incinerator air blower repetitive failures · furnace inlet silencer inlet air filter motor igv...
TRANSCRIPT
![Page 1: Incinerator Air Blower Repetitive Failures · Furnace Inlet silencer Inlet Air Filter Motor IGV Secondary Air 29-K003 to 29-F003 Furnace ... New Blower FAT Page 15/20 . New Blower](https://reader034.vdocuments.net/reader034/viewer/2022051809/6011a30ec06ffa451f7581e3/html5/thumbnails/1.jpg)
Incinerator Air Blower
Repetitive Failures
Authors : RasGas Company Limited
Pradip B Sonavane Mohamed H. Abdel Khalek
Sr. Eng. (Rotating Machinery) Advisor (Rotating Machinery)
![Page 2: Incinerator Air Blower Repetitive Failures · Furnace Inlet silencer Inlet Air Filter Motor IGV Secondary Air 29-K003 to 29-F003 Furnace ... New Blower FAT Page 15/20 . New Blower](https://reader034.vdocuments.net/reader034/viewer/2022051809/6011a30ec06ffa451f7581e3/html5/thumbnails/2.jpg)
• Sharing trouble shooting / experience on blower
failures.
• To address similar issues / failures due to over-size /
over-capacity equipments
• Reference for blowers selection at project stage.
Objectives
Page 2/20
![Page 3: Incinerator Air Blower Repetitive Failures · Furnace Inlet silencer Inlet Air Filter Motor IGV Secondary Air 29-K003 to 29-F003 Furnace ... New Blower FAT Page 15/20 . New Blower](https://reader034.vdocuments.net/reader034/viewer/2022051809/6011a30ec06ffa451f7581e3/html5/thumbnails/3.jpg)
Problem
Event Summary
Observations and Findings
Root Cause Failure Factors
Solutions
Selection and Implementation
New Blower – Site Performance
Lessons Learnt
Conclusion
Contents
Page 3/20
![Page 4: Incinerator Air Blower Repetitive Failures · Furnace Inlet silencer Inlet Air Filter Motor IGV Secondary Air 29-K003 to 29-F003 Furnace ... New Blower FAT Page 15/20 . New Blower](https://reader034.vdocuments.net/reader034/viewer/2022051809/6011a30ec06ffa451f7581e3/html5/thumbnails/4.jpg)
Problem
• Low discharge pressure and abnormal sound.
• High casing and inlet duct vibration, whereas bearing
vibrations were normal.
• Multiple cracks on casing internal partitions, diffuser
rings and IGVs.
• Crack and rubbing marks on rotor impeller.
Page 4/20
![Page 5: Incinerator Air Blower Repetitive Failures · Furnace Inlet silencer Inlet Air Filter Motor IGV Secondary Air 29-K003 to 29-F003 Furnace ... New Blower FAT Page 15/20 . New Blower](https://reader034.vdocuments.net/reader034/viewer/2022051809/6011a30ec06ffa451f7581e3/html5/thumbnails/5.jpg)
• Blower was commissioned in 2007.
• High vibration was found in the furnace during
commissioning time, and warranty claim was raised.
• Furnace high vibration warranty claim issue closed
during commissioning by reducing 50% of blower
capacity.
• Three failures occurred as:
→ 2009 : Catastrophic failure
→ 2011 : Major failure
→ 2013 : Minor failure
• Failure description: Complete casing internal, discharge
duct, IGV blades found cracked and dislocated. Plus
surface crack on impeller.
Events’ Summary
Page 5/20
![Page 6: Incinerator Air Blower Repetitive Failures · Furnace Inlet silencer Inlet Air Filter Motor IGV Secondary Air 29-K003 to 29-F003 Furnace ... New Blower FAT Page 15/20 . New Blower](https://reader034.vdocuments.net/reader034/viewer/2022051809/6011a30ec06ffa451f7581e3/html5/thumbnails/6.jpg)
Equipment Details Incinerator Air Blower (Sulfur Recovery)
Type : Centrifugal Fan, double side suction
Driver : Motor
Rated Power : 930 KW
RPM : 1500
Rated Flow : 4830 M3/Min.
Suc. Pressure : Atm
Disch. Pressure : 630 mm H2O G
Rotor Length & Wheel Dia. : 4215 & 1680 mm
Primary Air
to 29-F003
Furnace
Inlet silencer
Inlet Air
Filter
Motor
IGV
29-K003
Secondary Air
to 29-F003
Furnace
Discharge
Silencer
FT
FCV
FT FCV
furnace operation -
flow control
Page 6/20
![Page 7: Incinerator Air Blower Repetitive Failures · Furnace Inlet silencer Inlet Air Filter Motor IGV Secondary Air 29-K003 to 29-F003 Furnace ... New Blower FAT Page 15/20 . New Blower](https://reader034.vdocuments.net/reader034/viewer/2022051809/6011a30ec06ffa451f7581e3/html5/thumbnails/7.jpg)
Observations and Findings
Casing internal damages / cracks
Page 7/20
![Page 8: Incinerator Air Blower Repetitive Failures · Furnace Inlet silencer Inlet Air Filter Motor IGV Secondary Air 29-K003 to 29-F003 Furnace ... New Blower FAT Page 15/20 . New Blower](https://reader034.vdocuments.net/reader034/viewer/2022051809/6011a30ec06ffa451f7581e3/html5/thumbnails/8.jpg)
Observations and Findings
IGV blade broken Broken blade inside casing
Page 8/20
![Page 9: Incinerator Air Blower Repetitive Failures · Furnace Inlet silencer Inlet Air Filter Motor IGV Secondary Air 29-K003 to 29-F003 Furnace ... New Blower FAT Page 15/20 . New Blower](https://reader034.vdocuments.net/reader034/viewer/2022051809/6011a30ec06ffa451f7581e3/html5/thumbnails/9.jpg)
• Blower operation in unstable region (surge
conditions), leading to resonance and cyclic fatigue.
• Insufficient surge protection control system.
• IGV system used for furnace flow demand not for
blower surge protection.
Root Cause Failure Factors
Page 9/20
![Page 10: Incinerator Air Blower Repetitive Failures · Furnace Inlet silencer Inlet Air Filter Motor IGV Secondary Air 29-K003 to 29-F003 Furnace ... New Blower FAT Page 15/20 . New Blower](https://reader034.vdocuments.net/reader034/viewer/2022051809/6011a30ec06ffa451f7581e3/html5/thumbnails/10.jpg)
Root Cause Failure Factors
Page 10/20
![Page 11: Incinerator Air Blower Repetitive Failures · Furnace Inlet silencer Inlet Air Filter Motor IGV Secondary Air 29-K003 to 29-F003 Furnace ... New Blower FAT Page 15/20 . New Blower](https://reader034.vdocuments.net/reader034/viewer/2022051809/6011a30ec06ffa451f7581e3/html5/thumbnails/11.jpg)
Solutions : Available options
Install surge protection
system - blow-off valve
Blower rerate: New blower
with required capacity
Trim existing blower
impeller
Motor upgrade to
variable speed
Repair and restore
(Selected Option)
Page 11/20
1 Or
2
3
4
5
Or
Or
Or
![Page 12: Incinerator Air Blower Repetitive Failures · Furnace Inlet silencer Inlet Air Filter Motor IGV Secondary Air 29-K003 to 29-F003 Furnace ... New Blower FAT Page 15/20 . New Blower](https://reader034.vdocuments.net/reader034/viewer/2022051809/6011a30ec06ffa451f7581e3/html5/thumbnails/12.jpg)
Selection and Implementation
Blower Rerate:-
• New blower max capacity is 3066 m3/min (old was
4830 m3/min).
• No major site modification:
1. Same foot print, coupling and suction and discharge
duct with transition pieces.
2. Existing motor.
3. No change in air inlet filtration unit.
Page 12/20
![Page 13: Incinerator Air Blower Repetitive Failures · Furnace Inlet silencer Inlet Air Filter Motor IGV Secondary Air 29-K003 to 29-F003 Furnace ... New Blower FAT Page 15/20 . New Blower](https://reader034.vdocuments.net/reader034/viewer/2022051809/6011a30ec06ffa451f7581e3/html5/thumbnails/13.jpg)
New Blower Performance Curve
Page 13/20
![Page 14: Incinerator Air Blower Repetitive Failures · Furnace Inlet silencer Inlet Air Filter Motor IGV Secondary Air 29-K003 to 29-F003 Furnace ... New Blower FAT Page 15/20 . New Blower](https://reader034.vdocuments.net/reader034/viewer/2022051809/6011a30ec06ffa451f7581e3/html5/thumbnails/14.jpg)
New Blower Drawing
Page 14/20
![Page 15: Incinerator Air Blower Repetitive Failures · Furnace Inlet silencer Inlet Air Filter Motor IGV Secondary Air 29-K003 to 29-F003 Furnace ... New Blower FAT Page 15/20 . New Blower](https://reader034.vdocuments.net/reader034/viewer/2022051809/6011a30ec06ffa451f7581e3/html5/thumbnails/15.jpg)
New Blower FAT
Page 15/20
![Page 16: Incinerator Air Blower Repetitive Failures · Furnace Inlet silencer Inlet Air Filter Motor IGV Secondary Air 29-K003 to 29-F003 Furnace ... New Blower FAT Page 15/20 . New Blower](https://reader034.vdocuments.net/reader034/viewer/2022051809/6011a30ec06ffa451f7581e3/html5/thumbnails/16.jpg)
New Blower - Site Performance
Page 16/20
IGV opening Motor current (Amps) Flow (Nm3/hrs) Disch. press (mbarg)
% DCS / degree local 29FC-0561 29FC-0562 29PC-0561
00% / 00̊ 26 27 27 28500 5.5
23% / 18˚ 31 31 31 62000 6.61
35% / 30˚ 35 35 35 70000 25000 39.36
50% / 45˚ 42 42 42 66200 87700 34.44
70% / 63˚ 43 43 43 67500 104600 35.36
100% / 90˚ 43 43 43 66500 111200 34.24
Measurement points IGV 30̊
open
IGV 63̊
open
IGV 90̊
open
Back to IGV
45̊ open
After 24hrs
running with
IGV 45̊ open
Elect motor
Casing- NDE horizontal (mm/s) 0.75 0.77 0.82 0.75 0.75
Casing- NDE vertical (mm/s) 0.28 0.26 0.24 0.25 0.2
Casing- DE horizontal (mm/s) 0.7 0.77 0.78 0.73 0.68
Casing- DE vertical (mm/s) 0.3 0.34 0.3 0.4 0.3
Casing- DE axial (mm/s) 0.38 0.39 0.38 0.35 0.37
Blower
Casing- DE horizontal (mm/s) 0.58 0.76 0.8 0.7 0.6
Casing- DE vertical (mm/s) 0.34 0.5 0.5 0.45 0.4
Casing- NDE horizontal (mm/s) 0.63 0.53 0.55 0.5 0.4
Casing- NDE vertical (mm/s) 0.37 0.38 0.4 0.44 0.5
Casing- NDE axial (mm/s) 0.3 0.4 0.35 0.4 0.3
Operation data
Vibration data
![Page 17: Incinerator Air Blower Repetitive Failures · Furnace Inlet silencer Inlet Air Filter Motor IGV Secondary Air 29-K003 to 29-F003 Furnace ... New Blower FAT Page 15/20 . New Blower](https://reader034.vdocuments.net/reader034/viewer/2022051809/6011a30ec06ffa451f7581e3/html5/thumbnails/17.jpg)
New Blower Operating Point
Page 17/20
New Blower normal continuous operation is at: • Flow = 85 to 95 KNm3/hr (1416 to 1583 Nm3/min) and
• Dish Pressure = 40 mbarG (407.89 mmAq)
![Page 18: Incinerator Air Blower Repetitive Failures · Furnace Inlet silencer Inlet Air Filter Motor IGV Secondary Air 29-K003 to 29-F003 Furnace ... New Blower FAT Page 15/20 . New Blower](https://reader034.vdocuments.net/reader034/viewer/2022051809/6011a30ec06ffa451f7581e3/html5/thumbnails/18.jpg)
Lessons Learnt
1. Blower operation below rated capacity near minimum flow region in
response to downstream requirement is not good practice; unless
blower surge control protection system is in place.
2. Blower casing and suction duct vibration, resonance monitoring beyond
bearing vibrations must be part of preventive maintenance programmed.
3. Blower and duct internals strengthening by adding stiffeners resulted
effectively in reducing resonance effects as an immediate / short term
measures.
4. Process load conditions, driver selection, equipment capacity / sizing
aspects needs to be carefully analyzed during project stage.
5. Project control (MAC, SAT, handover) are critical for project to be
successful.
Page 18/20
![Page 19: Incinerator Air Blower Repetitive Failures · Furnace Inlet silencer Inlet Air Filter Motor IGV Secondary Air 29-K003 to 29-F003 Furnace ... New Blower FAT Page 15/20 . New Blower](https://reader034.vdocuments.net/reader034/viewer/2022051809/6011a30ec06ffa451f7581e3/html5/thumbnails/19.jpg)
Conclusion
• New blower assembled and commissioned successfully
in March 2014.
• No site modification.
• Blower resonance and high vibration issues have been
resolved.
• Blower performance found satisfactory in all mode of
furnace operation.
Page 19/20
![Page 20: Incinerator Air Blower Repetitive Failures · Furnace Inlet silencer Inlet Air Filter Motor IGV Secondary Air 29-K003 to 29-F003 Furnace ... New Blower FAT Page 15/20 . New Blower](https://reader034.vdocuments.net/reader034/viewer/2022051809/6011a30ec06ffa451f7581e3/html5/thumbnails/20.jpg)
Thank You