ibm system storage neues zu disk, svc und “tape” · ibm system storage neues zu disk, svc und...

31
IBM TSM User Forum 2009 IBM System Storage Neues zu Disk, SVC und “Tape” Manuel Schweiger IT Specialist

Upload: doantuong

Post on 13-May-2018

219 views

Category:

Documents


0 download

TRANSCRIPT

IBM TSM User Forum 2009

IBM System StorageNeues zu Disk, SVC und “Tape”

Manuel SchweigerIT Specialist

IBM TSM User Forum 2009

Agenda

Disk – DS8700 Announcement SVC “Tape”

2

IBM TSM User Forum 2009

3

IBM System Storage DS8700 Announcement (R5.0)

Key Dates

Announce date October 20, 2009 GA date October 23

Release 5.0 key messages

Performance: Availability & Resiliency Flexibility & Scalability Security Investment Protection

Performance, resiliency, and security to satisfy the world’s most demanding clients

IBM TSM User Forum 2009

4

What’s New – Why Move to DS8700

Introducing the New DS8700

Performance Up to over 150% performance boost with new IBM POWER6-based controllers New, faster PCI Express (PCI-E) internal fabric enables much higher performance and

scalability Almost 70% faster ASIC on the device adapters Increased FlashCopy performance in every metric Increased SSD performance on sequential reads

Availability Single model, scalable via concurrent upgrade of all components Shorter service windows with faster concurrent microcode updates Better than 99.999% availability

Investment Protection and Scalability DS8700 architecture allows for future expansion of additional controllers and future 8Gb Host

Adapters Future features, such as SSD optimization and M/GM Multiple Session coming soon

Management Simplified management and application-aware FlashCopy

Security Full Disk Encryption enhancements address PCI-DSS compliance

The Next Chapter in IBM’s Flagship Disk Platform

IBM TSM User Forum 2009

Changing from DS8000 to Follow-on

5

DS8700PCIe cable I/O attach

Change in I/O

structure

P5

P5

P5

P5

Disks

Disks

P6

P6 P6

RIO RIO

PCIe

 cab

les

DS8000RIO I/O attach

DS8700PCIe cable I/O attach

New I/O attach

Change in I/O

structure

P6 server

P6

New IO bays are directly connected to the servers via point­to­point PCI­e cables.

IO Towers no longer share common ‘loops’, they connect directly to each server via separate cables and link cards.

The server­to­server communication path continues to use RIO, but is now isolated from IO traffic.

4.7 Ghz P6 570 x2 Cache 32 ­ 384GB 4 Gb/s FC / FICON 2 Gb/s disk array

IBM TSM User Forum 2009

Proven Server-Based Architecture

6

Exceptional performance Up to over 150% performance improvement for sequential workloads Up to 100% performance improvement for random workloads

Improved Reliability, Availability, Serviceability

Higher Scalability Enables higher scalability through POWER6 design, increased cache

size (384 GB), and higher RAS

Greater Energy efficiency Over 50% more IOPS/Watt

  All these benefits with minimal changes to existing firmware and codebase …         … which translates to higher system reliability and information availability

New IBM POWER6 processor complex offers…

IBM TSM User Forum 2009

7

New PCI-Express Internal Fabric

Performance PCI-E fabric increases data throughput, especially for sequential workloads

Availability PCI-E fabric reduces the impact of hardware failures

Scalability Scale internal bandwidth by adding additional data links or "lanes”

Flexibility and upgradability PCI fabric enables single DS8700 model with flexibility to fit customer requirements Concurrent upgradability of all components from small to large configurations

Enabling future growth

Lower acquisition costs by enabling non­disruptive upgrades from base 2­way model to full­blown 4­way model!

IBM TSM User Forum 2009

Summary - DS8700 (2-way/4 way base frame) 242x model 941

I/O Drawers (slightly larger at 5U)4GB features only (no 2GB/ no ESCON)Drawers attached via PCI-E switchNew Host Attachment and Device Adapter features (PCI-E)

Batteries

Power Supplies

P6 (POWER 6) Servers

Feature specified 2-way/4-way2-way processor memory size 32GB-128GB4-way processor memory size 32GB-384GB4-way required for expansion frame models

HMC – new laptop

Familiar Layout

8

IBM TSM User Forum 2009

DS8700 (4-Way with two expansion frames, Rear view)

Non­disruptive MES of first expansion frame

Capable of being extended to 5 frames

Expansion frame with IO drawers must be model 94E

Expansion Frames without IO drawers can be either 94E/92E

941 Base94E/92E Position 2 (#0341) 94E Position 1 (#0340)9

IBM TSM User Forum 2009

Binary Compatibility

2004-6 2007-9

POWER5 POWER6POWER PC / POWER

1999-4

130 nm 90 nm 65 nm

L2 Cache

4.7GHz

AdvancedSystem Features

Distributed Switch

180 nm

Distributed Switch

Shared L2

1+ GHzCore

1+ GHzCore

130 nm

1.9GHzCore

Distributed Switch

Shared L2

1.5+GHzCore

Shared L2

2.2GHzCore

Distributed Switch

2.2GHzCore L2 Cache

4.7GHz Core

AdvancedSystem Features

1.5 GHzCore

Distributed Switch

Shared L2

1.5 GHzCore

Chip Multi Processing - Distributed Switch - Shared L2Dynamic LPARs (32)

DS8000DS8000 Turbo

DS8700 leverages the DS8000’s highly reliable code base! 

ESS (Shark)

The IBM POWER processor has been behind the success of IBM enterprise storage beginning with the Enterprise Storage Server (Shark) in 1999

Benefit: a steady, 10-year lineage of RAS improvements!

IBM POWER and DS8700 Reliability and Resiliency

DS8700

FUTURE

POWER xxx

DS8XXX

10

IBM TSM User Forum 2009

11

Improved and Simplified Management GUI enhancements

Updated every 60sec.

Number of racks shown matches racks in the storage unit

New System Summary Panel

–Overview tab displays system configuration and real-time performance data for a 5 minute sampling interval

IBM TSM User Forum 2009

12

System Summary Panel – Overview Tab

Hardware Explorer tab shows system hardware and a mapping between logical configuration objects and drives (e.g., drives belonging to an extent pool or array)

Real images show exactly what bays are populated with what devices

R5.0R5.0

IBM TSM User Forum 2009

13

The DS8700 announcement introduces the most advanced model in IBM’s DS8000 lineup with up to over a 150% boost in performance. This new hardware refresh not only offers much higher performance, it also builds on the DS8000’s unrivaled reputation for reliability and investment protection by maintaining its IBM POWER-based architecture over generations of new models.

This release underscores the commitment to our flagship enterprise disk platform and enables us continue providing an ideal combination of optimized performance, scalability, reliability, and value that our most demanding customers expect from IBM.

Announcement Summary

IBM TSM User Forum 2009

Agenda

Disk – DS8700 Announcement SVC – v5 Announcement “Tape”

14

IBM TSM User Forum 2009

15

New SVC 2145-CF8 Storage Engine

New SVC engine based on IBM System x3550M2 server Intel® Xeon® 5500 2.4 GHz quad-core processor Triple cache size to 24GB (with future growth possibilities) Four 8Gbps FC ports

Bandwidth twice that of the Model 8G4 Expect double MB/s and up to double IOPS

of Model 8G4 Significant price/performance improvement Enables support of more demanding and larger configurations with fewer SVC

engines Support for Solid State Drives (up to four per SVC node) enabling scale-out

high performance SSD support with SVC New engines may be intermixed in pairs with other engines in SVC clusters

Mixing engine types in a cluster results in VDisk throughput characteristics of the engine type in that I/O group

Cluster non-disruptive upgrade capability may be used to replace older engines with new CF8 engines

IBM TSM User Forum 2009

SVC Configurations With 2145-CF8

Minimum Configuration

(One I/O Group)

Maximum Configuration

(Four I/O Groups)

Cache 48GB 192GB

8Gb Fiber Channel Ports

8 32

1Gb iSCSI Ports 4 16

SSDs 1 32

Mirrored SSD Capacity

146GB (two SSDs) 2.4TB

16

IBM TSM User Forum 2009

17

SVC Software Version 5

Support for iSCSI server attachment

Replication enhancements including Multiple Cluster Mirror, increased number of remote copy relationships, and Multi-Target Reverse FlashCopy Supports consolidated disaster recovery site servicing more than one production location Enables larger configurations to be protected with up to 8192 MM/GM relationships FlashCopy targets may be used almost immediately as restore points enabling faster

recovery

New 64-bit SVC software base Supports all SVC engines available since October 2005 (8F2, 8F4, 8G4, 8A4, CF8)

Cache management enhancements Improves throughput up to 15% for existing systems, especially for write I/Os

Available for existing customers with current subscription and support at no charge Nondisruptive upgrade from SVC software 4.3.1

IBM TSM User Forum 2009

Max 4 clusters connected by partnerships either directly or indirectly All must be at 5.1 even if a cluster is only in one partnership

Unsupported configuration: 5 clusters in a connected set

A VDisk can only be in one MM or one GM relationship A FlashCopy target cannot be a MM or GM source

Enables Metro and Global Mirror relationships between up to four SVC clusters Three site Metro-Global Mirror like DS8K not supported Replication of a VDisk to multiple sites not supported

Multiple Cluster Mirroring Configuration Rules

A

B

D

C A

B D

C

A B DC

A B DC E

IBM TSM User Forum 2009

19

Thin Provisioning Enhancements: Zero Detect

When using Virtual Disk Mirroring to copy from a fully-allocated virtual disk to a space-efficient (thin provisioned) virtual disk, SVC will not copy blocks that are all zeroes Disk space is not allocated for unused space or formatted space that is all zeroes

When processing a write request, SVC will detect if all zeroes are being written and will not allocate disk space for such requests Helps minimize disk space used for space-efficient virtual disks Helps avoid space utilization concerns when formatting vdisks Supported only on Model CF8 storage engines

IBM TSM User Forum 2009

Uninterruptible storage failover between two datacenters

If location (A) fails, (B) can work with the same virtual HDDs and vice versa.

Great for VMware environments Virtual machine moves with

VMotion Vdisk moves with SVC

VMHost Failover

LUN1 LUN1'

RZ (A) RZ (B)

SVC 1 node A SVC 1 node B

 FC Long Wave Signaldistanz (10 km) 

Host

VMHost

Host

High Availability Storage SolutionSVC Stretched Cluster

IBM TSM User Forum 2009

SANVolume Controller

SAN Volume Controller Version 5 Supported Environments

8Gbps SAN fabric

HPMA, EMA

MSA 2000, XP EVA 6400, 8400

HitachiLightningThunder

TagmaStoreAMS 2100, 2300, 2500

WMS, USP

EMCCLARiiONCX4-960

Symmetrix

MicrosoftWindowsHyper-V

IBM AIX

IBM i 6.1

SunSolaris

HP-UX 11iTru64

OpenVMS

Linux(Intel/Power/zLinux)

RHELSUSE 11

IBMBladeCenter

SAN

SANVolume Controller

Continuous CopyMetro/Global Mirror

Multiple Cluster Mirror

VMwarevSphere 4

Point-in-time CopyFull volume, Copy on write

256 targets, Incremental, Cascaded, ReverseSpace-Efficient, FlashCopy Mgr

NovellNetWare

SunStorageTek

IBMDS

DS3400DS4000

DS5020, DS3950DS6000DS8000

IBMESS,FAStT

1024Hosts

IBMN series

NetAppFAS

SGI IRIX

IBM N series GW NetApp V-Series

IBM TS7650G

BullStoreWay

FujitsuEternus

30008000 Models 2000 & 1200

4000 models 600 & 400

NECiStorage

For the most current, and more detailed, information please visit ibm.com/storage/svc and click on “Interoperability”.

Space-Efficient Virtual Disks

New

Entry Edition

Virtual Disk MirroringNew

AppleMac OS

PillarAxiom

IBMXIV

DCS9550DCS9900

IBMz/VSE

New

New

New

New

SSDNew

Native iSCSINew

New

NewNew

New

21

IBM TSM User Forum 2009

Agenda

Disk – DS8700 Announcement SVC – v5 Announcement “Tape” – DeDup VTL TS7650

22

IBM TSM User Forum 2009

23

1. Data-agnostic factoring of up to 25x

2. Enterprise Class inline performance +1000MB/s

3. Unmatched scalability: 1 PB physical data

4. 100% data-integrity during de-dupe process

5. Simple, non-disruptive deployment

6. Software-only solution: hardware agnostic

No other de­dupe technology meets all these criteria!Most elements of new­data backed up today already exist in previous backups

TS7650 Criteria

IBM TSM User Forum 2009

24

“Filtered” data

24

FC Switch TS7650G

Backup Servers

Disk Arrays

New Data Stream Repository

MemoryResidentIndex

IBM TSM User Forum 2009

2525

Active-active true clustered nodes High performance (1000MB/s sustainable) Highly available

FC Switch

2 Node ClusterTS7650G x 2

Backup ServersBackup Arrays

     High capacity, highly scalable

     Easily manageable    two nodes working together    one repository

TS7650G - ProtecTIER De-Duplication Gateway

IBM TSM User Forum 2009

De­Dupe

Backup Server

De­DupeOverlap

Tape Library TruckTSM (and other VTL)

Truck

8:00 AM

Tape Library

2:00 AM

De­Dupe

ProtecTIER VT

8:00 PM

Inline Processing (TS7650)

Backup Server

8:00 PM

Post Processing (TSM)

De­Dupe

SLA is Met

Differences between TS7650 and TSM DeDupWhich solution is the best for me?

IBM TSM User Forum 2009

27

1. Slice data into chunks (fixed or variable)

2. Generate Hash per chunk and save

3. Slice next data into chunks and look for Hash Match

4. Reference data previously stored

A B C D E

A B C D E

Ah ChBh Dh Eh

Hash Based Approach (TSM)

IBM TSM User Forum 2009

28

1. Look through data for similarity

1. Read elements that are most similar2. Diff reference with version – will use several elements

3. Matches factored out – unique data added to repository 

Element A Element B Element C

New Data Stream

HyperFactor Approach – (TS7650)

IBM TSM User Forum 2009

Differences between TS7650 and TSM DeDupWhich solution is the best for me?

TSM DeDup Diskpool < 6TB and/or no VTL needed

TS7650 Diskpool > 6TB High Performance needed VTL wanted

29

IBM TSM User Forum 2009

IBM Corporation 1994-2009. All rights reserved.References in this document to IBM products or services do not imply that IBM intends to make them available in every country.

Trademarks of International Business Machines Corporation in the United States, other countries, or both can be found on the World Wide Web at http://www.ibm.com/legal/copytrade.shtml.

Intel, Intel logo, Intel Inside, Intel Inside logo, Intel Centrino, Intel Centrino logo, Celeron, Intel Xeon, Intel SpeedStep, Itanium, and Pentium are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.Linux is a registered trademark of Linus Torvalds in the United States, other countries, or both.Microsoft, Windows, Windows NT, and the Windows logo are trademarks of Microsoft Corporation in the United States, other countries, or both.UNIX is a registered trademark of The Open Group in the United States and other countries.Java and all Java-based trademarks are trademarks of Sun Microsystems, Inc. in the United States, other countries, or both.Other company, product, or service names may be trademarks or service marks of others.

Information is provided "AS IS" without warranty of any kind.

The customer examples described are presented as illustrations of how those customers have used IBM products and the results they may have achieved. Actual environmental costs and performance characteristics may vary by customer.

Information concerning non-IBM products was obtained from a supplier of these products, published announcement material, or other publicly available sources and does not constitute an endorsement of such products by IBM. Sources for non-IBM list prices and performance numbers are taken from publicly available information, including vendor announcements and vendor worldwide homepages. IBM has not tested these products and cannot confirm the accuracy of performance, capability, or any other claims related to non-IBM products. Questions on the capability of non-IBM products should be addressed to the supplier of those products.

All statements regarding IBM future direction and intent are subject to change or withdrawal without notice, and represent goals and objectives only.

Some information addresses anticipated future capabilities. Such information is not intended as a definitive statement of a commitment to specific levels of performance, function or delivery schedules with respect to any future products. Such commitments are only made in IBM product announcements. The information is presented here to communicate IBM's current investment and development activities as a good faith effort to help with our customers' future planning.

Performance is based on measurements and projections using standard IBM benchmarks in a controlled environment. The actual throughput or performance that any user will experience will vary depending upon considerations such as the amount of multiprogramming in the user's job stream, the I/O configuration, the storage configuration, and the workload processed. Therefore, no assurance can be given that an individual user will achieve throughput or performance improvements equivalent to the ratios stated here.

Photographs shown may be engineering prototypes. Changes may be incorporated in production models.

Trademarks and Disclaimers

IBM TSM User Forum 2009

31