![Page 1: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/1.jpg)
Imaging the Developing Embryonic Heart:
Combining Fast Confocal Microscopes
with 4D Reconstruction Techniques
Michael Liebling1, Arian S. Forouhar1,Mory Gharib1, Scott E. Fraser1, Mary E. Dickinson1,2
1California Institute of Technology2Baylor College of Medicine, Houston TX
http://www.its.caltech.edu/∼liebling/
<< < > >> B F R I Page 1
![Page 2: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/2.jpg)
VBA
SV
A
1 day post fertilization 5 days post fertilization
Goals• Determine genetic & epigenetic factors contributing to heartdevelopment• Dynamic 3D imaging in vivo, over various developmental stages• Measure volume changes, blood flow, shear stress, etc.ChallengeEven state-of-the-art laser scanning confocal microscopes are notfast enough for high-speed, real-time 3D image acquisition
Studying the Developing Zebrafish Heart
<< < > >> B F R I Page 2
![Page 3: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/3.jpg)
A
V
Advantages:• zebrafish are vertebrates• reproduce externally and rapidly• relatively transparent• may be genetically engineered toexpress fluorescent markers in spe-cific tissues [e.g. Tg(gata1::GFP)]
48 hpf (hours post fertilization)mb: midbrainot: otocyste: eyeh: heartyolk: yolk mass
Imaging in the Zebrafish Embryo
<< < > >> B F R I Page 3
![Page 4: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/4.jpg)
Fluid forces contribute to heart formation
Acquisition:Widefield, 440 frames/sAnalysis:Digital Particle Image Ve-locimetry
J.R. Hove, R.W. Köster,A.S. Forouhar, G. Acevedo-Bolton, S.E. Fraser, andM. Gharib,“Intracardiac fluid forces are anessential epigenetic factor forembryonic cardiogenesis,”Nature, 421, 172–177 (2003).
Genetic and Epigenetic Factors in Cardiogenesis
<< < > >> B F R I Page 4
![Page 5: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/5.jpg)
J.R. Hove, R.W. Köster, A.S. Forouhar, G. Acevedo-Bolton, S.E. Fraser, and M. Gharib,“Intracardiac fluid forces are an essential epigenetic factor for embryonic cardiogenesis,”Nature, 421, 172–177 (2003).
Fluid forces contribute to heart formation
<< < > >> B F R I Page 5
![Page 6: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/6.jpg)
Process Speed / Frequency
Microtubule growth 300-500nm/s
Cell migration (EC over fibroblasts) 20-50 μm/h
Cellular tra»cking 20-80 μm/min
(protein transp. by vesicle, . . . )
Chromosome dynamics > 0.5 μm/10 sec
Calcium signaling (sparks) 1 nm/s to 50 μm/sec
Blood flow mm/s
Heart beat 1-10 Hz
Beating ciliated cells 3-40 Hz
Speed of some Biological Processes
<< < > >> B F R I Page 6
![Page 7: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/7.jpg)
Migrating germ cells @ 6 frames/h
C. Readhead, M. Liebling18.5 dpc Tg(oct4::GFP) mouse.Grid: 50μm, 6 frames/h, over 6 hours
Blood circulation @ 12 frames/h
Liz Jones, Mary Dickinson8.5dpc Tg(ε-globin::GFP) mouse, 1 frame/5 minutes[Jones et al. (2002) Genesis 34, 228–235]
Cell migration/division Heart motion, blood flow
Speed 10 μm/s mm/s
Required frame rate 1–10 frames/s 100–200 frames/s
Moving at the Speed of Cells
<< < > >> B F R I Page 7
![Page 8: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/8.jpg)
Blood flow visualization@ 2 frames/s (confocal)
Liz Jones, Mary DickinsonTg(ε-globin:GFP) mouse, Zeiss LSM 5 PASCALTransmitted light / 488nm ex/ LP 505 em, 2 frames/s
@ 30 frames/s (video)
Liz Jones, Mary Dickinson
Insu»cient frame-rates introduce artifacts
<< < > >> B F R I Page 8
![Page 9: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/9.jpg)
Fluorescence: Reminder
<< < > >> B F R I Page 9
![Page 10: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/10.jpg)
From: http://www.olympusfluoview.com/theory/index.html
Confocal Microscopy Principle: Reminder
<< < > >> B F R I Page 10
![Page 11: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/11.jpg)
Adapted from: http://www.olympusfluoview.com/theory/confocalscanningsystems.html
Point Scanning
<< < > >> B F R I Page 11
![Page 12: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/12.jpg)
Line array detector
Point detectorConfocalPinhole
Confocal Slit
Point Scanning
Slit Scanning
MicroscopeObjective
MicroscopeObjective
FocusedLine
FocusedPoint
Making a Fast Scanning Confocal Microscope
<< < > >> B F R I Page 12
![Page 13: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/13.jpg)
Zeiss LSM 5 LIVE
<< < > >> B F R I Page 13
![Page 14: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/14.jpg)
Zeiss LSM 5 LIVEFast confocal microscopy
13
Beam path of the LSM 5 LIVE
1. Optical fibers2. Mirror3. Beam combiner4. Beam shaper5. AchroGate beam splitter6. Zoom optics7. Scanning mirror8. Scanning optics9. Objective lens
10. Specimen11. Secondary beamsplitter12. Detector- and pinhole optics13. Confocal pinhole14. Emission filters15. Detector
Parallel illumination/detection120 frames per s at 512×512
2D slice of zebrafish heart (60 fps)
M. Liebling, J. Vermot[38 hpf wildtype zebrafish, BODIPY FL C5-ceramide]
Parallel Acquisition for Increased Speed
<< < > >> B F R I Page 14
![Page 15: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/15.jpg)
4D Imaging via Gated Image Acquisition
<< < > >> B F R I Page 15
![Page 16: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/16.jpg)
Nongated Imaging Requires Synchronization
<< < > >> B F R I Page 16
![Page 17: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/17.jpg)
Method
Adjacent 2D slices of zebrafish heartBefore synchronization (raw data)
z1 z2
Mary Dickinson, Arian Forouhar
4D Imaging via Post-Acquisition Synchronization
<< < > >> B F R I Page 17
![Page 18: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/18.jpg)
Method
Adjacent 2D slices of zebrafish heartAfter synchronization
z1 z2
Mary Dickinson, Arian Forouhar
4D Imaging via Post-Acquisition Synchronization
<< < > >> B F R I Page 17
![Page 19: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/19.jpg)
Manual 4D Reconstruction
<< < > >> B F R I Page 18
![Page 20: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/20.jpg)
Limitations of manual registrationTedious, non-reproducible, error-prone.
ChallengesLarge data size, limited time, fluorescence imaging artifacts (bleaching,photon/detector noise, etc.).
RequirementsNo a priori information (electrocardiogram, etc.), robust (accurate andreproducible)
X Y Z Time Channels Depth Memory
512 512 128 512 4 16 bits 128GB
512 512 128 512 2 8 bits 32GB
256 256 64 256 1 8 bits 1 GB
256 256 64 128 1 8 bits 512 MB
Automatic Registration Challenges
<< < > >> B F R I Page 19
![Page 21: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/21.jpg)
Sequential z-acquisition:
z1
z1z2
xy
t
t
Measurement model:
Im(x, zk, t) =ZZZI(x′, z, t − sk)
PSF(x − x′, z − zk) dx′dz
for k = 1, . . . , Nz. Unknowns shifts sk .Assumptions:• Periodicity: |I(x, z, t)− I(x, z, t+T )| � Imax• Same period T at all depths• Acquisitions overlap: suppz(PSF) > Éz
Synchronization (time-registration):Error metric
|Im(x, z1, t) − Im(x, z2, t − s1,2)|2
z1
s
z2
z1
z2
t
1,2
4D Confocal Imaging of the Beating Heart
<< < > >> B F R I Page 20
![Page 22: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/22.jpg)
. . .with some help from astronomy
i + 1τ
i - 1τ
iτ
j+1τʼ
j-1τʼ
jτʼ
j+1τʼ
j-1τʼ
jτʼ
T’1
1
T’2
2
10
10
T
t
t
t
Original Sequence
Wrong Guess T’
Correct Guess T’
R. F. Stellingwerf, “Period determination using phase dispersion minimization,” Astrophysical Journal, 224(3),953–960 (1978)M. M. Dworetsky, “A period-finding method for sparse randomly spaced observations or how long is a piece ofstring,” Monthly Notices of the Royal Astronomical Society, 203(3), 917–924 (1983).
Finding the Period. . .
<< < > >> B F R I Page 21
![Page 23: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/23.jpg)
Mean square intensity di«erence
Qk,k′(s) =ZZ
R2
Z L0|Im(x, zk, t) − Im(x, zk′, t − s)|2 dt dx where s ∈ R
Periodicity implies:
Qk,k′(s) =ZZ
R2
Z L0|Im(x, zk, t)|2 + |Im(x, zk′, t − s)|2 dt dx
− 2ZZ
R2
Z L0Im(x, zk, t)Im(x, zk′, t − s) dt dx
= C − 2ZZ
R2
Z L0Im(x, zk, t)Im(x, zk′, t − s) dtj ız ℘
Correlation
dx.
Least-squares error minimization (≡ correlation maximization)
sk,k′ = mins=kT,k=1,...,Nt
Qk,k′(s).
Intensity-based Registration—Periodic Case
<< < > >> B F R I Page 22
![Page 24: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/24.jpg)
t
t
Intensity I(x,z ,t)1
Intensity I(x,z ,t)2
Correct Shift Maximizes Correlation
<< < > >> B F R I Page 23
![Page 25: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/25.jpg)
t
t
Intensity I(x,z ,t)1
Intensity I(x,z ,t)2
t
t
Correct Shift Maximizes Correlation
<< < > >> B F R I Page 23
![Page 26: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/26.jpg)
t
t
Intensity I(x,z ,t)1
Intensity I(x,z ,t)2
t
t
Shift
s1,2
Correlation
Correct Shift Maximizes Correlation
<< < > >> B F R I Page 23
![Page 27: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/27.jpg)
t
t
Intensity I(x,z ,t)1
Intensity I(x,z ,t)2
t
t
Shift
s1,2
Correlation
Correct Shift Maximizes Correlation
<< < > >> B F R I Page 23
![Page 28: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/28.jpg)
t
t
Intensity I(x,z ,t)1
Intensity I(x,z ,t)2
t
t
Shift
s1,2
Correlation
Correct Shift Maximizes Correlation
<< < > >> B F R I Page 23
![Page 29: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/29.jpg)
t
t
Intensity I(x,z ,t)1
Intensity I(x,z ,t)2
t
t
Shift
s1,2
Correlation
Correct Shift Maximizes Correlation
<< < > >> B F R I Page 23
![Page 30: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/30.jpg)
t
t
Intensity I(x,z ,t)1
Intensity I(x,z ,t)2
t
t
Shift
s1,2
Correlation
Correct Shift Maximizes Correlation
<< < > >> B F R I Page 23
![Page 31: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/31.jpg)
t
t
Intensity I(x,z ,t)1
Intensity I(x,z ,t)2
t
t
Shift
s1,2
Correlation
Correct Shift Maximizes Correlation
<< < > >> B F R I Page 23
![Page 32: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/32.jpg)
20 μm
Raw Data Wavelet Coefficients Data Reduction
Overcoming Fluorescence Imaging Artifacts
<< < > >> B F R I Page 24
![Page 33: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/33.jpg)
t t t
Original Wavelet Transform Data ReductionThreshold
Features:Cropping→ increase speed, save memoryRemove high pass bands, threshold→ robustness to photon / acquisition noiseRemove low pass band→ robustness to bleaching artifactsTime interpolation→ increase accuracy
M. Liebling, A.S. Forouhar, M. Gharib, S.E. Fraser, M.E. Dickinson, J. Biomedical Optics, 10 (5), 2005.
Thresholded Wavelet Coe»cient Synchronization
<< < > >> B F R I Page 25
![Page 34: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/34.jpg)
Relation between absolute shifts sk and relative shifts sk,k ′ :266666666666666664
1 0 0 0 0
1 −1 0 0 0
0 1 −1 0 0
0 0 1 −1 0
0 0 0 1 −11 0 −1 0 0
0 1 0 −1 0
0 0 1 0 −1
377777777777777775
j ız ℘A
0BBBBBBB∂
s1s2s3s4s5
1CCCCCCCA
j ız ℘t
=
266666666666666664
0
s1,2s2,3s3,4s4,5s1,3s2,4s3,5
377777777777777775
j ız ℘s
Weighted least-squares solution (via normal equations):
A†W†WAt = A†W†Ws
with weights W = diag(1, w1, w1, w1, w1, w1, w2, w2, w2).
Absolute Shift Determination
<< < > >> B F R I Page 26
![Page 35: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/35.jpg)
z1
z2
z3
z4
z1
z2
z3
z4
t
A Special Case. . .
<< < > >> B F R I Page 27
![Page 36: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/36.jpg)
4 Possible Reconstructions
<< < > >> B F R I Page 28
![Page 37: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/37.jpg)
. . . an ill-Posed Problem
<< < > >> B F R I Page 29
![Page 38: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/38.jpg)
Conversion from 2D+time to 3D+time is possible when:
a) Motion is homogeneous along z (→ hypothesis: PSF overlap).
b) Availability of supplementary knowledge:ECG, triggered/gated measurements, etc.
Shear is allowed!
z2
z1
z3
z2
z1
z3
Time
When is reconstruction possible?
<< < > >> B F R I Page 30
![Page 39: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/39.jpg)
Validation method:1. Random shifts definition2. Simulated data acquisition(random periodic deformation)3. Reconstruction4. Comparison
Average error of absolute shiftsε̄ = 0.31 ± 0.08 frames(Calculated over 100 random periodichomogeneous deformations40 frames, 2× time-oversampling)
⇒ Sub-frame accuracy
M. Liebling et al.,J. Biomed. Opt., 10(5), 2005.
Simulated original
Reconstruction
What is the accuracy?
<< < > >> B F R I Page 31
![Page 40: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/40.jpg)
Specific Imaging by Use of Transgenic Fish
<< < > >> B F R I Page 32
![Page 41: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/41.jpg)
<< < > >> B F R I Page 33
![Page 42: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/42.jpg)
Acquisition Model
Im(x, zk, t) =ZZZI [x′, z, τk(t)]h(x − x′, zk − z) dx′dz,
τk(t): unknown warping functions. h(x, z): Microscope point spread function(PSF) Hypothesis
|I [x, z, τ] − I [x, z, τ + T ]| � Imax.Objective criterion (absolute di«erence):
Qk,k ′,wk {w ′k} =Z L0
ZZR2|Im[x, zk, wk(τ)] − Im[x, zk ′ , wk ′ (τ)]|dxdτ.
Goal:Recover warping functions wk ′ (τ) for k
′ = {0, . . . , Nz − 1}\{k̄}.Approach:(a) Interpolation and oversampling of reference sequence⇒ discrete wk(τ)(b) Frame matching via dynamic programming
⇒ Reduce complexity from Oζ(Nr )
Ntηto O(NrNt).
Nonuniform temporal registration
<< < > >> B F R I Page 34
![Page 43: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/43.jpg)
0 10 20 30 40 50 60 70 80−1
−0.5
0
0.5
1
1.5
2
2.5
3
3.5
4ReferenceTest
Nonuniform Registration
<< < > >> B F R I Page 35
![Page 44: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/44.jpg)
0 10 20 30 40 50 60 70 80−1
−0.5
0
0.5
1
1.5
2
2.5
3
3.5
4ReferenceTestWarped
Nonuniform Registration
<< < > >> B F R I Page 35
![Page 45: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/45.jpg)
Nonuniform Dynamic Programming Registration
<< < > >> B F R I Page 36
![Page 46: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/46.jpg)
Nonuniform Dynamic Programming Registration
<< < > >> B F R I Page 36
![Page 47: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/47.jpg)
Nonuniform Dynamic Programming Registration
<< < > >> B F R I Page 36
![Page 48: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/48.jpg)
Nonuniform Dynamic Programming Registration
<< < > >> B F R I Page 36
![Page 49: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/49.jpg)
Nonuniform Dynamic Programming Registration
<< < > >> B F R I Page 36
![Page 50: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/50.jpg)
Nonuniform Dynamic Programming Registration
<< < > >> B F R I Page 36
![Page 51: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/51.jpg)
Slices before synchronizationz = 0 μm z = 10 μm z = 20 μm z = 30 μm z = 40 μm
Slices after synchronization
M. Liebling, J. Vermot [38 hpf wildtype zebrafish, BODIPY FL C5-ceramide]M. Liebling, J. Vermot, A.S. Forouhar, M. Gharib, M.E. Dickinson, S.E. Fraser, Proc. ISBI’06, in press.
Robust and Reproducible Synchronization
<< < > >> B F R I Page 37
![Page 52: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/52.jpg)
Before synchronization After synchronization
M. Liebling, J. Vermot [38 hpf wildtype zebrafish, BODIPY FL C5-ceramide]M. Liebling, J. Vermot, A.S. Forouhar, M. Gharib, M.E. Dickinson, S.E. Fraser, Proc. ISBI’06, in press.
Automatic synchronization allows 4D reconstruction
<< < > >> B F R I Page 38
![Page 53: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/53.jpg)
M. Liebling, J. Vermot [38 hpf wildtype zebrafish, BODIPY FL C5-ceramide]
Synchronized dataset is suited for 3D rendering
<< < > >> B F R I Page 39
![Page 54: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/54.jpg)
0 ms 100 ms 200ms 300 ms 400 ms
AA A A A
VV VVV
0 ms 75 ms
100 μm
150ms 225 ms 300 ms
AA
A A A
V VV
VV
100 μm
Heart Cycle @ 48hpf, gata1::GFP Zebrafish
<< < > >> B F R I Page 40
![Page 55: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/55.jpg)
M. Liebling, A.S. Forouhar, M. Gharib, S.E. Fraser, M.E. Dickinson, J. Biomedical Optics, 10 (5), 2005.
Microscopic Heart
<< < > >> B F R I Page 41
![Page 56: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/56.jpg)
Fast 3D+time imaging is possiblein the living embryonic heart
Automatic reconstruction procedureallows quantitative measurements
in a large number of fish
Automated Reconstruction:• Robust to confocal microscopy artifacts• Adapted to large data size• Accuracy validated in silico and in vivo• Allows for systematic and quantitative measurements
Summary
<< < > >> B F R I Page 42
![Page 57: Imaging the Developing Embryonic Heart: Combining Fast ...helper.ipam.ucla.edu/publications/hm2006/hm2006_6262.pdf · R. F. Stellingwerf, “Period determination using phase dispersion](https://reader034.vdocuments.net/reader034/viewer/2022042121/5e9b60cd4bbfe774be72afda/html5/thumbnails/57.jpg)
Contact: Michael Liebling, http://www.its.caltech.edu/~liebling/
CollaborationsCarl Zeiss, Advanced Imaging MicroscopyShuo Lin, UCLA [Tg(gata1::GFP)]Huai-Jen Tsai, Nat’l Taiwan U. [Tg(cmlc2::GFP)]Colophon4D processing & rendering: Matlab, Imaris (Bitplane AG)Postprocessing:ImageMagick, GraphicConverter, pdfLATEXFundingHuman Frontiers, Center for Bioengineering for the Explorationof Space, American Heart Assoc., NSF, NIHSwiss National Science Foundation
Arian S. ForouharMory GharibScott E. FraserMary E. DickinsonSonia CollazoAnna HickersonLiz JonesAbbas MoghaddamCarol ReadheadJulien VermotChris Waters
Index Studying the Developing HeartZebrafish EmbryosGenetic and Epigenetic FactorsSpeed Biological Processes Mov-ing at the Speed of CellsInsu»cient frame-rate artifactsFluorescence: ReminderConfocal Microscopy ReminderPoint ScanningPoints vs line scanZeiss LSM 5 LIVE
Parallel AcquisitionGated 4D ImagingNongated 4D Imaging4D ImagingManual 4D ReconstructionAutomatic Registration ChallengesProblem definitionFinding the Period. . .Intensity-based RegistrationCorrect Shift Maximizes CorrelationWavelets and Fluorescence
Wavelet SynchronizationAbsolute Shift DeterminationA Special Case. . .When is the reconstruction possible?What is the accuracy?cmlc2 3DDev. of Zfish Heart (cmlc2)Nonuniform temporal registrationDP exampleDP RegistrationBodipy Galery
Bodipy SliceBodipy 3DHeart Cycle @ 48hpfDev. of Zfish Heart (gata1)Volume MeasurementsPeristaltic vs Impedance PumpingImpedance Pump: Mechanical ModelEarly embryonic heart tubeIs pump peristaltic?Summary
Acknowledgments