High Voltage for Ship

Generation, Conversion ,

Transformation and Distribution

Page 2: Hv genration   transpformation - converson & distribution - revisedl

Marine Electrical System • Maritime electric systems include power generation, distribution and

control, and consumption of electric power on supply- service- and fishing vessels as well as offshore installations.

• Electric propulsion has increased especially for vessels with several large

power consumers, for example cruise ships, floating production systems,

supply- and service vessels.

• Maritime electric systems are autonomous power systems. The prime movers, including diesel engines, gas- and steam turbines, are integral parts of the systems.

• The power consumers are large compared with the total capacity of the system, as for example thruster and propulsion systems for DP operated vessels, drilling systems, HVAC systems on board ship

Page 3: Hv genration   transpformation - converson & distribution - revisedl

Marine Electrical System

• The overall power train efficiency with DEP is around 87-90%. Use of permanent magnets in electric generators and motors as well as general advances in semiconductor technology may improve this figure to around 92-95% in the near future. Electrical transmission will consist of three basic energy conversions:

• From (rotating) mechanical energy into electrical energy: E-generator

• From electrical energy into (rotating) mechanical energy: E-motor

• Some form of fixed or controlled electrical conversion in between: power converter

Page 4: Hv genration   transpformation - converson & distribution - revisedl

Systematic overview of existing types

E-generator

• Mechanical ==> Electrical: E-Generators

• - DC Generators

• - AC Generators

E-Motors

• Electrical ==> Mechanical: E-motors

• - Driving motors

• - Synchronous Motor

• - Positioning motors

Power converters

Electrical ==> Electrical: power conversion or transformation

• - Fixed transformers

• - Controlled converters

• - Static converters

• -Inverter

Page 5: Hv genration   transpformation - converson & distribution - revisedl

Structure of a combined power plant

for ships

Page 6: Hv genration   transpformation - converson & distribution - revisedl

Electric Propulsion System (AES)

• Electric propulsion of ships has been know for a long time to human

• Dynamic changes in human discovery has given several up and down in history

• Recent time have seen a a lot of Passenger ships being built with all electric system for various advantage that over the conventional prime movers

• Early large passenger vessels employed the turboelectric system which involves the use of variable speed, and therefore variable frequency, turbo-generator sets for the supply of electric power to the propulsion motors directly coupled to the propeller shafts. Where, the generator/motor system was acting as a speed reducing transmission system.

• Electric power for auxiliary ship services required the use of separate constant frequency generator sets. System with generating sets to provide power to both the propulsion system and ship ancillary services.

• However fixed voltage and frequency system are suitable to satisfy the requirements of the ship service loads.

Page 7: Hv genration   transpformation - converson & distribution - revisedl

Marine Electrical System

Page 8: Hv genration   transpformation - converson & distribution - revisedl

Electric Propulsion System (AES)• Other complication associated with earlier systems is difficulties in using multiple

motor per shaft when required propulsion power was beyond the capacity of a single d.c. motor .

• Developments in high power static converter equipment have – presented a very convenient means of providing variable speed a.c. and d.c. drives at the largest ratings likely to be required in a marine propulsion system.

• The electric propulsion of ships requires electric motors to drive the propellers and generator sets to supply the electric power. It may seem rather illogical to use electric generators, switchgear and motors between the prime-movers (e.g. diesel engines) and propeller when a gearbox or length of shaft could be all that is required.

• In the light of the above, hybrid of gas turbine or Diesel with electric couple with dual fuelling that include natural gas, is explorable option for existing vessels, all electric ship using natural gas is also a good option.

• Currently there is interesting development for new ship need exploration on

technologies to improve integrated full electric propulsion with advanced power

management systems:

• Improved converter and power electronics technology

• Improved generators and motors

Page 9: Hv genration   transpformation - converson & distribution - revisedl

Electric Propulsion System (AES)

• The AES give widespread electrification of auxiliaries and the opportunity to use upgradeable and flexible layouts. It will include a low risk, cost effective and comprehensive Platform Management System that has a standardized Human-Computer Interface supportable for its entire service life and the goal to be an Environmentally Sound Ship.

• The fit into the goals of the Environmentally Sound Ship where : freedom of operation in MARPOL special and restricted areas; unrestricted littoral operations; port independence; minimum onboard storage of waste and reduced manpower whilst reducing cost of ownership and port reception costs.

• the also promise potential for replacing the current traditional systems used in steering gear, fin stabilizers with compact, power-dense actuators.

• They also offer potentials for possible use of electric valve actuators that will simplify system architectures systematic integration of upper deck to machinery.

Page 10: Hv genration   transpformation - converson & distribution - revisedl

Power generation

• A 2001 study concluded that fitting a Navy cruiser with more energy-efficient electrical equipment could reduce the ship’s fuel use by 10% to 25%.

• Ship fuel use could be reduced by shifting to advanced turbine designs such as an intercooled recuperated (ICR) turbine. Shifting to integrated electric-drive propulsion can reduce a ship’s fuel use by 10% to 25%.

• There is Potential alternative hydrocarbon fuels Like biodiesel and liquid hydrocarbon fuels made from coal

• Recent time has seen firms offering kite-assist systems to commercial ship operators.

• Solar power might offer some potential for augmenting other forms of shipboard power.

• Talking about the question now the electric propulsion , especially with hybrid system offer the best answer to problem of energy

Page 11: Hv genration   transpformation - converson & distribution - revisedl

Power generation

• Integrated electric-drive system derived from a commercially available system that has been installed on ships such as cruise ships requires a technology that is more torque-dense (i.e., more power-dense) .

• Candidates for a more torque-dense technology include a permanent magnet motor (PMM) and a high-temperature superconducting (HTS) synchronous motor.

• In addition, electric drive makes possible the use of new propeller/stern configurations, such as a podded propulsion ... that can reduce ship fuel consumption further due to their improved hydrodynamic efficiency

• Podded drives offer greater propulsion efficiency and increased space within the hull by moving the propulsion motor outside the ships hull and placing it in a pod suspended underneath the hull.

• Podded drives are also capable of azimuth improving ship maneuverability. Indeed, podded drives have been widely adopted by the cruise ship community for these reasons.

• The motors being manufactured now are as large as 19.5 MW, and could provide the total propulsion power.

Page 12: Hv genration   transpformation - converson & distribution - revisedl

Azipod drive unit

Page 13: Hv genration   transpformation - converson & distribution - revisedl

Comparison of propulsion plants

efficiency

Page 14: Hv genration   transpformation - converson & distribution - revisedl

Weight of propulsion systems

Page 15: Hv genration   transpformation - converson & distribution - revisedl

Prime moversGas Turbines

• Gas turbine have been selected as the future prime mover primarily because of their high power to weight ratio.

• 4. Weight sensitive ship designs favor gas turbines and projected light weight fuel cell power plants such as PEM.

• They also provide significant reduction in the amount of routine maintenance required when compared with diesel generators.

• The other significant factor is the low emissions.

Diesel engine

• Diesel engines offer fuel costs savings of 50% if heavy fuels can be used, and if emissions can be maintained at acceptable levels.

• Maintenance may include engine modifications such as dual fuel capability for in-port use, water injection, and timing retard, and exhaust treatment such as selected catalytic reduction and oxidation catalysts.

• Heavy fuel use also requires careful selection of cylinder material and lube oil

Page 16: Hv genration   transpformation - converson & distribution - revisedl

Turbina

• A gas turbine, also called a combustion turbine, is a rotary engine that extracts energy from a flow of hot gas produced by combustion of gas or fuel oil in a stream of compressed air.

• It has an upstream air compressor radial or axial flow mechanically coupled to a downstream turbine and a combustion chamber in between.

• Energy is released when compressed air is mixed with fuel and ignited in the combustor.

• The resulting gases are directed over the turbine's blades, spinning the turbine, and, mechanically, powering the compressor.

• Finally, the gases are passed through a nozzle, generating additional thrust by accelerating the hot exhaust gases by expansion back to atmospheric pressure.

• A steam turbine is a mechanical device that extracts thermal energy from pressurized steam, and converts it into useful mechanical work.

Page 18: Hv genration   transpformation - converson & distribution - revisedl

Steam engine

Page 19: Hv genration   transpformation - converson & distribution - revisedl

COGAG

• Combined gas turbine and gas turbine (COGAG) is propulsion system for ships using two gas turbines connected to a single propeller shaft.

• A gearbox and clutches allow either of the turbines to drive the shaft or both of them combined.

• Using one or two gas turbines has the advantage of having two different power settings.

• Since the fuel efficiency of a gas turbine is best near its maximum power level, a small gas turbine running at its full speed is more efficient compared to a twice as powerful turbine running at half speed, allowing more economic transit at cruise speeds.

Page 21: Hv genration   transpformation - converson & distribution - revisedl

Prime moversElectric drive

• Electric drive transmissions have a higher specific fuel consumption, specific weight and volume than mechanical drive systems, but has advantages in arrangement which may compensate for these disadvantages.

• Advanced technology motors can be located very close to and on line with the propulsors, at the extreme aft end of the ship, or in external pods.

• Electrical generator sets can be optimally spaced around the ship and electrically connected. In the longer term, combined with fuel cells, SFC, specific weight and volume are comparable with gas turbine and diesel prime movers for direct drive systems.

Zone Concept :

• The concept of dividing future classes of ship into zones to maximize survivability also extends to the power system.

• Each zone would be autonomous and include ventilation systems, cooling systems, power distribution and other services which could be affected by damage to another part of the ship.

• At least two supplies would be provided for all essential loads. Current classes, using split generation and distribution, rely on the provision of normal and alternative supplies via Automatic Change-Over Switches

Page 22: Hv genration   transpformation - converson & distribution - revisedl

Typical system with zoning

Page 23: Hv genration   transpformation - converson & distribution - revisedl

Fuel cell

• The fuel cell stack operates by utilizing electrochemical reactions between an oxidant (air) and a fuel (hydrogen), with two electrodes separated by a membrane.

• The voltage of the fuel cell output can be controlled by a converter and it is therefore able to connect to any point in the ship service or propulsion distribution system.

• The fuel cell stack is modularity give redundancy advantage. It also has the additional advantages of zero noxious emissions, and low thermal and acoustic signatures.

• In the short term the fuel cell system is required to use marine diesel fuel. Diesel fuel will require reforming within the fuel cell stack, or using an external process, to produce a hydrogen rich gas which the fuel cell stack is capable of processing.

• The reformer will clearly add both size, weight and complexity to the fuel cell system. In the longer term technologies such as the Solid Oxide Fuel Cell (SOFC) are contenders, which are more forgiving of impurities and can use a fuel available world-wide, either methanol or gasoline.

Page 24: Hv genration   transpformation - converson & distribution - revisedl

Storage option

• The technologies being assessed for energy storage include are electro-chemical batteries (both conventional and advanced), regenerative fuel cells (otherwise known as redox flow cells ) Superconducting Magnetic Energy Storage (SMES) and Supercapacitors.

• Regenerative fuel cells store or release electrical energy by means of a reversible electrochemical reaction between two salt solutions (the electrolytes). The reaction occurs within an electrochemical cell.

• The cell has two compartments, one for each electrolyte, physically separated by an ion-exchange membrane.

• In contrast to most types of battery system, the electrolytes flow into and out of the cells and are transformed electrochemically inside the cells. The power is therefore determined by the size of the cell but the endurance is determined by the size of the two electrolyte tanks

Page 25: Hv genration   transpformation - converson & distribution - revisedl

Storage system

Page 26: Hv genration   transpformation - converson & distribution - revisedl

Prime movers

• All primemovers are potentially compliant with emerging emission requirements, however, complexity for achieving compliance varies with prime mover and fuel type.

• Diesels require the most attention to emissions control followed at some distance by gas turbines, where ultra low emissions levels have been achieved for land-based systems.

• Fuel cells emit the lowest levels of pollutants of all the primemovers

• Heavier fuel cell systems and diesels represent larger machinery and structural weight.

• Fuel cells can be used as a prime mover in an Integrated Full Electric Propulsion (IFEP) system providing DC electrical power output, and are being developed as a replacement for diesel generators and gas turbine alternators.

Page 27: Hv genration   transpformation - converson & distribution - revisedl

Sail and solar power ship

Page 28: Hv genration   transpformation - converson & distribution - revisedl

Skysail

Page 29: Hv genration   transpformation - converson & distribution - revisedl

Propulsion motor• For efficient operation of propulsion motor there is a

requirement for a compact, power dense, rugged electrical machine to be utilized for the propulsion motor.

• For the full benefits of electric propulsion to be realized the machine should also be efficient, particularly at part load,

• In order to achieve suitable compact designs rare earth permanent magnet materials may be required.

• The machine topologies available for PMM are deemed to be those based on radial, axial and transverse flux designs.

Page 30: Hv genration   transpformation - converson & distribution - revisedl

PMM

Page 31: Hv genration   transpformation - converson & distribution - revisedl

Power for LNG ships

• These alternatives are more economical and offer greater overall efficiency with an added advantage of providing greater flexibility and redundancy

• Diesel plant also raises are inherited with problem of vibration on membrane

• LNG carrier it is necessary to understand the interaction between the structural resonance that is excited by the diesel engine and the separate resonance that is created within the membrane containment system interacting with LNG.

• The traditional application of gas fired boilers for steam turbine propulsion systems is no longer the only available option for LNG Carriers,”

• Direct drive, slow speed diesel plants, coupled with an on-board liquefaction plant to handle the cargo boil off, or 4 stroke medium speed diesel electric propulsion or gas turbine with diesel electric drive appear to offer the greatest operational efficiencies for the new designs of large LNG carriers.

Page 32: Hv genration   transpformation - converson & distribution - revisedl

Power generation for LNG ships

• Although slow or medium speed diesel engines have been selected for some of the recent LNG carriers with dual fuel installation option that uses both gas boil-off and ordinary bunkers.

• Variations of the dual fuel arrangements include:

-diesel engine or gas turbine driven generators with one propulsion shafting system and a liquefaction plant;

-diesel engine or gas turbine driven generators with two propulsion shafting systems and a liquefaction plant;

-diesel engine or gas turbine driven generators with two azimuth thrusters and a liquefaction plant.

• To date, slow speed diesel with re-liquefaction plant as well as a gas combustion unit, and medium speed dual fuel diesel with gas combustion units, are the preferred options for the new large LNG carriers recently ordered in Korea.

• It would appear that gas turbine with simple and combined cycles using heat recovery units to drive steam turbo alternators are another alternative being explored. Industry is currently developing the fuel gas systems for these gas turbine options.

Page 33: Hv genration   transpformation - converson & distribution - revisedl

Power generation for LNG ships

• A dual fuel diesel-electric system uses forced boil-off from the cargo tanks as the primary fuel and marine diesel oil as back-up fuel. The arrangement can also be adapted to current LNG carrier designs.

• Shipbuilders and engine designers that are proponents of dual fuel systems point out that a gas-electric propulsion plant is more compact than the traditional steam turbine plant used for LNG carriers, increasing cargo capacity within the same dimensioned hull.

• The IMO Gas Carrier Code requires two means of utilizing boil-off gas on all LNG carriers. Conventional systems use the main boilers for generating steam for propulsion. When this cannot be used, excess steam is redirected to the condensers. Similar arrangements are required for the diesel propulsion systems. Current industry proposals for the alternative means of boil-off gas utilization are a liquefaction plant or a gas combustion unit.

• Risk assessment methods are recommended for option selection

Page 34: Hv genration   transpformation - converson & distribution - revisedl

Power Distribution

• As the demand for electrical are 3.3 kV or 6.6 kV but 11 kV is used on some offshore platforms and specialist oil/gas production ships e.g on some FPSO (floating production, storage and offloading) vessels.

• By generating electrical power at 6.6 kV instead of 440 V the distribution and switching of power above about 6 MW becomes more manageable.

• As for electrical Power increases on ships (particularly passenger ferries, cruise liners, and specialist offshore vessels and platforms) the supply current rating becomes too high at 440 V.

• To reduce the size of both steady state and fault current levels, it is necessary to increase the system voltage at high power ratings.

Page 35: Hv genration   transpformation - converson & distribution - revisedl

Component parts of an HV

• The component parts of an HV supply system are standard equipment with:

HV diesel generator sets feeding an HV main switchboard.

• Large power consumers such as thrusters, propulsion motors, air-conditioning (A/C) compressors and HV transformers are fed directly from the HV switchboard.

• An economical HV system must be simple to operate, reasonably priced and require a minimum of maintenance over the life of the ship.

• Experience shows that a 9 MW system at 6.6 kV would be about 20% more expensive for installation costs.

• The principal parts of a ships electrical system operated at HV would be the main generators, HV switchboard, FV cables, HV transformers and HV motors.

• An example of a high voltage power system is shown

Page 36: Hv genration   transpformation - converson & distribution - revisedl

Ship HV Voltage system

Page 37: Hv genration   transpformation - converson & distribution - revisedl

HV Systems• In the example shown the HV generators form a central power station for

all of the ship's electrical services.

• On a large passenger ship with electric propulsion, each generator may be rated at about 10 MW or more and producing 6.6 kV, 60 Hz three-phase a.c. voltages.

• The principal consumers are the two synchronous a.c. propulsion electric motors (PEMs) which may each demand 12 MW or more in the full away condition.

• Each PEM has two stator windings supplied separately from the main HV switchboard via transformers and frequency converters.

• In an emergency a PEM may therefore be operated as a half-motor with a reduced power output. A few large induction motors are supplied at 6.6 kV from the main board with the circuit breaker acting as a direct-on-line (DOL) starting switch.

Page 38: Hv genration   transpformation - converson & distribution - revisedl

Ship high voltage systems These motors are:

o Two forward thrusters and one aft thruster, and

o Three air conditioning compressors

• Other main feeders supply the 440 V engine room sub-station (ER sub) switchboard via step-down transformers.

• An interconnector cable links the ER sub to the emergency switchboard.

• Other 440 V sub-stations (accommodation,galley etc.) around the ship are supplied from the ER sub.

• Some installations may feed the ships sub stations directly with HV and step-down to 440 V locally.

• The PEM drives in this example are synchronous motors which require a controlled low voltage excitation supply current to magnetise the rotor poles.

• This supply is obtained from the HV switchboard via a step-down transformer but an alternative arrangement would be to obtain the excitation supply from the 440 V ER sub switchboard.

Page 39: Hv genration   transpformation - converson & distribution - revisedl

Ship high voltage systems

Page 40: Hv genration   transpformation - converson & distribution - revisedl

High Voltages solid state AC-

DC-AC conversion

Page 41: Hv genration   transpformation - converson & distribution - revisedl

Solid State Switching Principle

• The power systems engineers is interested in high voltages primarily for power transmission, and secondly for testing of his equipment used in power transmission in laboratory

• High voltage can be obtained locally from power generating plant through the use of solid state

• In many testing laboratories, the primary source of power is at low voltage (400 V three phase or 230 V single phase, at 50 Hz). From which high voltage can be obtained

• On board ship the same technology can be used to use high voltage

• Laboratory test are aimed to design the required high voltage

• Since insulation is usually being tested, the impedances involved are extremely high (order of M ohm and the currents small (less than an ampere).

• High voltage testing does not usually require high power.

• Thus special methods may be used which are not applicable when generating high voltage in high power applications.

Page 42: Hv genration   transpformation - converson & distribution - revisedl

Solid State Switching Principle• In the field of electrical eng. & applied physics, high voltages are required for

several applications As:

-a power supply (eg. hv dc) for the equipments such as electron microscope and x-ray machine.

-Required for testing power apparatus – insulation testing.

-High impulse voltages are required for testing purposes to simulate over voltages due to lightning and switching.

• Sometimes, high direct voltages are needed in insulation test on cables and capacitors. Impulse generator charging units also require high dc voltages of about 100-200kV.

• Normally for the generation of dc voltages of up to 100kV, electronics valve rectifiers are used and the output currents are about 100mA. The rectifier valves require special construction for cathode and filaments since a high electrostatic field of several kV/cm exists between the anode and cathode in the non-conduction period.

• The ac supply to the rectifier tubes maybe of power frequency or maybe of audo frequency from an oscillator. The latter is used when a ripple of very small magnitude is required without the use of costly filters to smoothen the ripple.

Page 43: Hv genration   transpformation - converson & distribution - revisedl

Half and Full Wave Rectifier

• Rectifier circuits for producing high dc voltages from ac sources maybe

a. Half-Wave

b. Full-Wave

o The rectifier can be an electron tube or a solid state devices. Nowadays, single electron tubes are available for peak inverse voltages up to 250kV and semiconductor or solid state diodes up to 250kV.

o For higher voltages, several units are to be used in series. When a number of units are used in series, transient voltage distribution along each unit becomes non-uniform and special care should be taken to make the distribution uniform.

Page 44: Hv genration   transpformation - converson & distribution - revisedl

V outVinR

L

Half Wave Rectifier

V AVG

Vp

0

T

Mean Load Voltage or Average Value of half wave output

Page 45: Hv genration   transpformation - converson & distribution - revisedl

R L

to t1t2to t1

+

-

D 1

D 2

figure 1.7 : Full-wave rectifier circuit

t ot1 t2

Vp

V AVG

Full wave Rectifier Circuit

Mean Load Voltage or Average Voltage Full-wave output

Page 46: Hv genration   transpformation - converson & distribution - revisedl

Voltage Multiplier Circuits

• Both full-wave as well as half-wave circuits can produce a maximum direct voltage corresponding to the peak value of the alternating voltage.

• When higher voltages are required voltage multiplier circuits are used. The common circuits are the voltage double circuit

• Used for higher voltages.

• Generate very high dc voltage from single supply transformer by extending the simple voltage doubler circuit.

Page 47: Hv genration   transpformation - converson & distribution - revisedl

Types of high voltages;

• High d.c. voltages

• High a.c. voltages of power frequency

• High a.c. voltages of high frequency

• High transient or impulse voltages of very short

• duration - lightning overvoltages

• Transient voltages of longer duration – switching

• surges

Page 48: Hv genration   transpformation - converson & distribution - revisedl

• The voltage doubler circuit makes use of the positive and the negative half cycles to charge two different capacitors. These are then connected in series aiding to obtain double the direct voltage output. Figure shows a voltage doubler circuit.

• In this case, the transformer will be of small rating that for the same direct voltage rating with only simple rectification. Further for the same direct voltage output the peak inverse voltage of the diodes will be halved.

Voltage doubler circuit

Page 49: Hv genration   transpformation - converson & distribution - revisedl

High Alternating Voltages

• Required in laboratories and a.c. tests as well as for the

• circuit of high d.c. and impulse voltage.

• Test transformer are generally used.

• Single transformer test units are made for high alternating voltages up to about 200 kV.

• However, for high voltages to reduce the cost (insulation cost increases rapidly with voltage) and make transportation easier, a cascade arrangement of several transformers is used.

• For higher voltage requirement, series connection or cascading of the several identical units of transformer is applied.

Page 50: Hv genration   transpformation - converson & distribution - revisedl

Cascade arrangement of

transformers

Page 51: Hv genration   transpformation - converson & distribution - revisedl

1600 kV, 9.6 MVA Cascaded Power Transformer

Page 52: Hv genration   transpformation - converson & distribution - revisedl

• A typical cascade arrangement of transformers used to obtain up to 300 kV from three units each rated at 100 kV insulation. The low voltage winding is connected to the primary of the first transformer, and this is connected to the transformer tank which is earthed.

• One end of the high voltage winding is also earthed through the tank.

• The high voltage end and a tapping near this end is taken out at the top of the transformer through a bushing, and forms the primary of the second transformer.

• One end of this winding is connected to the tank of the second transformer to maintain the tank at high voltage.

• The secondary of this transformer too has one end connected to the tank and at the other end the next cascaded transformer is fed.

Cascade arrangement of transformers

Page 53: Hv genration   transpformation - converson & distribution - revisedl

• This cascade arrangement can be continued further if a still higher voltage is required.

• In the cascade arrangement shown, each transformer needs only to be insulated for 100 kV, and hence the transformer can be relatively small. If a 300 kV transformer had to be used instead, the size would be massive. High voltage transformers for testing purposes are designed purposely to have a poor regulation.

• This is to ensure that when the secondary of the transformer is short circuited (as will commonly happen in flash-over tests of insulation), the current would not increase to too high a value and to reduce the cost. In practice, an additional series resistance (commonly a water resistance) is also used in such cases to limit the current and prevent possible damage to the transformer.

Cascade arrangement of transformers

Page 54: Hv genration   transpformation - converson & distribution - revisedl

• What is shown in the cascade transformer arrangement is the basic principle

involved. The actual arrangement could be different for practical reasons.

• In the cascade arrangement shown, each transformer needs only to be insulated for

100 kV, and hence the transformer can be relatively small. If a 300 kV transformer

had to be used instead, the size would be massive. High voltage transformers for

testing purposes are designed purposely to have a poor regulation.

• This is to ensure that when the secondary of the transformer is short circuited (as

will commonly happen in flash-over tests of insulation), the current would not

increase to too high a value and to reduce the cost. In practice, an additional series

resistance (commonly a water resistance) is also used in such cases to limit the

current and prevent possible damage to the transformer.

• What is shown in the cascade transformer arrangement is the basic principle

involved. The actual arrangement could be different for practical reasons.

Cascade arrangement of transformers

Page 55: Hv genration   transpformation - converson & distribution - revisedl

High D.C. Voltages

• Generation of high d.c. voltages is mainly required in research work in the areas of pure and applied physics.

• Needed in insulation test.

• Use rectifier circuit (diode) to convert a.c. to d.c.

• voltage. – vacuum rectifiers, semiconductor diodes

Page 56: Hv genration   transpformation - converson & distribution - revisedl

Impulse High Voltage • Impulse voltages (IVs) are required in hv tests to simulate the

stresses due to external and internal overvoltages, and also for fundamental investigations of the breakdown mechanisms.

• Usually generated by discharging hv capacitors through switching gaps onto a network of resistors and capacitors.

• In hv technology, a single, unipolar voltage is termed an impulse voltage.

• Rectangular and wedge-shaped IVs are normally used for basic experiments while for testing purposes, double exponential IVs are used.

• Standard test of impulse voltages can be represented as double exponential wave, and its mathematical equation is defined as follows;

V = Vo [exp(-αt) – exp(-βt)]

Where α and β are constants of microsecond values.

Page 57: Hv genration   transpformation - converson & distribution - revisedl

Controlled Rectification• The generated three power supply on a phase a.c. electrical ship

has a fixed voltage and frequency. This is generally at M0 V and 60 Hz but for high power demands it is likelv to be 6.6 kV and 60 Hz.

• Speed control for a propulsion motor requires variable voltage for a d.c. drive and variable frequency * voltage for an a.c. drive.

• The set bus-bar a.c. voltage must be converted by controlled rectification (a.c.--d.c.) ind/or controlled inversion (d. c. * a. c. )' to match the propulsion motor type.

• A basic rectifier uses semiconductor diodes which can only conduct current in the direction of anode (A) to cathode (K) and this is automatic when A is more positive than K.

• The diode turns-off automatically when its current falls to zero. Hence, in –a single-phase a.c. circuit a single diode will conduct only on every other half-cycle and this is called half-wave rectification.

Page 58: Hv genration   transpformation - converson & distribution - revisedl

Single-phase controlled rectification.

Page 59: Hv genration   transpformation - converson & distribution - revisedl

Controlled Rectification• In this circuit an inductor coil (choke) smooth the d.c. load current even

though the d.c. voltage is severely chopped by the thyristor switching action.

• An alternative to the choke coil is to use a capacitor across the rectifier output which smooths the d.c. voltage. Full wave controlled rectification from a three-phase a.c. supply is achieved in a bridge Circuit with six thyristors a shown

• Other single-phase circuits using a biased arrangement with two diodes and a centre-tapped transformer will create full-wave rectification Similarly, four diodes in a bridge formation will also produce a full-wave d.c. voltage output.

• An equivalent three phase bridge requires six diodes for full-wave operation. A diode, having only two terminals, cannot control the size of the d.c. output from the rectifier.

• For controlled rectification it is necessary to use a set of three-terminal devices such as thyristors (for high currents) or transistors (for low - medium currents).

Page 60: Hv genration   transpformation - converson & distribution - revisedl

Three-phase controlled rectifier bridge circuit.

Page 61: Hv genration   transpformation - converson & distribution - revisedl

Three-phase controlled rectifier bridge circuit.

• A basic a.c.-d.c. control circuit using a thyristor switch is shown in the next slide. Compared with a diode, a thyristor has an extra (control) terminal called the gate (G).

• The thyristor will only conduct when the anode is positive with respect to the cathode and a brief trigger voltage pulse is applied between gate and cathode (gate must be more positive than cathode).

• Gate voltage pulses are provided by separate electronic circuit and the pulse timing decides the switch-on point for the main (load) current. The load current is therefore rectified to d.c. (by diode action) and controlled by delayed switching.

• In this circuit an inductor coil (choke) smooth the d.c. load current even though the d.c. voltage is severely chopped by the thyristor switching action.

• An alternative to the choke coil is to use a capacitor across the rectifier output which smooths the d.c. voltage. Full wave controlled rectification from a three-phase a.c. supply is achieved in a bridge Circuit with six thyristors a shown

Page 62: Hv genration   transpformation - converson & distribution - revisedl

Three-phase controlled rectifier bridge circuit.• The equivalent maximum d.c. voltage output is taken to be about 600 V as

it has a six-pulse ripple effect due to the three-phase input waveform.

• Controlled inversion process - A d.c. voltage can be inverted (switched) repeatedly from positive to negative to form an alternating (u.c.) voltage by using a set of thyristor (or transistor) switches. A controlled three-phase thyristor bridge inverter is shown

• The inverter bridge circuit arrangement is exactly the same as that for the rectifier. Here, the d.c. voltage is sequentially switched onto the three output lines. The rate of switching determines the output frequency.

• For a.c. motor control, the line currents are directed into (and out of) the windings to produce a rotating stator flux wave which interacts with the rotor to produce torque.

• The processes of controlled rectification and inversion are used in converters that are designed to match the drive motor.

Page 63: Hv genration   transpformation - converson & distribution - revisedl

Three-phase inverter circuit and a.c. synchronous motor

Page 64: Hv genration   transpformation - converson & distribution - revisedl

Converter Types

The principal types of motor control converters are:

- >a.c.-d.c. (controlled rectifier for d.c. motors) . a.c.-d.c.-a.c. (PWM for induction motors)

- >a.c.- d.c.-a.c. (synchroconverter or synchronous motors) .

-> d.c.-a.c. (cycloconverter for synchronous motors)

These are examined below:

a.c.- d.c. converter

• This is a three phase a.c. controlled rectification circuit for a d.c. motor drive.

• Two converters of different power ratings are generally used for the separate control of the armature current and the field current which produces the magnetic flux .

• Some systems may have a fixed field current which means that the field supply only requires an uncontrolled diode bridge

Page 65: Hv genration   transpformation - converson & distribution - revisedl

Converter Types

• Shaft rotation can be achieved by reversing either the field current or the armature current direction.

• Ship applications for such a drive would include cable-laying, offshore drilling, diving and supply, ocean survey and submarines.

a.c.- d.c.-a.c. PWM converter

• This type of converter is used for induction motor drives and uses transistors as the switching devices.

• Unlike thyristors, a transistor can be turned on and off by a control signal and at a high switching rate (e.g. at 20 kHz in a PWM converter).

• The input rectifier stage is not controlled so is simpler and cheaper but the converter will not be ablg to allow power from the motor load to be regenerated back into the mains supply during a braking operation.

Page 66: Hv genration   transpformation - converson & distribution - revisedl

Controlled rectification converter and d.c. motor

Page 67: Hv genration   transpformation - converson & distribution - revisedl

PWM converter and a.c. induction motor

Page 68: Hv genration   transpformation - converson & distribution - revisedl

Converter Types

• From a 440 Y a.c. supply, the rectified d.c. (link) voltage will be smoothed by the capacitor to approximately 600 V.

• The d.c. voltage is chopped into variablewidth, but constant level, voltage pulses in the computer controlled inverter section using IGBTs (insulated gate bipolar transistors).

• This process is called pulse width modulation or PWM. By varying the pulse widths and polarity of the d.c. voltage it is possible to generate an averaged sinusoidal ac. output over a wide range of frequencies typically 0.5-120Hz.

• Due to the smoothing effect of the motor inductance, the motor currents appear to be nearly sinusoidal in shape.

• By sequentially directing the currents into the three stator windings, a reversible rotating magnetic field is produced with its speed set by the output frequency of the PWM converter.

Page 69: Hv genration   transpformation - converson & distribution - revisedl

Converter Types• Accurate control of shaft torque, acceleration time and resistive braking are

a few of the many operational parameters that can be programmed into the VSD,usually via a hand-held unit.

• The VSD can be closelv tuned to the connected motor drive to achieve optimum control and protection limits for the overall drive.

• Speed regulation against load changes is very good and can be made very precise by the addition of feedback from a shaft speed encoder.

• VSDs, being digitally controlled, can be easily networked to other computer devices e.g. programmable logic controllers (PLCs) for overall control of a complex process.

Page 70: Hv genration   transpformation - converson & distribution - revisedl

Converter Types

a.c.*d.c.+a.c. synchroconverter

• This type of convert is used for large a.c. synchronous motor drives (called a synchrodrive) and I is applied very successfully to marine electric propulsion.

• A synchroconverter has controlled rectifier and inverter stages which both rely on natural turn-off (line commutation) for the thyristors by the three phase a.c. voltages at either end of the converter.

• Between the rectification and inversion stages is a current-smoothing reactor coil forming the d.c. link.

• An operational similarity exists between a svnchrodrive and a d.c. motor drive. DC link synchroconverter and a dc motor drive.

Page 71: Hv genration   transpformation - converson & distribution - revisedl

Synchroconverter circuit.

Page 72: Hv genration   transpformation - converson & distribution - revisedl

Inverter current switching sequence

Page 73: Hv genration   transpformation - converson & distribution - revisedl

Converter Types

• This view considers the rectifier stage as a controlled d.c. supply and the inverter/synchronous motor combination as a d.c. motor. with the switching inverter acting as a static commutator.

• The combination of controlled rectifier and d.c. link is considered to be a current source for the inverter whose task is then to sequentially direct blocks of the current into the motor windings

• The size of the d.c. current is set by the controlled switching of the rectifier thyristors.

• Motor supply frequency (and hence its speed) is set by the rate of inverter switching.

• The six inverter thyristors provide six current pulses per cycle (known as a six-pulse converter)

Page 74: Hv genration   transpformation - converson & distribution - revisedl

Converter Types

• A simplified understanding of synchroconverter control is that the current source (controlled rectification stage) provides the required motor torque and the inverter stage controls the required speed.

• To provide the motor e.m.f. which is necessary for natural commutation of the inverter thyristors, the synchronous motor must have rotation and magnetic flux in its rotor poles.

• During normal running, the synchronous motor is operated with a power factor of about 0.9 leading (by field excitation control) to assist the line commutation of the inverter thyristors.

• The d.c. rotor field excitation is obtained from a separate controlled thvristor rectification circuit.

Page 75: Hv genration   transpformation - converson & distribution - revisedl

Converter Types

• As the supply (network) and machine bridges

are identical and are both connected to a three-

phase a.c. voltage source, there roles can be

switched into reverse.

• This is useful to allow the regeneration motor

power back into the mains power supply which

provides an electric braking torque during a

crash stop of the ship.

Page 76: Hv genration   transpformation - converson & distribution - revisedl

Cycloconverter circuit and output

voltage waveform.

Page 77: Hv genration   transpformation - converson & distribution - revisedl

Converter Typesa.c.- a.c. cycloconverter

• While a synchroconverter is able to provide an output frequency range typically up to twice that of the mains input (e.g. up to 120 Hz), a cycloconverter is restricted to a much lower range.

• This is limited to less than one thtird of the supply frequency (e.g. up to 20 Hz) which is due to the way in which this type of converter produces the a.c. output voltage waveform.

• Ship ropulsion shaft speeds are typically in the range of 0-145 rev/min which can easily be achieved by the low frequency output range of a cycloconverter to a multi-pole synchronous motor.

• Power regeneration from the motor back into the main power supply is available. A conventional three phase converter from a.c. to d.c. can be controlled so that the average output voltage can be increased and decreased from zero to maximum within a half-cycle period of he sinusoidal a.c. input.

Page 78: Hv genration   transpformation - converson & distribution - revisedl

Converter Types• By connecting two similar converters back-to-back in each line an a.c.

output frequency is obtained.

• The switching pattern for the thyristors varies over the frequency range which requires a complex computer program for converter control.

• The corresponding current waveform shape (not shown) will be more sinusoidal due to the smoothing effect of motor and line inductance.

• The output voltage has ripple content which gets as the output frequency it is this feature that limits useful frequency.

• There is no connection between the three motor windings because the line converters have to be isolated from each other to operate correctly to obtain line commutation (natural) switching of the thvristors.

• The converters may be directly supplied from the HV line but it is more usual to interpose step-down transformers. This reduces the motor voltage and its required insulation level while also providing additional line impedance to limit the size of prospective fault current and harmonic voltage distortion at the main supply bus-bar.

Page 79: Hv genration   transpformation - converson & distribution - revisedl

Twin Shaft EL Propulsion

Page 80: Hv genration   transpformation - converson & distribution - revisedl

FPSO Electrical system Layout

Page 81: Hv genration   transpformation - converson & distribution - revisedl

Shuttle Tanker Electrical System Layout

Page 82: Hv genration   transpformation - converson & distribution - revisedl

Shuttle Tanker Electrical Line Diagram

Page 83: Hv genration   transpformation - converson & distribution - revisedl

Drill Ship Electrical System Layout

Page 84: Hv genration   transpformation - converson & distribution - revisedl

The future

• Propulsion of ships by help of standard diesel engines usually gives a non-optimal utilization of the energy.

• Today an increased use of diesel electrical propulsion of ships can be seen. New power electronics and electrical machines will be developed for propulsion and thrusters, as well as other application on board.

• Knowledge has to be developed about how such large motor drives will influence the autonomous power systems on-board.

• Even development of new integrated electrical systems for replacement of hydraulic systems (top-side as well as sub-sea) are becoming areas of need.

Page 85: Hv genration   transpformation - converson & distribution - revisedl

Typical system of all electrical ship

• Generator sets complete with prime movers and engine controls

• HV/LV Switchboards, distribution systems and group starter boards

• Propulsion and thruster motors complete with power electronic variable speed drives

• Power conversion equipment

• Shaft braking

• Power factor correction and harmonic filters

• (as necessary)

• Power management

• Machinery control and surveillance

• Dynamic positioning and joystick control

• Machinery control room and bridge consoles

• Setting to work and commissioning

• Operator training

Page 86: Hv genration   transpformation - converson & distribution - revisedl

Future electrical ship

• Future HV ships systems at sea may require voltages up to 13.8 kV to minimize fault levels

• It is therefore essential that all Marine Engineering personnel are trained in safe working practices for these voltages.

• The Electrical officers of the near future must be fully trained to carry out maintenance and defect rectification on Medium Voltage (MV) systems.

• This will mean a considerable increase in the electrical content of all training.

• Training will also need to be given to non-technical personnel to ensure everybody is aware of the dangers of these higher voltages.

Page 87: Hv genration   transpformation - converson & distribution - revisedl

Available systems