35
Manufacturers of I In-Floor Access for Grocery, Retail, Manufacturing, Industrial and Institutional Available for use with our composite liners or your on-site constructed pit. We can configure a unit to any size and cover requirements. Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures 700 Henry Circle, Sinking Spring, PA 19608 Phone: 610-678-8200 Fax: 610-678-8201 E-mail: craiggmfg @craigg.com www.CRAIGG.com Manufactured In-Floor access enclosures and pit systems for providing access to under-floor: • Mechanicals • Water piping and valves • Drainage hubs and piping • Electrical wiring and controls • Refrigeration piping and controls Time Saving Installations, Convenience, Standardization For Gaining Access To Under Floor Mechanicals ! Patent 5.412.911 In-Floor Access Enclosures 12

Upload: others

Post on 13-Sep-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

Manufacturers of

IIn-Floor Access for Grocery, Retail, Manufacturing, Industrial and Institutional

Available for use with our composite liners or your on-site constructed pit.

We can configure a unit to any size and cover requirements.

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures 700 Henry Circle, Sinking Spring, PA 19608

Phone: 610-678-8200 Fax: 610-678-8201 E-mail: craiggmfg @craigg.com www.CRAIGG.com

Manufactured In-Floor access enclosures and pit systems for providing access to under-floor: • Mechanicals • Water piping and valves • Drainage hubs and piping • Electrical wiring and controls • Refrigeration piping and controls

Time Saving Installations, Convenience, Standardization For Gaining Access To Under Floor Mechanicals !

Patent 5.412.911

In-Floor Access Enclosures

12

Page 2: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

Borderless Covers

Installation Detail

Two Piece Cover

Section 1-1

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures 700 Henry Circle, Sinking Spring, PA 19608

Phone: 610-678-8200 Fax: 610-678-8201 E-mail: [email protected] www.CRAIGG.com

12

SECTION 1

SECTION 2

SECTION 3

SECTION 4

SECTION 5

SECTION 6

SECTION 7

SECTION 8

The ADJUSTOR

Construction Detail

The POUROVER Construction Detail

ADJUSTOR FRAME

Installation Detail

RIGIDCAST Construction Detail

Installation Detail

RIGIDCAST TRU SCREED Construction Detail

POUROVER FRAME Construction Detail

Installation Detail

Bordered Covers

Flush Covers

Partial Covers Cover Supports

Two Part Frame Assembly Combination Adjustor and Pourover Frame & Liner

Angled Adjustor and Pourover Frame & Liner Double End Adjustor with Pourover Center Frame & Liner

Combination Adjustor ,Pourover and Open Area Frame & Liner Flush Mounting Unit Frame & Liner

Fixed Cover with Frame & Liner

Installation Detail

SECTION 9

Construction Detail

Page 3: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

UPPER: Extruded Aluminum 6105-T5 B221 LOWER: 7 Gauge (0.1793”) thick, Low Carbon Steel A36 GASKET: Shore Type A Cork-Rubber w/ Acrylic PSA D2240 STUD: 7/16-14 TPI x 4” Lg., Low Carbon Steel w/ Yellow Zinc Grade 2 A307

Section 1-2

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures

Phone: 610-678-8200 Fax: 610-678-8201 E-mail: [email protected] www.CRAIGG.com

12

This data is composite of manufacturers data of raw goods and current industry ratings of such goods. Craigg Mfg. assumes no responsibility for any possible errors in these ratings and believes this data to be correct at this printing.

ASTM

BORDER FRAME: Extruded Aluminum 6105-T5 B 221 PLATE: 0.25” or 0.375” thick, Aluminum Plate 6061, Temper T651, Mill Finish B209 ALUMINUM TREAD PLATE: 0.25” or 0.375” thick, 6061, Temper T651 B632 STEEL PLATE: 0.25” Thick, Low Carbon Steel, Hot Rolled A36 POL/POF METAL DECK: 22 Gauge G60 Galvanized Raised Rib A653

COMPOSITE: Fiber Reinforced Polyester Resin D638 Molded Vertical Support Gussets Color: Gray Weight Density: 1.5 Pounds Per Square Foot (Average) Tensile Strength: PSI 10,000 @ 45% Styrene

Page 4: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

��Adjustability Allowing Frame

& Cover To Compensate For Uneven Floor and Different Floor Covering Material

��Vast Selection Of Unit Sizes,

Cover Sizes And Cover Styles

��Attractively Finished Aluminum Frame Mounted Within A Steel Structural Frame

��Highly Durable Composite Liner That Will Provide A Lifetime Of

Service ��Steel Securing Rods That Holds

The Unit In Alignment During Installation

T he ADJUSTOR is a unitized in-floor pit enclosure that allows access to refrigeration, electrical, plumbing, pumps and many other

mechanicals. It’s unitized construction provides for a One Step installation that’s quick and easy, which directly relates to a labor savings. Installers like its workability and ease of handling. If penetrations are required they will not compromise the liner strength.

No special site preparation is needed, just place the unit on a

solid substrate base that’s free of piercing objects. Securing rods stabilize the unit until backfilled and the concrete floor is poured.

Positive alignment of the liner is not necessary when setting. The aluminum frame can be adjusted to be fine tuned for uneven floors and flooring materials by raising and leveling to match the surrounding conditions. Covers can be selected from our numerous variety of sizes, materials, styles and offsets available. Provided in steel or lightweight aluminum and then finished to match any type floor covering .

FRAME AND COMPOSITE LINER ASSEMBLY

INSTALLATION BEFORE POURING FLOOR

Section 2-1

Fig. 2.2

Fig. 2.1

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures

Phone: 610-678-8200 Fax: 610-678-8201 E-mail: [email protected] www.CRAIGG.com

F e a t u r e s That Make Us Your First Choice:

INSTALLATION BEFORE POURING FLOOR

Fig. 2.1

12

Patent 5.412.911

Page 5: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

INTERIOR WIDTH OR LENGTH OF COMPOSITE LINER "A" OR "B"

OVERALL DEPTH OF COMPOSITE LINER - "C"

USEABLE DEPTH OF COMPOSITE LINER - "D"

ACTUAL OPENING OF FRAMEW ORK - "E" - IS 3-1/2" LESS THAN ACTUAL SIZE OF W IDTH OR LENGTH

96"90"84"78"72"66"60"54"48"42"36"30"24"18"12"NOMINAL SIZE

96-1/16"90-1/8"84-3/16"78-1/4"72-5/16"66-3/8"60-7/16"54-1/2"48-9/16"42-5/8"36-11/16"30-3/4"24-7/8"18-3/4"12-13/16"ACTUAL SIZE

36"30"24"18"* 15"13"

33-3/4"27-3/4"21-3/4"15-3/4"* 12-3/4"10-3/4"

Section 2-2

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures

Phone: 610-678-8200 Fax: 610-678-8201 E-mail: [email protected] www.CRAIGG.com 12

Fig. 2.3

DIMENSIONAL INFORMATION

Liners are offered in an almost unlimited selection of sizes from 12” x 12” x 15” deep to 60” x 60” x 36” deep. Oth-er sizes are available upon special request. Liners are available in six inch increments in any direction.

� 12” x 12” IS ONLY AVAILABLE IN 15” DEPTH.

OR LENGTH

THE ALUMINUM FRAME HAS AN ADJUSTMENT RANGE OF 2” TO ALLOW FOR SETTING VARIABLES, UNEVENLY POURED FLOORS AND FLOOR COVERING MATERIALS.

DIMENSIONS MAY VARY DUE TO MOLD CONFIGURATION.

34 A

DC

B

POURED FLOOR LINE

E

2POURED FLOOR LINE

ADJUSTABLE TO...

MAXIMUM SETTING MINIMUM SETTING

ALUMINUM FRAME & COVER

COMPOSITE LINER

FRAME AND COMPOSITE LINER ASSEMBLY

Page 6: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

Section 2-3

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures

Phone: 610-678-8200 Fax: 610-678-8201 E-mail: [email protected] www.CRAIGG.com 12

POURED FLOOR

FINE AGGREGATE OR SAND

FRAME ANCHORMUST BE CAST IN CONCRETE

COMPOSITE LINER

LINER SECURING RODS

EARTH

WITH THE UPPER FRAME BEINGADJUSTABLE UPWARD AS MUCH AS 2 INCHES,LESS ACCURACY IS REQUIRED WHEN SETTING

THE LINER.

FRAME

POURED FLOOR LINEADJUST FOR FLOORING SELECT COVER IN SECTION 8MATERIAL AFTER POUR

THE LINER TOP FLANGE CAN RANGE FROM 3/4" TO 2" BELOWTHE FINISH POUR LINE.

I nstallation can be accomplished in several ways. The preferred way takes advantage of ADL’s adjusting feature.

Place and level the unit with the top edge of the f inished aluminum frame even with

the proposed f inal poured floor. This al lows for concrete f inishers to produce a clean and level f loor around the unit ’s frame. After the concrete cures, evenly turn the adjustors on the underside of the frame to raise it out of the concrete to a level that matches your choice of f looring material .

Fig. 2.4

An alternat ive method is to level the

frame’s top edge to i ts f inal elevat ion, including the f looring material . Pour and f inish the concrete to a level al lowing for the f looring materia l .

Page 7: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

��Steel Structural Frame with Supporting Concrete Anchors

��Highly Durable Composite Liner That Will Provide A Lifetime Of

Service ��Steel Securing Rods That Holds

The Unit In Alignment During Installation

FRAME AND COMPOSITE LINER ASSEMBLY

Section 3-1

Fig. 3.2

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures

Phone: 610-678-8200 Fax: 610-6780-8201 E-mail: [email protected] www.CRAIGG.com

12

��Wood Pour Stop Included for

Concrete Finishing Convenience ��Vast Selection Of Unit Sizes ��Optional Ribbed Steel to

Support Poured Cover or a Non-Load Bearing Removable Closeoff

FRAME AND COMPOSITE LINER ASSEMBLY

Fig. 3.2

T he Pourover is a unitized in-floor pit enclosure that allows access to refrigeration, electrical, plumbing,

pump and many other mechanicals. Its unitized construction provides for a One Step installation that’s fast and easy, reducing your labor cost. Installers like its workability and ease of handling. Cutting pen-etrations will not compromise the liner strength.

No special site preparation is needed, just place the unit

on a solid substrate base that’s free of piercing objects. Securing rods stabilize the unit until backfilled and the concrete floor is poured.

The provided wood pourstop creates a concrete stop to prevent wet concrete from entering the unit.

The provided blocking is designed to allow for a 4” poured cap if it is to be used. The pourstop has been designed with a 10 degree taper, this helps avoid settlement of the cap at a future time.

Model POL combines the frame and liner assembly that can, with the use of a ribbed steel cover, create a

completely hidden unit. After all necessary work has been performed in the unit, a concrete cap is poured over the opening forming a non-accessible enclosure.

Unit can also be left accessible through a non-load bearing galvanized steel closeoff. Covers available are 22 gauge galvanized ribbed decking , (concrete pour), and 20 gauge galvanized

steel closeoff.

F e a t u r e s That Make Us Your First Choice:

Page 8: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

INTERIOR WIDTH OR LENGTH OF COMPOSITE LINER "A" OR "B"

ACTUAL OPENING OF FRAMEWORK - "E" - IS 3-1/2" LESS THAN ACTUAL SIZE OF WIDTH OR LENGTH

90"84"78"72"66"60"54"48"42"36"30"24"18"12"NOMINAL SIZE

90-1/8"84-3/16"78-1/4"72-5/16"66-3/8"60-7/16"54-1/2"48-9/16"42-5/8"36-11/16"30-3/4"24-7/8"18-3/4"12-13/16"ACTUAL SIZE

OVERALL DEPTH OF COMPOSITE LINER - "C"

36"30"24"18"* 15"13"

USEABLE DEPTH OF COMPOSITE LINER - "D"

33-3/4"27-3/4"21-3/4"15-3/4"* 12-3/4"10-3/4"

Section 3-2

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures

Phone: 610-678-8200 Fax: 610-678-8201 E-mail: [email protected] www.CRAIGG.com 12

Fig. 3.3

DIMENSIONAL INFORMATION Liners are offered in an almost unlimited selection of sizes from 12” x 12” x 15” deep to 60” x 60” x 36” deep. Oth-

er sizes are available upon special request. Liners are available in six inch increments in any direction.

� 12” x 12” IS ONLY AVAILABLE IN 15” DEPTH.

DIMENSIONS MAY VARY DUE TO MOLD CONFIGURATION.

B

DC

APOURED FLOOR LINE

COMPOSITE LINER

Useable area.All access must bewithin this area

STEEL DECKING

FOR POURED COVER

WOOD

POUR STOP

OPTIONAL 20 GA. GALVANIZE

FOR REMOVABLE CLOSE-OFF

1-1/2"

TO BE REMOVEDAFTER POUR

E

Page 9: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

POURED FLOOR

FINE AGGREGATE OR SAND

FRAME ANCHORMUST BE CAST IN CONCRETE

COMPOSITE LINER

LINER SECURING RODS

EARTH

WOOD FORMSET TO FINISH FLOOR HEIGHT

Section 3-3

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures

Phone: 610-678-8200 Fax: 610-678-8201 E-mail: [email protected] www.CRAIGG.com 12

POURED CONCRETE COVER

STEEL DECKING

POURED FLOOR

FINE AGGREGATE OR SAND

FRAME ANCHORMUST BE CAST IN CONCRETE

COMPOSITE LINER

LINER SECURING RODS

EARTH

Fig. 3.3

Fig. 3.4

Page 10: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

The Adjustor Frame and cover assembly is designed

to be mounted on top of a field designed and built pit. It has all the adjustability features as our Model ADL that’s would mount in our composite liner. The structural steel frame with its anchors, rests on top of the field constructed pit walls and will cast directly into the poured floor. It is the ideal frame assembly to be utilized with field de-signed and built enclosures allowing access to refrigeration, electrical, plumbing, pump and many other mechanicals.

Positive alignment of the frame is not necessary when setting. The aluminum frame can be fine tuned later

for levelness and floor cover matching by raising and leveling the exposed frame to match surrounding conditions.

Covers can be selected from the numerous variety of sizes, materials, styles and offsets. Available in

steel or lightweight aluminum and then finished to match any type floor covering .

FRAME ASSEMBLY

Section 4-1

Fig. 4.1

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures

Phone: 610-678-8200 Fax: 610-678-8201 E-mail: [email protected] www.CRAIGG.com

12

��Attractively Finished Aluminum

Frame Mounted Within A Steel Structural Frame

��Structural Steel Base Frame

with Anchors for Casting Directly into Floor

��Full Perimeter Sealing Gasket

��Vast Selection of Cover

Designs, Sizes, Material

��Adjustability Allowing Frame & Cover To Compensate For Uneven Floor and Different Floor Covering Material

ADJUSTABLE ASSEMBLY TO BE USED WITH ON-SITE CONSTRUCTED PITS

F e a t u r e s That Make Us Your First Choice:

Page 11: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

278

4

POURED FLOOR LINE FOR 1/8" VINYL TILE

POURED FLOOR LINE FOR 1/2" QUARRY TILE

B

A

D

C

SELECT COVERS FROM SECTION 8

SELECT COVERS FROM SECTION 8

FORMING SUPPORT TAB

FORMING SUPPORT TAB

ADJUSTOR NUT

JAM NUT

ADJUSTOR NUT

JAM NUT

INSIDE OF PIT WALL OR WOOD FORMING MATERIAL

THIS IS THE MAXIMUM PLACEMENT OF THE BASE FRAME BELOW FINISH FLOOR IS 1/2" QUARRY TILE IS TO BE USED

THIS IS THE MINIMUM PLACEMENT OF THE BASE FRAME BELOW FINISHED FLOOR IF 1/8" VINYL TILE IS TO BE USED

FRAME SHOWN AT MINIMUMPLACEMENT AND ADJUSTMENT

FRAME SHOWN AT MAXIMUMPLACEMENT AND ADJUSTMENT

E

Section 4-2

Fig. 4.2

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures

Phone: 610-678-8200 Fax: 610-678-8201 E-mail: [email protected] www.CRAIGG.com 12

ADJUSTABLE ASSEMBLY TO BE USED WITH ON-SITE CONSTRUCTED PITS

W IDTH OR LENGTH OF ALUMINUM FRAME "A" OR "B"

WIDTH OR LENGTH OF INSIDE WALL OF FIELD FORMED PIT - "C" OR "D"

ACT UAL OPENING OF FRAMEW ORK - "E" - IS 2-1/2" LESS T HAN ACT UAL SIZE OF WIDT H OR LENGT H

96"90"84"78"72"66"60"54"48"42"36"30"24"18"12"NOMINAL SIZE

95"89-1/16"83-1/8"77-3/16"71-1/4"65-5/16"59-3/8"53-7/16"47-1/2"41-9/16"35-5/8"29-11/16"23-3/4"17-13/16"11-7/8"ACTUAL SIZE

93-1/8"87-3/16"81-1/4"75-5/16"69-3/8"63-7/16"57-1/2"51-9/16"47-5/8"39-11/16"33-3/4"27-13/16"21-7/8"15-15/16"10"

Manufactured sizes shown. Custom sizes also available.

Fig. 4.3

DIMENSIONAL INFORMATION

AT MINIMUM ADJUSTMENT

AT MAXIMUM ADJUSTMENT

Page 12: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

Section 4-3

Fig. 4.4

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures

Phone: 610-678-8200 Fax: 610-678-8201 E-mail: [email protected] www.CRAIGG.com 12

ADJUSTABLE ASSEMBLY TO BE USED WITH ON-SITE CONSTRUCTED PITS

Fig. 4.5

EARTH

Remove inner form after pourOuter form can be eliminated

FINE AGGREGATE OR SAND

BEND DOWN TO SECURE FRAME

FRAME ASSEMBLY(SET TOP EDGE FLUSH WITH THE TOP OF THE POURED FLOOR LINE) ADJUST FRAME TO PROPER HEIGHT AFTER FLOOR IS POUREDTO ACCOMMODATE THE FLOORING MATERIAL

LEAVE PROTECTIVE FILM ON THE ALUMINUM FRAME FOR PROTECTION

PIT DEPTH DESIGNBY OTHERS

MONOLITHIC POUR

FORMING SUPPORT TAB

FRAME ANCHORMUST BE CAST IN CONCRETE

SPACING BLOCK

PLYWOOD FORMS

PRE-POUREDCONCRETE PAD

Concrete Block Pit

Formed Monolithic

CONCRETE POUR

FINE AGGREGATE OR SAND

FRAME ANCHORMUST BE CAST IN CONCRETE

CONCRETE BLOCK

PRE-POUREDCONCRETE PAD

EARTH

FRAME ASSEMBLY(SET TOP EDGE FLUSH WITH THE TOP OF THE POURED FLOORLINE) ADJUST FRAME TO PROPER HEIGHT AFTER FLOOR IS POURED TOACCOMODATE FLOORING MATERIAL

FORMING SUPPORT TABPIT DEPTH DESIGN

BY OTHERS

LEAVE PROTECTIVE FILM ON THE ALUMINUM FRAME FOR PROTECTION

Page 13: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

The RigidCast Frame and cover is a straight forward

designed frame that casts directly into a poured floor or can be utilized with field designed and built enclosures. It is the ideal unit to allow access to refrigeration, electrical, plumbing, pump and many other mechanicals Choose this unit when a straight forward approach is needed.

Its unitized construction provides for a One Step

installation that’s fast and easy. Securing anchors provides support to the frame for a more secure cover loading. The aluminum finish will prove to be attractive and maintenance free for years ahead.

Covers can be selected from the numerous variety of sizes, materials, styles and offsets. Available in steel or lightweight aluminum and then finished to match any type floor covering .

FRAME ASSEMBLY

Section 5-1

Fig. 5.1

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures

Phone: 610-678-8200 Fax: 610-678-8201 E-mail: [email protected] www.CRAIGG.com

F e a t u r e s That Make Us Your First Choice:

12

��Attractively Finished Aluminum

frame with in-fitting cover choic-es

��Securing Anchors that secures

frame firmly in the concrete floor pour

��Full Perimeter Sealing Gasket

��Vast Selection of Cover

Designs, Sizes, Material Sub-strates

��Fastener Free Cover rest in-to the deep setting frame channel eliminating the need for mechanical fasteners

RIGID FRAME ASSEMBLY TO BE USED WITH ON-SITE CONSTRUCTED PITS

CASTS DIRECTLY INTO THE POURED CONCRETE FLOOR

Page 14: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

B

A

312

1516 D

C

SELECT COVERS FROM SECTION 8

ADJUST TO THE THICKNESSOF THE FLOORING MATERIAL

WHEN FORMING IN

E

Section 5-2

Fig. 5.2

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures

Phone: 610-678-8200 Fax: 610-678-8201 E-mail: [email protected] www.CRAIGG.com

12

RIGID FRAME ASSEMBLY TO BE USED WITH ON-SITE CONSTRUCTED PITS

CASTS DIRECTLY INTO THE POURED CONCRETE FLOOR

DIMENSIONAL INFORMATION

W IDTH OR LENGTH OF ALUMINUM FRAME "A" OR "B"

WIDTH OR LENGTH OF INSIDE WALL OF FIELD FORMED PIT - "C" OR "D"

ACT UAL OPENING OF FRAMEW ORK - "E" - IS 2-1/2" LESS T HAN ACT UAL SIZE OF WIDT H OR LENGT H

96"90"84"78"72"66"60"54"48"42"36"30"24"18"12"NOMINAL SIZE

95"89-1/16"83-1/8"77-3/16"71-1/4"65-5/16"59-3/8"53-7/16"47-1/2"41-9/16"35-5/8"29-11/16"23-3/4"17-13/16"11-7/8"ACTUAL SIZE

93-1/8"87-3/16"81-1/4"75-5/16"69-3/8"63-7/16"57-1/2"51-9/16"47-5/8"39-11/16"33-3/4"27-13/16"21-7/8"15-15/16"10"

Manufactured sizes shown. Custom sizes also available.

Page 15: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

Section 5-3

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures

Phone: 610-678-8200 Fax: 610-678-8201 E-mail: [email protected] www.CRAIGG.com

12

RIGID FRAME ASSEMBLY TO BE USED WITH ON-SITE CONSTRUCTED PITS

MONOLITHIC POUR

FINE AGGREGATE OR SAND

FRAME ANCHORMUST BE CAST IN CONCRETE

SPACING BLOCK

PLYWOOD FORMS

PRE-POUREDCONCRETE PAD

EARTH

Remove inner form after pourOuter form can be eliminated

PIT DEPTH DESIGNBY OTHERS

FRAME

ALLOW PROPER CLEARANCEFOR FLOORING MATERIAL

CONCRETE POUR

FINE AGGREGATE OR SAND

FRAME ANCHORMUST BE CAST IN CONCRETE

CONCRETE BLOCK

PLYWOOD FORMS

PRE-POUREDCONCRETE PAD

PIT DEPTH DESIGNBY OTHERS

FRAME

ALLOW PROPER CLEARANCEFOR FLOORING MATERIAL

EARTH

USE EITHERMETHOD

NAILER

Formed Monolithic

Concrete Block

Fig. 5.4

Fig. 5.3

Page 16: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

The RigidCast TruScreed Frame and cover is a

straight forward designed frame with the added feature of a finishing guide around its perimeter. The unit casts directly into a poured floor or can be utilized with field de-signed and built enclosures. It is the ideal unit allowing access to refrigeration, electrical, plumbing, pump and many other mechanicals. To help eliminate the problem of finishing floors evenly around floor frames we built the needed flooring material thickness into a finishing guide angle. When you order the unit with the required offset we provide a perfect edge for concrete finishing.

Covers can be selected from the numerous variety of sizes, materials, styles and offsets. Available in steel or lightweight aluminum and then finished to match any type floor covering .

Section 6-1

Fig. 6.1

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures

Phone: 610-678-8200 Fax: 610-678-8201 E-mail: [email protected] www.CRAIGG.com

F e a t u r e s That Make Us Your First Choice:

12

��Attractively Finished Aluminum

frame with in-fitting cover choic-es

��Securing Anchors that secures

frame firmly in the concrete floor ��Full Perimeter Sealing Gasket

��Vast Selection of Cover

Designs, Sizes, Material

��Attached Flange around the

perimeter provides a screed guide for a perfectly level finished edge.

RIGID FRAME ASSEMBLY TO BE USED WITH ON-SITE CONSTRUCTED PITS

CASTS DIRECTLY INTO THE CONCRETE POUR

Page 17: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

Section 6-2

Fig. 6.2

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures

Phone: 610-678-8200 Fax: 610-678-8201 E-mail: [email protected] www.CRAIGG.com

12

RIGID FRAME ASSEMBLY TO BE USED WITH ON-SITE CONSTRUCTED PITS

A

B

312

1516 D

C

SELECT COVERS FROM SECTION 8

E

POURED FLOOR LINEFINISH FLUSH WITH

METAL GUIDE

OFFSET IS MANUFACTUREDIN FOR ANY THICKNESSOF FLOORING MATERIAL

UP TO 1/2" THICK

DIMENSIONAL INFORMATION

W IDTH OR LENGTH OF ALUMINUM FRAME "A" OR "B"

WIDTH OR LENGTH OF INSIDE WALL OF FIELD FORMED PIT - "C" OR "D"

ACT UAL OPENING OF FRAMEW ORK - "E" - IS 2-1/2" LESS T HAN ACT UAL SIZE OF WIDT H OR LENGT H

96"90"84"78"72"66"60"54"48"42"36"30"24"18"12"NOMINAL SIZE

95"89-1/16"83-1/8"77-3/16"71-1/4"65-5/16"59-3/8"53-7/16"47-1/2"41-9/16"35-5/8"29-11/16"23-3/4"17-13/16"11-7/8"ACTUAL SIZE

93-1/8"87-3/16"81-1/4"75-5/16"69-3/8"63-7/16"57-1/2"51-9/16"47-5/8"39-11/16"33-3/4"27-13/16"21-7/8"15-15/16"10"

Manufactured sizes shown. Custom sizes also available.

CASTS DIRECTLY INTO THE POURED CONCRETE FLOOR

Page 18: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

Section 6-3

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures

Phone: 610-678-8200 Fax: 610-678-8201 E-mail: [email protected] www.CRAIGG.com

12

RIGID FRAME ASSEMBLY TO BE USED WITH ON-SITE CONSTRUCTED PITS

MONOLITHIC POUR

FINE AGGREGATE OR SAND

FRAME ANCHORMUST BE CAST IN CONCRETE

SPACING BLOCK

PLYWOOD FORMS

PRE-POUREDCONCRETE PAD

EARTH

Remove inner form after pourOuter form can be eliminated

PIT DEPTH DESIGNBY OTHERS

FRAME

BUILT IN CLEARANCEFOR FLOORING MATERIAL

ANGLE AT POURED FLOOR LINE

CONCRETE POUR

FINE AGGREGATE OR SAND

FRAME ANCHORMUST BE CAST IN CONCRETE

CONCRETE BLOCK

PLYWOOD FORMS

PRE-POUREDCONCRETE PAD

EARTH

USE EITHERMETHOD

NAILER

PIT DEPTH DESIGNBY OTHERS

FRAME

BUILT IN CLEARANCEFOR FLOORING MATERIAL

ANGLE AT POURED FLOOR LINE

Formed Monolithic

Concrete Block Fig. 6.3

Fig. 6.4

Page 19: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

The Pourover Frame assembly gives support to

floor openings and also creates support for a poured concrete cover or metal closeoff.

The flanged edge and mounted anchors allows it to embed firmly into the concrete floor for greater load bearing.

The provided wood pourstop creates a

concrete stop to prevent cement while pouring from entering the unit. The provided blocking is designed to allow for a 4” poured cap if it is to be used. The pourstop has been designed with a 10 degree taper, this helps avoid settlement of the cap at a future time.

Covers available are 22 gauge galvanized ribbed decking , (concrete pour), and 20 gauge galvanized steel

closeoff

Section 7-1

Fig. 7.1

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures

Phone: 610-678-8200 Fax: 610-678-8201 E-mail: [email protected] www.CRAIGG.com

F e a t u r e s That Make Us Your First Choice:

12

��Structural Steel frame for

supporting cover or poured cap

��Wood pourstop holds back

wet concrete and provides the needed offset

��Cover Selection of 20 gauge

ribbed decking or 20 gauge galvanized smooth

��Securing Anchors secures

frame firmly into concrete floor

POUROVER ASSEMBLY TO BE USED WITH ON-SITE CONSTRUCTED PITS

CASTS DIRECTLY INTO THE CONCRETE POUR

Page 20: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

A

POURED FLOOR LINE

B

STEEL DECKING

FOR POURED COVER

WOOD

POUR STOP

FOR REMOVABLE CLOSE-OFF

1-1/2"

TO BE REMOVEDAFTER POUR

C

334

FORMING SUPPORT TAB

D

Section 7-2

Fig. 7.2

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures

Phone: 610-678-8200 Fax: 610-678-8201 E-mail: [email protected] www.CRAIGG.com

12

POUROVER ASSEMBLY TO BE USED WITH ON-SITE CONSTRUCTED PITS

CASTS DIRECTLY INTO THE CONCRETE POUR

DIMENSIONAL INFORMATION

Manufactured sizes shown. Custom sizes also available.

INTERIOR W IDTH OR LENGTH OF INSIDE W ALL OF FIELD FORM ED PIT "A" OR "B"

96"90"84"78"72"66"60"54"48"42"36"30"24"18"12"NOMINAL SIZE

93-1/8"87-3/16"81-1/4"75-5/16"69-3/8"63-7/16"57-1/2"51-9/16"47-5/8"39-11/16"33-3/4"27-13/16"21-7/8"15-15/16"10"ACTUAL SIZE

INTERIOR W IDTH OR LENGTH OF FRAME OPENING - "C" OR "D"

92-9/16"86-5/8"80-11/16"75-3/4"68-13/16"62-7/8"56-15/16"51"45-1/16"39-1/8"33-3/16"27-1/4"21-5/16"15-3/8"9-7/16"

Page 21: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

WOOD FORM

MONOLITHIC POUR

FORMING SUPPORT TAB

FRAME ANCHORMUST BE CAST IN CONCRETE

SPACING BLOCK

PLYWOOD FORMS

PRE-POUREDCONCRETE PAD

SET TO FINISH FLOOR HEIGHT

EARTH

Remove inner form after pourOuter form can be eliminated

PIT DEPTH DESIGNBY OTHERS

FINE AGGREGATE OR SAND

BEND DOWN TO SECURE FRAME

Section 7-3

Fig. 7.3

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures

Phone: 610-678-8200 Fax: 610-678-8201 E-mail: [email protected] www.CRAIGG.com

12

POUROVER ASSEMBLY TO BE USED WITH ON-SITE CONSTRUCTED PITS

CONCRETE POUR

FINE AGGREGATE OR SAND

FRAME ANCHORMUST BE CAST IN CONCRETE

CONCRETE BLOCK

PRE-POUREDCONCRETE PAD

EARTH

FORMING SUPPORT TAB

PIT DEPTH DESIGNBY OTHERS

SET TO FINISH FLOOR HEIGHT

Formed Monolithic

Concrete Block Pit

Fig. 7.4

Page 22: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

FINE AGGREGATE OR SAND

STEEL DECKING

POURED CONCRETE COVER

CONCRETE POUR

FRAME ANCHORMUST BE CAST IN CONCRETE

Section 7-4

Fig. 7.5

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures

Phone: 610-678-8200 Fax: 610-678-8201 E-mail: [email protected] www.CRAIGG.com

12

POUROVER ASSEMBLY TO BE USED WITH ON-SITE CONSTRUCTED PITS

CONCRETE POUR

FRAME ANCHORMUST BE CAST IN CONCRETE

FINE AGGREGATE OR SAND

20 GA. GALVANIZED STEEL PLATE

STEEL CLOSE-OFF

Poured Cover Cap In-Place

Removable 20 Gauge Galvanized Closeoff (For non load bearing applications)

Fig. 7.6

Page 23: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

1/4" ALUMINUM COVERS

1/4" TILE

3/8" TILE

1/2" TILE

1/4" OFFSETEPOXY FINISHES

TERRA TILE

3/8" OFFSETCERAMIC TILEMARBLE TILE

1/2" OFFSETQUARRY TILE

3/8" ALUMINUM COVERS

ALUM. COVER

FRAME

1/8" TILE

1/4" TILE

1/2" TILE

3/8" TILE

1/8" OFFSETVINYL TILE

1/4" OFFSETEPOXY FINISHES

TERRA TILE

3/8" OFFSETCERAMIC TILEMARBLE TILE

1/2" OFFSETQUARRY TILE

1/4" STEEL COVERS

1/8" OFFSETVINYL TILE

STEEL COVER

FRAME

1/8" TILE

1/4" TILE

3/8" TILE

1/2" TILE

1/4" OFFSETEPOXY FINISHES

TERRA TILE

3/8" OFFSETCERAMIC TILEMARBLE TILE

1/2" OFFSETQUARRY TILE

1/8" OFFSETVINYL TILE

ALUM COVER

FRAME

1/8" TILE

Section 8-1

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures

Phone: 610-678-8200 Fax: 610-678-8201 E-mail: [email protected] www.CRAIGG.com

12

Bordered Covers provide protection for your flooring material edges. All of the flooring material becomes recessed into the protective frame. The cover is reversible, e.g. the 1/4” cover with an 1/8” offset is the reverse side of the 1/2” offset. Due to its deep setting design the cov-er requires no screws or fas-teners to secure it in place.

Page 24: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

Section 8-3

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures

Phone: 610-678-8200 Fax: 610-678-8201 E-mail: [email protected]

12

1/4" ALUMINUM COVER

3/8" ALUMINUM COVER

1/4" STEEL COVER

TREAD PLATE

FLUSH MILL FINISH

CONCEALED

FRAME

FRAME

FRAME

1/4" ALUMINUM COVER

3/8" ALUMINUM COVER

1/4" STEEL COVER

1/4" ALUMINUM COVER

3/8" ALUMINUM COVER

1/4" STEEL COVER

Flush Covers provides a natural metallic finish. Available in a Treadplate pattern or a brushed mill finish. Covers can add a contrast to the surrounding finish. With its deep setting design the cover requires no screws or fasteners to secure it in place.

Page 25: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

OPTIONAL CENTER SUPPORT

C

A

B

Section 8-4

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures

Phone: 610-678-8200 Fax: 610-678-8201 E-mail: [email protected] www.CRAIGG.com

12

SEE THE PAGE ON PARTIAL COVERS IF A CUSTOM SIZE IS REQUIRED OR IF PART OF THE PIT COVER IS TO REMAIN OPEN.

35-1/4"36"

41-3/16"42"

47-1/2"48"

53-5/8"54"

59-3/8"60"

65-5/16"66"

71-1/4"72"

# 2COVER

#1COVER

O/OLENGTHFRAM EACTUAL

LENGTHFRAM E

NOMINAL

C BAA

11-7/16"11-7/16"23-3/4"24"

17-3/8"11-7/16"29 -11/16"30"

23-5/16"11-7/16"

17-3/8"17-3/8"

29-1/4"11-7/16"

23-5/16"17-3/8"

35-3/16"11-7/16"

29-1/4"17-3/8"

23-5/16"23-5/16"

41-1/8"11-7/16"

35-3/16"17-3/8"29-1/4"23-5/16"

47-1/16"11-7/16"

41-1/8"17-3/8"35-3/16"23-5/16"29-1/4"29-1/4"

53"11-7/16"

47-1/16"17-3/8"41-1/8"23-5/16"

35-3/16"29-1/4"59-7/32"11-7/16"53-9/32"17-3/8"47-1/16"23-5/16"41-1/8"29-1/4"

35-3/16"35-3/16"

Cover # 1 Cover # 2

Two Piece covers allows the frame to be divided into two standard covers. This cover arrangement is beneficial when limited access to the opening is needed or reducing the size of the covers will allow for easier removal.

Any type, finish or style of covers can be paired together.

COVER COMBINATIONS

Page 26: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

Section 8-6

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures

Phone: 610-678-8200 Fax: 610-678-8201 E-mail: [email protected] www.CRAIGG.com

12

Cover Supports are recommended on larger covers or those subjected to heavier loading and/or traffic.

Cover Supports are recommended on covers over 30” square or on partial covers where one edge does not rest on the frame and is subject to traffic weight.

NOTE:

Pit covers and frames are engineered for light and medium surface loads that are usually applied with their indoor use.

Calculations are based on:

Covers informally loaded.

All four edges being supported.

A maximum deflection of L/150 of the short side. Maximum allowed shear strength is greater.

Cover supports are used to strengthen plate and reduce the deflection rate. No strength ratings are available for this configuration.

TENSION SUPPORTCOVER SUPPORT

COVER PLATE

Craigg Manufacturing assumes no responsibility for the accuracy or complete-ness of these tables which are supplied solely as a convenience to the user.

COVER PLATE STRENGTH RATINGS LBS. PER SQ. FT.

SHORTEST SPANSPAN

LONGEST

THICKNESSPLATECOVER

1/4"

3/8"

4'-0"3'-6"3'-0"2'-6"2'-0"1-6"1'-0"

19591'-0"

58010221-6"

2453557782'-0"

1241602747052'-6"

72881302306483'-0"

4655721092166333'-6"

30364560942026194'-0"

66101'-0"

196034851-6"

820121026502'-0"

41555092224002'-6"

24530043078522003'-0"

15518724536072021403'-6"

10412115120231769121004'-0"

Page 27: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

The TWO PART frame consist of two independent adjustable frames that fit into one base frame. Two smaller frames and covers can be used for gaining access that will not compromise the units strength. This is especially beneficial when part of the unit is inaccessible in its location. Each frame can be independently adjusted to accommodate differences in flooring type thicknesses. The TWO PART frame adds flexibility in that both frames do not have to be of equal size. Any cover type and style can be used independently along with partial covers on the Two Part Frame

Section 9-1

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures

Phone: 610-678-8200 Fax: 610-678-8201 E-mail: [email protected] www.CRAIGG.com

12

Two Part Frame Assembly

Fig. 9.1

Available with Liner or Frame Only

Install as you would the MODEL ADL in Section 2 if a liner is utilized or the MODEL ADF in Section 4 if for the frame only Sizing unit is accomplished by : FIRST by selecting the overall frame size needed using the dimension information chart of the Model ADF section 4-2 SECOND by selecting the aluminum frame sizes needed for the both halves from Model RCF section 5-2. Each half can be of a different size totaling the overall dimension. THIRD Choose the approvable cover size and type from Cover section 8-1, 8-2, 8-3

Page 28: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

POURED FLOOR LINE

B

A

FORMING SUPPORT TAB

ADJUSTOR NUT

JAM NUT

STEEL BASE FRAME CAN BE SET FROM 2-7/8" TO 4" BELOW FINISHED FLOOR LINE

C

SELECT COVERS FROM SECTION 8

ADJUSTOR NUT

JAM NUT

POURED FLOOR LINE

E

D

FRAME SHOWN AT MINIMUM ADJUSTMENT

SELECT COVERS FROM SECTION 8

Section 9-2

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures

Phone: 610-678-8200 Fax: 610-678-8201 E-mail: [email protected] www.CRAIGG.com

12

The two part frame consist of two independent adjustable frames that fit into one base frame. Two smaller frames and covers can be used for gaining access that will not compromise the units strength this is especially beneficial when part of the unit is inaccessible. Each frame can be independently adjusted to ac-commodate differences in flooring type.

Partial covers can also be used in conjunction with the Two Part Frame

Two Part Frame Assembly

Fig. 9.2

BOTH FRAMES DO NOT HAVE TO BE OF EQUAL SIZE OR COVER STYLE

For Installation of this unit use the ADL in section 2 or the ADF in section 4

W IDTH OR LENGTH OF ALUMINUM FRAM E "A" OR "B" OR "C"

W IDTH OR LENGTH OF INSIDE W ALL OF FIELD FORMED PIT - "D" OR "E"

96"90"84"78"72"66"60"54"48"42"36"30"24"18"12"NOMINAL SIZE

95"89-1/16"83-1/8"77-3/16"71-1/4"65-5/16"59-3/8"53-7/16"47-1/2"41-9/16"35-5/8"29-11/16"23-3/4"17-13/16"11-7/8"ACTUAL SIZE

93-1/8"87-3/16"81-1/4"75-5/16"69-3/8"63-7/16"57-1/2"51-9/16"47-5/8"39-11/16"33-3/4"27-13/16"21-7/8"15-15/16"10"

Manufactured sizes shown. Custom sizes also available.

DIMENSIONAL INFORMATION

Inside of Pit Wall

Page 29: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

The APL unit is designed for areas that have limited available access area but requires the need for a larger pit. The first half utilizes our standard Model ADL frame with your choice of cover type, the balance of the unit is tied in with the poured floor.

Units are available in nominal 6 inch increments in length ,width and depth.

Sizing unit is accomplished by : FIRST by selecting the overall unit size needed using either the dimension information chart of the Model ADL section 2-2 or the Model POL section 3-2. SECOND selecting the aluminum frame size needed for the accessible side from Model RCF section 5-2. THIRD Choose the cover size and type from Cover section 8-1, 2, 3

POURED FLOOR

FINE AGGREGATE OR SAND

FRAME ANCHORMUST BE CAST IN CONCRETE

COMPOSITE LINER

LINER SECURING RODS

EARTH

ALLOW PROPER CLEARANCEFOR FLOORING MATERIAL

20 GA. GALVANIZED

CONTINOUS POUR COVER

20 GA. GALVANIZED

CONTINOUS POUR COVER AREA

LEAVE PROTECTIVE FILM ON THE ALUMINUM FRAME FOR PROTECTION

Section 9-3

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures

Phone: 610-678-8200 Fax: 610-678-8201 E-mail: [email protected] www.CRAIGG.com

12

Fig. 9.1

Fig. 9.2 Fig. 9.3

Combination Adjustor and Pourover Frame & Liner

Available with Liner or Frame Only

COVER

Page 30: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

The APD unit is designed for areas that would benefit from the unit placed at an angle. The larger pit allows for ample working space and better under ground access. The triangular finished frame is placed 90 degrees to the setting position. The accessible frame section utilizes our standard Model ADL frame with your choice of cover type, the bal-ance of the unit is tied in with the poured floor.

Units are available in nominal 6 inch increments in length ,width and depth.

Sizing unit is accomplished by : FIRST by selecting the overall unit size needed using either the dimension information chart of the Model ADL section 2-2 or the Model POL section 3-2. SECOND by selecting the aluminum frame size needed for the accessible side. THIRD Choose the cover size and type from Cover section 8-1,2,3

POURED FLOOR

FINE AGGREGATE OR SAND

FRAME ANCHORMUST BE CAST IN CONCRETE

COMPOSITE LINER

LINER SECURING RODS

EARTH

ALLOW PROPER CLEARANCEFOR FLOORING MATERIAL

20 GA. GALVANIZED

CONTINOUS POUR COVER

20 GA. GALVANIZED

CONTINOUS POUR COVER AREA

LEAVE PROTECTIVE FILM ON THE ALUMINUM FRAME FOR PROTECTION

Section 9-4

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures

Phone: 610-678-8200 Fax: 610-678-8201 E-mail: [email protected] www.CRAIGG.com

12

Fig. 9.1

Fig. 9.2 Fig. 9.3

Angled Adjustor and Pourover Frame & Liner

COVER POUR OVER

A A

CHOOSE A COVER POUR OVER

SECTION A-A

Available with Liner or Frame Only

Page 31: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

The APA unit allows access from either end when the center section is obstructed. This pit allows for pass through con-venience of mechanicals. Units are available in any of our nominal sizes in 6 inch increments in length ,width and depth. Sizing unit is accomplished by : FIRST by selecting the overall unit size needed using either the dimension information chart of the Model ADL section 2-2 or the Model POL section 3-2. SECOND by selecting the aluminum frame size needed for both accessible sides. Each can be different section 3-2 Model RCF can provide this information THIRD Choose the cover size and type from Cover section 8-1,2,3

POURED FLOOR

FINE AGGREGATE OR SAND

FRAME ANCHORMUST BE CAST IN CONCRETE

COMPOSITE LINER

LINER SECURING RODS

EARTH

ADLPOURED FLOOR LINE

ADJUST FOR FLOORINGCOVER SELECTION

IN SECTION 8MATERIAL AFTER POUR

POL ADLPOURED COVER

Section 9-5

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures

Phone: 610-678-8200 Fax: 610-678-8201 E-mail: [email protected] www.CRAIGG.com

12

Fig. 9.1

Fig. 9.2

Double End Adjustor with Pourover Center Frame & Liner

Available with Liner or Frame Only

Can remain open using the provided wood pourstop or poured over

Page 32: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

The APO unit is designed for areas that allows a partition wall to cross over the pit . Access at the wall can be either inside the wall or behind it . This solid base under the wall can then be properly sealed to avoid liquids entering the pit .The removable cover still makes it accessible.

Units are available in any of our nominal sizes in 6 inch increments in length ,width and depth.

Sizing unit is accomplished by : FIRST by selecting the overall unit size needed using either the dimension information chart of the Model ADL section 2-2 or the Model POL section 3-2. SECOND selecting the aluminum frame size needed for the accessible side from Model RCF section 5-2. then choose the cover size and type from Cover section 8-1,2,3 THIRD In the remaining opening determine the poured cover size and needed opening area.

Section 9-6

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures

Phone: 610-678-8200 Fax: 610-678-8201 E-mail: [email protected] www.CRAIGG.com

12

Fig. 9.2

Fig. 9.1

Combination Adjustor ,Pourover and Open Area Frame & Liner

Available with Liner or Frame Only

OPEN AREAUNDER WALL

POURED COVERAREA

WOOD FORMREMOVE AFTER POUR

CHOOSE COVER FOR YOUR NEEDS

FORMING SUPPORT TABSBEND DOWN AFTER POUR

20 GA. GALVANIZED

POURED FLOOR

FINE AGGREGATE OR SAND

FRAME ANCHORMUST BE CAST IN CONCRETE

COMPOSITE LINER

LINER SECURING RODS

EARTH

FRAME

ALLOW PROPER CLEARANCEFOR FLOORING MATERIAL

WO

OD

FO

RM

POU

RED

CO

VER

AREA

Page 33: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

WOOD FORM

POURED COVER AREA

Section 9-7

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures

Phone: 610-678-8200 Fax: 610-678-8201 E-mail: [email protected] www.CRAIGG.com

12

Fig. 9.5

Fig. 9.3

WO

OD

FO

RM

POU

RED

CO

VER

AREA

Fig. 9.4

Combination Adjustor ,Pourover and Open Area Frame & Liner

POURED COVER

RO

OM

FO

R P

IPIN

G

RO

OM

FO

R P

IPIN

G

WALL

COVER IN PLACE

POLADL

OPEN

Field SuppliedEntry

If Required

POURED FLOOR

FINE AGGREGATE OR SAND

FRAME ANCHORMUST BE CAST IN CONCRETE

COMPOSITE LINER

LINER SECURING ROD

EARTH

Page 34: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

POURED FLOOR

AGGREGATE OR SAND

FRAME ANCHORMUST BE CAST IN CONCRETE

COMPOSITE LINER

LINER SECURING ROD

EARTH

BUILDING'sPOURED FOUNDATION

WALL

MODEL POLW

OR

MODEL ADLW

WALL

Field SuppliedEntry

If Required

Section 9-8

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures

Phone: 610-678-8200 Fax: 610-678-8201 E-mail: [email protected] www.CRAIGG.com

12

Fig. 9.1

Fig. 9.2

The “W” unit design is so that one or more sides will have a minimum amount of frame structure to interfere with its installation against a wall. The prime location for its use is along an exterior foundation wall or a partition wall. This allows any vertical entrances into the pit to stay tight against the wall. The “W” unit is available in both MODELS ADL and POL and in all of our manufactured sizes.

Flush Mounting Unit Frame & Liner

Page 35: In-Floor Access Enclosures - Craiggpoured floor fine aggregate or sand frame anchor must be cast in concrete composite liner liner securing rods earth with the upper frame being adjustable

The CLL is another of our One Step installation units. The CLL’s sim-pler design proves it still can provide you a solid and attractive in-floor unit. It does limit the choice of cover types and finishes to Flush Mill or Treadplate in steel or aluminum. Like all of our units the liner is made of a heavy composite material that incorporates a sturdy steel supporting frame. The concrete floor area surrounding pit is poured flush with the finished cover.

Units are available in all our nominal sizes in 6 inch increments in length, width

and depth.

Size unit from the dimension information chart of the Model ADL section 2-2

Cover selection is limited to the Cover Styles shown on Section 8-3 Flush Covers

POURED FLOOR

FINE AGGREGATE OR SAND

COMPOSITE LINER

EARTH

A

Section 9-9

Craigg Manufacturing Corp. Manufacturers of In-Floor Access Enclosures

Phone: 610-678-8200 Fax: 610-678-8201 E-mail: [email protected] www.CRAIGG.com

12

Fig. 9.2

Fixed Cover with Frame & Liner

Fig. 9.1 Clear Access Dimensions

Pit Size A"

18" 17"

24" 23"

30" 29"

36" 34 3/4"

42" 41"

48" 47"

54" 53"

60" 59"

66" 65"

72" 71"