image gated cardiac ct lsu medical physics seminar february 4, 2005 given by will hill with advice...
TRANSCRIPT
![Page 1: Image Gated Cardiac CT LSU Medical Physics Seminar February 4, 2005 Given by Will Hill With advice from Dr. Kip Mathews A presentation of “Automatic Phase](https://reader035.vdocuments.net/reader035/viewer/2022070415/5697bf831a28abf838c86831/html5/thumbnails/1.jpg)
Image Gated Cardiac CT
LSU Medical PhysicsSeminar
February 4, 2005Given by Will Hill
With advice from Dr. Kip Mathews
A presentation of“Automatic Phase Determination for Retrospectively Gated
Cardiac CT” fromthe December 2004 issue of Medical Physics
![Page 2: Image Gated Cardiac CT LSU Medical Physics Seminar February 4, 2005 Given by Will Hill With advice from Dr. Kip Mathews A presentation of “Automatic Phase](https://reader035.vdocuments.net/reader035/viewer/2022070415/5697bf831a28abf838c86831/html5/thumbnails/2.jpg)
Introduction and Objectives
What is Gated Cardiac Computed Tomography (CT) ?
Why bother? What This Lecture will cover:
Basics of CT Basics of cardiac timing How this is done now How the author did it The author's results
![Page 3: Image Gated Cardiac CT LSU Medical Physics Seminar February 4, 2005 Given by Will Hill With advice from Dr. Kip Mathews A presentation of “Automatic Phase](https://reader035.vdocuments.net/reader035/viewer/2022070415/5697bf831a28abf838c86831/html5/thumbnails/3.jpg)
Literature Review
“Automatic Phase Determination for Retrospectively Gated Cardiac CT,” by R. Manzke, Th. Kohler, T. Neilsen, D. Hawkes and M. Grass, Medical Physics 31-12.
The Essential Physics of Medical Imaging, Lippncott Williams and Wilkins, Second Edition.
![Page 4: Image Gated Cardiac CT LSU Medical Physics Seminar February 4, 2005 Given by Will Hill With advice from Dr. Kip Mathews A presentation of “Automatic Phase](https://reader035.vdocuments.net/reader035/viewer/2022070415/5697bf831a28abf838c86831/html5/thumbnails/4.jpg)
The Basics of Computed Tomography
Who Likes Guessing Games?
![Page 5: Image Gated Cardiac CT LSU Medical Physics Seminar February 4, 2005 Given by Will Hill With advice from Dr. Kip Mathews A presentation of “Automatic Phase](https://reader035.vdocuments.net/reader035/viewer/2022070415/5697bf831a28abf838c86831/html5/thumbnails/5.jpg)
The Basics of Computed Tomography
How about this one?
![Page 6: Image Gated Cardiac CT LSU Medical Physics Seminar February 4, 2005 Given by Will Hill With advice from Dr. Kip Mathews A presentation of “Automatic Phase](https://reader035.vdocuments.net/reader035/viewer/2022070415/5697bf831a28abf838c86831/html5/thumbnails/6.jpg)
The Basics of Computed Tomography
Pretend you can't see through it.
![Page 7: Image Gated Cardiac CT LSU Medical Physics Seminar February 4, 2005 Given by Will Hill With advice from Dr. Kip Mathews A presentation of “Automatic Phase](https://reader035.vdocuments.net/reader035/viewer/2022070415/5697bf831a28abf838c86831/html5/thumbnails/7.jpg)
The Basics of Computed Tomography
and that you have x-rays and a counter.
![Page 8: Image Gated Cardiac CT LSU Medical Physics Seminar February 4, 2005 Given by Will Hill With advice from Dr. Kip Mathews A presentation of “Automatic Phase](https://reader035.vdocuments.net/reader035/viewer/2022070415/5697bf831a28abf838c86831/html5/thumbnails/8.jpg)
The Basics of Computed Tomography
Ta-dah!
![Page 9: Image Gated Cardiac CT LSU Medical Physics Seminar February 4, 2005 Given by Will Hill With advice from Dr. Kip Mathews A presentation of “Automatic Phase](https://reader035.vdocuments.net/reader035/viewer/2022070415/5697bf831a28abf838c86831/html5/thumbnails/9.jpg)
The Basics of Computed Tomography
So, that's how it works.
![Page 10: Image Gated Cardiac CT LSU Medical Physics Seminar February 4, 2005 Given by Will Hill With advice from Dr. Kip Mathews A presentation of “Automatic Phase](https://reader035.vdocuments.net/reader035/viewer/2022070415/5697bf831a28abf838c86831/html5/thumbnails/10.jpg)
Timing: Your Heart
![Page 11: Image Gated Cardiac CT LSU Medical Physics Seminar February 4, 2005 Given by Will Hill With advice from Dr. Kip Mathews A presentation of “Automatic Phase](https://reader035.vdocuments.net/reader035/viewer/2022070415/5697bf831a28abf838c86831/html5/thumbnails/11.jpg)
Timing: Your Heart
![Page 12: Image Gated Cardiac CT LSU Medical Physics Seminar February 4, 2005 Given by Will Hill With advice from Dr. Kip Mathews A presentation of “Automatic Phase](https://reader035.vdocuments.net/reader035/viewer/2022070415/5697bf831a28abf838c86831/html5/thumbnails/12.jpg)
Timing: EKG Methods Triggered Continuous
![Page 13: Image Gated Cardiac CT LSU Medical Physics Seminar February 4, 2005 Given by Will Hill With advice from Dr. Kip Mathews A presentation of “Automatic Phase](https://reader035.vdocuments.net/reader035/viewer/2022070415/5697bf831a28abf838c86831/html5/thumbnails/13.jpg)
Materials and Method
This Method: Low Pitch Helical Cardiac Scan and ECG Reconstruction of Low-Resolution 4D Volume Automatic Motion Calculations Reconstruction of High Resolution Volumes
Philips MX 8000 IDT 16-line CT system at University Hospital in Ulm, Germany and at the Carmel Hospital in Haifa, Israel.
![Page 14: Image Gated Cardiac CT LSU Medical Physics Seminar February 4, 2005 Given by Will Hill With advice from Dr. Kip Mathews A presentation of “Automatic Phase](https://reader035.vdocuments.net/reader035/viewer/2022070415/5697bf831a28abf838c86831/html5/thumbnails/14.jpg)
Similar Low Resolution Volumes
![Page 15: Image Gated Cardiac CT LSU Medical Physics Seminar February 4, 2005 Given by Will Hill With advice from Dr. Kip Mathews A presentation of “Automatic Phase](https://reader035.vdocuments.net/reader035/viewer/2022070415/5697bf831a28abf838c86831/html5/thumbnails/15.jpg)
Motion Determination
![Page 16: Image Gated Cardiac CT LSU Medical Physics Seminar February 4, 2005 Given by Will Hill With advice from Dr. Kip Mathews A presentation of “Automatic Phase](https://reader035.vdocuments.net/reader035/viewer/2022070415/5697bf831a28abf838c86831/html5/thumbnails/16.jpg)
Motion Map
![Page 17: Image Gated Cardiac CT LSU Medical Physics Seminar February 4, 2005 Given by Will Hill With advice from Dr. Kip Mathews A presentation of “Automatic Phase](https://reader035.vdocuments.net/reader035/viewer/2022070415/5697bf831a28abf838c86831/html5/thumbnails/17.jpg)
Results
Simulation Study Three Patient's Data
![Page 18: Image Gated Cardiac CT LSU Medical Physics Seminar February 4, 2005 Given by Will Hill With advice from Dr. Kip Mathews A presentation of “Automatic Phase](https://reader035.vdocuments.net/reader035/viewer/2022070415/5697bf831a28abf838c86831/html5/thumbnails/18.jpg)
Conclusions
Computational Efficiency similarity is easy low resolution scans are used first
Automatically Reduces Motion Artifacts patient and cycle variation are accounted for different phases can be used for different heart
segments by use of new motion maps
![Page 19: Image Gated Cardiac CT LSU Medical Physics Seminar February 4, 2005 Given by Will Hill With advice from Dr. Kip Mathews A presentation of “Automatic Phase](https://reader035.vdocuments.net/reader035/viewer/2022070415/5697bf831a28abf838c86831/html5/thumbnails/19.jpg)
The Future
Authors promise larger clinical trials.