increased safety lighting - thorne and derrick uk · increased safety lighting fixtures for bi-pin...

4
YOUR PARTNER FOR SAFETY Since 1961 Explosion Proof Electrical Equipment AVC AVC Feam Catalogue 03 - 1 Ex Lighting ON REQUEST ACCESSORIES: • Pole mounting kit complete with stainless steel hardware • Ceiling mounting kit complete with stainless steel hardware • Pendant mounting kit complete with stainless steel hardware • Wall/Structure mounting kit complete with stainless steel hardware • Electronic ballast with voltage supply different than standard • Voltage different than standard Mechanical characteristics Body galss fibre reinforced polyester resin self-extinguishing acc. to UL94 Diffuser U/V resistant polycarbonate - hinged to body Safety closing operated by hexagonal key Gaskets EPDM 60 rubber suitable for high temperatures and resistant to enviroments conditions Internal reflector white stove enamelled sheet aluminum Cable entry ISO-Metric complete with cable glands and plug Electrical characteristics Power supply elettronic ballast 96...254V AC 50/60Hz (cos ρ ≥ 0,95) Lampholders bi-pin G13 cap Internal wiring high-temperature resistant silicon rubber insulation cables Terminals suitable up to 4 sq/mm cables Safety feature with protections against over charge and over discharge INCREASED SAFETY LIGHTING FIXTURES FOR BI-PIN FLUORESCENT LAMPS Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D LIGHTING FIXTURE ATEX 94/9/EC IEC Ex INMETRO GOST-R EXECUTION II 2 G Ex d e q IIC T4 Gb II 2 D Ex tb IIIC T80°C Db Ex d e q IIC T4 Gb Ex tb IIIC T80°C Db Ex d e q IIC T4 Gb Ex tb IIIC T80°C Db Ex d e q IIC T4 Gb X Ex tb IIIC T80°C Db AMBIENT TEMPERATURE -20°C ÷ +60°C -20°C ÷ +60°C -20°C ÷ +60°C -40°C ÷ +55°C PROTECTION DEGREE IP66 IP66 IP66 IP66 CERTIFICATE REF. LCIE 12 ATEX 3050X - - POCC IT. ME92.B02923 RULES OF COMPLIANCE IEC 60079-0 Ed.6; EN 60079-1:2007; EN 60079-5:2007; EN 60079-07:2007; EN 60079-31:2009; IEC 60079-0; IEC 60079-1; IEC 60079-31; IEC 60079-5; IEC 60079-7; ABNT NBR IEC 60079-0; ABNT NBR IEC 60079-1; ABNT NBR IEC 60079-31; ABNT NBR IEC 60079-5; ABNT NBR IEC 60079-7; ГОСТ Р МЭК 60079-0:2011; ГОСТ Р МЭК 61241-0:2007; ГОСТ Р МЭК 61241-1:2004; EMERGENCY UNIT ATEX 94/9/EC IEC Ex INMETRO GOST-R EXECUTION II 2 G Ex d e q IIC T4 Gb II 2 D Ex tb IIIC T80°C Db Ex d e q IIC T4 Gb Ex tb IIIC T80°C Db Ex d e q IIC T4 Gb Ex tb IIIC T80°C Db Ex d e q IIC T4 Gb X Ex tb IIIC T80°C Db AMBIENT TEMPERATURE -20°C ÷ +60°C -20°C ÷ +60°C -20°C ÷ +60°C -40°C ÷ +55°C PROTECTION DEGREE IP66 IP66 IP66 IP66 CERTIFICATE REF. LCIE 12 ATEX 3050X - - POCC IT. ME92.B02923 RULES OF COMPLIANCE IEC 60079-0 Ed.6; EN 60079-1:2007; EN 60079-5:2007; EN 60079-07:2007; EN 60079-31:2009; IEC 60079-0; IEC 60079-1; IEC 60079-31; IEC 60079-5; IEC 60079-7; ABNT NBR IEC 60079-0; ABNT NBR IEC 60079-1; ABNT NBR IEC 60079-31; ABNT NBR IEC 60079-5; ABNT NBR IEC 60079-7; ГОСТ Р МЭК 60079-0:2011; ГОСТ Р МЭК 61241-0:2007; ГОСТ Р МЭК 61241-1:2004;

Upload: tranduong

Post on 13-Feb-2019

220 views

Category:

Documents


0 download

TRANSCRIPT

YOUR PARTNER FOR SAFETY

Since 1961

Explosion Proof Electrical Equipment

AVC

AVC

Feam Catalogue 03 - 1

Ex Lighting

On REquEst ACCEssORiEs: •Polemountingkitcompletewithstainlesssteelhardware•Ceilingmountingkitcompletewithstainlesssteelhardware•Pendantmountingkitcompletewithstainlesssteelhardware

•Wall/Structuremountingkitcompletewithstainlesssteelhardware•Electronicballastwithvoltagesupplydifferentthanstandard•Voltagedifferentthanstandard

Mechanical characteristicsBody galssfibrereinforcedpolyesterresinself-extinguishingacc.toUL94Diffuser U/Vresistantpolycarbonate-hingedtobodySafetyclosing operatedbyhexagonalkeyGaskets EPDM60rubbersuitableforhightemperaturesandresistanttoenviromentsconditionsInternalreflector whitestoveenamelledsheetaluminumCableentry ISO-Metriccompletewithcableglandsandplug

Electrical characteristicsPowersupply elettronicballast96...254VAC50/60Hz(cosρ≥0,95)Lampholders bi-pinG13capInternalwiring high-temperatureresistantsiliconrubberinsulationcablesTerminals suitableupto4sq/mmcablesSafetyfeature withprotectionsagainstoverchargeandoverdischarge

inCREAsED sAFEtY LiGHtinG FiXtuREs FOR Bi-Pin FLuOREsCEnt LAMPs

installation: hazardousareas-Zone1/2(Gases)-Zone21/22(Dusts) Classification: GroupII-Category2G2D

LiGHtinG FiXtuREAtEX 94/9/EC iEC Ex inMEtRO GOst-R

EXECutiOn II2GExdeqIICT4GbII2DExtbIIICT80°CDb

ExdeqIICT4GbExtbIIICT80°CDb

ExdeqIICT4GbExtbIIICT80°CDb

ExdeqIICT4GbXExtbIIICT80°CDb

AMBiEnt tEMPERAtuRE -20°C÷+60°C -20°C÷+60°C -20°C÷+60°C -40°C÷+55°CPROtECtiOn DEGREE IP66 IP66 IP66 IP66CERtiFiCAtE REF. LCIE12ATEX3050X - - POCCIT.ME92.B02923

RuLEs OF COMPLiAnCE

IEC60079-0Ed.6;EN60079-1:2007;EN60079-5:2007;EN60079-07:2007;EN60079-31:2009;

IEC60079-0;IEC60079-1;IEC60079-31;IEC60079-5;

IEC60079-7;

ABNTNBRIEC60079-0;ABNTNBRIEC60079-1;ABNTNBRIEC60079-31;ABNTNBRIEC60079-5;ABNTNBRIEC60079-7;

ГОСТРМЭК60079-0:2011;ГОСТРМЭК61241-0:2007;ГОСТРМЭК61241-1:2004;

EMERGEnCY unitAtEX 94/9/EC iEC Ex inMEtRO GOst-R

EXECutiOn II2GExdeqIICT4GbII2DExtbIIICT80°CDb

ExdeqIICT4GbExtbIIICT80°CDb

ExdeqIICT4GbExtbIIICT80°CDb

ExdeqIICT4GbXExtbIIICT80°CDb

AMBiEnt tEMPERAtuRE -20°C÷+60°C -20°C÷+60°C -20°C÷+60°C -40°C÷+55°CPROtECtiOn DEGREE IP66 IP66 IP66 IP66CERtiFiCAtE REF. LCIE12ATEX3050X - - POCCIT.ME92.B02923

RuLEs OF COMPLiAnCE

IEC60079-0Ed.6;EN60079-1:2007;EN60079-5:2007;EN60079-07:2007;EN60079-31:2009;

IEC60079-0;IEC60079-1;IEC60079-31;IEC60079-5;

IEC60079-7;

ABNTNBRIEC60079-0;ABNTNBRIEC60079-1;ABNTNBRIEC60079-31;ABNTNBRIEC60079-5;ABNTNBRIEC60079-7;

ГОСТРМЭК60079-0:2011;ГОСТРМЭК61241-0:2007;ГОСТРМЭК61241-1:2004;

YOUR PARTNER FOR SAFETY

Since 1961

AVC

AVC118 705 222 134 450 7,50 4xM25x1,5 A

AVC136 1335 222 134 800 11,50 4xM25x1,5 A

AVC218 705 222 134 450 8,00 4xM25x1,5 A

AVC236 1335 222 134 800 12,00 4xM25x1,5 A

AVC118-E 705 222 134 450 9,00 4xM25x1,5 A

AVC136-E 1335 222 134 800 13,00 4xM25x1,5 A

AVC218-E 705 222 134 450 9,50 4xM25x1,5 A

AVC236-E 1335 222 134 800 13,50 4xM25x1,5 A

AVC118 1x18W T4 T80°C G13 4xM25x1,5 - - A

AVC136 1x36W T4 T80°C G13 4xM25x1,5 - - A

AVC218 2x18W T4 T80°C G13 4xM25x1,5 - - A

AVC236 2x36W T4 T80°C G13 4xM25x1,5 - - A

AVC118-E 1x18W T4 T80°C G13 4xM25x1,5 4.8V-4Ah 3h A

AVC136-E 1x36W T4 T80°C G13 4xM25x1,5 4.8V-4Ah 3h A

AVC218-E 2x18W T4 T80°C G13 4xM25x1,5 4.8V-4Ah 3h A

AVC236-E 2x36W T4 T80°C G13 4xM25x1,5 4.8V-4Ah 3h A

OPENCLOSE

D

A

8MA 8MAA

OPENCLOSE

C

M25

B

2 - Feam Catalogue 03

FLuOREsCEnt LiGHtinG FiXtuREs FOR sinGLE AnD tWin LAMPs - POWER suPPLY 96...254V AC 50/60Hz

EMERGEnCY FLuOREsCEnt LiGHtinG FiXtuREs FOR sinGLE AnD tWin LAMPs - POWER suPPLY 230/240V AC 50/60Hz

ExLighting

AVC technical data

CODE LAMP tEMPERAtuRE CLAss (GAs)

tEMPERAtuRE CLAss (Dusts) LAMPHOLDER CABLE

EntRYEMERGEnCY

unit AutOnOMY DEtAiL

AVC technical featuresCODE A [mm] B [mm] C [mm] D [mm] WEiGHt [Kg] CABLE EntRY DEtAiL

CODE A [mm] B [mm] C [mm] D [mm] WEiGHt [Kg] CABLE EntRY DEtAiL

Reference details

YOUR PARTNER FOR SAFETY

Since 1961

AVC

45°

250

OPENCLOSE

OPENCLOSE

OPEN

CLOS

E

OPEN

CLOS

E

Feam Catalogue 03 - 3

ExLighting

AVC installation and mounting details

Wall/structure mounting

Pole mounting Assemblig detail with pole (typical)

type 3

type 1 type 2

type 2.1

Ceiling mounting Pendant mounting

Pendant mountingtype 4

YOUR PARTNER FOR SAFETY

Since 1961

AVC

AVC218 AVC118AVC136

4 - Feam Catalogue 03

ExLighting

AVC with emergency unit (design and special features)

REMARK:Due to thedevelopmentof thenationaland international specificationsandof the technology, theabove technical characteristicsshowedonthisbulletincanbeconsideredasbindingonourconfirmationonly.

AVC Polar diagrams – photometric data

POLEMOUNTINGKIT(SIZE2”DIA.)C/WHARDWARE TYPE4 GALVANIZEDSTEEL

POLEMOUNTINGKIT(SIZE11/2”DIA.)C/WHARDWARE TYPE4 GALVANIZEDSTEEL

PENDANTPOLEMOUNTINGKITC/WHARDAREANDEYE-BOLTS TYPE2.1 STAINLESSSTEEL

PENDANTCHAINMOUNTINGKITC/WHARDAREANDEYE-BOLTS TYPE2 GALVANIZEDSTEEL

CEILINGMOUNTINGKITC/WHARDWARE TYPE1 GALVANIZEDSTEEL

DEsCRiPtiOn instALLAZiOn MAtERiAL