injection machine mds-iv_specs
TRANSCRIPT
ALL ELECTRIC INJECTIONMOLDING MACHINE
MDS-IVSPECIFICATIONS
MD 35 S-IVMD 55 S-IVMD 85 S-IVMD 110 S-IVMD 200 S-IVMD 310 S-IVMD 385 S-IVMD 500 S-IVMD 720 S-IVMD 950 S-IVMD 1100 S-IVMD 1550 S-IVMD 2000 S-IV
External Dimension DiagramMold Mounting Dimensional Diagram
Oth
ers
Inje
ctio
n U
nit
Cla
mpi
ng U
nit
Specifications
MD 35 S-IV
Unit
_
kN (USt)
(inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
kN (USt)
T•m
_
mm (inch)
mm (inch)
cm3 (cu.in)
g (oz)
MPa (PSI)
MPa (PSI)
mm/s (inch/s)
cm3/s (cu.in/s)
min-1
kg/h (oz/s)
mm (inch)
TONS
_
kW
kVA
t (USt)
m (inch)
m (inch)
m (inch)
L (gal.)
MD 35 S-IV
Double Toggle
300 (34)
4
280 x 280 (11.02 x 11.02)
410 x 410 (16.14 x 16.14)
230 (9.06)
150 / 300 (5.91 / 11.81)
530 (20.87)
50 (1.97)
15 (1.7)
i 0.7
Y A B
*18 (0.71) 22 (0.87) 25 (0.98)
85 (3.35)
22 (1.34) 32 (1.95) 42 (2.56)
20 (0.71) 30 (1.06) 38 (1.34)
280 (40610) 200 (29010) 155 (22480)
270 (39160) 180 (26110) 140 (20310)
300 (11.81)
76 (4.64) 114 (6.96) 147 (8.97)
400
10 (0.10) 20 (0.20) 30 (0.29)
225 (8.86)
1.69
1G + 3
2.99 3.50 4.19
15
2 (2.2)
2.85 (112.0)
0.99 (38.98)
1.56 (61.30)
15 (3.96)
Item
Clamping System
Clamping Force
Location Hole Diameter
Tie-Bar Distance
Platen Size
Max. Mold Open Stroke
Mold Height: Min. / Max.
Daylight
Ejector Stroke
Ejector Force
Injection Unit
Screw Type
Screw Diameter
Screw Stroke
Theoretical Shot Volume
Shot Mass
Max. Injection Pressure
Max. Holding Pressure
Max. Injection Speed
Injection Rate
Screw Speed
Plasticizing Capacity
Nozzle Stroke
Nozzle Touch Force
Automatic Temperature Control Zone
Heater Capacity
Machine kVA
Machine Mass
Machine L
Size W
H
Hopper Capacity
Notes: * “Y” size screws are optional.
NIIGATA distributed by DJK Global Groupwww.niigata-injection.com
1
External Dimension Diagram
Mold Mounting Dimensional Diagram 2
MD 35 S-IV
NIIGATA distributed by DJK Global Groupwww.niigata-injection.com
Oth
ers
Inje
ctio
n U
nit
Cla
mpi
ng U
nit
Specifications
MD 55 S-IV
Unit
_
kN (USt)
(inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
kN (USt)
T•m
_
mm (inch)
mm (inch)
cm3 (cu.in)
g (oz)
MPa (PSI)
MPa (PSI)
mm/s (inch/s)
cm3/s (cu.in/s)
min-1
kg/h (oz/s)
mm (inch)
TONS
_
kW
kVA
t (USt)
m (inch)
m (inch)
m (inch)
L (gal.)
Item
Clamping System
Clamping Force
Location Hole Diameter
Tie-Bar Distance
Platen Size
Max. Mold Open Stroke
Mold Height: Min. / Max.
Daylight
Ejector Stroke
Ejector Force
Injection Unit
Screw Type
Screw Diameter
Screw Stroke
Theoretical Shot Volume
Shot Mass
Max. Injection Pressure
Max. Holding Pressure
Max. Injection Speed
Injection Rate
Screw Speed
Plasticizing Capacity
Nozzle Stroke
Nozzle Touch Force
Automatic Temperature Control Zone
Heater Capacity
Machine kVA
Machine Mass
Machine L
Size W
H
Hopper Capacity
Notes: * “Y” size screws are optional.
MD 55 S-IV
Double Toggle
500 (56)
4
320 x 320 (12.60 x 12.60)
470 x 470 (18.50 x 18.50)
250 (9.84)
160 / 330 (6.30 / 13.00)
580 (22.84)
70 (2.76)
20 (2.2)
i 0.7 i 1.0
Y YA A B
*18 (0.71) 22 (0.87) 25 (0.98) 30 (1.18)
85 (3.35) 100 (3.94)
22 (1.34) 38 (2.32) 49 (2.99) 71 (4.33)
20 (0.71) 35 (1.23) 45 (1.59) 65 (2.29)
280 (40610) 250 (36260) 200 (29010) 140 (20310)
280 (40610) 230 (33360) 180 (26110) 125 (18130)
300 (11.81)
76 (4.64) 114 (6.96) 147 (8.97) 212 (12.94)
400
10 (0.10) 20 (0.20) 30 (0.29) 48 (0.47)
290 (11.42)
2.02
1G + 3
2.99 3.50 4.19
18
2.4 (2.6)
3.06 (120.4)
1.05 (41.34)
1.60 (62.80)
15 (3.96)
3
External Dimension Diagram
Mold Mounting Dimensional Diagram 4
MD 55 S-IV
Oth
ers
Inje
ctio
n U
nit
Cla
mpi
ng U
nit
Specifications
MD 85 S-IV
Unit
_
kN (USt)
(inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
kN (USt)
T•m
_
mm (inch)
mm (inch)
cm3 (cu.in)
g (oz)
MPa (PSI)
MPa (PSI)
mm/s (inch/s)
cm3/s (cu.in/s)
min-1
kg/h (oz/s)
mm (inch)
TONS
_
kW
kVA
t (USt)
m (inch)
m (inch)
m (inch)
L (gal.)
MD 85 S-IV
Double Toggle
750 (84)
4
360 x 360 (14.17 x 14.17)
530 x 530 (20.87 x 20.87)
300 (11.81)
170 / 380 (6.69 / 15.00)
680 (26.77)
80 (3.15)
25 (2.8)
i 1.7
Y YA A B
*25 (0.98) 28 (1.10) 30 (1.18) 35 (1.38)
120 (4.72)
59 (3.60) 74 (4.52) 85 (5.19) 115 (7.02)
54 (1.90) 68 (2.40) 78 (2.75) 106 (3.74)
280 (40610) 230 (33360) 200 (29010) 150 (21760)
260 (37710) 210 (30460) 180 (26110) 135 (19580)
300 (11.81)
147 (8.97) 185 (11.29) 212 (12.94) 289 (17.64)
400
30 (0.29) 40 (0.39) 48 (0.47) 67 (0.66)
340 (13.39)
2.42
1G + 3
5.10 6.35
26
3.5 (3.9)
3.59 (141.4)
1.09 (42.99)
1.71 (67.40)
15 (3.96)
Item
Clamping System
Clamping Force
Location Hole Diameter
Tie-Bar Distance
Platen Size
Max. Mold Open Stroke
Mold Height: Min. / Max.
Daylight
Ejector Stroke
Ejector Force
Injection Unit
Screw Type
Screw Diameter
Screw Stroke
Theoretical Shot Volume
Shot Mass
Max. Injection Pressure
Max. Holding Pressure
Max. Injection Speed
Injection Rate
Screw Speed
Plasticizing Capacity
Nozzle Stroke
Nozzle Touch Force
Automatic Temperature Control Zone
Heater Capacity
Machine kVA
Machine Mass
Machine L
Size W
H
Hopper Capacity
Notes: * “Y” size screws are optional.
NIIGATA distributed by DJK Global Groupwww.niigata-injection.com
5
External Dimension Diagram
Mold Mounting Dimensional Diagram 6
MD 85 S-IV
Oth
ers
Inje
ctio
n U
nit
Cla
mpi
ng U
nit
Specifications
MD 110 S-IV
Unit
_
kN (USt)
(inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
kN (USt)
T•m
_
mm (inch)
mm (inch)
cm3 (cu.in)
g (oz)
MPa (PSI)
MPa (PSI)
mm/s (inch/s)
cm3/s (cu.in/s)
min-1
kg/h (oz/s)
mm (inch)
TONS
_
kW
kVA
t (USt)
m (inch)
m (inch)
m (inch)
L (gal.)
MD 110 S-IV
Double Toggle
1000 (112)
4
410 x 410 (16.14 x 16.14)
610 x 610 (24.02 x 24.02)
350 (13.78)
200 / 410 (7.87 / 16.14)
760 (29.92)
100 (3.94)
30 (3.4)
i 2.7
Y YA A B
*30 (1.18) 32 (1.26) 35 (1.38) 40 (1.57)
140 (5.51)
99 (6.04) 113 (6.90) 135 (8.24) 176 (10.74)
91 (3.21) 104 (3.67) 124 (4.37) 162 (5.71)
270 (39160) 240 (34810) 200 (29010) 155 (22480)
245 (35530) 215 (31180) 180 (26110) 135 (19580)
300 (11.81)
212 (12.94) 241 (14.71) 289 (17.64) 377 (23.01)
400
48 (0.47) 57 (0.56) 67 (0.66) 98 (0.96)
370 (14.57)
3.26
1G + 3
6.95 8.15
34
4.7 (5.2)
4.00 (157.4)
1.11 (43.66)
1.78 70.04)
45 (11.89)
Item
Clamping System
Clamping Force
Location Hole Diameter
Tie-Bar Distance
Platen Size
Max. Mold Open Stroke
Mold Height: Min. / Max.
Daylight
Ejector Stroke
Ejector Force
Injection Unit
Screw Type
Screw Diameter
Screw Stroke
Theoretical Shot Volume
Shot Mass
Max. Injection Pressure
Max. Holding Pressure
Max. Injection Speed
Injection Rate
Screw Speed
Plasticizing Capacity
Nozzle Stroke
Nozzle Touch Force
Automatic Temperature Control Zone
Heater Capacity
Machine kVA
Machine Mass
Machine L
Size W
H
Hopper Capacity
Notes: * “Y” size screws are optional.
NIIGATA distributed by DJK Global Groupwww.niigata-injection.com
7
MD 110 S-IVExternal Dimension Diagram
Mold Mounting Dimensional Diagram 8
i 6.5
Y A B
*40 (1.57) 45 (177) 52 (2.05)
205 (8.07)
258 (15.74) 326 (19.89) 435 (26.55)
237 (8.36) 300 (10.58) 401 (14.14)
250 (36260) 200 (29010) 150 (21760)
225 (32630) 180 (26110) 135 (19580)
300 (11.81)
377 (23.00) 477 (29.11) 637 (38.87)
400
113 (1.11) 148 (1.45) 228 (2.23)
410 (16.14)
4.5
1G + 3
11.19 14.19
61
8.5 (9.4)
5.1 (200.6)
1.5 (59.00)
2.1 (80.71)
45 (11.89)
i 4.0
Y A B
*35 (1.38) 40 (1.57) 45 (1.77)
160 (6.30)
154 (9.40) 201 (12.27) 254 (15.50)
142 (5.01) 185 (6.53) 234 (8.25)
260 (37710) 200 (29010) 155 (22480)
235 (34080) 180 (26110) 140 (20310)
300 (11.81)
286 (17.45) 373 (22.76) 472 (28.80)
400
63 (0.62) 103 (1.01) 128 (1.25)
410 (16.14)
4.5
1G + 3
9.35 10.55
46
7.3 (8.0)
4.6 (180.7)
1.5 (59.00)
1.9 (72.87)
45 (11.89)
Oth
ers
Inje
ctio
n U
nit
Cla
mpi
ng U
nit
Specifications
MD 200 S-IV
Unit
_
kN (USt)
(inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
kN (USt)
T•m
_
mm (inch)
mm (inch)
cm3 (cu.in)
g (oz)
MPa (PSI)
MPa (PSI)
mm/s (inch/s)
cm3/s (cu.in/s)
min-1
kg/h (oz/s)
mm (inch)
TONS
_
kW
kVA
t (USt)
m (inch)
m (inch)
m (inch)
L (gal.)
MD 200 S-IV
Double Toggle
1800 (202)
4
530 x 530 (20.87 x 20.87)
770 x 770 (30.31 x 30.31)
450 (17.72)
200 / 500 (7.87 / 19.69)
950 (37.40)
110 (4.33)
45 (5.06)
Item
Clamping System
Clamping Force
Location Hole Diameter
Tie-Bar Distance
Platen Size
Max. Mold Open Stroke
Mold Height: Min. / Max.
Daylight
Ejector Stroke
Ejector Force
Injection Unit
Screw Type
Screw Diameter
Screw Stroke
Theoretical Shot Volume
Shot Mass
Max. Injection Pressure
Max. Holding Pressure
Max. Injection Speed
Injection Rate
Screw Speed
Plasticizing Capacity
Nozzle Stroke
Nozzle Touch Force
Automatic Temperature Control Zone
Heater Capacity
Machine kVA
Machine Mass
Machine L
Size W
H
Hopper Capacity
Notes: * “Y” size screws are optional.
NIIGATA distributed by DJK Global Groupwww.niigata-injection.com
9
MD 200 S-IVExternal Dimension Diagram
Mold Mounting Dimensional Diagram 10
Oth
ers
Inje
ctio
n U
nit
Cla
mpi
ng U
nit
Specifications
MD 310 S-IV
Unit
_
kN (USt)
(inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
kN (USt)
T•m
_
mm (inch)
mm (inch)
cm3 (cu.in)
g (oz)
MPa (PSI)
MPa (PSI)
mm/s (inch/s)
cm3/s (cu.in/s)
min-1
kg/h (oz/s)
mm (inch)
TONS
_
kW
kVA
t (USt)
m (inch)
m (inch)
m (inch)
L (gal.)
MD 310 S-IV
Double Toggle
2800 (315)
4
630 x 630 (24.80 x 24.80)
930 x 930 (36.61 x 36.61)
600 (23.62)
250 / 620 (9.84 / 24.41)
1220 (48.03)
130 (5.12)
60 (6.74 )
i 11
A B
52 (2.05) 60 (2.36)
260 (10.24)
552 (33.69) 735 (44.85)
508 (17.92) 676 (23.81)
200 (29010) 150 (21760)
180 (26110) 135 (19580)
300 (11.81)
637 (38.87) 848 (51.75)
300
151 (1.48) 206 (2.02)
435 (17.13)
5.28
1G + 3
18.69
87
13.3 (14.6)
5.9 (231.6)
1.8 (69.29)
2.2 (86.73)
80 (21.13)
Item
Clamping System
Clamping Force
Location Hole Diameter
Tie-Bar Distance
Platen Size
Max. Mold Open Stroke
Mold Height: Min. / Max.
Daylight
Ejector Stroke
Ejector Force
Injection Unit
Screw Type
Screw Diameter
Screw Stroke
Theoretical Shot Volume
Shot Mass
Max. Injection Pressure
Max. Holding Pressure
Max. Injection Speed
Injection Rate
Screw Speed
Plasticizing Capacity
Nozzle Stroke
Nozzle Touch Force
Automatic Temperature Control Zone
Heater Capacity
Machine kVA
Machine Mass
Machine L
Size W
H
Hopper Capacity
Notes: * “Y” size screws are optional.
NIIGATA distributed by DJK Global Groupwww.niigata-injection.com
11
MD 310 S-IVExternal Dimension Diagram
Mold Mounting Dimensional Diagram 12
Cla
mpi
ng U
nit
i 22
A B
68 (2.68) 76 (2.99)
305 (12.01)
1107 (67.55) 1383 (84.40)
1018 (35.91) 1272 (44.87)
200 (29010) 160 (23210)
180 (26110) 145 (21030)
200 (7.9)
726 (44.30) 907 (55.35)
240
252 (2.47) 295 (2.89)
435 (17.13)
5.61
1G + 3
25.06
93
17.5 (19.3)
6.8 (269.6)
1.8 (70.67)
2.1 (84.25)
80 (21.13)
i 11
A B
52 (2.05) 60 (2.36)
260 (10.24)
552 (33.69) 735 (44.85)
508 (17.92) 676 (23.81)
200 (29010) 150 (21760)
180 (26110) 135 (19580)
300 (11.81)
637 (38.87) 848 (51.75)
300
151 (1.48) 206 (2.02)
435 (17.13)
5.28
1G + 3
18.69
87
16.3 (17.9)
6.3 (248.2)
1.7 (66.8)
2.2 (86.73)
80 (21.13)
NIIGATA distributed by DJK Global Groupwww.niigata-injection.com
Oth
ers
Inje
ctio
n U
nit
Specifications
MD 385 S-IV
Unit
_
kN (USt)
(inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
kN (USt)
T•m
_
mm (inch)
mm (inch)
cm3 (cu.in)
g (oz)
MPa (PSI)
MPa (PSI)
mm/s (inch/s)
cm3/s (cu.in/s)
min-1
kg/h (oz/s)
mm (inch)
TONS
_
kW
kVA
t (USt)
m (inch)
m (inch)
m (inch)
L (gal.)
Item
Clamping System
Clamping Force
Location Hole Diameter
Tie-Bar Distance
Platen Size
Max. Mold Open Stroke
Mold Height: Min. / Max.
Daylight
Ejector Stroke
Ejector Force
Injection Unit
Screw Type
Screw Diameter
Screw Stroke
Theoretical Shot Volume
Shot Mass
Max. Injection Pressure
Max. Holding Pressure
Max. Injection Speed
Injection Rate
Screw Speed
Plasticizing Capacity
Nozzle Stroke
Nozzle Touch Force
Automatic Temperature Control Zone
Heater Capacity
Machine kVA
Machine Mass
Machine L
Size W
H
Hopper Capacity
Notes: * “Y” size screws are optional.
MD 385 S-IV
Double Toggle
3500 (394)
4
730 x 730 (28.74 x 28.74)
1040 x 1040 (40.94 x 40.94)
650 (25.60)
320 / 670 (12.60 / 26.38)
1320 (51.97)
150 (5.91)
78 (8.77)
13
External Dimension Diagram
Mold Mounting Dimensional Diagram 14
MD 385 S-IV
Oth
ers
Inje
ctio
n U
nit
Cla
mpi
ng U
nit
Specifications
MD 500 S-IV
Unit
_
kN (USt)
(inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
kN (USt)
T•m
_
mm (inch)
mm (inch)
cm3 (cu.in)
g (oz)
MPa (PSI)
MPa (PSI)
mm/s (inch/s)
cm3/s (cu.in/s)
min-1
kg/h (oz/s)
mm (inch)
TONS
_
kW
kVA
t (USt)
m (inch)
m (inch)
m (inch)
L (gal.)
MD 500 S-IV
Double Toggle
4500 (506)
4
810 x 810 (31.89 x 31.89)
1160 x 1160 (45.67 x 45.67)
800 (31.50)
380 / 750 (14.96 / 29.53)
1550 (61.02)
160 (6.30)
100 (11.24)
i 32
A B
76 (2.99) 82 (3.23)
350 (13.78)
1588 (96.91) 1848 (112.77)
1460 (51.50) 1699 (59.93)
200 (29010) 170 (24660)
180 (26110) 155 (22480)
160 (6.30)
726 (44.30) 845 (51.56)
200
256 (2.51) 299 (2.93)
560 (22.05)
2.2
1G + 4
33.16
159
25.6 (28.2)
8.2 (321.3)
2.0 (76.57)
2.3 (89.06)
120 (31.70)
Item
Clamping System
Clamping Force
Location Hole Diameter
Tie-Bar Distance
Platen Size
Max. Mold Open Stroke
Mold Height: Min. / Max.
Daylight
Ejector Stroke
Ejector Force
Injection Unit
Screw Type
Screw Diameter
Screw Stroke
Theoretical Shot Volume
Shot Mass
Max. Injection Pressure
Max. Holding Pressure
Max. Injection Speed
Injection Rate
Screw Speed
Plasticizing Capacity
Nozzle Stroke
Nozzle Touch Force
Automatic Temperature Control Zone
Heater Capacity
Machine kVA
Machine Mass
Machine L
Size W
H
Hopper Capacity
Notes: * “Y” size screws are optional.
NIIGATA distributed by DJK Global Groupwww.niigata-injection.com
15
External Dimension Diagram
16
MD 500 S-IV
Mold Mounting Dimensional Diagram
Oth
ers
Inje
ctio
n U
nit
Cla
mpi
ng U
nit
Specifications
MD 720 S-IV
Unit
_
kN (USt)
(inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
kN (USt)
T•m
_
mm (inch)
mm (inch)
cm3 (cu.in)
g (oz)
MPa (PSI)
MPa (PSI)
mm/s (inch/s)
cm3/s (cu.in/s)
min-1
kg/h (oz/s)
mm (inch)
TONS
_
kW
kVA
t (USt)
m (inch)
m (inch)
m (inch)
L (gal.)
MD 720 S-IV
Double Toggle
6370 (716)
4
950 x 950 (37.40 x 37.40)
1390 x 1390 (54.72 x 54.72)
1000 (39.37)
400 / 1040 (15.75 x 40.94)
2040 (80.31)
180 (7.09)
196 (22.03)
i 55
A B
90 (3.53) 100 (3.94)
450 (17.72)
2863 (174.7) 3534 (215.66)
2634 (92.91) 3252 (114.71)
190 (27560) 155 (22480)
170 (24660) 140 (20310)
150 (5.91)
954 (58.22) 1178 (71.89)
130
309 (3.03) 327 (3.20)
600 (23.62)
4.4
1G + 5
35.65
190
38 (41.8)
10.5 (413.3)
2.2 (87.83)
2.4 (92.52)
120 (31.70)
Item
Clamping System
Clamping Force
Location Hole Diameter
Tie-Bar Distance
Platen Size
Max. Mold Open Stroke
Mold Height: Min. / Max.
Daylight
Ejector Stroke
Ejector Force
Injection Unit
Screw Type
Screw Diameter
Screw Stroke
Theoretical Shot Volume
Shot Mass
Max. Injection Pressure
Max. Holding Pressure
Max. Injection Speed
Injection Rate
Screw Speed
Plasticizing Capacity
Nozzle Stroke
Nozzle Touch Force
Automatic Temperature Control Zone
Heater Capacity
Machine kVA
Machine Mass
Machine L
Size W
H
Hopper Capacity
Notes: * “Y” size screws are optional.
NIIGATA distributed by DJK Global Groupwww.niigata-injection.com
17
External Dimension Diagram
MD 720 S-IV
Mold Mounting Dimensional Diagram 18
Oth
ers
Inje
ctio
n U
nit
Cla
mpi
ng U
nit
Specifications
MD 950 S-IV
Unit
_
kN (USt)
(inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
kN (USt)
T•m
_
mm (inch)
mm (inch)
cm3 (cu.in)
g (oz)
MPa (PSI)
MPa (PSI)
mm/s (inch/s)
cm3/s (cu.in/s)
min-1
kg/h (oz/s)
mm (inch)
TONS
_
kW
kVA
t (USt)
m (inch)
m (inch)
m (inch)
L (gal.)
MD 950 S-IV
Double Toggle
8330 (936)
5
1060 x 1060 (41.73 x 41.73)
1560 x 1560 (61.42 x 61.42)
1200 (47.24)
500 / 1240 (19.69 / 48.82)
2440 (96.06)
200 (7.87)
245 (27.54)
i 74
A B
100 (3.94) 112 (4.41)
500 (19.69)
3927 (239.64) 4926 (300.60)
3613 (127.44) 4532 (159.86)
185 (26830) 150 (21760)
170 (24660) 135 (19580)
150 (5.91)
1178 (71.89) 1478 (90.19)
120
430 (4.21) 450 (4.41)
700 (27.56)
4.4
1G + 5
51.25
240
49 (53.9)
11.5 (454.0)
2.4 (96.5)
2.5 (98.0)
120 (31.70)
Item
Clamping System
Clamping Force
Location Hole Diameter
Tie-Bar Distance
Platen Size
Max. Mold Open Stroke
Mold Height: Min. / Max.
Daylight
Ejector Stroke
Ejector Force
Injection Unit
Screw Type
Screw Diameter
Screw Stroke
Theoretical Shot Volume
Shot Mass
Max. Injection Pressure
Max. Holding Pressure
Max. Injection Speed
Injection Rate
Screw Speed
Plasticizing Capacity
Nozzle Stroke
Nozzle Touch Force
Automatic Temperature Control Zone
Heater Capacity
Machine kVA
Machine Mass
Machine L
Size W
H
Hopper Capacity
Notes: * “Y” size screws are optional.
NIIGATA distributed by DJK Global Groupwww.niigata-injection.com
19
External Dimension Diagram
MD 950 S-IV
Mold Mounting Dimensional Diagram 20
Oth
ers
Inje
ctio
n U
nit
Cla
mpi
ng U
nit
Specifications
MD 1100 S-IV
Unit
_
kN (USt)
(inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
kN (USt)
T•m
_
mm (inch)
mm (inch)
cm3 (cu.in)
g (oz)
MPa (PSI)
MPa (PSI)
mm/s (inch/s)
cm3/s (cu.in/s)
min-1
kg/h (oz/s)
mm (inch)
TONS
_
kW
kVA
t (USt)
m (inch)
m (inch)
m (inch)
L (gal.)
MD 1100 S-IV
Double Toggle
9800 (1102)
5
1270 x 1270 (50.0 x 50.0)
1820 x 1820 (71.65 x 71.65)
1400 (55.12)
500 / 1240 (19.69 / 48.82)
2640 (103.94)
200 (7.87)
245 (27.54)
i 74
A B
100 (3.94) 112 (4.41)
500 (19.69)
3927 (239.64) 4926 (300.60)
3613 (127.44) 4532 (159.86)
185 (26830) 150 (21760)
170 (24660) 135 (19580)
150 (5.91)
1178 (71.89) 1478 (90.19)
120
430 (4.21) 450 (4.41)
730 (28.74)
4.4
1G + 5
51.25
240
61 (67.1)
12.3 (482.4)
2.7 (107.2)
2.5 (98.0)
120 (31.70)
Item
Clamping System
Clamping Force
Location Hole Diameter
Tie-Bar Distance
Platen Size
Max. Mold Open Stroke
Mold Height: Min. / Max.
Daylight
Ejector Stroke
Ejector Force
Injection Unit
Screw Type
Screw Diameter
Screw Stroke
Theoretical Shot Volume
Shot Mass
Max. Injection Pressure
Max. Holding Pressure
Max. Injection Speed
Injection Rate
Screw Speed
Plasticizing Capacity
Nozzle Stroke
Nozzle Touch Force
Automatic Temperature Control Zone
Heater Capacity
Machine kVA
Machine Mass
Machine L
Size W
H
Hopper Capacity
Notes: * “Y” size screws are optional.
NIIGATA distributed by DJK Global Groupwww.niigata-injection.com
21
External Dimension Diagram
MD 1100 S-IV
Mold Mounting Dimensional Diagram 22
Oth
ers
Inje
ctio
n U
nit
Cla
mpi
ng U
nit
Specifications
MD 1550 S-IV
MD 1550 S-IV
Double Toggle
13700 (1550)
5
1830 x 1510 (72 x 59.5)
2480 x 1970 (97.6 x 77.55)
1500 (59)
650 / 1300 (25.59 / 51.18)
2800 (110.23)
250 (9.84)
323 (36.2)
i 154
A B
120 (4.72) 132 (5.2)
720 (28.34)
8143 (496.91) 9853 (601.26)
7491 (264.23) 9065 (319.75)
185 (26830) 150 (21760)
170 (24660) 135 (19580)
125 (4.92)
1413 (94.62) 1710 (104.34)
110
600 (4.21) 580 (4.41)
880 (34.65)
6.6
7
56 60
272
104 (144.4)
15 (592)
3.8 (150.7)
3.1 (122.1)
Item
Clamping System
Clamping Force
Location Hole Diameter
Tie-Bar Distance
Platen Size
Max. Mold Open Stroke
Mold Height: Min. / Max.
Daylight
Ejector Stroke
Ejector Force
Injection Unit
Screw Type
Screw Diameter
Screw Stroke
Theoretical Shot Volume
Shot Mass
Max. Injection Pressure
Max. Holding Pressure
Max. Injection Speed
Injection Rate
Screw Speed
Plasticizing Capacity
Nozzle Stroke
Nozzle Touch Force
Automatic Temperature Control Zone
Heater Capacity
Machine kVA
Machine Mass
Machine L
Size W
H
Notes: * “Y” size screws are optional.
NIIGATA distributed by DJK Global Groupwww.niigata-injection.com
Unit
_
kN (USt)
(inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
kN (USt)
T•m
_
mm (inch)
mm (inch)
cm3 (cu.in)
g (oz)
MPa (PSI)
MPa (PSI)
mm/s (inch/s)
cm3/s (cu.in/s)
min-1
kg/h (oz/s)
mm (inch)
TONS
_
kW
kVA
t (USt)
m (inch)
m (inch)
m (inch)
23
Oth
ers
Inje
ctio
n U
nit
Cla
mpi
ng U
nit
Specifications
MD 2000 S-IV
MD 2000 S-IV
Double Toggle
17600 (2000)
5
2169 x 1661 (85.4 x 65.4)
3175 x 2413 (125 x 95)
1700 (67)
800 / 1900 (31.5 / 74.8)
3600 (141.75)
300 (11.8)
323 (36.2)
i 154
A B
120 (4.72) 132 (5.2)
720 (28.34)
8143 (496.91) 9853 (601.26)
7491 (264.23) 9065 (319.75)
185 (26830) 150 (21760)
170 (24660) 135 (19580)
125 (4.92)
1413 (94.62) 1710 (104.34)
110
600 (4.21) 580 (4.41)
880 (34.65)
6.6
7
56 60
272
197 (216.7)
16.8 (662.6)
4.6 (180.1)
3.5 (137.4)
Item
Clamping System
Clamping Force
Location Hole Diameter
Tie-Bar Distance
Platen Size
Max. Mold Open Stroke
Mold Height: Min. / Max.
Daylight
Ejector Stroke
Ejector Force
Injection Unit
Screw Type
Screw Diameter
Screw Stroke
Theoretical Shot Volume
Shot Mass
Max. Injection Pressure
Max. Holding Pressure
Max. Injection Speed
Injection Rate
Screw Speed
Plasticizing Capacity
Nozzle Stroke
Nozzle Touch Force
Automatic Temperature Control Zone
Heater Capacity
Machine kVA
Machine Mass
Machine L
Size W
H
Notes: * “Y” size screws are optional.
NIIGATA distributed by DJK Global Groupwww.niigata-injection.com
Unit
_
kN (USt)
(inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
kN (USt)
T•m
_
mm (inch)
mm (inch)
cm3 (cu.in)
g (oz)
MPa (PSI)
MPa (PSI)
mm/s (inch/s)
cm3/s (cu.in/s)
min-1
kg/h (oz/s)
mm (inch)
_
kW
kVA
t (USt)
m (inch)
m (inch)
m (inch)
L (gal.)
24
Con
trol
Ala
rms
Cla
mpi
ngIn
ject
ion
Multistage injection speed control: 10 speeds / Filling pressures for each speed stageMultistage injection pressure control: 10 pressures / Holding speeds for each pressure stageMultistage screw recovery control: 3 speeds, 3 back pressuresNozzle temperature group controlInjection unit swivel device (Powered swivel for 500 ton and larger models)Cold screw starting preventionBarrel heater coverAutomatic purgeHopper base temperature controlBack pressure delete in manual modePurge guard
Multistage mold open/close speed control: 6 speedsMovable platen support (4 points support for 500 ton and smaller models, 2 points for 720 ton and larger)Automatic mold height/clamping force adjustmentLow pressure mold protectionEjector advance position holding functionMold set mode with low speed/low pressureMechanical mold closing safety device (Pneumatic powered by electric signal for 720 ton and above)Robot mounting holdAir ejectCore pull interface12.1 inch color LCD touch panel
Ejector on the fly • Recovery on the fly (Standard for 500 ton and larger models)Delay timers for injection, screw recovery, nozzle and ejectorExpert function (Initial condition setting/Setting conversion from other machines)Barrel follow-up temperature control for nozzle zoneCalender timer for heater startupMultiple language (English, Japanese, Chinese, Spanish)Mold memory storage/reset (32 set-ups)Mold trial set-up memory (10 set-ups)Graphic monitor for injection speed and pressureHour meter for maintenanceServo motor monitor100-shot monitorRecords for parameter input, alarm and rejection productMonitoring data statistic processingPhysical value setting (Speed, resin pressure, screw speed)Select switch for machine shut down alarmAlarm buzzerS.P.I. Robot InterfacePrinter interfaceAutomatic lubrication abnormal alarm
Servomotor abnormal alarmMotor thermal abnormal alarm (Carriage motor, mold height adjustment motor)V-P transfer alarm (Time, position, pressure)Screw recovery time alarmCycle time alarmBarrel temperature alarmHopper base temperature alarmHeater break alarmSSR abnormal alarmThermocouple break alarmTemperature regulator preparation alarmResin lack alarmClamp alarmProduction shot counter (preset type)
1234567891011
1213141516171819202122
2324252627282930313233343536373839404142
4344454647484950515253545556
NIIGATA distributed by DJK Global Groupwww.niigata-injection.com
Standard Accessories
MD S-IV
25
Standard Accessories Continued
Oth
ers
Cou
nter
s
Preparation shot counter (preset type)Reject shot counter (preset type)Reject continuous shot counter (preset counter)Shot counter for external conveyorInjection monitor at flexible screw position
Auto LubricationSpare grease cartridgeEmergency stop button with lockLeveling pads for 500 ton and smaller models (Anchor bolts recommended for 720 ton and larger models)Special toolsLow pressure mold clamping holding device
575859606162
6364656667
Optional AccessoriesRecovery on the flyExternal floppy disk drive memoryI/C Memory card readerPrinterEjector compression system (ECS)Small size screw completeAnti-wearing screw and barrelHigh temperature molding specialityOptional nozzle (long open/needle)Ejector plate return confirmationSpecial locating ringHeat insulating board (thickness: 5mm)Interface for product drop detectorProducts chuteQuality discriminate detectorWarning lightOutletInterface for hot runnerInterface for unscrewing device (motor excluded)Mold temperature regulator (electric heater)Earth leakage breaker
123456789101112131415161718192021
MD S-IV
26
NIIGATA MACHINE TECHNO COMPANY, INC.
DJK Global Group245 Spring Lake DriveItasca IL 60143Phone: 630-875-0202fax: 630-875-0422TOLL FREE: 800-843-1672
www.niigata-injection.com