id5101 qig 2011-0721

4
1 800-0000007-00-00 Package Contents Rear Panel & GPIO Connectors NOTE: To avoid electrical shock, we strongly suggest that connecting AC power to ID5101 after ID5101 has installed on the wall. Due to the view angle of the camera is limited, therefore the installation position for Video Indoor Station is crucial. In order to get a better view, the view angle of this door phone should be around 105. Also the height of the lens position is suggested between 155 cm to 165 cm according to building conditions. Installing Video Indoor Station Package Contents Rear Panel and Connectors Installing Procedures 1. Screw the Back Plate on the wall. Please pull out the AC wires and Ethernet cable pass through the back plate. Then, connect them with the Video Indoor Station after securing the Back Plate on the wall. If necessary, please connect the Earth wire to the screw as diagram below. For more GPIO application, please refer to Safety/Security Application in next page 2. Connect the AC (Universal 100~240VAC) wires and Ethernet cable. Plug the AC cable connector of ID5101 to Power-Connecting connector, and connect Ethernet cable to ID5101 as diagram below. Be careful when you are connecting the AC wires, please check the AC condition and turn off the general power switch before you start to connect the wires. 3. Screw the Video Indoor Station with Back Plate. Before connecting to Safety and Security Devices GPIO connectors and I/O Pin Assignment and Wire Color There are three GPIO connectors on the rear panel of your Video Indoor Station. These GPIO connectors are used to connect with Safety and Security devices. Before you begin to connect other devices to the ID5101, the I/O wires and their colors for GPIO connectors are illustrated as pictures below. GPIO connectors and I/O Pin Assignment and Wire Color These items are included in your Video Indoor Station package. Check this list before installation to ensure that you have received all items. 1. Video Indoor Station 2. Back Plate 3. Wall mounted screw pack 4. Screw Pack (2 pieces of M4 x 10 mm) 5. Screw for Earth Wire 6. Wrench 7. H type Terminal Connector for Power Wire (2 pieces) 8. Adapter 9. I/O Cable (3 pieces) 10. Relay Board (2 pieces) (Accessories are put in the paper tube of box) Please contact your dealer immediately if any item(s) is missing. Installation Example Please reserve the space for junction wiring in the wall, you may refer to the embedded box dimension as diagram below. After connecting the wires and cables properly, then screw the 2 screws that come with the package into the front panel. Please double check all the installation procedures again, then you may power on the general power switch to start the configuration procedures.

Upload: z-waver

Post on 09-Mar-2016

230 views

Category:

Documents


1 download

DESCRIPTION

 

TRANSCRIPT

Page 1: ID5101 QIG 2011-0721

1 800-0000007-00-00

Package Contents

Rear Panel & GPIO Connectors

NOTE: To avoid electrical shock, we strongly suggest that connecting AC power to

ID5101 after ID5101 has installed on the wall.

Due to the view angle of the camera is limited, therefore the installation position for

Video Indoor Station is crucial. In order to get a better view, the view angle of this door

phone should be around 105. Also the height of the lens position is suggested between

155 cm to 165 cm according to building conditions.

Installing Video Indoor Station

Package Contents

Rear Panel and Connectors

Installing Procedures

1. Screw the Back Plate on the wall.

Please pull out the AC wires and Ethernet cable pass through the back plate. Then,

connect them with the Video Indoor Station after securing the Back Plate on the wall.

If necessary, please connect the Earth wire to the screw as diagram below.

For more GPIO application, please refer to Safety/Security Application in next page

2. Connect the AC (Universal 100~240VAC) wires and Ethernet cable.

Plug the AC cable connector of ID5101 to Power-Connecting connector, and connect Ethernet cable to ID5101 as diagram below. Be careful when you are connecting the AC wires, please check the AC condition and turn off the general power switch before you start to connect the wires.

3. Screw the Video Indoor Station with Back Plate.

Before connecting to Safety and Security Devices

GPIO connectors and I/O Pin Assignment and Wire Color

There are three GPIO connectors on the rear panel of your Video Indoor Station.

These GPIO connectors are used to connect with Safety and Security devices.

Before you begin to connect other devices to the ID5101, the I/O wires and their

colors for GPIO connectors are illustrated as pictures below.

GPIO connectors and I/O Pin Assignment and Wire Color

These items are included in your Video Indoor Station

package. Check this list before installation to ensure

that you have received all items.

1. Video Indoor Station

2. Back Plate

3. Wall mounted screw pack

4. Screw Pack (2 pieces of M4 x 10 mm)

5. Screw for Earth Wire

6. Wrench

7. H type Terminal Connector for Power Wire (2 pieces)

8. Adapter

9. I/O Cable (3 pieces)

10. Relay Board (2 pieces)

(Accessories are put in the paper tube of box) Please contact your dealer immediately if any item(s) is missing.

Installation Example

Please reserve the space for junction wiring in the wall, you may refer to the embedded box dimension as diagram below.

After connecting the wires and cables properly,

then screw the 2 screws that come with the

package into the front panel. Please double check

all the installation procedures again, then you may

power on the general power switch to start the

configuration procedures.

Page 2: ID5101 QIG 2011-0721

2 800-0000007-00-00

The ID5101, Video Indoor Station, provides 8 Input ports and 4 Output port for your house

to set up Home Safety and Security; you may refer the following examples for each

application.

Please connect the adapter which comes with the package to the AC line as below and

then connect your end devices according to your requirement.

The illustration (diagram) shows you how to use the first GPIO connector and wire to

connect Adapter and two Relay Boards for Lighting Control.

The illustration (diagram) shows you how to use the first GPIO connector and wire to

connect AC power, Adapter and Relay Board for ALARM device.

Both diagram and photo of Magnetic Switch installation show you how to use the second

GPIO connector to connect with Magnetic Switches, and you can connect up to four

magnetic switches accordingly based on the diagram or photo.

The status of the following safety devices will be shown on the main screen. The following

diagrams show you how to use 3rd GPIO connector to connect CO Sensor, Emergency

Button, and Gas Detector.

Magnetic Switches

IO Circuit and Application

LIGHTING

ALARM

CO Detector, Emergency Button and Gas Detector

NOTE:

The second GPIO

connector is used to

connect up to four

Magnetic Switches.

NOTE:

Please use wire

tape to seal

unused wire to

isolate the wire.

Connect to AC line and Adapter

Wire connection for Lighting

Wire connection for Alarm

Wire connection for Alarm

Wire connection for MS (Magnetic Switches)

Page 3: ID5101 QIG 2011-0721

3 800-0000007-00-00

NOTE: The 3rd GPIO connector is used to connect CO Sensor, Emergency Button, and

Gas Detector.

There are two ways to configure ID5101. One is “Configure via Web UI”, the other is

“Configure on ID5101”.

This section describes how to configure your ID5101 with Web User Interface. This UI

also provide remote management capability to service provider.

NOTE: After Log in Web UI, Language on the first page allows you to select language “English” or “Traditional Chinese” and let the language be displayed on your ID5101 GUI.

Item Description

MAC Address This is a quasi-unique identifier attached to most network adapters.

IP Type The default value is DHCP Client. There are three options: DHCP Client, Static IP and PPPoE.

A. DHCP Client: The system will automatically assign you an IP address.

B. Static IP: you have to input IP address, Subnet Mask, Default Gateway, Primary DNS and Secondary DNS data.

C. PPPoE: This allows you to set Internet connection with User Name and Password.

Save Click this button to save your setting.

Item Description

Authentication

Display Name This name will show on the IP phone of called parties. You

can fill in the preferred name here.

For example, 807

User Number You may fill in the phone number here, normally it is provided

by service provider. To work with IP PBX, you may fill in

extension number. For example, 807

Account ID You may fill in your account name of SIP service in this field.

For example, 807

Account

Password

You may fill in the password of your SIP service account.

For example, 807

SIP Proxy Server

Service You may select “Enable” or “Disable” the SIP Proxy Server in

the dropdown menu.

NOTE: For Peer-to-Peer mode, user needs to select

Disable in the dropdown menu.

IP Address You may fill in the IP address of SIP Proxy Server in this field.

SIP Registrar Server

IP Address You may fill in the IP address of SIP Registrar Server here.

Registration

Expire Time

The default is 3600 seconds.

Protocol You may select network communication protocol of the SIP

service here. There are 2 options: UDP and TCP.

Default setting is UDP protocol.

Hold Version This setting is configured differently depending on which SIP

proxy server is being connected. The SIP proxy server may

support generally two type of call hold, RFC2543 and

RFC3264.

Session Timer You can set the session timer here. The range is from 0 to

1800 seconds.

Default is 0 second.

Media Timer This setting allows your phone to force release automatically

a conversational call when your phone doesn't receive any

media packets from the remote side during a period of time. If

you want to disable this feature, please fill in "0" sec.

SIP TOS You may enable Tag-of-Service of SIP protocol here.

RTP TOS You may enable Tag-of-Service of RTP protocol here.

Save Click this button to save your setting.

This webpage is used to configure Safety and Security devices.

There are 8 Input ports (DI1~DI8) and 4 Output ports (DO1~DO4) available on

ID5101 GPIO module.

Moreover, DI1-DI4 are for MS (Magnetic Sensors), DI5-DI8 are for CO sensor,

Emergency Button, and Gas detector (DI8 is reserved).

DO1-DO3 are for Lighting, Lighting, Alarm. (DO4 is reserved).

Configure via Web UI

NOTE 1: To obtain IP address of your

ID5101.

Select Setting soft-function key ����

Network Setting on your ID5101

(with password: default:1234) ����

IP Address

And you will find IP address of the

ID5101 on the network.

Input IP address of your ID5101

NOTE 2: The default ID and

password for system login

are “admin” and “admin”.

Network Setting

SIP Setting

Safety & Security – Device setting

Wire connection for CO, Gas detector, and Emergency Button

Login ID5101 Web UI

SIP Setting page

Page 4: ID5101 QIG 2011-0721

4 800-0000007-00-00

ITEM Description

Device Name In the drop-down menu, select the device name that your

ID5101’s GPIO port is connected to.

Triggered by For 8 Input ports only, user may select “Positive” or

“Negative”.

NOTE: This means user can define the light status (Green

or Red) on your ID5101 Safety Sub-menu.

En/Disable Select “Enable” or “Disable”

User may select “Disable” when the ID5101’s GPIO port is

not connected to any device.

NOTE: If user doesn’t install some safety device, we suggest SI select “Disable”

so that the safety device will be displayed as gray light on ID5101.

This section describes how to set up your Video Indoor Station. You may press Setting

soft-function key to enter this Setting page. There are 8 major items for configuration:

You may use [ � ] and [ � ] keys to select preferred item, and then press Enter key [ ���� ]

or press Enter soft-function key to take further actions.

NOTE: 1. Network Setting, SIP Setting, Stream Setting, and Service Setting are

protected by password. (Default password: 1234)

2. This setting password is different from Security password.

This Network Setting allows you to set

up the important parameters of

network connection, and it is protected

by password.

NOTE: You need to enter password to

enter “Network Setting”. Default

password is “1234”. You may

change password by using Chg

Password soft-function key.

ITEM Description

Net Type This item allows you to select type of IP address of this

device. There are 3 options DHCP, Static IP and PPPoE, the

default is DCHP.

� DHCP - If you wish to connect this device to an exist

network and get dynamic IP address from the DHCP server,

please select this one. You will see all other items in this

mode are grayed out. In most of cases, DHCP Client is used

for connecting LAN (Local-Area-Network).

� Static IP - If you wish to use Static IP address to

connect to network, you may select this one. You may get

Static IP when you applying SIP service from carriers or

operators. You will see last 2 items for PPPoE are grayed

out.

� PPPoE - This selection is for connecting ADSL modem

directly. Your phone will trigger ADSL model to connect to

Internet automatically when you are dialing phone number.

IP Address You may fill in IP address here if Static IP is selected.

Subnet Mask You may fill in Subnet Mask address here if Static IP is

selected.

Default

Gateway

You may fill in default gateway address here if Static IP is

selected.

Primary DNS You may fill in primary DNS server address here if Static IP is

selected.

Secondary DNS You may fill in secondary DNS server address here if Static

IP is selected.

PPPoE Account You may fill in PPPoE account ID or name here if PPPoE is

selected in IP type selection.

PPPoE

Password

You may fill in PPPoE account password here if PPPoE is

selected in IP type selection.

Web UI This item allows you enable or disable the

Web-User-Interface HTTP service. Web UI will be not

available if disabled.

ICMS IP The IP address of ICMS (Intelligent Community Management

Server).

NOTE: Your ID5101 needs to be connected to AmRoad

ICMS system.

ICMS Port The IP port number of ICMS (Intelligent Community

Management Server).

NOTE: Your ID5101 needs to be connected to AmRoad

ICMS system.

This setting allows you to se up necessary parameters of SIP services and it is password

protected. Default password is “1234”. You may change password by using Chg

Password soft-function key.

ITEM Description

Phone Number The phone number of your ID5101. Normally it is provided by

service provider. You can also set an extension number here

if connecting to an IP PBX.

Display Name Initial of Display Name. This name will show on the IP phone

of called parties. You may fill in the preferred name here.

Account You may fill in your account name of SIP service here.

Password You may fill in the password of your SIP service account

here.

Mode This item allows you to select the working model of SIP

service. Select “Server Mode” mode if this phone is

connected to a SIP server or IP PBX. Default setting is

“Peer-to-Peer Mode”.

Protocol You may select the correct low level communication protocol

here. There are 2 options: UDP and TCP. You have to

confirm which one the service is using from your service

provider. Default setting is UDP.

SIP Proxy You may fill in IP address or domain name of the SIP Proxy

Server here.

SIP Registrar You may fill in IP address or domain name of SIP Registrar

Server here.

SIP Expire Initial of Registration Time. This item is a parameter of SIP

service. You may fill in the effective registration period of SIP

service here. You have to contact your service provider to

get correct setting. Default setting is 3600 seconds.

SIP Sess Timer Initial of Session Timer. This is a parameter of SIP service.

You may fill in the Session Timer period of SIP service. You

have to contact your service provider to get correct setting.

Default setting is 0 seconds.

NOTE 1: To open the door by pressing the “ # ” keypad on ID5101 Video Indoor Station,

the door must have been installed “Electrical-door Lock”.

NOTE 2: ID5101 RFID Internal Module, ISO 14443A Compliant/ 13.56 MHz RFID Mifare.

NOTE: For more detailed information, the setting of Video Indoor Station and the Web UI

Configuration, please refer to the ID5101 SI Manual.

AmRoad Technology Inc. www.amroad.com.tw

Configure on ID5101

Network Setting

SIP Setting

Device Setting page

Press Setting soft-function key to enter Setting page

The screen after entering Network Setting page

Extra NOTE