ijhrb preview 2012 1
DESCRIPTION
journalTRANSCRIPT
About the CouncilThe Council on Tall Buildings and Urban Habitat, based at the Illinois Institute of
Technology in Chicago, is an international not-for-profit organization supported by
architecture, engineering, planning, development and construction professionals. Founded in 1969, the Council’s mission is to disseminate multi-disciplinary information
on tall buildings and sustainable urban environments, to maximize the international
interaction of professionals involved in creating the built environment, and to make
the latest knowledge available to professionals in a useful form.
The CTBUH disseminates its findings, and facilitates business exchange, through: the
publication of books, monographs, proceedings and reports; the organization of world congresses, international, regional and specialty conferences and workshops; the
maintaining of an extensive website and tall building databases of built, under
construction and proposed buildings; the distribution of a monthly international tall
building e-newsletter; the maintaining of an international resource center; the bestowing of annual awards for design and construction
excellence and individual lifetime achievement; the management of special task forces/working groups; the hosting of
technical forums; and the publication of the CTBUH Journal, a professional journal containing refereed papers written by
researchers, scholars and practicing professionals.
The Council is the arbiter of the criteria upon which tall building height is measured, and thus the title of "The World’s Tallest Building" determined. CTBUH is the world’s leading
body dedicated to the field of tall buildings and urban habitat and the recognized
international source for information in these fields.
CTBUH Journal
About the CouncilThe Council on Tall Buildings and Urban Habitat, based at
the Illinois Institute of Technology in Chicago, is an
international not-for-profit organization supported by
architecture, engineering, planning, development and
construction professionals. Founded in 1969, the
Council’s mission is to disseminate multi-disciplinary
information on tall buildings and sustainable urban
environments, to maximize the international interaction
of professionals involved in creating the built
environment, and to make the latest knowledge
available to professionals in a useful form.
The CTBUH disseminates its findings, and facilitates
business exchange, through: the publication of books,
monographs, proceedings and reports; the organization
of world congresses, international, regional and specialty
conferences and workshops; the maintaining of an
extensive website and tall building databases of built,
under construction and proposed buildings; the
distribution of a monthly international tall building
e-newsletter; the maintaining of an international resource
center; the bestowing of annual awards for design and
construction excellence and individual lifetime
achievement; the management of special task forces/
working groups; the hosting of technical forums; and the
publication of the CTBUH Journal, a professional journal
containing refereed papers written by researchers,
scholars and practicing professionals.
The Council is the arbiter of the criteria upon which tall
building height is measured, and thus the title of "The
World’s Tallest Building" determined. CTBUH is the world’s
leading body dedicated to the field of tall buildings and
urban habitat and the recognized international source for
information in these fields.
Council on Tall Buildings and Urban Habitat Issue Chief Editor: Sang Dae Kim
Volume 1 Number 1 March 2012
Amplitude Dependency of Damping in Buildings and Critical Tip Drift RatioYukio Tamura
Human-Induced Vibrations in BuildingsMichael J. Wesolowsky, Peter A. Irwin, Jon K. Galsworthy, and Andrew K. Bell
Strength Evaluation for Cap Plate on the Node Connection in Circular Steel Tube Digrid SystemSeong-Hui Lee, Jin-Ho Kim, and Sung-Mo Choi
Experimental and Analytical Investigation of Web-transferred Diagrid Node under Seismic ConditionInyong Jeong, Young K. Ju, and Sang Dae Kim
Validating the Structural Behavior and Response of Burj Khalifa: Synopsis of the Full Scale Structural Health Monitoring ProgramsAhmad Abdelrazaq
Parametric Analysis and Design Engine for Tall Building StructuresGoman Ho, Peng Liu, and Michael Liu
Anything Goes?Dennis Poon and Leonard Joseph
CTBU
H
International Journal of High-Rise Buildings
ISSN 2234-7224
Volume 1 Number 1 March 2012
No. 1 2012
INTERN
ATION
AL JO
URN
AL O
F HIG
H-RISE BU
ILDIN
GS VO
LUM
E 1
CTBUH1.0319.indd 1 2012-04-13 오전 9:03:37
Volume 1, Number 1, March 2012
International Journal of
High-Rise Buildingswww.ctbuh.org
1 Amplitude Dependency of Damping in Buildings and Critical Tip Drift Ratio
Yukio Tamura
15 Human-Induced Vibrations in Buildings
Michael J. Wesolowsky, Peter A. Irwin, Jon K. Galsworthy, and Andrew K. Bell
21 Strength Evaluation for Cap Plate on the Node Connection in Circular Steel Tube Diagrid System
Seong-Hui Lee, Jin-Ho Kim, and Sung-Mo Choi
29 Experimental and analytical Investigation of Web-transferred Diagrid Node under Seismic Condition
Inyong JEONG, Young K. JU, and Sang-Dae KIM
37 Validating the Structural Behavior and Response of Burj Khalifa: Synopsis of the Full Scale Structural
Health Monitoring Programs
Ahmad Abdelrazaq
53 Parametric Analysis and Design Engine for Tall Building Structures
Goman Ho, Peng Liu, and Michael Liu
61 Anything Goes?
Dennis Poon and Leonard Joseph
Subscription information
■ Council on Tall Buildings and Urban Habitat
S. R. Crown Hall Illinois Institute of Technology 3360 South State Street Chicago, IL 60616
Phone : +1 (312) 567 3487
Fax : +1 (312) 567 3820
E-mail : [email protected]
■ Korean Council on Tall Buildings and Urban Habitat
#301 Ochang B/D, 208-2 Nonhyeon-dong, Gangnam-gu, Seoul, 135-010, Korea
Phone : +82 (2) 3290 4742
Fax : +82 (2) 921 2439
E-mail : [email protected]
Contents
International Journal of
High-Rise Buildingswww.ctbuh.org
Editor’s Note
The Council on Tall Buildings and Urban Habitat has developed into the world’s most influential and
renowned professional organization on tall buildings since its establishment in 1969. Today it leads the
industry by disseminating the latest information to professionals working on tall building design and
engineering, including the production of design guidelines, and volumes of books and technical papers
contributed by the world’s most experienced experts.
The main outlet for the Council’s work is the CTBUH Journal, which has published for 12 years, including
practical articles on all aspects of tall building design and construction. It has received great response from
around the world and become a valuable resource for the industry.
Now the Council has decided to publish a new journal, the International Journal of High-Rise Buildings
(IJHRB), focusing on pure research content and investigations in tall building design. The IJHRB should
serve as essential compliment to the CTBUH Journal, adding to the Council’s already substantial body of
work. IJHRB will be published four times a year, with a different Chief Editor in charge of each issue.
Although the journal welcomes any papers on tall-building-related topics, we will concentrate on the
followings for the first two years:
- Architectural Planning & Design
- Construction Technology- Energy Savings
- MEP
- Structural Engineering
- Sustainability
I truly hope the IJHRB will energize the tall building industry. Many researchers will be able to present
their work and results through the journal and apply the contents to their everyday practice.
Professionals who wish to contribute their papers to the journal can find the necessary information in the
Overview and Paper Submission Guide at the back of this publication.
Sincerely,
Prof. Sang Dae Kim
Co-Chief Editor
International Journal of
High-Rise Buildingswww.ctbuh.org
International Journal of High-Rise Buildings
March 2012, Vol 1, No 1, 1-13
Amplitude Dependency of Damping in Buildings and Critical Tip
Drift Ratio
Yukio Tamura†
School of Architecture and Wind Engineering, Tokyo Polytechnic University, Atsugi 243-0297, Japan
Abstract
The importance of appropriate use of damping evaluation techniques and points to note for accurate evaluation of damping
are first discussed. Then, the variation of damping ratio with amplitude is discussed, especially in the amplitude range relevant
to wind-resistant design of buildings, i.e. within the elastic limit. The general belief is that damping increases with amplitude,
but it is emphasized that there is no evidence of increasing damping ratio in the very high amplitude range within the elastic
limit of main frames, unless there is damage to secondary members or architectural finishings. The damping ratio rather
decreases with amplitude from a certain tip drift ratio defined as “critical tip drift ratio,” after all friction surfaces between
primary/structural and secondary/non-structural members have been mobilized.
Keywords: Damping, Wind-induced response, Amplitude dependency, Critical tip drift ratio, Damping evaluation technique
1. Introduction
In order to accurately evaluate the responses of build-
ings and structures under wind, earthquake or other exter-
nal excitations, their dynamic properties such as natural
frequencies, mode shapes and damping ratios should be
exactly known. Damping is the most important dynamic
but most uncertain parameter affecting the dynamic
responses of buildings and structures. This uncertainty
significantly reduces the reliability of structural design for
dynamic effects. For example, the C.O.V. of full-scale
data has been estimated at almost 70% (Havilland, 1976).
If the design value of damping ratio is set at 2% based on
the mean value of full-scale data, mean ± σ (standard
deviation) ranges from 0.6% to 3.4% (= 2% ± 1.4%). If
we evaluate wind-induced acceleration responses of a tall
building with almost 5.7 times difference between damp-
ing ratios (= 3.4/0.6), the acceleration responses show 2.4
times difference. Therefore, accurate evaluation of design
damping ratio is a pressing need for tall building design.
Another important suggestion on application of damping
devices can be derived from this fact. If we could assure
additional damping, say 4%, by applying a damping
device, the total damping ratio in the building would
range from 4.6% to 7.4%, i.e., the difference would be
only 1.6 times, and the difference between the resultant
acceleration responses would be only 1.3 times.
Unlike seismic excitations, wind excitations last for a
long period, e.g. a few hours, and induced building
responses are composed of a static component, a quasi-
static component, and a resonant component, as shown in
Fig. 1. If the response level exceeds the elastic limit, the
natural frequency shifts to a lower frequency due to
softening phenomena in the plastic region (Tamura et al.,
2001; Tamura, 2009). This natural frequency shift results
in an increase in the corresponding wind force spectrum,
and can potentially increase the resonant component. The
static component also shows some interesting behaviors
such as a sudden increase in the along-wind direction
(Tsujita et al., 1997; Tamura et al., 2001). There are vari-
ous uncertainties in the characteristics of wind-induced
responses of a building in the plastic region due to the
long-lasting excitation, static components, and softening
phenomena. Therefore, almost all wind loading codes/
standards, e.g. AIJ-RLB (2004) and ISO4354 (2009),
clearly require almost-elastic behavior even for extremely
strong wind conditions such as ultimate limit state design.
Thus, wind-induced responses of buildings are assumed
to be almost-elastic, and the gust loading factor and the
equivalent static wind loads in codes/standards are essen-
tially based on linear/elastic structural behavior (ISO
4354, 2009). In this paper, the dynamic behaviors of main
frames of buildings are also assumed to be in the elastic
region.
As there is no theoretical method for estimating
damping in buildings, it is estimated from full-scale data,
which shows significant dispersion for various reasons.
There are many potential causes of dispersion of full-
scale damping data as follows:
- Soil types
†Corresponding author : Yukio TamuraTel: +81 (0) 46 242 9547; Fax: +81 (0) 46 242 9547E-mail: [email protected]
International Journal of
High-Rise Buildingswww.ctbuh.org
International Journal of High-Rise Buildings
March 2012, Vol 1, No 1, 15-19
Human-Induced Vibrations in Buildings
Michael J. Wesolowsky, Peter A. Irwin, Jon K. Galsworthy†, and Andrew K. Bell
Rowan Williams Davies & Irwin, Inc., Guelph, Ontario, Canada
Abstract
Occupant footfalls are often the most critical source of floor vibration on upper floors of buildings. Floor motions can degradethe performance of imaging equipment, disrupt sensitive research equipment, and cause discomfort for the occupants. It isessential that low-vibration environments be provided for functionality of sensitive spaces on floors above grade. This requiresa sufficiently stiff and massive floor structure that effectively resists the forces exerted from user traffic.
Over the past 25 years, generic vibration limits have been developed, which provide frequency dependent sensitivities forwide classes of equipment, and are used extensively in lab design for healthcare and research facilities. The same basis for thesecurves can be used to quantify acceptable limits of vibration for human comfort, depending on the intended occupancy of thespace. When available, manufacturer's vibration criteria for sensitive equipment are expressed in units of acceleration, velocityor displacement and can be specified as zero-to-peak, peak-to-peak, or root-mean-square (rms) with varying frequency rangesand resolutions.
Several approaches to prediction of floor vibrations are currently applied in practice. Each method is traceable to fundamentalstructural dynamics, differing only in the level of complexity assumed for the system response, and the required informationfor use as model inputs. Three commonly used models are described, as well as key features they possess that make themattractive to use for various applications.
A case study is presented of a tall building which has fitness areas on two of the upper floors. The analysis predicted thatthe motions experienced would be within the given criteria, but showed that if the floor had been more flexible, the potentialexists for a locked-in resonance response which could have been felt over large portions of the building.
Keywords: Human-induced vibrations, Sensitive equipment, Occupant comfort, Building performance, Vibration criteria
1. Introduction
The study of vibration in floors has become more of a
necessity in recent years due to the optimization of
materials in building design creating lighter structures,
combined with improvements in research and imaging
technology that demand a more stable operating environ-
ment. Research and healthcare facilities are a prime
example of spaces where a variety of uses and space
optimization places vibration sources closer to vibration
sensitive equipment and processes.
The primary source of vibration in most facilities is
human activity. As people walk, the impact from each
footfall induces floor motions that may easily transmit
to nearby spaces. Quantifying vibration from walking,
whether through measurement of existing spaces or
numerical predictions for guiding the design of a new
facility, is a complex task. This task is complicated in part
by the availability of a number of vibration measurement
and prediction methodologies, each associated with both
similar and unique assumptions. The difficulties in meas-
urement and prediction are further complicated by the
fact that the engineering community has not agreed to a
standard method for quantifying vibration and processing
methods for assessment of spaces of concern.
In this paper we discuss the impact of unwanted
vibrations both from a human perceptibility and sensitive
equipment standpoint. Generic and specific vibration
criteria that are commonly used in international practice
are presented. Several predictive models are discussed
that apply to both steel and concrete construction. Finally,
a case study involving aerobic activity will be presented,
showing the magnitude of vibration that can be induced
by human activity.
2. Impact of Unwanted Vibration
Floor vibration from footfalls and mechanical equip-
ment may be transmitted to the floor structure that
supports vibration sensitive healthcare/laboratory spaces.
Vibration affects sensitive instrumentation by causing
relative motion of its key internal components, or relative
motion between the instrument and the specimen or target
being studied. Figure 1 shows the impact of baseline
ambient vibration conditions on the image of an E. coli
bacterium taken with a Scanning Electron Microscope at
approximately 65,000X magnification.
†Corresponding author : Jon K. GalsworthyE-mail: [email protected]
16 Michael J. Wesolowsky et al. / International Journal of High-Rise Buildings
In healthcare/laboratory spaces housing vibration-
sensitive equipment, floor vibration can:
- Cause exceedances of manufacturer-specified vibra-
tion criteria for equipment within the space;
- Cause substantial “noise” or errors in measurement,
which interferes with the accuracy of measurement
results (e.g., imaging);
- Cause the reliability or performance of the equipment
to deteriorate; and/or,
- In extreme cases, cause damage or result in loss of
equipment calibration.
In addition to their effects on instrumentation, persist-
ent floor vibrations may also cause fatigue and dis-
comfort to building occupants, whether the usage of the
building is commercial or residential. High levels of floor
vibration can render a space unusable by its occupants,
and the impacts can be costly.
3. Vibration Criteria
Over the past 25 years, generic vibration limits have
been developed, which provide frequency dependent
sensitivities for wide classes of equipment, and are used
Figure 1. Coloured scanning electron microscope imagesof E. coli bacterium at approximately 65,000X magnifica-tion under two levels of ambient vibration. Figure 2. Vibration criteria curves.
Table 1. Generic vibration criteria for healthcare spaces (adapted from Amick et al., 2005)
Vibration criteria curveVelocity max level[1]
µm/s (µin/s)Description of Use
Workshop (ISO) 800 (32,000) Distinctly perceptible vibration. Appropriate to workshops and non-sensitive areas.
Office (ISO) 400 (16,000) Perceptible vibration. Appropriate to offices and non-sensitive areas.
Residential day (ISO) 200 (8,000)Barely perceptible vibration. Maximum recommended for general sleep areas.Usually adequate for computer equipment and microscopes with less than 40Xmagnification.
Residential night (ISO) 140 (5,600) Appropriate for most sleep areas such as hospital recovery rooms.
Op. Theatre (ISO) 100 (4,000)Threshold of perceptible vibration. Suitable in most instances for surgical suites,catheterization procedures and microscopes to 100X magnifications and for otherequipment of low sensitivity. Suitable for very sensitive sleep areas.
VC-A 50 (2,000)Adequate in most instances for optical microscopes to 400X, micro-balances, andoptical balances.
VC-B 25 (1,000)Micro-surgery, eye surgery and neurosurgery, CT, CAT, PET, fMRI, SPECT, DOT,EROS.
VC-C 12.5 (500)Appropriate for MRIs, NMRs, standard optical microscopes to 1000X magnifica-tion, and moderately sensitive electron microscopes to 1 µm detail size.
VC-D 6.25 (250)Suitable in most instances for demanding equipment, including may electronmicroscopes (SEMs and TEMs) at more than 30,000X magnification and up to 0.3micron geometries, and E-beam systems.
VC-E 3.12 (125)
A challenging criterion to achieve. Assumed to be adequate for the most demand-ing of sensitive systems including long path, laser-based, small target systems, sys-tems working at nanometer scales and other systems requiring extraordinarydynamic stability.
VC-F 1.56 (62.5)Appropriate for extremely quiet research spaces. Generally difficult to achieve inmost instances. Not recommended for use as a design criterion, only for evaluation.
VC-G 0.78 (31.3)Appropriate for extremely quiet research spaces. Generally difficult to achieve inmost instances. Not recommended for use as a design sriterion, only for evaluation.
Notes: [1] As measured in one-third actave bands of frequency over the frequency range 8 to 80 Hz (ISO, VC-A and VC-B) or 1 to 80 Hz (VC-C through VC-G).
International Journal of
High-Rise Buildingswww.ctbuh.org
International Journal of High-Rise Buildings
March 2012, Vol 1, No 1, 21-28
Strength Evaluation for Cap Plate on the Node Connection in
Circular Steel Tube Diagrid System
Seong-Hui Lee1, Jin-Ho Kim2, and Sung-Mo Choi3†
1Construction Technology Exam. Division, Korean Intellectual Property Office, Daejeon, Korea2Research Institute of Industrial Science & Technology, Incheon, Korea
3Department of Architectural Engineering, University of Seoul, Seoul, Korea
Abstract
Diagrid system has been in the spotlight for its superiority in terms of the resistance to lateral force when applied toskyscrapers. In diagrid system, most of columns can be eliminated because vertical loads (gravity loads) and horizontal loads(lateral loads) are delivered simultaneously thanks to the triangular shape of diagrid. However, lack of studies on connectionshape and node connection details makes it hard to employ the system to the buildings. In this study, the structural safety ofthe node connections in circular steel tube diagrid system which has been considered in the Cyclone Tower in Korea (Sevenstories below and fifty-one above the ground) was evaluated using the 4 full-scale specimens. The parameters are the extendedlength (20 mm, 40 mm & 60 mm), thickness (40 mm & 50 mm).
Keywords: Diagrid, Node, Connection, Stress concentration, Cap plate
1. Introduction
Skyscrapers today are irregular-shaped to be city
landmarks and function as vertical cities to enable the
efficient use of land. 3T (Twisted, Tilted & Tapered)
designs are being suggested for irregular buildings and
studies to develop new structural systems have been
actively made to satisfy slender shape ratio. In this
regard, new structural systems differentiated from tradi-
tional ones are being applied more often than before and
diagrid system is the one most frequently applied.
Diagrid system has been in the spotlight for its super-
iority in terms of the resistance to lateral force when
applied to skyscrapers. In diagrid system, most of columns
can be eliminated because vertical loads (gravity loads)
and horizontal loads (lateral loads) are delivered simul-
taneously thanks to the triangular shape of diagrid. The
behaviors (tensile/compressive) of the diagrid in axial
direction resist shear and thus minimize deformation.
And, it is more applicable to the buildings of irregular
shape than the traditional systems where the lateral
behaviors of columns resist shear and enables excellent
lateral resistance without additional reinforcement of
core. Because of these advantages, diagrid system has
been employed to the Swiss Re Building in London, the
Hearst Tower and the New World Trade Center in New
York, the Twin Tower in Guangzhou, the CCTV Building
in Beijing and Mode Institute in Japan. In Korea, the
diagrid system has been considered in projects for the
Cyclone Tower in Asan, Lotte Super Tower in Seoul and
Future-Ex in Daejeon. However, lack of studies on con-
nection shape and node connection details makes it hard
to employ the system to the buildings. Therefore, con-
nection details should be suggested and developed in
order to promote the application of the system and the
generalization of the connections with secured safety
should backup its application through structural perform-
ance evaluation and reliability verification for the con-
nection details which have been suggested so far.
In this study, the structural safety of the node connec-
tions in circular steel tube diagrid system which has been
considered in the Cyclone Tower in Korea (Seven stories
below and fifty-one above the ground) was evaluated
using the finite element analysis. And, 4 full-scale speci-
mens were fabricated for tests with the variables of
extended length (20 mm, 40 mm & 60 mm) and thickness
(40 mm & 50 mm) of cap plate to suggest economically-
efficient ways to mitigate stress concentration in columns.
1.1. Shape of diagrid connections
Because of the simultaneous resistance to gravity loads
and lateral loads which is inherent in diagrid system,
strong stress is generated in node connections in the
system. Securing reliability of connection details is signi-
ficantly important because of highly complicated stress
generation upon the application of lateral loads. Because
†Corresponding author : Sung-Mo ChoiTel: +82-2-2210-2396; Fax: +82-2-2248-0382E-mail: [email protected]
22 Seong-Hui Lee et al. / International Journal of High-Rise Buildings
diagrid members exist throughout the whole floors of a
building, the constructional efficiency of the connections
plays an importance role in shortening construction period.
Consequently, the node connections of diagrid system
should be decided in terms of construction efficiency and
the workability and constructability of the connections
should be considered from the planning stage in order to
maximize constructional efficiency.
In the diagrid connections of the Cyclone Tower in
Asan, Korea, node connections are formed at the inter-
section of columns as shown in Figure 2. A H-488 × 300 ×
11 × 18 beam made of 600 MPa steel (Fu: 600 MPa) was
set up horizontally at the center of the node connection.
A cap plate was set up at the bottom of a steel tube and
a stiffener plate was set up to support the cap plate.
2. Finite Element Analysis
Finite element analysis was conducted for the connec-
tions of the Cyclone Tower to evaluate their structural
performance.
2.1. Finite element analysis of cap plate
Increasing cap plate thickness and extending its length
have been suggested as the methods to mitigate stress
concentration in connections. So, the finite element analy-
sis was conducted for the two suggestions in this study.
2.2. Analysis model & method
Four objects with the variables of the extended length
Figure 1. Cyclone Tower in Asan, Korea.
Figure 2. Cyclone Tower, using diagrid system.
International Journal of
High-Rise Buildingswww.ctbuh.org
International Journal of High-Rise Buildings
March 2012, Vol 1, No 1, 29-36
Experimental and Analytical Investigation of Web-transferred
Diagrid Node under Seismic Condition
Inyong Jeong, Young K. Ju†, and Sang-Dae Kim
School of Civil, Environmental, and Architectural Engineering, Korea University, Seoul, Korea
Abstract
The diagrid structural system is considered to be not only the best structural system for constructing free form structures, butalso a very effective system in resisting lateral load. As a newly investigated structural system, its complicated node has notyet been completely investigated and minimal experimentation of manufacturing and constructing the system have beenconducted. Therefore, the constructing cost of the diagrid structural system is still comparatively high. In this paper, the cyclicperformance of a diagrid node with an H-section brace will be discussed. Design details that consider productivity wereproposed and their structural performances were assessed through experimental and analytical investigation
Keywords: Diagrid, Node, Web-transferred, Test, Analysis
1. Introduction
The development of structural technology makes it
possible to construct higher buildings. Attempts to defy
gravity have been performed in many ways, such as
developing high strength materials or new structural
systems. However, aesthetic variety has been limited to
only low-rise buildings or to the use of several methods
such as set-backs or a change of exterior materials.
Recently, however, aesthetic diversities in tall buildings
have been attracting people’s attention, and many
attempts at aesthetic diversity are being made, resulting in
the current trend of 3T (Twisted, Tilted and Tapered).
Among these attempts, the diagrid structural system is
gaining acceptance as the most appropriate structural
system for free form tall buildings. The most distinctive
characteristic of the diagrid system is that it has no
vertical columns and consists of triangular modules,
braces and beams, resisting external forces. This charac-
teristic provides free form buildings with many possi-
bilities. Also, these triangular modules act as trusses
resisting external forces with their axial behavior and
very high structural efficiency. The Heast Tower in New
York saved 20% steel material using the diagrid system
(Rahimian, 2006).
Despite these merits, study of the diagrid system is at
an initial stage. Several theoretical studies such as seismic
performance factors (Kim, 2009; Kim, 2009), optimal
angles (Moon, 2007) and progressive collapse (Kim,
2008) are in progress. Construction cost is relatively high
due to the lack of production and construction experience.
To overcome this lack of experience, a series of tests
were conducted and supported by the Korea Institute of
Construction and Transportation Technology Evaluation
and Planning. With this support, a material test, monotonic
tensile/compressive test, mock-up test, cyclic test, and
frame test were conducted and are illustrated in Figure 1.
Among these tests, the cyclic test will be discussed in this
paper, including further research about the test. The
seismic performance of diagrid nodes with H-section
braces was assessed through experimental and analytical
studies. The analysis was conducted using the same con-
dition as that of the cyclic test and the results were well
matched with the test results. Therefore, the generalized
behavior of the diagrid node was derived by expanded
parameter analysis.
†Corresponding author : Young K. JUTel: +82-2-3290-3327; Fax: +82-2-928-7656E-mail: [email protected] Figure 1. A series of Diagrid experiments.
30 Inyong JEONG et al. / International Journal of High-Rise Buildings
2. Experimental Study
2.1. Test specimen
Figure 2 illustrates the test specimen. The X-shape node
at which the H-section braces are intersected has a con-
tinuous flange and transferred web. Through the trans-
ferring zone, the axial stress of the web flows to the side
stiffener.
The parameters of the web-transferred node are the
overlapped length between the side stiffener and web, and
the welding method of the major parts. The stress trans-
ferring efficiency of the transferring zone depends on the
overlapped length; therefore, the structural performances
of the node according to the overlapped length were deter-
mined. For tall buildings, very thick plates, and conse-
quently a considerable amount of welding, are used to
manufacture the diagrid nodes. If partial penetration
welding, which reduces the amount of welding required,
can be applied in manufacturing the nodes, the total
welding amount would be decreased significantly. There-
fore, the partial penetrating welding method is introduced
as a parameter.
Five specimens are illustrated in Figure 3, and the para-
meters are tabulated in Table 1. The MA-00, MA-01 and
MA-02 specimens have the same form, with an over-
lapped length of 70 mm, while their welding methods
differ. The MA-03 and MA-04 specimens have an over-
lapped length of 105 mm and 42 mm, respectively.
2.2. Test setup
To describe a structure that is applied by lateral forces,
tensile force is applied to one brace and compressive
force is applied to the other brace. The angle between the
two braces is 24 degrees, and is scaled to 1/5. Yield
strength and displacement are calculated with the area of
brace section in Eq. (1) and Eq. (2).
(1)
(2)
Forces are applied twice at one cycle and the magni-
tude is increased as axial deformation of the brace
reaches 2 mm, 4 mm, 8 mm and 12 mm, which is one,
two, four and six times of yield displacement, respect-
ively (Figure 4). The tests are completed when the speci-
mens are fractured or the applied load is decreased to
80% of maximum strength.
Figure 5 shows the test setup. Two actuators were
installed at each brace to apply tensile and compressive
loads to each brace simultaneously. For the convenience
of the test setup, the lower actuator was installed horizon-
Pu
Fy
Ag
× 357MPa 6 720mm2
,× 2 400kN,≈= =
δy
PyL/EA
2 400kN, 103
× 1 200mm,×
210 000MPa, 6 720mm2
,×
------------------------------------------------------------- 2mm≈= =
Figure 2. 3D image of specimen.
Figure 3. Details of parameters.
Table 1. List of specimens
Specimens MA-00 MA-01 MA-02 MA-03 MA-04
Web-Flange welding FP(a) PP(b) PP PP PP
Flange-Flange welding FP FP PP PP FP
Side stiffener welding FP FP FP PP FP
Overlapped length L(c) L L 1.5L 0.6L
(a) FP: Full Penetration welding, (b) PP: Partial Penetration weld-ing, (c) L = 70 mm.
International Journal of
High-Rise Buildingswww.ctbuh.org
International Journal of High-Rise Buildings
March 2012, Vol 1, No 1, 37-51
Validating the Structural Behavior and Response of Burj Khalifa:
Synopsis of the Full Scale Structural Health Monitoring Programs
Ahmad Abdelrazaq†
Headg, Highrise & Complex Building, Samsung C&T, Seoul, Korea
Abstract
New generation of tall and complex buildings systems are now introduced that are reflective of the latest development inmaterials, design, sustainability, construction, and IT technologies. While the complexity in design is being overcome by theavailability and advances in structural analysis tools and readily advanced software, the design of these buildings are still relianton minimum code requirements that yet to be validated in full scale. The involvement of the author in the design andconstruction planning of Burj Khalifa since its inception until its completion prompted the author to conceptually develop anextensive survey and real-time structural health monitoring program to validate all the fundamental assumptions mad for thedesign and construction planning of the tower.
The Burj Khalifa Project is the tallest structure ever built by man; the tower is 828 meters tall and comprises of 162 floorsabove grade and 3 basement levels. Early integration of aerodynamic shaping and wind engineering played a major role in thearchitectural massing and design of this multi-use tower, where mitigating and taming the dynamic wind effects was one ofthe most important design criteria established at the onset of the project design. Understanding the structural and foundationsystem behaviors of the tower are the key fundamental drivers for the development and execution of a state-of-the-art surveyand structural health monitoring (SHM) programs. Therefore, the focus of this paper is to discuss the execution of the surveyand real-time structural health monitoring programs to confirm the structural behavioral response of the tower duringconstruction stage and during its service life; the monitoring programs included 1) monitoring the tower’s foundation system,2) monitoring the foundation settlement, 3) measuring the strains of the tower vertical elements, 4) measuring the wall andcolumn vertical shortening due to elastic, shrinkage and creep effects, 5) measuring the lateral displacement of the tower underits own gravity loads (including asymmetrical effects) resulting from immediate elastic and long term creep effects, 6)measuring the building lateral movements and dynamic characteristic in real time during construction, 7) measuring thebuilding displacements, accelerations, dynamic characteristics, and structural behavior in real time under building permanentconditions, 8) and monitoring the Pinnacle dynamic behavior and fatigue characteristics. This extensive SHM program hasresulted in extensive insight into the structural response of the tower, allowed control the construction process, allowed for theevaluation of the structural response in effective and immediate manner and it allowed for immediate correlation between themeasured and the predicted behavior.
The survey and SHM programs developed for Burj Khalifa will with no doubt pioneer the use of new survey techniques andthe execution of new SHM program concepts as part of the fundamental design of building structures. Moreover, this surveyand SHM programs will be benchmarked as a model for the development of future generation of SHM programs for all criticaland essential facilities, however, but with much improved devices and technologies, which are now being considered by theauthor for another tall and complex building development, that is presently under construction.
Keywords: Realtime-structural health monitoring program, Construction sequence analysis, Survey monitoring programs,cloumn shortening, Gravity load management, wind seismic engineering management, Foundation settlement
1. Introduction
The Burj Khalifa Project is the tallest structure ever
built by man, Figure 1, that rises 828 meters into Dubai
skyline tall and it consists of 162 floors above grade and
3 basement levels. While integrating wind engineering
principles and aerodynamic shaping into the architectural
design concept was an important consideration in miti-
gating and taming the dynamic wind effects, managing
the gravity load flow to the building extremities was
equally significant in overcoming the overturning mo-
ment due to extreme lateral loads. Most of the tower
overturning resistance is managed mostly by the tower’s
own gravity loads. In addition, all the vertical members
are proportioned to resist gravity loads on equal stress
basis to overcome the differential column shortening
issues that are generally difficult to manage in supertall
buildings.
The structure of Burj Khalifa was designed to behave
like a giant column with cross sectional shape that is a
†Corresponding author : Ahmad Abdelrazaq Tel: +82-2-2145-5190, Fax: +82-2-2145-6631 E-mail: [email protected]
38 Ahmad Abdelrazaq / International Journal of High-Rise Buildings
reflection of the building massing and profile. The story
of structural system selection and the structural system
optimization is a novel one and cannot be covered here in
details, however, this paper will provide 1) a brief on the
key issues that led to the structural system selection and
the key issues considered in integrating structural design
concepts and construction planning into the architectural
design concept, 2) a detailed understanding of the overall
structural and foundation system behaviors of the tower
that are considered critical to the development of the
survey and structural health monitoring (SHM) programs
for the tower; 3) and a detailed description of the compre-
hensive real-time SHM and survey programs developed
for Burj Khalifa.
The development of the survey and SHM program for
Burj Khalifa, at the time of the system installation, is
probably one of the most comprehensive survey and real-
time SHM programs in the history of supertall buildings
that will track the structural behaviors and responses of
the tower during construction and during its lifetime and
it included:
- Monitoring the reinforced concrete bored piles and
their load dissipation into the soil.
- Survey and monitoring of the tower foundation settle-
ment, corewalls and column vertical shortening, and
the lateral displacements of the tower resulting from
its asymmetrical geometric shape and structural
system asymmetry.
- Monitoring of the tower vertical element strains and
stresses due to gravity load effects.
- Installation of a Temporary Real Time Monitoring
Program to monitor the building displacement and
dynamic response under lateral loads (wind and
seismic) during construction.
- Installation of Permanent Real Time Monitoring
Program to monitor the building displacement and
dynamic response under lateral loads (wind and
seismic in particular). The intent of this monitoring
program is to confirm the actual dynamic character-
istics and response of the building, including its
natural mode of vibration, estimate of damping,
measuring the building displacement and accel-
eration, immediate diagnose of the change in build-
ing structural behavior, identify potential of fatigue at
structural elements that are considered fatigue sen-
sitive and that could be subjected to severe and
sustained wind induced vibration at different wind
speeds and profiles, and most importantly in pro-
viding real-time feedback on the performance of the
building structure and immediate assistance in their
day-to-day operations, etc.
- Providing sufficient data to predict the fatigue
behavior of the pinnacle under low/moderate/severe
wind and seismic excitations.
- Tracking the wind speed profile along the building
height in an urban, but semi open field setting con-
sidering the scale of the project relative to its
surroundings.
- Correlating the building measured responses with the
predicted behavior of the tower.
These extensive survey and SHM programs have, since
their inception, resulted already in an extensive feedback
and insight into the actual in-situ material properties, the
towers structural behavior and response under wind and
seismic excitations, and continuous change in the building
characteristics during construction. In addition and most
importantly, the SHM program will provide the building
owner ongoing and continuous feedback on the perform-
Figure 1. Photo of the Completed Burj Khalifa.
International Journal of
High-Rise Buildingswww.ctbuh.org
International Journal of High-Rise Buildings
March 2012, Vol 1, No 1, 53-59
Parametric Analysis and Design Engine for Tall Building Structures
Goman Ho1†, Peng Liu2, and Michael Liu2
1Arup, 5/F, Festival Walk, 80 Tat Chee Avenue, Kowloon Tong, Hong Kong SAR, China2Arup, 3008, 30/F, Jing Guang Centre, Hu Jia Lou, Chaoyang Dirtrict, Beijing 100020, China
Abstract
With the rise in CPU power and the generalization and popularity of computers, engineering practice also changed from handcalculations to 3D computer models, from elastic linear analysis to 3D nonlinear static analysis and 3D nonlinear transientdynamic analysis. Thanks to holistic design approach and current trends in freeform and contemporary architecture, BIMconcept is no longer a dream but also a reality. BIM is not just providing a media for better co-ordination but also to shortenthe round-the-clock time in updating models to match with other professional disciplines. With the parametric modeling tools,structural information is also linked with BIM system and quickly produces analysis and design results from checking tofabrication. This paper presents a new framework which not just linked the BIM system by means of parametric mean but alsocreate and produce connection FE model and fabrication drawings etc. This framework will facilitate structural engineers toproduce well co-ordinate, optimized and safe structures.
Keywords: BIM, Parametric modeling, Structural analysis, Finite element
1. Introduction and Background
It is interesting to know that the A5 CPU used in a
hand phone (such as iPhone 4S) or tablet is more power-
ful than a Cray 2 computer which cost US$17m[1] in
1985. Following the first Z1 computer in 1935, the size of
computer is reducing but increase in speed. In 1965,
Gordon Moore presented his Moore’s Law that the
components in integrated circuit doubles every ten years.
In early 80’s, the availability of minicomputers allowed
software applications shifted from military or aerospace
industry to domestic use. One of the well known is the
release of Unigraphics system by McDonnell Douglas.
Unigraphics converted the Automated Drafting and Ma-
chining (ADAM) coding into current named as Computer
Aided Design (CAD), Computer Aided Manufacturing
(CAM) and Computer Aided Engineering (CAE) appli-
cations. Although Unigraphics was already in 3D, the
cost of minicomputer was still too expensive for some
small firms which were common in buildings industry by
that time.
Following the very early Personnel Computer (Apple I)
assembled by two youngsters in mid-80’s, the cost of
computers became more affordable by building industry
practices. The work for draftsman changed from hand
drawings to 2D CAD drawings and in 90’s in 3D draw-
ings. With 3D environment, the true communication lan-
guage of Architecture, Engineering and Construction
(AEC) industry is no longer “drawings” as emphasized
by Carl Culmann by 1860’s. It is because the structures
are getting more complicated and hardly be defined by
means of 2D drawings. The definition of drawings now-
adays may mean - “3D objects”.
At the same time, structural engineers also changed
their practice from hand calculations to now very complex
3D nonlinear transient dynamic analysis. Without com-
puters and software, a lot of ideas will still be on a piece
of paper. For examples, the geometry of Watercube for
Beijing Olympics was created by scripts and then analy-
zed by computer. The National Stadium geometry was
first created by CATIA; box sections were “intruded”
following the centerline and twisted to ensure the external
envelope which follows the “Bow” shape.
Although there were drawings for both Watercube and
National Stadium projects, the 3D computer model were
still the key for communication between various parties
from designer to fabricators and erectors.
2. BIM
With the popularity of 3D modeling techniques, the
industry is moving forward to Building Information
Modeling (BIM) in early 20’s. According to Ghang Lee[2],
“BIM is the “process” of generating and managing build-
ing information in an interoperable and reusable way. A
BIM system is a system or a set of systems that “enables”
users to integrate and reuse building information and
domain knowledge through the lifecycle of a building”.
In the early stage of BIM, structural engineers use BIM
to produce the global model of the building structures and
†Corresponding author : Tel: +852-2268-3154; Fax: +852-2268-3945E-mail: [email protected]
54 Goman Ho et al. / International Journal of High-Rise Buildings
BIM is only a tool to produce computer models. Figure 3
show an architectural image of a building project, the
Revit 3D and GSA (structural analysis) model. Through
BIM tools, engineers can extract the floor plan and
produce the floor plan in seconds as Figure 4.
3. Parametric Modeling
Because of the trends in free form surface, contem-
porary architecture requirement and buildings getting
taller, the automation of generating the global structural
Figure 1. Photo of National Stadium and WaterCube for 2008 Beijing Olympics (©Marcel Lam Photography).
Figure 2. CATIA Model showing the twisting and bending of box elements in National Stadium.
Figure 3. Architect Image (With courtesy of Studio PeiZhu) Vs Revit Model Vs GSA Structural Model.
International Journal of
High-Rise Buildingswww.ctbuh.org
International Journal of High-Rise Buildings
March 2012, Vol 1, No 1, 61-72
Anything Goes?
Dennis Poon† and Leonard Joseph
Thornton Tomasetti, Inc.
Abstract
When Cole Porter wrote the song “Anything Goes” in 1934, he did not include skyscraper examples. The recently completedChrysler and Empire State buildings followed decades of tall building development in a logical and predictable line. Today,dramatic improvements in materials and methods of analysis, design and fabrication have given architects and engineersfreedom to imagine, and contractors to build, towers in configurations never seen before. If writing now, Porter would surelyhave mentioned such designs to demonstrate anything goes. Or does it? This article explores the possibilities and challengesof tall building structural design through current and proposed projects. Examples include engineering buildings with outwardforms that appear structurally unfavorable and taking advantage of load reduction through shaping opportunities.
Keywords: High-rise buildings, Anything goes?
1. Introduction
‘Pushing the envelope’ and ‘Thinking outside the box’
are widely used expressions. While ‘envelope’ originally
referred to aircraft performance limits, and ‘box’ to the
boundaries of a nine-dot puzzle, these days both phrases
could easily relate to building design and construction.
Digital modeling, designing, detailing and fabrication tools
developed in recent years have made unusual shapes and
complex geometries practical to construct, if not neces-
sarily the most economical solutions. Current and planned
cutting-edge buildings are indeed pushing building enve-
lopes to new shapes, and those shapes are often far from
boxy. As composer Cole Porter named his song, “Any-
thing Goes.”
In the world of tall towers, does anything goes still
apply? On one hand, big buildings have big budgets and
the potential for economies of scale: research and testing
for determining performance of a cutting-edge technology
may be too great a cost for a small project, and small
production runs may result in high unit costs, but the
reverse is true for a mega project. For a large building, it
can make sense to create and dedicate a factory to manu-
facture a custom design, where the performance payoff is
great enough. On the other hand, size and scale pose their
own challenges, including the need to consider four non-
negotiable conditions: gravity load, wind behavior, earth-
quake response and geometric limitations. One or more
conditions can govern building structural design, based
on the direction of the overall building concept. Rather
than ‘anything goes,’ a better, if less catchy phrase might
be ‘any goal by taking the right direction.’ Key decisions
make the difference between theoretically possible but
unaffordable concept sketches and practical, affordable
completed buildings. Identifying key decisions early and
finalizing them as a collaborative process within the owner-
ship/design/construction team is essential, as will be shown
through case histories of contemporary projects.
Let’s start with gravity, a constant and ubiquitous effect
that cannot be ignored. What if we actually push the
(building) envelope over, literally, by building on a slant?
Gravity creates a tower overturning moment with zero
story shear force. The 26-story, 374-ft (114 m) mirror-
image Puerta de Europa towers in Madrid, Spain designed
by Philip Johnson/John Burgee and engineer Leslie E.
Robertson Associates and completed in 1996, lean toward
each other by 15 degrees from vertical. The concept is
visually simple: the side elevation of each tower is a
parallelogram with the outer edge of the roof almost over
the inner edge at the ground. See Figure 1. In theory a
building of uniform density could simply balance its
weight on that inner corner. In practice balancing a
building on a fulcrum leaves no reserve against additional
moments from wind or earthquakes. Directing load to
such a balance point would also be difficult, as floors in
tall narrow buildings typically span from perimeter
columns to a central core, which is needed anyway for
vertical circulation and services (elevators and stairs,
water, power and telecom risers). Even for a core located
near the inside bottom corner to fit vertically within the
parallelogram shape, gravity loads will not conveniently
flow to the inside corner. In theory a core could resist the
overturning moment, but it would be impractically costly
†Corresponding author: Dennis PoonTel: +1-917-661-7800, Fax:+1-917-661-7801E-mail: [email protected]
62 Dennis Poon and Leonard Joseph / International Journal of High-Rise buildings
for a gravity overturning moment many times greater
than the wind overturning moment. Connecting the outer
sloping face to the core where they meet at the roof uses
geometry to advantage, creating a tall, stiff triangle against
overturning. Triangulation, however, is only a partial
solution to the challenge due to load reversal and strain
effects.
The outer sloping face columns could cycle between
tension and compression from minor lateral loads, com-
plicating determination of effective stiffness and splice
designs. Construction-phase strains are also complicated:
overturning effects deform the entire building as upper
levels are built, potentially pulling lower floors out of
alignment, but the triangulation achieved at the top could
lock in misalignments whether intentional or not. Long-
term strains in central core concrete will occur from
shrinkage as its relative humidity approaches that of
conditioned air in the building, and from creep under
sustained load such as dead load, a continued increase in
strain over time that gradually slows years after con-
struction. Where compressive stress varies due to flexure,
creep will exaggerate core curvature and upper floor
displacements.
The engineer’s solution to all these concerns was post-
tensioning, running high strength tendons along the outer
sloping face from a 15,400 ton (14,000 tonne) counter-
weight below grade to jacking points at the roof level.
Tensioning the tendons compresses the outer face columns,
keeping joints in contact for maximum stiffness. As the
outer face columns shorten from induced compressive
strain, the horizontal component of that movement draws
the roof level and core top sideways, creating a righting
moment that offsets base overturning and minimizes
stress differences across the core and resulting deforma-
tions from differences in creep. While not supertall build-
ings, the Puerta de Europa towers illustrate the complex
and subtle ways that arbitrary forms can affect building
strength and behavior, the value of strategic decisions to
provide effective solutions to such challenges and the cost
premiums associated with unusual designs.
Another visually dramatic building design with both
gravity and seismic challenges is the CCTV Headquarters
building in Beijing, China. The design by Rem Koolhass
of the firm Office of Metropolitan Architecture (OMA)
was engineered by Arup. Two towers sloping six degrees
are joined at the base by a building extension forming an
L in plan. The towers are also joined at the upper floors
by an opposite L in plan as separate cantilevers meet at
a right angle to form a bent torsional tube. See Figures
2(a) and 2(b).
At 49 stories and 768 ft (234 m) in height the building
is not a supertall tower, but presents numerous design
challenges. Its large cantilevers mean that balancing gra-
vity loads about a tower edge is not remotely possible.
Gravity overturning must be resisted by the structure. The
designers chose to develop maximum stiffness by bracing
Figure 1. Puerta de Europa Elevation. Credit: Royal Production, Philip John /Alan Ritchie Architects.
Introduction to Paper Submission
Everyone is welcome to submit a research paper on a tall building related topic. Authors are asked to submittheir manuscripts to [email protected]
[Review Process]
Upon receiving the manuscript, the Co-Chief-Editor assigns an appropriate member of the Editorial Board to
review the manuscript. When the manuscript is accepted for the refereeing process, the Co-Chief-Editor
identifies three competent reviewers who are acknowledged experts in the given subject for extensive peer
review. The reviewer’s names will remain anonymous to the authors of the manuscript. The Co-Chief-Editor
informs authors about the feedback received from the peer reviewers. Only those receiving favorable
recommendations from the peer reviewers will be accepted for publication.
It may be required to make revisions of the manuscript based on the feedback of the peer reviewers. The
Co-Chief-Editor reserves the right to adjust the author’s style according to certain standards of uniformity.
[Style Guide]
Please consider the following style guide requirements when preparing a paper:
Manuscripts should be written in English, and typed double-spaced with 2.5 centimeter (1 inch) wide margins
on one side of A4 (210 × 297 mm) size paper, with a font size of 10 pt in no more than 20 manuscript pages,
including tables and illustrations. Each page of the paper must be numbered. All measurements and data
should be expressed in SI-units or in an internationally accepted unit if SI units are not applicable.
Order:
Manuscripts should be arranged in the following order;
1. title, author’s name, affiliation, full postal addresses, telephone, fax, and e-mail address(*);
2. an abstract of about 100-150 words in a single paragraph, purpose, scope, and conclusions of the paper;
3. about five key words for indexing purposes;
4. text with tables and figures, divided under suitable headings and subheadings;
5. acknowledgment (if any);
6. appendix;
7. references.
*The corresponding author should be identified by e-mail address. Full postal addresses must be given for
all co-authors.
References:
References should be cited by the last name(s) of the author(s) and the year of publication (e.g., Bendat and
Piersol, 1959). They should be listed at the last part of the manuscript, arranged in alphabetical order by the
last name of the first author. References should be listed by following the format of the examples below;
Journal: Jeary, A. P. (1986) "Damping in buildings - a mechanism and a predictor." Journal of
Earthquake Engineering and Structural Dynamics, 14, pp. 733~750.
Book: Bendat, J. and Piersol, A. (1986) Random data analysis and measurement procedures.
John Wiley & Son, New York, USA.
Proceedings: Tamura, Y. (2003) "Design issues for tall buildings from accelerations to damping
-Tribute to Hatsuo Ishizaki and Vinod Modi-." Proc. the 11th International Conference on
Wind Engineering, INV.W2, Lubbock, Texas, USA, June, pp. 81~114.
Tables:
Tables should be numbered consecutively, and each must be given a short caption. They should be referred
to in the text as Table 1, etc. All figures, including photographs, charts, and diagrams, should be provided in
camera-ready form, and must be suitable for reproduction without modification. They should be numbered and
referred to in the text as Fig. 1, etc. The smallest allowable size for the figures is 6 pt after reduction.
Tables should be typed above them and figures should be typed below them, using superscript lowercase
letters. Equations should be numbered consecutively in parentheses on the right-hand side of the page. They
should be referred to in the text as Eq. (1), etc. Special symbols should be identified at the margins, and the
meanings of all the symbols should be explained in the section of the text where they first appear.
[Procedure]
Manuscripts that need revision prior to final acceptance shall be returned together with the reviewers’ reports.
The revised version must be submitted as soon as possible; revised manuscripts returned after four months
will be considered as new submissions subjected to full reassessment. After the final acceptance of the
manuscript, an MS-Word file should be submitted.
A layout proof will be sent to the first named author and should be returned within one week of receipt.
Corrections should be restricted to typesetting errors in this stage.
Feedback queries should be answered in full. Please note that authors are urged to check their proofs
carefully before returning the manuscript since the inclusion of late corrections cannot be guaranteed. Proofs
should be returned via E-mail to [email protected].
Off-prints: Twenty-five (25) off-prints of the paper and one copy of the journal will be supplied free of charge.
Off-prints and copies of the issue can be ordered at a specially reduced price upon request after the
manuscript has been accepted.
[Copyright]
All authors must sign the “Transfer of Copyright” agreement before the paper can be published.
[Contact]
For further information or inquiries, please contact [email protected].
For overview of the International Journal of High-Rise Buildings (IJHRB), please visit Journal Overview.