i. rationale for regulation country rationale ......sni 04-3892.1-2006 v iec 60884-1 (2002-06) idt s...

15
as of 17 Mei 2016 Page 1 of 15 I. COUNTRIES WITH MANDATORY STANDARDS FOR GOVERNMENT PROCUREMENT ONLY INDONESIA I. RATIONALE FOR REGULATION COUNTRY RATIONALE FOR REGULATION Indonesia Consumer Protection II. REGULATION BODY COUNTRY REGULATORY BODY Indonesia Ministry of Industry Ministry of Energy and Mineral Resources Ministry of Trade

Upload: others

Post on 26-Jan-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

  • as of 17 Mei 2016

    Page 1 of 15

    I. COUNTRIES WITH MANDATORY STANDARDS FOR GOVERNMENT PROCUREMENT ONLY

    INDONESIA

    I. RATIONALE FOR REGULATION

    COUNTRY RATIONALE FOR REGULATION

    Indonesia Consumer Protection

    II. REGULATION BODY

    COUNTRY REGULATORY BODY

    Indonesia

    Ministry of Industry Ministry of Energy and Mineral Resources Ministry of Trade

  • as of 17 Mei 2016

    Page 2 of 15

    III. LEGISLATIVE FRAMEWORK

    COUNTRY LEGISLATIVE FRAMEWORK

    Indonesia 1. Act No. 8 / 1999 concerning Consumer Protection

    2. Act No. 3 / 2014 concerning Industry

    3. Act No. 7 / 2014 concerning Trade

    4. Act No. 20 /2014 concerning Standardization and Conformity Assessment

    5. Government Regulation No. 102/2000 concerning National Standardization

    6. Decree of the Minister of Industry No. 86/M-IND/PER/9/2009 concerning the Implementation of

    SNI in Industrial Sector

    7. Decree of the Minister of Industry No. 51/M-IND/PER/3/2012 concerning The Procedures for

    Recognition of Certification Product of Electrical and Electronic Equipment Issued by

    Conformity Assessment Bodies Listed in ASEAN

    8. Decree of the Minister of Energy and Mineral Resorces No. 01/2016 concerning The

    Procedures for Recognition of Product Certification and Product Test Report of Electrical and

    Electronic Equipment Issued by Conformity Assessment Bodies Listed in ASEAN

    9. Decree of the Minister of Trade No. 24/M-DAG/PER/4/2016 concerning Standardization on

    Trade Sector

  • as of 17 Mei 2016

    Page 3 of 15

    IV. MANDATORY STANDARDS

    Product type or grouping

    STANDARDS

    State reason if MOD

    Indicate whether requires:

    Safety (S), Environment

    (E), EMC, or

    combination

    Domestic Standards

    Please tick box if

    mandatory Relevant International Standards

    Extent of Alignment

    Incandescent lamps

    SNI 04-3560-1994 V IEC 60064 Ed.6 (1993-12)

    IDT S

    Self-ballast lamp for general lighting service SNI 04-6504-2001 V IEC 60968 Ed.1.0 (1988-11)

    IDT S

    Plugs and socket-outlets for household and similar purposes. Part 1 : General requirement

    SNI 04-3892.1-2006 V IEC 60884-1 (2002-06)

    IDT S

    Switches for household installations and similar fixed electric. Part 1: General requirements

    SNI 04-6203.1-2006 V IEC 60669-1 (2000)

    IDT S

    Circuit breakers for over current protection for household and similar installation. Part 1 : Circuit breaker for a.c operated

    SNI 04-6507.1-2002

    SNI 04-6507.1-2002/Amd1. 2006

    V IEC 60898-1 (2003)

    IDT S

    Electrical appliances for household usages and other similar types of safety products; Part 2-80. Special requirements for electric fan

    SNI 04-6292.2.80-2006 V IEC 60335-2-80(2004-03)

    IDT S

    Lamp controlgears - Part 1: General and safety requirements

    SNI 04-6959.1-2003 V IEC 61347-1 (2000-10) IDT

    S

    Lamp controlgears - Part 2-3: Particular requirements for a.c. supplied electronic ballasts for fluorescent lamps

    SNI 04-6959.2.3-2003 V IEC 61347-2-3 (2000-10)

    IDT

    S

  • as of 17 Mei 2016

    Page 4 of 15

    Product type or grouping

    STANDARDS

    State reason if MOD

    Indicate whether requires:

    Safety (S), Environment

    (E), EMC, or

    combination

    Domestic Standards

    Please tick box if

    mandatory Relevant International Standards

    Extent of Alignment

    Residual current operated circuit - breakers without integral overcurrent protection for household and similar uses (RCCB) - Part 1: General rules

    SNI 4 -6956.1-2003 V IEC 61008-1 (1996-12) IDT S

    Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB’s) - Part 2-1: Applicability of the general rules to RCCB’s functionally independent of line voltage

    SNI 04-6956.2.1-2005 V IEC 61008-2-1 (1990-12)

    IDT S

    Luminaires - Part 1: General requirements and tests

    SNI 4 -6973.1-2005 V IEC 60598-1 (2003)

    IDT

    S

    Luminaires - Part 2-1: Particular requirements - Fixed general purpose luminaires

    SNI 4 -6973.2.1-2005 V IEC 60598-2-1 (1979) IDT

    S

    Luminaires - Part 2-2: Particular requirements - Recessed luminaires

    SNI 4 -6973.2.2-2005 V IEC 60598-2-2 (1997)

    IDT

    S

    Luminaires - Part 2-3: Particular requirements - Luminaires for road and street lighting

    SNI 4 -6973.2.3-2005 V IEC 60598-2-3 (2002)

    IDT

    S

    Luminaires - Part 2-5: Particular requirements – Floodlights

    SNI 4 -6973.2.5-2005 V IEC 60598-2-5 (1998): IDT

    S

    Primary Battery - part 1: General SNI 04-2051.1-2004 V

    IEC 60086-1 (2000)

    IDT

    S

    Primary Battery - part 2: Electrical and Physical Requirement

    SNI 04-2051.2-2004 V

    IEC 60086-2 (2000)

    IDT

    S

  • as of 17 Mei 2016

    Page 5 of 15

    Product type or grouping

    STANDARDS

    State reason if MOD

    Indicate whether requires:

    Safety (S), Environment

    (E), EMC, or

    combination

    Domestic Standards

    Please tick box if

    mandatory Relevant International Standards

    Extent of Alignment

    PVC insulated cables with a rated voltage up to 450/750 V - Part 3: Non-sheated cables for fixed wiring

    SNI 04-6629.3-2006 V IEC 60227-3(1997-11) IDT

    S

    PVC insulated cables with a rated voltage up to 450/750 V - Part 4: Sheated cables for fixed wiring

    SNI 04-6629.4-2006 V IEC 60227-4(1997-12) IDT

    S

    PVC insulated cables with a rated voltage up to 450/750 V - Part 5: Flexible cables

    SNI 04-6629.5-2006 V IEC 60227-5(2003-07) IDT

    S

    Safety of household and similar electrical appliances — Part 2-41 : Particular requirements for pumps

    SNI 04-6292.2.41-2003

    V IEC 60335-2-41 (2002-10)

    IDT

    S

    Household and similar electrical appliances – Safety – Part 2-3: Particular requirements for electric irons

    SNI 04-6292.2.3-2003 V IEC 60335-2-3 (2002-03)

    IDT

    S

  • as of 17 Mei 2016

    Page 6 of 15

    Product type or grouping

    STANDARDS

    State reason if MOD

    Indicate whether requires:

    Safety (S), Environment

    (E), EMC, or

    combination

    Domestic Standards

    Please tick box if

    mandatory Relevant International Standards

    Extent of Alignment

    Audio, video and similar electronic apparatus —Safety requirements

    SNI 04-6253-2003 V IEC 60065 (2001–12) MOD 4.1.3

    Unless

    otherwise

    specified,

    the tests

    are carried

    out under

    normal

    operating

    conditions

    at:

    -

    anambient

    temperatur

    e between

    20 oC and

    35 oC

    - a relative

    humidity of

    70 % ±

    15%

    maximum

    S

  • as of 17 Mei 2016

    Page 7 of 15

    Product type or grouping

    STANDARDS

    State reason if MOD

    Indicate whether requires:

    Safety (S), Environment

    (E), EMC, or

    combination

    Domestic Standards

    Please tick box if

    mandatory Relevant International Standards

    Extent of Alignment

    Household and similar electrical appliances - Safety - Part 2-40: Particular requirements for electrical heat pumps, air-conditioners and dehumidifiers

    SNI IEC 60335-2-40:2009 V IEC 60335-2-40 Ed 4.2 (2005-07)

    IDT

    S

    Household and similar electrical appliances - Safety - Part 2-24: Particular requirements for refrigerating appliances, ice-cream appliances and ice makers

    SNI IEC 60335-2-24:2009

    V IEC 60335-2-24 Ed 6.1 (2005-04)

    IDT

    S

    Household and similar electrical appliances - Safety - Part 2-7: Particular requirements for washing machines

    SNI IEC 60335-2-7:2009 V IEC 60335-2-7 (2004-11)

    IDT

    S

  • as of 17 Mei 2016

    Page 8 of 15

    V. MODE OF REGULATION AND TYPES OF CONFORMITY ASSESSMENT REGIMES

    COUNTRY TYPES OF CON-FORMITY ASSESS-

    MENT REGIMES

    MODE OF REGULATION

    Indonesia Technical Regulation based on SNI

    Technical regulation on EEE by adopting partially or fully technical specification and/or parameter of SNI is stipulated by Ministerial Decree taking into account safety, security, health, environment, moral hazard, and economical aspects, that are equally imposed to both domestic and imported products which are traded in Indonesian teritory.

    Manufacturers of EEE which are technically regulated based on SNI shall fulfill the SNI requirements and shall affix the SNI mark on the products, packages and/or label of their products

    Product Registration to get NPB (for imported products) or NRP (for domestic products)

    Pre-market surveillance over traded goods produced domestically, shall be done through Product Registration Number (Nomor Registrasi Produk - NRP)

    Pre-market surveillance over imported of EEE shall be done through Goods Registration Number (Nomor Pendaftaran Barang – NPB),

    NRP and NPB shall be issued by the Director of Standardization and Quality Control, Ministry of Trade

    The validity of NRP and NPB are in accordance with the validity period of SPPT SNI.

    NRP or NPB shall affix underneath SNI Mark and/or other recognized conformity mark, on to their products or packages.

  • as of 17 Mei 2016

    Page 9 of 15

    COUNTRY TYPES OF CON-FORMITY ASSESS-

    MENT REGIMES

    MODE OF REGULATION

    Registration of CAB CAB issuing an SNI Mark Product Certification can be a domestic or foreign product certification body supported by accredited testing laboratories and/or inspection institutions.

    Domestic CAB shall be accredited by KAN according to its scopes, CAB shall be

    registered to the Directorate of Standardisation and Quality Control, Ministry of Trade.

    All CAB which have the scope of mandatory SNI’s requirements shall be accredited by National Accreditation Body of Indonesia (KAN) and assigned by Minister of Industry

  • as of 17 Mei 2016

    Page 10 of 15

    VI. FLOWCHART OF INDONESIA’S REGIME

    PROCEDURES FOR RECOGNITION OF CERTIFICATES OF ELECTRICAL EQUIPMENTS AND ELECTRONIC PRODUCTS

    FROM CONFORMITY ASSESSMENT BODIES IN ASEAN COUNTRIES

    AMS Indonesia

    Listed Product Certification Body for EEE

    Listed Testing Lab. for EEE

    Product Certification Body

    SPPT SNI according to certification type ISO/IEC 17067

    Product EEE ASEAN

    Legend: 1. Using Certificate of Conformity issued by Listed Product Certification Body 2. Using Testing report issued by Listed Testing Lab.

    Listed Testing lab have to be accredited for full parameter of the standards 3. Direct to listed Indonesia Product Certification Body

    Indonesia Product Certification Body may ask for additional requirement if necessary For point 1 & 2 requires a submission of Form D-ATIGA

    3

    1

    2

  • as of 17 Mei 2016

    Page 11 of 15

    VII. MAINS VOLTAGE, FREQUENCY AND MAINS PLUG CONFIGURATION

    Country Mains

    Voltage and Tolerance

    Mains Frequency and Tolerance

    Applicable Legislation

    Mains Plug Configuration

    Domestic Standard

    Please tick box if mandatory

    Relevant International Standard

    Extent of Alignment -

    Diagram of Mains Plug Configuration-

    Indonesia 230 5% 50 5% SNI 04-3892.1-2006

    Plugs and socket-outlets for household and similar purposes. Part 1 : General requirement

    V

    IEC 60884-1

    Ed.3.0(2002,am.1(2006)

    IEC 60884-2-1 Ed.1.0(1987)

    IEC 60884-2-3 Ed.1.0(1989) (0nly for the

    safety)

    SNI 04-3892.2.3-

    2000:Plugs and Sockets-Outlets for household and similar purposes;Part 2.3:Particular Requirement for switched socket outlets without interlock for fixed installation.

  • as of 17 Mei 2016

    Page 12 of 15

    Country Mains Voltage and Tolerance

    Mains Frequency and Tolerance

    Applicable Legislation

    Mains Plug Configuration

    Domestic Standard

    Please tick box if mandatory

    Relevant International Standard

    Extent of Alignment -

    Diagram of Mains Plug Configuration-

    SNI 04-6202-

    2000: Plugs and Sockets-Outlets and couplers for industrial purposes;Part 3: Particular Requirement for plugs, socket outlets, connectors and appliance inlets for use in explosive gas atmospheres.

    SNI 04-0225-

    2000/Amd1-2006 on Amendment 1 of Indonesian National Standard for General Requirements on Electrical Installation

    V IEC 60364 (series)

  • as of 17 Mei 2016

    Page 13 of 15

    VIII. MARKING/LOGO :

    Affixing SNI and NRP

    Note:

    101 : Product Certification Body certifying the products 010 : Factory Location 000001 : Registration Number in Directorate of Standardization and Quality Control

  • as of 17 Mei 2016

    Page 14 of 15

    Affixing SNI and NPB

    Note:

    101 : Product Certification Body certifying the products 156 : Country of Origin 000001 : Registration Number in Directorate of Standardization and Quality Control

  • as of 17 Mei 2016

    Page 15 of 15

    IX. CONTACT PERSON

    Country JSC EEE

    Indonesia Representative Officer Chandrini M. Dewi Director of Standardization and Quality Control Directorate General of Consumer Protection and Trade Compliance Ministry of Trade Jl. Raya Bogor KM 26 Ciracas - Jakarta Timur Telp : (021) 8710321/3Fax : 62-21-3863928 E-mail : [email protected], [email protected] Contact Person Konny Sagala, S.Si Head of Center for Cooperation on Standardization - BSN BPPT I Building Jl. M.H. Thamrin No. 8, Kebon Sirih Jakarta Pusat 10340 Indonesia Phone : 62-21-3927422 Fax : 62-21-3927527 E-mail : [email protected], [email protected] Designating Body Dr. Zakiyah Head of Center for Application on Standardization - BSN BPPT I Building Jl. M.H. Thamrin No. 8, Kebon Sirih Jakarta Pusat 10340 Indonesia Phone : 62-21-3927422 Fax : 62-21-3927527 E-mail : [email protected], [email protected]

    mailto:[email protected]:[email protected]:[email protected]:[email protected]:[email protected]:[email protected]