STANDARDS COMPLIANCE Safety/Environmental
Shock
Vibration
RoHS, UL810a*, Chinese RoHS, IP67
IEC 60068-2-27 (TA1@25g), ISO 16750-3 (4.2.2)
ISO 16750-3 (Table 12)
www.ioxus.com | [email protected]©2020 Ioxus, Inc 200401
FEATURESMade in USALarge diameter end terminals Integrated heat sinkNon-conductive end plates Highly configurable w/6 T-slots Flexible mounting, any orientation IP6765°C Capability
APPLICATIONSHigh powerHigh rate cyclingHigh cycle life (>1,000,000 cycles) Low maintenance
MARKETSTransportation subsystemEngine startingRegen energy captureGrid/Power correctionUPS/Ride through powerWind turbine pitch control Hybrid energy storage
iMOD X-SERIES®
SMART POWER
Corporate HeadquartersNorth American Sales
18 Stadium Circle Oneonta, NY 13820, USA
Toll Free: [email protected]
TEL: 607-441-3500FAX: 607-433-9014
Ioxus Japan Co. LTD
1381-1 OkamotochoKusatsu-city, Shiga Pref
525-0044, [email protected]
TEL : +81-77-569-5106FAX: +81-77-569-5168
*Shown with optional CAN MonitoringModule
* = Family of X-Series expected to pass, as 96V/83F passed UL certification
ELECTRICAL\PART NUMBER iMOD016V200A23 iMOD032V100A23 iMOD048V066A23 iMOD064V050A23 iMOD080V040A23 iMOD096V033A23 iMOD112V028A23 iMOD128V025A23
Capacitance (F) [Min/Nom] 192/200 96/100 63/66 48/50 38/40 31/33 26/28 24/25Voltage (Rated/Surge) [VR/VS] 16.2/17.1 32.4/34.2 48.6/51.3 64.8/68.4 81.0/85.5 97.2/102.6 113.4/119.7 129.6/136.8DC ESR 10ms (mΩ) [Nom/Max] 1.6/1.9 3.2/3.8 4.8/5.7 6.4/7.6 8.1/9.6 9.7/11.5 11.3/13.4 12.9/15.3IEC DC ESR (mΩ) [Nom/Max] 2.5/3.0 5.0/6.1 7.5/9.1 10.0/12.2 12.6/15.3 15.1/18.3 17.6/21.4 20.1/24.4AC ESR(mΩ 1kHz) [Nom/Max] 1.8/2.2 3.3/4.1 4.7/5.8 6.2/7.7 7.8/9.6 9.4/11.6 10.9/13.5 12.5/15.4Hi Pot Test Voltage 5000VAC
UL Max Operational Voltage (per UL810A) 2000VDC (per series string)
CYCLING (Calculated Values)Continuous Current (A) [20°Rise] Test Data Available for some models. Contact Ioxus
Current, Short Circuit (A) 10,000Current, Peak [1s] (A) 1,200THERMAL (Reference)Operational / Storage Range (°C)
Resistance, Thermal (°C/W) [RTH]ENERGY (Reference / Calculated using nominal values)
EMAX (Whr) [Min/Nom] 6.9/7.2 13.9/14.5 20.6/21.6 27.9/29.1 34.6/36.4 40.6/43.3 46.4/50.0 55.9/58.3
PHYSICAL (Nominal Values)H (mm) 224W (mm) 147L (mm) 117 204 284 365 445 526 606 687Mass (kg) 4.3 7.6 11.0 14.4 17.8 21.1 24.5 27.9Volume (L) 3.9 6.7 9.4 12.0 14.7 17.3 20.0 22.6Terminal Fastener Size / Max Torque M8/20Nm & M10/30Nm
LIFE (EOL Criteria) [Capacitance/IEC DC ESR] *Life is a provisional valueDC (10 Yr, 25°C, @VR) [F/mΩ]Endurance (2000hr, 65°C, @VR) [F/mΩ]
Storage (2 yr, 25°C, @ 0V) [F/mΩ]
Cycle (1M Cyc, 25°C, @ VR-VR/2) [F/mΩ]
>160/<6>160/<6>180/4.5>160/<6
>80/<12.2>80/<12.2>90/<9.1>80/<12.2
>52/<18.2>52/<18.2>58/<13.6>52/<18.2
>40/<24.4>40/<24.4>44/<18.3>40/<24.4
>32/<30.6>32/<30.6>36/<22.9>32/<30.6
>26/<36.6>26/<36.6>28/<27.4>26/<36.6
>22/<42.8>22/<42.8>24/<32.1>22/<42.8
>20/<48.8>20/<48.8>22/<36.6>20/<48.8
1200F BASED PRODUCT SPECIFICATIONS
www.ioxus.com | [email protected]©2020 Ioxus, Inc 200401
ADDITIONAL TECHNICAL INFORMATIONProduct specification test and calculation methods are available:
Ioxus Notes on Datasheet Specifacations Ioxus Test Proceedures for Customer Evaluations
HOW TO ORDERBASE PART NUMBER MONITORING OPTIONS
iMODvvvVcccA23 + -01B Analog Temperature
-03B CAN
-40 to 65 °C / -40 to 70 °CTest Data Available for some models. Contact Ioxus
ELECTRICAL\PART NUMBER iMOD016V333A23 iMOD032V166A23 iMOD048V0111A23 iMOD064V083A23 iMOD080V066A23 iMOD096V055A23 iMOD112V047A23 iMOD128V041A23
Capacitance (F) [Min/Nom] 319/333 159/166 106/111 79/83 63/66 52/55 45/47 39/41Voltage (Rated/Surge) [VR/VS] 16.2/17.1 32.4/34.2 48.6/51.3 64.8/68.4 81.0/85.5 97.2/102.6 113.4/119.7 129.6/136.8DC ESR 10ms (mΩ) [Nom/Max] 1.3/1.8 2.6/3.6 3.9/5.4 5.2/7.2 6.6/9.0 7.9/10.8 9.2/12.6 10.5/14.4IEC DC ESR (mΩ) [Nom/Max] 1.7/2.1 3.4/4.2 5.2/6.3 6.9/8.4 8.7/10.5 10.4/12.6 12.1/14.7 13.9/16.8AC ESR(mΩ 1kHz) [Nom/Max] 1.5/1.9 2.8/3.6 4.0/5.1 5.3/6.8 6.6/8.4 7.9/10.1 9.2/11.8 10.6/13.5
Hi Pot Test Voltage 5000VAC
UL Max Operational Voltage (per UL810A) 2000VDC (per series string)
CYCLING (Calculated Values)Continuous Current (A) [20°Rise]Current, Short Circuit (A) 12,400Current, Peak [1s] (A) 1,900THERMAL (Reference)Operational / Storage Range (°C)
Resistance, Thermal (°C/W) [RTH]ENERGY (Reference / Calculated using nominal values)EMAX (Whr) [Min/Nom] 11.6/12.1 23.1/24.2 34.7/36.4 46.0/48.4 57.4/60.1 68.2/72.1 80.3/83.9 90.9/95.6PHYSICAL (Nominal Values)H (mm) 224W (mm) 147L (mm) 133 241 349 457 565 673 781 889Mass (kg) 5.5 10.0 14.6 19.1 23.7 28.3 32.8 37.4Volume (L) 4.9 8.5 12.0 15.6 19.2 22.7 26.3 29.8Terminal Fastener Size / Max Torque M8/20Nm & M10/30Nm
LIFE (EOL Criteria) [Capacitance/IEC DC ESR] *Life is a provisional valueDC (10 Yr, 25°C, @VR) [F/mΩ]Endurance (2000hr, 65°C, @VR) [F/mΩ]
Storage (2 yr, 25°C, @ 0V) [F/mΩ]
Cycle (1M Cyc, 25°C, @ VR-VR/2) [F/mΩ]
>266/<4.2>266/<4.2>298/<3.1>266/<4.2
>132/<8.4>132/<8.4>148/<6.3>132/<8.4
>88/<12.6>88/<12.6>98/<9.4>88/<12.6
>66/<16.8>66/<16.8>74/<12.6>66/<16.8
>52/<21.0>52/<21.0>58/<15.7>52/<21.0
>44/<25.2>44/<25.2>48/<18.9>44/<25.2
>36/<29.4>36/<29.4>42/<22.0>36/<29.4
>32/<33.6>32/<33.6>36/<25.2>32/<33.3
2000F BASED PRODUCT SPECIFICATIONS
www.ioxus.com | [email protected]©2020 Ioxus, Inc 200401
ADDITIONAL TECHNICAL INFORMATIONProduct specification test and calculation methods are available:
Ioxus Notes on Datasheet Specifacations Ioxus Test Proceedures for Customer Evaluations
HOW TO ORDERBASE PART NUMBER MONITORING OPTIONS
iMODvvvVcccA23 + -01B Analog Temperature
-03B CAN
Test Data Available for some models. Contact Ioxus
-40 to 65 °C / -40 to 70°CTest Data Available for some models. Contact Ioxus
ELECTRICAL\PART NUMBER iMOD016V500A23 iMOD032V250A23 iMOD048V166A23 iMOD064V125A23 iMOD080V100A23 iMOD096V083A23
Capacitance (F) [Min/Nom] 480/500 240/250 159/166 120/125 96/100 79/83Voltage (Rated/Surge) [VR/VS] 16.2/17.1 32.4/34.2 48.6/51.3 64.8/68.4 81.0/85.5 97.2/102.6DC ESR 10ms (mΩ) [Nom/Max] 1.2/1.6 2.4/3.3 3.6/5.0 4.8/6.7 6.0/8.4 7.2/10.0IEC DC ESR (mΩ) [Nom/Max] 1.5/1.9 3.0/3.7 4.5/5.5 6.0/7.4 7.5/9.3 9.0/11.1AC ESR(mΩ 1kHz) [Nom/Max] 1.4/1.8 2.6/3.4 3.6/4.7 4.8/6.3 6.0/7.8 7.2/9.4
Hi Pot Test Voltage 5000VAC
UL Max Operational Voltage (per UL810A) 2000VDC (per series string)
CYCLING (Calculated Values)Continuous Current (A) [20°Rise]Current, Short Circuit (A) 13,500Current, Peak [1s] (A) 2,500THERMAL (Reference)Operational / Storage Range (°C)
Resistance, Thermal (°C/W) [RTH]ENERGY (Reference / Calculated using nominal values)EMAX (Whr) [Min/Nom] 17.4/18.2 34.9/36.4 52.1/54.4 69.9/72.9 87.4/91.1 103.6/108.9PHYSICAL (Nominal Values)H (mm) 224W (mm) 147L (mm) 165 309 453 597 741 885Mass (kg) 7 12 18 24 29 35Volume (L) 5.9 10.9 15.6 20.3 25.1 29.8Terminal Fastener Size / Max Torque M8/20Nm & M10/30Nm
LIFE (EOL Criteria) [Capacitance/IEC DC ESR] *Life is a provisional valueDC (10 Yr, 25°C, @VR) [F/mΩ] >66/<22.2Endurance (2000hr, 65°C, @VR) [F/mΩ]
Storage (2 yr, 25°C, @ 0V) [F/mΩ]
Cycle (1M Cyc, 25°C, @ VR-VR/2) [F/mΩ]
>400/<3.7>400/<3.7>450/<2.7>400/<3.7
>200/<7.4>200/<7.4>224/<5.5>200/<7.4
>132/<11>132/<11>148/<8.2>132/<11
>100/<14.8>100/<14.8>112/<11.1>100/<14.8
>80/<18.6>80/<18.6>90/<13.9>80/<18.6
>66/<22.2>74/<16.6>66/<22.2
3000F BASED PRODUCT SPECIFICATIONS
www.ioxus.com | [email protected]©2020 Ioxus, Inc 200401
ADDITIONAL TECHNICAL INFORMATIONProduct specification test and calculation methods are available:
Ioxus Notes on Datasheet Specifacations Ioxus Test Proceedures for Customer Evaluations
HOW TO ORDERBASE PART NUMBER MONITORING OPTIONS
iMODvvvVcccA23 +-01B Analog Temperature
-03B CAN
*Shown with optional CANMonitoring Modules and acces-
sories to facilitate mouting in a standard 19” Rack. Please
contact your representative with questions
Test Data Available for some models. Contact Ioxus