INFRARED SPECTROSCOPY: A POTENTIAL QUALITY ASSURANCE METHOD FOR COMPOSITE BONDING SURFACE PREPARATION Ashley C. Tracey, Brian D. Flinn University of Washington Materials Science and Engineering Department 302 Roberts Hall, Box 352120 Seattle, WA 98195-2120 ABSTRACT The purpose of this research is to evaluate Fourier transform infrared spectroscopy measurement methods (FTIR) as a potential technique to monitor surface preparation processes for adhesive bonding of composite substrates. The recent availability of handheld FTIR instruments enables application of infrared spectroscopy in manufacturing or repair environments. This motivates research to understand the capabilities of FTIR as a potential technique for surface preparation inspection. Infrared spectroscopy can be used to identify chemical bonds on a composite surface prepared for secondary bonding. This information can help understand one requirement of adhesion: the formation of primary chemical bonds between the adherend and adhesive as well as the identification of contaminants. Mid-infrared spectroscopy measurements are made using a bench-top infrared spectrometer (Bruker Vertex 70) and a handheld infrared spectrometer (Agilent Technologies Exoscan). The bench-top FTIR is configured with a single-bounce diamond crystal attenuated total reflectance (DATR) sampling interface. The handheld FTIR uses a diffuse reflectance sampling interface. The materials examined are 177 °C cure carbon fiber reinforced epoxy laminates prepared with various surface preparation methods, including peel ply preparation and manual abrasion. Infrared spectroscopy measurements characterized surfaces with various surface preparations and contaminants. The sensitivity of both devices will be discussed and referenced to surface preparation and bond quality data. 1. INTRODUCTION With the advent of the Boeing 787 and Airbus A350, adhesive bonds are now being used extensively for large aerospace structures. In comparison to mechanical fasteners, bonding reduces weight, eliminates stress concentrations and eliminates the need for sealants to protect against environmental damage. The purpose of this research was to evaluate infrared spectroscopy techniques as a possible inspection method for pre-bond surface preparations. The most important step in the formation of adhesive bonds is surface preparation to create chemically active surfaces that maximize bond strength and to prevent or remove contaminants that can adversely affect bonding. Adhesive bonding predominantly depends on the formation of primary chemical bonds and less on mechanical factors, thus surfaces must be properly prepared for formation of strong adhesive bonds [1, 2]. The surface preparation methods of focus for this research were peel ply and manual abrasion with use of a random orbital sander. A peel ply is a polymer fabric, such as polyester or nylon. It

Upload: nguyenduong

Post on 21-Dec-2016

220 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: infrared spectroscopy: a potential quality assurance method for

INFRARED SPECTROSCOPY: A POTENTIAL QUALITY ASSURANCE METHOD FOR COMPOSITE BONDING

SURFACE PREPARATION

Ashley C. Tracey, Brian D. Flinn University of Washington

Materials Science and Engineering Department 302 Roberts Hall, Box 352120

Seattle, WA 98195-2120

ABSTRACT The purpose of this research is to evaluate Fourier transform infrared spectroscopy measurement methods (FTIR) as a potential technique to monitor surface preparation processes for adhesive bonding of composite substrates. The recent availability of handheld FTIR instruments enables application of infrared spectroscopy in manufacturing or repair environments. This motivates research to understand the capabilities of FTIR as a potential technique for surface preparation inspection. Infrared spectroscopy can be used to identify chemical bonds on a composite surface prepared for secondary bonding. This information can help understand one requirement of adhesion: the formation of primary chemical bonds between the adherend and adhesive as well as the identification of contaminants. Mid-infrared spectroscopy measurements are made using a bench-top infrared spectrometer (Bruker Vertex 70) and a handheld infrared spectrometer (Agilent Technologies Exoscan). The bench-top FTIR is configured with a single-bounce diamond crystal attenuated total reflectance (DATR) sampling interface. The handheld FTIR uses a diffuse reflectance sampling interface. The materials examined are 177 °C cure carbon fiber reinforced epoxy laminates prepared with various surface preparation methods, including peel ply preparation and manual abrasion. Infrared spectroscopy measurements characterized surfaces with various surface preparations and contaminants. The sensitivity of both devices will be discussed and referenced to surface preparation and bond quality data.

1. INTRODUCTION With the advent of the Boeing 787 and Airbus A350, adhesive bonds are now being used extensively for large aerospace structures. In comparison to mechanical fasteners, bonding reduces weight, eliminates stress concentrations and eliminates the need for sealants to protect against environmental damage.

The purpose of this research was to evaluate infrared spectroscopy techniques as a possible inspection method for pre-bond surface preparations. The most important step in the formation of adhesive bonds is surface preparation to create chemically active surfaces that maximize bond strength and to prevent or remove contaminants that can adversely affect bonding. Adhesive bonding predominantly depends on the formation of primary chemical bonds and less on mechanical factors, thus surfaces must be properly prepared for formation of strong adhesive bonds [1, 2]. The surface preparation methods of focus for this research were peel ply and manual abrasion with use of a random orbital sander. A peel ply is a polymer fabric, such as polyester or nylon. It

Page 2: infrared spectroscopy: a potential quality assurance method for

is the last layer applied to a composite part before cure and is removed directly before bonding. Figure 1 displays the removal of a peel ply and the resulting surface. Infrared spectroscopy techniques examined used the Bruker Vertex 70, a desktop instrument, and the Agilent Technologies Exoscan, a handheld device. The Vertex 70, configured with attenuated total reflectance (ATR), was used to measure the surface chemistry of composite substrates for comparison with the Exoscan, configured with diffuse reflectance. Surface characterization is important in the aerospace industry, where adhesive bonding of composites is desired, because it can aide in the understanding of adhesion. This paper will discuss processing conditions that can affect infrared spectroscopy measurements: peel ply type, peel ply contamination and manual abrasion of peel ply surfaces.

Figure 1: Removal of peel ply from a carbon fiber reinforced epoxy composite (CFRP).

1.1 Peel Ply Type Traditional peel ply surface preparation is material system (prepreg and adhesive) specific [3, 4]. Certain peel ply, composite and adhesive systems result in strong bonds whereas others result in weak bonds. For example, previous research shows that polyester peel ply prepared 177°C cure CFRP shows cohesive failure and a GIC = 812±35 J/m2 when bonded with MB1515-3 adhesive [5]. However, when this same CFRP material is prepared with nylon peel ply and bonded with MB1515-3, adhesion failure is observed with resulting GIC = 122±15 J/m2 [5]. Similarly, when this CFRP is prepared with Super Release Blue (SRB) release ply (polyester peel ply coated with siloxane) and bonded with MB1515-3, adhesion failure and GIC < 94 J/m2 are observed [5]. Table 1 shows the failure modes for the combinations of substrate, surface preparation and adhesive discussed [5]. The mode I strain energy release rates (GIC) and failure modes were determined using Mode I Double Cantilever Beam (DCB) testing [5]. Because different peel ply fabrics may appear visually very similar, we need to be able to detect the peel ply preparation material prior to bonding. One aspect of this research examined common peel ply materials (polyester and nylon) used for bonding, as well as a release ply (SRB) known to cause poor adhesion. Table 1: DCB fracture surfaces of peel ply surfaces bonded with MB1515-3 adhesive [5].

Polyester Prepared Nylon Prepared SRB Prepared

Failure Mode Cohesive Adhesion Adhesion

GIC 812±35 J/m2 122±15 J/m2 < 94 J/m2

11

Table 2 Fracture surfaces of tested laminates (Sample Width = 12.7 mm)

Polyester Prepared Nylon Prepared SRB Prepared

AF555

Failure Mode Cohesive Cohesive & Interlaminar Adhesion

MB1515-3

Failure Mode Cohesive Adhesion Adhesion

The measure of bond quality for our purposes is the critical strain energy release rate of the

bonded laminate, determined by Mode I DCB Testing. As can be seen in

Figure 8, surfaces prepared with SRB displayed consistently poor bonding. Samples prepared

with polyester peel ply had the best consistent bond quality. A dramatic change in fracture

energy was observed when nylon-prepared surfaces were bonded with MB1515-3 rather than

AF555. The fracture mode also changed from cohesive (AF555) to adhesion (MB1515-3) as

shown in Table 2. The mode of failure (cohesive/interlaminar) seen in samples prepared with

polyester peel ply and nylon peel ply bonded with AF555 is more desirable than the adhesion

(interfacial) failure seen in the other samples.

Figure 8 Mode I strain energy release rate of laminates bonded with AF 555 (A) or MB 1515-3

(B)

11

Table 2 Fracture surfaces of tested laminates (Sample Width = 12.7 mm)

Polyester Prepared Nylon Prepared SRB Prepared

AF555

Failure Mode Cohesive Cohesive & Interlaminar Adhesion

MB1515-3

Failure Mode Cohesive Adhesion Adhesion

The measure of bond quality for our purposes is the critical strain energy release rate of the

bonded laminate, determined by Mode I DCB Testing. As can be seen in

Figure 8, surfaces prepared with SRB displayed consistently poor bonding. Samples prepared

with polyester peel ply had the best consistent bond quality. A dramatic change in fracture

energy was observed when nylon-prepared surfaces were bonded with MB1515-3 rather than

AF555. The fracture mode also changed from cohesive (AF555) to adhesion (MB1515-3) as

shown in Table 2. The mode of failure (cohesive/interlaminar) seen in samples prepared with

polyester peel ply and nylon peel ply bonded with AF555 is more desirable than the adhesion

(interfacial) failure seen in the other samples.

Figure 8 Mode I strain energy release rate of laminates bonded with AF 555 (A) or MB 1515-3

(B)

11

Table 2 Fracture surfaces of tested laminates (Sample Width = 12.7 mm)

Polyester Prepared Nylon Prepared SRB Prepared

AF555

Failure Mode Cohesive Cohesive & Interlaminar Adhesion

MB1515-3

Failure Mode Cohesive Adhesion Adhesion

The measure of bond quality for our purposes is the critical strain energy release rate of the

bonded laminate, determined by Mode I DCB Testing. As can be seen in

Figure 8, surfaces prepared with SRB displayed consistently poor bonding. Samples prepared

with polyester peel ply had the best consistent bond quality. A dramatic change in fracture

energy was observed when nylon-prepared surfaces were bonded with MB1515-3 rather than

AF555. The fracture mode also changed from cohesive (AF555) to adhesion (MB1515-3) as

shown in Table 2. The mode of failure (cohesive/interlaminar) seen in samples prepared with

polyester peel ply and nylon peel ply bonded with AF555 is more desirable than the adhesion

(interfacial) failure seen in the other samples.

Figure 8 Mode I strain energy release rate of laminates bonded with AF 555 (A) or MB 1515-3

(B)

Page 3: infrared spectroscopy: a potential quality assurance method for

1.2 Peel Ply Contamination Surface contamination is detrimental to bonding because the adhesive is in contact with the surface contaminant rather than the surface itself. This creates an unreliable bond that can fracture at loads well below design specifications. Because contamination cannot be completely eliminated in all composite fabrication environments, we need to be able to detect it prior to bonding. This research examined peel plies that were intentionally contaminated with siloxane, a common processing agent that has been shown to degrade bond quality for 177°C cure CFRP bonded with MB1515-3 at mixed target levels as low as 1% siloxane contamination levels [6]. Refer to section 2.1.2 for definition of contamination levels. This is supported by figure 2, which shows Backing Rapid Adhesion Test (B-RAT) results, where the red arrows denote a contaminated bond [6].

Figure 2: B-RAT results showing bond quality is degraded of CFRP substrates bonded with MB1515-3 and contaminated with peel ply contamination levels at 1% siloxane and greater [6].

This research also showed a FTIR-ATR residue test could detect contamination on a CFRP surface prepared with 0.5% siloxane contaminated polyester peel ply [6]. The ATR sampling technique relies on transfer of the silicone from the material surface to the ATR crystal. Infrared spectra in Figure 3 were collected by sampling the CFRP surfaces. Figure 3 zooms in on the spectral region containing characteristic silicone peaks at 1260, 1100, 1022 and 800 cm-1. Although siloxane peaks were not much above the noise level, they are clearly visible for 0.5%, 1% and 2% siloxane contamination, as shown in figure 3 [6]. Thus, a FTIR-ATR residue test of the CFRP surface can detect siloxane contamination levels below which bond quality is affected.

Figure 3: ATR residue test spectra for 0.5%, 1% and 2% contamination levels [6].

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

EA9657K; 0.08psf AF555M; 0.05psf MB1515-3M 0.05psf

Pe

el

Str

en

gth

(N

-m/2

5.4

mm

wid

th)

0%

0.0001%

0.001%

0.01%

0.05%

0.10%

0.20%

0.30%

0.40%

0.50%

1%

2%

Solid Green: Cohesive Capability

Dashed Blue: Carbon Delamination

Red Arrow: Contaminated Bond

!"#$%&'!()!*+,-.!&'/%01/)!

3.4.3 DCB Results

234'!5!6&781%&'!'9'&$:;!<5=;!>7/!?'7/%&'!7883&4#[email protected]!ABBC()!!A=*!1'/1/!D74!7!03//!36!

74D'/#39!7/!?7&E'4!F:!67#0%&'/!71!1D'!G''0!G0:!#91'&678'!71!/#03H79'!83917?#971#39!0'I'0/!36!CJ!

63&!700!36! 1D'!74D'/#I'/!'I70%71'4)!-039$!>#1D! 1D'! 67#0%&'!?34'!71! 1D'!G''0!G0:! #91'&678';! 1D'&'!

>'&'!/D7&G!4'80#9'/!#9!<5=!71!1D'!CJ!/#03H79'!8394#1#39)!"3&!39'!74D'/#I';!K2!-"BBB;!1D'&'!>7/!

G7&1#70!03//!36!74D'/#39!71!LJ!/#03H79')!-//38#71'4!>#1D!1D#/!>7/!7!?34'/1!4'80#9'!#9!<5=)!!

!

"3&! 1D'! 83?F#971#39/! 36! /%F/1&71'/! 794! 74D'/#I'/! 'I70%71'4;! 67#0%&'! ?34'/! 1D71! >'&'! G%&'0:!

83D'/#I'!>#1D#9!1D'!74D'/#I'!>'&'!931!'983%91'&'4!63&!79:!36!1D'!1'/1/)!,71D'&!1D'!67#0%&'!?34'!

>7/!7!83?F#971#39!36!83D'/#I'!>#1D#9! 1D'!74D'/#I'!794! #91'&07?#97&!>#1D#9! 1D'! /%F/1&71')!.D#/!

1'94'98:!13>7&4!#91'&07?#97&!67#0%&'!>#1D!1D'!A=*!1'/1!?%1'/!1D'!I70%'!36! 1D'!M%791#171#I'!1'/1!

&'/%01/;!7/!1D'!D#$D'&!13%$D9'//!36!1D'!74D'/#I'!#/!4#0%1'4!F:!1D'!03>'&!13%$D9'//!36!1D'!07?#971')!

*7/'4!39!G&'I#3%/!A=*!&'/%01/! 63&! 1D'!$#I'9!74D'/#I'/!71!*3'#9$!>D'&'! 1D'!67#0%&'!?34'!>7/!

9'7&0:! LNNJ! 83D'/#I'! #9! 1D'! 74D'/#I';! 7! $&''9! 0#9'! >7/! 4&7>9! 39! "#$%&'! O! 1D71! 4'931'/! 1D'!

83D'/#I'! 87G7F#0#1:! 36! 1D'! $#I'9! 74D'/#I')! "#$%&'! O! /D3>/! 1D71! 1D'! 781%70! A=*! I70%'/! 6700!

F'1>''9! 1D'! 83D'/#I'! 87G7F#0#1:! 36! 1D'! 74D'/#I'! P/30#4! 0#9'Q! 794! 1D'! 87&F39! 4'07?#971#39!

1D&'/D304)!!!

!

-0.0001

0.0001

0.0003

0.0005

65075085095010501150125013501450

Wavenumbers

Ab

so

rba

nc

e

2% CFRP 1% CFRP 0.5% CFRP

!"#$%&'!()!*#+,-./!012!&'3#/%'!34'56&+)!!!17'!57+&+56'&#36#5!3#8#5-.'!9+./3!+6!:;(<=!::<<=!:<;;!

+./!><<!?+@'.%,9'&3!+&'!9+&'8A!+9-@'!67'!.-#3'!8'@'8)!

3.3.4 Results from XPS Analysis

BCD!?+3!4'&E-&,'/!6-!/'6'&,#.'!'8','.6+8!5-,4-3#6#-.!-E!67'!F"2C!3%&E+5')!!"#$%&'!G!#3!+!48-6!

-E!67'!4'&5'.6!3#8#5-.!@#+!BCD!+$+#.36!67'!4'&5'.6!3#8-H+.'!#.!67'!4''8!48A)!!17'!48-6!#3!8#.'+&!E-&!

67'!/+6+!4-#.63! E&-,!<):! 6-!:)<! 4'&5'.6! 3#8#5-.! #.58%3#@'8A)! !I-?'@'&=! 67'!;)<!4'&5'.6! 3#8-H+.'!

4''8!48A!?+3!.-6!/'6'&,#.'/!6-!7+@'!3#$.#E#5+.68A!,-&'!3#8#5-.!67+.!67'!:)<!4'&5'.6!3#8-H+.'!4''8!

48A)! ! 0! 4-33#98'! 'H48+.+6#-.! E-&! 67#3! 6&'./! #3! 67+6! :)<! 4'&5'.6! 3#8-H+.'! 5-.6+,#.+6#-.! ?+3!

3%EE#5#'.6! 6-! 3+6%&+6'! 67'! 3%&E+5'!-E! 67'! 5+&9-.! E#9'&! 5-,4-3#6'!?#67! 3#8#5-.')! !17'! +//#6#-.!-E!

3#8-H+.'! #.! 'H5'33! -E! :)<! 4'&5'.6! ,+A! #.E8%'.5'! 67'! 3#8#5-.! 5-.6'.6! -E! 67'! F"2C! +6! $&'+6'&!

/#36+.5'3!E&-,!67'!3%&E+5'!67+.!+&'!+55'33#98'!9A!BCD)!

0.00

0.50

1.00

1.50

2.00

2.50

3.00

3.50

4.00

4.50

5.00

0.00% 0.50% 1.00% 1.50% 2.00% 2.50%

Siloxane % on peel ply

%S

i o

n lam

inate

!"#$%&'!G)!C8-6!-E!J8','.6+8!D#8#5-.!@#+!BCD!@'&3%3!C'&5'.6!3#8-H+.'!-.!67'!C''8!C8A!

Page 4: infrared spectroscopy: a potential quality assurance method for

The current research examined CFRP surfaces prepared with the same contaminated peel plies as reference 6 with handheld diffuse-reflectance FTIR (Exoscan) to determine if it can be used as a quality assurance technique for siloxane contamination.

1.3 Manual Abrasion to Remove Peel Ply Texture Surface roughening by means of abrasion to expose a fresh surface and remove contaminants is a surface preparation method for composites bonding [7,8]. Previous research has shown that abrasion (grit blasting and sanding) can remove mold release agents that can be detrimental to bonding, changing the surface chemistry and surface energy [7]. For grit blasted specimens, the grit material and grit size also has an affect on surface chemistry and energy [7]. It has also been shown that 177°C cure composites prepared with polyester peel ply and bonded with paste adhesive do not form reliable bonds, failing in adhesion using the DCB test [9]. Surface abrasion can be used to remove peel ply texture from the composite resulting in cohesive failure when bonded with paste adhesives [9]. It is thus important that the peel ply surface be removed before composites should be bonded with paste adhesives. Surface abrasion can be achieved by techniques such as manual abrasion or grit blasting. Often times, composites are prepared with peel ply to keep contaminants from settling onto the surface prior to bonding. Directly before bonding, the peel ply is removed and the surface is abraded to remove the peel ply surface. CFRP surfaces were prepared with nylon and polyester peel ply and abraded to various levels of surface removal. These surfaces were measured with FTIR to determine if FTIR can detect differences between the various levels of sanding. Such differences could include chemical differences due to peel ply or contamination removal as well as physical differences due to roughness.

2. EXPERIMENTATION 2.1 Specimen Preparation 2.1.1 Peel Ply Type The effect of peel ply type on surface chemistry was examined using 4-ply panels of carbon fiber reinforced epoxy prepreg composite (Toray 3900/T800 unidirectional tape) surfaces prepared with various peel plies. These included a polyester peel ply (Precision Fabric Group 60001), a nylon peel ply (Precision Fabric Group 52006) and a siloxane coated polyester peel ply (Precision Fabric Group Super Release Blue). These panels were prepared by laying up [0/90]s CFRP laminates, vacuum bagging the panels and curing them in an autoclave. The autoclave cure cycle for the specimens were as follows:

1. Heat to 57.2°C (135°F) at a rate of 1.1°C/min (2°F/min), increase pressure to 0.6MPa (89psi) at a rate of 0.1MPa/min (20psi/min), soak for 0 min

2. Heat to 177°C (350°F) at a rate of 5.6°C/min (10°F/min), maintain pressure of 0.6MPa (89psi), soak at 177°C and 0.6MPa for 120 min (2 hr)

3. Cool to 10°C (50°F) at a rate of 5.6°C/min (10°F/min), maintain pressure of 0.6MPa (89psi), soak for 0 min

4. Decrease pressure to 0Mpa (0psi) at a rate of 0.1MPa/min (20psi/min), while maintaining a temperature of 10°C (50°F), soak 0 min

Page 5: infrared spectroscopy: a potential quality assurance method for

2.1.2 Peel Ply Contamination Peel ply contamination was achieved by preparing solutions with predetermined weight percent of siloxane concentrations, defined as grams mixed solids per 100 grams of solution, (0% (control), 0.1%, 0.2%, 0.3%, 0.4%, 0.5%, 1% and 2%) and applying these solutions to Precision Fabrics 60001 polyester peel ply [6]. The processing and characterization of the siloxane contaminated peel plies are described by VanVoast, et. al in reference [6]. Panels with 1% and 2% siloxane contamination were provided by Boeing. Panels with 0.1%-0.5% siloxane contaminated peel plies were made from 4-ply CFRP prepreg (Toray 3900/T800 unidirectional tape) with a [0/90]s layup. These panels were autoclave cured as described in section 2.1.1.

2.1.3 Manual Abrasion to Remove Peel Ply Texture The effect of Manual abrasion on surface chemistry was examined using 4-ply panels of carbon fiber reinforced epoxy prepreg composite (Toray 3900/T800 unidirectional tape) prepared with nylon (PFG 52006) and polyester (PFG 60001) peel ply. These panels were prepared by laying up [0/90]s CFRP laminates, vacuum bagging the panels and curing them in an autoclave. The autoclave cure cycle is described in section 2.1.1. Manual abrasion was performed with a random orbital sander, using 120 grit ceramic abrasive sanding discs. Three levels of abrasion were studied for each peel ply surface preparation. The first two levels were partial abrasion with peel ply texture still evident and the third level abraded far enough into the surface to remove all peel ply texture. After abrasion, the dust was removed from the samples using a vacuum. No solvent was used to clean the surface to avoid adding other chemical species to the surface. This was done to understand how abrasion affects the surface chemistry before adding other chemicals. Representative images of each level of sanding for nylon and polyester peel ply surface preparation are shown in table 2. Table 2: SEM micrographs of nylon prepared surface and polyester prepared surface with various levels of abrasion after peel ply removal.

Peel Ply Texture, No Abrasion

> 75% Peel Ply Surface Evident

< 50% Peel Ply Surface Evident

No Peel Ply Surface Evident

Nylon Prepared

Polyester Prepared

2.2 Fourier Transform Infrared Spectroscopy Measurements FTIR measurements were performed using a Bruker Vertex 70 FTIR bench-top instrument configured with a DATR sampling interface and an Agilent Technologies Exoscan handheld

Page 6: infrared spectroscopy: a potential quality assurance method for

portable FTIR configured with a diffuse reflectance sampling interface. Figure 4 shows pictures of both instruments.

(a) (b) Figure 4: (a) Agilent Technologies Exoscan FTIR [10] and (b) Bruker Vertex 70 FTIR [11] An SOC400 bench-top FTIR (by Surface Optics Corporation) configured with an integrating sphere sample interface was used to determine siloxane contamination levels via hexane extraction of the surfaces prepared with siloxane contaminated peel plies. The SOC400 was not used to examine the surfaces directly.

2.2.1 Bruker Vertex 70 DATR FTIR After the composite panels were cured, they were removed from the autoclave and cut into test strips, approximately 5 cm (2 in) by 10 cm (4 in) in dimensions. Immediately before testing peel ply prepared specimens, the peel ply was removed. Manually abraded specimens were prepared 2 days before testing and were kept in covered petri dishes and stored under vacuum to keep any contaminants from settling on the surface. A single bounce diamond ATR was used to collect spectra in the mid-infrared region (MIR: 4000 cm-1 to 400 cm-1) from 16 scans with 4 cm-1 resolution for background and specimen spectra. A background spectrum of air was collected before each run. The specimen was then placed onto the DATR crystal and the sample spectrum was collected. A pressure clamp was used to ensure good contact between the crystal and the sample, always applying the maximum pressure (30,000 psi). A pressure clamp is necessary because ATR requires intimate contact between the crystal and the sample. The background spectra were ratioed to the specimen spectra for analysis. Figure 5 shows an infrared beam path for the DATR.

Figure 5: An infrared beam path for a single bounce DATR

2.2.2 Agilent Technologies Exoscan Diffuse Reflectance FTIR An Exoscan FTIR was also used to collect spectra from the prepared surfaces for comparison with DATR spectra. Immediately before testing samples prepared with peel ply, the peel ply was removed. Manually abraded specimens were prepared 2 days before testing and were kept in covered petri dishes and stored under vacuum to keep any contaminants from settling on the surface. The Exoscan, which was configured for diffuse reflectance, used one background spectrum for a series of specimens. Note that this is different from DATR data collection where a

Page 7: infrared spectroscopy: a potential quality assurance method for

background spectrum was collected before each sample spectrum. The background was then ratioed to the specimen spectra. Data collected was 90 scans with 16 cm-1 resolution in the MIR data range (650-4000 cm-1). Note a pressure clamp was not used, as diffuse reflectance sampling does not use a crystal that the specimen must be in contact with. Figure 6 shows the beam path for diffuse reflectance.

Figure 6: An infrared beam path for diffuse reflectance.

2.2.3 Surface Optics Corporation (SOC) FTIR with Vertical Integrating Sphere for Analysis of Hexane Extraction of Siloxane Contaminated Specimens

The SOC400 FTIR was used as a reference method to determine how much contamination transferred to the composite surfaces prepared with siloxane contaminated peel plies. This technique was chosen because it has been proven capable of detecting low concentrations due to the integrating sphere. Samples with contamination levels ranging from 0.1%-2% were examined as well as a control surface, referred to as 0% (prepared with polyester peel ply) and a sample prepared with SRB (polyester peel ply heavily coated with siloxane). One 2” x 2” test specimen was cut from each sample for hexane extraction. Clean vials (one for each sample) were filled with 5mL hexane used to swab each surface. Immediately before testing, peel ply was removed and using a clean glass swab, each 2”x2” surface was wiped four times. Between each wiping, the glass swab was submerged in the hexane to extract any siloxane removed from the surface. The hexane containing contamination from the surfaces was filtered using a syringe attached to a PALL Life Sciences Acrodisc CR 25mm Syringe Filter with 0.45µm PTFE Membrane. During the swabbing, glass fibers from the glass swab broke off into the vials. The purpose of filtering was to remove these fibers, which could influence the spectra. All hexane solutions were filtered through the same syringe. The syringe was cleaned with hexane between each sample and samples were filtered from lowest to highest siloxane contamination. The filtered solutions were placed in individual gold coated half-sphere cups that were confirmed to be clean from contaminants prior to use. The hexane was evaporated leaving behind the residue removed from the surfaces in the cups. Data collection was 64 scans with 8 cm-1 resolution in the MIR data range (4000-650 cm-1) for background and specimen spectra. One initial background of an empty cup was collected.

2.3 Multivariate Analysis of FTIR Spectra The Unscrambler X software package was used for multivariate analysis of FTIR spectra. Multivariate analysis is a powerful tool for the examination of chemical spectra because it can

Page 8: infrared spectroscopy: a potential quality assurance method for

help identify differences in peak locations and peak intensities that are not otherwise obvious. Principal component analysis (PCA) was used to determine if differences existed between the spectra. Generally, 2 principal components were used. Some spectra required preprocessing before PCA for a difference to be observed. Preprocessing used was a Savitsky-Golay first derivative with 5 smoothing points fit to a 2nd order polynomial. This derivative was used to amplify differences between spectra by amplifying changes in slope of the spectral peaks, while reducing effects of baseline offsets. Smoothing points were used to reduce the influence of noise.

3. RESULTS AND DISCUSSION 3.1 Peel Ply Type 3.1.1 Bruker Vertex 70 DATR FTIR Results Figure 7 shows representative spectra for polyester, nylon and SRB peel plies, with arrows pointing to peaks of interest with table 3 showing which peak can be attributed to what peel ply material. Since these surface preparation materials are clearly chemically different, a difference in CFRP surfaces prepared with each of these materials could be observed.

Figure 7: DATR-MIR-FTIR spectra for polyester, nylon and SRB peel plies, with arrows indicating peaks of interest. Table 3: IR peaks identified by wave number peak location and peel ply material [6,12,13,14].

Peak Peak Location (cm-1) Peel Ply Material Polyester Peak: C=O 1730 Polyester, SRB Amide II Band: C-N stretch + CO-N-H bend 1530 Nylon CH2 wagging mode of trans conformer of glycol moiety

1340 Polyester

Silicone peaks 1260, 1100, 1022, 800 SRB Trans configuration of ethylene glycol unit 975 Polyester Amide IV Band: C-CO stretch 930 Nylon

Page 9: infrared spectroscopy: a potential quality assurance method for

Gauche configuration of –OCH2CH2- group 896 Polyester Benzene ring 795 Polyester Amide V Band: N-H out-of-plane bend 680 Nylon Figure 8 shows spectra for polyester, nylon and SRB prepared CFRP surfaces. Other than the potential silicone band observed at 1260 cm-1 for the SRB prepared surface, no differences were visually observed between spectra for different CFRP peel ply preparations. PCA analysis of the fingerprint region of 5-6 spectra for each surface preparation showed no difference between polyester, nylon and SRB surface preparations.

Figure 8: DATR-MIR-FTIR spectra for polyester, nylon and SRB prepared surfaces.

3.1.2 Agilent Technologies Exoscan Diffuse Reflectance FTIR Results Shown in figure 9 are spectra collected using diffuse reflectance with an Exoscan FTIR. The black box denotes the range (fingerprint region) over which multivariate analysis was used to identify differences between spectra, as all spectra showed CH and OH stretches.

Silicone band at 1260 cm

-1 ?

Polyester prepared

SRB prepared

Nylon prepared

Page 10: infrared spectroscopy: a potential quality assurance method for

Figure 9: Range analyzed with multivariate analysis. PCA of two principal components with preprocessing identified differences between spectra. Preprocessing was a Savitsky-Golay first derivative with five smoothing points fit to a 2nd order polynomial. The scores from this analysis are shown in figure 10. A scores plot is a multivariate tool that shows differences between samples, where PC-1 shows the greatest source of variation between all sample spectra and PC-2 shows the second greatest source of variation between sample spectra. This shows that PCA analysis was successful in identifying differences between peel ply surface preparations, as it separated them all on the first principal component (PC-1).

Figure 10: PCA analysis results of peel ply surface preparation detected by diffuse reflectance. These specimens were used as calibration samples for a partial least squares (PLS) regression method for the Exoscan. PLS is a multivariate technique that relates variation in spectra to specific values or properties. The test method developed using PLS correctly identified polyester, nylon and SRB prepared specimens. Thus, the Exoscan, configured with a diffuse reflectance sampling interface, has a potential application in the bonding process as a quality assurance method to test for peel ply preparation.

1=Nylon prep 2=SRB prep

3=Polyester prep

1=Nylon prep 2=SRB prep

3=Polyester prep

Page 11: infrared spectroscopy: a potential quality assurance method for

3.2 Peel Ply Contamination 3.2.1 Hexane Extraction Results Silicone materials have characteristic IR peaks at 800, 1022, 1100 and 1260 cm-1. All spectra showed these four peaks. The silicone peak at 1260 cm-1 was used to determine the amount of siloxane extracted from each of the surfaces. Figure 11 shows the fingerprint region of the spectra resulting from hexane extraction with a zoomed-in view of the peak at 1260 cm-1 used for quantification of the amount of siloxane contamination transferred to the surface. Also shown is the hexane only (“Hexane blank”) extraction, which showed a small peak at 1260 cm-1. Figure 12 shows a plot of the peak areas for each contamination level, showing a general trend of an increase in surface contamination with an increase in peel ply contamination, as peak area is directly proportional to amount of siloxane contamination [6].

Figure 11: FTIR spectra of hexane extracted residue with gray box highlighting analysis peaks at 1260 cm-1.

Figure 12: Plot of 1260 cm-1 peak areas as a function of peel ply contamination.

3.2.2 Agilent Technologies Exoscan Diffuse Reflectance FTIR Results Initial PCA analysis with no preprocessing of siloxane contaminated samples showed clusters of each sample type without any one sample or spectra as an outlier. This is displayed in figure 13. From this analysis, it may be possible to detect the presence of siloxane contamination, as all contaminated specimens are separated from the 0% (control) specimen. However, further

Page 12: infrared spectroscopy: a potential quality assurance method for

research is necessary determine if a detection limit exists. Observed separation of samples may be attributed to potential processing differences between 1% and 2% (manufactured at Boeing) and the rest of the samples (manufactured at University of Washington), slight color differences between the samples affecting the signal or other unknown experimental factors.

Figure 13: PCA analysis of siloxane contaminated surfaces.

3.3 Manual Abrasion to Remove Peel Ply Texture 3.3.1 Bruker Vertex 70 DATR FTIR Results DATR spectra collected from polyester peel ply prepared surfaces with various levels of abrasion were examined with PCA from 1900-600cm-1. These levels varied from no abrasion (polyester peel ply surface) to partial abrasion with peel ply texture still present to complete removal of peel ply texture. Initial PCA analysis of manually abraded surfaces originally prepared with polyester peel ply display some difference between abrasion conditions, as shown in figure 14. PCA with two principal components and preprocessing were used to identify differences between spectra. Preprocessing was a Savitsky-Golay first derivative five smoothing points fit to a 2nd order polynomial. No difference was observed between conditions 0 and 1 or between conditions 2 and 3, as the spacing between specimens within each group was the same as the spacing between the individual groups. This means that PCA identified conditions 0 and 1 as the same and conditions 2 and 3 as the same but could identify 0 and 1 separate from 2 and 3.

Figure 14: Scores plot showing differences between DATR spectra of non-abraded (peel ply surface) and abraded surfaces.

0=polyester peel ply surface

1= >75% peel ply surface evident 2= <50% peel ply surface evident

3=no peel ply surface evident

Page 13: infrared spectroscopy: a potential quality assurance method for

Nylon peel ply prepared surfaces were also abraded to various levels of peel ply texture removal ranging from no abrasion (nylon peel ply surface) to partial abrasion with peel ply texture still present to complete removal of peel ply texture. Initial PCA analysis without preprocessing of the fingerprint region (1800-600 cm-1) of manually abraded surfaces originally prepared with nylon peel ply showed even less of a difference between conditions than PCA analysis of surfaces originally prepared with polyester. Though there were separate groups for each condition (as also apparent in figure 14), the spacing between the groups and individual specimens within a group was about the same, suggesting that PCA did not differentiate between the abrasion conditions.

3.3.2 Agilent Technologies Exoscan Diffuse Reflectance FTIR Results Diffuse reflectance spectra collected from polyester peel ply prepared surfaces with various levels of abrasion were examined with PCA from 2000-650cm-1. These levels varied from no abrasion (polyester peel ply surface) to partial abrasion with peel ply texture still present to complete removal of peel ply texture. Initial PCA analysis without preprocessing of manually abraded surfaces originally prepared with polyester peel ply display a difference between the conditions along PC-1, as shown in figure 15. No difference, however, was observed between the peel ply surface condition (0) and >75% peel ply surface evident condition (1), as the spacing between specimens in a group is about the same as the spacing between the groups. This could have been due to the low level of abrasion of the sample, as observed previously in table 2.

Figure 15: Scores plot showing differences between diffuse spectra of non-abraded (peel ply surface) and abraded surfaces. Nylon peel ply prepared surfaces were also abraded to various levels of peel ply texture removal ranging from no abrasion (nylon peel ply surface) to partial abrasion with peel ply texture still present to complete removal of peel ply texture. Initial PCA without preprocessing of the fingerprint region (2000-650 cm-1) of manually abraded surfaces originally prepared with nylon peel ply showed a difference between properly (3) and improperly (0, 1, 2) abraded conditions. All specimens were grouped into clusters, with separation of specimen groups along PC-1. There was no separation, however, observed for the partial abrasion conditions (1&2). This could have been due to the very similar level of abrasion for both specimens, as shown previously in table 2. For applications of bonding with paste adhesives, analysis with diffuse reflectance showed that surfaces properly prepared (no peel ply texture) versus surfaces improperly prepared (peel ply texture still evident) can be distinguished with PCA. This shows potential as a quality assurance method.

0= polyester peel ply surface

1= >75% peel ply surface evident 2= <50% peel ply surface evident

3=no peel ply surface evident

Page 14: infrared spectroscopy: a potential quality assurance method for

3.4 DATR Sampling Interface vs. Diffuse Reflectance Interface From the results presented in this paper, it was observed that the diffuse reflectance sampling interface showed greater sensitivity than the DATR sampling interface to both peel ply surface preparation and manual abrasion to remove peel ply surface. This could be due to the sampling volume difference between diffuse reflectance and DATR. DATR spectra come from the surface of the material that is in contact with the DATR crystal. Thus, DATR is well suited for smooth or compliant surfaces where a large fraction of the surface will contact the crystal. Rough, stiff surfaces are not as well suited, as there is less sample contact with the crystal. Figure 16 shows the area of a polyester peel ply surface that has been plastically deformed during application to the DATR crystal. As this figure shows, the entire surface is not in contact with the crystal, thus much of the surface does not contribute to the signal measured using DATR (i.e. no/little signal from the peel ply channels). Diffuse reflectance may be better suited for rough surfaces as contact with the surface is not required. Thus, individual peel ply channels contribute to the signal measured using diffuse reflectance. This difference in sampling volume between the two interfaces could explain the differences in sensitivity to the surface examined during this research.

Figure 16: Electron micrograph of polyester prepared CFRP surface after removal from DATR crystal. Ovals are drawn to highlight where surface shows contact with the DATR crystal.

4. CONCLUSIONS FTIR could be a potential quality assurance method for surface preparation for composites bonding. However, further research is necessary to understand the effects of surface preparation on IR spectra before application of FTIR as a quality assurance technique.

4.1 Peel Ply Type It was observed that DATR (bench-top instrument) showed no significant difference between peel ply surface preparation materials (nylon, polyester, SRB). Diffuse reflectance (handheld instrument), however, showed a difference between peel ply types. Using PLS, a method was developed for the Exoscan FTIR that correctly identified peel ply preparation type as polyester, nylon or SRB. Due to this success, diffuse reflectance FTIR has a potential application as a QA technique in the adhesive bonding process to identify peel ply preparation.

Page 15: infrared spectroscopy: a potential quality assurance method for

4.2 Peel Ply Contamination Previous residue test results show that DATR can detect siloxane contamination below which that it affects bond quality [6]. Initial analysis of siloxane contaminated samples with diffuse reflectance shows differences between samples but further research is necessary to understand these differences, as they do not appear to correlate to the amount of siloxane contamination transferred to the CFRP surfaces. However, PCA analysis of spectra collected with the Exoscan was able to differentiate between control samples (0%) and contaminated samples (0.1-2% and SRB). Hence, Exoscan FTIR could have application as a QA method for siloxane contamination but further research is needed to determine if a detection limit exists.

4.3 Manual Abrasion to Remove Peel Ply Texture PCA analysis of abraded samples examined with diffuse reflectance showed a difference between proper (peel ply surface removed) and improper (peel ply surface evident) abrasion levels. Use of the DATR sampling interface yielded less sensitivity. Therefore, diffuse reflectance shows potential as a QA tool for inspection of abraded surfaces to ensure the proper level of abrasion is reached before bonding applications such as those for use with paste adhesives.

5. ACKNOWLEDGMENTS The authors would like to thank the Boeing Company, particularly Pete VanVoast, Kay Blohowiak, William Grace, Paul Shelley, Paul Vahey and Greg Werner for their expertise and counsel.

6. REFERENCES 1. Kinloch, A.J. Adhesion and Adhesives Science and Technology. 1st. New York: Chapman

and Hall. 1987.

2. Hart-Smith, L.J., D. Brown, and S. Wong. Paper MDC 93K0126. 10th DoD/NASA/FAA Conference on Fibrous Composites in Structural Design – November 1993.

3. Flinn, B.D., and C.W. Hickmott. “Effect of Surface Preparation Technique on Bond Quality of AGATE Composite Laminates.” SAMPE 2009. Baltimore, MD, May 18-21, 2009

4. Flinn, B.D., B.K. Clark, J. Satterwhite and P. J. Van Voast. “Influence of Peel Ply Type on Adhesive Bonding of Composites.” SAMPE 2007. Baltimore, MD, June 3-7, 2007.

5. Phariss, M., and B. Flinn. “The Effect of Peel-Ply Surface Preparation Variables on Bond Quality.” DOT/FAA/(AR)-06/28. August 2006.

6. VanVoast, P.J., P.H. Shelley, R.L. Blakely, C.B. Smith, M.P. Jones, A.C. Tracey, B.D. Flinn, G. Dillingham, B. Oakley. “Effect of Varying Levels of Peel Ply Contamination on Adhesion Threshold.” SAMPE 2010. Seattle, WA, May 17-20, 2010.

7. Boerio, F.J., B. Roby, R.G. Dillingham, R.H. Bossi, R.L. Crane. “Effect of Grit Blasting on Surface Energy and Composition on Graphite/Epoxy Composites.” 37 ISTC. Seattle, WA, October 31-November 3, 2005.

Page 16: infrared spectroscopy: a potential quality assurance method for

8. Banea, M.D and L.F.M. da Silva. “Adhesively bonded joints in composite materials: an overview.” Journal of Materials: Design and Applications. 223.I (2009): 1-18.

9. Bossi, R., R. Carlsen, F.J. Boerio and G. Dillingham. “Composite Surface Preparation QA for Bonding.” SAMPE 2005. Long Beach, CA, May 1-5, 2005.

10. 4100 ExoScan Series FTIR (handheld). Photograph. 2000-2012. Agilent. Web. 20 Jan 2012. <www.chem.agilent.com>.

11. FT-IR-Spektrometer (BRUKER VERTEX 70). Photograph. Karlsruhe Institute of Technology: Institute for Inorganic Chemistry. Web. 20 Jan 2012. <www.aoc.kit.edu/english/612.php>

12. Enlow, E.M., J.L. Kennedy, A.A. Nieuwland, J.E. Hendrix and S.L. Morgan. “Discrimination of Nylon Polymers Using Attenuated Total Reflection Mid-Infrared Spectra and Multivariate Statistical Techniques.” Applied Spectroscopy. 59.8 (2005)

13. de la Caba, K., P. Guerrero, I. Mondragon and J.M. Kenny. “Comparative Study by DSC and FTIR Techniques of an Unsaturated Polyester Resin Cured at Different Temperatures.” Polymer International. 45.4 (1998): 333-38.

14. Hobbs, J.P., C.S.P. Sung, K. Krishnan and S. Hill. “Characterization of Surface Structure and Orientation in Polypropylene and Poly (ethylene terephthalate) Films by Modified Attenuated Total Reflection IR Dichroism Studies.” Macromolecules. 16.2 (1983): 193-99.