DESCRIPTION
To measure the exact light intensity of traffic lights from road level Imtech developed in association with TNO, the biggest independent research organization in the Netherlands, the traffic light intensity meter (TIM®).TRANSCRIPT
T I M ®
T R A F F I C L I G H T I N T E N S I T Y M E T E R
Traffic light maintenance The CROW-publication 246 'Traffic light maintenance' offers
guidance to road authority in drawing up a maintenance plan and
sets legal regulations, which have to be taken in account. The plan
describes three types of maintenance: inspection, preventive and
corrective maintenance.
Inspection During maintenance inspection the installation is investigated with
the use of check- and conformity lists. The road authority has to
keep the right inspection frequency to guaranty the quality of the
traffic installation, but at the same time has to avoid unnecessary
costs. A well maintained installation reduces the amount of failures
and the risk of out of order and also increases the life span of the
installation and therefore increasing safety for road users.
Measuring of light intensity The intensity meter enables to monitor and register light intensity in
practical situations. By regular monitoring the road authority is able
to service the traffic lights in an early stage. Through early servicing
traffic lights can keep meeting legal requirements. The use of an
intensity meter can be an obligatory component of maintenance
contracts.
To secure the safety on the road, traffic lights need to be
clearly visible for road users. The light intensity has to be
sufficient under every (weather) circumstance, which is set in
legal standards. To measure the exact light intensity of traffic
lights from road level Imtech developed in association with
TNO, the biggest independent research organization in the
Netherlands, the traffic light intensity meter (TIM®).
Traffic light intensity In the course of time, the luminous intensity of traffic lights slowly
decreases. Possible reasons are pollution of lenses or reflectors,
aging of the light source or individual LED failure. TIM® enables the
road authority to carry out timely services, in such a way that traffic
lights keep satisfying the statutory rules for optimal traffic safety.
Imtech Infra B.V.
Hardwareweg 11, 3821 BL Amersfoort
Postbus 725, 3800 AS Amersfoort
T +31(0) 33 450 22 11
F +31(0) 33 455 98 12
I www.imtech.nl/infra
Specifications TIM
� The measurement is color independent
� Measurement conform the NEN-EN 12368
� The measurement can directly be read from the PDA
display
� Fully calibrated by TNO
� Available for 200mm and 300mm traffic lights
� Suitable for conventional and LED lights
� Custom made adapters available for all types and brands
of traffic lights
NEN-EN 12368
The Dutch normalization-institute has published the norm NEN-EN
12368 in January 2000. This norm sets technical demands for traffic
installations in the Netherlands. The NEN-EN 12368 norm states
that the intensity of traffic lights with replaced bulbs and cleaned
reflector and lenses should be at least 80% of 400cd. Until now, this
requirement could not be measured under environmental
circumstances, the TIM provides this possibility.