INfIEGRITY TESTING LABORATORIES, Hardware Resources 4319 Marlena Street Bossier City, LA 71111 Attention: Grant Knuckolls LABORATORY NO: FlO08271-2 DATE: August 27,2010 CLIENT P.O. NO.: Vbl, G. Knuckolls STANDARD: ANSIIBHMA AI56.9-03 SAMPLE: 18" SIDE MOUNT BALL BEARING DRAWER SLIDE, 303FUSFTI8, TESTED WITH A 24 INCH WIDE TEST DRAWER This report serves to document the testing of the above sample to all applicable drawer test paragraphs of ANSIIBHMA 156.9-2003, American national standards for cabinet hardware. Test procedures include a drawer slide stop test, drawer removal and load placement test, drawer cycle testing and edge load application. The remainder of this report will show how the drawer slides submitted for testing met the requirements needed for conformance to the standard. All procedures were performed with strict adherence to the ANSIIBHMA A156.9 standard with one exception. The drawer test load was increased to 100 lbs, instead of the 50 lb. Minimum requirement. All procedures were performed with this test load. o the sample or samplessubmitted for testingand is notnecessarily indicativeofthe quality or condition of apparently identical or similar products. As a mutual protection to clients, tire laboratories, this report is submitted and accepted for the exclusive use of the client to whom it is addressed, and upon thatcondition that it not be used, in whole or in part, in a.l1Y ~advertising6t publicity matter without priorwritten authorization from these laboratories. G:\~1YDoOillllentsulQitNITURE REPORTSIHardware resourceslFl008271-2, 303FUSPT18 BHMA.doc ,

Upload: lehanh

Post on 01-Jul-2018

221 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: INfIEGRITY TESTING LABORATORIES, - Nexcess CDNlghttp.31392.nexcesscdn.net/80DFAD/production/media/pdf/specs/303... · INfIEGRITY TESTING LABORATORIES, Hardware Resources 4319 Marlena

INfIEGRITY TESTING LABORATORIES,

Hardware Resources4319 Marlena StreetBossier City, LA 71111Attention: Grant Knuckolls

LABORATORY NO: FlO08271-2DATE: August 27,2010CLIENT P.O. NO.: Vbl, G. KnuckollsSTANDARD: ANSIIBHMA AI56.9-03

SAMPLE: 18" SIDE MOUNT BALL BEARING DRAWER SLIDE, 303FUSFTI8,TESTED WITH A 24 INCH WIDE TEST DRAWER

This report serves to document the testing of the above sample to all applicabledrawer test paragraphs of ANSIIBHMA 156.9-2003, American national standardsfor cabinet hardware. Test procedures include a drawer slide stop test, drawerremoval and load placement test, drawer cycle testing and edge load application. Theremainder of this report will show how the drawer slides submitted for testing metthe requirements needed for conformance to the standard.

All procedures were performed with strict adherence to the ANSIIBHMA A156.9standard with one exception. The drawer test load was increased to 100 lbs, insteadof the 50 lb. Minimum requirement. All procedures were performed with this testload.

o the sample or samples submitted for testing and is not necessarily indicative of the quality or condition of apparently identical or similar products. As a mutual protection toclients, tire laboratories, this report is submitted and accepted for the exclusive use of the client to whom it is addressed, and upon that condition that it not be used, in whole or in part,in a.l1Y~advertising6t publicity matter without prior written authorization from these laboratories.

G:\~1YDoOillllentsulQitNITURE REPORTSIHardware resourceslFl008271-2, 303FUSPT18 BHMA.doc,

Page 2: INfIEGRITY TESTING LABORATORIES, - Nexcess CDNlghttp.31392.nexcesscdn.net/80DFAD/production/media/pdf/specs/303... · INfIEGRITY TESTING LABORATORIES, Hardware Resources 4319 Marlena

Hardware ResourcesLaboratory No. F1008271-2August 27,2010Page 2 of2

LABORATORY LABORATORY OBSERVATION A.,~SIIBHMAA156.9-03 TEST RESULTDETERMINA nON GRADE 1 REQUIREMENT

Drawer slide stop test The stop position provided 45. lbs., or ten The stop position shall provide at least ten times PASSBRMA section 4.11.2 times the operating force. the normal drawer operating force.

Drawer removal and The slides permitted complete drawer Drawer slides shall pemlit complete drawer PASS

load placement removal. Placement of loads did not cause removal. Load placement shall not cause theBRMA section 4.11.3 removal or partial removal from the drawer's drawer to be removed or partially removed from

suspended position when operated. its suspended position during drawer operation.

Drawer cycle life test Drawer operated for a total of 50,000 cycles Dra\ver shall be cycled 2/3 of the total travel for PASS

BRMA section 4.11.4 with a 100 lb. test load. Drawer opening 50,000 cycles with a 50 lb. test load. Drawerforce = 4.5 lbs. shall be completely operable after the

perfoffiwllceof the test.

Drawer edge load test There was no structural breakage or loss of There shall be no failure of the slides with an PASS

BRMA section 4.11.5 serviceability of the slide suspensions with an additional 75 lb. mass applied to the drawer edgeadditional 75 lb. edge load applied in the half-extended position.

During the execution of the testing program, the model 303FUSFT18 drawer slide suspension performedwell with no structural breakage or failure with the above load. This sample submitted for testing met all ofthe drawer slide test requirements and conforms to ANSIIBHMA 156.9-2003·for Grade 1 products.