iconic wall collection - techo-bloc

5
175 techo-bloc.com WALLS & PILARS PALLET OVERVIEW - PANELS PALLET OVERVIEW - CORNERS COMPATIBLE CAPS See page 141 for product compatibility. Klean-Bloc technology will be available Spring 2021. See page 22. Product is available in Natural Stone while quantities last. NOTES See page 136 to 157 for more technical information. ICONIC FASCIA WALL COLLECTION Specifications per pallet Imperial Metric FASCIA Cubing 45 units 45 units 47.95 ft 2 4.46 m 2 97.44 lin. ft 29.70 lin. m Approx. Weight 1 390 lbs 630 kg Number of rows 3 Coverage per row 15.98 ft 2 1.49 m 2 Linear coverage per row 32.48 lin. ft 9.90 lin. m L2 H D L1 Unit dimensions in mm Units /pallet A Height 5 7/8 150 45 units Depth 2 3/4 70 Length 26 660 Specifications per pallet Imperial Metric CORNER Cubing 24 units 24 units Approx. Weight 700 lbs 318 kg Number of rows 1 Pillar height 35 7/16 in 900 mm L2 H D L1 Unit dimensions in mm Units /pallet A Height 5 7/8 150 12 units Depth 2 3/4 70 Length 23 1/4 590 L2 H D L1 Unit dimensions in mm Units /pallet B Height 5 7/8 150 12 units Depth 2 3/4 70 Length 23 1/4 590 LEFT UNIT RIGHT UNIT Rock Garden Brown Victoria Riviera Onyx Black DESCRIPTION : Fascia Panel & Corner TEXTURE : Klean-Bloc Natural Stone (available Spring 2021) Natural Stone (while quantities last)

Upload: others

Post on 07-Feb-2022

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ICONIC WALL COLLECTION - Techo-Bloc

175

tech

o-bl

oc.c

om

WALLS &

PILARS

PALLET OVERVIEW - PANELS

www.techo-bloc.com

September, 2019

TS-PAL-ICONIC-1

ICONICStandard

PALLET OVERVIEW

PALLET OVERVIEW - CORNERS

www.techo-bloc.com

September, 2019

TS-PAL-ICONIC-1

ICONICCorner

PALLET OVERVIEW

COMPATIBLE CAPSSee page 141 for product compatibility.

Klean-Bloc technology will be available Spring 2021. See page 22.

Product is available in Natural Stone while quantities last.

NOTESSee page 136 to 157 for more technical information.

ICONIC FASCIA WALL COLLECTION

Iconic Fascia Wall collection

Specifications per pallet Imperial Metric

FASC

IA

Cubing

45 units 45 units

47.95 ft2 4.46 m2

97.44 lin. ft 29.70 lin. m

Approx. Weight 1 390 lbs 630 kg

Number of rows 3

Coverage per row 15.98 ft2 1.49 m2

Linear coverage per row 32.48 lin. ft 9.90 lin. m

L2

HDL1

Unit dimensions in mm Units /palletA Height 5 7/8 150 45 units

Depth 2 3/4 70Length 26 660

Specifications per pallet Imperial Metric

CORN

ER Cubing 24 units 24 units

Approx. Weight 700 lbs 318 kg

Number of rows 1

Pillar height 35 7/16 in 900 mm

L2

HDL1

Unit dimensions in mm Units /palletA Height 5 7/8 150 12 units

Depth 2 3/4 70Length 23 1/4 590

L2

HDL1

Unit dimensions in mm Units /palletB Height 5 7/8 150 12 units

Depth 2 3/4 70Length 23 1/4 590

LEFT UNIT

RIGHT UNIT

Rock Garden Brown Victoria Riviera Onyx Black

DESCRIPTION : Fascia Panel & Corner TEXTURE : Klean-Bloc Natural Stone (available Spring 2021) Natural Stone (while quantities last)

Page 2: ICONIC WALL COLLECTION - Techo-Bloc

INSTALLATION GUIDE

177

tech

o-bl

oc.c

om

WALLS &

PILARS

Installation guides

FREESTANDING WALL

FREESTANDING WALL - 90° CORNER

GRAVITY RETAINING WALL

FASCIAFREESTANDING WALL

www.techo-bloc.com

Sep / 2019

TS-SP-FASCIA-WF-EN-1

A

B

F

G

D

E

C

NOTE : THE PATTERNS ON THE PANELS ARE VARIABLE.

TEXTURED PANELWITH SIMULATEDJOINTS

H

I

A. TECHO-BLOC CAP UNIT SECURED TO CORE AND PANEL BELOW WITHCONCRETE ADHESIVE

B. STRUCTURAL BLOCK DOUBLE-SIDED UNITC. PANEL UNITD. 29 1/2'' (750 mm) MAX.E. EMBEDMENT DEPTH 6" (150 mm) MIN.F. GEOTEXTILEG. COMPACTED GRANULAR BASE 6" (150 mm) MIN. THICKNESS

ACCORDING TO PROJECT SPECIFICATIONSH. CONCRETE ADHESIVEI. HDPE HORIZONTAL KEYJ. BASE UNIT

J

FASCIAGRAVITY RETAINING WALL

D

H

I

K

L

M

J

N

GRAVITY WALL DETAIL

A. TECHO-BLOC CAP UNIT SECURED TO UNIT BELOW WITH CONCRETE ADHESIVE

B. STRUCTURAL BLOCK SINGLE SIDED UNIT

C. PANEL UNIT

D. WALL INCLINATION (5.3°)

E. HDPE HORIZONTAL KEY

F. EXPOSED HEIGHT

G. EMBEDMENT DEPTH

H. TOP SOIL

I. LOW PERMEABILITY SOIL

J. 3/4” (20 mm) CLEAN STONE

14" (350mm) THICK MIN.K. RETAINED SOIL

L. GEOTEXTILE

M. PERFORATED DRAIN

N. LEVELING PAD

O. FOUNDATION SOIL

P. CONCRETE ADHESIVE

Q. BASE UNIT

B

E

A

F

G

C

O

P

www.techo-bloc.com TS-SP-FASCIA-WR-EN-4

Q

FASCIAFREESTANDING WALL 90° CORNER

www.techo-bloc.com

Sep / 2019

TS-SP-FASCIA-WF-EN-2

ODD ROW

EVEN ROW

STRUCTURALBLOCK DOUBLESIDED UNIT

LEFT PANEL

RIGHT PANEL

REGULAR PANEL

REGULAR PANEL

TEXTURED PANELWITH SIMULATEDJOINTS

TEXTURED PANEL WITHSIMULATED JOINTS

STRUCTURALBLOCK DOUBLESIDED UNIT CUT /SPLITTED IN HALF

STRUCTURALBLOCK DOUBLESIDED UNITSTRUCTURAL

BLOCK DOUBLESIDED UNIT CUT/SPLITTED IN HALF

1. ALTERNATE ODD AND EVEN ROWS.2. STAGGER STRUCTURAL BLOCKS JOINTS FROM ONE ROW TO THE NEXT.3. GLUE ALL STRUCTURAL BLOCKS AT EACH ROW WITH CONCRETE ADHESIVE.4. APPLY ADHESIVE ON TOP OF UPPERMOST PANEL UNITS TO FIX CAP UNITS.5. STRUCTURAL BLOCK DOUBLE SIDED UNIT CUT / SPLITTED IN HALF MUST ALWAYS BE PRESENT

AT THE CORNER OF THE WALL.

STRUCTURAL BLOCKDOUBLE SIDED UNIT CUT

CUT LINE

A. TECHO-BLOC CAP UNIT SECURED TO CORE AND PANEL BELOW WITH FLEXLOCK ADHESIVE

B. STRUCTURAL BLOCK DOUBLE-SIDED UNIT

C. PANEL UNIT

D. 29 1/2'' (750 mm) MAX.

E. EMBEDMENT DEPTH 6" (150 mm) MIN.

F. GEOTEXTILE

G. COMPACTED GRANULAR BASE 6" (150 mm) MIN. THICKNESS ACCORDING TO PROJECT SPECIFICATIONS

H. FLEXLOCK ADHESIVE

I. HDPE HORIZONTAL KEY

J. BASE UNIT

A. TECHO-BLOC CAP UNIT SECURED TO UNIT BELOW WITH FLEXLOCK ADHESIVE

B. STRUCTURAL BLOCK SINGLE SIDED UNITC. PANEL UNITD. WALL INCLINATION (5.3°)E. HDPE HORIZONTAL KEYF. EXPOSED HEIGHTG. EMBEDMENT DEPTHH. TOP SOILI. LOW PERMEABILITY SOILJ. 3/4” (20 mm) CLEAN STONE

14" (350mm) THICK MIN.K. RETAINED SOILL. GEOTEXTILEM. PERFORATED DRAINN. LEVELING PADO. FOUNDATION SOILP. FLEXLOCK ADHESIVEQ. BASE UNIT

1. ALTERNATE ODD AND EVEN ROWS.

2. STAGGER STRUCTURAL BLOCKS JOINTS FROM ONE ROW TO THE NEXT.

3. GLUE ALL STRUCTURAL BLOCKS AT EACH ROW WITH FLEXLOCK ADHESIVE.

4. APPLY FLEXLOCK ADHESIVE ON TOP OF UPPERMOST PANEL UNITS TO FIX CAP UNITS.

5. STRUCTURAL BLOCK DOUBLE SIDED UNIT CUT / SPLITTED IN HALF MUST ALWAYS BE PRESENT AT THE CORNER OF THE WALL.

PLEASE REFER TO P.4 FOR THE CORRECT USE AND LIMITATIONS OF PROVIDED TECHNICAL INFORMATION.

Page 3: ICONIC WALL COLLECTION - Techo-Bloc

INSTALLATION GUIDE

178

tech

o-bl

oc.c

omW

ALLS

& P

ILAR

S

FREESTANDING END OF A STRAIGHT WALL (OPTION 1)

FREESTANDING END OF A STRAIGHT WALL (OPTION 2)

FASCIAFREESTANDING END OF A STRAIGHT WALL

(OPTION 1)

www.techo-bloc.com

Sep / 2019

TS-SP-FASCIA-WF-EN-3.1

ODD ROW

EVEN ROW

LEFT PANEL

RIGHT PANEL

REGULAR PANEL

REGULAR PANEL

TEXTURED PANEL WITHSIMULATED JOINTS

RIGHT PANELCUT

LEFT PANELCUT

FLEXLOCKADHESIVE

FLEXLOCKADHESIVE

STRUCTURAL BLOCKDOUBLE SIDED UNIT(WITH ONE TAILPIECE CUT)

STRUCTURALBLOCK DOUBLESIDED UNIT

STRUCTURAL BLOCKDOUBLE SIDED UNITCUT/ SPLITTED IN HALF

STRUCTURALBLOCK DOUBLESIDED UNIT

NOTES:1. ALTERNATE ODD AND EVEN ROWS.2. STAGGER STRUCTURAL BLOCKS JOINTS

FROM ONE ROW TO THE NEXT.3. GLUE ALL STRUCTURAL BLOCKS AT EACH

ROW WITH FLEXLOCK ADHESIVE.4. APPLY FLEXLOCK ADHESIVE ON TOP

OF UPPERMOST PANEL UNITS TO FIX CAP UNITS.

FASCIAFREESTANDING END OF A STRAIGHT WALL

(OPTION 2)

www.techo-bloc.com

Sep / 2019

TS-SP-FASCIA-WF-EN-3.2

ODD ROW

EVEN ROW

LEFT PANEL

REGULAR PANEL

REGULAR PANEL

TEXTURED PANEL WITHSIMULATED JOINTS

STRUCTURALBLOCK DOUBLESIDED UNIT

STRUCTURAL BLOCKDOUBLE SIDED UNIT(WITH ONE TAILPIECE CUT)

REGULAR PANELCUT

REGULAR PANELCUT

LEFT PANEL

RIGHT PANEL

FLEXLOCKADHESIVE

FLEXLOCKADHESIVE

STRUCTURALBLOCK DOUBLESIDED UNIT

RIGHT PANELSTRUCTURAL BLOCKDOUBLE SIDED UNITCUT/ SPLITTED IN HALF

NOTES:1. ALTERNATE ODD AND EVEN ROWS.2. STAGGER STRUCTURAL BLOCKS JOINTS

FROM ONE ROW TO THE NEXT.3. GLUE ALL STRUCTURAL BLOCKS AT EACH

ROW WITH FLEXLOCK ADHESIVE.4. APPLY FLEXLOCK ADHESIVE ON TOP

OF UPPERMOST PANEL UNITS TO FIX CAP UNITS.

FASCIAFREESTANDING END OF A STRAIGHT WALL

(OPTION 1)

www.techo-bloc.com

Sep / 2019

TS-SP-FASCIA-WF-EN-3.1

ODD ROW

EVEN ROW

LEFT PANEL

RIGHT PANEL

REGULAR PANEL

REGULAR PANEL

TEXTURED PANEL WITHSIMULATED JOINTS

RIGHT PANELCUT

LEFT PANELCUT

FLEXLOCKADHESIVE

FLEXLOCKADHESIVE

STRUCTURAL BLOCKDOUBLE SIDED UNIT(WITH ONE TAILPIECE CUT)

STRUCTURALBLOCK DOUBLESIDED UNIT

STRUCTURAL BLOCKDOUBLE SIDED UNITCUT/ SPLITTED IN HALF

STRUCTURALBLOCK DOUBLESIDED UNIT

NOTES:1. ALTERNATE ODD AND EVEN ROWS.2. STAGGER STRUCTURAL BLOCKS JOINTS

FROM ONE ROW TO THE NEXT.3. GLUE ALL STRUCTURAL BLOCKS AT EACH

ROW WITH FLEXLOCK ADHESIVE.4. APPLY FLEXLOCK ADHESIVE ON TOP

OF UPPERMOST PANEL UNITS TO FIX CAP UNITS.

FASCIAFREESTANDING END OF A STRAIGHT WALL

(OPTION 2)

www.techo-bloc.com

Sep / 2019

TS-SP-FASCIA-WF-EN-3.2

ODD ROW

EVEN ROW

LEFT PANEL

REGULAR PANEL

REGULAR PANEL

TEXTURED PANEL WITHSIMULATED JOINTS

STRUCTURALBLOCK DOUBLESIDED UNIT

STRUCTURAL BLOCKDOUBLE SIDED UNIT(WITH ONE TAILPIECE CUT)

REGULAR PANELCUT

REGULAR PANELCUT

LEFT PANEL

RIGHT PANEL

FLEXLOCKADHESIVE

FLEXLOCKADHESIVE

STRUCTURALBLOCK DOUBLESIDED UNIT

RIGHT PANELSTRUCTURAL BLOCKDOUBLE SIDED UNITCUT/ SPLITTED IN HALF

NOTES:1. ALTERNATE ODD AND EVEN ROWS.2. STAGGER STRUCTURAL BLOCKS JOINTS

FROM ONE ROW TO THE NEXT.3. GLUE ALL STRUCTURAL BLOCKS AT EACH

ROW WITH FLEXLOCK ADHESIVE.4. APPLY FLEXLOCK ADHESIVE ON TOP

OF UPPERMOST PANEL UNITS TO FIX CAP UNITS.

FASCIAFREESTANDING END OF A STRAIGHT WALL

(OPTION 1)

www.techo-bloc.com

Sep / 2019

TS-SP-FASCIA-WF-EN-3.1

ODD ROW

EVEN ROW

LEFT PANEL

RIGHT PANEL

REGULAR PANEL

REGULAR PANEL

TEXTURED PANEL WITHSIMULATED JOINTS

RIGHT PANELCUT

LEFT PANELCUT

FLEXLOCKADHESIVE

FLEXLOCKADHESIVE

STRUCTURAL BLOCKDOUBLE SIDED UNIT(WITH ONE TAILPIECE CUT)

STRUCTURALBLOCK DOUBLESIDED UNIT

STRUCTURAL BLOCKDOUBLE SIDED UNITCUT/ SPLITTED IN HALF

STRUCTURALBLOCK DOUBLESIDED UNIT

NOTES:1. ALTERNATE ODD AND EVEN ROWS.2. STAGGER STRUCTURAL BLOCKS JOINTS

FROM ONE ROW TO THE NEXT.3. GLUE ALL STRUCTURAL BLOCKS AT EACH

ROW WITH FLEXLOCK ADHESIVE.4. APPLY FLEXLOCK ADHESIVE ON TOP

OF UPPERMOST PANEL UNITS TO FIX CAP UNITS.

FASCIAFREESTANDING END OF A STRAIGHT WALL

(OPTION 2)

www.techo-bloc.com

Sep / 2019

TS-SP-FASCIA-WF-EN-3.2

ODD ROW

EVEN ROW

LEFT PANEL

REGULAR PANEL

REGULAR PANEL

TEXTURED PANEL WITHSIMULATED JOINTS

STRUCTURALBLOCK DOUBLESIDED UNIT

STRUCTURAL BLOCKDOUBLE SIDED UNIT(WITH ONE TAILPIECE CUT)

REGULAR PANELCUT

REGULAR PANELCUT

LEFT PANEL

RIGHT PANEL

FLEXLOCKADHESIVE

FLEXLOCKADHESIVE

STRUCTURALBLOCK DOUBLESIDED UNIT

RIGHT PANELSTRUCTURAL BLOCKDOUBLE SIDED UNITCUT/ SPLITTED IN HALF

NOTES:1. ALTERNATE ODD AND EVEN ROWS.2. STAGGER STRUCTURAL BLOCKS JOINTS

FROM ONE ROW TO THE NEXT.3. GLUE ALL STRUCTURAL BLOCKS AT EACH

ROW WITH FLEXLOCK ADHESIVE.4. APPLY FLEXLOCK ADHESIVE ON TOP

OF UPPERMOST PANEL UNITS TO FIX CAP UNITS.

PLEASE REFER TO P.4 FOR THE CORRECT USE AND LIMITATIONS OF PROVIDED TECHNICAL INFORMATION.

Page 4: ICONIC WALL COLLECTION - Techo-Bloc

INSTALLATION GUIDE

179

tech

o-bl

oc.c

om

WALLS &

PILARS

FASCIA PILLAR

www.techo-bloc.com

Sep / 2019

TS-SP-FASCIA-PL-EN-1

ODD ROW

EVEN ROW

STRUCTURAL BLOCKSINGLE SIDED UNIT

STRUCTURAL BLOCKSINGLE SIDED UNITCUT / SPLITTED INHALF

RIGHT PANEL

LEFT PANEL

A

B

FG

D

E

C

TEXTURED PANEL WITHSIMULATED JOINTS

STRUCTURAL BLOCKSINGLE SIDED UNIT

STRUCTURAL BLOCKSINGLE SIDED UNITCUT / SPLITTED INHALF

STRUCTURAL BLOCK SINGLE SIDED UNIT CUT / SPLITTED IN HALF

CUT LINE

NOTE: SECURE EACH ROW WITHFLEXLOCK ADHESIVE.

A. PILLAR CAP UNIT SECURED TO CORE AND PANEL BELOW WITH FLEXLOCK ADHESIVE

B. RIGHT PANELC. LEFT PANELD. 35 7/16'' (900 mm) MAX HEIGHTE. EMBEDMENT DEPTH 6" (150 mm) MIN.F. GEOTEXTILEG. COMPACTED GRANULAR BASE 6"

(150 mm) MIN.THICKNESS ACCORDING TO PROJECT SPECIFICATIONS.

26"(660 mm)

26"(660 mm)

A. PILLAR CAP UNIT SECURED TO CORE AND PANEL BELOW WITH FLEXLOCK ADHESIVE

B. RIGHT PANEL

C. LEFT PANEL

D. 35 7/16'' (900 mm) MAX HEIGHT

E. EMBEDMENT DEPTH 6" (150 mm) MIN.

F. GEOTEXTILE

G. COMPACTED GRANULAR BASE 6" (150 mm) MIN.THICKNESS ACCORDING TO PROJECT SPECIFICATIONS.

For all possible combinations of pillars and caps, please refer to the correspondence table on page 141

PILLARS - FASCIA WALL COLLECTION

PLEASE REFER TO P.4 FOR THE CORRECT USE AND LIMITATIONS OF PROVIDED TECHNICAL INFORMATION.

Page 5: ICONIC WALL COLLECTION - Techo-Bloc

INSTALLATION GUIDE

180

tech

o-bl

oc.c

omW

ALLS

& P

ILAR

S

STEPS - FASCIA WALL COLLECTION

www.techo-bloc.com

June 2020

TS-SP-FASCIA-WST-EN-1

1-877-832-4625www.techo-bloc.com

FASCIA RIGHTPANEL

FASCIA LEFTPANEL

FASCIAREGULAR PANEL

TEXTURED PANEL WITHSIMULATED JOINTS

FASCIA REGULARPANEL CUT

FASCIA STRUCTURALBLOCK SINGLE-SIDED

UNIT CUT

CAP UNIT

FASCIA STRUCTURALBLOCK SINGLE-SIDED UNIT

FLEXLOCKADHESIVE

CAP UNIT

VARIABLE

5 7/8"(150 mm)

FASCIA PANELUNIT

5 7/8"(150 mm)

FASCIA BASEUNIT

FASCIASTEPS

FASCIA STRUCTURALBLOCK SINGLE-SIDED UNIT

FLEXLOCKADHESIVE

PLEASE REFER TO P.4 FOR THE CORRECT USE AND LIMITATIONS OF PROVIDED TECHNICAL INFORMATION.