Meinberg Radio Clocks GmbH & Co. KG Lange Wand 9 31812 Bad Pyrmont, Germany Phone: +49 (0) 52 81 / 93 09 - 0 Fax: +49 (0) 52 81 / 93 09 - 30 Email: [email protected] Web: www.meinberg.de www.meinbergglobal.com LANTIME M1000 Intelligent Modular Synchronizaon The Ultra-Versale Plaorm for Your Time and Frequency Synchronizaon Applicaons

Upload: others

Post on 16-Apr-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: IMS M1000 - Modular Intelligent Synchronization · 2017-11-09 · All IMS Modules will report their status to the M1000 CPU and are easily field-replaceable. The management CPU can

Meinberg Radio Clocks GmbH & Co. KG

Lange Wand 931812 Bad Pyrmont, Germany

Phone: +49 (0) 52 81 / 93 09 - 0Fax: +49 (0) 52 81 / 93 09 - 30Email: [email protected]: www.meinberg.de www.meinbergglobal.com

LANTIME M1000 IntelligentModularSynchronization

TheUltra-VersatilePlatformforYourTime andFrequencySynchronizationApplications

Page 2: IMS M1000 - Modular Intelligent Synchronization · 2017-11-09 · All IMS Modules will report their status to the M1000 CPU and are easily field-replaceable. The management CPU can

AllIMSModuleswillreporttheirstatustotheM1000CPUandareeasilyfield-replaceable.ThemanagementCPUcanautomaticallyapplytheconfigurationofareplacedcardtoanewlyinsertedreplacementmodule.NeworremovedCLKandI/Omoduleswillberecognizedautomatically.

PWR –PowerSupplyOptions

IMS-PWR AD10: 100-240VAC/DC,50WIMS-PWR DC20: 20-72VDC,50W

• PowersupplymodulesindicateoperationalstatustoCPU.• Redundantconfigurationpossible.• Allpowersuppliesareoperatinginloadsharingmode.

CLK –Clockandcentraltimingmodules

IMS-GPS: GPSC/A-codereceiver(12channels) Antenna/ConverterSystem(IF35.4MHz) Max.Cablelengths:300m(RG58),700m(RG213)

IMS-GLN: CombinedGPS/GLONASSreceiver(32channels) Antenna:GPS/GLONASSL1 Max.Cablelength:100m(H155lowloss) AccuracyofpulseoutputsforIMS-GPSandIMS-GLN: <±100nstoUTC(TCXO,OCXOLQ) <±50nstoUTC(OCXO-SQ,-MQ,-HQ,-DHQ)

IMS-PZF: DCF77CorrelationReceiver Accuracyofpulseoutputs: <±50µstoUTC

Redundantclockconfigurationpossible(requiresanadditional integratedRSCswitchunit)

SCU –SignalChangeoverUnit(internal)

IMS-RSC: Redundant Switching of Sync signals coming from the IMS-CLKmodules.Highavailabilityofbasictimingsignals usedforallI/Omodules(1-PPS,10MHz,TOD). Seamlessswitchingof2048kHzsignalsfortelecomapplications.

IMS-SPT: SignalPathThrough(passivecardusedinnon-redundantsystems forwardingallsignalsfromtheclock).

CPU – NTP and Management Module

IMS-C051F: 500MHz,1x10/100BASE-TFastEthernetPort NTPServer: 10.000NTPreq/s Protocols: SNMP,SSH,Telnet,DHCP,IPv4,IPv6, 802.1q,RADIUS,TACACS+ ManagementuserinterfaceviawebinterfaceorCLI

MRI –MultipleReferenceInput

IMS-MRI: Basicreferenceinputsignals(BNC) - 1PPS -10MHz -IRIG-AM(B,AFNOR,IEEE1344/C37.118) -IRIG-DCLS(B,AFNOR,IEEE1344/C37.118)

ESI –ExtendedSynchronizationInterface

IMS-ESI: Extendedreferenceinputsignals -1PPS,BNC -var.frequencies(1kHz-10MHz)unframed,BNC -var.frequencies(1kHz-10MHz)unframed,RJ45 -BITSE1/T1framed,RJ45

ESI

2MHz,2MBit/sReferencevariablefrequencyInput

LNE

NetworkExpansionCard

TSUPTP / SyncE /

HardwareNTPInterface

AC/DCPowerSupplies

PWR CLKClockModule

GPS,GLONASS,PZF

CPU

Management & NTP Module

MRIReferenceInput

IRIG,1PPS,10MHz

Modules

Page 3: IMS M1000 - Modular Intelligent Synchronization · 2017-11-09 · All IMS Modules will report their status to the M1000 CPU and are easily field-replaceable. The management CPU can

LNE –LANNetworkExpansion

IMS-LNE: AdditionalnetworkportsforNTPandmanagement LNE-GbE: 4x10/100/1000BASE-TGigabitRJ45Ports

TSU –PTP/SyncE/HardwareNTPInterface

IMS-TSU-GbE:GigabitEthernet(RJ45/SFPComboPort) 10nstimestampresolution 1-Step/2-stepclock IEEE1588v2multiprofilesupport: - Default1588v2profile - ITU-TG.8265andG.8275Telecomprofiles - IEEEC.37.238-2011PowerProfile - SMPTEST2059-2BroadcastProfile Layer2/Layer3/IPv4/IPv6 E2E/P2P SynchronousEthernetIn/Out (ITU-TG.8261,G.8262,G.8264ESMC)

CarrierGradeNTP(10nstimestampresolution)

REL – Relay

Errorrelaycontactmoduleforerrorindicationofclockfaults.

IMS-REL:3xDFKConnectors(3-pinCO/NO/NC)forerrorindication ofCLK-1,CLK-2andRSC(redundantsystem)or 1xDFKConnector(3-pinCO/NO/NC)forerrorindication ofCLK-1

SCG –StudioClockGenerator

WordClockfrequenciesforprofessionalAudioEquipment

IMS-SCG:• programmblewordclockrates:24Hz–24,576MHz• defaultrates:44,1kHz,48kHz,88,2kHz,96kHz• 4xBNC(2.5VTTLinto50Ω)

VSG – Video-Sync Generator

TheVSG180isavideosignalreferenceforstudioequipment.Theboardis synchronizedbyanexternal10MHzsignal.Itgeneratesconfigurablevideosignalsindifferentformatstosynchronizestudioequipment:

• Bi-LevelSync(blackburst)• Tri-LevelSync

LNO –LowNoiseOption

IMS-LNO: 10MHzsinewaveoutputs(lowphasenoise). IntegratedPLLandlowphasenoiseoscillator(OCXO-MQ/HQ).

LIU – Line Interface Unit

IMS-LIU: E1/T1-generatoravailablewith4or8outputs.

Clock Outputs:2.048MHz(E1-mode)or1.544MHz(T1-mode),G.703,75Ohm,unbalancedor2.048MHz(E1-mode)or1.544MHz(T1-mode),G.703,120Ohm,balanced.

BITS - framed outputs with SSM/BOC support:2.048Mbps(E1-mode)or1.544Mbps(T1-mode),75Ohm,unbalancedor2.048Mbps(E1-mode)or1.544Mbps(T1-mode),120Ohm,balanced.

BPE –BasicPortExpansion

Back-Endusesunmodifiedstandardsignalsprovidedbybackplane.

Front-End BackEnd

IMS-BPEavailablesignals:• 1PPS,10MHzsquare-wave• 2.048MHzsquare-wave• IRIGDCLS+AM(B,AFNOR,IEEE1344/C37.118)• ProgrammablePulsesprovidedbyclockmodule

CPE –ConfigurablePortExpansion

Thismoduleconsistsofahalf-sizestandardcontrollercard(Back-End)andadockableportexpandercard(Front-End),allowingalargevarietyofavailableandprogrammableoutputsignalsandphysicalconnectors,includingvariouselectricalandopticalinterfaces.

IMS-CPEavailableSignals:• 1PPS,10MHz• TimeCodes:IRIGA/B/E/G/AFNOR/IEEE1344/C37.118/NASA36/XR3

AMandDCLS• FrequencySynthesizer(sine-wave+TTL)• ProgrammablePulses:1PPS,1PPM,1PPH,Timer,SingleShot,• CyclicPulses,DCF77Mark,SyncStatus• Serial Timestrings (RS232 or RS422 / 485)

ACM –ActiveCoolingModule

The Active Cooling Module allows the operative use of the M1000 in hightemperatureenvironments.Ahot-plugreplacement,withouttheneedtopowerdownthesystem,ispossibleatanytime.

BPE

Basic PortExpansion

LIU

E1/T1Generator

Page 4: IMS M1000 - Modular Intelligent Synchronization · 2017-11-09 · All IMS Modules will report their status to the M1000 CPU and are easily field-replaceable. The management CPU can

08/2015 - www.meinbergglobal.com

KEYFEATURES

• IMS-IntelligentModularSynchronizationplatform

• Hotswappable,field-replaceablemodules

• Endlesscombinationsofmodules

• Optimizedspaceusage

• Redundantpowerandreferencesources

• Web based management for all modules

• Upto16additionalLANports

• Upto4PTP(IEEE1588-2008)modules

• VarioustypesofI/Omodules

INPUTSIGNALOPTIONSGNSS: GPS,GLONASSRadioSignal: DCF77-PZFcorrelationreceiverTimeCodes: IRIGAM,IRIGDCLSSerialString: RS232TOD+PPSPulses: 1PPSFrequencies: variablefrequencies(1kHz-10MHz)BITS/Clock: E1|T1(framed)/2.048|1.544MHz(unframed)Network: NTP,IEEE1588v2,SynchronousEthernet

All available input signals can be configured to be used within the Meinberg MRS (Multi-Reference Sources) concept. The inputs are inte-grated intotheMeinberg IRSA(IntelligentReferenceSelectionAlgorithm)technologywhichallowsuser-definedprioritizationofinputsandautomaticreferencefail-overcontrol.

PWRTwoPWRslotsareavailableforhighpowerrequirementsandoptionalredundantconfigurations.DifferentmodelsareavailablesupportingwiderangeACand/orvariousDCvoltagerange.

CLKReferenceclockmoduleslotwhichholdseitheraGPS,GLONASSorPZFreceiverincluding the main oscillator. The clock module provides standard backplanesignalslike1PPS,10MHzandaserialtimestring.UptotwoCLKslotscanoperateperbackplane.

Usable Modules: IMS-GPS: GPSReceiverIMS-GLN:GPS/GLONASSReceiverIMS-PZF: DCF77CorrelationReceiver

SCUSwitchModule (internal), requiredwhen using a redundant receiver solution.Automaticorremotecontrolledchangeoverofsignalsources,seamlesschange-overof2.048MHzreferencesignalsforredundanttelecomapplications.

CPUHoldsaCPUmodulewhichoperatesasthemainchassiscontrollerandprovideswebinterfaceandothermanagementservicesaswellasNTP.TheIMSplatformsupportsoneCPUslotperbackplane.

MRI Usable Modules:IMS-MRI: Standardreferenceinputsignals(1PPS,10MHz,IRIG-AM,IRIG-DCLS)IMS-ESI: Extendedreferenceinputsignals(1PPS,var.frequencies,E1/T1)IMS-TSU: IEEE1588v2Input/Output,SynchronousEthernetInput/Output, NTP(Output)

SlotMRI1:InputsignalsaredirectlyconnectedtoCLK1SlotMRI2:InputsignalsaredirectlyconnectedtoCLK2(redundant) Outputsignalsareavailablefrombothclocks(switched)

All ESI and IO modules can operate in MRI slots.

ESI (ExtendedSynchronizationInterface)Usable Modules:IMS-ESI: Extendedreferenceinputsignals(1PPS,var.frequencies,E1/T1)IMS-TSU: IEEE1588v2Input/Output,SynchronousEthernet(Outputonly), NTP(Output).

SlotESI1: InputsignalsaredirectlyconnectedtoCLK1SlotESI2: InputsignalsaredirectlyconnectedtoCLK2(redundant) Outputsignalsareavailablefrombothclocks(switched)

All IO modules can operate in ESI slots.

IOUsable Modules:IMS-TSU: PTP/SyncE/HardwareNTPInterfaceIMS-BPE: BasicPortExpansionIMS-CPE: ConfigurablePortExpansionIMS-LIU: Line Interface Unit (E1/T1 Telecom Signals)IMS-LNO: 1MHzsineLowNoiseOptionIMS-LNE: LANnetworkexpansionIMS-SCG: StudioClockGenerator(Audio)IMS-VSG: Video Sync. GeneratorIMS-REL: Relaycontactmodule(ErrorOut)IMS-FDM: Frequencydeviationmonitorforpowerlinenetworks

ACMI/OCPU

I/OCLK1

ESI-CLK1orI/OESI-,MRI-CLK1orI/O

PWR-1PWR-2

IMS-SlotTypes

ACMI/OCPU

CLK2CLK1

ESI-,MRI-CLK2orI/OESI-,MRI-CLK1orI/O

PWR-1PWR-2

Redundant Receiver-Slot Assignment with internal RSC Switch Logic

Single Receiver-Slot Assignment