In-Line Cell Manager Configuration and Loading
Date: Octobre2014
![Page 2: In-Line Cell Manager Configuration and Loading Date: Octobre2014](https://reader036.vdocuments.net/reader036/viewer/2022062516/56649de35503460f94ad9f53/html5/thumbnails/2.jpg)
2
Cell Manager Configuration Module
• CoreView In Line Software consists of two main Modules• Measurement Unit (CoreView Teach for In-Line)• Cell Manager
• On each computer which is connected to the WLS400A system, the Measurement Unit is installed
• The Cell manager is installed on one of the units computer.
• In-Line configuration of both Units and the Cell Manager is done through a configuration module: C:\Cognitens\bin64\Inline.Configuration.UI.exe which is executed in the Cell Manager Unit.
![Page 3: In-Line Cell Manager Configuration and Loading Date: Octobre2014](https://reader036.vdocuments.net/reader036/viewer/2022062516/56649de35503460f94ad9f53/html5/thumbnails/3.jpg)
3
Configuration Interface
Computer Name
Cell NameHas to be the same in all Cell Units
Unit Name
Press for Cell Manager Configuration
Important:Don’t forget to press Apply after you finish with all the configuration.
![Page 4: In-Line Cell Manager Configuration and Loading Date: Octobre2014](https://reader036.vdocuments.net/reader036/viewer/2022062516/56649de35503460f94ad9f53/html5/thumbnails/4.jpg)
4
Cell Manager Configuration
Path to result file generated in XML format. (For Back compatibility)
![Page 5: In-Line Cell Manager Configuration and Loading Date: Octobre2014](https://reader036.vdocuments.net/reader036/viewer/2022062516/56649de35503460f94ad9f53/html5/thumbnails/5.jpg)
5
Cell Manager Configuration
GateWay Computer IP Address
![Page 6: In-Line Cell Manager Configuration and Loading Date: Octobre2014](https://reader036.vdocuments.net/reader036/viewer/2022062516/56649de35503460f94ad9f53/html5/thumbnails/6.jpg)
6
Cell Manager Configuration
Currently only Diagnostic report is supported
![Page 7: In-Line Cell Manager Configuration and Loading Date: Octobre2014](https://reader036.vdocuments.net/reader036/viewer/2022062516/56649de35503460f94ad9f53/html5/thumbnails/7.jpg)
7
Cell Manager Configuration
No Change Required
![Page 8: In-Line Cell Manager Configuration and Loading Date: Octobre2014](https://reader036.vdocuments.net/reader036/viewer/2022062516/56649de35503460f94ad9f53/html5/thumbnails/8.jpg)
8
Configuration Interface
Press to configure Units
Important:Don’t forget to press Apply after you finish with all the configuration.
![Page 9: In-Line Cell Manager Configuration and Loading Date: Octobre2014](https://reader036.vdocuments.net/reader036/viewer/2022062516/56649de35503460f94ad9f53/html5/thumbnails/9.jpg)
9
Unit Configuration
Full Path to local CTP. Including computer nameMultiple CTP supported
![Page 10: In-Line Cell Manager Configuration and Loading Date: Octobre2014](https://reader036.vdocuments.net/reader036/viewer/2022062516/56649de35503460f94ad9f53/html5/thumbnails/10.jpg)
10
Unit Configuration
DataServer Computer name. IP address is also supported
![Page 11: In-Line Cell Manager Configuration and Loading Date: Octobre2014](https://reader036.vdocuments.net/reader036/viewer/2022062516/56649de35503460f94ad9f53/html5/thumbnails/11.jpg)
11
Unit Configuration
No Change Required
![Page 12: In-Line Cell Manager Configuration and Loading Date: Octobre2014](https://reader036.vdocuments.net/reader036/viewer/2022062516/56649de35503460f94ad9f53/html5/thumbnails/12.jpg)
12
Unit Configuration
Full path to Bundle Folder. Has to be the same on both units
![Page 13: In-Line Cell Manager Configuration and Loading Date: Octobre2014](https://reader036.vdocuments.net/reader036/viewer/2022062516/56649de35503460f94ad9f53/html5/thumbnails/13.jpg)
13
Load In-Line Measurement System
• To Load the In-Line Measurement System run: C:\Cognitens\bin64\Inline.Cell.UI.exe
• The In-Line Cell UI enables:• Loading\Unloading all the Measurement In-Line process• Review the existing bundles and set the Delete option for
the output data (this includes all the images and point cloud)
• Once the Loading off all the processes is done the system is ready to execute In-Line measurement process
![Page 14: In-Line Cell Manager Configuration and Loading Date: Octobre2014](https://reader036.vdocuments.net/reader036/viewer/2022062516/56649de35503460f94ad9f53/html5/thumbnails/14.jpg)
14
Load In-Line Measurement System – Bundle Configuration
Red Bundles are marked Not to delete automatically
This will delete the outputs on both computers after the results are generated
Use this to delete existing outputs which were not deleted automatically
![Page 15: In-Line Cell Manager Configuration and Loading Date: Octobre2014](https://reader036.vdocuments.net/reader036/viewer/2022062516/56649de35503460f94ad9f53/html5/thumbnails/15.jpg)
15
Load In-Line Measurement System
Press to start the process
![Page 16: In-Line Cell Manager Configuration and Loading Date: Octobre2014](https://reader036.vdocuments.net/reader036/viewer/2022062516/56649de35503460f94ad9f53/html5/thumbnails/16.jpg)
16
Load In-Line Measurement System
Press to Stop the process
All Process have to be Green and ReadyAnd Cell Manager Connected to GateWay