

load on surviving disks during the

reconstruction of a failed disk’s

contents.

o Yields higher user throughput during

recovery, and/or shorter recovery time.

Copyright Cray, Inc. 2017

Page 9: HPC’s most Intelligent Storage Solution193.62.125.70/CIUK2017/Cray.pdf · 2018. 2. 6. · 11 Mira BlueGene/Q, Power BQC 16C 1.60GHz, Custom GPFS 28.8 240 12 Stampede2 Dell PowerEdge

9

Dataflow – Platform 300

EDR IB100GbE

Haswell L300/Broadwell

L300N

12Gbps SASCtrl

12GbpsExpander

~10GB/s

~12.5GB/s Required(8+2+2 Grid-RAID)

~12-13GB/s

x16 PCIe

x16 PCIe

x8 PCIe x4

x8

x4

x4

x4

~13GB/s

E

E

E

45GB/s (4.5x)Raw = 68GB/s

~4.3GB/s

300MB/s per drive

x14

x14

x14

x2

(x12 to other drawer)

DDR

Copyright Cray, Inc. 2017

Page 10: HPC’s most Intelligent Storage Solution193.62.125.70/CIUK2017/Cray.pdf · 2018. 2. 6. · 11 Mira BlueGene/Q, Power BQC 16C 1.60GHz, Custom GPFS 28.8 240 12 Stampede2 Dell PowerEdge

10

• ClusterStor has Pioneered 10x Performance Improvement in HPC Storage in the last 5 Years

Efficiency @ Scale: HDD Performance

0%

10%

20%

30%

40%

50%

60%

70%

80%

90%

2011ORNL

2013NCSA

2014Kaust

2015DKRZ

2016CEA

2017CS 300N

Efficiency GAP

Realized HDD Performance in HPC Storage Systems

ClusterStor has delivered the fastest and most efficient HPC storage systems in the world

File System

Performance

per HDD

vs.

Single HDD Max

Raw Performance =

Efficiency Gap

83%

Efficiency

delivered

with L300N

---

244 MB/s per

drive

Copyright Cray, Inc. 2017

Page 11: HPC’s most Intelligent Storage Solution193.62.125.70/CIUK2017/Cray.pdf · 2018. 2. 6. · 11 Mira BlueGene/Q, Power BQC 16C 1.60GHz, Custom GPFS 28.8 240 12 Stampede2 Dell PowerEdge

11

ClusterStor: No Single Points Of Failure

Copyright Cray, Inc. 2017

Page 12: HPC’s most Intelligent Storage Solution193.62.125.70/CIUK2017/Cray.pdf · 2018. 2. 6. · 11 Mira BlueGene/Q, Power BQC 16C 1.60GHz, Custom GPFS 28.8 240 12 Stampede2 Dell PowerEdge

12

High Availability Meta Data Server

Performance for Thousands of

Compute Clients

High Availability MGMT Servers

Health and Performance

High Availability

Capacity Expansion

Lower Price per PB +

Performance

High Availability Data Network

Provides Compute Clients an

Alternative Data Path to the

Storage Servers & HDD/SSD

High Availability System

Management Network

Eliminates Single Points

of Failure

Factory Integration and Test

Faster Time to Acceptance and

Production

File System & Linux OS

Integration

100’s of SW Improvements +

Test Validation

De-clustered Parity RAID

Faster Time to Recovery &

Higher Data Resiliency

Modular Performance +

Capacity Building Blocks

Balanced I/O up to TB/sec

Disk Health Monitoring

& Management

Faster Time to Repair

High Availability Storage Servers

Failover / Failback Monitoring

and Management

Custom SAS Performance

Accelerator

Provides additional HDD

performance of up to 12GB/sec

per enclosure module

Copyright Cray, Inc. 2017

Complexity – Managed behind the scenes

Page 13: HPC’s most Intelligent Storage Solution193.62.125.70/CIUK2017/Cray.pdf · 2018. 2. 6. · 11 Mira BlueGene/Q, Power BQC 16C 1.60GHz, Custom GPFS 28.8 240 12 Stampede2 Dell PowerEdge

13

ClusterStor: Monitoring & Reporting

SNMP

Email

REST

API

Guided

FRU

Repair

Nagios

Copyright Cray, Inc. 2017

Page 14: HPC’s most Intelligent Storage Solution193.62.125.70/CIUK2017/Cray.pdf · 2018. 2. 6. · 11 Mira BlueGene/Q, Power BQC 16C 1.60GHz, Custom GPFS 28.8 240 12 Stampede2 Dell PowerEdge

14

ClusterStor: ClusterStor Manager

Copyright Cray, Inc. 2017

Page 15: HPC’s most Intelligent Storage Solution193.62.125.70/CIUK2017/Cray.pdf · 2018. 2. 6. · 11 Mira BlueGene/Q, Power BQC 16C 1.60GHz, Custom GPFS 28.8 240 12 Stampede2 Dell PowerEdge

15

ClusterStor: Linear Scalability

Unique converged architecture that adds with each modular building block

compute/memory/network/SSD/HDD resources for linear performance at scale.

Capacity (raw)

in PB

Performance (IOR) in GB/sec on EDR

10 20 30 40 60 70 80 90 100

820

1640

2460

4100

3280

4920

5740

7380

6560

ClusterStor L300 with 10TB HDDs

Copyright Cray, Inc. 2017

Page 16: HPC’s most Intelligent Storage Solution193.62.125.70/CIUK2017/Cray.pdf · 2018. 2. 6. · 11 Mira BlueGene/Q, Power BQC 16C 1.60GHz, Custom GPFS 28.8 240 12 Stampede2 Dell PowerEdge

16

L300N

Page 17: HPC’s most Intelligent Storage Solution193.62.125.70/CIUK2017/Cray.pdf · 2018. 2. 6. · 11 Mira BlueGene/Q, Power BQC 16C 1.60GHz, Custom GPFS 28.8 240 12 Stampede2 Dell PowerEdge

17

ClusterStor L300N: Problem Statement

1. Many compute applications

on the same storage platform› Mixed I/O patterns - Random, unaligned,

strided, small, large, sequential I/O

2. End of Dennard scaling› Leads to exploding core counts

› Making the mixed I/O problem worse

3. Fast HPC storage needs to

be more than “Scratch”› Home/project directories

› Storage for analytics workloads

Ways to solve

this mixed

I/O workload

problem

I/O workloads are becoming increasingly unpredictable for the HPC storage system

Over provision with

additional storage

servers & disk drives

Buy expensive

All Flash Arrays

Deploy the new

ClusterStor L300N

solution

$$$

$$$

$

Copyright Cray, Inc. 2017

Page 18: HPC’s most Intelligent Storage Solution193.62.125.70/CIUK2017/Cray.pdf · 2018. 2. 6. · 11 Mira BlueGene/Q, Power BQC 16C 1.60GHz, Custom GPFS 28.8 240 12 Stampede2 Dell PowerEdge

18

Challenge: Lost

Productivity Due To Poor

I/O Predictability

Solution: Smart I/O

Management Provides

Consistent Performance

Result: I/O Optimized For

Each Application I/O

Profile

Compute Cluster ApplicationsSensor Data Capture & Processing

Data mining - Simulations

Modelling - Software development

Visualization of complex data -

Rapid mathematical calculations

Mixed I/O Patterns=Unpredictable Application

Performance

Goal: Support Widest

Application I/O Variety Within

Budget

Random

Un - Aligned

Small Block

Sequential

ClusterStor NXD =Transparent Redirection of I/O to

Appropriate SSD or HDD Medium

ClusterStor NXD =Predictable and Fastest Compute

Application Time-to-Solution

ClusterStor L300N: Any Workload, Any Time

Copyright Cray, Inc. 2017

Page 19: HPC’s most Intelligent Storage Solution193.62.125.70/CIUK2017/Cray.pdf · 2018. 2. 6. · 11 Mira BlueGene/Q, Power BQC 16C 1.60GHz, Custom GPFS 28.8 240 12 Stampede2 Dell PowerEdge

19

SCSI Mid-Layer

sg

NXD DM Target Filter

Driver

Device Mapper / Mapping Target Interface

File Systems (ldiskfs or NSD)

Virtual File System (Lustre or Spectrum Scale)

System I/O Call Interface

NXD

Caching Library

sx sd st sb sz••••••

NXD Low-Level Driver

SSD partition HDD partition

≤ 32 KiB > 32 KiB

File system layer

I/O block layer

Device mapping

Hardware layer

NXD I/O Manager

– Filter driver implemented as

device mapper target driver

– Core library compiled as a

Linux kernel module with

well defined APIs

– Work at the block layer be

transparent to file system

and applications

– Core caching function is an

OS agnostic portable library

with well defined interfaces

– Filter Driver intercept’s IO

and routes through Cache

Management Library for

Caching functions

ClusterStor L300N NXD Software Architecture

Copyright Cray, Inc. 2017

Page 20: HPC’s most Intelligent Storage Solution193.62.125.70/CIUK2017/Cray.pdf · 2018. 2. 6. · 11 Mira BlueGene/Q, Power BQC 16C 1.60GHz, Custom GPFS 28.8 240 12 Stampede2 Dell PowerEdge

20

Basic Nytro IO Manager Data Path

Wri

te

ac

kn

ow

led

ged

SSD’s In Memory Spinning Media

Lustre or Spectrum Scale

Wri

te

ac

kn

ow

led

ged

OST/NSD Block Layer

Nytro Filter Driver Nytro Caching Lib

1. Incoming IO are profiled & filtered

2. Large IO to spindle & small to SSD

3. Write acknowledge once on media

4. Small IO’s coalesced & flushed to spindle

Copyright Cray, Inc. 2017

Page 21: HPC’s most Intelligent Storage Solution193.62.125.70/CIUK2017/Cray.pdf · 2018. 2. 6. · 11 Mira BlueGene/Q, Power BQC 16C 1.60GHz, Custom GPFS 28.8 240 12 Stampede2 Dell PowerEdge

21

NXD Operation & Block I/O Distribution Example

WRITE I/O HistoryBlock Sizes # Events

< 4K 0

4K 23978

4K+1 — 8K 499318

8K+1 — 16K 19954

16K+1 — 32K 1962

32K+1 — 64K 127

64K+1 — 128K 39

128K+1 — 256K 6

256K+1 — 512K 2

512K+1 — 1M 0

1M+1 — 2M 0

2M+1 — 4M 0

4M+1 — 8M 0

8M+1 — 16M 0

16M+1 — 32M 0

READ I/O HistoryBlock Sizes # Events

< 4K 0

4K 56796

4K+1 — 8K 456385

8K+1 — 16K 55

16K+1 — 32K 31

32K+1 — 64K 4

64K+1 — 128K 0

128K+1 — 256K 0

256K+1 — 512K 0

512K+1 — 1M 0

1M+1 — 2M 0

2M+1 — 4M 0

4M+1 — 8M 0

8M+1 — 16M 0

16M+1 — 32M 0

Copyright Cray, Inc. 2017

Page 22: HPC’s most Intelligent Storage Solution193.62.125.70/CIUK2017/Cray.pdf · 2018. 2. 6. · 11 Mira BlueGene/Q, Power BQC 16C 1.60GHz, Custom GPFS 28.8 240 12 Stampede2 Dell PowerEdge

22

0

10,000

20,000

30,000

40,000

50,000

60,000

70,000

80,000

90,000

1 2 4 8 16 32 64 128

IOP

S

Transfer Size (KB)

Write performance

L300N NXD – Write/Rewrite, Aligned I/O

16 nodes, 64 processes total, 1x SSU, (2x Koho ME vs. 82x 8TB MakaraBP)

0

10,000

20,000

30,000

40,000

50,000

60,000

70,000

80,000

90,000

1 2 4 8 16 32 64 128IO

PS

Transfer Size (KB)

Re-Write performance

NytroXD

GridRAID

with NDX

w/o NDX

Copyright Cray, Inc. 2017

Page 23: HPC’s most Intelligent Storage Solution193.62.125.70/CIUK2017/Cray.pdf · 2018. 2. 6. · 11 Mira BlueGene/Q, Power BQC 16C 1.60GHz, Custom GPFS 28.8 240 12 Stampede2 Dell PowerEdge

23

L300N NXD – Read performance16 nodes, 64 processes total, 1x SSU, (2x Koho ME vs. 82x 8TB MakaraBP)

0

20,000

40,000

60,000

80,000

100,000

120,000

140,000

160,000

180,000

200,000

1 2 4 8 16 32 64 128

IOP

S

Transfer Size (KB)

Aligned I/O

0

20,000

40,000

60,000

80,000

100,000

120,000

140,000

160,000

180,000

200,000

5 10 20 40 80 160

IOP

S

Transfer Size (KB)

Unligned I/O

NytroXD

GridRAID

with NDX

w/o NDX

Copyright Cray, Inc. 2017

Page 24: HPC’s most Intelligent Storage Solution193.62.125.70/CIUK2017/Cray.pdf · 2018. 2. 6. · 11 Mira BlueGene/Q, Power BQC 16C 1.60GHz, Custom GPFS 28.8 240 12 Stampede2 Dell PowerEdge

24

L300N – IOPS Performance

IOR-2.10.3

*Stonewalling (180 sec)

Preconditioned for random workload

Optimal client/server settings

Write Initial Write Update Read

Peak* L300N 45,000 IOPS 60,000 IOPS 200,000 IOPS

L300 2,800 IOPS 3,500 IOPS 21,000 IOPS

Write Initial Read

Sustained L300N 25,000 IOPS 110,000 IOPS

L300 < 2,000 IOPS < 15,000 IOPS

Performance per SSU (4KiB IOPS)

Write Sparse- Random Sparse Write

Write Update - Random Rewrite (overwrite)

Read - Random Read

Copyright Cray, Inc. 2017

Page 25: HPC’s most Intelligent Storage Solution193.62.125.70/CIUK2017/Cray.pdf · 2018. 2. 6. · 11 Mira BlueGene/Q, Power BQC 16C 1.60GHz, Custom GPFS 28.8 240 12 Stampede2 Dell PowerEdge

25

ClusterStor and Lustre 2.7 DNE Hardware• DNE is a Hardware OPTION in ClusterStor v3.0 using Standard MMU

• No changes to base rack MDS/MGT Server configuration MMU Configuration

• Base MMU is configured with MDT0 has master and MDT1 has additional MDT via DNE

• DNE Servers are configured in active / active pairs

• ClusterStor 2U24 with 2 MDS embedded server modules using the same standard MMU

• Scale Metadata Capacity / Performance with DNE Server pairs via MMU

• Up to 8 additional DNE MDS server pair chassis supported per file system (up to 8 additional MMUs)

• 2 to 18 MDS/MDT supported per file system Max

Root

dir a

File

MDT0

dir b

dir b2

File

MDT1

dir c

dir c2

File

MDT2

dir d

dir d2

File

MDT3

dir e

dir e2

File

MDT4

dir f

dir f2

File

MDT5

Base MMU

Copyright Cray, Inc. 2017

Page 26: HPC’s most Intelligent Storage Solution193.62.125.70/CIUK2017/Cray.pdf · 2018. 2. 6. · 11 Mira BlueGene/Q, Power BQC 16C 1.60GHz, Custom GPFS 28.8 240 12 Stampede2 Dell PowerEdge

26

MMU-Advanced Performance

• Single MDS/MDT

• 2x SSU+1 (32 OSTs)

• RAID10 (5+5)

• mdtest-1.9.3

• Reporting File/s

MDS Create Stat Open Remove

MMU - Standard 55K 220K 95K 70K

MMU - Advanced 105K 350K 220K 80K

Copyright Cray, Inc. 2017

Page 27: HPC’s most Intelligent Storage Solution193.62.125.70/CIUK2017/Cray.pdf · 2018. 2. 6. · 11 Mira BlueGene/Q, Power BQC 16C 1.60GHz, Custom GPFS 28.8 240 12 Stampede2 Dell PowerEdge

27

What makes NXD a better choice ?

• Fully transparent I/O acceleration solution

• No changes for applications, tools, scripts, operators and users

• Standard Lustre Clients

• No custom libraries, no FUSE, no recompile etc.

• NXD cache size scales with filesystem size• Best balance of capacity and value

• Full data integrity

• GridRAID

• Network checksums

• T10-PI

• Easily augmented with future All Flash Arrays

• OST pool deployment

ClusterStor L300N

Copyright Cray, Inc. 2017

Page 28: HPC’s most Intelligent Storage Solution193.62.125.70/CIUK2017/Cray.pdf · 2018. 2. 6. · 11 Mira BlueGene/Q, Power BQC 16C 1.60GHz, Custom GPFS 28.8 240 12 Stampede2 Dell PowerEdge

28

Summary: ClusterStor Value PropositionPerformance Efficiency

Highest performance throughput per storage device.

Less hardware needed to

achieve performance requirement

Engineered Solution Pre-integrated, tested,

tuned, and shipped ready to

deploy.

Days instead of weeks

to implementation

ReliabilityNo single point of failure

architecture

Less rebuilds and less

downtime

ScalabilitySustained linear performance

when adding capacity

Predictable application

performance

Enterprise-grade Management

and SupportComprehensive file system management,

RAS/Phone home, holistic hardware

monitoring with health alerts, API

Less downtime and Faster-Time-To-

Problem Resolution

Five

Unique

Solution

Values

1

2

34

5

Copyright Cray, Inc. 2017

Page 29: HPC’s most Intelligent Storage Solution193.62.125.70/CIUK2017/Cray.pdf · 2018. 2. 6. · 11 Mira BlueGene/Q, Power BQC 16C 1.60GHz, Custom GPFS 28.8 240 12 Stampede2 Dell PowerEdge

29

Thank You