INDEX
SI.NO
EXPERIMENT DETAILS
PAGE
1
CYCLE I
SIMULATION OF SINGLE ACTING CYLINDER USING
DIFFERENCE METHODS
2-7
2
SIMULATION OF DOUBLE ACTING CYLINDER USING
DIFFERENCE METHODS
8-12
3
BASIC HYDRAULIC CIRCUITS [ LINEAR MOTION &
ROTARY MOTION ]
14-17
4
BASIC ELECTRO HYDRAULIC CIRCUITS [ LINEAR MOTION &
ROTARY MOTION ]
18-21
5
STUDY AND USE OF HYDRAULIC ELEMENTS
22
6
STUDY AND USE OF PNEUMATIC ELEMENTS
23
7
CYCLE II
SIMULATION OF LOGIC PNEUMATIC CIRCUITS
24-27
8
SIMULATION OF PNEUMATIC CIRCUIT FOR METER-IN &
METER-OUT 28-31
9
SIMULATION OF PNEUMATIC SEQUENCING CIRCUITS OF
A+
B+ A
- B
-
32-33
10
SIMULATION OF ELECTRO PNEUMATIC SEQUENCING
CIRCUITS
34-35
11
SIMULATION OF AUTOMATION STUDIO SOFTWARE
CIRCUITS
36-37
12
SIMULATION OF ELECTRO HYDRAULIC SEQUENCING
CIRCUITS USING MITSUBISHI PLC
38-40
13 SIMULATION OF ELECTRO PNEUMATIC SEQUENCING
CIRCUITS USING OMRON PLC
41-43
![Page 3: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/3.jpg)
2
EX NO: 1 A DATE :
SIMULATION OF SINGLE ACTING CYLINDER
USING DIRECT METHOD
AIM :
To construct a circuit to trigger the forward and return stock by single
acting cylinder using a leaver operated dcv( direct method ).
APPARATUS REQUIRED :
Single acting cylinder
3/2 leaver operated dcv
Connecting tubes
AIR SUPPLY :
Shop floor air control supply with pressure regulator ,
filter, lubricators.
PROCEDURE :
Draw the circuit diagram for direct triggering of single
acting cylinder.
Connect the cylinder ,3/2 lever operated DCV as per
the circuit diagram through FRL unit
Connect the air supply to distributer block .
Operate the circuit.
RESULT:
Thus a single acting cylinder is simulated in the direct method
with help of direction control valves
![Page 4: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/4.jpg)
3
![Page 5: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/5.jpg)
4
EX NO: 1 B DATE :
SIMULATION OF SINGLE ACTING CYLINDER
USING INDIRECT METHOD
AIM :
To actuate a single acting cylinder using pilot operated 3/2 dcv and
manually actuated 3/2 dcv
APPARATUS REQUIRED :
Single acting cylinder
3/2 push button
3/2 pilot operated spring return dcv
Connecting tubes
AIR SUPPLY :
Shop floor air control supply with pressure regulator ,
filter, lubricators.
PROCEDURE :
Draw the circuit diagram for the indirect method of
single acting cylinder.
Connecting the cylinder ,3/2 push button , 3/2 pilot
operated spring return dcv as per the circuit diagram
Connected the air supply is given .
Operating the circuit diagram .
RESULT:
Thus a single acting cylinder is simulated in the indirect
method with help of direction control valves.
![Page 6: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/6.jpg)
5
![Page 7: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/7.jpg)
6
EX NO: 1 C DATE :
SIMULATION OF SINGLE ACTING CYLINDER
USING TWO PUSH BUTTON.
AIM :
To actuate a single acting cylinder using pilot operated 3/2 dcv and
manually actuated 3/2 dcv
APPARATUS REQUIRED :
Single acting cylinder
3/2 push button
3/2 double side pilot operated dcv
Connecting tubes
AIR SUPPLY :
Shop floor air control supply with pressure regulator ,
filter, lubricators.
PROCEDURE :
Draw the circuit diagram for the indirect method of
single acting cylinder.
Connecting the cylinder ,3/2 push button , 3/2 pilot
operated spring return dcv as per the circuit diagram
Connected the air supply is given .
Operating the circuit diagram
RESULT:
Thus a single acting cylinder is simulated in the two push
button method with help of direction control valves.
![Page 8: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/8.jpg)
7
![Page 9: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/9.jpg)
8
EX NO: 2A DATE :
SIMULATION OF DOUBLE ACTING CYLINDER
USING DIRECT METHOD
AIM :
To simulate the double acting cylinder using direct method.
APPARATUS REQUIRED :
Double acting cylinder
5/2 leaver operated dcv
Connecting tubes
PROCEDURE :
Draw the circuit diagram of the simulation of double
acting cylinder.
The components are connected the board as per the
circuit diagram.
Connected the air supply from the compressor .
They are using the air manifold to components.
The circuit is then operated to the single acting
cylinder.
And then change the difference 5/2 dcv and operated
the difference circuit
RESULT:
Thus a double acting cylinder is simulated in the direct
method with help of direction control valves.
![Page 10: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/10.jpg)
9
![Page 11: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/11.jpg)
10
EX NO: 2 B DATE :
SIMULATION OF DOUBLE ACTING CYLINDER
USING INDIRECT METHOD
AIM :
To simulate the double acting cylinder using indirect method.
APPARATUS REQUIRED :
Double acting cylinder
3/2 push button
5/2 pilot operated spring return dcv
Connecting tubes
PROCEDURE :
Draw the circuit diagram of the simulation of double
acting cylinder.
The components are connected the board as per the
circuit diagram.
Connected the air supply from the compressor .
They are using the air manifold to components.
The circuit is then operated to the single acting
cylinder.
And then change the difference 5/2 dcv and operated
the difference circuit
RESULT:
Thus a double acting cylinder is simulated in the indirect
method with help of direction control valves.
![Page 12: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/12.jpg)
11
![Page 13: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/13.jpg)
12
EX NO: 2 C DATE :
SIMULATION OF DOUBLE ACTING CYLINDER
USING TWO PUSH BUTTON
AIM :
To simulate the double acting cylinder using two push button.
APPARATUS REQUIRED :
Double acting cylinder
3/2 push button
5/2 double side pilot operated dcv
Connecting tubes
PROCEDURE :
Draw the circuit diagram of the simulation of double
acting cylinder.
The components are connected the board as per the
circuit diagram.
Connected the air supply from the compressor .
They are using the air manifold to components.
The circuit is then operated to the single acting
cylinder.
And then change the difference 5/2 dcv and operated
the difference circuit
RESULT:
Thus a double acting cylinder is simulated in the two push
button method with help of direction control valves.
![Page 14: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/14.jpg)
13
![Page 15: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/15.jpg)
14
EX NO: 3A DATE :
BASIC HYDRAULIC CIRCUITS [LINEAR MOTION]
AIM :
To working of the double acting cylinder and bi-directional motor
under hydraulics circuit
APPARATUS REQUIRED:
Double acting cylinder
4/3 leaver operated with detent control dcv
Pressure Gauge
Pressure relief valve
Filter
Connecting tubes
PROCEDURE :
The circuit diagram is drawn according to the objective
stated
The connection for pump(pressure) and tank are taken
from P and T ports on 4/3 dcv
The working ports A and B are connected to the double
acting cylinder
With use of lever, the oil is now regulated to move the
piston from forward position
Similarly when lever is moved to other side , the piston
moved to return position .
RESULT:
Thus the linear motion of cylinder is achieved by using basic
hydraulic circuits
![Page 16: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/16.jpg)
15
FILTER
TANK
PRESSURE GAUGE
PUMP
DOUBLE ACTING
CYLINDER
4/3DCV
PRESSURE RELIEF VALVE
![Page 17: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/17.jpg)
16
EX NO: 3B DATE :
BASIC HYDRAULIC CIRCUITS [ROTARY MOTION]
AIM :
To working of the double acting cylinder and bi-directional motor
under hydraulics circuit
APPARATUS REQUIRED:
Hydraulic motor
4/3 leaver operated with detent control dcv
Pressure Gauge
Pressure relief valve
Filter
Connecting tubes
PROCEDURE :
The circuit diagram is drawn according to the objective
stated
The connection for pump(pressure) and tank are taken
from P and T ports on 4/3 dcv
The working ports A and B are connected to the double
acting cylinder
With use of lever, the oil is now regulated to move the
hydraulic motor from clockwise rotary
Similarly when lever is moved to other side , the
hydraulic motor rotary the anti- clockwise .
RESULT:
Thus the linear motion of cylinder is achieved by using basic
hydraulic circuits
![Page 18: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/18.jpg)
17
![Page 19: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/19.jpg)
18
EX NO:4A DATE :
BASIC ELECTRO HYDRAULIC CIRCUITS [LINEAR
MOTION]
AIM :
To working of the double acting cylinder and bi-directional motor
under hydraulics circuit
APPARATUS REQUIRED:
double acting cylinder
4/3 double side solenoid operated dcv
Pressure Gauge
Pressure relief valve
Filter
Connecting tubes
PROCEDURE :
The circuit diagram is drawn according to the objective
stated
The connection for pump(pressure) and tank are taken
from P and T ports on 4/3 dcv
The working ports A and B are connected to the double
acting cylinder
With use of lever, the oil is now regulated to move the
hydraulic motor from clockwise rotary
Similarly when lever is moved to other side , the
hydraulic motor rotary the anti- clockwise .
RESULT:
Thus the linear motion of cylinder is achieved by using basic
hydraulic circuits
![Page 20: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/20.jpg)
19
LADDER DIAGRAM
![Page 21: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/21.jpg)
20
EX NO: 4B DATE :
BASIC ELECTRO HYDRAULIC CIRCUITS [LINEAR
MOTION]
AIM :
To working of the double acting cylinder and bi-directional motor
under hydraulics circuit
APPARATUS REQUIRED:
Hydraulic motor
4/3 double side solenoid operated dcv
Pressure Gauge
Pressure relief valve
Filter
Connecting tubes
PROCEDURE :
The circuit diagram is drawn according to the objective
stated
The connection for pump(pressure) and tank are taken
from P and T ports on 4/3 dcv
The working ports A and B are connected to the double
acting cylinder
With use of lever, the oil is now regulated to move the
hydraulic motor from clockwise rotary
Similarly when lever is moved to other side , the
hydraulic motor rotary the anti- clockwise .
RESULT:
Thus the linear motion of cylinder is achieved by using basic
hydraulic circuits
![Page 22: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/22.jpg)
21
LADDER DIAGRAM
![Page 23: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/23.jpg)
22
EX NO: 5 DATE :
STUDY AND USE OF HYDRAULIC ELEMENTS
AIM :
APPARATUS REQUIRED:
PROCEDURE :
RESULT:
![Page 24: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/24.jpg)
23
EX NO: 6 DATE :
STUDY AND USE OF PNEUMATIC ELEMENTS
AIM :
APPARATUS REQUIRED:
PROCEDURE :
RESULT:
![Page 25: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/25.jpg)
24
EX NO: 7A DATE :
SIMULATION OF PNEUMATIC LOGIC CIRCUITS
AIM :
To design a pneumatic circuit for “AND” gate logic unit using
two pressure valve for single acting cylinder.
APPARATUS REQUIRED:
AND Gate,
Double acting cylinder,
5/2 pilot operated spring return dcv
3/2 push button
PROCEDURE :
Ensure sufficient air pressure is available as input in the
FRL unit.
The connections are made as per the circuit diagram
The inlet port 1 of the 5/2 DCV (1) and 3/2 push button
(2) is connected from the FRL unit.
The outlet port 2 of the 5/2 DCV (1) and 3/2 push button
(2) is connected to the two AND Gate
AND Gate port is connected to pilot operated 5/2 DCV
5/2 DCV port is connected to blank end of double
acting cylinder.
The forward stroke occurs during the following
condition.
RESULT:
Thus the above simulation was made for the “AND” logic gate
using basic pneumatic trainer kit.
![Page 26: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/26.jpg)
25
DIAGRAM:
DOUBLE ACTING CYLINDER
5/2 DCV
3/2 PUSH BUTTON
AND GATE
![Page 27: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/27.jpg)
26
EX NO: 7B DATE :
SIMULATION OF PNEUMATIC LOGIC CIRCUITS
AIM :
To design a pneumatic circuit for “AND” gate logic unit using
two pressure valve for single acting cylinder.
APPARATUS REQUIRED:
OR Gate,
Double acting cylinder,
5/2 pilot operated spring return dcv
3/2 push button
PROCEDURE :
Ensure sufficient air pressure is available as input in the
FRL unit.
The connections are made as per the circuit diagram
The inlet port 1 of the 5/2 DCV (1) and 3/2 push button
(2) is connected from the FRL unit.
The outlet port 2 of the 5/2 DCV (1) and 3/2 push button
(2) is connected to the two OR gate
OR gate port is connected to pilot operated 5/2 DCV
5/2 DCV port is connected to blank end of double
acting cylinder.
The forward stroke occurs during the following
condition.
RESULT:
Thus the above simulation was made for the “AND” logic gate
using basic pneumatic trainer kit.
![Page 28: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/28.jpg)
27
DIAGRAM:
![Page 29: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/29.jpg)
28
EX NO: 8A DATE :
SIMULATION OF PNEUMATIC CIRCUIT FOR
METER-IN
AIM :
To simulate a pneumatic circuit for Meter-in circuit for double
acting cylinder
APPARATUS REQUIRED:
Double acting cylinder,
5/2 pilot operated spring return dcv
3/2 push button
Flow control valves
PROCEDURE:
Ensure sufficient air pressure is available as input in the
FRL unit.
The connections are made as per the circuit diagram
The inlet port 1 of the 5/2 DCV and 3/2 push button is
connected from the FRL unit.
The outlet port 2 of the 3/2 push button 5/2 DCV is
connected
Flow control valve port is connected to pilot operated
5/2 DCV
5/2 DCV port is connected to blank end of double
acting cylinder.
The forward stroke occurs during the following
condition.
RESULT:
Thus the above simulation was made for the “Flow control valves
using meter in circuit pneumatic trainer kit.
![Page 30: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/30.jpg)
29
DIAGRAM:
![Page 31: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/31.jpg)
30
EX NO: 8B DATE :
SIMULATION OF PNEUMATIC CIRCUIT FOR
METER-OUT
AIM :
To simulate a pneumatic circuit for Meter-out circuit for double
acting cylinder
APPARATUS REQUIRED:
Double acting cylinder,
5/2 pilot operated spring return dcv
3/2 push button
Flow control valves
PROCEDURE:
Ensure sufficient air pressure is available as input in the
FRL unit.
The connections are made as per the circuit diagram
The inlet port 1 of the 5/2 DCV and 3/2 push button is
connected from the FRL unit.
The outlet port 2 of the 3/2 push button 5/2 DCV is
connected
Flow control valve port is connected to pilot operated
5/2 DCV
5/2 DCV port is connected to blank end of double
acting cylinder.
The forward stroke occurs during the following
condition.
RESULT:
Thus the above simulation was made for the “Flow control valves
using meter out circuit pneumatic trainer kit.
![Page 32: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/32.jpg)
31
DIAGRAM:
![Page 33: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/33.jpg)
32
EX NO: 9 DATE :
SIMULATION OF PNEUMATIC SEQUENCING
CIRCUITS OF A+
B+ A
- B
-
AIM :
To design a pneumatic circuit for two actuators A & B to give
sequence A+
B+
A- B
-
APPARATUS REQUIRED:
Double acting cylinder,
5/2 pilot operated dcv
3/2 limit switch
FRL unit, Manifold.
PROCEDURE:
Ensure sufficient air pressure is available as input in the
FRL unit.
The connections are made as per the circuit diagram
The inlet port 1 of the 5/2 DCV and 3/2 /2 limit switch
is connected from the FRL unit.
The outlet port 2 of the 3/2 push button to 5/2 DCV pilot
is connected
5/2 DCV port is connected to blank end of double
acting cylinder.
The forward stroke occurs during the following
condition.
RESULT:
Thus the above simulation was made for the “sequence A+
B+
A- B
- using
3/2 limit switch pneumatic trainer kit.
![Page 34: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/34.jpg)
33
DIAGRAM:
![Page 35: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/35.jpg)
34
EX NO: 10 DATE:
SIMULATION OF ELECTRO PNUMATIC
SEQUENCING CIRCUITS
AIM:
To design a Electro pneumatic circuit for the sequence A+B
+A
-B
-
APPARATUS REQUIRED:
Double acting cylinders
Relay box , 3/2 push buttons
Limit switches – 4 No
5/2 double solenoid DCV-2 No
Connecting tubes & wires
AIR SUPPLY:
Shop floor air control supply with FRL
PROCEDURE:
Draw the circuit diagram for the actuation of the
sequence.
Connect the cylinder , 3/2 push button , 5/2 double
solenoid DCVs , limit switches as per the circuit
diagram
Connect the air supply to the circuit
Operate the circuit as required.
RESULT:
Thus the above Electro pneumatic sequencing simulation was made.
![Page 36: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/36.jpg)
35
Electro pneumatic circuit for the sequence A+B
+A
-B
-
LADDER DIAGRAM
![Page 37: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/37.jpg)
36
EX NO: 11 DATE:
SIMULATION OF AUTOMATION STUDIO
SOFTWARE
AIM:
To design a pneumatic circuit for sequence A+B
+ C
+A
-B
- C
-
APPARATUS REQUIRED:
Automation Studio
Hardware key
PROCEDURE:
Draw the circuit diagram for the actuation of the
sequence.
Connect the cylinder , 3/2 push button , 5/2 pilot
operated DCV ,limit switches as per the circuit diagram
Connect the air flow lines to the circuit
Simulate the circuit as required.
RESULT:
Thus the above sequencing simulation was made in the Automation Studio.
![Page 38: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/38.jpg)
37
Pneumatic circuit for sequence A+B
+ C
+A
-B
- C
-:
![Page 39: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/39.jpg)
38
EX NO: 12 DATE:
SIMULATION OF ELCTRO HYDRAULIC
SEQUENCING CIRCUITS USING MITSUBISHI PLC
AIM:
To design a pneumatic circuit for sequence A+B
+A
-B
-
APPARATUS REQUIRED:
Double acting cylinders
Electro hydraulic trainer kit
Proximity sensor– 4 No
5/2 double side Solenoid DCV-2 No
Connecting tubes, wires
PROCEDURE:
Draw the circuit diagram for the actuation of the
sequence.
Connect the cylinder , 5/2 Solenoid operated DCV ,
proximity sensor as per the circuit diagram
Connect the oil supply to the circuit
Operate the circuit as required.
RESULT:
Thus the above sequencing simulation was made.
![Page 40: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/40.jpg)
39
Electro hydraulic circuit for sequence A+B
+A
-B
-
![Page 41: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/41.jpg)
40
LADDER DIAGRAM:
![Page 42: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/42.jpg)
41
EX NO: 13 DATE:
SIMULATION OF ELECTRO PNUMATIC
SEQUENCING CIRCUITS USING OMRON PLC
AIM:
To design a Electro pneumatic circuit for the sequence A+B
+A
-B
-
APPARATUS REQUIRED:
Double acting cylinders
Relay box , 3/2 push buttons
Limit switches – 4 No
5/2 double solenoid DCV-2 No
Connecting tubes & wires
AIR SUPPLY:
Shop floor air control supply with FRL
PROCEDURE:
Draw the circuit diagram for the actuation of the
sequence.
Connect the cylinder , 3/2 push button , 5/2 double
solenoid DCVs , limit switches as per the circuit
diagram
Connect the air supply to the circuit
Operate the circuit as required.
RESULT:
Thus the above Electro pneumatic sequencing simulation was made.
![Page 43: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/43.jpg)
42
Electro pneumatic circuit for the sequence A+B
+A
-B:
-
![Page 44: INDEX []€¦ · INDEX SI.NO EXPERIMENT DETAILS PAGE 1 ... STUDY AND USE OF HYDRAULIC ELEMENTS 22 6 ... connected from the FRL unit](https://reader030.vdocuments.net/reader030/viewer/2022032611/5b5b9c827f8b9a01748e6ce7/html5/thumbnails/44.jpg)
43
LADDER DIAGRAM: