htc abb low voltage products - hightech.com.au

24
HTC ABB Low Voltage Products

Upload: others

Post on 01-Jun-2022

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: HTC ABB Low Voltage Products - hightech.com.au

—HTCABB Low Voltage Products

Page 2: HTC ABB Low Voltage Products - hightech.com.au
Page 3: HTC ABB Low Voltage Products - hightech.com.au

2 Residential products

3 Miniature circuit breakers

4 Auxiliary elements and accessories

5 Consumer units, load centres and distribution boards

6 Manual motor starters

8 3-pole contactors

10 Thermal overload relays

13 Pluggable interface relays

15 Timers, monitoring relays and power supplies

18 Pushbuttons

19 Pilot lights with integrated LED

20 Insulating enclosures and enclosures for automation

— Table of contents

Page 4: HTC ABB Low Voltage Products - hightech.com.au

HTC STOCK

2 HTC A B B O FFER I N G

SHD 201 SHD 202 SHD 203 SHD 204

—Residential productsSwitch disconnectors

—Switch disconnectors

Rating Order code

Standard (A) 1 Pole 2 Pole 3 Pole 4 Pole

AS/NZS 60947.3, 25 SHD20125 SHD20225 SHD20325 SHD20425

IEC/EN 60947-3 32 SHD20132 SHD20232 SHD20332 SHD20432

Voltage range 40 SHD20140 SHD20240 SHD20340 SHD20440

230/400 V 63 SHD20163 SHD20263 SHD20363 SHD20463

80 E20180RD E20280RD E20380RD E20480RD

100 E201100RD E202100RD E203100RD E204100RD

125 E201125RD E202125RD E203125RD E204125RD

Switch disconnectors• Suitable for under load operation• Sealable toggle to lock in either OFF or ON posi-

tion• Red toggle for easy identification• Ideal for consumer units, load centres and small

distribution boards

Page 5: HTC ABB Low Voltage Products - hightech.com.au

HTC STOCK

LOW VO LTAG E PR O D U C TS 3

—Miniature circuit breakers (MCB) 6kA commercial and industrial range

C-Curve Description Order code

Standard Rating (A) 1 Pole 2 Pole 3 Pole 4 Pole

AS/NZS 60898, 0.5 MCB 6kA 0.5A C-curve S201C0.5 S202C0.5 S203C0.5 S204C0.5

IEC/EN 60898, 1 MCB 6kA 1A C-curve S201C1 S202C1 S203C1 S204C1

AS/NZS60947, 1.6 MCB 6kA 1.6A C-curve S201C1.6 S202C1.6 S203C1.6 S204C1.6

IEC/EN60947 2 MCB 6kA 2A C-curve S201C2 S202C2 S203C2 S204C2

Rated short circuit capacity Icn 3 MCB 6kA 3A C-curve S201C3 S202C3 S203C3 S204C3

6kA 4 MCB 6kA 4A C-curve S201C4 S202C4 S203C4 S204C4

Voltage range 6 MCB 6kA 6A C-curve S201C6 S202C6 S203C6 S204C6

1P: 230 – 240 V AC, 72 V DC 8 MCB 6kA 8A C-curve S201C8 S202C8 S203C8 S204C8

(DC rating to 63 A only) 10 MCB 6kA 10A C-curve S201C10 S202C10 S203C10 S204C10

2 – 4P: 440 V AC, 125 V DC 13 MCB 6kA 13A C-curve S201C13 S202C13 S203C13 S204C13

(DC rating to 63 A only) 16 MCB 6kA 16A C-curve S201C16 S202C16 S203C16 S204C16

20 MCB 6kA 20A C-curve S201C20 S202C20 S203C20 S204C20

25 MCB 6kA 25A C-curve S201C25 S202C25 S203C25 S204C25

32 MCB 6kA 32A C-curve S201C32 S202C32 S203C32 S204C32

40 MCB 6kA 40A C-curve S201C40 S202C40 S203C40 S204C40

50 MCB 6kA 50A C-curve S201C50 S202C50 S203C50 S204C50

63 MCB 6kA 63A C-curve S201C63 S202C63 S203C63 S204C63

80 MCB 6kA 80A C-curve S201C80 S202C80 S203C80 S204C80

100 MCB 6kA 100A C-curve S201C100 S202C100 S203C100 S204C100

B, K and Z curves available on request

D-Curve Description Order code

Rating (A) 1 Pole 2 Pole 3 Pole 4 Pole

0.5 MCB 6kA 0.5A D-curve S201D0.5 S202D0.5 S203D0.5 S204D0.5

1 MCB 6kA 1A D-curve S201D1 S202D1 S203D1 S204D1

1.6 MCB 6kA 1.6A D-curve S201D1.6 S202D1.6 S203D1.6 S204D1.6

2 MCB 6kA 2A D-curve S201D2 S202D2 S203D2 S204D2

3 MCB 6kA 3A D-curve S201D3 S202D3 S203D3 S204D3

4 MCB 6kA 4A D-curve S201D4 S202D4 S203D4 S204D4

6 MCB 6kA 6A D-curve S201D6 S202D6 S203D6 S204D6

8 MCB 6kA 8A D-curve S201D8 S202D8 S203D8 S204D8

10 MCB 6kA 10A D-curve S201D10 S202D10 S203D10 S204D10

13 MCB 6kA 13A D-curve S201D13 S202D13 S203D13 S204D13

16 MCB 6kA 16A D-curve S201D16 S202D16 S203D16 S204D16

20 MCB 6kA 20A D-curve S201D20 S202D20 S203D20 S204D20

25 MCB 6kA 25A D-curve S201D25 S202D25 S203D25 S204D25

32 MCB 6kA 32A D-curve S201D32 S202D32 S203D32 S204D32

40 MCB 6kA 40A D-curve S201D40 S202D40 S203D40 S204D40

50 MCB 6kA 50A D-curve S201D50 S202D50 S203D50 S204D50

63 MCB 6kA 63A D-curve S201D63 S202D63 S203D63 S204D63

B, K and Z curves available on request

S 202 S 201 S 203

—Miniature circuit breakersS200

Miniature circuit breakers (MCB) 6kA commercial and industrial range• Protection against overloads and short circuits• Ideally suited for commercial and industrial applications in

consumer units, load centres and distribution boards• Suits the range of System pro M accessories

Page 6: HTC ABB Low Voltage Products - hightech.com.au

HTC STOCK

4 HTC A B B O FFER I N G

—Pre-assembled busbar systems (not to be cut)

Phases Number Cross Amps Suits Order codeof pins section

1 12 10 mm2 63 SH200, S200, DSE201, DS271 PS1/12

3 12 10 mm2 63 SH200, S200, DSE201, DS271 PS3/12

—Busbar systems suitable to be cut to length

Phases Number Cross Amps Suits End cap Order codeof pins section

1 4 10 mm2 63 SH200, S200, SD200, DSE201, – PS1/4

1 12 10 mm2 63 DSE201M – PS1/12N

1 60 10 mm2 63 PS-END 0 PS1/60

1 60 16 mm2 80 PS-END 0 PS1/60/16

1 12 10 mm2 63 SN201, DSN201 – BS91/12

1 12 10 mm2 63 – BS91/12NA

1 56 10 mm2 63 – BS91/56

2 12 10 mm2 63 SH200, S200, SD200, PS-END PS2/12

2 58 10 mm2 63 DSE201, DSE201M PS-END PS2/58

2 58 16 mm2 80 PS-END PS2/58/16

3 6 10 mm2 63 – PS3/6

3 60 10 mm2 63 PS-END PS3/60

3 60 16 mm2 80 PS-END PS3/60/16

3 12 10 mm2 63 – BS93/12

3 57 10 mm2 63 SN201, DSN201 BS9-END 3P BS93/57

3 24 60 mm2 125 S800 S800-END S803-BB250

—Busbar system end caps

Description Suits Order code

End cap for busbar PS2/** and PS3/** PS-END

End cap for busbar PS1/** PS-END0

End cap for busbar BS93/** BS9-END3P

End cap for busbar S803-BB250 S800-END

—Insulated terminals (feed-in terminals for busbars)

Connection Type of Terminal lug Current rating Suits Order codecapacity connection L (mm) (A) busbar type

25 pin 15 80 BS9 FEED-IN25/151P

25 pin 30 80 BS9 FEED-IN25/303P

6 - 50 pin 15 125 PS AST50/15

6 - 50 pin 15 125 PS AST50/15Q

6 - 50 pin 32 125 PS AST50/32Q

—Feeder terminal - single pole, can be mounted side by side to create multipole terminal for busbars

Connection Current rating Order codecapacity (A)

6 - 35 100 SZESK2

6 - 50 125 SZESK3

PS 3/6 - PS 3/12

AST 50/32 Q

SZ-ESK 2

—Auxiliary elements and accessories Busbar systems

Page 7: HTC ABB Low Voltage Products - hightech.com.au

HTC STOCK

LOW VO LTAG E PR O D U C TS 5

Hybrid chassis for high performance circuit breakersFor use with S800 high performance circuit breakers. The hybrid chassis arrangement pro-vides 6 poles of 27mm pitch with the balance available in the conventional 17.5mm. Also available are complete chassis in the 27mm pitch for 250A and 400A. CMP chassis are available as a top feed as standard. Bottom feed and universal feed is available as indent.

Technical data• 250A and 400A• Type tested to AS3439.1, 20kA, 0.1sec (250A). 20kA, 0.2sec (400A)• Chassis suitable for S800 high performance circuit breakers• Splayed busbar for incomer connections• Tee offs stripped and 100% capped• Improved insulation capability

— Hybrid chassis for high performance breakers with 6 poles @ 27mm (S800)

Total pole capacity Current Pole capacity Order coderating 27mm pitch 17.8mm pitch

18 pole 250A 6 12 CMP2506H12TF

24 pole 250A 6 18 CMP2506H18TF

36 pole 250A 6 30 CMP2506H30TF

48 pole 250A 6 42 CMP2506H42TF

18 pole 400A 6 12 CMP4006H12TF

24 pole 400A 6 18 CMP4006H18TF

36 pole 400A 6 30 CMP4006H30TF

48 pole 400A 6 42 CMP4006H42TF

— Chassis for high performance breakers with total capacity @ 27mm (S800)

Total pole capacity Current Pole capacity Order coderating 27mm pitch

12 pole 250A 12 CMP25012TF

18 pole 250A 18 CMP25018TF

12 pole 400A 12 CMP40012TF

18 pole 400A 18 CMP40018TF

Note: Larger pole capacities available on request

— Earth and neutral bars (mounting feet included)• 165 A• 2 x MB studs• 2 screw• Accepts 16mm2 ferruled cable

Description Order code165A 250A

E & N Bar 12 way EN12 EN25012

18 way EN18 EN25018

24 way EN24 EN25024

36 way EN36 EN25036

42 way EN42 EN25042

48 way EN48 EN25048

60 way EN60 EN25060

72 way EN72 EN25072

84 way EN84 EN25084

96 way EN96 EN25096

6 x M10 studs NB6S

—Consumer units, load centres and distribution boardsMiniature circuit breaker chassis

Page 8: HTC ABB Low Voltage Products - hightech.com.au

HTC STOCK

6 HTC A B B O FFER I N G

MS132-10

MS132-32

DescriptionMS132 is a compact and powerful range for motor protection up 15.5 kW (400 V) / 32 A in width of 45 mm. This type has also a clear and reliable indication of fault in a separate window in the event of short-circuit tripping. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorised changes. Auxiliary con-tacts, signaling contacts, undervoltage releases, shunt trips, three-phase bus bars, power in-feed blocks.

—Ordering details

Rated operational power400 V AC-3

Setting range

Short-circuit breakingcapacity ICS at 400 V AC

Rated instantaneous short-circuit current setting li

Factory code Order code

kW A kA A

0.03 0.10 … 0.16 100 1.56 1SAM350000R1001 MS132-0.16

0.06 0.16 … 0.25 100 2.44 1SAM350000R1002 MS132-0.25

0.09 0.25 … 0.40 100 3.90 1SAM350000R1003 MS132-0.4

0.12 0.40 … 0.63 100 6.14 1SAM350000R1004 MS132-0.63

0.25 0.63 … 1.00 100 11.50 1SAM350000R1005 MS132-1.0

0.55 1.00 … 1.60 100 18.40 1SAM350000R1006 MS132-1.6

0.75 1.60 … 2.50 100 28.75 1SAM350000R1007 MS132-2.5

1.5 2.50 … 4.00 100 50.00 1SAM350000R1008 MS132-4.0

2.2 4.00 … 6.30 100 78.75 1SAM350000R1009 MS132-6.3

4.0 6.30 … 10.0 100 150 1SAM350000R1010 MS132-10

5.5 8.00 … 12.0 100 180 1SAM350000R1012 MS132-12

7.5 10.0 … 16.0 100 240 1SAM350000R1011 MS132-16

9.0 16.0 … 20.0 100 300 1SAM350000R1013 MS132-20

12.5 20.0 … 25.0 50 375 1SAM350000R1014 MS132-25

15.5 25.0 … 32.0 25 480 1SAM350000R1015 MS132-32

Note:For full selection and technical details, please refer to main Manual motor starters catalogue 1SBC100192C0206. Manual motor starters should always be selected so that the actual motor current is within the setting range.

—MS132 manual motor starters0.10 to 32 A – with thermal and electromagnetic protection

Page 9: HTC ABB Low Voltage Products - hightech.com.au

HTC STOCK

LOW VO LTAG E PR O D U C TS 7

DescriptionMS165 is a compact and powerful range for motor protection up to 30 kW (400 V) / 65 A in width of 55 mm. This type has also a clear and reliable indication of fault in a separate win-dow in the event of short-circuit tripping. Further features are the build-in disconnect func-tion, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorised changes. Auxiliary con-tacts, signaling contacts, undervoltage releases, shunt trips, power in-feed blocks are avail-able as accessory. These are suitable throughout the MS116/MS132/MS165-range.

—Ordering details

Rated operational power400 V AC-3

Setting range

Short-circuit breakingcapacity ICS at 400 V AC

Rated instantaneous short-circuit current setting li

Factory code Order code

kW A kA A

7.5 10 ... 16 100 240 1SAM451000R1011 MS165-16

7.5 14 ... 20 100 300 1SAM451000R1012 MS165-20

11 18 ... 25 100 375 1SAM451000R1013 MS165-25

15 23 ... 32 75 480 1SAM451000R1014 MS165-32

22 30 ... 42 25 630 1SAM451000R1015 MS165-42

22 40 ... 54 25 810 1SAM451000R1016 MS165-54

30 52 ... 65 25 975 1SAM451000R1017 MS165-65

Note:For full selection and technical details, please refer to main Manual motor starters catalogue 1SBC100192C0206. Manual motor starters should always be selected so that the actual motor current is within the setting range.

2CD

C24

100

4V

00

15

MS165-65

—MS165 manual motor starters10 to 65 A – with thermal and electromagnetic protection

Page 10: HTC ABB Low Voltage Products - hightech.com.au

HTC STOCK

8 HTC A B B O FFER I N G

DescriptionAF09 ... AF38 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC. These contactors are of the block type design with 3 main poles.• control circuit: AC or DC operated with electronic coil interface accepting a wide control volt-

age range (e.g. 100...250 V AC and DC), only 4 control voltage ranges covering 24...500 V 50/60 Hz and 20...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening.

• built-in surge suppression• add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.

IEC Rated Rated control voltage UC Auxiliary contacts fitted

Factory code Order code

Power400 V AC-3

Current θ ≤ 40 °C AC-1 50/60 Hz

kW A V AC V DC

4 25 24…60 20…60 1 0 1SBL137001R1110 AF09301011

24…60 20…60 0 1 1SBL137001R1101 AF09300111

48…130 48…130 1 0 1SBL137001R1210 AF09301012

48…130 48…130 0 1 1SBL137001R1201 AF09300112

100…250 100…250 1 0 1SBL137001R1310 AF09301013

100…250 100…250 0 1 1SBL137001R1301 AF09300113

250…500 250…500 1 0 1SBL137001R1410 AF09301014

250…500 250…500 0 1 1SBL137001R1401 AF09300114

5.5 28 24…60 20…60 1 0 1SBL157001R1110 AF12301011

24…60 20…60 0 1 1SBL157001R1101 AF12300111

48…130 48…130 1 0 1SBL157001R1210 AF12301012

48…130 48…130 0 1 1SBL157001R1201 AF12300112

100…250 100…250 1 0 1SBL157001R1310 AF12301013

100…250 100…250 0 1 1SBL157001R1301 AF12300113

250…500 250…500 1 0 1SBL157001R1410 AF12301014

250…500 250…500 0 1 1SBL157001R1401 AF12300114

7.5 30 24…60 20…60 1 0 1SBL177001R1110 AF16301011

24…60 20…60 0 1 1SBL177001R1101 AF16300111

48…130 48…130 1 0 1SBL177001R1210 AF16301012

48…130 48…130 0 1 1SBL177001R1201 AF16300112

100…250 100…250 1 0 1SBL177001R1310 AF16301013

100…250 100…250 0 1 1SBL177001R1301 AF16300113

250…500 250…500 1 0 1SBL177001R1410 AF16301014

250…500 250…500 0 1 1SBL177001R1401 AF16300114

11 45 24…60 20…60 0 0 1SBL237001R1100 AF26300011

48…130 48…130 0 0 1SBL237001R1200 AF26300012

100…250 100…250 0 0 1SBL237001R1300 AF26300013

250…500 250…500 0 0 1SBL237001R1400 AF26300014

15 50 24…60 20…60 0 0 1SBL277001R1100 AF30300011

48…130 48…130 0 0 1SBL277001R1200 AF30300012

100…250 100…250 0 0 1SBL277001R1300 AF30300013

250…500 250…500 0 0 1SBL277001R1400 AF30300014

18.5 50 24…60 20…60 0 0 1SBL297001R1100 AF38300011

48…130 48…130 0 0 1SBL297001R1200 AF38300012

100…250 100…250 0 0 1SBL297001R1300 AF38300013

250…500 250…500 0 0 1SBL297001R1400 AF38300014

Other coil voltages and auxiliary contact arrangements available. For more detailed product information, please refer to the Technical Catalogue: 1SBC100192C0206

1) For 24...60 V 50/60 Hz - 20...60 V DC, use AF..-30-..-11 (see voltage code table). AF..-30-..-11 not suitable for direct control by PLC-output.

2) For direct PLC control, please contact ABB.

AF09-30-10

AF26-30-00

—AF09 ... AF38 3-pole contactors4 to 18.5 kW, AC / DC operated

Page 11: HTC ABB Low Voltage Products - hightech.com.au

HTC STOCK

LOW VO LTAG E PR O D U C TS 9

IEC Rated Rated control voltage UC Auxiliary contacts fitted

Factory code Order code

Power400 V AC-3

Current θ ≤ 40 °C AC-1 50 Hz 60 Hz

kW A V AC V DC

18.5 70 24...60 20...60 0 0 1SBL347001R1100 AF40300011

48...130 48...130 0 0 1SBL347001R1200 AF40300012

100...250 100...250 0 0 1SBL347001R1300 AF40300013

250...500 250...500 0 0 1SBL347001R1400 AF40300014

22 100 24...60 20...60 0 0 1SBL367001R1100 AF52300011

48...130 48...130 0 0 1SBL367001R1200 AF52300012

100...250 100...250 0 0 1SBL367001R1300 AF52300013

250...500 250...500 0 0 1SBL367001R1400 AF52300014

30 105 24...60 20...60 0 0 1SBL387001R1100 AF65300011

48...130 48...130 0 0 1SBL387001R1200 AF65300012

100...250 100...250 0 0 1SBL387001R1300 AF65300013

250...500 250...500 0 0 1SBL387001R1400 AF65300014

37 125 24...60 20...60 0 0 1SBL397001R1100 AF80300011

48...130 48...130 0 0 1SBL397001R1200 AF80300012

100...250 100...250 0 0 1SBL397001R1300 AF80300013

250...500 250...500 0 0 1SBL397001R1400 AF80300014

45 130 24...60 20...60 0 0 1SBL407001R1100 AF96300011

48...130 48...130 0 0 1SBL407001R1200 AF96300012

100...250 100...250 0 0 1SBL407001R1300 AF96300013

250...500 250...500 0 0 1SBL407001R1400 AF96300014

Other coil voltages and auxiliary contact arrangements available. For more detailed product information, please refer to the Technical Catalogue: 1SBC100192C0206

1) AF..-30-..-11 not suitable for direct control by PLC-output.2) For direct PLC control, please contact ABB.

DescriptionAF40 ... AF96 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC. AF80 and AF96 also suitable up to 1000 V AC applications. These contactors are of the block type design with 3 main poles.• control circuit: AC or DC operated with electronic coil interface accepting a wide control

voltage range (e.g. 100...250 V AC and DC), only 4 control voltage ranges cover-ing 24...500 V 50/60 Hz and 20...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening.

• built-in surge suppression• add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.

AF40-30-00

AF80-30-00

—AF40 ... AF96 3-pole contactors18.5 to 45 kW, AC / DC operated

Page 12: HTC ABB Low Voltage Products - hightech.com.au

HTC STOCK

10 HTC A B B O FFER I N G

—TF42 overload relay

Suitable for Contactors

AF09 …AF38

—Ordering details

Setting range A

Short-circuit protective device

Trip class Factory code Order code

0.10 ... 0.13 0.5 A, fuse type T 10 1SAZ721201R1005 TF42-0.13

0.13 ... 0.17 1.0 A, fuse type T 10 1SAZ721201R1008 TF42-0.17

0.17 ... 0.23 1.0 A, fuse type T 10 1SAZ721201R1009 TF42-0.23

0.23 ... 0.31 1.0 A, fuse type T 10 1SAZ721201R1013 TF42-0.31

0.31 ... 0.41 2.0 A, fuse type gG 10 1SAZ721201R1014 TF42-0.41

0.41 ... 0.55 2.0 A, fuse type gG 10 1SAZ721201R1017 TF42-0.55

0.55 ... 0.74 4.0 A, fuse type gG 10 1SAZ721201R1021 TF42-0.74

0.74 ... 1.00 6.0 A, fuse type gG 10 1SAZ721201R1023 TF42-1.0

1.00 ... 1.30 6.0 A, fuse type gG 10 1SAZ721201R1025 TF42-1.3

1.30 ... 1.70 10.0 A, fuse type gG 10 1SAZ721201R1028 TF42-1.7

1.70 ... 2.30 10.0 A, fuse type gG 10 1SAZ721201R1031 TF42-2.3

2.30 ... 3.10 10.0 A, fuse type gG 10 1SAZ721201R1033 TF42-3.1

3.10 ... 4.20 20.0 A, fuse type gG 10 1SAZ721201R1035 TF42-4.2

4.20 ... 5.70 20.0 A, fuse type gG 10 1SAZ721201R1038 TF42-5.7

5.70 ... 7.60 35.0 A, fuse type gG 10 1SAZ721201R1040 TF42-7.6

7.60 ... 10.0 35.0 A, fuse type gG 10 1SAZ721201R1043 TF42-10

10.0 ... 13.0 40.0 A, fuse type gG 10 1SAZ721201R1045 TF42-13

13.0 ... 16.0 40.0 A, fuse type gG 10 1SAZ721201R1047 TF42-16

16.0 ... 20.0 63.0 A, fuse type gG 10 1SAZ721201R1049 TF42-20

20.0 ... 24.0 63.0 A, fuse type gG 10 1SAZ721201R1051 TF42-24

24.0 ... 29.0 63.0 A, fuse type gG 10 1SAZ721201R1052 TF42-29

29.0 ... 35.0 80.0 A, fuse type gG 10 1SAZ721201R1053 TF42-35

35.0 ... 38.0/40.0 80.0 A, fuse type gG 10 1SAZ721201R1055 TF42-38

—Ordering details accessories

Suitable for Description Factory code Order code

TF42 Single mounting kit 1SAZ701902R0001 DB42

TF42 Reset push button 1SFA616162R1014 KPR3-101L

TF42 Remote reset coil 24-30 V AC/DC 1SAX101911R1001 DRS-F-01

TF42 Remote reset coil 48-60 V AC/DC 1SAX101911R1002 DRS-F-02

TF42 Remote reset coil 110-127 V AC/DC 1SAX101911R1003 DRS-F-03

TF42 Remote reset coil 220-240 V AC/DC 1SAX101911R1004 DRS-F-04

Note: For more detailed product information, please refer to the Technical Catalogue: 1SBC100192C0206

KPR3-101L

TF42 + DB42

DB42

TF42

—TF42 thermal overload relays0.10 to 38.0 A

Page 13: HTC ABB Low Voltage Products - hightech.com.au

HTC STOCK

LOW VO LTAG E PR O D U C TS 11

—TF65 overload relay

Suitable for Contactors

AF40 …AF65

—Ordering details

Setting range A

Short-circuit protective device

Trip class Factory code Order code

22.0 ... 28.0 80 A, gG Type Fuses 10 1SAZ811201R1001 TF65-28

25.0 ... 33.0 80 A, gG Type Fuses 10 1SAZ811201R1002 TF65-33

30.0 ... 40.0 100 A, gG Type Fuses 10 1SAZ811201R1003 TF65-40

36.0 ... 47.0 125 A, gG Type Fuses 10 1SAZ811201R1004 TF65-47

44.0 ... 53.0 125 A, gG Type Fuses 10 1SAZ811201R1005 TF65-53

50.0 ... 60.0 125 A, gG Type Fuses 10 1SAZ811201R1006 TF65-60

57.0 ... 67.0 160 A, gG Type Fuses 10 1SAZ811201R1007 TF65-67

—Ordering details accessories

Suitable for Description Factory code Order code

TF65 Single mounting kit 1SAZ801901R1001 DB65

Reset push button 1SFA616162R1014 KPR3-101L

TF65 Remote reset coil 24-30 V AC/DC 1SAX101911R1001 DRS-F-01

TF65 Remote reset coil 48-60 V AC/DC 1SAX101911R1002 DRS-F-02

TF65 Remote reset coil 110-127 V AC/DC 1SAX101911R1003 DRS-F-03

TF65 Remote reset coil 220-240 V AC/DC 1SAX101911R1004 DRS-F-04

Note: For more detailed product information, please refer to the Technical Catalogue: 1SBC100192C0206

TF65

DB65 DB65 mounted on TF65

KPR3-101L

—TF65 thermal overload relays22.0 to 67.0 A

Page 14: HTC ABB Low Voltage Products - hightech.com.au

HTC STOCK

12 HTC A B B O FFER I N G

—TF96 overload relay

Suitable for Contactors

AF80 …AF96

—Ordering details

Setting range A

Short-circuit protective device

Trip class Factory code Order code

40.0 ... 51.0 125 A, gG Type Fuses 10 1SAZ911201R1001 TF96-51

48.0 ... 60.0 160 A, gG Type Fuses 10 1SAZ911201R1002 TF96-60

57.0 ... 68.0 160 A, gG Type Fuses 10 1SAZ911201R1003 TF96-68

65.0 ... 78.0 200 A, gG Type Fuses 10 1SAZ911201R1004 TF96-78

75.0 ... 87.0 200 A, gG Type Fuses 10 1SAZ911201R1005 TF96-87

84.0 ... 96.0 250 A, gG Type Fuses 10 1SAZ911201R1006 TF96-96

—Ordering details accessories

Suitable for Description Factory code Order code

TF96 Single mounting kit 1SAZ901901R1001 DB96

Reset push button 1SFA616162R1014 KPR3-101L

TF96 Remote reset coil 24-30 V AC/DC 1SAX101911R1001 DRS-F-01

TF96 Remote reset coil 48-60 V AC/DC 1SAX101911R1002 DRS-F-02

TF96 Remote reset coil 110-127 V AC/DC 1SAX101911R1003 DRS-F-03

TF96 Remote reset coil 220-240 V AC/DC 1SAX101911R1004 DRS-F-04

Note: For more detailed product information, please refer to the Technical Catalogue: 1SBC100192C0206

DB96 DB96 mounted on TF96

KPR3-101L

TF96

—TF96 thermal overload relays40.0 to 96.0 A

Page 15: HTC ABB Low Voltage Products - hightech.com.au

HTC STOCK

LOW VO LTAG E PR O D U C TS 13

CR-M

CR-P/M…

CR-P/M 22

CR-P/M 92 CR-P/M 62VCR-P/M 92V

—Ordering details – CR-M range with LED

Rated control supply voltage

Outputs Contact ratings

Factory code Order code

12 V DC

2 c/o (SPDT) 250 V, 12 A

1SVR405611R4100 CRM012DC2L

24 V DC 1SVR405611R1100 CRM024DC2L

24 V AC 1SVR405611R0100 CRM024AC2L

110 V AC 1SVR405611R7100 CRM110AC2L

230 V AC 1SVR405611R3100 CRM230AC2L

24 V DC

3 c/o (SPDT) 250 V, 10 A

1SVR405612R1100 CRM024DC3L

24 V AC 1SVR405612R0100 CRM024AC3L

110 V AC 1SVR405612R7100 CRM110AC3L

230 V AC 1SVR405612R3100 CRM230AC3L

12 V DC

4 c/o (SPDT) 250 V, 6 A

1SVR405613R4100 CRM012DC4L

24 V DC 1SVR405613R1100 CRM024DC4L

48 V DC 1SVR405613R6100 CRM048DC4L

110 V DC 1SVR405613R8100 CRM110DC4L

125 V DC 1SVR405613R8300 CRM125DC4L

24 V AC 1SVR405613R0100 CRM024AC4L

110 V AC 1SVR405613R7100 CRM110AC4L

230 V AC 1SVR405613R3100 CRM230AC4L

— Ordering details – CR-M functional modules

Rated control supply voltage

Description Version Factory code Order code

6 - 220 V DC Diode - Reverse polarity protection/free wheeling diode

A1+, A2- 1SVR405651R0000 CRPM22

6 - 24 V DC Diode and LED - Reverse polarity protection/freewheeling diode

red, A1+, A2- 1SVR405652R0000 CRPM42

green, A1+, A2- 1SVR405652R1000 CRPM42V

24 - 60 V DC red, A1+, A2- 1SVR405652R4000 CRPM42B

green, A1+, A2- 1SVR405652R4100 CRPM42BV

110 V DC red, A1+, A2- 1SVR405652R9000 CRPM42C

green, A1+, A2- 1SVR405652R9100 CRPM42CV

6-24 V AC/DC Diode, LED and reverse polarity protection

green, for DC A1+, A2- 1SVR405654R1000 CRPM62V

110 V DC 110 - 230 V AC

red for DC A1+, A2- 1SVR405654R0100 CRPM92

green, for DC A1+, A2- 1SVR405654R1100 CRPM92V

For full selection and technical details, please refer to the Electronic relays and controls catalogue – 2CDC110004C0210.

— Ordering details – accessories

Version Connection terminal Factory code Order code

Logical socket for 2 c/o screw 1SVR405651R1100 CRM2LS

Logical socket for 3 c/o 1SVR405651R2100 CRM3LS

Logical socket for 2/4 c/o 1SVR405651R3100 CRM4LS

Logical socket for 2 c/o spring 1SVR405651R1200 CRM2LC

Logical socket for 2/4 c/o 1SVR405651R3200 CRM4LC

Standard socket for 2 c/o screw 1SVR405651R1000 CRM2SS

Standard socket for 3 c/o 1SVR405651R2000 CRM3SS

Standard socket for 2/4 c/o 1SVR405651R3000 CRM4SS

Plastic holder 1SVR405659R1000 CRMH

Metal holder 1SVR405659R1100 CRMH1

jumper bar for sockets with screw connection 1SVR405658R6000 CRMJ

CR-M4SS

CRMJ

CR-P/M 22 CR-P/M 42,

CR-P/M 42V,

CR-P/M 42BV,

CR-P/M 42CV

CR-P/M 92,

CR-P/M 62V,

CR-P/M 92V

CR-P/M 42CR-P/M 42BV

CR-P/M 42VCR-P/M 42CVCR-P/M 22 CR-P/M 42,

CR-P/M 42V,

CR-P/M 42BV,

CR-P/M 42CV

CR-P/M 92,

CR-P/M 62V,

CR-P/M 92V

CR-P/M 22 CR-P/M 42,

CR-P/M 42V,

CR-P/M 42BV,

CR-P/M 42CV

CR-P/M 92,

CR-P/M 62V,

CR-P/M 92V

Connecting diagrams

—Pluggable interface relaysOrdering details

Page 16: HTC ABB Low Voltage Products - hightech.com.au

HTC STOCK

14 HTC A B B O FFER I N G

CR-P relay

CR-PLSX

CR-PSS

—Pluggable interface relays and optocouplersCR-P range

DescriptionThe CR-P range offers the highest current switching in an IP67 rated relay housing. This range comprises of pluggable interface relays and optocouplers offered in 10 different con-trol supply voltages. Additionally, gold plated contacts are available for applications where sensitive signals are to be switched. The CR-P range also includes complete versions con-sisting of a relay, socket, holder, marker and function module.

—Ordering details – CR-M range with LED

Rated control supply voltage

Outputs Contact ratings

Factory code Order code

12 V DC

1 c/o(SPDT) 250 V, 16 A

1SVR405600R4000 CR-P012DC1

24 V DC 1SVR405600R1000 CR-P024DC1

48 V DC 1SVR405600R6000 CR-P048DC1

110 V DC 1SVR405600R8000 CR-P110DC1

24 V AC 1SVR405600R0000 CR-P024AC1

48 V AC 1SVR405600R5000 CR-P048AC1

110 V AC 1SVR405600R7000 CR-P110AC1

120 V AC 1SVR405600R2000 CR-P120AC1

230 V AC 1SVR405600R3000 CR-P230AC1

12 V DC

2 c/o(SPDT)

250 V, 8 A

1SVR405601R4000 CR-P012DC2

24 V DC 1SVR405601R1000 CR-P024DC2

48 V DC 1SVR405601R6000 CR-P048DC2

110 V DC 1SVR405601R8000 CR-P110DC2

12 V AC 1SVR405601R0200 CR-P012AC2

24 V AC 1SVR405601R0000 CR-P024AC2

48 V AC 1SVR405601R5000 CR-P048AC2

110 V AC 1SVR405601R7000 CR-P110AC2

120 V AC 1SVR405601R2000 CR-P120AC2

230 V AC 1SVR405601R3000 CR-P230AC2

Sockets*Standard and logical sockets for CR-P interface relays are suitable for snap-on mountingonto a DIN rail. Optional function modules for the CR-P range are plugged into both stan-dard and logical sockets.

—Ordering details – Sockets*

Version Connection terminal Factory code Order code

Logical socket with protective separation

screw 1SVR405650R0000 CR-PLS

Logical socket screw 1SVR405650R0100 CR-PLSX

spring 1SVR405650R0200 CR-PLC

Standard socket screw 1SVR405650R1000 CR-PSS

*All CR-P socket packages include a set of markers.

Standard socketsPosition of connection terminals: coil connection (A1-A2) on lower side of the socket, contact connections (n/o and n/c contacts) on the lower and upper side of the socket.

Logical socketsPosition of connection terminals: coil connection (A1-A2) on lower side of the socket, all contact connections (common contacts, n/o and n/c contacts) on the upper side of the socket.

Page 17: HTC ABB Low Voltage Products - hightech.com.au

HTC STOCK

LOW VO LTAG E PR O D U C TS 15

CT-D range CT-E range CT-S range

Timing function multifunctional single-functional multifunctional single-functional multifunctional single-functional

A ON-delay CT-MFD CT-ERD CT-MFE, CT-MKE CT-ERE, CT-EKE CT-MVS, CT-MFS, CT-MBS, CT-WBS

CT-ERS

B OFF-delay CT-MFD CT-AHD CT-MFE CT-AHE, CT-ARE, CT-AKE

CT-MVS, CT-MFS, CT-MBS

CT-APS, CT-AHS, CT-ARS

AB ON- and OFF-delay CT-MVS, CT-MXS, CT-MFS, CT-MBS

CA Impulse-ON CT-MFD CT-VWD CT-MFE, CT-MKE CT-VWE CT-MVS, CT-MFS, CT-MBS, CT-WBS

CB Impulse-OFF CT-MFD CT-AWE CT-MVS, CT-MFS, CT-MBS

CE Impulse-ON and OFF

CT-MXS

DA Flasher starting with ON

CT-MFD CT-EBD CT-MFE, CT-MKE CT-MFS, CT-MBS, CT-WBS

DB Flasher staring with OFF

CT-MFD CT-MFE, CT-MKE CT-EBE CT-MFS, CT-MBS, CT-WBS

DE Flasher starting with ON or OFF

CT-MVS

ED Pulse generator starting with ON or OFF

CT-TGD CT-MXS

H Pulse former CT-MFD CT-MFE CT-MVS, CT-MFS, CT-MBS

F Star-delta change-over

CT-SDD, CT-SAD CT-SDS

FC Star-delta change-over with impulse

CT-SDE CT-MVS.2x, CT-MFS, CT-MBS

FA Star-delta change-over twice ON-delayed

CT-YDE

A+ AC BC G further functions (depending on device)

CT-MVS, CT-MXS, CT-MFS, CT-MBS, CT-WBS

Technical data (extract)

Time ranges 7 (0.05 s – 100 h)CT-SDD, CT-SAD: 4 (0.05 s – 10 min)

Multifunction devices: 8 (0.05 s – 100 h) Single-function devices: 5 single ranges (0.05 – 1 s, 0.1 – 10 s, 0.3 – 30 s, 3 – 300 s, 0.3 – 300 min)

10 (0.05 s – 300 h) CT-ARS, CT-SDS: 7 (0.05 s – 10 min)

Control supply voltage Wide and multi ranges Wide ranges Single and dual ranges

Wide, multi and single ranges

Type and number of contacts 1 or 2 c/o contacts CT-SDD, CT-SAD: 2 n/o contacts

1 c/ o contact CT-SDE: 1 n/o contact and 1 n/c contact CT-MKE, CT-EKE, CT-AKE: 1 thyristor

1 or 2 c/o contacts CT-MVS.21, CT-MFS, CT-MBS: 2nd c/o contact selectable as inst. contact CT-SDS: 2 n/o contacts

Control inputs voltage-related triggering, polarized, capable of switching a parallel load

voltage-related triggering, polarized CT-MFE, CT-AHE, CT-AWE: with auxiliary voltage

voltage-related triggering, non-polarized, capable of switching a parallel load CT-MFS, CT-MBS, CT-AHS: volt-free triggering

—Timers, monitoring relays and power suppliesElectronic timers

Page 18: HTC ABB Low Voltage Products - hightech.com.au

HTC STOCK

16 HTC A B B O FFER I N G

CT-MFD.12

CT-ERD.22

DescriptionThe CT-D range in MDRC design with a width of only 17.5 mm fits into all domestic installation and distribution panels. The CT-D range represents a link between industry and the installation types. For maximum flexibility in operation, 10 single-function as well as 2 multifunction devices with 7 timing functions are available. The devices offer 4 or 7 time ranges from 0.05 seconds up to 100 hours. Their wide input range allows the use in applica-tions worldwide.

— Ordering details

Timing function Rated control supply voltage

Time ranges Control input

Output Factory code Order code

Multifunctional1) 24 – 240 V AC 7 (0.05 s – 100 h) ■ 1 c/o 1SVR500020R0000 CT-MFD.12

24 – 48 V DC

Multifunctional1) 12 – 240 V AC/DC 7 (0.05 s – 100 h) ■ 2 c/o 1SVR500020R1100 CT-MFD.21

ON-delay 24 – 240 V AC 7 (0.05 s – 100 h) – 1 c/o 1SVR500100R0000 CT-ERD.12

24 – 48 V DC – 2 c/o 1SVR500100R0100 CT-ERD.22

OFF-delay ■ 1 c/o 1SVR500110R0000 CT-AHD.12

■ 2 c/o 1SVR500110R0100 CT-AHD.22

Star-delta change-over 2)

4 (0.05 s – 10 min) – 2 c/o 1SVR500211R0100 CT-SDD.22

■ Control input with voltage-related triggering – no triggering

1) Functions: ON-delay, OFF-delay with auxiliary voltage, Impulse-ON, Impulse-OFF with auxiliary voltage, Flasher starting with ON, Flasher starting with OFF, Pulse former

2) Transition time 50 ms fixed

For full selection and technical details, please refer to the Electronic relays and controls catalogue – 2CDC110004C0210.

— Terminology

used expression alternative expression(s)

1 c/o contact SPDT

2 c/o contacts DPDT

voltage-related wet / non-floating

volt-free dry / floating

■Control input with voltage-related triggering – no triggering

—Timers, monitoring relays and power suppliesCT-D range

Page 19: HTC ABB Low Voltage Products - hightech.com.au

HTC STOCK

LOW VO LTAG E PR O D U C TS 17

—Single-functionalOnly reliable and continuous monitoring of a three-phase network guarantees the trou-ble-free and economic operation of machines and installations.

Rated control supply voltage = measuring voltage

Monitoring function Neutral monitoring

Factory code Order code

3 x 380 – 440 V AC, 1)

220 – 240 V CPhase failure detection (Single- and three-phase)

■ 1SVR550881R9400 CM-PBE.N

3 x 380 – 440 V AC 1SVR550882R9500 CM-PBE

3 x 208 – 440 V AC 2) Phase sequence monitoring and phase failure detection (Three-phase)

1SVR550824R9100 CM-PFE

3 x 200 – 500 V AC Phase sequence monitoring and phase failure detection (Three-phase)

1SVR730824R9300 CM-PFS.S

3 x 300 – 500 V AC Over- and undervoltage with adjustable threshold values (Three-phase)

1SVR730794R3300 CM-PVS.41S

1) The version with neutral monitoring is also suitable for monitoring single-phase mains. For this, all three external conductors (L1,L2,L3) have to be jumpered and connected as one single conductor.

2) For applications where a reverse fed voltage >60% is expected, we recommend to use our three-phase monitoring relays for unbalance CM-PAS.xx

CM-PBE

— Multifunctional

Rated control supply voltage = measuring voltage

DIP switch

Monitoring function Neutral monitoring

Factory code Order code

180 – 280 V AC ABkl

Multifunctional (Three-phase phase failure detection, Phase sequence monitoring, overvoltage, undervoltage, Phase unbalance)

■ 1SVR730885R3300 CM-MPS.21S

3 x 300 – 500 V AC 1SVR730884R3300 CM-MPS.41S

For full selection and technical details, please refer to the Electronic relays and controls catalogue – 2CDC110004C0210.

CM-MPS.21S

—Timers, monitoring relays and power suppliesThree-phase monitoring relays

— Terminology

used expression alternative expression(s)

■ Control input with voltage-related triggering

A ON-delayed

B OFF-delayed

k Phase sequence monitoring activated

l Phase sequence monitoring deactivated

S screw connection

P push-in / easy connec

Page 20: HTC ABB Low Voltage Products - hightech.com.au

HTC STOCK

18 HTC A B B O FFER I N G

CP1-10R-10

— Flush pushbutton with black plastic bezel as standard

Description Factory code Order codeMomentary2 NO 1SFA619100R102 ■ ■ CP1-10 ■ ■-202 NC 1SFA619100R105 ■ ■ CP1-10 ■ ■-021 NO +1 NC 1SFA619100R107 ■ ■ CP1-10 ■ ■-11Maintained2 NO 1SFA619101R102 ■ ■ CP2-10 ■ ■-202 NC 1SFA619101R105 ■ ■ CP2-10 ■ ■-021 NO +1 NC 1SFA619101R107 ■ ■ CP2-10 ■ ■-11

— Extended pushbutton with black plastic bezel as standard

Momentary2 NO 1SFA619102R102 ■ ■ CP3-10 ■ ■-202 NC 1SFA619102R105 ■ ■ CP3-10 ■ ■-021 NO +1 NC 1SFA619102R107 ■ ■ CP3-10 ■ ■-11

Maintained2 NO 1SFA619103R102 ■ ■ CP4-10 ■ ■-202 NC 1SFA619103R105 ■ ■ CP4-10 ■ ■-021 NO +1 NC 1SFA619103R107 ■ ■ CP4-10 ■ ■-11 — Flush pushbutton with black plastic bezel as standard

Momentary, white button marked with I (black)1 NO 1SFA619110R1015 CP11-10W-10

Momentary, white button with II (black)1 NO 1SFA619120R1015 CP12-10W -10

—Extended pushbutton with black plastic bezel as standard

Momentary, black button with O (white)1 NC 1SFA619132R1046 CP33-10B-01

— Bezel options

To order complete with a Chrome metal bezel – replace ‘1’ with ‘3’ in factory and order codes

1SFA61910XR30XX CP(X)-30X-XX

Description Factory code Order code

ll Red 1 NO + 1 NC 1SFA619126R1071 CPM3-10R-11

ll Green 1 NO + 1 NC 1SFA619126R1072 CPM3-10G-11ll Yellow 1 NO + 1 NC 1SFA619126R1073 CPM3-10Y-11ll Blue 1 NO + 1 NC 1SFA619126R1074 CPM3-10L-11ll Black 1 NO + 1 NC 1SFA619126R1076 CPM3-10B-11

Note: All mushroom pushbuttons are momentary. For maintained functions see machine stops or emergency stops

—Mushroom pushbuttons

CPM3-10R-11

CP1-30W-10

CP1-10U-10 CP1-30L-10

CP3-10Y-10 CP3-30G-10

CPM3-10L-11

CP11-10W-10

Colours ll Red ll Green ll Yellow ll Blue White ll Black ll Grey

Replace ■■ in Order code with R G Y L W B U

Replace ■■ in Factory code with 1 2 3 4 5 6 7

Bezel

—PushbuttonsFlush and extended

Page 21: HTC ABB Low Voltage Products - hightech.com.au

HTC STOCK

LOW VO LTAG E PR O D U C TS 19

Description Factory code Order code

ll Red 1 NO + 1 NC 1SFA619126R1071 CPM3-10R-11

ll Green 1 NO + 1 NC 1SFA619126R1072 CPM3-10G-11ll Yellow 1 NO + 1 NC 1SFA619126R1073 CPM3-10Y-11ll Blue 1 NO + 1 NC 1SFA619126R1074 CPM3-10L-11ll Black 1 NO + 1 NC 1SFA619126R1076 CPM3-10B-11

Note: All mushroom pushbuttons are momentary. For maintained functions see machine stops or emergency stops

— Pilot lights with integrated LED

Description Factory code Order code

Rated voltage 6.3 V DC 1) 1SFA619403R506 ■ ■ CL2-506 ■■

Rated voltage 12 V DC 1) 1SFA619403R501 ■ ■ CL2-501 ■■

Rated voltage 24 V AC/DC 1SFA619403R502 ■ ■ CL2-502 ■■

Rated voltage 48 – 60 V AC/DC 1SFA619403R507 ■ ■ CL2-507 ■■

Rated voltage 110 – 130 V AC 1SFA619403R513 ■ ■ CL2-513 ■■

Rated voltage 110 – 130 V DC 1) 1SFA619403R515 ■ ■ CL2-515 ■■

Rated voltage 220 V DC 1) 1SFA619403R520 ■ ■ CL2-520 ■■

Rated voltage 230 V AC 1SFA619402R523 ■ ■ CL2-523 ■■

Rated voltage 230 V AC with 60 V anti-inductive voltage 1SFA619403R623 ■ ■ CL2-623 ■■

Rated voltage 380 – 415 V AC 1SFA619403R542 ■ ■ CL2-542 ■■

Note: 1) Care should be taken for DC supply where + and - must be correctly connected. This is marked X1 (+) and X2 (-) on the product.

For information on rated current, wavelength and luminance – please refer to the technical catalogue – 1SFC151007C0201_RevB.

CL2-501L

Colours ll Red ll Green ll Yellow ll Blue Clear

Replace ■■ in Order code with R G Y L C

Replace ■■ in Factory code with 1 2 3 4 8

CL2-501R

—Pilot lights with integrated LED

Page 22: HTC ABB Low Voltage Products - hightech.com.au

HTC STOCK

20 HTC A B B O FFER I N G

• The SR2 enclosures range is a complete offer of monobloc enclosures for constructing small and medium sized automation, switching and control switchboards for industrial applications.

• IP65 rated according to AS/NZS 60529• 1.5 mm steel• Welded steel construction• Top and bottom gland plates• 2 mm galvanised steel mounting plate included

—SR2 metal enclosures IP65 – (indoor use only)

Height (mm) Width (mm) Depth (mm) Order code

SR2 enclosure 300 200 150 SRN3215K

300 150 SRN3315K

400 300 150 SRN4315K

300 200 SRN4320K

400 200 SRN4420K

500 400 200 SRN5420K

400 250 SRN5425K

600 400 200 SRN6420K

400 250 SRN6425K

600 250 SRN6625K

700 500 250 SRN7525K

800 600 300 SRN8630K

1000 600 300 SRN10630K

800 300 SRN10830K

1200 800 300 SRN12830K

—Accessories for SR2 metal enclosures IP65

Description Order code

Document pocket AA5600

Wall mounting brackets (Packet of 4 pcs) AA1206

Double tongue lock and key (spare part AA8001

Flush key lock with Yale type key AA8002

120°

AA8001X AA8002

AA5600

AA8011

AA8010

ZA....

GZ....

600800

1000

600250

80010001200

600300

W= 600mm

400500600

400200

500600

400 250

W=400mm

80010001200

800

300

W=800mm

Stackable boxes

AA1206

100

—Insulating enclosures and enclosures for automationIP65 SR2 sheet steel enclosures

Page 23: HTC ABB Low Voltage Products - hightech.com.au
Page 24: HTC ABB Low Voltage Products - hightech.com.au

HTC Head Office8 Stuart StreetPadstowNSW 2211

Phone: (02) 9771 4088www.hightech.com.au

—For more information contact: