implant impression techniques comparative review: … in the treatment of the edentulous jaw....

2
Dental Tribune U.S. Edition | August 2012 A10 Implant impression techniques comparative review: Transfer impression versus direct abutment level By Zvi Fudim, DDS, president, Stomatotech The inaccuracy in dental implant impres- sion is a vast and unsolved problem. It is so serious that the high rate of osteointegra- tion of the majority of implants is absolute- ly meaningless. Knowing that traditional transfer impression techniques seldom deliver a passive fit of a framework means that most bridges will end up with a failure (Fig. 1). Different studies show that transfer tech- nique is almost four times worse than the official requirement. Therefore, besides the mechanical issue, it is also a patient’s right to know that impression transfer method is extremely inaccurate, and requires at least a warning and a legal consent. Patients are often misled by widely accepted sources that state: “Success rates of dental implants vary, de- pending on where in the jaw the implants are placed but, in general, dental implants have a success rate of up to 98 percent. With proper care (see below), implants can last a lifetime” ( WebMd.com). Numerous in-vitro studies have exam- ined implant restoration accuracy. There is no doubt about the fact that the transfer impression is to blame for the misfit of the framework, but what exactly causes the distortion has not yet been pointed out. What is wrong in the transfer impression? The first problem is that the transfer, which is mechanically caught in the impression material (such as PVS), does not become an integral part of the impression. In fact, it can be easily moved. However, due to the friction between the surfaces of the trans- fer and the impression material, it does not return back to its original position (Figs. 2, 2a, 2b). That displacement cannot be avoid- ed when the technician engages analogs into the impression. In other words, forces in form of torque or pressure dislocate and mobilize irreversibly the imbedded im- plant parts. Fastening in the screw into the analog should be done avoiding any contact with the tray; however, that cannot be always guaranteed. The shift of the transfer can take place even due to the gravity forces of the impression tray, especially in the molar areas. A tray that weighs 100 grams gener- ates in the molar area a torque of 5.8 Ncm by only its own weight; that`s enough to ro- tate the transfer. The polyether impression materials are characterized by a serious amount of expansion, making the transfers lose and mobile in the impression (Figs. 3, 3a, 3b). The implant manufacturers should indicate that polyether impression materi- als are not suitable for the techniques using impression transfers. Splinting transfers with acrylic resins may lead to displacement of the transfers due to the shrinkage of the acrylic materi- als. Even a splinted complex of impression transfers does not become an integral part of the impression. The second problem is due to the uneven amount of the stone around the analog. The expansion of the dental stone during its setting causes a se- rious inclination of the abutment from its original position. The third problem is also related to the dental stone expansion. Un- like the stone, the analog does not have any expansion. The analog becomes lose and mobile. Gripping firmly a one-piece analog with a hemostat, one can see with a naked eye how it rotates in the model around its own axis. (Fig.4, 4a) Almost always, e sectioning of an implant stone model is very difficult to perform be- cause of the presence of the hard steel ana- logs in the body of the model. Additionally, a small amount of the dental stone around the analogs often leads to breakage of the die and requires either a redo of the dental model or working on an unsectioned mod- el. These difficult working conditions pre- vent precise fabrication of the restoration. Implant manufacturers have invested a lot of resources in the implant improve- ment but very little in the improvement of the impression accuracy. Many dentists become so frustrated by the results of the implant restoration that they stop restor- ing implants and refer the clients to prosth- odontists. Finally, more and more dentists today have come to the conclusion that a simple direct impression of the abutment is much better than the traditional transfer impres- sion. The accuracy of the PVS material is very high; it has high volumetric stability and a good resistance for tearing. Addition- ally the PVS by its slight rate of shrinkage can partially compensate the expansion of the dental stone and with aid of a rigid impression tray provides fabrication of ac- curate restoration. The main concern with the direct impression is the abutment’s sub gingival area registration. In 2008 JADA Dr. Vincent Bennani published a review INDUSTRY CLINICAL Fig. 1: Following a misfit, an implant transversal breakage is observed. Photos/ Provided by Zvi Fudim, DDS Fig. 2: An open tray transfer impression with engaged analog. Fig. 2a: Shows alignment of the analog with the rest of the impression. Fig. 2b: Following torque there is misalign- ment of the analog. called Gingival retraction techniques for implants versus teeth 4 . Bennani covered most gingival retraction means for natural teeth and discussed the possibility of ap- ply them in the impression of the implant restoration. His conclusion was that there is no existing device or method for gingival retraction that practically can be used for direct impression of the implant abutment. Aluminum Chloride Expasy™ was re- cently tested for use with the titanium endosseous implants and was found as a harmful material for the polished surfaces of the implant and implant parts. 1 Bicon Implants™ uses oversized healing abut- ments or custom oversized temporary abutments to expand the surrounding tis- sue. This method has little predictability because the rebound of the tissue varies from patient to patient. Recently, a Canadian company, Stomato- tech, came up with a simple idea to retract the gingival tissue using a disposable plas- tic collar that is inserted on the apical end of the abutment before the abutment is en- gaged to the implant (Fig. 5). Following the abutment`s engagement to the implant, the plastic collar is found be- tween the apical part of the abutment and the gingival soft tissue (Fig. 6). Shortly after the removal of the impression from the mouth, the plastic collar is pulled out and removed permanently. The plastic collar creates a perfect gingi- val retraction with a valve factor prevent- ing the liquids from contaminating the area of the finish line of the abutment. It is undeniable that the plastic collar eliminates the need of the impression transfer and the analog. However, the main advantage of that device is the fact that it does not impact the accuracy of the final restoration (Fig. 7). Fig. 3: Astratech polyether close tray impression. Fig. 3a: Following torque there is misalign- ment of the line on the analog. Fig. 3b: Polyether close tray impression presents a gap between the transfer and the rest of the impression. Fig. 4: An MIS one-piece analog. Stone model was glued on a cardboard. The head of the analog was fastened tightly by a hemostat. Significant mobility of the analog is always observed. Fig. 4a A line was traced next to the haemostat's handle. An evident analog movement is clearly observed. (The photo was taken from the same angle.) Fig. 5: G-Cuff device installed on the abutments. Fig. 6: Removal of the G-Cuff without unscrewing the abutment. Fig. 7: Final impression Implant Direct Legacy.

Upload: tranque

Post on 11-Mar-2018

223 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: Implant impression techniques comparative review: … in the treatment of the edentulous jaw. IntJOralSurg1981;10:387–416AdellR, Lekholm U, Rockler B, Branemark. 13. The longitudinal

Dental Tribune U.S. Edition | August 2012A10

Implant impression techniques comparative review: Transfer impression versus direct abutment levelBy Zvi Fudim, DDS, president, Stomatotech

The inaccuracy in dental implant impres-sion is a vast and unsolved problem. It is so serious that the high rate of osteointegra-tion of the majority of implants is absolute-ly meaningless. Knowing that traditional transfer impression techniques seldom deliver a passive fit of a framework means that most bridges will end up with a failure (Fig. 1).

Different studies show that transfer tech-nique is almost four times worse than the official requirement. Therefore, besides the mechanical issue, it is also a patient’s right to know that impression transfer method is extremely inaccurate, and requires at least a warning and a legal consent. Patients are often misled by widely accepted sources that state:

“Success rates of dental implants vary, de-pending on where in the jaw the implants are placed but, in general, dental implants have a success rate of up to 98 percent. With proper care (see below), implants can last a lifetime” (WebMd.com).

Numerous in-vitro studies have exam-ined implant restoration accuracy. There is no doubt about the fact that the transfer impression is to blame for the misfit of the framework, but what exactly causes the distortion has not yet been pointed out.

What is wrong in the transfer impression?The first problem is that the transfer, which is mechanically caught in the impression material (such as PVS), does not become an integral part of the impression. In fact, it can be easily moved. However, due to the friction between the surfaces of the trans-fer and the impression material, it does not return back to its original position (Figs. 2, 2a, 2b). That displacement cannot be avoid-

ed when the technician engages analogs into the impression. In other words, forces in form of torque or pressure dislocate and mobilize irreversibly the imbedded im-plant parts.

Fastening in the screw into the analog should be done avoiding any contact with the tray; however, that cannot be always guaranteed. The shift of the transfer can take place even due to the gravity forces of the impression tray, especially in the molar areas. A tray that weighs 100 grams gener-ates in the molar area a torque of 5.8 Ncm by only its own weight; that̀ s enough to ro-tate the transfer. The polyether impression materials are characterized by a serious amount of expansion, making the transfers lose and mobile in the impression (Figs. 3, 3a, 3b). The implant manufacturers should indicate that polyether impression materi-als are not suitable for the techniques using impression transfers.

Splinting transfers with acrylic resins may lead to displacement of the transfers due to the shrinkage of the acrylic materi-als. Even a splinted complex of impression transfers does not become an integral part of the impression. The second problem is due to the uneven amount of the stone around the analog. The expansion of the dental stone during its setting causes a se-rious inclination of the abutment from its original position. The third problem is also related to the dental stone expansion. Un-like the stone, the analog does not have any expansion. The analog becomes lose and mobile. Gripping firmly a one-piece analog with a hemostat, one can see with a naked eye how it rotates in the model around its own axis. (Fig.4, 4a)

Almost always, e sectioning of an implant stone model is very difficult to perform be-cause of the presence of the hard steel ana-logs in the body of the model. Additionally, a small amount of the dental stone around the analogs often leads to breakage of the die and requires either a redo of the dental model or working on an unsectioned mod-el. These difficult working conditions pre-vent precise fabrication of the restoration.

Implant manufacturers have invested a lot of resources in the implant improve-ment but very little in the improvement of the impression accuracy. Many dentists become so frustrated by the results of the implant restoration that they stop restor-ing implants and refer the clients to prosth-odontists.

Finally, more and more dentists today have come to the conclusion that a simple direct impression of the abutment is much better than the traditional transfer impres-sion. The accuracy of the PVS material is very high; it has high volumetric stability and a good resistance for tearing. Addition-ally the PVS by its slight rate of shrinkage can partially compensate the expansion of the dental stone and with aid of a rigid impression tray provides fabrication of ac-curate restoration. The main concern with the direct impression is the abutment’s sub gingival area registration. In 2008 JADA Dr. Vincent Bennani published a review

INDUSTRY CLINICAL

Fig. 1: Following a misfit, an implant transversal breakage is observed. Photos/Provided by Zvi Fudim, DDS

Fig. 2: An open tray transfer impression with engaged analog.

Fig. 2a: Shows alignment of the analog with the rest of the impression.

Fig. 2b: Following torque there is misalign-ment of the analog.

called Gingival retraction techniques for implants versus teeth4. Bennani covered most gingival retraction means for natural teeth and discussed the possibility of ap-ply them in the impression of the implant restoration. His conclusion was that there is no existing device or method for gingival retraction that practically can be used for direct impression of the implant abutment.

Aluminum Chloride Expasy™ was re-cently tested for use with the titanium endosseous implants and was found as a harmful material for the polished surfaces of the implant and implant parts.1 Bicon Implants™ uses oversized healing abut-ments or custom oversized temporary abutments to expand the surrounding tis-sue. This method has little predictability because the rebound of the tissue varies from patient to patient.

Recently, a Canadian company, Stomato-tech, came up with a simple idea to retract the gingival tissue using a disposable plas-tic collar that is inserted on the apical end of the abutment before the abutment is en-gaged to the implant (Fig. 5).

Following the abutment̀ s engagement to the implant, the plastic collar is found be-tween the apical part of the abutment and the gingival soft tissue (Fig. 6). Shortly after the removal of the impression from the mouth, the plastic collar is pulled out and removed permanently.

The plastic collar creates a perfect gingi-val retraction with a valve factor prevent-ing the liquids from contaminating the area of the finish line of the abutment.

It is undeniable that the plastic collar eliminates the need of the impression transfer and the analog. However, the main advantage of that device is the fact that it does not impact the accuracy of the final restoration (Fig. 7).

Fig. 3: Astratech polyether close tray impression.

Fig. 3a: Following torque there is misalign-ment of the line on the analog.

Fig. 3b: Polyether close tray impression presents a gap between the transfer and the rest of the impression.

Fig. 4: An MIS one-piece analog. Stone model was glued on a cardboard. The head of the analog was fastened tightly by a hemostat. Significant mobility of the analog is always observed.

Fig. 4a A line was traced next to the haemostat's handle. An evident analog movement is clearly observed. (The photo was taken from the same angle.)

Fig. 5: G-Cuff device installed on the abutments.

Fig. 6: Removal of the G-Cuff without unscrewing the abutment.

Fig. 7: Final impression Implant Direct Legacy.

Page 2: Implant impression techniques comparative review: … in the treatment of the edentulous jaw. IntJOralSurg1981;10:387–416AdellR, Lekholm U, Rockler B, Branemark. 13. The longitudinal

Dental Tribune U.S. Edition | August 2012 A11

The greatest advantage is for optical im-pression users, because it allows scanning the abutment exactly the same way as a natural tooth. The digital impression is an extremely accurate method for taking im-pressions, and it is gaining its place in the dental general practice very fast. Still, its use in implant prosthodontics is limited.

A comparative study by J. B. Da Costa31 published in JOD, shows that there is no dif-ference between direct oral scanning and indirect scanning of a stone model from PVS impression, which confirms the high accuracy of both methods.

SummaryThe passive fit of the prosthetic framework is extremely important, especially for lon-gevity of an implant. Every implant, even the cheapest one, can last many years in the patient’s mouth if only it is correctly loaded and properly restored. Lack of the passive fit usually leads to serious bone loss and implant failure.

The practitioner has to do everything possible to keep the restoration in the zone of 10 µm of the marginal fit. An implant, unlike a natural tooth, does not have peri-odontal mechanism that gives the natural tooth a resilience of 50-80 µm.

Splinting as many crowns as possible di-vides evenly the load between the implants but can compromise the passivity due to the poor accuracy. To achieve 10 µm level of accuracy, every single negative cause should be eliminated from the impression procedure.

The only recipe for implant-supported restoration success is an accurate impres-sion. Currently, the alternative to the trans-fer impression is the silicon or optical direct impression of the abutment with G-Cuff™ by Stomatotech or with an optical impres-sion with an aid of scanable bodies.

These two methods deliver a substantial passive fit that assures longevity of the im-plants and of the whole restoration.

References1. Effectofacordlessretractionpastemate-

rialonimplantsurfaces:aninvitrostudy.Yin-Szu (Madison) Chang, Vincent Ben-nani,AndrewTawse-Smith,LizGirvan.

2. Bam Distortion and Biomechanics of Im-plant Supported Prostheses. C.F. Boshoff,D.G.HowesandC.

3. Accuracy of the implant impression ob-tained from different impression materi-alsandtechniques:review.D.R.Prithviraj,MaleshL.Pujari,PoojaGarg,D.P.Shruthi.

4. Gingival Retraction Techniques for Im-plants Versus Teeth: Current Status. Vin-centBennani,DonaldSchwassandNicho-lasChandlerJADA2008;139;1354–1363.

5. Accuracy of five implant impressiontechnique:Effect of splinting materialsand methods. Sang-Jik Lee, DDS, MSc,Sung-Bum Cho, DDS, MSc,Lee Yeon HabDental Clinic, Daegu, Plant Dental Clinic,Changwon,Korea.

6. Comparativeaccuracyofthesplintedandunsplinted impression methods for inter-nal connection. Jung-Han Choi, DDS.,Chang-WheKim,DDS.,MSD,PhD.,Kyung-SooJang,DDS,MSD.,PhD.,Young-JunLim,DDS,MSD,PhD.

7. Biomechanical Behavior of Oral Soft Tis-sues. Selda Goktas, John J. Dmytryk, andPeterS.McFetridge.

8. Implantcastaccuracyasafunctionofim-pressiontechniquesandimpressionmate-rial viscosity. Mary p. Walker, DDS, PhD,DaveRaise,BlakeBorello.

9. Tissue-integrated prostheses. Osseointe-grationinclinicaldentistry.BranemarkPI,ZarbGA,AlbrektssonTChicago:Quintes-sence;1985.

10. Accuracyofimpressionandpouringtech-niquesforanimplant-supportedprosthe-sis.Del'AcquaMA,Arioli-FilhoJN,Compa-gnoniMA,MolloFdeAJr.

11. Accuracy of polyether vs. plaster impres-sions for long-span implant supported

prosthesis.VonBerg,GeorgeBotha.12. A 15-year study of osseointegrated im-

plantsinthetreatmentoftheedentulousjaw.IntJOralSurg1981;10:387–416AdellR,LekholmU,RocklerB,Branemark.

13. The longitudinal clinical effectiveness ofosseointegrateddentalimplantsinanteri-or partially edentulous patients. Int JProsthodont 1993;6:180–188. Zarb GA,Schmitt.

14. Forces and moments on Branemark im-plants. Int J Oral Maxillofac Implants1989;4:241–247.RangertB,JemtT,JorneusL.

15. In vivo measurements of precision of fitinvolvingimplant-supportedprosthesesinthe edentulous jaw. Int J Oral MaxillofacImplants1996;11:151–158.JemtT.

16. TheSignificanceOfPassiveFrameworkFitInImplant Prosthodontics: CurrentStatus.Saime Sahin, DDS, PhD, Murat C.Cehreli,DDS,PhD.

17. Evaluation of the accuracy of three tech-niques used for multiple implant abut-ment impressions. J Prosthet Dent2003;89:186–192.VigoloP,MajzoubZ,Cor-dioliG.

18. Comparativeanalysisof4impressiontech-niques for implants. Implant Dent 2007;16:187–194.CabralLM,GuedesCG.

19. Osseointegration and its experimentalbackground. J Prosthet Dent 1983;50:399–410.BranemarkPI.

20. Inaccurate fit of implant superstructures.Part 1: Stresses generated on the super-structurerelativetothesizeoffitdiscrep-ancy.IntJProsthodont1995;8:511–516.Mill-ingtonND,LeungT.

21. Prosthesismisfitandmarginalbonelossinedentulous implant patients. Int J OralMaxillofacImplants1996;11:620–625.JemtT,BookK.

22. Accuracyofimplant-supportedprosthesesintheedentulousjaw:analysisofprecisionof fit between cast goldalloy frameworksandmastercastsbymeansofa three-di-mensional photogrammetric technique.ClinOralImplantsRes1995;6:172–180.JemtT,LieA.

23. Polymerization shrinkage of index andpattern acrylic resins. J Prosthet Dent1990;64:684–688.MojonP,OberholzerJP,MeyerJM,BelserUC.

24. ANSI-ADASpecificationNo.25Dentalgyp-sum products. Chicago: American dentalassociation council on dental materialsandequipment.2000.

25. Prefabricated acrylic resin bars for splint-ing implant transfer copings. J Prosthet

Dent2000;84:108–110.DumbrigueHB,Gu-runDC,JavidNS.

26. Accuracy of implant impression splintedtechniques:effectofsplintingmaterial.IntJOralMaxillofacImplants1999;14:885–888.AssifD,NissanJ,VarsanoI,SingerA.

27. Impressiontechniqueforpartiallyedentu-lous patients. J Prosthet Dent 2002;88:103–104. Nissan J, Barnea E, Krauze E,AssifD.

28. An implant impression technique using aplaster splinting index combined with asilicone impression. J Prosthet Dent2004;92:575–577.185.EidN.

29. Accuracyoffive implant impressiontech-nique: effect of splinting materials andmethods Adv Prosthodont 2011;3:177–185.LeeSJetal.

30. EvaluationofDifferentMethodsofOpticalImpressionMakingontheMarginalGapofOnlays Created with CEREC 3D. OperativeDentistry: May 2010, Vol. 35, No. 3, pp.324–329.J.B.daCosta,F.Pelogia,B.Hage-dorn,andJ.L.Ferracane(2010).

31. Comparative Analysis of 4 ImpressionTechniquesforImplantsLeonardoMoreiraCabral, MS,* and Carlos Gramani Guedes,DDS†IMPLANT DENTISTRY / VOLUME 16,NUMBER22007.

Ad

LVI #3

INDUSTRY CLINICAL