industry - igus · machining units/machine tools, storage and retrieval units for high-bay...

34
industry plastics for longer life ® ... ... www.igus.eu/offshore ... offshore chainflex ® cables with DNV-GL certification

Upload: phungquynh

Post on 15-Feb-2019

216 views

Category:

Documents


0 download

TRANSCRIPT

industryplastics for longer life®...

... www.igus.eu/offshore ...

offshorechainflex® cables with DNV-GL certification

3

348 chainflex® cables ... ... with GL-DNV approval

chai

nflex

® c

able

s

Jack

et m

ater

ial

Shi

elde

d

Min

imum

ben

ding

ra

dius

, mov

ed

[fact

or x

d]

Tem

pera

ture

, mov

ed

from

/to

[°C

]

Min

imum

ben

ding

ra

dius

, fix

ed

[fact

or x

d]

Tem

pera

ture

, fix

ed

from

/to

[°C

]

Pric

e in

dex

App

rova

ls a

nd

stan

dard

s

Flam

e-re

tard

ant

Oil-

resi

stan

t

Hal

ogen

-fre

e

UV-

resi

stan

t

Tors

ion

resi

stan

t

v m

ax. u

nsup

port

ed

[m/s

]

v m

ax. g

lidin

g

[m/s

]

a m

ax. [

m/s

2]

Num

ber o

f cor

es

Cro

ss s

ectio

n Ø

[mm

2]

Pag

e

CF77.UL.D PUR 6.8-7.5 -35/+80 4 -40/+80 ü ü ü ü ü 10 5 80 2 - 42 0.25-4.0 6

CF78.UL PUR ü 6.8-7.5 -35/+80 4 -40/+80 ü ü ü ü 10 5 80 3 - 42 0.50-4.0 10

CF9.UL TPE 5 -35/+100 3 -40/+100 ü ü ü ü 10 6 100 2 - 36 0.25-6.0 14

CF10.UL TPE 5 -35/+100 3 -40/+100 ü ü ü 10 6 100 2 - 25 0.25-0.40 18

CF240.PUR PUR ü 10-12 -20/+80 5 -40/+80 ü ü ü ü 3 2 20 3 - 18 0.14-0.34 22

CFBUS.PUR PUR ü 12.5 -20/+70 7.5 -40/+70 ü ü ü ü 3 2 30 2 - 8 0.08-0.5 26

CFBUS TPE ü 10-12.5 -35/+70 5 -40/+70 ü ü ü 10 6 100 2 - 13 0.08-1.5 30

CF111.D PUR ü 10 -20/+80 5 -40/+80 ü ü ü ü 10 5 30 6-16 0.14-1.5 36

CF113.D PUR ü 7.5 -20/+80 5 -40/+80 ü ü ü ü 5 3 50 4 - 18 0.14-1.5 42

CF27.D PUR ü 7.5 -20/+80 4 -40/+80 ü ü ü ü 10 5 80 4-8 0.75-50 50

CF34.UL.D TPE 7.5 -35/+90 4 -40/+90 ü ü ü ü 10 6 80 3 - 5 1.5-50.0 54

CF35.UL TPE ü 7.5 -35/+90 4 -40/+90 ü ü ü 10 6 80 3 - 4 0.5-50.0 58

CF300.UL.D TPE 7.5 -35/+90 4 -40/+90 ü ü ü ü 10 6 100 1 4.0-185.0 62

CFPE TPE 7.5 -35/+90 4 -40/+90 ü ü ü ü 10 6 100 1 1.5-35.0 64

CF310.UL TPE ü 7.5 -35/+90 4 -40/+90 ü ü ü 10 6 100 1 2.5-185.0 66

NEK 606 –MUD resistanceNEK 606 is an norwegian standard for all cables which are in use in offshore applications. Our PUR outer jackets of CF77.UL.D, CF78.UL, CF170.D, CF180, CF2, CF240.PUR, CF211.PUR, CF112, CF113,CF111.D, CF113.D, CFLK, CF270.UL.D and CF27.D according to the requirements of the MUD oil-test of NEK 606.

igus® GmbH Cologne | Tel. +49-2203 9649-800 Fax -222 | [email protected] | www.chainflex.eu

4 5

1,040 types from stock no cutting costs ... ... no minimum order quantity ...(up to 10 cuts of the same types) igus® GmbH Cologne | Tel. +49-2203 9649-800 Fax -222 | [email protected] | www.chainflex.eu

PUR Control cable | CF77.UL.DCF77.UL.D

PUR6.8-7.5xd

CF77.UL.DPUR

6.8-7.5xd

for high load requirements PUR outer jacket oil-resistant and coolant-resistant flame-retardant notch-resistant PVC-free/halogen-free hydrolysis-resistant and microbe-resistant

Conductor Fine-wire stranded conductor consisting of bare copper wires (following EN 60228)

Core insulation Mechanically high-quality TPE mixture.

Core stranding Number of cores <12: Cores stranded in a layer with short pitch length.Number of cores ≥ 12: Cores combined in bundles and stranded together around a centre for high tensile stresses with adapted, short pitch lengths and pitch directions, especially low-torsion structure.

Core identification Cores < 0.5 mm²: Colour code in accordance with DIN 47100Cores ≥ 0,5 mm²: Cores black with white numerals, one core green-yellowCF77.UL.03.04.INI: brown, blue, black, white

Outer jacket Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in e-chains® (following DIN VDE 0282 Part 10). Colour: Window grey (similar to RAL 7040)CF77.UL.03.04.INI: Colour: Colza yellow (similar to RAL 1021)

Bending radius moved < 10 m travel distance: min. 6.8 x d≥ 10 m travel distance: min. 7.5 x d

fixed minimum 4 x dTemperature moved -35 °C to +80 °C

fixed -40 °C to +80 °Cv max. unsupported/gliding

10 m/s, 5 m/s

a max. 80 m/s2

Travel distance Freely suspended travel distances and up to 100 m for gliding applications, Class 4

Torsion ± 180°, with 1 m cable length

UV-resistance Medium

Nominal voltage Number of cores < 12: 300/500 VNumber of cores < 12 (0.25-0.34): 300/300 VNumber of cores ≥ 12: 300/300 V (following DIN VDE 0245)

Testing voltage 2000 V (following DIN VDE 0281-2)

Oil Oil-resistant (following DIN EN 50363-10-2), Class 3

Offshore MUD-resistant following NEK 606 - status 2009

Flame-retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992)

Halogen-free Following EN 50267-2-1

UL/CSA < 0.5 mm²: Style 10493 and 20233, 300 V, 80 °C≥ 0.5 mm²: Style 11323 and 21223, 1000 V, 80 °C

NFPA Following NFPA 79-2012 chapter 12.9

CEI Following CEI 20-35

CE Following 2006/95/EC

DESINA According to VDW, DESINA standardisation

Lead free Following 2011/65/EC (RoHS-II)

Clean room According to ISO Class 1. Outer jacket material complies with CF77.UL.05.12.D, tested by IPA according to standard 14644-1

CTP Certified according to No. C-DE.PB49.B.00416

EAC Certified according to No. TC RU C-DE.ME77.B.01254

GL Certified according to GL Type Testing – Certificate No.: 61 935-14 HH

Typical application areas for high load requirements almost unlimited resticance to oil indoor and outdoor applications with average sun radiation freely suspended travel distances and up to 100 m for gliding applications Machining units/machine tools, storage and retrieval units for high-bay warehouses, packaging industry, quick handling, refrigerating sector

New! Guaranteed lifetime for this series according to the "chainflex® guarantee club" conditions Page 4-5Double strokes* 5 million 7.5 million 10 million

Temperature, from/to [°C]

Travel distance [m]

R min. [factor x d] R min. [factor x d] R min. [factor x d]

< 10 m ≥ 10 m < 10 m ≥ 10 m < 10 m ≥ 10 m

-35 / -25 8.5 10 9.5 11 10.5 12

-25 / +70 ≤ 100 6.8 7.5 7.5 8.5 8.5 9.5

+70 / +80 7.5 10 9.5 11 10.5 12

* higher number of double strokes possible

Imag

e ex

empl

ary. eplan download, configurators www.igus.eu/CF77

Class 5.4.3 5 high load requirements 4 travel distance up to 100 m 3 oil-resistant

76

CF77.UL.02.04.DCF77.UL.03.04.INICF77.UL.05.04.DCF77.UL.05.05.DCF77.UL.05.07.DCF77.UL.05.12.DCF77.UL.05.18.DCF77.UL.05.25.DCF77.UL.05.30.DCF77.UL.07.03.DCF77.UL.07.04.DCF77.UL.07.05.DCF77.UL.07.07.DCF77.UL.07.12.DCF77.UL.07.18.DCF77.UL.07.20.DCF77.UL.07.25.DCF77.UL.07.36.DCF77.UL.07.42.D 1)

CF77.UL.10.02.DCF77.UL.10.03.DCF77.UL.10.04.DCF77.UL.10.05.DCF77.UL.10.07.DCF77.UL.10.12.DCF77.UL.10.18.DCF77.UL.10.25.DCF77.UL.10.42.D

CF77.UL.15.03.DCF77.UL.15.04.DCF77.UL.15.05.DCF77.UL.15.07.D 17)

CF77.UL.15.12.DCF77.UL.15.18.DCF77.UL.15.25.DCF77.UL.15.36.D 1)

CF77.UL.15.42.D 1)

CF77.UL.25.03.DCF77.UL.25.04.DCF77.UL.25.05.DCF77.UL.25.07.D 17)

CF77.UL.40.04.D 1)

1,040 types from stock no cutting costs ... ... no minimum order quantity ...(up to 10 cuts of the same types) igus® GmbH Cologne | Tel. +49-2203 9649-800 Fax -222 | [email protected] | www.chainflex.eu

PUR Control cable | CF77.UL.DCF77.UL.D

PUR6.8-7.5xd

CF77.UL.DPUR

6.8-7.5xd

Image exemplary.

Product rangePart No.

Number of cores and conductor nominal cross section [mm2]

External diameter max. [mm]

Copper index [kg/km]

Weight [kg/km]

€/m

4 x 0.25 5.5 11 354 x 0.34 5.5 17 404 G 0.5 6.0 22 445 G 0.5 6.5 28 527 G 0.5 8.0 41 80

12 G 0.5 10.0 66 13218 G 0.5 12.0 99 18425 G 0.5 14.0 138 24730 G 0.5 15.0 165 3253 G 0.75 6.5 24 554 G 0.75 7.0 32 645 G 0.75 7.5 40 757 G 0.75 8.5 56 106

12 G 0.75 12.0 96 19218 G 0.75 13.5 143 26020 G 0.75 14.5 159 29225 G 0.75 16.0 198 36836 G 0.75 18.5 297 52442 G 0.75 21.0 365 604

2 x 1.0 6.5 22 543 G 1.0 6.5 32 654 G 1.0 7.0 43 795 G 1.0 8.0 53 977 G 1.0 9.0 74 119

12 G 1.0 12.5 127 23418 G 1.0 15.0 191 33925 G 1.0 17.0 264 45242 G 1.0 22.5 462 708

1) Delivery time upon request.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core

Product rangePart No.

Number of cores and conductor nominal cross section [mm2]

External diameter max. [mm]

Copper index [kg/km]

Weight [kg/km]

€/m

3 G 1.5 7.5 48 864 G 1.5 8.0 64 1055 G 1.5 8.5 80 1257 G 1.5 10.5 111 174

12 G 1.5 14.0 191 30818 G 1.5 17.0 286 47725 G 1.5 19.5 396 63036 G 1.5 23.5 594 89142 G 1.5 26.5 729 10403 G 2.5 8.5 80 1244 G 2.5 9.5 106 1555 G 2.5 10.5 132 1927 G 2.5 12.5 185 2704 G 4.0 11.5 185 257

1) Delivery time upon request.17) Using the cables with "7 G 1.5 mm2" and "7 G 2.5 mm2" it is essential: bending radius 17 x d with travel distance ≥ 5 m.When the travel distance is not less than 5 m, a bending radius not less than 17 x d has to be used.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core

Order example: CF77.UL.10.03.D – in your desired length (0.5 m steps)CF77.UL.D chainflex® series .10 Code nominal cross section .03 Number of cores

Online order: www.chainflex.eu/CF77

Delivery time 24h or today.Delivery time means time until shipping of goods.

eplan download, configurators www.igus.eu/CF77

Class 5.4.3 5 high load requirements 4 travel distance up to 100 m 3 oil-resistant

98

1,040 types from stock no cutting costs ... ... no minimum order quantity ...(up to 10 cuts of the same types) igus® GmbH Cologne | Tel. +49-2203 9649-800 Fax -222 | [email protected] | www.chainflex.eu

PUR Control cable | CF78.ULCF78.UL

PUR6.8-7.5xd

CF78.ULPUR

6.8-7.5xd

for high load requirements PUR outer jacket shielded oil-resistant and coolant-resistant flame-retardant notch-resistant PVC-free/halogen-free hydrolysis-resistant and microbe-resistant

Conductor Fine-wire stranded conductor consisting of bare copper wires (following EN 60228)

Core insulation Mechanically high-quality TPE mixture.

Core stranding Number of cores <12: Cores stranded in a layer with short pitch length.Number of cores ≥ 12: Cores combined in bundles and stranded together around a centre for high tensile stresses with adapted, short pitch lengths and pitch directions, especially low-torsion structure.

Core identification Cores < 0.5 mm²: Colour code in accordance with DIN 47100Cores ≥ 0.5 mm²: Cores black with white numerals, one core green-yellow

Inner jacket PUR mixture adapted to suit the requirements in e-chains®.

Overall shield Bending-resistant braiding made of tinned copper wires. Coverage approx. 55% linear, approx. 80% optical.

Outer jacket Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in e-chains® (following DIN VDE 0282 Part 10).Colour: Window grey (similar to RAL 7040)

Bending radius moved < 10 m travel distance: min. 6.8 x d≥ 10 m travel distance: min. 7.5 x d

fixed minimum 4 x dTemperature moved -35 °C to +80 °C

fixed -40 °C to +80 °Cv max. unsupported/gliding

10 m/s, 5 m/s

a max. 80 m/s2

Travel distance Freely suspended travel distances and up to 100 m for gliding applications, Class 4

UV-resistance Medium

Nominal voltage Number of cores < 12: 300/500 VNumber of cores < 12 (0.25-0.34): 300/300 VNumber of cores ≥ 12: 300/300 V (following DIN VDE 0245)

Testing voltage 2000 V (following DIN VDE 0281-2)

Oil Oil-resistant (following DIN EN 50363-10-2), Class 3

Offshore MUD-resistant following NEK 606 - status 2009

Flame-retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992)

Halogen-free Following EN 50267-2-1

UL/CSA < 0,5 mm²: Style 10493 and 20233, 300 V, 80 °C≥ 0,5 mm²: Style 11323 and 21223, 1000 V, 80 °C

NFPA Following NFPA 79-2012 chapter 12.9

CEI Following CEI 20-35

CE Following 2006/95/EC

Lead free Following 2011/65/EC (RoHS-II)

Clean room According to ISO Class 1. Outer jacket material complies with CF77.UL.05.12.D, tested by IPA according to standard 14644-1

CTP Certified according to No. C-DE.PB49.B.00416

EAC Certified according to No. TC RU C-DE.ME77.B.01254

GL Certified according to GL Type Testing – Certificate No.: 61 935-14 HH

Typical application areas for high load requirements almost unlimited resticance to oil indoor and outdoor applications with average sun radiation freely suspended travel distances and up to 100 m for gliding applications Machining units/machine tools, storage and retrieval units for high-bay warehouses, packaging industry, quick handling, refrigerating sector

New! Guaranteed lifetime for this series according to the "chainflex® guarantee club" conditions Page 4-5Double strokes* 5 million 7.5 million 10 million

Temperature, from/to [°C]

Travel distance [m]

R min. [factor x d] R min. [factor x d] R min. [factor x d]

< 10 m ≥ 10 m < 10 m ≥ 10 m < 10 m ≥ 10 m

-35 / -25 8.5 10 9.5 11 10.5 12

-25 / +70 ≤ 100 6.8 7.5 7.5 8.5 8.5 9.5

+70 / +80 7.5 10 9.5 11 10.5 12

* higher number of double strokes possible

Imag

e ex

empl

ary. eplan download, configurators www.igus.eu/CF78

Class 5.4.3 5 high load requirements 4 travel distance up to 100 m 3 oil-resistant

1110

CF78.UL.05.04CF78.UL.05.05CF78.UL.05.07CF78.UL.05.09CF78.UL.05.12CF78.UL.05.18CF78.UL.05.25CF78.UL.07.03CF78.UL.07.04CF78.UL.07.05CF78.UL.07.07CF78.UL.07.12CF78.UL.07.18CF78.UL.07.36CF78.UL.07.42 1)

CF78.UL.10.03CF78.UL.10.04CF78.UL.10.05CF78.UL.10.07CF78.UL.10.12CF78.UL.10.18 1)

CF78.UL.10.25CF78.UL.15.03CF78.UL.15.04CF78.UL.15.05CF78.UL.15.07CF78.UL.15.12CF78.UL.15.18CF78.UL.15.25CF78.UL.15.36 1)

CF78.UL.15.42 1)

CF78.UL.25.04CF78.UL.25.05CF78.UL.25.07CF78.UL.40.04 1)

1,040 types from stock no cutting costs ... ... no minimum order quantity ...(up to 10 cuts of the same types) igus® GmbH Cologne | Tel. +49-2203 9649-800 Fax -222 | [email protected] | www.chainflex.eu

PUR Control cable | CF78.ULCF78.UL

PUR6.8-7.5xd

CF78.ULPUR

6.8-7.5xd

eplan download, configurators www.igus.eu/CF78

Image exemplary.

Order example: CF78.UL.15.18 – in your desired length (0.5 m steps)CF78.UL chainflex® series .15 Code nominal cross section .18 Number of cores

Online order: www.chainflex.eu/CF78

Delivery time 24h or today.Delivery time means time until shipping of goods.

Product rangePart No.

Number of cores and conductor nominal cross section [mm2]

External diameter max. [mm]

Copper index [kg/km]

Weight [kg/km]

€/m

(4 G 0.5)C 8.0 40 79(5 G 0.5)C 8.5 48 94(7 G 0.5)C 9.5 62 123(9 G 0.5)C 11.0 81 148

(12 G 0.5)C 12.5 97 207(18 G 0.5)C 14.0 156 257(25 G 0.5)C 16.0 180 366(3 G 0.75)C 8.0 44 79(4 G 0.75)C 8.5 52 99(5 G 0.75)C 9.5 64 108(7 G 0.75)C 10.5 87 146

(12 G 0.75)C 13.5 145 252(18 G 0.75)C 16.0 207 367(36 G 0.75)C 21.5 416 728(42 G 0.75)C 23.5 489 800

(3 G 1.0)C 8.5 53 90(4 G 1.0)C 9.0 65 107(5 G 1.0)C 9.5 78 124(7 G 1.0)C 11.0 110 170

(12 G 1.0)C 14.5 178 307(18 G 1.0)C 17.0 256 424(25 G 1.0)C 19.5 347 567(3 G 1.5)C 9.5 72 133(4 G 1.5)C 10.0 90 139(5 G 1.5)C 10.5 115 166(7 G 1.5)C 12.5 153 226

(12 G 1.5)C 16.5 249 403(18 G 1.5)C 19.0 368 564(25 G 1.5)C 22.5 495 755(36 G 1.5)C 26.5 715 1147(42 G 1.5)C 29.5 884 1360(4 G 2.5)C 11.5 148 212(5 G 2.5)C 12.5 177 247(7 G 2.5)C 14.5 245 350(4 G 4.0)C 14.0 217 342

1) Delivery time upon request.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core

Class 5.4.3 5 high load requirements 4 travel distance up to 100 m 3 oil-resistant

1312

1,040 types from stock no cutting costs ... ... no minimum order quantity ...(up to 10 cuts of the same types) igus® GmbH Cologne | Tel. +49-2203 9649-800 Fax -222 | [email protected] | www.chainflex.eu

TPE Control cable | CF9.ULCF9.UL

TPE5 x d

CF9.ULTPE5 x d

for maximum load requirements TPE outer jacket oil-resistant bio-oil-resistant flame-retardant PVC-free low-temperature-flexible hydrolysis-resistant and microbe-resistant

Imag

e ex

empl

ary. eplan download, configurators www.igus.eu/CF9UL

Product improvement!

Strip cables 50% faster!

www.igus.eu/CFRIP

CFRIP-technology

®

Conductor Stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228).

Core insulation Mechanically high-quality TPE mixture.

Core stranding Number of cores <12: Cores stranded in a layer with short pitch length.Number of cores ≥ 12: Cores combined in bundles and stranded together around a centre for high tensile stresses with adapted, short pitch lengths and pitch directions, especially low-torsion structure.

Core identification Cores < 0.,75 mm2: Colour code in accordance to DIN 47100Cores ≥ 0.75 mm2: Cores black with white numerals, one core green-yellowCF9.UL.02.03.INI: brown, blue, blackCF9.UL.03.04.INI: brown, blue, black, whiteCF9.UL.03.05.INI: brown, blue, black, white, green-yellow

Outer jacket Low-adhesion mixture on the basis of TPE, especially abrasion-resistant and highly flexible, adapted to suit the requirements in e-chains®. Colour: Slate grey (similar to RAL 7015)

CFRIP Strip cables 50% faster: The tear strip is in the outer jacketVideo www.igus.eu/CFRIP

Bending radius moved minimum 5 x dfixed minimum 3 x d

Temperature moved -35 °C to +100 °Cfixed -40 °C to +100 °C

v max. unsupported/gliding

10 m/s, 6 m/s

a max. 100 m/s2

Travel distance Freely suspended travel distances and up to 400 m and more for gliding applications, Class 5

Torsion ± 90°, with 1 m cable length

UV-resistance High

Nominal voltage 300/500 V (following DIN VDE 0245)

Testing voltage 2000 V (following DIN VDE 0281-2)

Oil Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4

Flame-retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free Free from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992)

UL/CSA < 0.5 mm2: Style 10479 and 21529, 300 V, 90 °C≥ 0.5 mm2: Style 10258 and 21387, 1000 V, 90 °C (starting from manufacturing date 11/2012)

NFPA Following NFPA 79-2012 chapter 12.9

CEI Following CEI 20-35

CE Following 2006/95/EC

Lead free Following 2011/65/EC (RoHS-II)

Clean room According to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, tested by IPA according to standard 14644-1

CTP Certified according to No. C-DE.PB49.B.00416

EAC Certified according to No. TC RU C-DE.ME77.B.01254

GL Certified according to GL Type Testing – Certificate No.: 61 935-14 HH

Typical application areas for maximum load requirements almost unlimited resistance to oil, also with bio-oils indoor and outdoor applications, UV-resistant freely suspended travel distances and up to 400 m and more for gliding applications Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications

New! Guaranteed lifetime for this series according to the "chainflex® guarantee club" conditions Page 4-5Double strokes* 5 million 7.5 million 10 million

Temperature, from/to [°C]

v max. [m/s] a max. Travel distance R min. R min. R min.

unsupported gliding [m/s2] [m] [factor x d] [factor x d] [factor x d]

-35 / -25

10 6 100 > 400

6.8 7.5 10

-25 / +90 5 6 7

+90 / +100 6.8 7.5 10

* higher number of double strokes possible

Class 6.5.4 6 maximum load requirements 5 travel distance up to 400 m and more 4 oil-resistant

1514

CF9.UL.02.02CF9.UL.02.03.INICF9.UL.02.04CF9.UL.02.06CF9.UL.02.07 1)

CF9.UL.02.08CF9.UL.02.12CF9.UL.03.04.INICF9.UL.03.05.INI 1)

CF9.UL.03.06CF9.UL.03.08CF9.UL.05.02CF9.UL.05.03 1)

CF9.UL.05.04CF9.UL.05.05CF9.UL.05.07CF9.UL.05.12CF9.UL.05.18CF9.UL.05.25CF9.UL.05.36 1)

CF9.UL.07.05CF9.UL.07.07CF9.UL.07.12CF9.UL.07.20 1)

CF9.UL.07.25CF9.UL.10.03CF9.UL.10.04CF9.UL.10.05 1)

CF9.UL.10.12CF9.UL.10.18CF9.UL.10.25

CF9.UL.15.04CF9.UL.15.05CF9.UL.15.07 17)

CF9.UL.15.12CF9.UL.15.18CF9.UL.15.25CF9.UL.25.04CF9.UL.25.05CF9.UL.25.07 1) 17)

CF9.UL.25.12CF9.UL.25.16 1)

CF9.UL.25.18CF9.UL.25.25CF9.UL.40.04CF9.UL.60.04

1,040 types from stock no cutting costs ... ... no minimum order quantity ...(up to 10 cuts of the same types) igus® GmbH Cologne | Tel. +49-2203 9649-800 Fax -222 | [email protected] | www.chainflex.eu

TPE Control cable | CF9.ULCF9.UL

TPE5 x d

CF9.ULTPE5 x d

Image exemplary.

Strip cables 50 % faster!

Product rangePart No.

Number of cores and conductor nominal cross section [mm2]

External diameter max. [mm]

Copper index [kg/km]

Weight [kg/km]

€/m

2 x 0.25 5.0 6 283 x 0.25 5.5 8 324 x 0.25 5.5 11 386 x 0.25 6.5 16 497 x 0.25 7.0 19 598 x 0.25 7.5 22 64

12 x 0.25 8.5 32 944 x 0.34 6.0 15 435 x 0.34 6.5 18 536 x 0.34 6.5 22 578 x 0.34 7.5 29 762 x 0.5 6.0 11 433 x 0.5 6.5 16 524 x 0.5 7.0 22 605 x 0.5 7.5 27 707 x 0.5 8.5 37 96

12 x 0.5 11.5 64 17018 x 0.5 13.5 96 23925 x 0.5 14.5 132 29636 x 0.5 18.5 191 4605 G 0.75 8.0 40 967 G 0.75 9.5 56 133

12 G 0.75 13.0 96 23420 G 0.75 15.5 159 34925 G 0.75 16.5 198 421

3 G 1.0 7.5 32 784 G 1.0 8.0 43 975 G 1.0 9.0 53 116

12 G 1.0 14.0 127 28318 G 1.0 16.5 191 40625 G 1.0 18.5 264 541

1) Delivery time upon request.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core

Product rangePart No.

Number of cores and conductor nominal cross section [mm2]

External diameter max. [mm]

Copper index [kg/km]

Weight [kg/km]

€/m

4 G 1.5 9.0 64 1265 G 1.5 9.5 80 1507 G 1.5 11.5 111 206

12 G 1.5 16.0 191 38418 G 1.5 19.0 286 55325 G 1.5 22.0 396 7564 G 2.5 10.5 106 1945 G 2.5 11.0 132 2397 G 2.5 13.5 185 328

12 G 2.5 19.0 317 62016 G 2.5 21.5 423 81118 G 2.5 24.0 476 91725 G 2.5 27.0 660 11994 G 4.0 12.0 169 2714 G 6.0 14.0 254 380

1) Delivery time upon request.17) Using the cables with “7 G 1.5 mm2” and “7 G 2.5 mm2” it is essential: bending radius 17 x d with travel distance ≥ 5 m.When the travel distance is not less than 5 m, a bending radius not less than 17 x d has to be used.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core

eplan download, configurators www.igus.eu/CF9UL

Order example: CF9.UL.02.12 – in your desired length (0.5 m steps)CF9.UL chainflex® series .02 Code nominal cross section .12 Number of cores

Online order: www.chainflex.eu/CF9UL

Delivery time 24h or today.Delivery time means time until shipping of goods.

igus® chainflex® cables in a rafting channel application.

Class 6.5.4 6 maximum load requirements 5 travel distance up to 400 m and more 4 oil-resistant

1716

1,040 types from stock no cutting costs ... ... no minimum order quantity ...(up to 10 cuts of the same types) igus® GmbH Cologne | Tel. +49-2203 9649-800 Fax -222 | [email protected] | www.chainflex.eu

TPE Control cable | CF10.ULCF10.UL

TPE5 x d

CF10.ULTPE5 x d

for maximum load requirements TPE outer jacket shielded oil-resistant, bio-oil-resistant flame-retardant PVC-free low-temperature-flexible hydrolysis-resistant and microbe-resistant

Imag

e ex

empl

ary. eplan download, configurators www.igus.eu/CF10UL

Product improvement!

Strip cables 50% faster!

www.igus.eu/CFRIP

CFRIP-technology

®

Conductor Stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228).

Core insulation Mechanically high-quality TPE mixture.

Core stranding Number of cores <12: Cores stranded in a layer with short pitch length.Number of cores ≥ 12: Cores combined in bundles and stranded together around a centre for high tensile stresses with adapted, short pitch lengths and pitch directions, especially low-torsion structure.

Core identification Cores < 0.75 mm2: Colour code in accordance with DIN 47100Cores ≥ 0.75 mm2: Cores black with white numerals, one core green-yellow

Inner jacket TPE mixture adapted to suit the requirements in e-chains®.

Overall shield Extremely bending-resistant braiding made of tinned copper wires.Coverage approx. 70% linear, approx. 90% optical.

Outer jacket Low-adhesion mixture on the basis of TPE, especially abrasion-resistant and highly flexible, adapted to suit the requirements in e-chains®. Colour: Slate grey (similar to RAL 7015).

CFRIP Strip cables 50% faster: The tear strip is in the inner jacketVideo www.igus.eu/CFRIP

Bending radius moved minimum 5 x dfixed minimum 3 x d

Temperature moved -35 °C to +100 °Cfixed -40 °C to +100 °C

v max. unsupported/gliding

10 m/s, 6 m/s

a max. 100 m/s2

Travel distance Freely suspended travel distances and up to 400 m and more for gliding applications, Class 5

UV-resistance High

Nominal voltage 300/500 V (following DIN VDE 0245)

Testing voltage 2000 V (following DIN VDE 0281-2)

Oil Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4

Flame-retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992)

UL/CSA < 0.5 mm2: Style 10479 and 21529, 300 V, 90 °C≥ 0.5 mm2: Style 10258 and 21387, 1000 V, 90 °C (starting from manufacturing date 11/2012)

NFPA Following NFPA 79-2012 chapter 12.9

CEI Following CEI 20-35

CE Following 2006/95/EC

Lead free Following 2011/65/EC (RoHS-II)

Clean room According to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, tested by IPA according to standard 14644-1

CTP Certified according to No. C-DE.PB49.B.00416

EAC Certified according to No. TC RU C-DE.ME77.B.01254

GL Certified according to GL Type Testing – Certificate No.: 61 935-14 HH

Typical application areas for maximum load requirements almost unlimited resistance to oil, also with bio-oils indoor and outdoor applications, UV-resistant freely suspended travel distances and up to 400 m and more for gliding applications Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications

New! Guaranteed lifetime for this series according to the “chainflex® guarantee club” conditions Page 4-5Double strokes* 5 million 7.5 million 10 million

Temperature, from/to [°C]

v max. [m/s] a max. Travel distance R min. R min. R min.

unsupported gliding [m/s2] [m] [factor x d] [factor x d] [factor x d]

-35 / -25

10 6 100 > 400

6.8 7.5 8.5

-25 / +90 5 6 7

+90 / +100 6.8 7.5 8.5

* higher number of double strokes possible

Class 6.5.4 6 maximum load requirements 5 travel distance up to 400 m and more 4 oil-resistant

1918

CF10.UL.02.04CF10.UL.02.08CF10.UL.02.12CF10.UL.02.24CF10.UL.05.04CF10.UL.05.05 1)

CF10.UL.05.12CF10.UL.05.18 1)

CF10.UL.05.25CF10.UL.07.03CF10.UL.07.04CF10.UL.07.05CF10.UL.07.07CF10.UL.07.12CF10.UL.07.20 1)

CF10.UL.07.25CF10.UL.10.02 1)

CF10.UL.10.03 1)

CF10.UL.10.04CF10.UL.10.05 1)

CF10.UL.10.07CF10.UL.10.12CF10.UL.10.18 1)

CF10.UL.10.25CF10.UL.15.04CF10.UL.15.05CF10.UL.15.07CF10.UL.15.12CF10.UL.15.18CF10.UL.25.04CF10.UL.25.07CF10.UL.25.12CF10.UL.40.04

1,040 types from stock no cutting costs ... ... no minimum order quantity ...(up to 10 cuts of the same types) igus® GmbH Cologne | Tel. +49-2203 9649-800 Fax -222 | [email protected] | www.chainflex.eu

TPE Control cable | CF10.ULCF10.UL

TPE5 x d

CF10.ULTPE5 x d

eplan download, configurators www.igus.eu/CF10UL

Image exemplary.

Strip cables 50 % faster!

Product rangePart No.

Number of cores and conductor nominal cross section [mm2]

External diameter max. [mm]

Copper index [kg/km]

Weight [kg/km]

€/m

(4 x 0.25)C 7.0 28 69(8 x 0.25)C 9.0 41 104

(12 x 0.25)C 10.5 70 158(24 x 0.25)C 13.0 120 255

(4 x 0.5)C 8.5 41 99(5 x 0.5)C 9.0 48 112

(12 x 0.5)C 13.0 117 259(18 x 0.5)C 15.0 161 349(25 x 0.5)C 16.5 204 420(3 G 0.75)C 8.5 44 106(4 G 0.75)C 9.0 54 123(5 G 0.75)C 10.0 75 156(7 G 0.75)C 11.0 99 203

(12 G 0.75)C 14.5 158 342(20 G 0.75)C 17.0 235 482(25 G 0.75)C 19.0 307 617

(2 x 1.0)C 8.5 42 105(3 G 1.0)C 9.0 53 121(4 G 1.0)C 10.0 79 158(5 G 1.0)C 10.5 92 181(7 G 1.0)C 12.0 120 238

(12 G 1.0)C 15.0 189 380(18 G 1.0)C 19.0 302 586(25 G 1.0)C 21.5 390 772(4 G 1.5)C 10.5 104 194(5 G 1.5)C 11.5 124 228(7 G 1.5)C 13.0 164 299

(12 G 1.5)C 18.0 268 523(18 G 1.5)C 21.5 413 771(4 G 2.5)C 12.0 154 276(7 G 2.5)C 15.0 250 441

(12 G 2.5)C 21.5 445 845(4 G 4.0)C 13.5 227 376

1) Delivery time upon request.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core

Order example: CF10.UL.10.02 – in your desired length (0.5 m steps)CF10.UL chainflex® series .10 Code nominal cross section .02 Number of cores

Online order: www.chainflex.eu/CF10UL

Delivery time 24h or today.Delivery time means time until shipping of goods.

The special cable structure of chainflex® CF10.UL guarantees quality – also in the igus® harnessing.

Class 6.5.4 6 maximum load requirements 5 travel distance up to 400 m and more 4 oil-resistant

Braiding in bundles

Center element for high tensile stresses

Gusset-filling extruded innen jacket

Pressure extruded outer jacket

Total shield with optimized braiding angle

2120

1,040 types from stock no cutting costs ... ... no minimum order quantity ...(up to 10 cuts of the same types) igus® GmbH Cologne | Tel. +49-2203 9649-800 Fax -222 | [email protected] | www.chainflex.eu

Typical application areas for medium load requirements almost unlimited resticance to oil indoor and outdoor applications with average sun radiation freely suspended travel distances and up to 50 m for gliding applications Machining units/machine tools, storage and retrieval units for high-bay warehouses, packaging industry, quick handling, refrigerating sector

eplan download, configurators www.igus.eu/CF240PUR

Imag

e ex

empl

ary.

PUR Data cable | CF240.PUR

Conductor Very finely stranded special cores of particularly high-flex design made of bare copper wires.

Core insulation Mechanically high-quality TPE mixture.

Core stranding The individual cores are stranded in layers with short pitch lengths.

Core identification Colour code in accordance with DIN 47100

Intermediate layer Foil taping over the external layer.

Overall shield Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical.

Outer jacket Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in e-chains® (following DIN VDE 0282 Part 10). Colour: Silver grey (similar to RAL 7001)

Bending radius moved < 10 m travel distance: min. 10 x d≥ 10 m travel distance: min. 12 x d

fixed minimum 5 x dTemperature moved -20 °C to +80 °C

fixed -40 °C to +80 °Cv max. unsupported/gliding

3 m/s, 2 m/s

a max. 20 m/s2

Travel distance Freely suspended travel distances and up to 50 m for gliding applications, Class 3

UV-resistance Medium

Nominal voltage 300/300 V (following DIN VDE 0245)

Testing voltage 1500 V

Oil Oil-resistant (following DIN EN 50363-10-2), Class 3

Offshore MUD-resistant following NEK 606 - status 2009

Flame-retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

for medium load requirements PUR outer jacket shielded oil-resistant and coolant-resistant notch-resistant PVC-free/halogen-free flame-retardant hydrolysis-resistant and microbe-resistant

Silicon-free Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992)

Halogen-free Following EN 50267-2-1

UL/CSA Style 10493 and 20233, 300 V, 80°C

NFPA Following NFPA 79-2012 chapter 12.9

CEI Following CEI 20-35

CE Following 2006/95/EC

Lead free Following 2011/65/EC (RoHS-II)

Clean room According to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D, tested by IPA according to standard 14644-1.

CTP Certified according to No. C-DE.PB49.B.00416

EAC Certified according to No. TC RU C-DE.ME77.B.01254

GL Certified according to GL Type Testing – Certificate No.: 61 936-14 HH

New! Guaranteed lifetime for this series according to the "chainflex® guarantee club" conditions Page 4-5Double strokes* 5 million 7.5 million 10 million

Temperature, from/to [°C]

Travel distance [m]

R min. [factor x d] R min. [factor x d] R min. [factor x d]

< 10 m ≥ 10 m < 10 m ≥ 10 m < 10 m ≥ 10 m

-20 / -10 12.5 15 13.5 16 14.5 17

-10 / +70 ≤ 50 10 12.5 11 13.5 12 14.5

+70 / +80 12.5 15 13.5 16 14.5 17

* higher number of double strokes possible

CF240.PURPUR

10-12 x d

CF240.PURPUR

10-12 x d Class 4.3.3 4 medium load requirements 3 travel distance up to 50 m 3 oil-resistant

2322

CF240.PUR.01.03 1)

CF240.PUR.01.04CF240.PUR.01.05 1)

CF240.PUR.01.07 1)

CF240.PUR.01.14CF240.PUR.01.18CF240.PUR.02.03CF240.PUR.02.04CF240.PUR.02.05CF240.PUR.02.07CF240.PUR.02.08CF240.PUR.02.14CF240.PUR.02.18CF240.PUR.03.03 1)

CF240.PUR.03.04CF240.PUR.03.05 1)

CF240.PUR.03.07CF240.PUR.03.14CF240.PUR.03.18

1,040 types from stock no cutting costs ... ... no minimum order quantity ...(up to 10 cuts of the same types) igus® GmbH Cologne | Tel. +49-2203 9649-800 Fax -222 | [email protected] | www.chainflex.eu

Image exemplary.

PUR Data cable | CF240.PUR

Product rangePart No.

Number of cores and conductor nominal cross section [mm2]

External diameter max. [mm]

Copper index [kg/km]

Weight [kg/km]

€/m

(3 x 0.14)C 5.5 14 37(4 x 0.14)C 6.0 16 40(5 x 0.14)C 6.0 18 45(7 x 0.14)C 6.5 24 55

(14 x 0.14)C 8.0 42 81(18 x 0.14)C 8.5 54 97(3 x 0.25)C 6.0 18 42(4 x 0.25)C 6.0 22 46(5 x 0.25)C 6.0 26 52(7 x 0.25)C 7.0 33 66(8 x 0.25)C 7.5 37 73

(14 x 0.25)C 8.5 63 106(18 x 0.25)C 9.0 75 126(3 x 0.34)C 6.0 27 49(4 x 0.34)C 6.5 31 55(5 x 0.34)C 7.0 36 62(7 x 0.34)C 8.0 48 87

(14 x 0.34)C 9.5 79 131(18 x 0.34)C 10.5 97 161

1) Delivery time upon request.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core

Order example: CF240.PUR.02.03 – in your desired length (0.5 m steps)CF240.PUR chainflex® series .02 Code nominal cross section .03 Number of cores

Online order www.igus.eu/CF240PUR

Delivery time 24h or today.Delivery time means time until shipping of goods.

eplan download, configurators www.igus.eu/CF240PUR

CF240.PURPUR

10-12 x d

CF240.PURPUR

10-12 x d Class 4.3.3 4 medium load requirements 3 travel distance up to 50 m 3 oil-resistant

2524

1,040 types from stock no cutting costs ... ... no minimum order quantity ...(up to 10 cuts of the same types) igus® GmbH Cologne | Tel. +49-2203 9649-800 Fax -222 | [email protected] | www.chainflex.eu

PUR Bus cable | CFBUS.PURCFBUS.PUR

PUR 12.5 x d

CFBUS.PUR PUR

12.5 x d

Conductor Stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228).

Core insulation According to bus specification

Core stranding According to bus specification

Core identification According to bus specificationSchedule Delivery Program

Overall shield Bending-resistant braiding made of tinned copper wires. Coverage approx. 55% linear, approx. 80% optical.

Outer jacket Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in e-chains® (following DIN VDE 0282 Part 10). Colour: Red lilac (similar to RAL 4001)

Bending radius moved minimum 12.5 x dfixed minimum 7.5 x d

Temperature moved -20 °C to +70 °Cfixed -40 °C to +70 °C

v max. unsupported/gliding

3 m/s, 2 m/s

a max. 30 m/s2

Travel distance Freely suspended travel distances and up to 20 m for gliding applications, Class 2

UV-resistance Medium

Nominal voltage 50 V

Testing voltage 500 V

Oil Oil-resistant (following DIN EN 50363-10-2), Class 3

Offshore MUD-resistant following NEK 606 - status 2009

Flame-retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992)

Imag

e ex

empl

ary.

for medium load requirements PUR outer jacket shielded oil-resistant and coolant-resistant notch-resistant PVC-free/halogen-free flame-retardant hydrolysis-resistant and microbe-resistant

Typical application areas for medium load requirements almost unlimited resticance to oil indoor and outdoor applications without direct sun radiation freely suspended travel distances and up to 20 m for gliding applications Bus connection cable for machining units/machine tools, low-temperature applications

Halogen-free Following EN 50267-2-1

UL/CSA Style 1598 and 20236, 30 V, 80 °C

NFPA Following NFPA 79-2012 chapter 12.9

CEI Following CEI 20-35

CE Following 2006/95/EC

DESINA According to VDW, DESINA standardisation

Lead free Following 2011/65/EC (RoHS-II)

Clean room According to ISO Class 1. Outer jacket material complies with CF77.UL.05.12.D, tested by IPA according to standard 14644-1

CTP Certified according to No. C-DE.PB49.B.00416

EAC Certified according to No. TC RU C-DE.ME77.B.01218

GL Certified according to GL Type Testing – Certificate No.: 61 937-14 HH

eplan download, configurators www.igus.eu/CFBUSPUR

New! Guaranteed lifetime for this series according to the "chainflex® guarantee club" conditions Page 4-5Double strokes* 5 million 7.5 million 10 million

Temperature, from/to [°C]

v max. [m/s] a max. Travel distance R min. R min. R min.

unsupported gliding [m/s2] [m] [factor x d] [factor x d] [factor x d]

-20 / -10

3 2 30 ≤ 20

15 16 17

-10 / +60 12.5 13.5 14.5

+60 / +70 15 16 17

* higher number of double strokes possible

Class 4.2.3 4 medium load requirements 2 travel distance up to 20 m 3 oil-resistant

272626

CFBUS.PUR.001 CFBUS.PUR.001

CFBUS.PUR.021 CFBUS.PUR.021CFBUS.PUR.022 2) CFBUS.PUR.022 2)

CFBUS.PUR.040 2) CFBUS.PUR.040 2)

CFBUS.PUR.045 CFBUS.PUR.045

CFBUS.PUR.050 CFBUS.PUR.050

CFBUS.PUR.056 CFBUS.PUR.056

CFBUS.PUR.060 2/16) CFBUS.PUR.060 2/16)

CFBUS.PUR.068 CFBUS.PUR.068

1,040 types from stock no cutting costs ... ... no minimum order quantity ...(up to 10 cuts of the same types) igus® GmbH Cologne | Tel. +49-2203 9649-800 Fax -222 | [email protected] | www.chainflex.eu

Image exemplary.

Order example: CFBUS.PUR.001 – in your desired length (0.5 m steps)CFBUS.PUR chainflex® series .001 Code Bus-type

Online order www.igus.eu/CFBUSPUR

Delivery time 24h or today.Delivery time means time until shipping of goods.

eplan download, configurators www.igus.eu/CFBUSPUR

Product rangePart No.

Number of cores and conductor nominal cross section [mm2]

External diameter max. [mm]

Copper index [kg/km]

Weight [kg/km]

€/m Part No. Characteristic wave impedance approx. [Ω]

Core group Colour code

Profibus Profibus(2x0.25)C 8.5 27 74 150 (2x0.25)C red, green

CAN-Bus CAN-Bus(2x0.5)C 8.5 33 83 120 (2x0.5)C white, brown(4x0.5)C 8.5 46 93 120 (4x0.5)C white, green, brown, yellow (star quad stranding)

Ethernet/CAT5/GigE Ethernet/CAT5/GigE(4x0.25)C 6.5 30 68 100 (4x0.25)C white, green, brown, yellow (star quad stranding)

(4x(2x0.15))C 7.5 35 68 100 (4x(2x0.15))C white-blue/blue, white-orange/orange, white-green/green, white-brown/brown

Ethernet/CAT6A Ethernet/CAT6A

4x(2x0.20)C 9.5 69 122 100 4x(2x0.20)C white/blue, white/orange, white/green, white/brownFireWire IEEE 1394b FireWire IEEE 1394b

(2x(2x0.15)C+2x0.38)C 9.0 62 94 100 (2x(2x0.15)C orange/blue, blue/red2x0.38 black, white

Profinet Profinet(4x0.38)C 7.0 35 66 100 (4x0.38)C white, orange, blue, yellow (star quad stranding)

USB 3.0 USB 3.0(2x(2xAWG28)+2x(2xAWG28)C)C 7.0 41 64 90 2x(2xAWG28) red/black, green/white-green

2x(2xAWG28)C blue/yellow, red/violet16) Colour outer jacket: yellow-green (similar RAL 6018 )The chainflex® types marked with 2) are cables designed as a star-quad.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core

PUR Bus cable | CFBUS.PURCFBUS.PUR

PUR 12.5 x d

CFBUS.PUR PUR

12.5 x d Class 4.2.3 4 medium load requirements 2 travel distance up to 20 m 3 oil-resistant

2928

Part No. CFBUS.001-.045

Part No. CFBUS.050-.070

1,040 types from stock no cutting costs ... ... no minimum order quantity ...(up to 10 cuts of the same types) igus® GmbH Cologne | Tel. +49-2203 9649-800 Fax -222 | [email protected] | www.chainflex.eu

TPE Bus cable | CFBUSCFBUS

TPE 10-12.5 x d

CFBUS TPE

10-12.5 x d

Conductor Stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228).

Core insulation According to bus specification

Core stranding According to bus specification

Core identification According to bus specificationSchedule Delivery Program

Inner jacket TPE mixture adapted to suit the requirements in e-chains®.

Overall shield Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical.

Outer jacket Low-adhesion mixture on the basis of TPE, especially abrasion-resistant and highly flexible, adapted to suit the requirements in e-chains®. Colour: red lilac (similar to RAL 4001)

Bending radius moved minimum 10-12.5 x dfixed minimum 5 x d

Temperature moved -35 °C to +70 °Cfixed -40 °C to +70 °C

v max. unsupported/gliding

10 m/s, 6 m/s

a max. 100 m/s2

Travel distance Freely suspended travel distances and up to 400 m for gliding applications, Class 5

UV-resistance Medium

Nominal voltage 50 V

Testing voltage 500 V

Oil Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4

Flame-retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992)

Imag

e ex

empl

ary.

for maximum load requirements TPE outer jacket shielded oil-resistant bio-oil-resistant flame-retardant hydrolysis-resistant and microbe-resistant

Typical application areas for maximum load requirements almost unlimited resistance to oil, also with bio-oils indoor and outdoor applications without direct sun radiation freely suspended travel distances and up to 400 m for gliding applications Bus connection cable for storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, indoor cranes, low-temperature applications

UL/CSA Schedule Delivery Program

NFPA Following NFPA 79-2012 chapter 12.9

CEI Following CEI 20-35

CE Following 2006/95/EC

DESINA According to VDW, DESINA standardisation

Lead free Following 2011/65/EC (RoHS-II)

Clean room According to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, tested by IPA according to standard 14644-1

CTP Certified according to No. C-DE.PB49.B.00416

EAC Certified according to No. TC RU C-DE.ME77.B.01218

GL Certified according to GL Type Testing – Certificate No.: 61 937-14 HH

eplan download, configurators www.igus.eu/CFBUS

New! Guaranteed lifetime for this series according to the "chainflex® guarantee club" conditions Page 4-5Double strokes* 5 million 7.5 million 10 million

Temperature, from/to [°C]

v max. [m/s] a max. Travel distance R min. R min. R min.

unsupported gliding [m/s2] [m] [factor x d] [factor x d] [factor x d]

-35 / -25

10 6 100 ≤ 400

12.5 13.5 14.5

-25 / +60 10 11 12

+60 / +70 12.5 13.5 14.5

-35 / -25

10 6 100 ≤ 400

15 16 17

-25 / +60 12.5 13.5 14.5

+60 / +70 15 16 17

* higher number of double strokes possible

Test data page 40

Class 6.5.4 6 maximum load requirements 5 travel distance up to 400 m 4 oil-resistant

313030

CFBUS.001 CFBUS.001CFBUS.002 CFBUS.002

CFBUS.003 CFBUS.003

CFBUS.010 CFBUS.010CFBUS.011 CFBUS.011

CFBUS.020 2) CFBUS.020 2)

CFBUS.021 CFBUS.021CFBUS.022 2) CFBUS.022 2)

CFBUS.030 4) Drop CFBUS.030 4) Drop

CFBUS.031 Trunk CFBUS.031 Trunk

CFBUS.035 CFBUS.035

CFBUS.040 2) CFBUS.040 2)

CFBUS.041 CFBUS.041CFBUS.044 CFBUS.044CFBUS.045 CFBUS.045

CFBUS.050 CFBUS.050

1,040 types from stock no cutting costs ... ... no minimum order quantity ...(up to 10 cuts of the same types) igus® GmbH Cologne | Tel. +49-2203 9649-800 Fax -222 | [email protected] | www.chainflex.eu

Image exemplary.

eplan download, configurators www.igus.eu/CFBUS

Product rangePart No.

Number of cores and conductor nominal cross section [mm2]

External diameter max. [mm]

Copper index [kg/km]

Weight [kg/km]

€/m Part No. Characteristic wave impedance approx. [Ω]

Core group Colour code

Profibus (minimum bending radius 10 x d) Style 1589/21371, 30 V, 80°C Profibus(2x0.25)C 8.5 34 83 150 (2x0.25)C red, green

(2x0.25)C+4x1.5 12.5 99 203 150 (2x0.25)C red/green4x1.5 black with white numerals 1-4

(2x0.25)C+3G0.75 11.0 58 141 150 (2x0.25)C red/green3G0.75 black, blue, green-yellow

Interbus (minimum bending radius 10 x d) Style 1589/21371, 30 V, 80°C Interbus(3x(2x0.25))C 9.0 50 90 100 3x(2x0.25) white/brown, green/yellow, grey/pink

(3x(2x0.25)+(3G1.0))C 10.5 88 142 100 3x(2x0.25) white/brown, green/yellow, grey/pink3G1.0 red, blue, green-yellow

CAN-BUS/Fieldbus (minimum bending radius 10 x d) Style 1589/21371, 30 V, 80°C CAN-BUS/Fieldbus(4x0.25)C 6.5 40 77 120 (4x0.25)C white, green, brown, yellow (star quad stranding)(2x0.5)C 8.0 41 88 120 (2x0.5)C white, brown(4x0.5)C 8.0 46 90 120 (4x0.5)C white, green, brown, yellow (star quad stranding)

DeviceNet (minimum bending radius 10 x d) Style 1589/21371, 30 V, 80°C DeviceNet((2xAWG24)C+2xAWG22)C 7.0 36 65 120 (2xAWG24)C white/blue

2xAWG22 red, black((2xAWG18)C+2xAWG15)C 11.5 110 200 120 (2xAWG18)C white/blue

2xAWG15 red, blackCC-Link (minimum bending radius 10 x d) Style 1589/21371, 30 V, 80°C CC-Link

(3xAWG20)C 8.5 46 94 110 (3xAWG20)C white, blue, yellowEthernet/CAT5/GigE (minimum bending radius 10 x d) Style 10138/21235, 300 V, 80 °C – starting from manufacturing date 4/2012 Ethernet/CAT5/GigE

(4x0.25)C 7.0 35 66 100 (4x0.25)C white, green, brown, yellow (star quad stranding)(4x(2x0.25))C 10.0 52 113 100 (4x(2x0.25))C white/brown, green/yellow, grey/pink, blue/red(4x(2x0.15))C 8.5 44 88 100 (4x(2x0.15))C white/brown, green/yellow, grey/pink, blue/red(4x(2x0.15))C 8.5 44 88 100 (4x(2x0.15))C white-blue/blue, white-orange/orange, white-green/green,

white-brown/brown

Ethernet/CAT6A (minimum bending radius 12,5 x d) Style 1589/21371, 30 V, 80°C Ethernet/CAT6A

(4x(2x0.15)C)C 10.5 76 139 100 (4x(2x0.15)C)C white/blue, white/orange, white/green, white/brown

4) manufactured without inner jacketThe chainflex® types marked with 2) are cables designed as a star-quad.Other types available on request.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core

TPE Bus cable | CFBUSCFBUS

TPE 10-12.5 x d

CFBUS TPE

10-12.5 x d

Other types page 94

Technical noteThe USB, FireWire and GigE-cables shown on these pages were developed for the ambitious industrial usage in e-chains®. High proofness to oil and lubricants is as secured as protection against electromagnetical interferences. This high mechanical service life was reached with the usage of high quality materials which even care for the electrical safeness. In single cases communication errors can occur, if very different hardware and software is combined. We recommend tests with all components and the cables before starting serial production, to get the proove for a perfect running system. Of course we support you with the details of these electrical tests. Just give us a call!

Class 6.5.4 6 maximum load requirements 5 travel distance up to 400 m 4 oil-resistant

3332

CFBUS.055 CFBUS.055

CFBUS.060 2/16) CFBUS.060 2/16)

CFBUS.065 CFBUS.065

CFBUS.066 CFBUS.066

CFBUS.070 CFBUS.070

1,040 types from stock no cutting costs ... ... no minimum order quantity ...(up to 10 cuts of the same types) igus® GmbH Cologne | Tel. +49-2203 9649-800 Fax -222 | [email protected] | www.chainflex.eu

Image exemplary.

eplan download, configurators www.igus.eu/CFBUS

Product rangePart No.

Number of cores and conductor nominal cross section [mm2]

External diameter max. [mm]

Copper index [kg/km]

Weight [kg/km]

€/m Part No. Characteristic wave impedance approx. [Ω]

Core group

Colour code

FireWire IEEE 1394a (minimum bending radius 12.5 x d) Style 1589/21371, 30 V, 80 °C FireWire IEEE 1394b2x(2x0.15)C+2x(0.34)C 8.0 41 84 100 2x(2x0.15)C orange/blue, green/red

2x(0.34)C white, blackProfinet (minimum bending radius 12.5 x d) Style 10138/21235, 300 V, 80 °C – starting from manufacturing date 4/2012 Profinet

(4x0.38)C 7.5 41 75 100 (4x0.38)C white, orange, blue, yellow (star quad stranding)USB (minimum bending radius 12.5 x d) Style 1589/21371, 30 V, 80 °C USB

((2xAWG28)+2xAWG20)C 5.5 29 48 90 (2xAWG28) white/green2xAWG20 red, black

((2xAWG24)+2xAWG20)C 6.5 33 56 90 (2xAWG24) white/green2xAWG20 red, black

DVI (minimum bending radius 12.5 x d) Style 1589/21371, 30 V, 80 °C DVI(4x(2xAWG28)C+(2xAWG28)+3xAWG28)C 9.0 37 94 100 4x(2xAWG28)C 4 x white/yellow with element-shield in blue, black, white, red

(2xAWG28) white/brown3xAWG28 green, yellow, grey

The chainflex® types marked with 2) are cables designed as a star-quad.16) Colour outer jacket: yellow-green (similar RAL 6018 )Other types available on request.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core

TPE Bus cable | CFBUSCFBUS

TPE 10-12.5 x d

CFBUS TPE

10-12.5 x d

Technical noteThe USB, FireWire and GigE-cables shown on these pages were developed for the ambitious industrial usage in e-chains®. High proofness to oil and lubricants is as secured as protection against electromagnetical interferences. This high mechanical service life was reached with the usage of high quality materials which even care for the electrical safeness. In single cases communication errors can occur, if very different hardware and software is combined. We recommend tests with all components and the cables before starting serial production, to get the proove for a perfect running system. Of course we support you with the details of these electrical tests. Just give us a call!

Order example: CFBUS.060 – in your desired length (0.5 m steps)CFBUS chainflex® series .060 Code Bus-type

Online order www.igus.eu/CFBUS

Delivery time 24h or today.Delivery time means time until shipping of goods.

Class 6.5.4 6 maximum load requirements 5 travel distance up to 400 m 4 oil-resistant

Other types page 92

3534

1,040 types from stock no cutting costs ... ... no minimum order quantity ...(up to 10 cuts of the same types) igus® GmbH Cologne | Tel. +49-2203 9649-800 Fax -222 | [email protected] | www.chainflex.eu

PUR Measuring system cable | CF111.DCF111.D

PUR 10 x d

CF111.D PUR

10 x d

Conductor Very finely stranded special cores of particularly high-flex design made of tinned copper wires.

Core insulation Mechanically high-quality TPE mixture.

Core stranding According to measuring system specification.

Core identification According to measuring system specificationSchedule Delivery Program

Element shield Extremely bending-resistant, tinned copper cover. Coverage approx. 90% optical.

Intermediate layer Foil taping over the external layer.

Overall shield Bending-resistant braiding made of tinned copper wires. Coverage approx. 55% linear, approx. 80% optical.

Outer jacket Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in e-chains® (following DIN VDE 0282 Part 10) – starting from manufacturing date 5/2012.Colour: yellow-green (similar to RAL 6018)

Bending radius moved minimum 10 x dfixed minimum 5 x d

Temperature moved -20 °C to +80 °Cfixed -40 °C to +80 °C

v max. unsupported/gliding

5 m/s, 3 m/s

a max. 30 m/s2

Travel distance Freely suspended travel distances and up to 10 m for gliding applications, Class 2

UV-resistance Medium

Nominal voltage 50 V

Testing voltage 500 V

Oil Oil-resistant (following DIN EN 50363-10-2), Class 3

Offshore MUD-resistant following NEK 606 - status 2009

Imag

e ex

empl

ary.

for medium load requirements PUR outer jacket shielded oil-resistant and coolant-resistant notch-resistant flame-retardant hydrolysis-resistant and microbe-resistant PVC-free/halogen-free

Typical application areas for medium load requirements almost unlimited resticance to oil indoor and outdoor applications without direct sun radiation freely suspended travel distances and up to 10 m for gliding applications Machining units/machine tools, low temperature applications

Flame-retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Halogen-free Following EN 50267-2-1

Silicon-free Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992)

UL/CSA Style 1589 and 20236, 30 V, 80 °C

NFPA Following NFPA 79-2012 chapter 12.9

CEI Following CEI 20-35

CE Following 2006/95/EC

DESINA According to VDW, DESINA standardisation

Lead free Following 2011/65/EC (RoHS-II)

Clean room According to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D, tested by IPA according to standard 14644-1.

CTP Certified according to No. C-DE.PB49.B.00416

GL Certified according to GL Type Testing – Certificate No.: 61 936-14 HH

eplan download, configurators www.igus.eu/CF111D

New! Guaranteed lifetime for this series according to the "chainflex® guarantee club" conditions Page 4-5Double strokes* 5 million 7.5 million 10 million

Temperature, from/to [°C]

v max. [m/s] a max. Travel distance R min. R min. R min.

unsupported gliding [m/s2] [m] [factor x d] [factor x d] [factor x d]

-20 / -10

5 3 30 ≤ 10

12.5 13.5 14.5

-10 / +70 10 11 12

+70 / +80 12.5 13.5 14.5

* higher number of double strokes possible

Bending radius is reduced by 20%!

Class 4.2.3 4 medium load requirements 2 travel distance up to 10 m 3 oil-resistant

3736

CF111.001.D CF111.001.D

CF111.002.D CF111.002.D

CF111.004.D CF111.004.D

CF111.006.D CF111.006.D

CF111.009.D CF111.009.D

CF111.010.D CF111.010.D

CF111.011.D CF111.011.D

CF111.014.D CF111.014.D

CF111.015.D CF111.015.D

CF111.020.D CF111.020.D

1,040 types from stock no cutting costs ... ... no minimum order quantity ...(up to 10 cuts of the same types) igus® GmbH Cologne | Tel. +49-2203 9649-800 Fax -222 | [email protected] | www.chainflex.eu

Image exemplary.

eplan download, configurators www.igus.eu/CF111D

Product rangePart No.

Number of cores and conductor nominal cross section [mm2]

External diameter max. [mm]

Copper index [kg/km]

Weight [kg/km]

€/m Part No. Core group Colour code

(3x(2x0.14)C+(4x0.14)+(2x0.5))C 9.0 63 104 3x(2x0.14)C green/yellow, black/brown, red/orange(4x0.14) grey/blue/white-yellow/white-black(2x0.5) brown-red/brown-blue

(3x(2x0.14)C+2x(0.5)C)C 9.5 65 108 3x(2x0.14)C green/yellow, black/brown, red/orange2x(0.5)C black, red

(2x(2x(2x0.14))+(4x0.14)C+(4x0.5))C 10.5 74 122 2x(2x(2x0.14)) (brown/green)/(yellow/violet), (grey/pink)/(red/black)(4x0.14)C yellow-black/red-black/green-black/blue-black

(4x0.5) brown-green/white-green/blue/white(3x(2x0.14)C+(4x0.14)+ 10.0 80 126 3x(2x0.14)C green/yellow, black/brown, red/orange

(4x0.25)+(2x0.5))C (4x0.14) grey/blue/white-yellow/white-black(4x0.25) brown-yellow/brown-grey/green-black/green-red(2x0.5) brown-red/brown-blue

(4x(2x0.25)+2x0.5)C 8.0 51 82 4x(2x0.25) brown/green, blue/violet, grey/pink, red/black2x0.5 white, brown

(4x(2x0.25)+2x1.0)C 8.5 63 96 4x(2x0.25) brown/green, blue/violet, grey/pink, red/black2x1.0 white, brown

(4x(2x0.34)+4x0.5)C 9.0 72 108 4x(2x0.34) black/brown, red/orange, green/yellow, blue/violet4x0.5 black-white, red-white, yellow-white, blue-white

(4x(2x0.25)C+(2x0.5))C 10.0 78 125 4x(2x0.25)C white/brown, green/yellow, grey/pink, blue/red(2x0.5) black no. 1/black no. 2

(4x(2x0.14)+4x0.5)C 8.0 49 76 4x(2x0.14) brown/green, yellow/violet, grey/pink, red/black4x0.5 blue, white, brown-green, white-green

(3x(2x0.14)+2x(4x0.14)+(2x0.5)C)C 8.5 54 92 3x(2x0.14) blue/red, black/violet, grey-pink/red-blue2x(4x0.14) green/grey/yellow/pink, white-green/white-yellow/brown-green/brown-yellow

(2x0.5) white/brown

Other types available on request.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core* New in 4/2014

New*

New*

New*

New*

Other types page 100

PUR Measuring system cable | CF111.DCF111.D

PUR 10 x d

CF111.D PUR

10 x d

The readychain® systems from igus® are completely pre-harnessed with chainflex® cables, hoses, screw attachments, metal parts etc.

Class 4.2.3 4 medium load requirements 2 travel distance up to 10 m 3 oil-resistant

393838

CF111.021.D CF111.021.D

CF111.022.D CF111.022.D

CF111.024.D CF111.024.D

CF111.027.D CF111.027.D

CF111.028.D CF111.028.D

CF111.035.D CF111.035.D

1,040 types from stock no cutting costs ... ... no minimum order quantity ...(up to 10 cuts of the same types) igus® GmbH Cologne | Tel. +49-2203 9649-800 Fax -222 | [email protected] | www.chainflex.eu

Image exemplary.

Product rangePart No.

Number of cores and conductor nominal cross section [mm2]

External diameter max. [mm]

Copper index [kg/km]

Weight [kg/km]

€/m Part No. Core group Colour code

((4x0.25)+3x(2x0.25+2x0.5))C 9.5 81 120 (4x0.25) white/brown/grey/black3x(2x0.25+2x0.5) black no.1/white/black no. 2/yellow, black no. 3/white/black

no. 4/grey, black no. 5/black/black no. 6/orange((2x0.25)+5x0.5)C 7.0 47 74 (2x0.25) white/brown

5x0.5 green, yellow, grey, pink, blue((4x0.14)+2x(2x0.34))C 7.0 37 63 (4x0.14) yellow/grey/violet/pink

2x(2x0.34) white-green/white, brown-green/blue(5x(2x0.14)+2x0.5)C 8.0 46 78 5x(2x0.14) brown/green, yellow/grey, white/violet, red/black, pink/blue

2x0.5 white-green, white-red(2x(2x0.15)+(2x0.38))C 8.0 37 75 2x(2x0.15) green/yellow, pink/blue

(2x0.38) red/black(4x(2x0.25)C+2x(2x0.5))C 11.0 90 144 4x(2x0.25)C white/brown, green/yellow, grey/pink, blue/red

2x(2x0.5) black no.1/black no.2, black no.3/black no.4

Other types available on request.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core

Order example: CF111.021.D – in your desired length (0.5 m steps)CF111.D chainflex® series .021 Code measuring system-type

Online order www.igus.eu/CF111D

Delivery time 24h or today.Delivery time means time until shipping of goods.

PUR Measuring system cable | CF111.DCF111.D

PUR 10 x d

CF111.D PUR

10 x d

Other types page 98

eplan download, configurators www.igus.eu/CF111D

Class 4.2.3 4 medium load requirements 2 travel distance up to 10 m 3 oil-resistant

4140

1,040 types from stock no cutting costs ... ... no minimum order quantity ...(up to 10 cuts of the same types) igus® GmbH Cologne | Tel. +49-2203 9649-800 Fax -222 | [email protected] | www.chainflex.eu

PUR Measuring system cable | CF113.DCF113.D

PUR 7.5 x d

CF113.D PUR

7.5 x d

Conductor Stranded conductor in especially bending-resistant version consisting of tinned copper wires (following EN 60228).

Core insulation Mechanically high-quality TPE mixture.

Core stranding According to measuring system specification.

Core identification According to measuring system specificationSchedule Delivery Program

Element shield Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical.

Inner jacket TPE mixture adapted to suit the requirements in e-chains®.

Overall shield Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical.

Outer jacket Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in e-chains® (following DIN VDE 0282 Part 10). Colour: yellow-green (similar to RAL 6018)

CFRIP Strip cables 50% faster: The tear strip is in the outer jacketVideo www.igus.eu/CFRIP

Bending radius moved minimum 7.5 x dfixed minimum 5 x d

Temperature moved -20 °C to +80 °Cfixed -40 °C to +80 °C

v max. unsupported/gliding

10 m/s, 5 m/s

a max. 50 m/s2

Travel distance Freely suspended travel distances and up to 100 m for gliding applications, Class 4

UV-resistance Medium

Nominal voltage 50 V

Testing voltage 500 V

Oil Oil-resistant (following DIN EN 50363-10-2), Class 3

Imag

e ex

empl

ary.

for maximum load requirements PUR outer jacket shielded oil-resistant and coolant-resistant notch-resistant flame-retardant hydrolysis-resistant and microbe-resistant PVC-free/halogen-free

Typical application areas for maximum load requirements almost unlimited resticance to oil indoor and outdoor applications without direct sun radiation freely suspended travel distances and up to 100 m for gliding applications Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, indoor cranes, low-temperature applications

Offshore MUD-resistant following NEK 606 - status 2009

Flame-retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Halogen-free Following EN 50267-2-1

Silicon-free Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992)

UL/CSA Style 1589 and 20236, 30 V, 80 °C

NFPA Following NFPA 79-2012 chapter 12.9

CEI Following CEI 20-35

CE Following 2006/95/EC

DESINA According to VDW, DESINA standardisation

Lead free Following 2011/65/EC (RoHS-II)

Clean room According to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D, tested by IPA according to standard 14644-1.

CTP Certified according to No. C-DE.PB49.B.00416

GL Certified according to GL Type Testing – Certificate No.: 61 936-14 HH

eplan download, configurators www.igus.eu/CF113D

New! Guaranteed lifetime for this series according to the "chainflex® guarantee club" conditions Page 4-5Double strokes* 5 million 7.5 million 10 million

Temperature, from/to [°C]

v max. [m/s] a max. Travel distance R min. R min. R min.

unsupported gliding [m/s2] [m] [factor x d] [factor x d] [factor x d]

-20 / -10

10 5 50 ≤ 100

10 11 12

-10 / +70 7.5 8.5 9.5

+70 / +80 10 11 12

* higher number of double strokes possible

Product improvement!

Strip cables 50% faster!

www.igus.eu/CFRIP

CFRIP-technology

®

Class 6.4.3 6 maximum load requirements 4 travel distance up to 100 m 3 oil-resistant

434242

CF113.001.D CF113.001.D

CF113.002.D CF113.002.D

CF113.003.D CF113.003.D

CF113.004.D CF113.004.D

CF113.005.D CF113.005.D

CF113.006.D CF113.006.D

CF113.007.D 2) CF113.007.D 2)

CF113.008.D CF113.008.DCF113.009.D CF113.009.D

CF113.010.D 1) CF113.010.D 1)

CF113.011.D 1) CF113.011.D 1)

CF113.012.D 1) CF113.012.D 1)

CF113.013.D CF113.013.D

CF113.014.D CF113.014.D

CF113.015.D CF113.015.D

CF113.016.D CF113.016.D

1,040 types from stock no cutting costs ... ... no minimum order quantity ...(up to 10 cuts of the same types) igus® GmbH Cologne | Tel. +49-2203 9649-800 Fax -222 | [email protected] | www.chainflex.eu

Image exemplary.

eplan download, configurators www.igus.eu/CF113D

Product rangePart No.

Number of cores and conductor nominal cross section [mm2]

External diameter max. [mm]

Copper index [kg/km]

Weight [kg/km]

€/m Part No. Core group Colour code

(3x(2x0.14)C+(4x0.14)+(2x0.5))C 10.5 80 180 3x(2x0.14)C green/yellow, black/brown, red/orange(4x0.14) grey/blue/white-yellow/white-black(2x0.5) brown-red/brown-blue

(3x(2x0.14)C+2x(0.5)C)C 10.5 82 193 3x(2x0.14)C green/yellow, black/brown, red/orange2x(0.5)C black, red

(3x(2x0.14)+2x1.0)C 8.5 61 130 3x(2x0.14) white/brown, green/yellow, grey/pink2x1.0 blue, red

(2x(2x(2x0.14))+(4x0.14)C+(4x0.5))C 11.5 91 204 2x(2x(2x0.14)) (brown/green)/(yellow/violet), (grey/pink)/(red/black)(4x0.14)C yellow-black/red-black/green-black/blue-black

(4x0.5) brown-green/white-green/blue/white(4x(2x0.14)+4x0.5)C 9.5 68 151 4x(2x0.14) white/brown, green/yellow, grey/pink, blue/red

4x0.5 black, violet, grey-pink, red-blue(3x(2x0.14)C+(4x0.14)+ 11.0 93 206 3x(2x0.14)C green/yellow, black/brown, red/orange

(4x0.25)+(2x0.5))C (4x0.14) grey/blue/white-yellow/white-black(4x0.25) brown-yellow/brown-grey/green-black/green-red(2x0.5) brown-red/brown-blue

(4x0.34)C 6.0 32 67 4x0.34 white, green, brown, yellow (star quad stranding)(3x(2x0.25))C 8.0 37 85 3x(2x0.25) white/brown, green/yellow, grey/pink

(4x(2x0.25)+2x0.5)C 9.5 66 143 4x(2x0.25) brown/green, blue/violet, grey/pink, red/black2x0.5 white, brown

(4x(2x0.25)+2x1.0)C 9.5 80 167 4x(2x0.25) brown/green, blue/violet, grey/pink, red/black2x1.0 white, brown

(4x(2x0.34)+4x0.5)C 10.5 96 208 4x(2x0.34) black/brown, red/orange, green/yellow, blue/violet4x0.5 black-white, red-white, yellow-white, blue-white

(3x(2x0.14)C+(3x0.14)C+ 11.5 99 229 3x(2x0.14)C green/yellow, white/grey, blue/red(4x0.14)+(2x0.14+2x0.5))C (3x0.14)C red/green/brown

(4x0.14) grey/yellow/pink/violet(2x0.14+2x0.5) blue/brown-blue/grey/brown-red

(3x(2x0.14)C+2x0.5)C 9.5 70 160 3x(2x0.14)C white/brown, green/yellow, grey/pink2x0.5 blue, red

(4x(2x0.25)C+(2x0.5))C 11.5 95 219 4x(2x0.25)C white/brown, green/yellow, grey/pink, blue/red(2x0.5) black no.1/black no.2

(4x(2x0.14)+4x0.5)C 9.5 68 147 4x(2x0.14) brown/green, yellow/violet, grey/pink, red/black4x0.5 blue, white, brown-green, white-green

(3x(2x0.25)C)C 9.5 65 147 3x(2x0.25)C white/brown, green/yellow, grey/pink

1) Delivery time upon request.The chainflex® types marked with 2) are cables designed as a star-quad.Other types available on request.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core Other types page 106/108

PUR Measuring system cable | CF113.DCF113.D

PUR 7.5 x d

CF113.D PUR

7.5 x d

Strip cables 50 % faster!

Class 6.4.3 6 maximum load requirements 4 travel distance up to 100 m 3 oil-resistant

4544

CF113.017.D 4) CF113.017.D 4)

CF113.018.D 1)/4) CF113.018.D 1)/(4)

CF113.019.D 4) CF113.019.D 4)

CF113.021.D 1) CF113.021.D 1)

CF113.022.D CF113.022.D

CF113.025.D CF113.025.D

CF113.027.D CF113.027.D

CF113.028.D 4) CF113.028.D 4)

CF113.029.D CF113.029.D

CF113.031.D CF113.031.D

CF113.032.D 15) CF113.032.D 15)

CF113.033.D 15) CF113.033.D 15)

1,040 types from stock no cutting costs ... ... no minimum order quantity ...(up to 10 cuts of the same types) igus® GmbH Cologne | Tel. +49-2203 9649-800 Fax -222 | [email protected] | www.chainflex.eu

Image exemplary.

eplan download, configurators www.igus.eu/CF113D

Product rangePart No.

Number of cores and conductor nominal cross section [mm2]

External diameter max. [mm]

Copper index [kg/km]

Weight [kg/km]

€/m Part No. Core group Colour code

(4x(2x0.14)+(4x0.14)C+4x1.0)C 11.5 116 252 4x(2x0.14) red/black, brown/green, yellow/violet, grey/pink(4x0.14)C blue-black/yellow-black/red-black/green-black

4x1.0 white-green, brown-green, blue, white(2x(2x0.25)+2x0.5)C 7.0 40 81 2x(2x0.25) red/black, grey/pink

2x0.5 white, brown(3x(2x0.25)C+(3x0.25)+2x1.0)C 11.5 106 235 3x(2x0.25)C brown/green, grey/pink, red/black

(3x0.25) blue/violet/yellow2x1.0 white, brown

((4x0.25)+3x(2x0.25+2x0.5))C 11.0 102 220 (4x0.25) white/brown/grey/blackblack no.1/white/black no.2/yellow, black no.3/white/black

3x(2x0.5+2x0.5) no.4/grey, black no.5/black/black no. 6/orange((2x0.25)+5x0.5)C 8.5 55 126 (2x0.25) white/brown

5x0.5 green, yellow, grey, pink, blue(3x(2x0.14)C+(2x0.5)C)C 11.0 81 188 3x(2x0.14)C green/yellow, blue/red, grey/pink

(2x0.5)C white/brown(5x(2x0.14)+2x0.5)C 9.0 58 127 5x(2x0.14) brown/green, yellow/grey, white/violet, red-black, pink/blue

2x0.5 white-green, white-red(2x(2x0.20)+(2x0.38))C 7.5 47 74 2x(2x0.20) green/yellow, pink/blue

(2x0.38) red/black(5x(2x0.25)C+(2x0.25+2x0.5))C 13.0 119 278 5x(2x0.25)C white/brown, green/yellow, grey/pink, blue/red, black/violet

(2x0.25+2x0.5) grey-pink/brown-green/white-green/red-blue(2x(2x0.25)C+2x1.0)C 9.0 76 161 2x(2x0.25)C white/brown, green/yellow

2x1.0 black no.1, black no.23x(2x0.14)C+(3x0.14)C 9.5 68 155 3x(2x0.14)C green/black, yellow/black, red/black

(3x0.14)C grey/pink/black4x(2x0.14)C+2x(1.0)C 11.5 107 247 4x(2x0.14)C yellow/black, red/black, blue/black, green/black

2x(1.0)C white, brown1) Delivery time upon request.4) manufactured without inner jacket.15) manufactured without overall shieldOther types available on request.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core

Other types page 104/108

PUR Measuring system cable | CF113.DCF113.D

PUR 7.5 x d

CF113.D PUR

7.5 x d

Strip cables 50 % faster!

Class 6.4.3 6 maximum load requirements 4 travel distance up to 100 m 3 oil-resistant

474646

CF113.034.D 15) CF113.034.D 15)

CF113.035.D CF113.035.D

CF113.036.D CF113.036.DCF113.037.D CF113.037.D

CF113.038.D CF113.038.D

CF113.040.D CF113.040.D

1,040 types from stock no cutting costs ... ... no minimum order quantity ...(up to 10 cuts of the same types) igus® GmbH Cologne | Tel. +49-2203 9649-800 Fax -222 | [email protected] | www.chainflex.eu

Image exemplary.

eplan download, configurators www.igus.eu/CF113D

Product rangePart No.

Number of cores and conductor nominal cross section [mm2]

External diameter max. [mm]

Copper index [kg/km]

Weight [kg/km]

€/m Part No. Core group Colour code

3x(2x0.14)C+(4x0.14)C+2x(2x0.5)C 12.5 116 201 3x(2x0.14)C green/black, violet/black, blue/black(4x0.14)C red/yellow/black-red/black-yellow

2x(2x0.5)C black/white, black/brown(4x(2x0.25)C+2x(2x0.5))C 12.5 114 261 4x(2x0.25)C white/brown, green/yellow, grey/pink, blue/red

2x(2x0.5) black no.1/black no.2, black no.3/black no.4(5x(2x0.25))C 9.5 58 108 5x(2x0.25) white/brown, green/yellow, grey/pink, blue/red, black/violet(6x(2x0.25))C 10.0 69 120 6x(2x0.25) white/brown, green/yellow, grey/pink, blue/red, black/violet,

grey-pink/red-blue(3x(2x0.14)+(2x0.34))C 8.0 36 71 3x(2x0.14) white/brown, green/yellow, grey/pink

(2x0.34) blue/red(3x(4x0.14)+(2x0.14+2x0.34)+2x1.5)C 10.5 101 165 3x(4x0.14) black/red/white-black/white-red, green/blue/white-green/white-blue,

yellow/brown/white-yellow/white-brown

(2x0.14+2x0.34) violet/orange/white-violet/white-orange2x1.5 white-grey, grey

15) manufactured without overall shieldOther types available on request.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core

Other types page 104/106

PUR Measuring system cable | CF113.DCF113.D

PUR 7.5 x d

CF113.D PUR

7.5 x d

Strip cables 50 % faster!

Order example: CF113.035.D – in your desired length (0.5 m steps)CF113.D chainflex® series .035 Code measuring system-type

Online order www.igus.eu/CF113D

Delivery time 24h or today.Delivery time means time until shipping of goods.

chainflex® measuring system cable in a double-spindle horizontal machining centre.

Class 6.4.3 6 maximum load requirements 4 travel distance up to 100 m 3 oil-resistant

4948

1,040 types from stock no cutting costs ... ... no minimum order quantity ...(up to 10 cuts of the same types) igus® GmbH Cologne | Tel. +49-2203 9649-800 Fax -222 | [email protected] | www.chainflex.eu

PUR Servo cable | CF27.DCF27.D

PUR7.5 x d

CF27.DPUR

7.5 x d

Conductor Stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228).

Core insulation Mechanically high-quality, especially low-capacitance TPE mixture.

Core identification Energy conductor: Cores black with white numerals, one core green-yellow.1. Core: U / L1 / C / L+ 2. Core: V / L2 3. Core: W / L3 / D / L-1 Signal pair: Cores black with white numerals.1. Control core: 4 2. Control core: 52 Signal pairs: Cores black with white numerals.1. Control core: 5 2. Control core: 63. Control core: 7 4. Control core: 8 Star-quad: yellow, black, red, white

Core stranding Energy conductor with signal pair elements stranded together with elements for high tensile stresses.

Element shield Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical.

Inner jacket PUR mixture adapted to suit the requirements in e-chains®.

Overall shield Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical.

Outer jacket Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in e-chains® (following DIN VDE 0282 Part 10). Colour: Pastel orange (similar to RAL 2003)

Bending radius moved minimum 7.5 x dfixed minimum 4 x d

Temperature moved -20 °C to +80 °Cfixed -40 °C to +80 °C

v max. unsupported/gliding

10 m/s, 5 m/s

a max. 80 m/s2

Travel distance Freely suspended travel distances and up to 100 m for gliding applications, Class 4

UV-resistance Medium

Nominal voltage 600/1000 V (following DIN VDE 0250)

Imag

e ex

empl

ary.

for maximum load requirements PUR outer jacket shielded oil-resistant and coolant-resistant notch-resistant flame-retardant hydrolysis-resistant and microbe-resistant PVC-free/halogen-free

Typical application areas for maximum load requirements almost unlimited resticance to oil indoor and outdoor applications, UV-resistant freely suspended travel distances and up to 100 m for gliding applications Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, outdoor cranes, low-temperature applications

Testing voltage 4000 V (following DIN VDE 0281-2)

Oil Oil-resistant (following DIN EN 50363-10-2), Class 3

Offshore MUD-resistant following NEK 606 - status 2009

Flame-retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992)

Halogen-free Following EN 50267-2-1

UL/CSA Style 10492 and 20234, 1000 V, 80 °C

NFPA Following NFPA 79-2012 chapter 12.9

CEI Following CEI 20-35

CE Following 2006/95/EC

DESINA According to VDW, DESINA standardisation

Lead free Following 2011/65/EC (RoHS-II)

Clean room According to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D, tested by IPA according to standard 14644-1.

CTP Certified according to No. C-DE.PB49.B.00420

EAC Certified according to No. TC RU C-DE.ME77.B.01255

GL Certified according to GL Type Testing – Certificate No.: 61 938-14 HH

eplan download, configurators www.igus.eu/CF27D

New! Guaranteed lifetime for this series according to the "chainflex® guarantee club" conditions Page 4-5Double strokes* 5 million 7.5 million 10 million

Temperature, from/to [°C]

v max. [m/s] a max. Travel distance R min. R min. R min.

unsupported gliding [m/s2] [m] [factor x d] [factor x d] [factor x d]

-20 / -10

10 5 80 ≤ 100

10 11 12

-10 / +70 7.5 8.5 8.5

+70 / +80 10 11 12

* higher number of double strokes possible

Test data page 56

Class 6.4.3 6 maximum load requirements 4 travel distance up to 100 m 3 oil-resistant

5150

CF27.07.05.02.01.DCF27.15.15.02.01.DCF27.25.15.02.01.DCF27.40.15.02.01.DCF27.60.15.02.01.DCF27.100.15.02.01.DCF27.160.15.02.01.DCF27.250.15.02.01.DCF27.350.15.02.01.D

CF27.07.03.02.02.DCF27.10.07.02.02.DCF27.15.07.02.02.DCF27.25.15.02.02.DCF27.40.15.02.02.DCF27.60.15.02.02.DCF27.100.15.02.02.DCF27.160.15.02.02.DCF27.250.15.02.02.DCF27.350.15.02.02.D 1)

CF27.15.05.04.DCF27.25.05.04.DCF27.40.05.04.DCF27.60.05.04.D

CF27.07.04.D 1)

CF27.10.04.D 1)

CF27.15.04.DCF27.25.04.DCF27.500.04.D

1,040 types from stock no cutting costs ... ... no minimum order quantity ...(up to 10 cuts of the same types) igus® GmbH Cologne | Tel. +49-2203 9649-800 Fax -222 | [email protected] | www.chainflex.eu

Image exemplary.

eplan download, configurators www.igus.eu/CF27D

Product rangePart No.

Number of cores and conductor nominal cross section [mm2]

External diameter max. [mm]

Copper index [kg/km]

Weight [kg/km]

€/m

1 Signal pair shielded(4 G 0.75+(2x0.5)C)C 11.5 95 175(4 G 1.5+(2x1.5)C)C 13.0 144 260(4 G 2.5+(2x1.5)C)C 14.5 199 325(4 G 4.0+(2x1.5)C)C 16.0 257 402(4 G 6.0+(2x1.5)C)C 17.5 357 580

(4 G 10.0+(2x1.5)C)C 21.5 540 900(4 G 16.0+(2x1.5)C)C 24.5 716 1150(4 G 25.0+(2x1.5)C)C 28.5 1140 1523(4 G 35.0+(2x1.5)C)C 32.5 1560 2079

2 Signal pairs shielded(4 G 0.75+2x(2x0.34)C)C 12.5 105 206(4 G 1.0+2x(2x0.75)C)C 13.5 152 265(4 G 1.5+2x(2x0.75)C)C 14.0 175 300(4 G 2.5+2x(2x1.5)C)C 16.5 265 412(4 G 4.0+2x(2x1.5)C)C 18.0 314 485(4 G 6.0+2x(2x1.5)C)C 20.0 410 643

(4 G 10.0+2x(2x1.5)C)C 23.5 594 1000(4 G 16.0+2x(2x1.5)C)C 26.0 790 1250(4 G 25.0+2x(2x1.5)C)C 31.0 1200 1890(4 G 35.0+2x(2x1.5)C)C 33.5 1597 2150

1 Star-quad shielded(4 G 1.5+(4x0.5)C)C 13.0 142 310(4 G 2.5+(4x0.5)C)C 14.5 199 348(4 G 4.0+(4x0.5)C)C 16.0 256 480(4 G 6.0+(4x0.5)C)C 17.5 371 550

1) Delivery time upon request.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core

Product rangePart No.

Number of cores and conductor nominal cross section [mm2]

External diameter max. [mm]

Copper index [kg/km]

Weight [kg/km]

€/m

Without signal pair(4 G 0.75)C 9.5 52 113(4 G 1.0)C 10.0 62 126(4 G 1.5)C 10.5 86 163(4 G 2.5)C 12.5 140 260

(4 G 50.0)C 37.0 2230 3200

1) Delivery time upon request.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core

PUR Servo cable | CF27.DCF27.D

PUR7.5 x d

CF27.DPUR

7.5 x d

Order example: CF27.15.10.02.01.D – in your desired length (0.5 m steps)CF27 chainflex® Serie .15 Code nominal cross section .10 Code nominal cross section signal pairs

.02 Identification pairs .01 Number of pairs

Online order www.igus.eu/CF27D

Delivery time 24h or today.Delivery time means time until shipping of goods.

Modular design, easy to retrofit: igus® E4 energy supply system and chainflex® cables.

Class 6.4.3 6 maximum load requirements 4 travel distance up to 100 m 3 oil-resistant

5352

1,040 types from stock no cutting costs ... ... no minimum order quantity ...(up to 10 cuts of the same types) igus® GmbH Cologne | Tel. +49-2203 9649-800 Fax -222 | [email protected] | www.chainflex.eu

TPE Motor cable | CF34.UL.DCF34.UL.D

TPE7.5 x d

CF34.UL.DTPE

7.5 x d

Conductor ≥ 10 mm2: Stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228).< 10 mm2: Conductor cable consisting of pre-leads (following EN 60228).

Core insulation Mechanically high-quality, especially low-capacitance TPE mixture.

Core stranding Cores stranded in short pitch lengths over a centre for high tensile stresses.

Core identification Energy conductor: Cores black with white numerals, one core green-yellow.1. Core: U / L1 / C / L+ 2. Core: V / L2 3. Core: W / L3 / D / L- 4. Core: 4 / N

Outer jacket Low-adhesion mixture on the basis of TPE, especially abrasion-resistant and highly flexible, adapted to suit the requirements in e-chains®. Colour: Jet black (similar to RAL 9005)

CFRIP Strip cables 50% faster: The tear strip is in the outer jacket(starting from manufacturing date 5/2013) Video www.igus.eu/CFRIP

Bending radius moved minimum 7.5 x dfixed minimum 4 x d

Temperature moved -35 °C to +90 °Cfixed -40 °C to +90 °C

v max. unsupported/gliding

10 m/s, 6 m/s

a max. 80 m/s2

Travel distance Freely suspended travel distances and up to 400 m for gliding applications, Class 5

Torsion ± 90°, with 1 m cable length

UV-resistance High

Nominal voltage 600/1000 V (following DIN VDE 0250)

Testing voltage 4000 V (following DIN VDE 0281-2)

Oil Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4

Imag

e ex

empl

ary.

for maximum load requirements TPE outer jacket oil-resistant bio-oil-resistant flame-retardant UV-resistant hydrolysis-resistant and microbe-resistant

Typical application areas for maximum load requirements almost unlimited resistance to oil, also with bio-oils indoor and outdoor applications, UV-resistant freely suspended travel distances and up to 400 m for gliding applications Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications

Flame-retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992)

UL/CSA Style 10492 and 21184, 1000 V, 80 °C

NFPA Following NFPA 79-2012 chapter 12.9

CEI Following CEI 20-35

CE Following 2006/95/EC

DESINA According to VDW, DESINA standardisation

Lead free Following 2011/65/EC (RoHS-II)

Clean room According to ISO Class 1, material/cable tested by IPA according to ISO standard 14644-1

CTP Certified according to No. C-DE.PB49.B.00420

EAC Certified according to No. TC RU C-DE.ME77.B.01255

GL Certified according to GL Type Testing – Certificate No.: 61 938-14 HH

eplan download, configurators www.igus.eu/CF34

New! Guaranteed lifetime for this series according to the "chainflex® guarantee club" conditions Page 4-5Double strokes* 5 million 7.5 million 10 million

Temperature, from/to [°C]

v max. [m/s] a max. Travel distance R min. R min. R min.

unsupported gliding [m/s2] [m] [factor x d] [factor x d] [factor x d]

-35 / -25

10 6 80 ≤ 400

10 11 12

-25 / +80 7.5 8.5 9.5

+80 / +90 10 11 12

* higher number of double strokes possible

Product improvement!

Strip cables 50% faster!

www.igus.eu/CFRIP

CFRIP-technology

®

www.igus.eu/CFRIP

Class 6.5.4 6 maximum load requirements 5 travel distance up to 400 m 4 oil-resistant

5554

CF34.UL.15.04.DCF34.UL.25.04.DCF34.UL.40.04.DCF34.UL.60.04.DCF34.UL.60.05.DCF34.UL.100.04.DCF34.UL.100.05.DCF34.UL.160.04.DCF34.UL.160.05.D

CF34.UL.250.04.D

CF34.UL.60.04.O.PE.D 1)

CF34.UL.100.04.O.PE.DCF34.UL.160.04.O.PE.DCF34.UL.500.03.O.PE.D

1,040 types from stock no cutting costs ... ... no minimum order quantity ...(up to 10 cuts of the same types) igus® GmbH Cologne | Tel. +49-2203 9649-800 Fax -222 | [email protected] | www.chainflex.eu

Product rangePart No.

Number of cores and conductor nominal cross section [mm2]

External diameter max. [mm]

Copper index [kg/km]

Weight [kg/km]

€/m

4 G 1.5 8.5 58 1094 G 2.5 10.5 96 1624 G 4.0 12.0 158 2394 G 6.0 14.0 239 3515 G 6.0 15.5 285 420

4 G 10.0 17.0 411 5495 G 10.0 19.5 517 6874 G 16.0 20.5 633 8175 G 16.0 23.0 800 10724 G 25.0 25.0 994 1266

4 x 6 14.0 239 3514 x 10 17.0 411 5494 x 16 20.5 633 8173 x 50 31.0 1490 2028

1) Delivery time on request.Other types available on request. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core

TPE Motor cable | CF34.UL.DCF34.UL.D

TPE7.5 x d

CF34.UL.DTPE

7.5 x d

Image exemplary.

eplan download, configurators www.igus.eu/CF34

Order example: CF34.UL.160.04.D – in your desired length (0.5 m steps)CF34.UL.D chainflex® series .160 Code nominal cross section .04 Number of cores

Online order www.igus.eu/CF34

Delivery time 24h or today.Delivery time means time until shipping of goods.

Strip cables 50 % faster!

Class 6.5.4 6 maximum load requirements 5 travel distance up to 400 m 4 oil-resistant

5756

1,040 types from stock no cutting costs ... ... no minimum order quantity ...(up to 10 cuts of the same types) igus® GmbH Cologne | Tel. +49-2203 9649-800 Fax -222 | [email protected] | www.chainflex.eu

TPE Motor cable | CF35.ULCF35.UL

TPE7.5 x d

CF35.ULTPE

7.5 x d

Conductor ≥ 10 mm2: Stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228).< 10 mm2: Conductor cable consisting of pre-leads (following EN 60228).

Core insulation Mechanically high-quality, especially low-capacitance TPE mixture.

Core stranding Cores stranded in short pitch lengths over a centre for high tensile stresses.

Core identification Energy conductor: Cores black with white numerals, one core green-yellow.1. Core: U / L1 / C / L+ 2. Core: V / L2 3. Core: W / L3 / D / L- 4. Core: 4 / N

Inner jacket TPE mixture adapted to suit the requirements in e-chains®.

Overall shield Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical.

Outer jacket Low-adhesion mixture on the basis of TPE, especially abrasion-resistant and highly flexible, adapted to suit the requirements in e-chains®. Colour: Jet black (similar to RAL 9005)

CFRIP Strip cables 50% faster: The tear strip is in the inner jacket(starting from manufacturing date 5/2013) Video www.igus.eu/CFRIP

Bending radius moved minimum 7.5 x dfixed minimum 4 x d

Temperature moved -35 °C to +90 °Cfixed -40 °C to +90 °C

v max. unsupported/gliding

10 m/s, 6 m/s

a max. 80 m/s2

Travel distance Freely suspended travel distances and up to 400 m for gliding applications, Class 5

UV-resistance High

Nominal voltage 600/1000 V (following DIN VDE 0250)

Testing voltage 4000 V (following DIN VDE 0281-2)

Oil Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4

Imag

e ex

empl

ary.

for maximum load requirements TPE outer jacket shielded oil-resistant, bio-oil-resistant flame-retardant UV-resistant hydrolysis-resistant and microbe-resistant

Typical application areas for maximum load requirements almost unlimited resistance to oil, also with bio-oils indoor and outdoor applications, UV-resistant freely suspended travel distances and up to 400 m for gliding applications Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications

Flame-retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992)

UL/CSA Style 10492 and 21184, 1000 V, 80 °C

NFPA Following NFPA 79-2012 chapter 12.9

CEI Following CEI 20-35

CE Following 2006/95/EC

Lead free Following 2011/65/EC (RoHS-II)

Clean room According to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, tested by IPA according to standard 14644-1

CTP Certified according to No. C-DE.PB49.B.00420

EAC Certified according to No. TC RU C-DE.ME77.B.01255

GL Certified according to GL Type Testing – Certificate No.: 61 938-14 HH

eplan download, configurators www.igus.eu/CF35

New! Guaranteed lifetime for this series according to the "chainflex® guarantee club" conditions Page 4-5Double strokes* 5 million 7.5 million 10 million

Temperature, from/to [°C]

v max. [m/s] a max. Travel distance R min. R min. R min.

unsupported gliding [m/s2] [m] [factor x d] [factor x d] [factor x d]

-35 / -25

10 6 80 ≤ 400

10 11 12

-25 / +80 7.5 8.5 9.5

+80 / +90 10 11 12

* higher number of double strokes possible

Product improvement!

Strip cables 50% faster!

www.igus.eu/CFRIP

CFRIP-technology

®

www.igus.eu/CFRIP

Class 6.5.4 6 maximum load requirements 5 travel distance up to 400 m 4 oil-resistant

5958

CF35.UL.05.04CF35.UL.07.04CF35.UL.15.04CF35.UL.25.04CF35.UL.40.04CF35.UL.60.04CF35.UL.100.04CF35.UL.160.04CF35.UL.250.04

CF35.UL.60.03.O.PE 1)

CF35.UL.100.03.O.PE 1)

CF35.UL.160.03.O.PECF35.UL.250.03.O.PE 1)

CF35.UL.350.03.O.PECF35.UL.500.03.O.PE

1,040 types from stock no cutting costs ... ... no minimum order quantity ...(up to 10 cuts of the same types) igus® GmbH Cologne | Tel. +49-2203 9649-800 Fax -222 | [email protected] | www.chainflex.eu

Product rangePart No.

Number of cores and conductor nominal cross section [mm2]

External diameter max. [mm]

Copper index [kg/km]

Weight [kg/km]

€/m

(4 G 0.5)C 8.0 39 81(4 G 0.75)C 8.5 52 104(4 G 1.5)C 9.5 85 149(4 G 2.5)C 11.5 128 207(4 G 4.0)C 13.5 201 326(4 G 6.0)C 16.0 298 450

(4 G 10.0)C 19.5 454 682(4 G 16.0)C 23.0 723 1003(4 G 25.0)C 27.5 1160 1524

(3 x 6.0)C 14.5 231 367(3 x 10.0)C 17.5 356 568(3 x 16.0)C 21.0 553 789(3 x 25.0)C 24.5 884 1208(3 x 35.0)C 28.5 1200 1675(3 x 50.0)C 33.5 1660 2283

1) Delivery time on request.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core

Image exemplary.

eplan download, configurators www.igus.eu/CF35

Order example: CF35.UL.15.04 – in your desired length (0.5 m steps)CF35.UL chainflex® series .15 Code nominal cross section .04 Number of cores

Online order www.igus.eu/CF35

Delivery time 24h or today.Delivery time means time until shipping of goods.

Strip cables 50 % faster!

TPE Motor cable | CF35.ULCF35.UL

TPE7.5 x d

CF35.ULTPE

7.5 x d Class 6.5.4 6 maximum load requirements 5 travel distance up to 400 m 4 oil-resistant

6160

CF300.UL.40.01.DCF300.UL.60.01.DCF300.UL.100.01.DCF300.UL.160.01.DCF300.UL.250.01.DCF300.UL.350.01.DCF300.UL.500.01.DCF300.UL.700.01.DCF300.UL.950.01.DCF300.UL.1200.01.DCF300.UL.1500.01.DCF300.UL.1850.01.D

1,040 types from stock no cutting costs ... ... no minimum order quantity ...(up to 10 cuts of the same types) igus® GmbH Cologne | Tel. +49-2203 9649-800 Fax -222 | [email protected] | www.chainflex.eu

TPE Motor cable | CF300.UL.DCF300.UL.D

TPE7.5 x d

CF300.UL.DTPE

7.5 x d

Conductor Conductor cable consisting of pre-leads (following EN 60228).

Core insulation Mechanically high-quality TPE mixture.

Outer jacket Low-adhesion mixture on the basis of TPE, especially abrasion-resistant and highly flexible, adapted to suit the requirements in e-chains®. Colour: Jet black (similar to RAL 9005)

Bending radius moved minimum 7.5 x dfixed minimum 4 x d

Temperature moved -35 °C to +90 °Cfixed -40 °C to +90 °C

v max. unsupported/gliding

10 m/s, 6 m/s

a max. 100 m/s2

Travel distance Freely suspended travel distances and up to 400 m for gliding applications, Class 5

Torsion ± 90°, with 1 m cable length

UV-resistance High

Nominal voltage 600/1000 V (following DIN VDE 0250)

Testing voltage 4000 V (following DIN VDE 0281-2)

Oil Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4

Flame-retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992)

UL/CSA Style 10492 and 21218, 1000 V, 80 °C

NFPA Following NFPA 79-2012 chapter 12.9

CEI Following CEI 20-35

CE Following 2006/95/EC

Imag

e ex

empl

ary.

for maximum load requirements TPE outer jacket oil-resistant, bio-oil-resistant flame-retardant UV-resistant hydrolysis-resistant and microbe-resistant

Typical application areas for maximum load requirements almost unlimited resistance to oil, also with bio-oils indoor and outdoor applications, UV-resistant freely suspended travel distances and up to 400 m for gliding applications Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications

DESINA According to VDW, DESINA standardisation

Lead free Following 2011/65/EC (RoHS-II)

Clean room According to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, tested by IPA according to standard 14644-1

CTP Certified according to No. C-DE.PB49.B.00420

EAC Certified according to No. TC RU C-DE.ME77.B.01255

GL Certified according to GL Type Testing – Certificate No.: 61 938-14 HH

eplan download, configurators www.igus.eu/CF300

New! Guaranteed lifetime for this series according to the "chainflex® guarantee club" conditions Page 4-5Double strokes* 5 million 7.5 million 10 million

Temperature, from/to [°C]

v max. [m/s] a max. Travel distance R min. R min. R min.

unsupported gliding [m/s2] [m] [factor x d] [factor x d] [factor x d]

-35 / -25

10 6 100 ≤ 400

10 11 12

-25 / +80 7.5 8.5 9.5

+80 / +90 10 11 12

* higher number of double strokes possible

Product rangePart No.

Number of cores and conductor nominal cross section [mm2]

External diameter max. [mm]

Copper index [kg/km]

Weight [kg/km]

€/m

1 x 4.0 6.5 38 611 x 6.0 7.0 62 83

1 x 10.0 8.0 106 1281 x 16.0 9.5 167 1971 x 25.0 11.5 264 3001 x 35.0 12.5 370 4111 x 50.0 14.5 528 5701 x 70.0 16.5 766 8101 x 95.0 19.0 1009 1088

1 x 120.0 21.5 1276 13571 x 150.0 23.0 1529 15521 x 185.0 27.0 2079 2167

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core

Class 6.5.4 6 maximum load requirements 5 travel distance up to 400 m 4 oil-resistant

6362

CFPE.15.01CFPE.25.01CFPE.40.01CFPE.60.01CFPE.100.01CFPE.160.01CFPE.250.01CFPE.350.01CFPE.500.01CFPE.700.01CFPE.950.01

1,040 types from stock no cutting costs ... ... no minimum order quantity ...(up to 10 cuts of the same types) igus® GmbH Cologne | Tel. +49-2203 9649-800 Fax -222 | [email protected] | www.chainflex.eu

TPE Motor cable | CFPECFPETPE

7.5 x d

CFPETPE

7.5 x d

Conductor Conductor cable consisting of pre-leads (following EN 60228).

Core insulation Mechanically high-quality TPE mixture.

Core identification Green-yellow

Outer jacket Low-adhesion mixture on the basis of TPE, especially abrasion-resistant and highly flexible, adapted to suit the requirements in e-chains®. Colour: Jet black (similar to RAL 9005)

Bending radius moved minimum 7.5 x dfixed minimum 4 x d

Temperature moved -35 °C to +90 °Cfixed -40 °C to +90 °C

v max. unsupported/gliding

10 m/s, 6 m/s

a max. 100 m/s2

Travel distance Freely suspended travel distances and up to 400 m for gliding applications, Class 5

Torsion ± 90°, with 1 m cable length

UV-resistance High

Nominal voltage 600/1000 V (following DIN VDE 0250)

Testing voltage 4000 V (following DIN VDE 0281-2)

Oil Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4

Flame-retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992)

UL/CSA Style 10492 and 21218, 1000 V, 80 °C

NFPA Following NFPA 79-2012 chapter 12.9

Imag

e ex

empl

ary.

for maximum load requirements TPE outer jacket oil-resistant, bio-oil-resistant flame-retardant UV-resistant hydrolysis-resistant and microbe-resistant

Typical application areas for maximum load requirements almost unlimited resistance to oil, also with bio-oils indoor and outdoor applications, UV-resistant freely suspended travel distances and up to 400 m for gliding applications Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications

CEI Following CEI 20-35

CE Following 2006/95/EC

Lead free Following 2011/65/EC (RoHS-II)

Clean room According to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, tested by IPA according to standard 14644-1

CTP Certified according to No. C-DE.PB49.B.00420

EAC Certified according to No. TC RU C-DE.ME77.B.01255

GL Certified according to GL Type Testing – Certificate No.: 61 938-14 HH

eplan download, configurators www.igus.eu/CFPE

New! Guaranteed lifetime for this series according to the "chainflex® guarantee club" conditions Page 4-5Double strokes* 5 million 7.5 million 10 million

Temperature, from/to [°C]

v max. [m/s] a max. Travel distance R min. R min. R min.

unsupported gliding [m/s2] [m] [factor x d] [factor x d] [factor x d]

-35 / -25

10 6 100 ≤ 400

10 11 12

-25 / +80 7.5 8.5 9.5

+80 / +90 10 11 12

* higher number of double strokes possible

Product rangePart No.

Number of cores and conductor nominal cross section [mm2]

External diameter max. [mm]

Copper index [kg/km]

Weight [kg/km]

€/m

1 G 1.5 5.0 15 351 G 2.5 6.0 25 461 G 4.0 6.5 38 611 G 6.0 7.0 62 83

1 G 10.0 8.0 106 1281 G 16.0 9.5 167 1971 G 25.0 11.5 264 3001 G 35.0 13.0 370 4111 G 50.0 14.5 528 5701 G 70.0 16.5 766 8101 G 90.0 20.0 1009 1088

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core* New in 4/2014

New*

New*

New*

Class 6.5.4 6 maximum load requirements 5 travel distance up to 400 m 4 oil-resistant

6564

CF310.UL.25.01CF310.UL.40.01CF310.UL.60.01CF310.UL.100.01CF310.UL.160.01CF310.UL.250.01CF310.UL.350.01CF310.UL.500.01CF310.UL.700.01CF310.UL.950.01CF310.UL.1200.01CF310.UL.1500.01CF310.UL.1850.01

1,040 types from stock no cutting costs ... ... no minimum order quantity ...(up to 10 cuts of the same types) igus® GmbH Cologne | Tel. +49-2203 9649-800 Fax -222 | [email protected] | www.chainflex.eu

TPE Motor cable | CF310.ULCF310.UL

TPE7.5 x d

CF310.ULTPE

7.5 x d

Conductor Conductor cable consisting of pre-leads (following EN 60228).

Core insulation Mechanically high-quality TPE mixture.

Overall shield Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical.

Outer jacket Low-adhesion mixture on the basis of TPE, especially abrasion-resistant and highly flexible, adapted to suit the requirements in e-chains®. Colour: Jet black (similar to RAL 9005)

Bending radius moved minimum 7.5 x dfixed minimum 4 x d

Temperature moved -35 °C to +90 °Cfixed -40 °C to +90 °C

v max. unsupported/gliding

10 m/s, 6 m/s

a max. 100 m/s2

Travel distance Freely suspended travel distances and up to 400 m for gliding applications, Class 5

UV-resistance High

Nominal voltage 600/1000 V (following DIN VDE 0250)

Testing voltage 4000 V (following DIN VDE 0281-2)

Oil Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4

Flame-retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992)

UL/CSA Style 10492 and 21218, 1000 V, 80 °C

NFPA Following NFPA 79-2012 chapter 12.9

CEI Following CEI 20-35

CE Following 2006/95/EC

Imag

e ex

empl

ary.

for maximum load requirements TPE outer jacket shielded oil-resistant, bio-oil-resistant flame-retardant UV-resistant hydrolysis-resistant and microbe-resistant

Typical application areas for maximum load requirements almost unlimited resistance to oil, also with bio-oils indoor and outdoor applications, UV-resistant freely suspended travel distances and up to 400 m for gliding applications Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications

Lead free Following 2011/65/EC (RoHS-II)

Clean room According to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, tested by IPA according to standard 14644-1

CTP Certified according to No. C-DE.PB49.B.00420

EAC Certified according to No. TC RU C-DE.ME77.B.01255

GL Certified according to GL Type Testing – Certificate No.: 61 938-14 HH

eplan download, configurators www.igus.eu/CF310

New! Guaranteed lifetime for this series according to the "chainflex® guarantee club" conditions Page 4-5Double strokes* 5 million 7.5 million 10 million

Temperature, from/to [°C]

v max. [m/s] a max. Travel distance R min. R min. R min.

unsupported gliding [m/s2] [m] [factor x d] [factor x d] [factor x d]

-35 / -25

10 6 100 ≤ 400

10 11 12

-25 / +80 7.5 8.5 9.5

+80 / +90 10 11 12

* higher number of double strokes possible

Product rangePart No.

Number of cores and conductor nominal cross section [mm2]

External diameter max. [mm]

Copper index [kg/km]

Weight [kg/km]

€/m

(1 x 2.5)C 6.5 39 61(1 x 4.0)C 7.0 60 80(1 x 6.0)C 7.5 83 105

(1 x 10.0)C 8.5 129 155(1 x 16.0)C 10.0 196 227(1 x 25.0)C 11.5 299 337(1 x 35.0)C 13.5 422 459(1 x 50.0)C 15.0 578 620(1 x 70.0)C 17.5 840 893(1 x 95.0)C 20.5 1095 1172

(1 x 120.0)C 22.0 1364 1439(1 x 150.0)C 24.0 1595 1678(1 x 185.0)C 28.0 2228 2313

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core

Class 6.5.4 6 maximum load requirements 5 travel distance up to 400 m 4 oil-resistant

igus® GmbH Spicher Straße 1a 51147 Cologne GermanyPhone +49-2203 9649-800 Fax +49-2203 [email protected] www.igus.eu

© 2014 igus® GmbH

Subject to technical alterations. MAT0072981.20 Issue 08/2014