1
3 Leak Detection Infrared (IR) Refrigerant Leak Detector Infrared (IR) Refrigerant Leak Detector Advantages Infrared sensor Made to last 10 years. 8-hour Battery Charge Work all day on one charge. Superior/Controlled Sensitivity Find CFC, HFC, HCFC blend leaks down to 0.1 oz./year. Three Sensitivity Levels Meets new SAE standards. Auto Re-calibration Senses change. Works in contaminated environments. Rugged / Ergonomic Ruggedized boot fits naturally in your hand. And more: n Audible/LED Bar Graph Indicators. n Sturdy, Non-conductive Probe n Peak Hold/Mute Buttons n Magnetic Hanger n Replaceable Water-blocking Filters n Weighs 14-oz. SRL2K7 Specifications Gases Measured CFC, HFC, HCFC and blends Sensing Element Infrared Response Time Less than 1/2 second to 1 second Sensitivity Levels HIGH 0.1 oz./year and higher MED 0.5 oz./year and higher LOW 1.0 oz./year and higher Accuracy Meets current SAE standards Calibration Automatic Warm Up 30 seconds Probe Length 15 inches. (24 inches with included 9 inch extension probes.) Battery Chargers Wall charger and vehicle charger included Battery 3.7VDC (nominal) rechargeable lithium ion battery Battery Life Approx. 8 hours if fully charged Test Tools HVACR Pros Trust Water Blocking Filter n Keeps water and other contaminants out n Easy filter replacement n Ten extra filters included n Five extra O-rings included State of the Art Infrared Sensor Power Solutions n 8 hour battery life to last the whole work day n Auto-off after 10 minutes n Rechargeable lithium ion battery n Wall charger included n Vehicle charger included SRL2K7 www.fieldpiece.com Test Tools HVACR Pros Trust Infrared Sensor n Long-life sensor made to last up to ten years n Controlled sensitivity down to 0.1 oz./yr. n Doesn't trigger on oil or moisture n Senses change. Works in contaminated environments Lithium Ion Battery n Delivers 8-hours of use per charge n Includes chargers for the truck and the shop n Works while charging n User replaceable What’s Included: n Advanced IR Refrigerant Leak Detector n 1 - 9-inch flex extension (RRE2) n 1 - 9-inch needle tip probe (RFE2) n 1 - vehicle charger (RCA2) n 1 - wall outlet charger (RWA2) n 10 - replacement filters, 5 - replacement o-rings (RFL2) Model: SRL2K7 H26-793 Infrared (IR) Refrigerant Leak Detector model SRL2K7 Comparing Fieldpiece Leak Detectors SRL2K7 (Infrared Sensor) SRL8 (Heated Diode Sensor) Stays very sensitive for the life of meter Requires sensor replacement to maintain sensitivity. Dependent on exposure Not affected by moisture or oil Can false trigger on moisture and oil Sensitivity is similar for different refrigerants More sensitive to some refrigerants than others Senses CHANGE in refrigerant concentration so it requires sweeping motion Senses absolute refrigerant concentration Bar graph indicates concentration Inherently handles background refrigerant without adjustment Zeroing (auto or manual) function resets level of triggering More expensive Less expensive © Fieldpiece Instruments, 2015 v21

Upload: others

Post on 14-Apr-2020

38 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Infrared (IR) Refrigerant Leak Detector · Infrared (IR) Refrigerant Leak Detector Infrared (IR) Refrigerant Leak Detector Advantages Infrared sensor Made to last 10 years. 8-hour

3Leak

Detection

Infrared (IR) Refrigerant Leak Detector

Infrared (IR)Refrigerant

Leak Detector

AdvantagesInfrared sensor

Made to last 10 years.

8-hour Battery ChargeWork all day on one charge.

Superior/Controlled SensitivityFind CFC, HFC, HCFC blend leaks down to 0.1 oz./year.

Three Sensitivity LevelsMeets new SAE standards.

Auto Re-calibrationSenses change. Works in contaminated environments.

Rugged / ErgonomicRuggedized boot fits naturally in your hand.

And more:n Audible/LED Bar Graph Indicators.

n Sturdy, Non-conductive Probe

n Peak Hold/Mute Buttons

n Magnetic Hanger

n Replaceable Water-blocking Filters

n Weighs 14-oz.

SRL2K7 SpecificationsGases Measured CFC, HFC, HCFC and blends

Sensing Element Infrared

Response Time Less than 1/2 second to 1 second

Sensitivity Levels HIGH 0.1 oz./year and higher

MED 0.5 oz./year and higher

LOW 1.0 oz./year and higher

Accuracy Meets current SAE standards

Calibration Automatic

Warm Up 30 seconds

Probe Length 15 inches. (24 inches with included 9 inch extension probes.)

Battery Chargers Wall charger and vehicle charger included

Battery 3.7VDC (nominal) rechargeable lithium ion battery

Battery Life Approx. 8 hours if fully chargedTest Tools HVACR Pros Trust

Water Blocking Filtern Keeps water and other

contaminants out

n Easy filter replacement

n Ten extra filters included

n Five extra O-rings included

State of theArt Infrared

Sensor

Power Solutionsn 8 hour battery life to last

the whole work dayn Auto-off after 10 minutesn Rechargeable lithium ion

batteryn Wall charger includedn Vehicle charger included

SRL2K7

www.fieldpiece.com

Test Tools HVACR Pros Trust

Infrared Sensorn Long-life sensor made to last up to ten years

n Controlled sensitivity down to 0.1 oz./yr.

n Doesn't trigger on oil or moisture

n Senses change. Works in contaminated environments

Lithium Ion Batteryn Delivers 8-hours of use per charge

n Includes chargers for the truck and the shop

n Works while charging

n User replaceable

What’s Included:n Advanced IR Refrigerant Leak Detector

n 1 - 9-inch flex extension (RRE2)

n 1 - 9-inch needle tip probe (RFE2)

n 1 - vehicle charger (RCA2)

n 1 - wall outlet charger (RWA2)

n 10 - replacement filters,

5 - replacement o-rings (RFL2)

Model: SRL2K7 H26-793

Infrared (IR) Refrigerant Leak Detector

model SRL2K7

Comparing Fieldpiece Leak DetectorsSRL2K7 (Infrared Sensor) SRL8 (Heated Diode Sensor)

Stays very sensitive for the life of meter Requires sensor replacement to maintain

sensitivity. Dependent on exposure

Not affected by moisture or oil Can false trigger on moisture and oil

Sensitivity is similar for different

refrigerants

More sensitive to some refrigerants than

others

Senses CHANGE in refrigerant

concentration so it requires sweeping

motion

Senses absolute refrigerant concentration

Bar graph indicates concentration

Inherently handles background refrigerant

without adjustment

Zeroing (auto or manual) function resets

level of triggering

More expensive Less expensive

© Fieldpiece Instruments, 2015 v21