huc6800+_c_ed-a_175-000293-00
TRANSCRIPT
HUC6800+ and HUC6800+C Broadcast Upconverters
Installation and Operation Manual
Edition A175-000293-00
Edition AJuly 2006
HUC6800+ andHUC6800+CBroadcast Upconverters
Installation and Operation Manual
Trademarks and CopyrightsCCS, CCS CoPilot, CCS Navigator, CCS Pilot, Command Control System, CineTone, CinePhase, CineSound, DigiBus, DigiPeek, Digital Glue, DigiWorks, DTV Glue, EventWORKS, EZ HD, Genesis, HDTV Glue, Image Q, Icon, IconLogo, IconMaster, IconMaster Nav, IconSet, Icon Station, Inca, Inca Station, InfoCaster, Inscriber, Inscriber CG—FX, Integrator, LeFont, Leitch, LogoMotion, MediaFile, MIX BOX, NEO, the NEO design, NEOSCOPE, NewsFlash, Nexio, Opus, Panacea, PanelMAPPER, Platinum, Portal, PROM-Slide, RouterMAPPER, RouterWORKS, Signal Quality Manager, SpyderWeb, SuiteView, TitleMotion, UNIFRAME, Velocity, VelocityHD, VideoCarte, Videotek, and X75 are trademarks of the Harris Corporation, which may be registered in the United States, Canada, and/or other countries. All other trademarks are the property of their respective owners.Copyright 2006, Harris Corporation. All rights reserved. This publication supersedes all previous releases. Printed in Canada.
Warranty InformationThe Limited Warranty Policy provides a complete description of your warranty coverage, limitations, and exclusions, as well as procedures for obtaining warranty service. To view the complete warranty, visit www.broadcast.harris.com/leitch.
Contents
PrefaceManual Information .............................................................................. vii
Purpose ........................................................................................... viiAudience ........................................................................................ viiRevision History ............................................................................ viiWriting Conventions ..................................................................... viiiObtaining Documents ................................................................... viii
Unpacking/Shipping Information .......................................................... ixUnpacking a Product ....................................................................... ixProduct Servicing ............................................................................ ixReturning a Product ........................................................................ ix
Restriction on Hazardous Substances (RoHS) Compliance ....................xWaste from Electrical and Electronic Equipment (WEEE) Compliance xiSafety .................................................................................................... xii
Safety Terms and Symbols in this Manual .................................... xii
Chapter 1: IntroductionOverview ..................................................................................................1Product Description ..................................................................................2
Main Features ...................................................................................2Applications ......................................................................................3
Module Description ..................................................................................4Front Module ....................................................................................4Back Connectors ...............................................................................6Signal Flow .......................................................................................6
Chapter 2: InstallationOverview ..................................................................................................9
HUC6800+ Installation and Operation Manual iii
Contents
Maximum 6800+ Frame Power Ratings ............................................... 10Unpacking the Module .......................................................................... 11
Preparing the Product for Installation ............................................ 11Checking the Packing List ............................................................. 11
Setting Jumpers ..................................................................................... 12Installing HUC6800+ and HUC6800+C Modules ............................... 14Upgrading Module Firmware ................................................................ 15
Upgrading the Firmware ................................................................ 15Correcting a Failed Upgrading Procedure ..................................... 18
Chapter 3: OperationOverview ............................................................................................... 23Operating Notes ..................................................................................... 24Audio and Video Synchronization and Delay ....................................... 24
Audio Sync and Delay ................................................................... 26Video Frame Sync and Delay ........................................................ 26
Input and Output Standards ................................................................... 27Aspect Ratio Conversion ....................................................................... 28
Selecting a Standard Aspect Ratio ................................................. 28Setting a Custom Aspect Ratio ...................................................... 28Saving, Selecting, and Recalling Saved Aspect Ratios ................. 30Overscan Mode .............................................................................. 31Bypass Mode .................................................................................. 31
Changing Parameter Settings ................................................................ 33Recalling Default Parameter Settings ............................................ 34On Screen Display (OSD) Monitoring ........................................... 34Reading Software and Hardware Versions .................................... 34Cross-Functional Parameter Changes ............................................ 35
Control Parameters ................................................................................ 36LEDs and Alarms .................................................................................. 48
Monitoring LEDs ........................................................................... 48Module Status LEDs ...................................................................... 50Alarms ............................................................................................ 50
Chapter 4: SpecificationsOverview ............................................................................................... 51Inputs ..................................................................................................... 52
SD/HD-SDI Video ......................................................................... 52Genlock .......................................................................................... 52
iv HUC6800+ Installation and Operation Manual
Contents
Outputs ...................................................................................................53SD/HD-SDI Reclocked Video ........................................................53Upconverted HD-SDI Video ..........................................................54
Miscellaneous .........................................................................................55Audio Delay (Data Out) ..................................................................55Power Consumption ........................................................................55Operating Temperature ...................................................................55
Appendix A: Communication and Control Troubleshooting Tips
Overview ................................................................................................57General Troubleshooting Steps ..............................................................58Software Communication and Control Issues ........................................59
+ Pilot Lite Fails to Communicate with Installed Modules ...........59+ Pilot Lite Does Not Find All Modules in Frame ........................60+ Pilot Lite or CCS Software Application Not Responding ..........61+ Pilot Lite Cannot Control a Module Showing in the Control Window ...................................................................61+ Pilot Lite Status Bar Reports ‘Not Ready’ ..................................61CCS Software Application or Remote Control Panel Does Not Communicate with Module ............................................................62Alarm Query Fails When a Device Reboots ...................................62
Hardware Communication and Control Issues ......................................63Frames Fail to Communicate with the PC after a Power Failure ...63Module Does Not Seem to Work ....................................................63
Contacting Customer Service .................................................................63
IndexKeywords ...............................................................................................65
HUC6800+ Installation and Operation Manual v
Contents
vi HUC6800+ Installation and Operation Manual
Preface
Manual Information
PurposeThis manual details the features, installation, operation, maintenance, and specifications for the HUC6800+ Broadcast Upconverter.
AudienceThis manual is written for engineers, technicians, and operators responsible for installation, setup, maintenance, and/or operation of the HUC6800+ Broadcast Upconverter.
Revision HistoryTable P-1. Revision History of Manual
Edition Date CommentsA July 2006 Initial release
HUC6800+ Installation and Operation Manual vii
Preface
Writing ConventionsTo enhance your understanding, the authors of this manual have adhered to the following text conventions:
Obtaining DocumentsProduct support documents can be viewed or downloaded from our Web site at www.broadcast.harris.com/leitch (go to Support> Documentation). Alternatively, contact your customer service representative to request a document.
Table P-2. Writing Conventions
Term or Convention Description
Bold Indicates dialog boxes, property sheets, fields, buttons, check boxes, list boxes, combo boxes, menus, submenus, windows, lists, and selection names
Italics Indicates E-mail addresses, the names of books or publications, and the first instances of new terms and specialized words that need emphasis
CAPS Indicates a specific key on the keyboard, such as ENTER, TAB, CTRL, ALT, or DELETE
Code Indicates variables or command-line entries, such as a DOS entry or something you type into a field
> Indicates the direction of navigation through a hierarchy of menus and windows
hyperlink Indicates a jump to another location within the electronic document or elsewhere
Internet address Indicates a jump to a Web site or URL
NoteIndicates important information that helps to avoid and troubleshoot problems
viii HUC6800+ Installation and Operation Manual
Preface
Unpacking/Shipping InformationUnpacking a Product
This product was carefully inspected, tested, and calibrated before shipment to ensure years of stable and trouble-free service. 1. Check equipment for any visible damage that may have occurred
during transit. 2. Confirm that you have received all items listed on the packing list. 3. Contact your dealer if any item on the packing list is missing.4. Contact the carrier if any item is damaged.5. Remove all packaging material from the product and its associated
components before you install the unit.Keep at least one set of original packaging, in the event that you need to return a product for servicing.
Product ServicingExcept for firmware upgrades, HUC6800+ modules are not designed for field servicing. All hardware upgrades, modifications, or repairs require you to return the modules to the Customer Service center.
Returning a ProductIn the unlikely event that your product fails to operate properly, please contact Customer Service to obtain a Return Authorization (RA) number, then send the unit back for servicing. Keep at least one set of original packaging in the event that a product needs to be returned for service. If the original package is not available, you can supply your own packaging as long as it meets the following criteria:• The packaging must be able to withstand the product’s weight.• The product must be held rigid within the packaging.• There must be at least 2 in. (5 cm) of space between the product and
the container.• The corners of the product must be protected.Ship products back to us for servicing prepaid and, if possible, in the original packaging material. If the product is still within the warranty period, we will return the product prepaid after servicing.
HUC6800+ Installation and Operation Manual ix
Preface
Restriction on Hazardous Substances (RoHS) Compliance
Directive 2002/95/EC—commonly known as the European Union (EU) Restriction on Hazardous Substances (RoHS)—sets limits on the use of certain substances found in electrical and electronic equipment. The intent of this legislation is to reduce the amount of hazardous chemicals that may leach out of landfill sites or otherwise contaminate the environment during end-of-life recycling. The Directive takes effect on July 1, 2006, and it refers to the following hazardous substances: • Lead (Pb)• Mercury (Hg)• Cadmium (Cd)• Hexavalent Chromium (Cr-V1)• Polybrominated Biphenyls (PBB)• Polybrominated Diphenyl Ethers (PBDE)According to this EU Directive, all products sold in the European Union will be fully RoHS-compliant and “lead-free.” (See our Web site, www.broadcast.harris.com/leitch, for more information on dates and deadlines for compliance.) Spare parts supplied for the repair and upgrade of equipment sold before July 1, 2006 are exempt from the legislation. Equipment that complies with the EU directive will be marked with a RoHS-compliant emblem, as shown in Figure P-1.
Figure P-1. RoHS Compliance Emblem
x HUC6800+ Installation and Operation Manual
Preface
Waste from Electrical and Electronic Equipment (WEEE) Compliance
The European Union (EU) Directive 2002/96/EC on Waste from Electrical and Electronic Equipment (WEEE) deals with the collection, treatment, recovery, and recycling of electrical and electronic waste products. The objective of the WEEE Directive is to assign the responsibility for the disposal of associated hazardous waste to either the producers or users of these products. Effective August 13, 2005, producers or users will be required to recycle electrical and electronic equipment at end of its useful life, and may not dispose of the equipment in landfills or by using other unapproved methods. (Some EU member states may have different deadlines.)In accordance with this EU Directive, companies selling electric or electronic devices in the EU will affix labels indicating that such products must be properly recycled. (See our Web site, www.broadcast.harris.com/leitch, for more information on dates and deadlines for compliance.) Contact your local sales representative for information on returning these products for recycling. Equipment that complies with the EU directive will be marked with a WEEE-compliant emblem, as shown in Figure P-2.
Figure P-2. WEEE Compliance Emblem
HUC6800+ Installation and Operation Manual xi
Preface
SafetyCarefully review all safety precautions to avoid injury and prevent damage to this product or any products connected to it. If this product is rack-mountable, it should be mounted in an appropriate rack using the rack-mounting positions and rear support guides provided. It is recommended that each frame be connected to a separate electrical circuit for protection against circuit overloading. If this product relies on forced air cooling, it is recommended that all obstructions to the air flow be removed prior to mounting the frame in the rack. If this product has a provision for external earth grounding, it is recommended that the frame be grounded to earth via the protective earth ground on the rear panel.IMPORTANT! Only qualified personnel should perform service procedures.
Safety Terms and Symbols in this ManualWARNINGStatements identifying conditions or practices that may result in personal injury or loss of life. High voltage is present.
CAUTIONStatements identifying conditions or practices that can result in damage to the equipment or other property.
xii HUC6800+ Installation and Operation Manual
Chapter 1
Introduction
OverviewThe HUC6800+ and HUC6800+C modules are HDTV upconverters with aspect ratio conversion (ARC) and SD/HD digital video distribution amplification capabilities. The “C” version module supports closed captioning data.This chapter introduces the HUC6800+ and HUC6800+C, and includes the following topics:• “Product Description” on page 2• “Module Description” on page 4
NoteThe HUC6800+ and HUC6800+C modules can only be installed and operated in an FR6802+XF frame.
HUC6800+ Installation and Operation Manual 1
Chapter 1: Introduction
Product DescriptionThe HUC6800+ and HUC6800+C upconverter modules provide conversion from SD-SDI to a user-selectable HD-SDI standard. These modules provide two active reclocked SD/HD-SDI outputs, four synchronized HD-SDI outputs, and a genlock reference video input. They also include ARC capabilities, and can accept embedded audio and ANC data. The HUC6800+C version supports closed captioning data processing.The modules’ SDI input has error monitoring capabilities in the SD mode (EDH), and they support external or midplane genlock sources.Both modules can be controlled locally (via card edge) or controlled and monitored remotely with control software applications such as CCS +Pilot Lite,™ Pilot™, and Navigator™, or other CCS-compliant remote control products.
Main FeaturesImportant HUC6800+ and HUC6800+C features include the following:• Auto-detectable/user-selectable input/output standards and formats• Error monitoring on SDI input• One selectable SD/HD-SDI input with embedded audio data• Two dedicated HD-SDI outputs carrying the program signal with
embedded audio; two additional HD-SDI outputs carrying either the same program signal or the key signal (user-selectable)
• Two SD/HD-SDI outputs for carrying equalized and reclocked program signals
• Variable aspect ratio conversion (ARC) with five user presets• Color-space conversion from SD to HD• Audio sync and delay, including incremental audio delay• Video frame delay of up to 7 frames• Support for closed caption data processing (HUC6800+C only)• User-configurable picture-resizing aspect ratio conversion (H/V
size, H/V position)• User-selectable color for internally-generated ARC background
2 HUC6800+ Installation and Operation Manual
Chapter 1: Introduction
• Adjustable vertical blanking size in fields 1 and 2; transfer of closed captioning information between formats
• 24-bit audio processing• Embedded audio processing (demultiplexing from SDI, delay/sync,
sample rate conversion, and remultiplexing into SDI)• Support for two groups (eight channels) of embedded audio• Support for compressed audio data and linear PCM audio data in
the same audio group• Built-in HD test generator containing cross-hatch pattern, color
bars signal, luma sweep, and SAG (safe area generator) key• HD-SDI luma (soft edge rectangle) key output of non-picture area
ApplicationsThe HUC6800+ and HUC6800+C modules are suitable for the following applications:• Upconversion of HD content for monitoring applications, such as
driving large screen displays with upconverted HD content• Upconversion of HD content for on-air applications where utility
quality HD upconversion is acceptable
HUC6800+ Installation and Operation Manual 3
Chapter 1: Introduction
Module Description
Front ModuleFigure 1-1 shows the position of the LEDs and module controls on the front of the HUC6800+ and HUC6800+C modules.
Figure 1-1. Typical 6800+ Module
Table 1-1 on page 5 briefly describes generic 6800+ LEDs, switches, and jumpers.
Module status LEDs
Mode select rotary switch
Navigation toggle switch
Monitoring LEDs
Remote/local control jumper
Extractor handle
Control LEDs
4 HUC6800+ Installation and Operation Manual
Chapter 1: Introduction
Table 1-1. Generic 6800+ Module Features
Feature DescriptionModule status LEDs
Various color and lighting combinations of these LEDs indicate the module state. See “LEDs and Alarms” on page 48 for more information.
Mode select rotary switch
This switch selects between various control and feedback parameters.
Navigation toggle switch
This switch navigates up and down through the available control parameters:• Down: Moves down through the parameters• Up: Moves up through the parameters
Control LEDs Various lighting combinations of these Control LEDs (sometimes referred to as “Bank Select LEDs”) indicate the currently selected bank. See “Bank Select LEDs” on page 33 for more information.
Monitoring LEDs
Each 6800+ module has a number of LEDs assigned to indicate varying states/functions. See “Monitoring LEDs” on page 48 for a description of these LEDs.
Local/remote control jumper
• Local: Locks out external control panels and allows card-edge control only; limits the functionality of remote software applications to monitoring
• Remote: Allows remote or local (card-edge) configuration, operation, and monitoring of the HUC6800+ and HUC6800+C
See page 12 for more information on jumpers.
HUC6800+ Installation and Operation Manual 5
Chapter 1: Introduction
Back ConnectorsFigure 1-2 shows the double-slot back connector used by the HUC6800+ and HUC6800+C modules. The back connectors and the modules must be installed in an FR6802+XF frame (6800/7000 series frames do not provide backward-compatibility).
Figure 1-2. HUC6800+ and HUC6800+C Back Connectors
Signal FlowFigure 1-3 on page 7 illustrates the signal flow of the HUC6800+ and HUC6800+C modules.
1 2
1 2
RCLKSD/HDOUT
HDPROG/MONOUT
1
2
SD/HD IN
HD PROGOUT
REF IN
DATA OUT
6 HUC6800+ Installation and Operation Manual
Chapter 1: Introduction
Figure 1-3. HUC6800+ and HUC6800+C Block Diagram
Gen
lock
(HD
onl
y)
Gen
lock
refe
renc
e
Fram
ere
fere
nce
CC
608
payl
oad
into
708
[SD
]
[SD
/HD
]
HD
is fo
r out
put i
npa
ss m
ode
Fram
esy
nc[S
D]
2 gr
oup
aud
io/A
NC
dem
ux[S
D]
Aud
io s
ync
+de
lay
SD/H
DSD
IH
D/S
D-S
DI
dese
rializ
er
HD
/SD
-SD
IEQ
2D vide
osc
alar
Aud
io/
AN
C/C
Cem
bedd
er[H
D]
Col
orsp
ace
conv
ersi
on60
1 to
709
Ret
icul
eke
yer
[HD
]
Key
sign
al[H
D]
Vide
o te
stge
nera
tor
[HD
]
On
scre
endi
spla
y[H
D]
HD
-SD
Ipr
ogra
mou
tput
HD
-SD
Im
onito
rou
tput
HD
-SD
Ise
rializ
er +
cabl
e dr
iver
HD
-SD
Ise
rializ
er +
cabl
e dr
iver
HD
-SD
Ise
rializ
er +
cabl
e dr
iver
SDI
recl
ocke
dou
tput
Driv
erIO
DLY
(aud
io)
HUC6800+ Installation and Operation Manual 7
Chapter 1: Introduction
8 HUC6800+ Installation and Operation Manual
Chapter 2
Installation
OverviewThis chapter describes the HUC6800+ and HUC6800+C installation process, including the following topics:• “Maximum 6800+ Frame Power Ratings” on page 10• “Unpacking the Module” on page 11• “Setting Jumpers” on page 12• “Installing HUC6800+ and HUC6800+C Modules” on page 14• “Upgrading Module Firmware” on page 15
See the FR6802+ Frame Installation and Operation Manual for information about installing and operating an FR6802+ frame and its components.
CautionBefore installing this product, read the 6800+ Series Safety Instructions and Standards Manual shipped with every FR6802+ Frame Installation and Operation Manual. This information is also available at www.broadcast.harris.com/leitch. The safety manual contains important information about the safe installation and operation of 6800+ series products.
HUC6800+ Installation and Operation Manual 9
Chapter 2: Installation
Maximum 6800+ Frame Power RatingsThe power consumption for the HUC6800+ and HUC6800+C modules is less than 10.5 W. Table 2-1 shows the maximum allowable power ratings for 6800+ frames. Note the given maximums before installing any 6800+ modules in your frame.HUC6800+ and HUC6800+C modules can be installed in FR6802+XF frames only.
Table 2-1. Maximum Power Settings for Frames with AC Power Supply
6800+ Frame Type
Max. Frame Power Dissipation
Number of Usable Slots
Max Power Dissipation for Two Slots
FR6802+XF(frame with fans)
120 W 10 12 W
Table 2-2. Maximum Power Settings for Frames with DC Power Supply
6800+ Frame Type
Max. Frame Power Dissipation
Number of Usable Slots
Max Power Dissipation for Two Slots
FR6802+XF(frame with fans)
105 W 10 10.5 W
10 HUC6800+ Installation and Operation Manual
Chapter 2: Installation
Unpacking the Module
Preparing the Product for InstallationBefore you install the HUC6800+ and HUC6800+C, perform the following:• Check the equipment for any visible damage that may have
occurred during transit.• Confirm receipt of all items on the packing list. See “Checking the
Packing List” below for more information.• Remove the anti-static shipping pouch, if present, and all other
packaging material.• Retain the original packaging materials for possible re-use.
See “Unpacking/Shipping Information” on page ix for information about returning a product for servicing.
Checking the Packing List
NoteContact your customer service representative if parts are missing or damaged.
Table 2-3. Available Product Packages
Ordered Product Content DescriptionHUC6800+ or HUC6800+C module
• One front module• One back connector• One HUC6800+ and HUC6800+C Broadcast
Upconverters Installation and Operation Manual
HUC6800+ Installation and Operation Manual 11
Chapter 2: Installation
Setting JumpersThe HUC6800+ and HUC6800+C modules have one standard jumper (REM/LOC) for remote or local control, and one jumper (J1) for Genlock termination. Figure 2-1 shows the location of the jumpers.
Figure 2-1. HUC6800+ and HUC6800+C Jumpers
REM/LOC (remote/local) jumper
Jumper J1genlock termination
12 HUC6800+ Installation and Operation Manual
Chapter 2: Installation
Local and Remote Jumper SettingsFollow this procedure to set the REM/LOC jumper for either remote or local control:1. Locate the REM/LOC control jumper on the module (beside the
mode select rotary switch). Figure 2-1 on page 12 shows the standard location of the REM/LOC jumper.
2. Place a jumper on pins 1 and 2 to set the module for Remote control, or pins 2 and 3 to set the module for Local control. See Figure 2-2.
Figure 2-2. REM/LOC Settings for Remote and Local Control
See Table 1-1 on page 5 for more information on local/remote control jumper functionality.
Genlock Termination Jumper SettingsFollow this procedure to set the Genlock Termination jumper J1:1. Locate jumper J1 on the module, near the back of the module.
(Figure 2-1 on page 12 shows the location of the jumper.)2. Place a jumper on pins 1 and 2 to set the module for No
Termination, or pins 2 and 3 to set 75Ω Onboard Termination (see Figure 2-3).
Figure 2-3. Genlock Termination Settings
NoteYou must configure modules for local or remote operation prior to power-up. To change the configuration, first remove power from the module, reset the jumper, and then reapply power.
The white triangle near the jumper pins on the module indicates pin 1.
1 2 3 1 2 3
Remote control Local control
1 2 3 1 2 3
No Termination 75Ω Termination
HUC6800+ Installation and Operation Manual 13
Chapter 2: Installation
Installing HUC6800+ and HUC6800+C ModulesThe HUC6800+ HUC6800+C modules have double-width back connectors that must be installed in an FR6802+XF frame.These modules require no specialized installation or removal procedures. However, if you are installing both front and rear modules, ensure that the back module is installed first before plugging in the front module. Likewise, ensure that the front module is unplugged from the frame before removing the rear module. See the FR6802+ Frames Installation and Operation Manual for information about installing and operating an FR6802+ frame and its components.
14 HUC6800+ Installation and Operation Manual
Chapter 2: Installation
Upgrading Module FirmwareFirmware upgrading is a routine procedure that you must perform to install newer versions of software on 6800+ modules. Pilot, Co-Pilot, or Navigator software version 3.1.1 or later is required for this procedure. The frame must contain or be connected to another frame that contains an ICE6800+ module. You can use either the Discovery or the drag-and-drop method. When performing the upgrading procedure, check the appropriate readme file to confirm which files are needed. Use care to ensure that you upload the correct files to the intended module.In the unlikely event that the upgrade fails, the module may not respond to controls and will appear to be non-functional. In that event, follow the procedures described in “Correcting a Failed Upgrading Procedure” on page 18.
Upgrading the FirmwareThere are two methods for upgrading the firmware:• “Upgrading the Firmware Using the Discovery Method” on
page 15• “Upgrading Firmware Using the Drag-and-Drop Method” on
page 17
Upgrading the Firmware Using the Discovery MethodFollow these steps to upgrade the firmware using the discovery method:1. Download the most recent appropriate upgrade package from our
Web site or from your CD-ROM.2. If the affected module has not been discovered, perform the
Discovery operation, as described in your CCS software application manual or online help. (If you cannot discover the device, see “Upgrading Firmware Using the Drag-and-Drop Method” on page 17.)
3. From the Tools menu, select Software Upgrade.
HUC6800+ Installation and Operation Manual 15
Chapter 2: Installation
The Software Upgrade window opens or is brought to the foreground.
Figure 2-4. Software Upgrade Tool’s New Transfer Tab
4. On the New Transfer tab, click Add.The Device Selection dialog opens.
5. Select one or more devices, and then click OK to close the Add Device dialog box.You can only add one unit from each IP address. All items in a frame have the same IP address. The selected devices appear in the table on the New Transfer tab of the Software Upgrade window. This table lists devices that are to receive the same upgrade package. For each device in this table, you can highlight its position in the Tree View by clicking Find Device. You can check the software revision numbers, etc., by clicking Version Info, and create an automatic backup by clicking the Device Options... button. (Place a check beside Software Backup and enter a file name or click Browse to choose a new file location.)
Device Options provide access to options for entering Telnet and FTP user name and password, and for creating automatic backups.
Package Info includes a list of the components contained in the ZIP
16 HUC6800+ Installation and Operation Manual
Chapter 2: Installation
6. Press Browse... to select the software upgrade package (ZIP file). A standard Windows File Selection dialog opens.
7. Choose the upgrade ZIP file on a local or network drive. The selected file’s path name is displayed in the edit box to the left of the Browse… button.The extraction process on the ZIP file is handled as part of the upgrade process. You do not need to extract the files yourself.
8. Press Submit Transfer... A dialog box opens, requesting confirmation that you want to proceed with the request. If you have multiple devices selected, multiple transfer tasks are submitted—one per device.The transfer now progresses. You may close the Software Upgrade window, continue with other tasks, or switch to the Progress tab to view the status of the transfers.
9. Click on the Log tab and look at the Progress column to ensure that all files have correctly updated. The module is automatically rebooted following an upgrade procedure.
Upgrading Firmware Using the Drag-and-Drop MethodFollow these steps to upgrade the firmware using the drag-and-drop method:1. Download the appropriate most recent upgrade package from our
Web site or from your CD-ROM, and then unzip the upgrade package.
2. If the affected module has not been discovered by your CCS software application, enter the Build mode, and then drag or copy and paste the module’s device icon from the catalog folder into the Network or Discovery folder.
3. Right-click the device icon, and then select Properties.
NoteClosing the Software Upgrade window does not effect any of the transfer processes that may be running in the background.
NoteIf you try to log off or exit the CCS software while a transfer is underway, a notification window will alert you that processes are still active and will ask if you want to terminate these processes.
HUC6800+ Installation and Operation Manual 17
Chapter 2: Installation
4. On the Device tab of the Navigation Properties box, enter the IP address of the frame that holds the module. (See Figure 2-5.)
Figure 2-5. Navigation Properties Box
5. In the third field, enter the slot number of the module, and then close the window.
You can now continue upgrading your device’s firmware, starting with step 3 on “Upgrading the Firmware” on page 15.
Correcting a Failed Upgrading ProcedureFirmware upgrades may fail in the event of network interruptions, power failures, or if files were sent to the wrong 6800+ module.These problems can be corrected by re-installing the firmware while in Boot Loader mode, as described in the following pages. Before you perform this procedure, check the appropriate readme file to confirm which files are needed. Use care to ensure that you upload the correct files to the intended module.
CautionIf you make changes in the last field (located above and to the right of the Set Default button), you may lose your connection to the module. If this happens, you will need to rediscover the module.
Do not make changes in this field
Enter frame IP number here
18 HUC6800+ Installation and Operation Manual
Chapter 2: Installation
Follow these steps to upgrade a 6800+ module in Boot Loader mode:1. Remove the affected module from the 6800+ frame.
Figure 2-6. Buttons on a Typical Card Edge
2. Set the Hex switch to F. 3. While pressing the Navigation toggle switch down, reinsert the
module into the frame.4. Download the most recent appropriate upgrade package from our
Web site or from your CD-ROM, and then unzip the upgrade package.
5. If the affected module has not been discovered by your CCS software application, enter Build mode, and then drag or copy and paste the module’s device icon from the catalog folder into the Network or Discovery folder.
6. Right-click the device icon and then select Properties.
Hex switch (Mode select rotary switch)
Navigation toggle switch
NoteTo successfully upgrade the firmware, you must follow these steps in the exact sequence described.
HUC6800+ Installation and Operation Manual 19
Chapter 2: Installation
7. On the Device tab of the Navigation Properties box, enter the IP address of the frame that holds the module. (See Figure 2-7.)
Figure 2-7. Navigation Properties Box
8. In the third field, enter: 1.0.[slotnumber](Where, for example, 1.0.5 would refer to the module in slot 5 of the frame.)
9. Close the window.10. Double-click the device icon.
The Configuration... box opens. On the File Transfer tab, the /frame/slot (where x is the slot number) directory appears in the Select the device directory to transfer to: field.
11. Click Add. 12. In the Add Upgrade Files box, browse, select the module’s
upgrade package and then click OK.13. Choose the file you wish to upgrade and then click OK.14. Click Perform Transfer, and then click Yes.
This may take several minutes.
CautionIf you make changes in the last field (located above and to the right of the Set Default button), you may lose your connection to the module. If this happens, you will need to rediscover the module.
Do not make changes in this field
Enter frame IP address here
NoteYou must delete unwanted files in the Add upgrade files for transfer to device: field before transferring the files. Otherwise, the upgrading procedure will fail.
20 HUC6800+ Installation and Operation Manual
Chapter 2: Installation
15. Wait for the message File transfer to device succeeded in the status bar.
16. Click Reboot Device, and then click Yes.After the module has rebooted, a message box advises you to wait until the device has rebooted.
17. Wait 30 seconds.Your upgrade procedure is complete.
NoteSome 6800+ modules will reboot automatically. In these cases, the Reboot button will be grayed out.
HUC6800+ Installation and Operation Manual 21
Chapter 2: Installation
22 HUC6800+ Installation and Operation Manual
Chapter 3
Operation
OverviewThis chapter describes how to operate the HUC6800+ and HUC6800+C using card-edge controls only. See the following documents for information on how to operate this product remotely:• +Pilot Lite User Manual for serial interface• CCS Pilot, CoPilot, Navigator, or LCP-3901-1U/RCP-CCS-1U
manuals for Ethernet interfaceThe following topics are discussed in this chapter:• “Operating Notes” on page 24• “Audio and Video Synchronization and Delay” on page 24• “Aspect Ratio Conversion” on page 28• “Changing Parameter Settings” on page 33• “On Screen Display (OSD) Monitoring” on page 34• “Control Parameters” on page 36• “LEDs and Alarms” on page 48
HUC6800+ Installation and Operation Manual 23
Chapter 3: Operation
Operating NotesWhen setting the control parameters on the HUC6800+ and HUC6800+C, observe the following:• If you make changes to certain parameters, other related parameters
may also be affected. See “Cross-Functional Parameter Changes” on page 35 for more information.
• When you change a parameter, the effect is immediate. However, the module requires up to 20 seconds to save the latest change. After 20 seconds, the new settings are saved and will be restored if the module loses power and must be restarted.
• For proper operation, the output HD standard frame rate should match or double the reference standard frame rate.
• The manufacturer recommends that you terminate any unused coaxial output connectors with a 75Ω terminator.
Audio and Video Synchronization and DelayDuring upconversion, delay is added to the SDI input signal in the main video processing path. The amount of delay to the primary signal is dependent upon the type of processing applied to it. Table 3-1 on page 25 contains breakdowns of the major video propagation delays through the video synchronizer and converter blocks.The SD-SDI input signal is frame-synchronized to the genlock reference. Using the Input Frame Delay parameter, you can compensate for other external processes. The Input Frame Delay parameter provides a delay range between 0 to 6 frames in one-frame increments.The video frame synchronizer (frame sync) on the SDI input provides synchronization using the following sources:• SDI program input timing (Delay Mode)• Reference timing (Sync Mode)In Sync Mode, the frame synchronizer automatically detects and locks to the genlock reference signal for video timing alignment. The frame synchronizer either drops or repeats video frames to achieve synchronization.
24 HUC6800+ Installation and Operation Manual
Chapter 3: Operation
Table 3-1. Video Propagation Delays for Upconversion
Mode Input Output FrameSync
SD Frame Delay Upconvert HD User
Output Delay
Sync SD-525 1080i_59.94 0~1 I-frame 0~6 I-frames 1 I-frame 0~1 I-frame
SD-525 720p_59.94 0~1 I-frame 0~6 I-frames 2 P-frame 0~1 P-frame
SD-625 1080i_50 0~1 I-frame 0~6 I-frames 1 I-frame 0~1 I-frame
SD-625 720p_50 0~1 I-frame 0~6 I-frames 2 P-frame 0~1 P-frame
Delay SD-525 1080i_59.94 N/A 0~6 I-frames 1 I-frame 0~1 I-frame
SD-525 720p_59.94 N/A 0~6 I-frames 2 P-frame 0~1 P-frame
SD-625 1080i_50 N/A 0~6 I-frames 1 I-frame 0~1 I-frame
SD-625 720p_50 N/A 0~6 I-frames 2 P-frame 0~1 P-frame
Bypass 1080i_59.94 1080i_59.94 N/A N/A Bypass: 0 N/A
720p_59.94 720p_59.94 N/A N/A Bypass: 0 N/A
1080i_50 1080i_50 N/A N/A Bypass: 0 N/A
720p_50 720p_50 N/A N/A Bypass: 0 N/A
HUC6800+ Installation and Operation Manual 25
Chapter 3: Operation
Audio Sync and DelayAudio is synchronized to video by applying the same frame sync delay and converter delay to the audio associated with that video path.By changing the Input Frame Delay control, you can adjust the frame sync delay and trigger the audio to resynchronize with the video. The audio synchronization will not occur immediately and will take roughly 10 seconds per frame of delay in order to prevent any audio “glitch.”You can add additional delay using the Audio Embedded Pair 1 Delay to Audio Embedded Pair 4 Delay parameters.The user delay is always applied in addition to the audio synchronization and will cause an audio glitch to occur when the user delay changes.
Video Frame Sync and DelayThe HUC6800+ and HUC6800+C modules provide upconversion from SD-SDI to user-selectable HD-SDI standards. During upconversion, there is a certain amount of delay added to the SD-SDI input signal in the main video processing path. The amount of delay to the signal is dependent on the type of processing applied to it.The SD-SDI input signal is frame-synchronized to the genlock reference. A user frame delay control is available to compensate for other external processes. The user delay interface provides a delay range between 0 to 6 frames in one-frame increments. This delay is expressed in SD input units of 525 (NTSC) and 625 (PAL) frames.
26 HUC6800+ Installation and Operation Manual
Chapter 3: Operation
Input and Output StandardsThe Output Video Standard parameter and the Input Video Standard parameters are related in their function. If Auto is selected in the Input Video Standard, the Output Video Standard will select either 1080i (interlaced) or 720p (progressive) and the frame rate will follow. If Auto is selected in the Input Video Standard, the module will accept the incoming format (525 or 625) and the frame rate will follow (that is, 1080i/720p at 59.94 or 50, respectively).If you require an output that always has the same frame rate (for example, 1080i/59.94 or 1080i/50), select either 525 or 625, respectively, as an input standard. In this configuration, if the input changes, the other standard will be treated as loss of video—for which you can designate Pass, Black, Freeze, or Test Pattern handling.An HD signal that is fed into the input when Auto is selected will place the module in Bypass mode if the frame rate in the input and output are the same. If the input HD signal has a different frame rate than the output, the loss-of-video circuit will be enabled; the signal cannot enter Bypass.
HUC6800+ Installation and Operation Manual 27
Chapter 3: Operation
Aspect Ratio ConversionThe HUC6800+ can output either a standard or custom aspect ratio.
Selecting a Standard Aspect RatioTo select a standard aspect ratio for the output image, scroll to ARC Preset Select in the control parameter list item and then select one of the aspect ratio settings from the list. The following standard aspect ratios are available:• 16:9 Anamorphic• 16:9 Cut• 14:9• 4:3• Pixel True (1:1 pixel to pixel mapping)See Figure 3-1 on page 29 for a graphic illustration of the standard aspect ratios.
Setting a Custom Aspect RatioYou can scale and pan the output image to any size and location by using the custom aspect ratio feature in the HUC6800+ and HUC6800+C modules. To select the custom aspect ratio feature, scroll to the ARC Preset Select parameter and then select Custom. Then scroll to the menu items ARC H Scale, ARC V Scale, ARC H Offset, and ARC V Offset to set the size and position accordingly. Descriptions of the controls are listed below; for minimum values, see Table 3-4 on page 35.• ARC H Scale–sets the horizontal size of the output image
anywhere between minimum and 200% of the output screen size. • ARC V Scale–sets the vertical size of the output image anywhere
between minimum and 200% of the output screen size.• ARC H Offset–places the horizontal center of the output image
anywhere between –50% and 50% of the output screen size. • ARC V Offset–places the vertical center of the output image
anywhere between –50% to 50% of the output screen size.
28 HUC6800+ Installation and Operation Manual
Chapter 3: Operation
Figure 3-1. Standard ARC Upconversion Settings
4:3 Display Input Signal
4:3Source
16:9 Display Anamorphic
4:3Source
4:3Source
16:9 Display 16:9 Cut
16:9 Display 4:3
4:3Source
4:3Source
16:9 Display 14:9
16:9 Display PixelTrue
4:3Source
4:3 Input 16:9 Display Output ARCOptions
HUC6800+ Installation and Operation Manual 29
Chapter 3: Operation
Saving, Selecting, and Recalling Saved Aspect RatiosYou can save, select, and recall up to five custom aspect ratios in the HUC6800+ and HUC6800+C modules.
Saving a Custom Aspect RatioTo save a custom aspect ratio, follow these steps:1. Make sure the ARC H Scale, ARC V Scale, ARC H Offset, and
ARC V Offset parameters have been set. 2. Scroll down to the menu item ARC Preset Save and then select one
of the five aspect ratio preset slots for storage.3. Wait approximately 2 seconds for the module to process the
command.
Selecting a Saved Custom Aspect RatioTo select one of the custom saved aspect ratios for the output image, follow these steps:1. Scroll to the ARC Preset Select parameter.2. Select one of the five saved aspect ratios: Preset1, Preset2,
Preset3, Preset4, or Preset5. 3. Wait approximately 2 seconds for the module to process the
command.
Recalling a Saved Custom Aspect RatioBy selecting the ARC Preset Recall parameter, you can also recall any built-in standard or custom saved aspect ratio settings without changing the output image. The ARC Preset Recall parameter will overwrite the following custom aspect ratio parameters: ARC H Scale, ARC V Scale, ARC H Offset, and ARC V Offset. If you perform an aspect ratio recall when ARC Preset Select is set to Custom, the output image aspect ratio will revert to the recalled aspect ratio.
30 HUC6800+ Installation and Operation Manual
Chapter 3: Operation
Overscan ModeThe overscan mode is similar to a zoom mode. When enabled, it discards a specified number of lines and columns of pixels around the borders of the input image active picture region before upconversion.The active picture region for 525 standard starts on line 21 and ends at line 262. Therefore, an overscan setting of one line implies that upconversion starts at line 22 and ends at line 261. In addition to the two discarded lines, the first and last pixel of each remaining line in the active picture region are discarded.The overscan mode prevents embedded data in the active picture region, such as closed captioning, from being upconverted.To enable the overscan mode, scroll to the ARC Overscan parameter and then select the number of rows and columns for cropping.
Bypass ModeWhen an HD-SDI signal is input to the HUC6800+ or HUC6800+C, the module detects that no upconversion processing on the input is required. Therefore, the module operates in Bypass mode, which means that the module’s input signal bypasses the upconverter and is output to the program and monitoring outputs unprocessed. However, if On-Screen Display (OSD) monitoring is enabled, the OSD will be present in HD Prog/Mon Output 1 and HD Prog/Mon Output 2. For information about the OSD monitoring feature, see “On Screen Display (OSD) Monitoring” on page 34.When the module is operating in Bypass mode, many parameters are disabled. See Table 3-2 for list a list of parameters that are disabled when the module is operating in Bypass mode.
Table 3-2. Parameters Disabled in Bypass Mode
Disabled ParametersLovOut DmxErrCtrl
TstPat AudEmbSrc
TstPatOn AudEmbPr1
CrcErrPollTime AudEmbPr2
CrcErrClr AudEmbPr3
HUC6800+ Installation and Operation Manual 31
Chapter 3: Operation
CcEmbed AudEmbPr4
ArcPreset AudMstrMute
ArcTransMode AudPr1Gain
ArcTransTime AudPr2Gain
ArcHScale AudPr3Gain
ArcVScale AudPr4Gain
ArcHOffset AudPr1Dly
ArcVOffset AudPr2Dly
ArcOverscan AudPr3Dly
ArcSave AudPr4Dly
ArcRecall AudPr12OutGrp
AudPr34OutGrp
Table 3-2. Parameters Disabled in Bypass Mode(Continued)
Disabled Parameters
32 HUC6800+ Installation and Operation Manual
Chapter 3: Operation
Changing Parameter SettingsFollow these steps to change the HUC6800+ and HUC6800+C parameter settings:1. Rotate the mode select rotary switch (hex switch) to “0.”2. Once the hex switch is set to “0,” toggle the navigation switch up or
down to select a bank. View the three control LEDs next to the navigation toggle switch to see which bank is currently selected.
3. Rotate the hex switch to the parameter number (1 to 9) or letter (A to F) of the option you want to set.
4. Toggle the navigation switch to select and set the value of the chosen parameter.
5. Rotate the hex switch to another parameter number/letter in the current bank, and then repeat step 4.orRotate the hex switch to “0” again to select a different bank, and then repeat steps 3 and 4.See Table 3-5 on page 36 to view the various banks, hex switch positions, and corresponding parameter options and values.
Table 3-3. Bank Select LEDs
Bank Number
Bank 0 LED(first top LED)
Bank 1 LED(second top LED)
Bank 2 LED (third top LED)
0 Off Off Off
1 On Off Off
2 Off On Off
3 On On Off
4 Off Off On
5 On Off On
NoteThe manufacturer recommends that you use the available 6800+ software control options (serial/local or Ethernet/remote) to aid in viewing, setting, and confirming parameter values.
HUC6800+ Installation and Operation Manual 33
Chapter 3: Operation
Recalling Default Parameter SettingsTable 3-5 on page 36 describes all of the parameter settings for the HUC6800+ and HUC6800+C, including the original factory defaults. To return this module to its default settings, you can either reset each parameter individually or do a global recall following this procedure:1. Rotate the hex switch to “0.”2. Toggle the navigation switch to the bank number “0.”
Use the control LEDs to verify which bank you have selected, or use an available 6800+ software control option (serial/local or Ethernet/remote) to confirm your bank selection.
3. Rotate the hex switch to the global recall parameter “F.”4. Toggle the navigation switch to Yes.
Use an available 6800+ software control option to aid in viewing, setting, and confirming the parameter value.
On Screen Display (OSD) MonitoringThe HUC6800+ and HUC6800+C modules have two dedicated HD-SDI outputs that carry the program signal. There are two additional user-configurable SDI outputs that carry either the same program signal or an overlaid on-screen display (OSD) monitoring signal. The OSD can be turned On or Off by setting the On Screen Display parameter to the desired option. When in the On position, the output can be used as a display monitor to view the current parameter selections and controls.
Reading Software and Hardware VersionsYou can see the current software and hardware versions of the HUC6800+ by checking the Hardware Version and Firmware Version read-only parameters located at the end of the parameter list (see page 47). These parameters appear in the OSD (see above), and on CCS-enabled control panels or CCS software applications—such as Pilot or Navigator.
34 HUC6800+ Installation and Operation Manual
Chapter 3: Operation
Cross-Functional Parameter ChangesWhen you configure certain parameters, changes are forced in other associated parameters. For example, when Horizontal Phase is controlled from the card edge, any wrap-around of the values will cause a corresponding increment or decrement of the Vertical Phase value.
Table 3-4. Cross-Functional Parameter Changes
Parameter Affected by HD-SDI Output Standard and Frame Rate
HD-SDI Output Video Standard/Frame Rate
Parameter Name 720p/50 Hz 720p/59.94 Hz 1080i/50 Hz 1080i/59.94 Hz
Vertical Phase 0 to 749 lines 0 to 749 lines 0 to 1124 lines 0 to 1124 lines
Horizontal Phase 0 to 1979 pixels 0 to 1649 pixels 0 to 2639 pixels 0 to 2199 pixels
Vertical Scale 40–200% 33.75–200% 53.34–200% 45–200%
Horizontal Scale 56.25–200% 56.25–200% 37.50–200% 37.50–200%
HUC6800+ Installation and Operation Manual 35
Chapter 3: Operation
Control ParametersThe following table lists all of the available parameters and options for the HUC6800+ and HUC6800+C. All parameters clip unless otherwise indicated.The On/Off combinations of the control LEDs on the card-edge indicate the active bank number. See “Changing Parameter Settings” on page 33 for more information.LegendBold option = Indicates that this is the default setting for the parameter[RO] = Indicates that parameters are read-only/feedback, and cannot be used to select controls* = Indicates that this parameter wraps when controlled from the card edge
NoteThe sequence of options listed in the Options column mirrors the sequence achieved when you move the Navigation Toggle switch up.
Table 3-5. Control Parameters
Bank, Rotary Switch
Parameter Name Function Options
X Bank Select Selects the active bank number 0 to 5
Bank 0
0, 1 Output Video Standard Selects the SDI output video signal standard (only the applicable options are displayed in the OSD)
• 720p59.94• 1080i59.94• 720p50• 1080i50
0, 2 On Screen Display Turns on/off the on-screen display • Off• On
0, 3 OSD Transparency Sets the on-screen display transparency level
0 to 15
0, 4 Input Video Standard Selects the SDI input video signal standard(Note: If you select a non-synchronous standard, the OSC will disappear; if this occurs, use the LEDs to find Factory Recall and then regain use of the OSD. This will take several seconds.)
• Auto• 525• 625
36 HUC6800+ Installation and Operation Manual
Chapter 3: Operation
0, 5 Loss of Video Output Selects an output option when loss of input occurs
• Pass• Black• Freeze• Test Pattern
0, 6 Test Pattern Selects a test pattern (Test Pattern Display parameter must first be set to On)
• Color Bar 75%• Cross Hatch• Freq Sweep• White• Black
0, 7 Test Pattern Display Turn on/off the test pattern display • Off• On
0, 8 Safe Area Turns on/off various safe area overlays • Off• Action On• Title On• Action & Title On
0, 9 Video Keying Turns on/off video keying for the SDI output
• Off• Key Image• Key Background
0, A Background Color Sets the background color • Black• Super Black• Red 50%• Green 50%• Blue 50%• Orange 50%• Grey 50%• Grey 40%• Grey 25%
Table 3-5. Control Parameters (Continued)
Bank, Rotary Switch
Parameter Name Function Options
HUC6800+ Installation and Operation Manual 37
Chapter 3: Operation
0, B Output H Phase Sets the horizontal phase for the output signal
• 0 to 1979 pixels(720p/50 Hz)
• 0 to 1649 pixels (720p/59.94 Hz)
• 0 to 2639 pixels (1080i/50 Hz)
• 0 to 2199 pixels (1080i/59.94Hz)
0, C Output V Phase Sets the vertical phase for the output signal • 0 to 749 (720p)• 0 to 1124 line (1080i)
0, D Genlock Source Selects the Genlock source(When the video input source is HD-SDI, this parameter defaults to Delay, because there is no external/frame reference for the HD signal as it bypasses the processor.)
• External Ref• Frame Ref• Free Run• Delay
0, E Reference Video Standard Selects the reference standard (The applicable 525 or 625 options are displayed in the OSD; if the standard is mismatched with the genlock source, the Reference LED will light.)
• Auto• NTSC/PAL-M• TLS 720p59.94• TLS 1080i59.94• PAL-B• TLS 720p50• TLS 1080i50
0, F Factory Recall Recalls the factory default settings • No• Yes
Bank 1
1, 1 EDH Error Poll Time Defines the polling interval for EDH error detection
1 to 14400 sec
1, 2 EDH Error Clear Clears the EDH error count (The Yes option remains visible after selection in CCS software applications only.)
• No• Yes
1, 3 Input Frame Delay Sets the amount of input frame delay 0 to 6 frames
Table 3-5. Control Parameters (Continued)
Bank, Rotary Switch
Parameter Name Function Options
38 HUC6800+ Installation and Operation Manual
Chapter 3: Operation
1, 4 ARC Preset Select Selects a preset ARC configuration • 16:9 Anamorphic• 16:9 Cut• 14:9• 4:3• Pixel True• Preset 1• Preset 2• Preset 3• Preset 4• Preset 5• Custom
1, 5 ARC Transition Mode Sets the ARC transition mode(Currently this parameter has only one option. More options will be added with future releases.)
Cut
1, 6 ARC Transition Time Sets the ARC transition duration(Currently the control for this parameter is disabled.)
0
1, 7 ARC H Scale Sets the ARC horizontal scale Minimum to 200.00% (100) (see Table 3-4 on page 35)
1, 8 ARC V Scale Sets the ARC vertical scale Minimum to 200.00% (100) (see Table 3-4 on page 35)
1, 9 ARC H Offset Sets the ARC horizontal offset -50.00% to 50.00% (0)
1, A ARC V Offset Sets the ARC vertical offset -50.00% to 50.00% (0)
1, B ARC Overscan Discards a specified number of rows and columns of pixels around the input image before upconversion
0, 2, 4, 6, 8, 10, 12, 14
Table 3-5. Control Parameters (Continued)
Bank, Rotary Switch
Parameter Name Function Options
HUC6800+ Installation and Operation Manual 39
Chapter 3: Operation
1, C ARC Preset Save Saves the current ARC configuration to a specific preset
• None• Preset 1• Preset 2• Preset 3• Preset 4• Preset 5
1, D ARC Preset Recall Recalls an ARC configuration • None• 16:9 Anamorphic• 16:9 Cut• 14:9• 4:3• Pixel True• Preset 1• Preset 2• Preset 3• Preset 4• Preset 5
1, E Not available
1, F Frame Sync Freeze Selects the freeze type for the frame synchronizer
• Off• Frame• Field 1• Field 2
Bank 2
2, 1 Demux Error Control Selects an action when an error sample is selected
• Mute• Repeat
Table 3-5. Control Parameters (Continued)
Bank, Rotary Switch
Parameter Name Function Options
40 HUC6800+ Installation and Operation Manual
Chapter 3: Operation
2, 2 Audio Demux Source Selects an audio source. (If Custom is selected, use the Audio Embedded Pair 1 Select, Audio Embedded Pair 2 Select, Audio Embedded Pair 3 Select, and Audio Embedded Pair 4 Select parameters to specify which audio pairs to demux.)
• Demux Grp 1 & 2• Demux Grp 3 & 4• Custom
2, 3 Audio Pair 1 Select Selects a source for audio channel pair 1 • Demux Grp 1 Pr 1• Demux Grp 1 Pr 2• Demux Grp 2 Pr 1• Demux Grp 2 Pr 2• Demux Grp 3 Pr 1• Demux Grp 3 Pr 2• Demux Grp 4 Pr 1• Demux Grp 4 Pr 2
2, 4 Audio Pair 2 Select Selects a source for audio channel pair 2 • Demux Grp 1 Pr 1• Demux Grp 1 Pr 2• Demux Grp 2 Pr 1• Demux Grp 2 Pr 2• Demux Grp 3 Pr 1• Demux Grp 3 Pr 2• Demux Grp 4 Pr 1• Demux Grp 4 Pr 2
2, 5 Audio Pair 3 Select Selects a source for audio channel pair 3 • Demux Grp 1 Pr 1• Demux Grp 1 Pr 2• Demux Grp 2 Pr 1• Demux Grp 2 Pr 2• Demux Grp 3 Pr 1• Demux Grp 3 Pr 2• Demux Grp 4 Pr 1• Demux Grp 4 Pr 2
Table 3-5. Control Parameters (Continued)
Bank, Rotary Switch
Parameter Name Function Options
HUC6800+ Installation and Operation Manual 41
Chapter 3: Operation
2, 6 Audio Pair 4 Select Selects a source for audio channel pair 4 • Demux Grp 1 Pr 1• Demux Grp 1 Pr 2• Demux Grp 2 Pr 1• Demux Grp 2 Pr 2• Demux Grp 3 Pr 1• Demux Grp 3 Pr 2• Demux Grp 4 Pr 1• Demux Grp 4 Pr 2
2, 7 Audio Master Mute Turns the master mute on/off • Off• On
2, 8 Audio Pair 1 Gain Sets the gain level for audio channel pair 1 -6.0 to 6.0 dB (0)
2, 9 Audio Pair 2 Gain Sets the gain level for audio channel pair 2 -6.0 to 6.0 dB (0)
2, A Audio Pair 3 Gain Sets the gain level for audio channel pair 3 -6.0 to 6.0 dB (0)
2, B Audio Pair 4 Gain Sets the gain level for audio channel pair 4 -6.0 to 6.0 dB (0)
2, C Audio Pair 1 Delay Sets the delay for audio channel pair 1 0 to 1200 msec
2, D Audio Pair 2 Delay Sets the delay for audio channel pair 2 0 to 1200 msec
2, E Audio Pair 3 Delay Sets the delay for audio channel pair 3 0 to 1200 msec
2, F Audio Pair 4 Delay Sets the delay for audio channel pair 4 0 to 1200 msec
Bank 3
3, 1 Audio Pair 1 & Pair 2 Output Group
Selects the output group number to embed channel pair 1 and 2
• Group 1• Group 2• Group 3• Group 4
3, 2 Audio Pair 3 & Pair 4 Output Group
Selects the output group number to embed channel pair 3 and 4
• Group 1• Group 2• Group 3• Group 4
Table 3-5. Control Parameters (Continued)
Bank, Rotary Switch
Parameter Name Function Options
42 HUC6800+ Installation and Operation Manual
Chapter 3: Operation
3, 3 Audio Master Bypass Sets the master bypass • Auto• On• Off
3, 4 Audio Pair 1 Bypass Sets the bypass for audio channel pair 1 • On• Off
3, 5 Audio Pair 2 Bypass Sets the bypass for audio channel pair 2 • On• Off
3, 6 Audio Pair 3 Bypass Sets the bypass for audio channel pair 3 • On• Off
3, 7 Audio Pair 4 Bypass Sets the bypass for audio channel pair 4 • On• Off
3,8 CC Embed (“-C” version only)
Turns on/off the closed caption embedding • On• Off
3,9 CC Embed Position(“-C” version only)
Sets the video line to embed closed captioning data
line 9 to 20 (1080i/59.94)line 9 to 25 (720p/59.94)
3,A to3, F
Not available
Bank 4
4, 1 Bypass Mode Feedback [RO]
Displays the status of the upconverter bypass mode
• Off• On
4, 2 Input Video Standard Detect [RO]
Displays the detected input video standard • Unknown• 525• 720p59.94• 1080i59.94• 625• 720p50• 1080i50
4, 3 Frame Sync Freeze Status [RO]
Confirms whether the output video is frozen
• Yes• No
Table 3-5. Control Parameters (Continued)
Bank, Rotary Switch
Parameter Name Function Options
HUC6800+ Installation and Operation Manual 43
Chapter 3: Operation
4, 4 CC Present [RO] Indicates the presence of closed captioning • No• Yes
4, 5 ARC Horizontal Scale Feedback [RO]
Displays the current ARC horizontal phase Minimum to 200.00% (see Table 3-4 on page 35)
4, 6 ARC Vertical Scale Feedback [RO]
Displays the current ARC vertical phase Minimum to 200.00% (see Table 3-4 on page 35)
4, 7 ARC Horizontal Offset Feedback [RO]
Displays the current ARC horizontal offset -50.00% to 50.00%
4, 8 ARC Vertical Offset Feedback [RO]
Displays the current ARC vertical offset -50.00% to 50.00%
4, 9 Audio Group Present [RO]
Indicates the present audio group • ====• 1===• =2==• ==3=• ===4• 12==• 1=3=• 1==4• =23=• =2=4• ==34• 123=• 12=4• 1=34• =234• 1234
Table 3-5. Control Parameters (Continued)
Bank, Rotary Switch
Parameter Name Function Options
44 HUC6800+ Installation and Operation Manual
Chapter 3: Operation
4, A Audio Channel Pair Feedback [RO]
Displays the input audio channel pair(See the example below.)
• ==aa==dd• aadd==dd• .....(all possible
combinations)
4, B Audio Mute Status [RO] Displays the mute status of embedded audio(See the example below.)
• ====• m===• =m==• ==m=• ===m• mm==• m=m=• m==m• =mm=• =m=m• ==mm• mmm=• m=mm• mm=m• =mmm• mmmm
Table 3-5. Control Parameters (Continued)
Bank, Rotary Switch
Parameter Name Function Options
Group 1 Group 2 Group 3 Group 4
aa dd
No audio present
Audio present
Datapresent
No audio present
All audio is embedded
Embedpair 1
Embedpair 2
Embedpair 3
Embedpair 4
All audio is muted
Mutepair 1
Mutepair 2
Mutepair 3
Mutepair 4
m m m m
HUC6800+ Installation and Operation Manual 45
Chapter 3: Operation
4, C Audio Bypass Feedback [RO]
Displays the bypass status of audio channels
• ====• b===• =b==• bb==• ==b=• b=b=• =bb=• bbb=• ===b• b==b• =b=b• bb=b• ==bb• b=bb• =bbb• bbbb
4, D Reference Video Standard Feedback [RO]
Displays the detected reference video standard
• Unknown• NTSC/PAL-M• TLS 720p59.94• TLS 1080i59.94• PAL-B• TLS 720p50• TLS 1080i50
4, E Valid Reference Video Standard [RO]
Indicates whether the detected reference video standard matches the selected output video standard
• No• Yes• Not applicable
4, F Reference Lock [RO] Indicates if system timing is locked to the reference input
• No• Yes• Not applicable
Bank 5
5, 1 Error Detection and Handling Present [RO]
Indicates the presence of EDH • Yes• No
Table 3-5. Control Parameters (Continued)
Bank, Rotary Switch
Parameter Name Function Options
46 HUC6800+ Installation and Operation Manual
Chapter 3: Operation
5, 2 EDH Error Count [RO] Displays the EDH error count 0 to 4,294,967,295
5, 3 Hardware Version [RO] Displays current hardware version String
5, 4 Firmware Version [RO] Displays current firmware version String
5, 5 to 5, F
Not available
Table 3-5. Control Parameters (Continued)
Bank, Rotary Switch
Parameter Name Function Options
HUC6800+ Installation and Operation Manual 47
Chapter 3: Operation
LEDs and Alarms
Monitoring LEDsThe HUC6800+ and HUC6800+C have 13 monitoring LEDs that serve as a quick monitoring reference. Figure 3-2 shows the location of the monitoring LEDs on a typical 6800+ module. Table 3-6 describes the meaning of the card-edge LEDs, from left to right.
Figure 3-2. Location of HUC6800+ and HUC6800+C LEDs
Module status LEDs
Monitoring LEDs
Table 3-6. LED Status Indicators
LED Description Color Indication50-59 Indicates the frame rate for the input video
standard• Green: 59• Off: 50
Auto Indicates the auto detection of the input video signal is activated
Green: Auto detect is enabled
525 Indicates the input standard is 525 Green: 525 input standard is detected
625 Indicates the input standard is 625 Green: 625 input standard is detected
720p Indicates the input standard is 720p Green: 720p input standard is detected
1080i Indicates the input standard is 1080i Green: 1080i input standard is detected
48 HUC6800+ Installation and Operation Manual
Chapter 3: Operation
Audio1 Reports the presence of audio group 1 in the input video stream
Green: Group 1 audio is present
Audio2 Reports the presence of audio group 2 in the input video stream
Green: Group 2 audio is present
Audio3 Reports the presence of audio group 3 in the input video stream
Green: Group 3 audio is present
Audio4 Reports the presence of audio group 4 in the input video stream
Green: Group 4 audio is present
CC Indicates the presence of closed captioning Green: Closed captioning data is present
Reference Indicates the presence of a valid reference signal Green: Valid signal is present
Bypass Indicates the bypass mode • Green - Bypass• Off - Normal
Table 3-6. LED Status Indicators (Continued)
LED Description Color Indication
HUC6800+ Installation and Operation Manual 49
Chapter 3: Operation
Module Status LEDsThe HUC6800+ and HUC6800+C modules do not have any card-edge alarms. Instead, module status LEDs on the corner of the module light up if an error is detected. See Figure 3-2 on page 48 for the location of these LEDs, and Table 3-7 for a definition of the LED colors.Alarms are usually logged and monitored within software control applications such as +PilotLite or CCS Pilot. See the appropriate software control user manual or online help for more information.
AlarmsTable 3-8 describes the specific alarms for HUC6800+ and HUC6800+C modules. You can only identify specific alarms using a software control application.
NoteIf the LED is flashing red, please contact your customer service representative.
Table 3-7. LED Color and Meaning
LED Color Sequence Meaning
Off There is no power to the module; the module is not operational.
Green There is power to the module; the module is operating properly.
Red There is an alarm condition.
Flashing Red The module has detected a hardware/firmware fault.
Amber The module is undergoing configuration.
Table 3-8. HUC6800+ Alarms
Alarm Name Alarm Description Alarm LevelSDI IP Video Present Loss of SDI input video Major
RefLockedAlarm Loss of locked reference Major
RefStdMismatch Mismatch between reference video and video standard
Major
50 HUC6800+ Installation and Operation Manual
Chapter 4
Specifications
OverviewThe following specification tables appear in this chapter:• “Inputs” on page 52• “Outputs” on page 53• “Upconverted HD-SDI Video” on page 54• “Audio Delay (Data Out)” on page 55• “Power Consumption” on page 55• “Operating Temperature” on page 55Specifications and designs are subject to change without notice.
HUC6800+ Installation and Operation Manual 51
Chapter 4: Specifications
InputsSD/HD-SDI Video
Genlock
Table 4-1. SD/HD-SDI Video Input Specifications
Item SpecificationNumber of inputs 1
Standards • SMPTE 259M-C (525/625)• SMPTE 292M (1080i/720p)
Frame rate • 486i: 59.94 Hz• 576i: 50 Hz• 1080i: 50, 59.94 Hz• 720p: 50, 59.94 Hz
Connector BNC per IEC 169-8
Impedance 75Ω
Return loss >15 dB (typical) to 1485 MHz
Equalization 270 m (typical) Belden 8281 cable at 270 Mbps; adaptive cable equalization for up to 377 ft (115m) (typical) of Belden 1694A coaxial cable at 1.485 Gbps
Table 4-2. Genlock Input Specifications
Item SpecificationConnector BNC per IEC 169-8
Impedance 75Ω
Return loss • >40 dB (typical) to 6 MHz• >35 dB (typical) to 30MHz
Input level • NTSC/PAL-B (1 V pk-to-pk, -5.0 dB to 6.0 dB)• Tri-Level Sync (1080i/720p) ± 300 mV, -3.5 dB to
6.0 dB
Signal type • NTSC/PAL-B analog composite• ± 300 mV Tri-Level Sync (1080i/720p)
52 HUC6800+ Installation and Operation Manual
Chapter 4: Specifications
Outputs
SD/HD-SDI Reclocked Video
Table 4-3. SD/HD-SDI Reclocked Output Specifications
Item SpecificationNumber of outputs 2
Standards • SMPTE 259M-C (525i/625i)• SMPTE 292M (1080i/720p)
Connector BNC per IEC 169-8
Impedance 75Ω
Return loss >15 dB (typical) to 1485 MHz
DC offset 0.0 V ± 0.5 V
Signal level 800 mV ± 10%
Rise and fall time <270 ps at 1.485 GHz; 400 ps to 1500 ps at 270 MHz
Overshoot <10% of amplitude
Jitter • Timing (<0.2 UI at 270 MHz)• Alignment (<0.2 UI at 270 MHz)• Timing (<1 UI at 1.485 GHz)• Alignment (<0.2 UI at 1.485 GHz)
HUC6800+ Installation and Operation Manual 53
Chapter 4: Specifications
Upconverted HD-SDI Video
Table 4-4. Upconverted HD-SDI Video Output Specifications
Item SpecificationNumber of outputs 2 program, 2 monitor/program
Standards SMPTE 292M (1080i/720p)
Connector BNC per IEC 169-8
Impedance 75Ω
Return loss >15 dB (typical) to 1485 MHz
DC offset 0.0 V ± 0.5 V
Signal level 800 mV ± 10%
Rise and fall time <270 ps at 1.485 GHz
Overshoot <10% of amplitude
Jitter • Timing (<1 UI at 1.485 GHz)• Alignment (<0.2 UI at 1.485 GHz)
54 HUC6800+ Installation and Operation Manual
Chapter 4: Specifications
Miscellaneous
Audio Delay (Data Out)
Power ConsumptionThe HUC6800+ and HUC6800+C each have a power consumption of less than 10.5 W.
Operating TemperatureThe operating temperature for HUC6800+ and HUC6800+C modules is 41° to 113°F (5° to 45°C).
Table 4-5. Audio Delay Specifications
Item SpecificationNumber of outputs 1
Connector BNC per IEC 169-8
Impedance 75Ω
Return loss >20 dB (typical) to 6 MHz
HUC6800+ Installation and Operation Manual 55
Chapter 4: Specifications
56 HUC6800+ Installation and Operation Manual
Appendix A
Communication and ControlTroubleshooting Tips
OverviewFind the following troubleshooting information in this appendix:• “General Troubleshooting Steps” on page 58• “Software Communication and Control Issues” on page 59• “Hardware Communication and Control Issues” on page 63• “Contacting Customer Service” on page 63
HUC6800+ Installation and Operation Manual 57
Appendix A: Communication and Control Troubleshooting Tips
General Troubleshooting StepsFollow these steps in troubleshooting 6800+ product problems:1. Review the “Software Communication and Control Issues” on
page 59 outlined in this chapter.2. Search this product manual and other associated documentation for
answers to your question.Product documentation (including manuals, online help, application notes, erratas, product release notes, and more) can be found on our Web site at www.broadcast.harris.com/leitch (Support section), along with technical support information, training information, product downloads, and the product knowledge base.
3. Contact your product Customer Service representative if, after following these initial steps, you cannot resolve the issue.To contact your product Customer Service, see “Contacting Customer Service” on page 63.
NoteAssociated documentation for 6800+ series products can generally be found in the product-specific manual that accompanies every module, in the FR6802+ Frame Installation and Operation Manual, and in the 6800+ Safety Instructions and Standards Manual.
58 HUC6800+ Installation and Operation Manual
Appendix A: Communication and Control Troubleshooting Tips
Software Communication and Control Issues• “+ Pilot Lite Fails to Communicate with Installed Modules” on
page 59• “+ Pilot Lite Does Not Find All Modules in Frame” on page 60• “+ Pilot Lite or CCS Software Application Not Responding” on
page 61• “+ Pilot Lite Cannot Control a Module Showing
in the Control Window” on page 61• “+ Pilot Lite Status Bar Reports ‘Not Ready’” on page 61• “CCS Software Application or Remote Control Panel Does Not
Communicate with Module” on page 62• “Alarm Query Fails When a Device Reboots” on page 62
+ Pilot Lite Fails to Communicate with Installed ModulesConfirm that the following items are not the reason for the communication failure:• Proper module slot has not been specified (+ Pilot Lite is not
communicating with the appropriate slot). See your FR6802+ Frame Installation and Operation Manual for more information on slot identification.
• COM port is used elsewhere (Check that the correct COM port is configured in + Pilot Lite and that another application is not using that COM port).
• Actual frame ID does not match with the two DIP switch settings in the back of the frame (+ Pilot Lite is not communicating with the proper frame). See your FR6802+ Frame Installation and Operation Manual for more information on frame ID switch settings.
• Null modem cable is not being used. Between the PC running + Pilot Lite and the FR6802+ frame, there should be a null RS-232 modem cable. At minimum, this requires that pins 2 and 3 are crossed and 5 to 5 for ground.
• ICE6800+ module is installed in the frame (+ Pilot Lite control is disabled if an ICE6800+ module is installed in the frame; ICE6800+ modules are used for CCS control).
HUC6800+ Installation and Operation Manual 59
Appendix A: Communication and Control Troubleshooting Tips
• A legacy 6800 series product is in the frame. + Pilot Lite cannot communicate with legacy 6800 series products. They will not be discovered or controlled by + Pilot Lite, although they can be installed in the FR6802+ frame and work using card edge controls. The module must be from the 6800+ product family.
• Check that the back module does not have any bent pins. Follow this procedure:a. Unplug the front module first b. Unscrew and remove the back module.c. View the 30-pin spring connector at the bottom of the back
module. See Figure A-1.
Figure A-1. Connector on 6800+ Back Module
This connector should not have any bent or pressed pins. Even a slightly depressed or bent pin may cause genlock issues.
d. If there are bent pins, carefully re-position them to their correct positions. If this is not possible, a back module can be obtained from the manufacturer.
+ Pilot Lite Does Not Find All Modules in FrameIf a discovery is started too soon after frame power-up, + Pilot Lite will not find all the installed modules. Refresh + Pilot Lite (File > Refresh), and ensure that installed modules are fully powered-up first before discovery.
30-pin connector
60 HUC6800+ Installation and Operation Manual
Appendix A: Communication and Control Troubleshooting Tips
If a module is plugged into the frame after a discovery, + Pilot Lite does not automatically detect the module. Refresh + Pilot Lite (File > Refresh) to discover the newly installed module.If a Legacy 6800 series product is in the frame, + Pilot Lite will not detect it. + Pilot Lite cannot communicate with legacy 6800 series products. They will not be discovered or controlled by + Pilot Lite although they can be installed in the FR6802+ frame and work using card edge controls. For + Pilot Lite to find a module, it must be from the 6800+ product family.
+ Pilot Lite or CCS Software Application Not Responding+ Pilot Lite and CCS applications such as Navigator or Pilot cannot run on the same PC at the same time. Both applications can be installed, but only one can be opened at a time.
+ Pilot Lite Cannot Control a Module Showing in the Control Window
Consider these questions:• Did you physically set the jumper for local control? If so, set this
jumper to the REM position for remote control.• Does the card name in the control window physically match the
card type in the frame? • Is the module properly seated in the frame? Check the positioning
of the module in its slot in the frame.• Does the Control window indicate the device is “ready”? The
device may be powered off or disconnected from the network.
+ Pilot Lite Status Bar Reports ‘Not Ready’+ Pilot Lite reports each device’s connection status in the status bar. If the connection status message reads “Not Ready,” check the following:• Is the module properly seated in the frame? Check the position of
the module in the frame.• Is the frame connected to the network? Check the device’s network
connection.If the status bar still reports no status or “Not Ready” for the frame or device, try restarting + Pilot Lite.
HUC6800+ Installation and Operation Manual 61
Appendix A: Communication and Control Troubleshooting Tips
CCS Software Application or Remote Control Panel Does Not Communicate with Module
CCS software applications (such as Pilot, CoPilot, and Navigator) and remote control panels require the purchase and installation of an ICE6800+ module in an FR6802+ frame in order to communicate remotely via Ethernet.
Alarm Query Fails When a Device RebootsWhen you reboot a device connected to your PC, the alarm traffic hitting the network may cause an alarm query request to time out and fail. While the query does not automatically retry, it will post an “Alarm query failed” message to the Diagnostics window.To clear an “Alarm query failed” message, right-click inside the Diagnostics window, and then select Refresh from the resulting context menu.
62 HUC6800+ Installation and Operation Manual
Appendix A: Communication and Control Troubleshooting Tips
Hardware Communication and Control Issues• “Frames Fail to Communicate with the PC after a Power Failure”
on page 63• “Module Does Not Seem to Work” on page 63
Frames Fail to Communicate with the PC after a Power Failure
Have you exited the software and restarted since the frame recovered from its power failure? To restore communications between the PC and the frames, ensure that the frames have three or more minutes to recover from the power failure before you exit the application and restart the PC.
Module Does Not Seem to WorkAlthough the following troubleshooting tips may seem obvious, please take the time to ensure the following:• All appropriate rear connections are securely made• The board is securely installed (with no bent pins)• The frame is turned on
Contacting Customer ServiceWe are committed to providing round-the-clock, 24-hour service to our customers around the world. Visit the Support section of our Web siteat www.broadcast.harris.com/leitch for information on how to contact the Customer Service team in your geographical region.
HUC6800+ Installation and Operation Manual 63
Appendix A: Communication and Control Troubleshooting Tips
64 HUC6800+ Installation and Operation Manual
Index
KeywordsAAdd Upgrade Files box 20alarm query failure 62alarms list 50application not responding 61ARC Preset Select parameter 28–30ARC_Ovrscn parameter 31aspect ratio conversion (ARC) 28–31audio delay specifications 55audio sync and delay 26
Bback connectors 6
CCCS applications 57–63connectors, back module 6contacting customer service 63control and communication problems 57–63control parameters 36–47correcting failed upgrades 18cross-functional parameter changes 35custom aspect ratios 28, 30customer service, contacting 63
Ddefault parameter settings 34, 36delay, audio and video 24–26discovery failure 60–61drag-and-drop method of upgrading 17
Ffailure to communicate 63firmware upgrading 15–21frame power ratings 10functional block diagram 6–7
Ggenlock specifications 52
HHD-SDI video input and output specifications 53
IInput Frame Delay parameter 26Input Video Standard parameter 27installing and removing modules 14
Jjumper settings 12–13
HUC6800+ Installation and Operation Manual 65
Index
LLED descriptions 48–50
Mmain features 2manual information vii–viiimodule
installation and removal 14not found 60status LEDs 50
monitoring LEDs 48–49
NNavigation Properties box 18, 20not ready status 61
Oon screen display (OSD) 34, 36operating notes 24operating temperature specifications 55Output Video Standard parameter 27overscan mode 31
Ppacking list 11parameter settings 33parameters
ARC H Offset and ARC V Offset 28–30ARC H Scale and ARC V Scale 28–30ARC Preset Select 28–30ARC_Ovrscn 31Input Frame Delay 26Input Video Standard 27On Screen Display 34Output Video Standard 27
powerconsumption specifications 55failure 63ratings, frames 10
precautions, safety xiiproduct servicing ixpropagation delay 24–25
Rreboot device 62recalling
default parameter settings 34saved aspect ratio 30
removing and installing modules 14returning a product ixrevision history of the manual viiRoHS-compliance x
Ssafety precautions xiisaving a custom aspect ratio 30SD/HD-SDI
reclocked video output specifications 53video input specifications 52
setting jumpers 12–13shipping and unpacking a product ixsignal flow 6–7software upgrading 15–21specifications 52–55
audio delay 55genlock 52operating temperature 55power consumption 55SD/HD-SDI
reclocked video output 53video input 52
upconverted HD-SDI video output 54standard aspect ratios 28standards
RoHS compliance xWEEE compliance xi
status, “not ready” 61support documents viiisynchronization, audio and video 24
66 HUC6800+ Installation and Operation Manual
Index
Ttrademarks and copyrights iitroubleshooting 57–63
Uunpacking and shipping a product ixupconverted HD-SDI video output specifications 54upgrading module software 15–21
Vvideo frame
sync and delay 26synchronizer 24
Wwarranty information iiWEEE compliance xiwriting conventions viii
HUC6800+ Installation and Operation Manual 67
Index
68 HUC6800+ Installation and Operation Manual
Broadcast Communications Division 4393 Digital Way | Mason, OH USA 45040 | Tel: 1 (513) 459 3400
www.broadcast.harris.com
Copyright © 2006 Harris Corporation
Harris and Leitch are registered trademarks of Harris Corporation. Trademarks and tradenames are the property of their respective companies.