HUAWEI TECHNOLOGIES CO., LTD.

Huawei Data Center NetHos Cabinet

For nearly 20 years, based on a deep understanding of cabinets, Huawei

launched NetHos Cabinets, providing a necessary foundation for

physical data center, and a suitable environment for the equipment, with

features of efficient cooling,perfect cabling management, flexible, simple

installation, compatibility, high reliability, high security and so on, which

are widely used in various types of data centers.

New NetHos Cabinets

Safe & Reliable Cabinetscomply with IEC 60297-2 standard. The distance between

the front and the rear mounting bars is adjustable,

providing a reasonable installation layout of various types

of system equipment.

Stable Structure DesignStatic load is no less than 1200kg, to ensure stability of

cabinets.

Leading heat dissipation

Super mesh door, ventilation rate is no less than 70 %, to

ensure the smooth flow of hot and cold air.

Good compatibilityStandardized design, compatible with 19-inch rack

equipment from different mainstream manufacturers.

simply Expansion Using a dedicated Cabinets connections,which support with

side panels and without side panels mounted side by side.

Professional distribution solutionsProfessional cabinet-level power system, providing various

types of power distribution solutions.

Perfect cable managementTrough at the top of the innovation, supporting top and

bottom outlet, facilitate field wiring.

1

Safe and reliable structural design, to meet a variety of IT applications

Using steel design, to meet a variety of high-density server •

deployments, provide reliable load.

Micro- environmental management,providing equipment with a •

comfortable operating environment with temperature control design.

Unified architecture platform to facilitate installation and maintenance

unified Server and cabling cabinets, distribution cabinets, air •

condition structure architecture, engineering interface for easy

installation and maintenance.

Without Tools design, without too much space installation •

requirements, easy deployment and installation.

Compatible with other mainstream manufacturers standard •

equipment, high-density server rack deployment.

Rich and optional cabinet accessories, to ensure cabinet convenient to use

Professional cabinet-level power system to provide various types of •

power distribution solutions.

Cable and hardware installation accessories, used on demand to •

facilitate the management and operation.

A variety of wind components to ensure smooth flow of hot and •

cold air.

Cabinet - level access control to ensure high securitySupport electronic door locks (induction credit card), while •

supporting the mechanical emergency unlocking.

Support centralized monitoring and off-line run independently, to •

realize intelligent monitoring.

New NetHos Cabinets

2

Technical Specification

Item Technical parameters

model FR42612 FR47612 FR42611 FR42812

dimension (W*D*H) 600*1200*2000 600*1200*2200 600*1100*2000 800*1200*2000

installation space

per cabinet42U 47U 42U 42U

Roller Y N Y Y

Air Front and rear air duct structure, door ventilation rate is 70%.

door structure Front single door and rear double doors

surface Surface powder thickness should be no less than 60 μm, meeting the requirements of Class A environment.

material Made of high-intensity class A carbon cold rolled steel sheet and zinc-coated steel sheet with thickness of 1mm~2mm

Protection Level IP20

Environmental standards Meet the ROHS standards

Front and rear door

opening angle120º

Note: can be customized according to the specific needs of the customer.

3

Cabinet PDU

From the performance: Basic PDU&monitoring PDU

type model VoltageElectric current

(A)

Capacity(KVA)

ConfigurationMounting direction

Basic PDU16-1PH-9/0-B220V

Single-phase16 3.5

9 C13 socket, without

open space1U

Basic PDU16-1PH-7-B220V

Single-phase16 3.5

7 international socket,

7 * 6A fuse protection1U

Basic PDU16-3PH-24/6-B380V

Three-phase16 11

3×(8 C13+2 C19),

without open space0U

Basic PDU16-1PH-5-B220V

Single-phase16 3.5

5 C13, 5*10A fuse

protection1U

Basic PDU30-3PH-18/3-B208V

Three-phase30 9

3×(6 C13+1 C19),

3*16A/2P open space0U

Basic PDU32-1PH-20/4-B220V

Single-phase32 7.3

2×(10 C13+2 C19),

2*16A/1Popen space0U

Basic PDU16-3PH-24/6-B380V

Three-phase16 11

3×(8 C13+2 C19),

without open space0U

Basic PDU63-1PH-16/9-B220V

Single-phase63 12.6

2×(4 C13+2 C19)

+2×(3 C13+3 C19),

4*16A/1P open space

0U

4

Cabinet PDU

From the installation: full height PDU & half height PDU & in-cabinet PDU

type model VoltageElectric current

(A)

Capacity(KVA)

ConfigurationMounting direction

Basic PDU32-1PH-9/4-B220V

Single-phase32 7.3

2×(5个C13+2个C19),

2*16A/1Popen spacehalf height

type model VoltageElectric current

(A)

Capacity(KVA)

ConfigurationMounting direction

monitoring PDU32-1PH-20/4-M220V

Single-phase32 7.3

2×(10 C13+2 C19),

2*16A/1Popen space0U

monitoring PDU16-3PH-24/6-M 380V

Three-phase16 11

3×(8 C13+2 C19),

without open space0U

monitoring PDU32-3PH-6/12-M380V

Three-phase32 22

6×(1 C13+2 C19),

6*16A/1P Magnetic

open space

0U

5

Front door

Cabinet Rack

NO.1 2m / 2.2m Mesh doorApplies to forward wind, after the wind air scenes, to meet cabinet with high ventilation rate.

NO.2 2m / 2.2m Access control doorAccess control doors have electric locks with the access control function.

TypeDimensions

(W*D*H/mm)Weight

(kg)Color

2m Mesh door 594*22*1927 8.2 black

2.2m Mesh door 594*22*2177 8.6 black

TypeDimensions

(W*D*H/mm)Weight

(kg)Color

2m Access control door 594*22*1927 8.5 black

2.2m Access control door 594*22*2177 9.1 black

6

Front door

Side Panel

Cabinet Rack

Side panels are installed inside the cabinet to seal cabinet sides and prevent dust. Side panels can be configured based on

requirements.

NO.3 2.2m Glass doorGlass doors have high sealing performance and can meet requirements of underfloor air supply scenarios.

TypeDimensions

(W*D*H/mm)Weight

(kg)Color

2.2m Glass door 594*22*2177 20 black

TypeDimensions(W*H/mm)

Weight(kg)

Color

2m side panel 1110*800 7.5 black

2.2m side panel 1110*920 8.4 black

7

Bottom Plate

Cabinet Rack

There are two types of bottom plates: Front air supply bottom plate and Underfloor air supply bottom plate.

NO.1 Front air supply bottom plate It applies to front air supply scenarios. It ensures the sealing between the mounting bars in the front and the foreside of the cabinet for

air flow isolation.

Dimensions(W*D*H/mm)

Applicable cabinet Model(W*D*H)

Weight(kg)

567*235* 9600*1200*2000

600*1200*22001.22

NO.2 Underfloor air supply bottom plateIt uses a removable structure and applies to common precision air supply, and full enclosure scenarios.

Dimensions(W*D*H/mm)

Applicable cabinet Model(W*D*H)

Weight(kg)

600*1100*30600*1200*2000

600*1200*22008.4

NO.3 Intelligent precision air supply bottom plate Intelligent precision air supply bottom plate is mainly used for under floor air scene, used with air deflector, air damper.

Dimensions(W*D*H/mm)

Applicable cabinet Model(W*D*H)

Weight(kg)

600*1100*30 600*1200*2000

600*1200*22007.0

8

Tray

Hardware Installation

Cabinet tray is mainly used to load equipment, divided into fixed tray and adjustable tray.

NO.1 fixed trayA fixed try is used to facilitate device installation and placement. It supports standard devices, can bear a weight of 100 kg.

Dimensions(W*D*H/mm)

Weight(kg)

Load capacity(kg)

483*622*62 3.37 100

Rail

L - shaped guide rail for both sides of the cabinet, a standard design, can withstand the fixed guide mobile device or equipment.

Dimensions(W*D*H/mm)

Weight(kg)

Load capacity(kg)

Depth range(mm)

42*622*37 0.72 50 645~720

NO.2 adjustable trayAdjustable tray used to load equipment, according to the square hole depth adjustment.

Dimensions(W*D*H/mm)

Weight(kg)

Load capacity(kg)

Depth range(mm)

481*870*43.6 5.6 100 570~870

9

PDU Mounting Plate

Hardware Installation

The PDU mounting plate support PDU installation. The cabinet supports PDU screw installation and without-tool mounting.

PDU mounting plate including full-height and half-height PDU mounting plate.

NO.1 full-height PDU mounting plateIt is used for the installation of full height PDUs. Full height PDUs are clamped onto the mounting plates or secured to the plates by

using screws, making the installation simple and easy. Both 2 m and 2.2 m full height PDU mounting plates use a segmental structure.

NO.2 half-height PDU mounting plateIt is used for the installation of half height PDUs. Half height PDUs are clamped onto the mounting plates or secured to the plates by

using screws. 2.0 m mounting plates use a unitary design and support the installation of vertical cabling modules. 2.2 m mounting

plates use a three-segment design.

Type Dimensions (W*H/mm) Structure Model Weight (kg)

Full height PDU

mounting plate

Upper segment / Lower

segment: 125*200

Upper-lower two-

segment0.537

Upper segment / Lower

segment: 125*50

Upper-lower two-

segment1.09

Type Dimensions (W*H/mm) Structure Model Weight (kg)

2.0 m half height PDU

mounting plate125*1900 Unitary 2.89

Type Dimensions (W*H/mm) Structure Model Weight (kg)

2.2 m half height PDU

mounting plate

Upper segment: 125*350

Middle segment: 125*450

Lower segment: 125*300

Upper-middle-lower

three-segment1.5

10

Cabling Unit

Cable Management

Cabinet horizontal cabling management, and a decorative tool.

Cable Ring

A cable fastener is installed on a vertical column in the cabinet for vertical-cable management.

Dimensions (W*D*H/mm) Weight (kg)

48 *188.6 *50 0.163

Dimensions (W*D*H/mm)

Weight (kg) Trace amount Space Occupied

482.6 *91 *43.6 0.56 48 *6 square thread 1U

11

Depth-directed Cable Manager

Cabling Tray

Cable Management

A depth-directed cable manager is used for depth-directed cabling. Its drawer design supports various mounting bar distances.

A cabling tray is used for forward and backward cabling. It uses unique mounting ears to facilitate device installation.

Dimensions (W*H) Weight (kg) Depth range (mm)

50*36 0.537 442.5~742.5

Dimensions (W*D*H) Weight (kg) Space Occupied

482.6*250*43.6 1.89 1U

12

Dummy Panel

"L" Airtight Bar

Airflow Management

If certain space in the cabinet is not occupied, install filler panels in that position to prevent wind and beautify the cabinet.

“L” Airtight Bar is used for sealing.

NO.1 1U dummy panel1 U dummy panel occupied by 1U space.

NO.1 2U dummy panel2 U dummy panel occupied by 2U space.

Type Dimensions (W*D*H) Weight(kg)

1U dummy Panel 482.6*25*44 0.12

Type Dimensions (W*D*H) Weight (kg)

2U dummy Panel 482.6*25*88.5 0.216

Type Dimensions (W*D*H) Weight (kg)

“L”Airtight Bar 598.5 *10*72.5 0.656

13

Air Deflector

Airflow Management

Air deflectors apply to underfloor air supply scenarios. Cabinet air deflectors are classified into the following two types

based on air supply modes: Common precision air supply air deflector & Intelligent precision air supply air deflector.

NO.1 Common precision air supply air deflectorIt applies to common precision air supply scenarios and used with an underfloor air supply bottom plate.

Dimensions (W*D*H) Weight (kg) Space Occupied

482.6*332*138 2.4 3U

NO.2 Intelligent precision air supply air deflectorIt applies to intelligent precision air supply scenarios and used with an air valve and an underfloor air supply bottom plate.

Dimensions (W*D*H) Weight (kg) Space Occupied

442*709.5*130.6 4.26 3U

NO.3 Air damperAir damper used with intelligent precision air supply air deflector, realize intelligent precision air supply.

Dimensions (W*D*H/mm) Input Voltage (V DC) Operating Temperature (ºC)

442*650*86 24 5~40

14

Other Unit

Cabinet Bracket

Cabinets supporting bracket for the booster and the supporting cabinet.

width (mm) depth (mm)Applicable anti-static floor

height (mm)

600 1200 600

Copper Ground Bar

A copper ground bar is used for the grounding of devices inside the cabinet.

There are M6 and M8 terminals on a copper bar. M6 terminal ports are used for device grounding, and M8 for leading out

ground cables. Insulators can be used to isolate the copper bar from the cabinet to ensure high grounding reliability. Users

can configure insulators as required.

Dimensions (W*D*H) Installation Mode Number of Terminals

490*3*30It can be horizontally installed on

mounting bars.19*M6+2*M8

Door Status Sensor

A door status sensor can be installed on the front door or rear door of the cabinet. It generates an alarm when detecting

abnormal cabinet door status. Door status sensors can be configured based on customers' requirements.

Rated current (mA)

Rated power(W)

Securing mode

Switch form color

500 10 Screw Normally open

White acrylonitrile

butadiene styrene (ABS)

engineering plastic

15

Other Unit

Lighting System Fittings

Lighting System Fitting achieves cabinet lighting. Light system fittings include a daylight lamp and a touch switch.

NO.1 Daylight LampLED lamps are used for lighting in the cabinet. Each server is configured with two LED lamps on the top at the two ends of the cabinet.

NO.2 Touch SwitchA touch switch automatically turns on the daylight lamp when detecting that cabinet doors are open and turns it off when the doors

are closed. It uses advanced NC contacts with high sensitivity.

Installation mode Securing mode Power (W) Service life (h)

Roof-mounted or wall-

mounted

With buckles (delivered

with the lamp)2~6 ≥10000

Rated working voltage (V)

Rated working current (A)

Installation modeService life

(times)

220 10

Mechanical screw

installation, such as surface

mounting technology

(SMT) and add-in)

100000

16

Applications

CMCC Southern Base IDC

Venezuela CANTV Data Center

Shanghai Telecom Data Center

17

Copyright © Huawei Technologies Co., Ltd. 2013. All rights reserved.

General Disclaimer

The information in this document may contain predictive statements including, without limitation, statements regarding the future financial and operating results, future product portfolio, new technology, etc. There are a number of factors that could cause actual results and developments to differ materially from those expressed or implied in the predictive statements. Therefore, such information is provided for reference purpose only and constitutes neither an offer nor an acceptance. Huawei may change the information at any time without notice.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Industrial Base

Bantian Longgang

Shenzhen 518129, P.R. China

Tel: +86-755-28780808

Version No.: M3-035748-20130530-C-2.0

www.huawei.com

About Network Energy of Huawei

Based on the deep understanding about telecommunication in a long term of 20 years, and the construction

and maintenance experience of more than 1.5 million global telecommunication sites, Huawei network energy

product line adheres the ‘4S’ concepts of ‘Simple, Scalable, Smart, Saving’, and commits to providing customers

the world's leading network energy solutions.

The network energy product line has two main businesses of site energy and data center energy. We are making

stable, green energy and infrastructure for customers in ICT field, building a solid foundation for excellence

networks, protecting customers’ long term investment on energy and infrastructure.

About Huawei

Huawei is a leading global ICT solutions provider. Through our dedication to customer-centric innovation and

strong partnerships, we have established end-to-end capabilities and strengths across the carrier networks,

enterprise, consumer, and cloud computing fields. We are committed to creating maximum value for telecom

carriers, enterprises and consumers by providing competitive ICT solutions and services. Our products and

solutions have been deployed in over 140 countries, serving more than one third of the world's population.