313874EEN
Repair - Parts
VRM™
Hydraulic, Plural-component, Variable-Ratio Proportioner. For pouring and dispensingsealants and adhesives. For professional use only.
Not approved for use in European explosive atmosphere locations.
See page 4 for model information, including maximumworking pressure and approvals.
Important Safety InstructionsRead all warnings and instructions in thismanual. Save these instructions.
ti17663a
2 313874E
ContentsRelated Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Important Two-Component Material Information . 8
Isocyanate Conditions . . . . . . . . . . . . . . . . . . . . . 8Material Self-ignition . . . . . . . . . . . . . . . . . . . . . . 8Keep Components A (Red) and B (Blue) Separate 8Moisture Sensitivity of Isocyanates . . . . . . . . . . . 8Changing Materials . . . . . . . . . . . . . . . . . . . . . . . 9
A (Red) and B (Blue) Components . . . . . . . . . . . . . 9Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Linear Position Sensor Replacement . . . . . . . . 10Hydraulic Driver Removal . . . . . . . . . . . . . . . . . 11Dura-Flo Lower Removal . . . . . . . . . . . . . . . . . 12Hydraulic Power Pack Repair . . . . . . . . . . . . . . 14
Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Systems, 24F391, 24F872, 24F873 . . . . . . . . . 22Machine Base, 24C168 . . . . . . . . . . . . . . . . . . . 23Power Pack Module . . . . . . . . . . . . . . . . . . . . . 27Power Pack Module Sub-Assemblies . . . . . . . . 28Vertical Driver Pumps . . . . . . . . . . . . . . . . . . . . 32Hydraulic Vertical Actuator . . . . . . . . . . . . . . . . 34Electrical Panels . . . . . . . . . . . . . . . . . . . . . . . . 35Power Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Fluid Control Panel . . . . . . . . . . . . . . . . . . . . . . 37Applicator Assembly . . . . . . . . . . . . . . . . . . . . . 38Mixer Manifold, 24F668 . . . . . . . . . . . . . . . . . . . 40Mixer Assembly, 24H027 . . . . . . . . . . . . . . . . . 42Floor Mounted Support . . . . . . . . . . . . . . . . . . . 43Hoses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Logic Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . 45230V 3 Phase Power Distribution Box . . . . . . . 45400V 3 Phase Power Distribution Box . . . . . . . 46B (Blue) Hydraulic Power Pack . . . . . . . . . . . . 47A (Red) Hydraulic Power Pack . . . . . . . . . . . . . 48Main Enclosure . . . . . . . . . . . . . . . . . . . . . . . . 49B (Blue) Hydraulic Power Pack and Dispense Head
Pneumatics . . . . . . . . . . . . . . . . . . . . . . . . . 50Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51Graco Standard Warranty . . . . . . . . . . . . . . . . . . . 52Graco Information . . . . . . . . . . . . . . . . . . . . . . . . . 52
Related Manuals
313874E 3
Related ManualsManuals are available at www.graco.com.
Component manuals in U.S. English:
System Manuals
313873 VRM Setup - Operation
Power Distribution Box Manual
3A0239 Power Distribution Boxes Instruc-tions-Parts
Pumpline Manuals
3A0022 U-Cup Dura-Flo™ Lowers
3A0021 Vertical Hydraulic DriverRepair-Parts
Feed System Manuals
3A1159 VRM Feed Systems
Valve Manuals
310550 1/2 in. NPT Fluid Port Ball SeatApplicator
310551 3/4 in. NPT Fluid Port Ball SeatApplicator
3A1792 DV Series Dispense Valves
Models
4 313874E
Models
* Full load amps with all devices operating at maximum capabilities. Fuse requirements at various flow rates andmix chamber sizes may be less.
** Values are dependent on installed pump size. Values shown are for largest available pump size.
◆ Flow rate is independent of frequency 50/60 Hz.
‡ If a motor control module is replaced, see Adjust Motor Control Module Selector Switch on page 16 to set themachine to the proper maximum fluid working pressure.
System approved
Full LoadPeakAmpsPer Phase*
Voltage(phase)
SystemWatts†
Max FlowRate◆**lb/min (kg/min)
ApproximateOutput perCycle (A+B)**gal. (liter)
HydraulicPressureRatio**
Maximum FluidWorking Pressure ‡psi (MPa, bar)
24F872 60 A 230 (3)
24,000 66 (30) 1.0 (3.8) 1.63 2000 (14, 138)24F391 55 A 400 (3)
24F873 ✔ 55 A 400 (3)
Warnings
313874E 5
WarningsThe following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer backto these warnings. Additional, product-specific warnings may be found throughout the body of this manual whereapplicable.
WARNING
ELECTRIC SHOCK HAZARDThis equipment must be grounded. Improper grounding, setup, or usage of the system can cause elec-tric shock.
• Turn off and disconnect power at main switch before disconnecting any cables and before servicingequipment.
• Connect only to grounded power source.
• All electrical wiring must be done by a qualified electrician and comply with all local codes and reg-ulations.
TOXIC FLUID OR FUMES HAZARDToxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, orswallowed.
• Read MSDSs to know the specific hazards of the fluids you are using.
• Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.
• Always wear chemically impermeable gloves when spraying, dispensing, or cleaning equipment.
PERSONAL PROTECTIVE EQUIPMENTYou must wear appropriate protective equipment when operating, servicing, or when in the operatingarea of the equipment to help protect you from serious injury, including eye injury, hearing loss, inhala-tion of toxic fumes, and burns. This equipment includes but is not limited to:
• Protective eyewear, and hearing protection.
• Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer.
+
SKIN INJECTION HAZARDHigh-pressure fluid from dispensing device, hose leaks, or ruptured components will pierce skin. Thismay look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgicaltreatment.
• Do not point dispensing device at anyone or at any part of the body.
• Do not put your hand over the fluid outlet.
• Do not stop or deflect leaks with your hand, body, glove, or rag.
• Follow the Pressure Relief Procedure when you stop dispensing and before cleaning, checking,or servicing equipment.
• Tighten all fluid connections before operating the equipment.
• Check hoses and couplings daily. Replace worn or damaged parts immediately.
Warnings
6 313874E
FIRE AND EXPLOSION HAZARDFlammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help preventfire and explosion:
• Use equipment only in well ventilated area.
• Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plasticdrop cloths (potential static arc).
• Keep work area free of debris, including solvent, rags and gasoline.
• Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumesare present.
• Ground all equipment in the work area. See Grounding instructions.
• Use only grounded hoses.
• Hold gun firmly to side of grounded pail when triggering into pail.
• If there is static sparking or you feel a shock, stop operation immediately. Do not use equipmentuntil you identify and correct the problem.
• Keep a working fire extinguisher in the work area.
EQUIPMENT MISUSE HAZARDMisuse can cause death or serious injury.
• Do not operate the unit when fatigued or under the influence of drugs or alcohol.
• Do not exceed the maximum working pressure or temperature rating of the lowest rated systemcomponent. See Technical Data in all equipment manuals.
• Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in allequipment manuals. Read fluid and solvent manufacturer’s warnings. For complete informationabout your material, request MSDS from distributor or retailer.
• Do not leave the work area while equipment is energized or under pressure. Turn off all equipmentand follow the Pressure Relief Procedure when equipment is not in use.
• Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manu-facturer’s replacement parts only.
• Do not alter or modify equipment.
• Use equipment only for its intended purpose. Call your distributor for information.
• Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
• Do not kink or over bend hoses or use hoses to pull equipment.
• Keep children and animals away from work area.
• Comply with all applicable safety regulations.
WARNING
Warnings
313874E 7
MOVING PARTS HAZARDMoving parts can pinch, cut or amputate fingers and other body parts.
• Keep clear of moving parts.
• Do not operate equipment with protective guards or covers removed.
• Pressurized equipment can start without warning. Before checking, moving, or servicing equip-ment, follow the Pressure Relief Procedure and disconnect all power sources.
BURN HAZARDEquipment surfaces and fluid that’s heated can become very hot during operation. To avoid severeburns:
• Do not touch hot fluid or equipment.
WARNING
Important Two-Component Material Information
8 313874E
Important Two-Component Material Information
Isocyanate Conditions
Material Self-ignition
Keep Components A (Red) andB (Blue) Separate
Moisture Sensitivity ofIsocyanatesIsocyanates (ISO) are catalysts used in two componentfoam and polyurea coatings. ISO will react with moisture(such as humidity) to form small, hard, abrasive crystals,which become suspended in the fluid. Eventually a filmwill form on the surface and the ISO will begin to gel,increasing in viscosity. If used, this partially cured ISOwill reduce performance and the life of all wetted parts.
NOTE: The amount of film formation and rate of crystal-lization varies depending on the blend of ISO, thehumidity, and the temperature.
To prevent exposing ISO to moisture:
• Always use a sealed container with a desiccantdryer in the vent, or a nitrogen atmosphere. Neverstore ISO in an open container.
• Keep the pump wet cups filled with IsoGuard
Select®, part 24F516. The lubricant creates a bar-rier between the ISO and the atmosphere.
• Use moisture-proof hoses specifically designed forISO, such as those supplied with your system.
• Never use reclaimed solvents, which may containmoisture. Always keep solvent containers closedwhen not in use.
• Never use solvent on one side if it has been contam-inated from the other side.
• Always lubricate threaded parts with ISO pump oilor grease when reassembling.
Spraying or dispensing materials containing isocya-nates creates potentially harmful mists, vapors, andatomized particulates.
Read material manufacturer’s warnings and materialMSDS to know specific hazards and precautionsrelated to isocyanates.
Prevent inhalation of isocyanate mists, vapors, andatomized particulates by providing sufficient ventila-tion in the work area. If sufficient ventilation is notavailable, a supplied-air respirator is required foreveryone in the work area.
To prevent contact with isocyanates, appropriate per-sonal protective equipment, including chemicallyimpermeable gloves, boots, aprons, and goggles, isalso required for everyone in the work area.
Some materials may become self-igniting if appliedtoo thickly. Read material manufacturer’s warningsand material MSDS.
Cross-contamination can result in cured material influid lines which could cause serious injury or dam-age equipment. To prevent cross-contamination ofthe equipment’s wetted parts, never interchangecomponent A (Red) and component B (Blue) parts.
A (Red) and B (Blue) Components
313874E 9
Changing Materials• When changing materials, flush the equipment mul-
tiple times to ensure it is thoroughly clean.
• Always clean the fluid inlet strainers after flushing.
• Check with your material manufacturer for chemicalcompatibility.
• Most materials use ISO on the A (Red) side, butsome use ISO on the B (Blue) side. See the follow-ing section.
A (Red) and B (Blue) ComponentsIMPORTANT!
Material suppliers can vary in how they refer to pluralcomponent materials.
Be aware that when standing in front of the manifold onproportioner:
• Component A (Red) is on the left side.• Component B (Blue) is on the right side.
For all machines:
• The A (Red) side is intended for ISO, hardeners,and catalysts.
• The B (Blue) side is intended for polyols, resins, andbases.
NOTE: For machines with material volume ratios otherthan 1:1, the higher volume side is typically the B (Blue)side.
Repair
10 313874E
Repair
Linear Position Sensor Replacement
NOTE: See FIG. 1 for part references.
1. Perform Shutdown procedure. See operation man-ual for procedure.
2. Remove pumpline shield.
3. Insert a large allen wrench through the center of thelift ring (717) then twist to loosen. Remove lift ring.
4. Disconnect linear position sensor cable. Route thecable through the hole in the plate (713) directlyabove the linear position sensor (718).
5. Use a 1-1/4 in. wrench to loosen the linear positionsensor. Remove the linear position sensor.
6. Carefully insert the new linear position sensorthrough the hole in the plate (713) and into the verti-cal hydraulic driver. Use a 1-1/4 in. wrench to gentlytighten.
FIG. 1
702
706
701
704
707
708
705
714
715
710
711
712
718
713
716
1
Torque to 100 ft-lb (135 N•m).
Torque to 350 in-lb (39.5 N•m).
Apply a light coating of lubricant to seals andsurfaces specified.
Torque to 50-60 ft-lb (68-81 N•m).
Apply adhesive to surfaces specified.
Torque to 10-12 in-lb (1.1-1.4 N•m).
Apply thread sealant to threads.
Torque to 30-36 ft-lb (41-49 N•m).
Orient ref 701 with date code on castingopposite of 0.25 diameter hole as shown. Ref704 to be on opposite side of 0.25 diameterhole as shown.
1
2
3
4
5
6
7
8
9
9
3
6
5
4
4
4
ti17670a
722, 723
708
3
2
9
Repair
313874E 11
Hydraulic Driver Removal
NOTE: This procedure details how to remove thehydraulic driver. Hydraulic driver rebuild information is inthe hydraulic driver manual.
NOTE: See FIG. 1 and FIG. 2 for part references.
1. Perform Shutdown and Pressure Relief Proce-dure procedures. See operation manual for proce-dures.
2. Remove the pump shield.
3. Remove three screws (716). Remove topplate (713).
4. Remove three tie rods (712). Remove plate (711)with linear position sensor (718).
5. Remove three tie rods (710).
6. Loosen the coupling nut (603) to disconnect theactuator and pump rods.
7. Remove the drip fittings connected to the base ofthe vertical hydraulic actuator.
8. Remove four screws (705) connecting hydraulicdriver to vertical actuator housing (704).
9. Remove three screws (706) that connect the bottomplate (702) to the rest of the hydraulic driver.
10. Remove the hydraulic driver (701).
11. See hydraulic driver manual for rebuild information.
NOTE: Install hydraulic driver in reverse order. Seenotes in the applicable parts illustrations for torque andother specifications.
FIG. 2
601 606 605 603602
607608
621618619620622
613
604
Isometric ViewTorque 50-60 ft-lb (68-81 N•m).
Torque 145-155 ft-lb (196-210 N•m).
Apply thread lubricant.
Apply thread sealant.
1
2
3
4
1
324 1
3 2
_1c
ti17669a
6043
623
Repair
12 313874E
Dura-Flo Lower Removal
NOTE: This procedure details how to remove theDura-Flo Lower. Rebuild information is in the Dura-FloLower manual.
See FIG. 3 for part references.
1. Perform Shutdown and Pressure Relief Proce-dure procedures. See operation manual for proce-dures.
2. Loosen the coupling nut (603) to disconnect thehydraulic vertical actuator and pump rods.
3. Use a large adjustable wrench to remove the largeinlet feed fittings at the base of the Dura-Flo Lowers.
4. Remove three screws (608).
5. Remove Dura-Flo Lower.
6. See Dura-Flo Lower manual for rebuild information.
NOTE: Install Dura-Flow Lower in reverse order. Seenotes in the applicable parts illustrations for torque andother specifications.
FIG. 3
601 606 605 603602
607608
621618619620622
613
604
Isometric ViewTorque 50-60 ft-lb (68-81 N•m).
Torque 145-155 ft-lb (196-210 N•m).
Apply thread lubricant.
Apply thread sealant.
1
2
3
4
1
324 1
3 2
_1c
ti17669a
6043
623
Repair
313874E 13
Repair
14 313874E
Hydraulic Power Pack Repair
FIG. 4: Hydraulic DC Power Pack
420
425
423
411
410
408
424
413
412
409
414
405
406
419
417
418
446
434435
415
416
404
429
402
421,
407
401
426438
437
428421, 422
444
430433432431445
Assemble coupler to specified dimensionsprior to mounting assembly to housing.
Torque to 40 ft-lb (54 N•m).
Torque to 35 ft-lb (47 N•m).
Torque to 20 ft-lb (27 N•m).
Torque to 15 ft-lb (20 N•m).
Torque to 10 ft-lb (14 N•m).
Torque to 58 in-lb (6.5 N•m).
Torque to 34 in-lb (3.8 N•m).
Torque 1/4 turn past hand-tight.
Apply PTFE tape on installation end only.
Apply sealant to threads.
Apply light coating of lubricant to seals.
Fill reservoir with hydraulic fluid.
Orient with airflow arrow pointing towardmounting bracket.
Prior to installing Ref. 428 into Ref. 426,install Ref. 429 into Ref. 428 and adjusthead 1/8 in. from surface.
Align fan plug as shown.
Apply thermal lubricant to contact side.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
24
26
9
11
212
311
5
10
12
2122
12
3 11
10
8 11 26
10
212
10
212 4 11427
5 11
913
611
71114 15
11
6
11
8
.45 +.00-.02
402 1
.30 +.01-.00
1406 24431
_1j
448, 449
436
403
Repair
313874E 15
Remove Hydraulic Power Pack Shroud
1. Remove four screws from base of shroud.
2. Lift shroud off of Hydraulic Power Pack.
Install Hydraulic Power Pack Shroud
1. Place shroud on top of Hydraulic Power Pack.
2. Install four screws securing shroud to hydraulic tank.
Replace Hydraulic Filter
Filter is located at right rear of hydraulic power pack.See FIG. 4 on page 14.
1. Perform Shutdown procedure. See operation man-ual for procedure.
2. Use compressed air to remove any loose debrisaround the hydraulic filter.
3. Remove new filter from wrapping.
4. Apply a light coat of hydraulic fluid to the o-ring onthe face of the hydraulic filter.
5. Being careful not to allow any debris into thehydraulic tank remove old filter from tank thenquickly install new filter.
Replace Fan
See FIG. 4 on page 14.
1. Perform Shutdown procedure. See operation man-ual for procedure.
2. Remove Hydraulic Power Pack Shroud, see pro-cedure on this page.
3. Remove four screws (432) connecting fan to mount-ing plate.
4. Remove fan and install new fan.
5. Install four screws (432) connecting fan to Motorand Motor Control Module.
6. Install Hydraulic Power Pack Shroud, see proce-dure on this page.
Remove Motor Control Module
See FIG. 4 on page 14.
1. Perform Shutdown procedure. See operation man-ual for procedure.
2. Remove Hydraulic Power Pack Shroud, see pro-cedure on this page.
3. Remove four screws (432) connecting fan to Motorand Motor Control Module. Remove fan and mount-ing plate.
4. Note the location of each Motor Control Modulecable then remove all electrical cables on the leftand right sides of the Motor Control Module.
5. Remove six screws (429) securing Motor ControlModule in place.
6. Slowly and carefully slide the Motor Control Moduleup until the cable on the bottom of the Motor ControlModule can be accessed and removed. Disconnectthe cable.
7. Slide the Motor Control Module up and remove.
NOTICE
Do not over-torque any item that threads into thehydraulic tank. This will strip the threads andrequire tank replacement.
NOTICE
If any debris falls into the hydraulic tank, the debrismust be removed or machine damage will result.
Repair
16 313874E
Adjust Motor Control Module SelectorSwitch
The Motor Control Module uses an 8-position selectorswitch (S) to set system maximum working pressure.See FIG. 5.
The system must be configured to have a maximumworking pressure of 2000 psi (13.8 MPa, 138 bar). Setthe selector switch according to the following table.
The selector switch position will be properly set at thefactory for new systems. When a motor control moduleis replaced, the selector switch must be set to the cor-rect setting by the user prior to initial startup.
To set the Motor Control Module selector switch:
1. Turn machine power off.
2. Remove the access cover (D). See FIG. 5.
3. Set the selector switch (S).
4. Install access cover (D).
Install Motor Control Module
This procedure starts assuming that the old Motor Con-trol Module is removed from the machine. See RemoveMotor Control Module procedure, see page 15.
See FIG. 4 on page 14.
1. Perform Adjust Motor Control Module SelectorSwitch procedure on page 16.
2. Slide the Motor Control Module into the slot.
3. Attach the cable on the bottom of the Motor ControlModule.
4. Install the six screws (429) securing Motor ControlModule in place.
5. Install electrical cables on left and right sides of theMotor Control Module.
6. Install four screws (432) connecting fan to Motorand Motor Control Module. Install fan and mountingplate.
7. Install Hydraulic Power Pack Shroud, see proce-dure on page 15.
NOTICE
If the Motor Control Module is replaced, the selec-tor switch must be set prior to initial startup of theMotor Control Module or damage may occur.
MCM Switch Position
B (Blue) 1
A (Red) 2
• Do not install components rated to less than themaximum working pressure. Doing so may lead tooverpressurization and ruptured components.
• High-pressure fluid from ruptured components willpierce skin. This may look like just a cut, but it is aserious injury that can result in amputation. Getimmediate surgical treatment.
FIG. 5
NOTICE
Motor Control Module selector switch position mustbe set prior to startup of Motor Control Module ordamage may occur.
S
257396_3b9905_04b
D
Repair
313874E 17
Remove Hydraulic Power Pack
This procedure removes the hydraulic power pack fromthe machine as a single unit to enable further disassem-bly. User must purchase three 5/16-18 eye-bolts capableof holding 300 lb to perform this procedure.
See FIG. 4 on page 14.
1. Perform Shutdown procedure. See operation man-ual for procedure.
2. Perform Remove Hydraulic Power Pack Shroud,see procedure on page 15.
3. Perform Remove Motor Control Module proce-dure, see page 15.
4. Remove four screws (705) to disconnect hydraulicvertical actuator from hydraulic power pack. SeeFIG. 1 on page 10.
5. Disconnect heat exchanger inlet hose and fittingfrom elbow fitting (417). Disconnect heat exchangeroutlet hose and fitting from elbow fitting (425).
6. Remove the two bolts (446) from the fluidhousing (403) and replace each with a strong5/16-18 thread eye-bolt. Install a third strong5/16-18 eye-bolt as indicated. See FIG. 6. See FIG. 4on page 14 for full hydraulic power pack view.
7. Run a rope through the three eye-bolts and betweenthe motor and the Motor Control Module. Secure toa hydraulic lift.
8. Remove the four bolts (304) and washers (303)securing the tank to the electrical enclosure. SeePower Pack Module on page 27.
9. Lift the hydraulic power pack and place on a sturdylocation capable of supporting up to 300 lb (136 kg).
The hydraulic power pack weighs up to 300 lb. Toavoid serious injury due the hydraulic power pack fall-ing, secure the hydraulic lift when raising the hydraulicpower pack.
NOTICE
If any debris falls into the hydraulic tank, the debrismust be removed or machine damage will result.
FIG. 6
403 446
446
Install third eye-bolt here_1j1
Repair
18 313874E
Install Hydraulic Power Pack
This procedure assumes the Hydraulic Power Pack hasbeen removed from the machine and is assembledexcept for the Motor Control Module.
See FIG. 4 on page 14.
1. Run a rope through the three eye-bolts and betweenthe Motor and the Motor Control Module. Secure toa hydraulic lift.
2. Lift the Hydraulic Power Pack and place onto theelectronic enclosure.
3. Align the holes with the tank then install finger-tightthe four bolts (304) and washers (303) securing thetank to the electrical enclosure. Torque to 10 ft-lb(14 N•m).
4. Remove rope and lift.
5. Remove eye-bolts. Install original bolts (446) intofluid housing (403). See FIG. 6.
6. Perform Install Motor Control Module procedure,see page 16.
7. Connect heat exchanger inlet hose and fitting toelbow fitting (417). Connect heat exchanger outlethose and fitting to elbow fitting located on rear rightface of tank. See Power Pack Module on page 27.
8. Install four screws (705) to connect hydraulic verti-cal actuator to hydraulic power pack. See FIG. 1 onpage 10.
Replace Tank Gasket, Tank
See FIG. 4 on page 14.
1. Perform Remove Hydraulic Power Pack proce-dure, see page 17.
2. Remove hex head cap screws (422) securinghydraulic housing (403) to tank (420). Carefullyremove motor (401) and hydraulic housing assem-bly from tank.
3. Remove tank gasket. If tank is damaged, replacetank.
4. Install thrust washers (421) onto hex head capscrews (422). Apply pipe sealant to threads ofscrews. Align tank gasket (419), hydraulic housing,and tank (420) then install screws. Torque to15 ft-lb (20 N•m).
5. Perform Install Hydraulic Power Pack procedure,see page 18.
Remove Motor
See FIG. 4 on page 14.
1. Perform Remove Hydraulic Power Pack proce-dure, see page 17.
2. Remove four hex head cap screws (422) securinghydraulic housing (403) and motor (401) totank (420). Carefully remove motor and hydraulichousing assembly from tank.
3. Remove four hex head cap screws (427) connectingmounting bracket (426) to motor.
NOTICE
If any debris falls into the hydraulic tank, the debrismust be removed or machine damage will result.
NOTICE
Do not over-torque any item that threads into thehydraulic tank. This will strip the threads andrequire tank replacement.
NOTICE
Do not over-torque any item that threads into thehydraulic tank. This will strip the threads andrequire tank replacement.
Repair
313874E 19
4. Remove four socket head cap screws (404) secur-ing motor to hydraulic housing. Carefully removemotor from hydraulic housing.
5. Loosen set screw for motor coupler (402) thenremove motor coupler.
Install Motor
See FIG. 4 on page 14.
1. Use four hex head cap screws (427) and thrustwashers (421) to install Motor Control Modulemounting bracket (426) onto motor (401).
2. Install motor coupler (402) onto motor (401). Cou-pler must be 0.65-0.67 in. from the face of themotor. Torque motor coupler set screw to 15 ft-lb(20 N•m).
3. Install spider coupler (407) into motor coupler.
4. Use four socket head cap screws (404) to attachhydraulic housing (403) to motor. Be sure to alignteeth of gear coupler with the teeth of the motor cou-pler. Apply pipe sealant to threads of screws. Torqueto 35 ft lb (47 N•m).
5. Install thrust washers (421) onto hex head capscrews (422). Apply pipe sealant to threads ofscrews. Align tank gasket (419), hydraulic housing,and tank (420) then install screws. Torque to 15 ft-lb(20 N•m).
6. Perform Install Hydraulic Power Pack procedure,see page 18.
Remove Hydraulic Gear Pump
See FIG. 4 on page 14.
1. Perform Remove Hydraulic Power Pack proce-dure, see page 17.
2. Remove hex head cap screws (422) securinghydraulic housing (403) to tank. Carefully removemotor (401) and hydraulic housing assembly.
3. Remove tube (411).
4. Remove elbow fittings (410, 412) from gearpump (405).
5. Remove two hex head cap screws (408) securinggear pump to hydraulic housing.
6. Remove spider coupler (407).
7. Loosen set screw for gear coupler (406) thenremove gear coupler from gear pump.
Install Hydraulic Gear Pump
See FIG. 4 on page 14.
1. Install gear coupler (406) onto gear pump (405).Coupler must be 0.12 to 0.13 in. from the face of thegear pump. Torque gear coupler set screw to 15 ft-lb(20 N•m).
2. Install spider coupler (407) into gear coupler.
3. Use two hex head cap screws (408) to attach gearpump to hydraulic housing. Be sure to align teeth ofgear coupler with the teeth of the motor coupler.Torque screws to 35 ft-lb (47 N•m).
4. Apply a light coat of lubricant to seals of elbowfittings (410, 412). Install elbow fittings into gearpump. See FIG. 4 on page 14. for fitting alignment.Torque both fittings to 40 ft-lb (54 N•m).
NOTICE
Do not over-torque any item that threads into thehydraulic tank. This will strip the threads andrequire tank replacement.
Repair
20 313874E
5. Apply a light coating of lubricant to seals oftube (411). Install tube (411) onto elbow fitting (410)and straight fitting (409). Hand-tighten then usewrench to tighten 90 degrees further.
6. Install thrust washers (421) onto hex head capscrews (422). Apply pipe sealant to threads ofscrews. Align tank gasket (419), hydraulic housing,and tank (420) then install screws. Torque to 15 ft-lb(20 N•m).
7. Perform Install Hydraulic Power Pack procedure,see page 18.
NOTICE
Do not over-torque any item that threads into thehydraulic tank. This will strip the threads andrequire tank replacement.
Repair
313874E 21
Parts
22 313874E
Parts
Systems, 24F391, 24F872, 24F873
--- Not for sale.
101
103104
108
106
107
109
ti17663a
105
102
Ref Part Description
Quantity24F872,
SYSTEM, 230v24F391,
SYSTEM, 400v24F873,
SYSTEM, 400v CE101 24C168 BASE, var ratio, bare 1 1 1102 --- MODULE, power distribution box, 400v,
3-phase, base, non-CE1
--- MODULE, power distribution box, 230v,3-phase
1
--- MODULE, power distribution box, 400v,3-phase
1
103 --- PUMP, vertical driver, 580SS 1 1 1104 --- PUMP, vertical driver, 430SS 1 1 1105 --- MODULE, electric, panels 1 1 1106 --- MODULE, flow meter 1 1 1107 --- APPLICATOR, mast mount 1 1 1108 24F726 HOSE, 3/4 ID, 180 in. long, female/male 1 1 1109 24F951 HOSE, 1/4 ID, 180 in. long, female/male 1 1 1
Parts
313874E 23
Machine Base, 24C168
FIG. 7: Machine Base, 1 of 2
Torque to 150 in-lb(16.9 N•m).
Torque to 300 in-lb(33.9 N•m).
Torque to 62 in-lb(7.0 N•m).
Connect ref 252 toport 10 on eachmotor controlmodule.
Apply threadsealant to pipethreads.
Apply thin coatingof lubricant toseals.
Connection pointfor footswitch, ref260.
Route ref 250through wirewayand connect to B(Blue) high volumeMCM port 2B.
Route power cableof ref 263 throughwire loops andsecure with wireties on heat panel.Routecommunicationcables throughwire loops.
2
3
4
5
7
8
10
11 14
ti17668a
202
248,
233
232
264,248
4
263
210, 262211
212, 213, 248214, 262
269, 262
215
216
250 11
220
14
268
267
265
214, 262
266
204
244
229
272
270
271
248, 2172
238
235240
234
237
236
225
239
Shown forreference only 83
Parts
24 313874E
FIG. 8: Machine Base, 2 of 2
ti17765a
2204
255
252 5
247
261
201
203
259, 254
253
251
258
230
219
218
222228
227226
224225
223
2042
255
241
231
10
253
220
ti17767a
Parts
313874E 25
--- Not for sale.
† To install or update software, purchase softwareupgrade token 16G365.
▲ Replacement Danger and Warning labels, tags andcards are available at no cost.
Ref Part Description Qty201 --- FRAME, pump, dual, vertical 1202 --- MODULE, power pack, enclosure 2203 110996 NUT, hex, flange head 4204 111800 SCREW, cap, hex head 14210 103413 PACKING, o-ring 4211 --- PLATE, hydraulic adapter 2212 111803 SCREW, cap, hex head 8213 100731 WASHER 8214 121309 FITTING, adapter, SAE-ORB x JIC 6215 --- COVER, wireway 2216 100333 SCREW, cap, hex head 4217 110837 SCREW, flange, hex 8218 24E451 MODULE, GCA, ADM 1219 15V551 SHIELD, membrane, ADM 0.1220 121003 CABLE, can, female / female 3.0 m 1222 255235 BRACKET, mounting, assembly 1223 24E647 BRACKET, adm mounting 1224 --- RIVET, aluminum 2225 120060 CLIP, speed, tubular 10226 110755 WASHER, plain 1227 100016 WASHER, lock 1228 121253 KNOB, display adjustment 1229 24B855 COVER, assembly 2230 --- COVER, pump, front 1231 --- COVER, enclosure, slotted 2232 122970 FITTING, adapter, JIC(08) x SAE(08) 2233 123140 FITTING, cap, 1/2 JIC 2234 --- COVER, front, driver 2235 --- COVER, back, driver 2236 --- PLATE, name, valve cover 2237 123347 CLIP, tree, removable 12238 123942 FASTENER, screw, cap, hex head 4239 --- STRIP, polyurethane foam 6240▲ 15F674 LABEL, safety, motor 2241 24E896 CABLE, M8, 4-pin, male/female, 2 m 2243 16C779 LABEL, identification, electronics 1244▲ 15M511 LABEL, warning, English, Spanish,
French1
245 --- FLUID, hydraulic 18246 --- SEALANT, pipe 1247 --- PLUG, hole, 1.5 in. dia 2248 --- SEALANT, anaerobic 1250 124344 CABLE, GCA, M12-5pin,
male/female, 1.0 m1
251 16E779 LABEL, VRM, metering system 1252 124476 CABLE, M8, 4-pin, male/male, 3 m 1253 255468 KIT, accessory, light tower 1254 --- BUSHING, wire protector, 0.875 dia 1255 --- BUSHING, wire protector, snap-in 4256 24F516 FLUID, IGS™ 1
258 16G195 LABEL 1259 121581 HARNESS, I/O, M12 x M12 1261 124128 BUSHING, wire protector, snap-in 4262 --- LUBRICANT, grease 1263 123313 VALVE, directional, hydraulic 2264 123366 SCREW, socket head cap, 10-24 x
1.1258
265 16H782 TUBE, hydraulic 1266 16H783 TUBE, hydraulic 1267 16H785 TUBE, hydraulic 1268 16H784 TUBE, hydraulic 1269 121312 FITTING, elbow, SAE x JIC 2270 16G251 HOUSING, filter 2271 16G252 FILTER, air 2272 15U075 SCREW, cap, 8-32 x 0.37 8273† --- SOFTWARE 1
Ref Part Description Qty
Parts
26 313874E
Parts
313874E 27
Power Pack Module
--- Not for sale.
▲ Replacement Danger and Warning labels, tags andcards are available at no cost.
308
309
306
305
301
303
304307
310
Torque to 10 ft-lb (14 N•m).
Apply sealant to threads.
1
2
21
_1d _2d
Ref Part Description Qty301 --- ENCLOSURE, frame 1
302 --- MODULE, hydraulic power 1
303 U90205 WASHER, flat, 3/8, 0.41 x 1.25 x 0.13 4
304 802277 SCREW, machine 4
305 --- COVER, enclosure, heat exchanger 1
306 111800 SCREW, cap, button head 2
307 15Y935 TUBE, heat exchanger, outlet 1
308 24C621 HOSE, heat exchanger, inlet 1
309 123528 FITTING, elbow, swivel, 45, JIC08,female/male
1
310 24C518 CORD, fan, heat exchanger, MCM 2
311 --- SEALANT, anaerobic 1
312▲ 189930 LABEL, caution, electric shock (not shown) 1
313▲ 15H108 LABEL, pinch point (not shown) 1
Parts
28 313874E
Power Pack Module Sub-Assemblies
Hydraulic DC Power Pack Module
FIG. 9: Hydraulic DC Power Pack
420
425
423
411
410
408
424
413
412
409
414
405
406
419
417
418
446
434435
415
416
404
429
402
421,
407
401
426438
437
428421, 422
444
430433432431445
Assemble coupler to specified dimensionsprior to mounting assembly to housing.
Torque to 40 ft-lb (54 N•m).
Torque to 35 ft-lb (47 N•m).
Torque to 20 ft-lb (27 N•m).
Torque to 15 ft-lb (20 N•m).
Torque to 10 ft-lb (14 N•m).
Torque to 58 in-lb (6.5 N•m).
Torque to 34 in-lb (3.8 N•m).
Torque 1/4 turn past hand-tight.
Apply PTFE tape on installation end only.
Apply sealant to threads.
Apply light coating of lubricant to seals.
Fill reservoir with hydraulic fluid.
Orient with airflow arrow pointing towardmounting bracket.
Prior to installing Ref. 428 into Ref. 426,install Ref. 429 into Ref.428 and adjust head1/8 in. from surface.
Align fan plug as shown.
Apply thermal lubricant to contact side.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
24
26
9
11
212
311
5
10
12
2122
12
3 11
10
8 11 26
10
212
10
212 4 11427
5 11
913
611
71114 15
11
6
11
8
.45 +.00-.02
402 1
.30 +.01-.00
1406 24431
_1j
448, 449
436
403
Parts
313874E 29
--- Not for sale.
▲ Replacement Danger and Warning labels, tags and cards are available at no cost.
Ref Part Description Qty401 --- MOTOR, power connector, assembly 1
402 16A951 COUPLER, motor 1
403 --- HOUSING, machined, hydraulic 1
404 123338 SCREW, socket head cap, 3/8-16 x 2.75 4
405 --- PUMP, gear, hydraulic, H39 1
406 16A952 COUPLER, pump 1
407 16A953 COUPLER, spider 1
408 123942 SCREW, cap, hex head 2
409 15T939 FITTING, straight, JIC8 x SAE8 1
410 122520 FITTING, elbow, male, SAE x JIC 1
411 --- TUBE, pump to tube outlet 1
412 122606 FITTING, elbow, male, female 1
413 115597 NIPPLE 1
414 101353 FITTING, nipple, pipe 1
415 122527 VALVE, relief 1
416 100721 PLUG, pipe 1
417 121312 FITTING, elbow, SAE x JIC 1
418 101754 PLUG, pipe 1
419 --- GASKET, housing, to, tank 1
420 --- RESERVOIR, assembly, 8 gallon 1
421 101971 WASHER, thrust 4
422 111302 SCREW, cap, hex head 4
423 15J937 FILTER, oil, 18-23 psi bypass 1
424 116915 CAP, breather filler 1
425 121486 FITTING, elbow, male, 1/2 JIC x 1/2 NPT 1
426 15Y912 BRACKET, MCM mounting 1
427 100057 SCREW, cap hex head 4
428 257396 MODULE, motor control 1
429 101550 SCREW, cap 7
430 --- PLATE, mounting, fan 1
431 122301 FAN, 220V 1
432 112310 SCREW, cap 8
433 100644 SCREW, cap 2
434 123367 HARNESS, M8 x thermal switch, 4-pin 1
435 102410 SCREW, socket head cap 1
436 --- FLUID, hydraulic (gallon) 8
437 123303 HARNESS, M12 2
438 295709 SCREW, socket head 4
439 --- LUBRICANT, grease 1
440 --- SEALANT, pipe 1
441 --- SEALANT, pipe 1
443▲189285 LABEL, caution 1
444▲121208 LABEL, hot surface 1
445▲15H108 LABEL, pinch point 1
446 109468 SCREW, cap, hex head 2
447 --- LUBRICANT, thermal 1
448 123601 CLAMP, wire, harness, nylon, 3/4 5
449 103833 SCREW, mach 5
Parts
30 313874E
Heat Exchanger Assembly
--- Not for sale.
501 504506
502
507
505
Torque to 65 ft-lb (88 N•m).
Apply lubricant to o-rings beforeassembling.
Torque to 8 ft-lb (11 N•m).
Torque to 2.5 ft-lb (3.4 N•m).
Apply sealant to threads.
Orient fan with airflow arrow pointingtoward cover.
Align fan plug as shown.
1
2
3
4
5
6
7
7
505
4 5
3 5508
5031 2
_1f
_2f
Ref Part Description Qty501 --- COVER, enclosure, heat
exchanger1
502 --- GASKET, fan, mounting 1503 122300 EXCHANGER, heat, M-4 1504 122301 FAN, 220V 1505 122842 FITTING, elbow, SAE x JIC 2506 15U075 SCREW, cap, button head, 8-32
x 0.378
507 110755 WASHER, plain 4508 100022 SCREW, cap, hex head 4510 --- LUBRICANT, thread 1511 --- SEALANT, anaerobic 1
Parts
313874E 31
Parts
32 313874E
Vertical Driver Pumps
601 606 605 603602
607608
621618619620622
613
604
1
324 1
3 2
_1c
ti17669a
6043
623
Torque 50-60 ft-lb (68-81 N•m).
Torque 145-155 ft-lb (196-210 N•m).
Apply thread lubricant.
Apply thread sealant.
1
2
3
4
Isometric View
625626
624
627
628
629
Parts
313874E 33
--- Not for sale.
Ref Part Description
QuantityPUMP, vertical driver,
430SSPUMP, vertical driver,
580SS601 --- ACTUATOR, vertical, hydraulic 1 1602 L430S2 LOWER, u-cup, 430cc, enclosed 1602 L580S2 LOWER, u-cup, 580cc, enclosed 1603 184096 NUT, coupling 1 1604 184130 COLLAR, coupling 2 2605 15Y798 ADAPTER, female thread 1 1606 --- ROD, tie 3 3607 108098 WASHER, lock, spring 3 3608 106166 NUT, machine, hex 3 3613 124146 FITTING, elbow, 90, 2 npt, male/female 1 1614 --- LUBRICANT, thread 1 1615 --- SEALANT, anaerobic 1 1616 --- SEALANT, pipe 1 1617 184278 TOOL, wrench, packing nut 1 1618 236272 HOLDER, bottle 1 1619 112279 BOTTLE 1 1620 189221 CAP 1 1621 103927 CLAMP, hose 1 1622 --- TUBE, nylon 45 45623 15F931 RING, lift 1 1624 237063 VALVE, relief 1 1625 108673 TEE, street 1 1626 123724 FITTING, nipple, hex, 1/2 NPT x 3/8 NPT 1 1627 103778 PLUG, pipe 1 1628 113187 CONNECTOR, female, tube 1 1629 --- TUBE, polyethylene, 1/2” OD 1 1
Parts
34 313874E
Hydraulic Vertical Actuator
--- Not for sale.
702
706
701
704
707
708
705
714
715
710
711
712
718
713
716
1
Torque to 100 ft-lb (135 N•m).
Torque to 350 in-lb (39.5 N•m).
Apply a light coating of lubricant to seals andsurfaces specified.
Torque to 50-60 ft-lb (68-81 N•m).
Apply adhesive to surfaces specified.
Torque to 10-12 in-lb (1.1-1.4 N•m).
Apply thread sealant to threads.
Torque to 30-36 ft-lb (41-49 N•m).
Orient ref 701 with date code on castingopposite of 0.25 diameter hole as shown. Ref704 to be on opposite side of 0.25 diameterhole as shown.
1
2
3
4
5
6
7
8
9
9
3
6
5
4
4
4
ti17670a
722, 723
708
3
2
9
Ref Part Description Qty701 257909 DRIVER, hydraulic, vertical,
4.75 in. stroke1
702 --- PLATE, base 1704 16E938 HOUSING, vertical, actuator 1705 15J889 SCREW, hex 4706 113820 SCREW, cap, hex head 3707 103413 PACKING, o-ring 2708 100731 WASHER 4710 15Y715 ROD, tie, 10 in. long 3711 15Y756 PLATE, mounting 1712 15Y726 ROD, tie, 3 in. long 3713 15Y745 PLATE, top, 7.25 diameter 1714 16D023 HOUSING, magnet 1
715 15G747 MAGNET, linear sensor 1716 122988 SCREW, cap, socket, flat 3718 258669 SENSOR 1719 --- LUBRICANT, grease 1720 --- ADHESIVE, retaining 1722 100307 NUT, hex 4723 --- SEALANT, anaerobic 1
Ref Part Description Qty
Parts
313874E 35
Electrical Panels
--- Not for sale.
Base shown for reference only
902
903
901904
ti17671a
905ti17663a
Ref Part Description Qty901 --- MODULE, panel, power, no heat, high
volume1
902 --- MODULE, panel, power, no heat, lowvolume
1
903 115942 NUT, hex, flange head 6904 --- PLUG, hole, 1.5 in. diameter 2905 --- BUSHING, wire protector, snap-in 2906 24E900 CABLE, 5-pin, male/female (not
shown)3
Parts
36 313874E
Power Panel
--- Not for sale.
Ref Part Description Qty1001 --- PANEL, electric, heat 11003 --- MODULE, assy, power, no heat, high
volume1
1004 123452 HOLDER, anchor, wire tie, nylon 41005 116876 WASHER, flat 21006 103833 SCREW, machine 61008 100021 SCREW, cap hex head 11009 100028 WASHER, lock 21010 100015 NUT, hex 21011 --- HARNESS, wire, ground, 8AWG 11012 24D547 HARNESS, wire, male, 2-pin, 16/2 1
10041006
10051006
1011
1003
1012
10011010
1009
1011
1009
1010
_3a
Grounding Detail
Tie wires at this point.1
1
_1a
_2a
Parts
313874E 37
Fluid Control Panel
--- Not for sale.
Ref Part Description Qty1101 --- PANEL, electric, heat 11102 289697 MODULE, cube, GCA, base 11103 102598 SCREW, cap, socket head 41104 289696 MODULE, GCA, cube, FCM 11105 --- HARNESS, wire, ground, terminal,
4 in.1
1106 102063 WASHER, lock 11107 114993 SCREW, machine, pan wash head 11108 100021 SCREW, cap hex head 11109 100015 NUT, hex 21110 100028 WASHER, lock 21111 123452 HOLDER, anchor, wire tie (not shown) 41112 103833 SCREW, machine (not shown) 4
_4a1102
1105
1106
1107
11041103
1101
1109 1110 1105 1110 11081109_2a
_3a
_1a
Parts
38 313874E
Applicator Assembly
--- Not for sale.
1206
1201
Torque to 28 ft-lb (38 N•m).
Tie wires here.
Use electrical tape (1215) to secure scuff jacket.NOTE: Items 1213 and 1214 are used for connecting grounding wire(1208) to
the machine base.
1
2
3
1
ti17672a
ti17673a
1205
1207
1202
1210,1211
1211,1208,1212
1204
12031209
1216
Ref Part Description Qty1201 24F668 MANIFOLD, mix, low viscosity,
mast mount, 1/21
1202 122955 HARNESS, M12 x mini din 21203 123660 CABLE, eurofast, male/female,
6.0 m3
1204 --- TUBE, polyethylene 0.375 OD 12.11205 U70058 FITTING, union, “y”, 3/8 tube 21206 --- SUPPORT, mast, floor mounted 11207 123395 HARNESS, power valve, tank 11208 --- HARNESS, ground, 10AW, 1/4,
#10, 24 ft long1
1209 --- GUARD, spiral, 1/2 in. 181210 123452 HOLDER, anchor, wire tie, nylon 21211 103833 SCREW, machine 31212 100718 WASHER 21213 100028 WASHER, lock (not shown) 21214 100015 NUT, hex (not shown) 21215 --- TAPE, electrical, vinyl 11216 16G194 LABEL, Graco G 1
Ref Part Description Qty
Parts
313874E 39
Parts
40 313874E
Mixer Manifold, 24F668
FIG. 10: Mixer Manifold, Image 1 of 2
Apply pipe sealant to threads.
Apply PTFE tape to threads.
1
2
ti17674a
1304 11309
1
1313 2
13331310
1312
1311
1
1308
1334
1305
1306
1307
1302
1
1
1
1
1
13031
13311329,1330 1 1
1301
1326
1325
1324
1321
1317
1318
1320
1319
1322
1323
1314
2
2
4
3
2
2
1316
1315
Parts
313874E 41
--- Not for sale.
Ref Part Description Qty1301 24H027 MANIFOLD, mix, low viscosity, 1/2 11302 15U426 BUSHING, reducing,
3/4 nptf-1/2nptm2
1303 122763 FITTING, elbow, straight, 3/4 npt, 90 41304 V1M350 VALVE, ball, 3/4 in. 21305 123514 FITTING, tee, run, 3/4, male/ female/
female2
1306 124433 FITTING, swivel, 3/4 npt x 12 JIC,male/female
1
1307 123980 FITTING, swivel, 3/4 x 1/2, male/female
2
1308 121387 FITTING, nipple, 1/2 npt x 3.0 long 21309 918537 APPLICATOR, ball seat, 1/2 port,
60:11
1310 166443 NIPPLE, hex 21311 U70023 VALVE, needle, 3/4 npt, female 21312 15M861 FITTING, reducer, pipe, 3/4 x 1/4 21313 121018 FITTING, elbow, male, swivel,
1/4 npt4
1314 256444 PLATE, mount, mixer 11315 100016 WASHER, lock 41316 111687 SCREW, cap, hex head 41317 --- MANIFOLD, 3-station, air 11318 104472 SCREW, cap 21319 120900 VALVE, solenoid, 3-way 31320 113319 FITTING, air 61321 101754 PLUG, pipe 31322 123550 FITTING, 3/8 tube x 3/8 npt, female/
male1
1323 111881 MUFFLER 21324 100017 SCREW, cap, hex head 41325 100018 WASHER, lock, spring 41326 100338 NUT, jam 41327 --- SEALANT, pipe 11328 --- TAPE, tfe, sealant 11329 16F997 BUSHING, 3/4 x 1/4 npt, male/
female1
1330 16F998 FITTING, plug, 1/4 npt 11331 262205 FITTING, swivel, npt x JIC 11333 24G466 APPLICATOR, ball seat, 1/2 port,
UHMW1
1334 112268 SWIVEL, union 2
Parts
42 313874E
Mixer Assembly, 24H027
† Recommended spare parts. Keep two of each onhand at all times.
--- Not for sale.
1413
Apply pipe sealant to threads.
Apply lubricant to o-ring surfaces beforeassembly
Torque to 33-37 ft-lb (45-50 N•m).
Apply thread sealant.
1
2
3
4
5
1
ti17675a
GaugePort
ServicePort
GaugePort
ServicePort
ti8383a1
1416
14155
1414
1420 1 5
1418 5
1419 5
1417 5
1401
1406
1405
1406
1409
1408140414031407
14023
2
4
2
1
1
1
Ref Part Description Qty1401 192976 MANIFOLD, high pressure 11402 192979 VALVE, check 21403† 114353 SPRING, compression 21404† 108818 BALL 21405 101748 PLUG, pipe 21406 101970 PLUG, pipe 41407† 112973 PACKING, o-ring 21408† 240452 SEAT 21409† 102982 PACKING, o-ring 21410 --- SEALANT, pipe 11411 --- LUBRICANT, grease 11412 --- SEALANT, anaerobic 11413 192977 PIPE, center, mixer manifold 1
1414 124912 SLEEVE, mixer jacket 11415 16G560 MIXER, 3/4 x 23 51416 16G373 FITTING, adapter, mixer, 1 npt 11417 123042 HOSE, vacuum, 1 in. ID 421418 110980 CLAMP, hose 11419 114271 STRAP, retaining 21420 296178 FITTING, union, swivel, 3/4 mpt x
1/2 fpt1
Parts
313874E 43
Floor Mounted Support
--- Not for sale.
Ref Part Description Qty1501 --- PLATE, mating, floor, mast 11502 --- BASE, arm, floor mount 11503 109570 WASHER, plain 41504 100424 SCREW, cap, hex head 4
1501
15031504
1502
Torque to 113 ft-lb (153 N•m).1
124E850_1b
Parts
44 313874E
Hoses
Ref Part Description
Quantity24F726, HOSE,
3/4 ID, 180 in. long,female/male
24F951, HOSE,1/4 ID, 180 in. long,
female/male1601 24F710 HOSE, coupled, 180 in. long, 3/4 iD, 1-1/16 JIC 1
24F950 HOSE, coupled, 180 in. long, 1/4 ID, 1/2-20 JIC 11602 124435 FITTING, union, 12JIC, male x male 1
124726 FITTING, union, JIC05, male x male 1
1602 1601
24F726 shown
Logic Drawings
313874E 45
Logic Drawings230V 3 Phase Power Distribution Box
FIG. 11: Logic Drawings, Page 1
140
149
147
145
142
110
138
136
134
132
130
128
126
124
122
120
118
114
116
112
108
106
104
102
100TH
IS P
AGE
IS F
OR
ASS
EMBL
Y: 2
4C68
3 A
ND
257
764
141
148
144
146
143
111
139
137
135
133
131
129
127
125
123
121
119
115
117
113
109
107
105
103
101
190
199
197
195
192
160
188
186
184
182
180
178
176
174
172
170
168
164
166
162
158
156
154
152
150
191
198
194
196
193
161
189
187
185
183
181
179
177
175
173
171
169
165
167
163
159
157
155
153
151
50-6
0HZ
3PH
/23
0V/
DISC-1
L3 1L3
L2 1L2
L1 1L1
GND
151
1L3
151
1L2
148
1L3
148
1L2
1L1
MIS
CB
VOLU
ME
CB5
1L1
1L2
1L2
PG13
3
755
1L1
CB1
1L1
1L2
1L2
HA
RNES
S24
C516
HA
RNES
S24
C318
30A
5A
MIS
CA
VO
LUM
E
CB6
824
CB10
HA
RNES
S24
C516
HA
RNES
S24
C318
30A
5A
151
1L1
148
1L1
1L3
1L3
1L3
1L1
1L1
1L2
1L2
1L3
1L3
1L3
1L1
1L1
1340
1360
1340
1360
MCM
B VO
LUM
E
PG10
5
1080
1100
331
GND
1840
1860
1840
1860
MCM
A V
OLU
ME
PG15
6
1580
1600
469
GND
L1GN
D
L2 L3
L1GN
D
L2 L311
2016
20
PG18
4
CAP
CAP
1080
1100
1120
1580
1600
1620
1360
1340
1340
1360
POW
ERSU
PPLY
1218
0812
3466
CAN
SPL
ITTE
R
GN
D
POW
ERFI
LTER L1
/P
L2/N
LOAD
LINE
1390
BR
1400
BL
LOCA
TED
IN T
HE
MA
IN P
DB
ENCL
OSU
RECU
STO
MER
MU
ST S
UPP
LY B
RAN
CH C
IRCU
IT P
ROTE
CTI
ON
1 1
2 2
1
BLK
RED
WH
T
BLK
RED
WH
T
Logic Drawings
46 313874E
400V 3 Phase Power Distribution Box
FIG. 12: Logic Drawings, Page 2
140
149
147
145
142
110
138
136
134
132
130
128
126
124
122
120
118
114
116
112
108
106
104
102
100TH
IS P
AGE
IS F
OR
ASS
EMBL
Y: 2
4F14
2
141
148
144
146
143
111
139
137
135
133
131
129
127
125
123
121
119
115
117
113
109
107
105
103
101
151
190
199
197
195
192
160
188
186
184
182
180
178
176
174
172
170
168
164
166
162
158
156
154
152
150
191
198
194
196
193
161
189
187
185
183
181
179
177
175
173
171
169
165
167
163
159
157
155
153
151
50-6
0HZ
3PH
/40
0V/
DISC-1
L3
L2 1L2
L1 1L1
N 1N
GND
1N
151
1L2
148
1N
148
1L2
1L1
MIS
CB
VOLU
ME
CB5
1L1
1N1N
PG13
3
755
1L1
CB1A
1L1
1N1N
HA
RNES
S24
C515
HA
RNES
S24
C318
63A
5A
1L2
MIS
CA
VO
LUM
E
CB6
1L2
1N1N
PG18
4
824
1L2
CB10
A
1L2
1N1N
HA
RNES
S24
C515
HA
RNES
S24
C318
63A
5A
1340
1360
1340
1360
MCM
B VO
LUM
E
PG10
5
1080
1100
331
GND
1840
1860
1840
1860
MCM
A V
OLU
ME
PG15
6
1580
1600
469
GND
L1GN
D
L2 L3
L1GN
D
L2 L3
1080
1100
1580
1600
1360
1340
1340
1360
POW
ERSU
PPLY
1218
0812
3466
CAN
SPL
ITTE
R
GN
D
POW
ERFI
LTER L1
/P
L2/N
LOAD
LINE
1390
BR
1400
BL
LOCA
TED
IN T
HE
MA
IN P
DB
ENCL
OSU
RECU
STO
MER
MU
ST S
UPP
LY B
RAN
CH C
IRCU
IT P
ROTE
CTI
ON
1 1
2
2
1
BLK
WH
T
BLK
WH
T
Logic Drawings
313874E 47
B (Blue) Hydraulic Power Pack
FIG. 13: Logic Drawings, Page 3
BLK
1
240
249
247
245
242
210
238
236
234
232
230
228
226
224
222
220
218
214
216
212
208
206
204
202
200
241
248
244
246
243
211
239
237
235
233
231
229
227
225
223
221
219
215
217
213
209
207
205
203
201
L2L3 L1 GN
D
0X
STA
RT
PB23
5
1 2 3 4 5SO
L240
1 2 3 4 5
STA
RT
FS24
7
1 2 3 4
HYD
-OIL
LO-L
VL
54321
M12
5 P
INM
ALE
M12
5 P
INFE
MA
LE 54321
HA
RNES
S12
3303
DIS
PEN
SE GU
N
RTD
290
4321
M8
4 PI
NM
ALE
M8
4 PI
NFE
MA
LE 4321
OIL
TEM
P
4321
M8
4 PI
NM
ALE
M8
4 PI
NFE
MA
LE 4321
258
265
263
260
256
254
252
250
259
266
262
264
261
257
255
253
251
267
268
4321
M8
4 PI
NM
ALE
MCM
AN
ALO
GLO
W V
OLU
ME
365
CABL
E12
4476
M12
5 P
INM
ALE 54321
CAN
CO
MM
PO
RT
M12
5 P
INM
ALE 54321
CAN
CO
MM
PO
RT
2101
MCM
HI V
OLU
ME
4321
7
SIG
NA
L
SIG
NA
L
COM
MO
N
SIG
NA
L
SIG
NA
L
EXC
SIG
NA
L
M12
5 P
INFE
MA
LE
5
SIG
NA
L
+24V
DC
COM
MO
N
SIG
NA
L
SIG
NA
L
4321
8
M12
5 P
INFE
MA
LE
54321
9
M12
5 P
INFE
MA
LE
5
4321 5
M12
5 P
INM
ALE
HA
RNES
S12
3303
2 3 4 5 1 2 3 4 5 1 2 3 4
4321 5
M12
5 P
INM
ALE
PRES
S XD
UCE
RBL
UE
'B' V
OLU
ME
4321 5
M12
5 P
INM
ALE
B-CO
DE
B-CO
DE
SOL2
34
SOL2
41
OTS
264
OIL
TEM
P
HI
310
319
317
315
312
279
308
306
304
302
300
298
296
294
292
290
287
283
285
281
277
275
273
271
269
311
318
314
316
313
280
309
307
305
303
301
299
297
295
293
291
289
284
286
282
278
276
274
272
270
329
336
334
331
326
324
322
320
330
337
333
335
332
328
325
323
321
4321
6
M8
4 PI
NFE
MA
LE
L1G
ND
L2L3
GND
1080
1100
1120
12
109
4321
M8
4 PI
NFE
MA
LE
1315
8
1310
41
9
32
11 12
6
14
75
11
15 P
IND
SUB
4321
M8
4 PI
NM
ALE
4321
M8
4 PI
NM
ALE
15PI
ND
SUB
GND
RED
BLU
3
5
RTD
292
MO
TOR
TEM
P
EXC
SIG
NA
L
PUM
P PO
SITI
ON
EXC
COM
MO
N
SIG
NA
L
15
8
1310
41
9
32
11 12
6
14
75
LPT2
8025
8669
ENCO
DER
HA
RNES
S24
C516
288
327
MO
TOR
PG10
5
PX26
212
1061
+5VD
C
-SIG
DC
COM
+SIG
SHLD
VALV
E A
SSY
1233
13
DIS
PEN
SE S
IGN
AL
TO H
YDRA
ULI
CD
ISP.
HEA
D F
CM
PUM
PLE
FT
PUM
PRI
GH
T
OPT
ION
L1G
ND
L2L3
GND
1580
1600
HA
RNES
S24
C515
PG10
5
M31
0
1233
67
SIG
NA
L
DC
COM
3 PH
ASE
1 PH
ASE
109
6
2
4
07
5 3
1
B - B
LUE
LOCA
TED
ON
TH
E H
YDRA
ULI
CPO
WER
PAC
K -
VARI
ABL
E RA
TIO
= B
LUE
2A 2B 2C
7A 7B 7C2
7
10
89
3
6 5
11
13
12
SHLD
6
2
4
07
5 3
1
POS
1 =
2000
psi
(DEF
AULT
)
1
1
11
1 1 1
11
1 1
1
1
1
1
1 1
SEE
OPT
ION
AL
MAT
LLE
VEL
SEN
SOR
1
OPT
ION
MAT
LLO
-LVL
OPT
ION
2C1 432
+24V
DC
-24V
DC
SIG
NA
L
Logic Drawings
48 313874E
A (Red) Hydraulic Power Pack
FIG. 14: Logic Drawings, Page 4
BLK
1
378
387
385
383
380
348
376
374
372
370
368
366
364
362
360
358
356
352
354
350
346
344
342
340
338
379
386
382
384
381
349
377
375
373
371
369
367
365
363
361
359
357
353
355
351
347
345
343
341
339
L2L3 L1 GN
D
1 2 3 4 5 1 2 3 4 5 1 2 3 4
54321
M12
5 P
INM
ALE
M12
5 P
INFE
MA
LE 54321
HA
RNES
S12
3303
4321
M8
4 PI
NM
ALE
M8
4 PI
NFE
MA
LE 4321
4321
M8
4 PI
NM
ALE
M8
4 PI
NFE
MA
LE 4321
391
398
396
393
389
406
404
402
392
399
395
397
394
390
388
405
403
400
401
4321
M8
4 PI
NM
ALE
MCM
AN
ALO
GH
I VO
LUM
E22
7
CABL
E12
4476
M12
5 P
INM
ALE 54321
CAN
CO
MM
PO
RT
M12
5 P
INM
ALE 54321
CAN
CO
MM
PO
RT
2101
MCM
LO
W V
OLU
ME
4321
7
SIG
NA
L
SIG
NA
L
COM
MO
N
SIG
NA
L
SIG
NA
L
M12
5 P
INFE
MA
LE
5
SIG
NA
L
+24V
DC
COM
MO
N
SIG
NA
L
SIG
NA
L
4321
8
M12
5 P
INFE
MA
LE
54321
9
M12
5 P
INFE
MA
LE
5
4321 5
M12
5 P
INM
ALE
HA
RNES
S12
3303
2 3 4 5 1 2 3 4 5 1 2 3 4
4321 5
M12
5 P
INM
ALE
PRES
S XD
UCE
RRE
D 'A
' VO
LUM
E
4321 5
M12
5 P
INM
ALE
B-CO
DE
B-CO
DE
SOL3
72
SOL3
78
SOL3
86
OTS
402
OIL
TEM
P
HIHA
RNES
S12
3395
442
451
449
447
444
411
440
438
436
434
432
430
428
426
424
422
419
415
417
413
409
407
443
450
446
448
445
412
441
439
437
435
433
431
429
427
425
423
421
416
418
414
410
408
461
468
466
463
458
456
454
452
462
469
465
467
464
460
457
455
453
4321
6
M8
4 PI
NFE
MA
LE
L1G
ND
L2L3
GND
1580
1600
1620
12
159
4321
M8
4 PI
NFE
MA
LE
1315
8
1310
41
9
32
11 12
6
14
75
11
15 P
IND
SUB
4321
M8
4 PI
NM
ALE
4321
M8
4 PI
NM
ALE
15 P
IND
SUB
GND
RED
BLU
3
5
RTD
429
MO
TOR
TEM
P
EXC
SIG
NA
L
PUM
P PO
SITI
ON
EXC
COM
MO
N
SIG
NA
L
15
8
1310
41
9
32
11 12
6
14
75
ENCO
DER
HA
RNES
S24
C516
420
459
MO
TOR
474
471
470
473
472
475
PG15
6
HYD
-OIL
LO-L
VL
PX40
012
1061
+5VD
C
-SIG
DC
COM
+SIG
SHLD
VALV
E A
SSY
1233
13
PUM
PLE
FT
PUM
PRI
GH
T
1233
67
RTD
428
OIL
TEM
P
EXC
SIG
NA
L
OPT
ION
LPT4
1625
8669
M45
0
L1G
ND
L2L3
GND
1580
1600
HA
RNES
S24
C515
RATI
OCH
ECK
SOL3
79#2
DIS
PEN
SEVA
LVE
3 PH
ASE
PG15
61
PHA
SE
159
6
2
4
07
5 3
1
A -
RED
LOCA
TED
ON
TH
E H
YDRA
ULI
CPO
WER
PAC
K VA
RIA
BLE
RATI
ORE
D 'A
'
2A 2B 2C
7A 7B 7C2
789
3
6 5
10
11
13
12
SHLD
6
2
4
07
5 3
1
2
2
22 2 2
22
2 2 2
2
2
2
2
2
2
POS
2 =
2000
psi
(DEF
AULT
)
SEE
OPT
ION
AL
MAT
LLE
VEL
SEN
SOR
OPT
ION
2
MAT
LLO
-LVL
OPT
ION
2C1 432
+24V
DC
-24V
DC
SIG
NA
L
Logic Drawings
313874E 49
Main Enclosure
FIG. 15: Schematics, Page 5
CON
794
A1
A2
CR50
4
1114
MIS
C B
- BLU
EH
I VO
LUM
E PG13
3
135
792
801
799
797
794
762
790
788
786
784
782
780
778
776
774
772
770
766
768
764
760
758
756
754
752
793
800
796
798
795
763
791
789
787
785
783
781
779
777
775
773
771
767
769
765
761
759
757
755
753
810
817
815
812
808
806
804
802
811
818
814
816
813
809
807
805
803
819
820
861
871
869
867
863
831
859
857
855
853
851
849
847
845
843
841
839
835
837
833
829
827
825
823
821
862
870
865
868
864
832
860
858
856
854
852
850
848
846
844
842
840
836
838
834
830
828
826
824
822
880
887
885
882
878
876
874
872
881
888
884
886
883
879
877
875
873
889
866
1360
1340
2121
MO
TOR
FAN
H
YDH
EAT
EXCH
'R
1340
1360
2121
MO
TOR
FAN
MCM
HA
RNES
S24
C518
1340
1360
SOL2
34SO
L241
HA
RNES
S24
C518
1340
1360
HYD VA
LVE
ASS
Y
1340
1360
CON
800
A1
A2
CR57
3
1114
1340
1360
CON
863
A1
A2
CR64
2
1114
MIS
C A
- RE
D
LOW
VO
LUM
E PG18
4
185
1860
1840
2121
MO
TOR
FAN
H
YDH
EAT
EXCH
'R
1840
1860
2121
MO
TOR
FAN
MCM
HA
RNES
S24
C518
1840
1860
SOL3
72SO
L378
HA
RNES
S24
C518
1840
1860
HYD VA
LVE
ASS
Y
1840
1860
CON
869
A1
A2
CR71
1
1114
1840
1860
M76
2
M77
2
7940
8000
M83
1
M84
1
8630
8690
LOCA
TED
IN T
HE
MA
INSU
PPO
RT E
NCL
OSU
RE
TERM
INA
L ST
RIP
MO
UN
TED
ON
BAC
KPA
NEL
LOCA
TED
IN T
HE
MA
INSU
PPO
RT E
NCL
OSU
RE
TERM
INA
L ST
RIP
MO
UN
TED
ON
BAC
KPA
NEL
USE
D O
NLY
WIT
H P
RIM
ARY
HEA
T O
PTIO
N
USE
D O
NLY
WIT
H H
OSE
HEA
T O
PTIO
N
USE
D O
NLY
WIT
H P
RIM
ARY
HEA
T O
PTIO
N
USE
D O
NLY
WIT
H H
OSE
HEA
T O
PTIO
N
230V
AC
PO
WER
TO
TH
E H
YDR
AU
LIC
PO
WER
VA
LVE
230V
AC
PO
WER
TO
TH
E FA
N
MO
TOR
230V
AC
PO
WER
TO
TH
E FA
N
MO
TOR
230V
AC
PO
WER
TO
TH
E H
YDR
AU
LIC
PO
WER
VA
LVE
230V
AC
PO
WER
TO
TH
E FA
N
MO
TOR
230V
AC
PO
WER
TO
TH
E FA
N
MO
TOR
12
BL BR
BL BR
Logic Drawings
50 313874E
B (Blue) Hydraulic Power Pack and Dispense Head Pneumatics
FIG. 16: Schematics, Page 6
930
939
937
935
932
900
928
926
924
922
920
918
916
914
912
910
908
904
906
902
898
896
894
892
890
931
938
934
936
933
901
929
927
925
923
921
919
917
915
913
911
909
905
907
903
899
897
895
893
891
948
955
953
950
946
944
942
940
949
956
952
954
951
947
945
943
941
957
958
999
1009
1007
1005
1001
969
997
995
993
991
989
987
985
983
981
979
977
973
975
971
967
965
963
961
959
1000
1008
1003
1006
1002
970
998
996
994
992
990
988
986
984
982
980
978
974
976
972
968
966
964
962
960
1018
1025
1023
1020
1016
1014
1012
1010
1019
1026
1022
1024
1021
1017
1015
1013
1011
1027
1004
TP
BA
AB
PUM
P PO
SITI
ON
+5 V
DC
GN
D
SIG
NA
L
HV LP
T280
LV LP
T416
HV SO
L241
LV SO
L378
HV SO
L234
LV SO
L372
1233
13
+5 V
DC
GN
D
SIG
NA
L
MOIL
OVE
RTEM
P
SWIT
CH
OIL
TEM
PRT
D O
PTIO
NA
LH
V O
TS26
4LV
OTS
402
FIXE
D R
ATIO
MAC
HIN
E FR
ON
TFA
CIN
G P
UM
PS
VARI
ABL
E RA
TIO
VERT
ICA
L PU
MP
'B' B
LUE
'A' R
EDIS
O L
UBE
PUM
P
HV
RTD
290
LV R
TD42
8
COO
LER
FILT
ER15
J437
HV
M31
0LV
M45
0
PRES
SURE
GAU
GE
OPT
ION
AL
PRES
SURE
RELI
EFVA
LVE
PUM
P
HYD
. FA
NH
V M
762
LV M
831
MCM
FA
NH
V M
772
LV M
841
HYD
RAU
LIC
CYLI
ND
ER
OIL
LEV
ELSE
NSO
RO
PTIO
NA
L
HV
PX26
2LV
PX4
00
LOCA
TED
ON
TH
E M
AIN
HYD
RAU
LIC
POW
ER P
ACK
A
B
DIS
PEN
SE H
EAD
PN
EUM
ATIC
S
LOCA
TED
ON
DIS
PEN
SE H
EAD
5 1 3
4 2
SOL-
379
1 1
EXH
P
SOL-
240
SOL-
386
CLO
SED
R
ED D
ISPE
NSE
VA
LVE
105
106
CLO
SED
B
LUE
DIS
PEN
SE V
ALV
E10
3
104
CLO
SECL
OSE
D
BLU
E RA
TIO
CH
ECK
VALV
E
OPE
N
101
102
CLO
SED
R
ED R
ATIO
CH
ECK
VALV
E
OPE
N
101
RED
MCM
PO
RT 2
A
BLU
E M
CM P
ORT
2A
RED
MCM
PO
RT 7
B
5 3
4 2
5 3
4 2
1234
78
1209
00
1209
00
1209
00
CLO
SE
OPE
N
CLO
SE
OPE
N
CLO
SE
101
102
103
104
105
106
Technical Data
313874E 51
Technical Data
DimensionsThe dimensions of the machine vary by machine layout.The distance from the machine base to the dispensestand can be varied significantly because of the hoses.
Air Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85-100 psi (0.59-0.69 MPa, 5.9-6.9 bar)
Wetted Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Stainless steel, UHMW
Hydraulic Reservoir Capacity . . . . . . . . . . . . . . . . . . . . 8 gal. (30 liters) each
Recommended Hydraulic Fluid . . . . . . . . . . . . . . . . . . . Citgo A/W Hydraulic Oil, ISO Grade 46
Weight (varies by machine layout) . . . . . . . . . . . . . . . . . 1390 lb (630 kg)
Ref in. (mm)A (Height) 79 (2007)B (Width) 63 (1600)C (Depth) 115 (2921)
A
C
B
ti17663a
All written and visual data contained in this document reflects the latest product information available at the time of publication.Graco reserves the right to make changes at any time without notice.
For patent information, see www.graco.com/patents.
This manual contains English. MM 313874
Graco Headquarters: MinneapolisInternational Offices: Belgium, China, Japan, Korea
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA
Copyright 2010, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.www.graco.com
Revised November 2014
Graco Standard WarrantyGraco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects inmaterial and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warrantypublished by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined byGraco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s writtenrecommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faultyinstallation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution ofnon-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment withstructures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation ormaintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification ofthe claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returnedto the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs willbe made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITEDTO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental orconsequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR APARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOTMANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject tothe warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of thesewarranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, orthe furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, thenegligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERSThe Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into,given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que larédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suitede ou en rapport, directement ou indirectement, avec les procédures concernées.
Graco InformationFor the latest information about Graco products, visit www.graco.com.
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505