hpv diagnostic kits - biotech-iggbiotech-igg.com/media/hpv_diagnostics.pdfv11-100-r0,2-ce 6/11 fep...

1
all kits are certified str. 4 Clinical sample Amplification results Interpretation Interpretation correctness Without epithelial cells IC–, HPV– incorrect sample With few epithelial cells IC±, HPV± incorrect sample or highly positive Sufficient IC+, HPV+ HPV positive Clinical sample Amplification results Interpretation Interpretation correctness Without epithelial cells IC+, HPV– HPV negative With few epithelial cells IC+, HPV± HPV negative or slightly positive Sufficient IC+, HPV+ HPV positive Catalogue number Type Detection Tests R-V31-T-4x(RG,iQ,Mx)-CE QUANTITATIVE Real-Time 108 R-V31-T-2x(RG,iQ,Mx)-CE QUANTITATIVE Real-Time 108 R-V25(RG,iQ,Mx)-CE genotyping Real-Time 108 R-V12(RG,iQ,Mx)-CE 16/18 Real-Time 108 V31-FEP-CE screen FEP 120 V31-3x-FEP-CE screen FEP 120 V31-100F-CE screen Elfo 110 V25-50F-CE genotyping Elfo 55 Catalogue number Type Detection Tests R-V11(RG,iQ,Mx)-CE 6/11 Real-Time 120 V11-100-R0,2-CE 6/11 FEP 110 HPV diagnostic kits the most sensitive screening – early diagnostics of cervical pre-cancer and cancer TaqMan ® based, open for various cyclers – Rotor-Gene Q (Qiagen), iCycler iQ (Bio-Rad), Mx3000P (Stratagene), SmartCycler (Cepheid), ABI ® 7300/7500/StepOne and many others detection with quantification of HPV viral load (per 10 5 cells) – perfect for ranging of the pacient risk exact genotyping – HPV HCR types: 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59 evaluation of clinical sample quality – elimination of false negative results internal control based on human β-globin gene detection distinction between clinically relevant and irrelevant HPV quantities (per 10 5 human cells) Special kits features Example 1: Kit with standard internal control DNA (external IC) Example 2: Kit with internal control based on human β-globin gene detection www.pcrdiagnostics.eu [email protected] tel.: +421 264 789 336 fax: +421 264 789 040 High-Risk HPV kits Low-Risk HPV kits When interpreting results, only our kits allow to evaluate also sample quality

Upload: vuquynh

Post on 28-May-2018

219 views

Category:

Documents


0 download

TRANSCRIPT

all kits are certifi ed

str. 4

Clinical sampleAmplifi cation

resultsInterpretation

Interpretation

correctness

Without epithelial cells IC–, HPV– incorrect sample

With few epithelial cells IC±, HPV±incorrect sample

or highly positive

Suffi cient IC+, HPV+ HPV positive

Clinical sampleAmplifi cation

resultsInterpretation

Interpretation

correctness

Without epithelial cells IC+, HPV– HPV negative

With few epithelial cells IC+, HPV±HPV negative

or slightly positive

Suffi cient IC+, HPV+ HPV positive

Catalogue number Type Detection Tests

R-V31-T-4x(RG,iQ,Mx)-CE QUANTITATIVE Real-Time 108

R-V31-T-2x(RG,iQ,Mx)-CE QUANTITATIVE Real-Time 108

R-V25(RG,iQ,Mx)-CE genotyping Real-Time 108

R-V12(RG,iQ,Mx)-CE 16/18 Real-Time 108

V31-FEP-CE screen FEP 120

V31-3x-FEP-CE screen FEP 120

V31-100F-CE screen Elfo 110

V25-50F-CE genotyping Elfo 55

Catalogue number Type Detection Tests

R-V11(RG,iQ,Mx)-CE 6/11 Real-Time 120

V11-100-R0,2-CE 6/11 FEP 110

HPV diagnostic kitsthe most sensitive screening – early diagnostics of cervical pre-cancer and cancer

TaqMan® based, open for various cyclers – Rotor-Gene Q (Qiagen), iCycler iQ (Bio-Rad), Mx3000P

(Stratagene), SmartCycler (Cepheid), ABI® 7300/7500/StepOne and many others

detection with quantifi cation of HPV viral load (per 105 cells) – perfect

for ranging of the pacient risk

exact genotyping – HPV HCR types: 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59

evaluation of clinical sample quality – elimination of false negative results

internal control based on human β-globin gene detection

distinction between clinically relevant and irrelevant HPV quantities (per 105 human cells)

Special kits features

Example 1: Kit with standard internal control DNA (external IC)

Example 2: Kit with internal control based on human β-globin gene detection

www.pcrdiagnostics.eu • [email protected] • tel.: +421 264 789 336 • fax: +421 264 789 040

High-Risk

HPV

kits

Low-Risk

HPV

kits

When interpreting results, only our kits allow to evaluate also sample quality