innovative and reliable protection
TRANSCRIPT
INNOVATIVE ANDRELIABLE PROTECTION.
Exam Gloves for Acute Care Outstanding Selection, Fit and Performance.
Page 3 Page 2
Thanks to advancements in technology, exam gloves today have more features and benefits than ever existed before. Selecting the right glove is a challenge. Medline wants to make it easier for you to evaluate all the options. This new guide to Medline exam gloves clarifies the differences between major glove types to help you make an informed decision. It even contains a “Gloves by Department” section that matches glove properties to the typical requirements of specific areas in the hospital.
Medline is focusing on the future by developing new gloves that use the very latest technology to provide outstanding fit, comfort and performance. For example, our RestoreTM gloves are lined with a premium coating of colloidal oatmeal that soothes healthcare workers’ hands, while our improved nitrile gloves offer great strength and are more comfortable than ever.
As always, we welcome your suggestions. Tripp AmdurGroup PresidentMedline International BV
THE MEDLIN
E DIFFERENCE
THE MEDLINE DIFFERENCEMedline exam gloves are designed and manufactured to meet the needs of healthcare workers. The details make the Medline difference. All Medline gloves feature flat layer packing and the premium gloves feature MicroStop™ film and colour-coded sizing ring.
Flat Layer PackagingPackaging quality is a critical component of exam glove manufacturing; failing to deliver excellence in this regard can create significant end user waste, frustration and inefficiency. Medline’s proprietary packing system delivers excellent flat layer packaging with every box allowing more gloves to be packed per box without drastically increasing box size. Flat layer packaging also enables the user to easily dispense one glove.
CONTENTS:
- The Medline Difference 3
- Premium Coated Gloves 4
- Nitrile Gloves 5
- Generation Pink 5
- Premium Vinyl Gloves 6
- Item Index 7
- Glove by Department 8-9
- Glove Properties and Chemical Resistance 10-11
MicroStop™ FilmRestore, Sensicare Free, Sensicare Ice and Sensicare Silk exam gloves are all protected with MicroStop™ film. MicroStop™ covers the box opening and reduces end user waste by controlling the number of gloves dispensed at one time.
Colour-Coded SizingMedline’s colour-coded sizing system allows for easy size identification and reduces waste and inefficiency associated with selecting the wrong size. All Medline glove boxes feature a large, coloured letter indicating the size. Select gloves such as Restore, Sensicare Free, Sensicare Ice and Sensicare Silk exam gloves also feature a colour-coded ring around the box opening.
Page 5 Page 4
NITRILE
NIT
RILE
THIC
K Aloetouch powder-free nitrileAn excellent choice for complete protection. Available in 300mm. Chemo-tested. Ref. MDS195184/87
Aloe Vera - innovation that soothes hands
Another solution to keep your hard working hands healthy is with Medline’s Aloe Vera exam gloves.
How it worksIn 1999, Medline changed the industry by patenting a process to bring the moisturising properties ofaloe vera to medical gloves. AloeTouch technology works by extracting 100% pure organic aloe veragel directly from the plant, freeze-drying it and evenly applying it to the inner surface of the glove.Within 30 seconds of use, the glove wearer’s body heat activates the aloe coating to create a therapeuticmoisturising experience.
The Aloetouch Extended Cuff exam glove provides additional protection for high-risk procedures withan extended cuff that protects the area between the cuff and sleeve. This glove is textured for a securegrip and tested for use with chemotherapy drugs.
Benefits of Better Skin ConditionPromotes compliance with hand washing and glove protocolsHigh satisfaction among clinicians
PREM
IUM
COA
TED
NIT
RILE
HO
USEW
IDE
VIN
YL3G
PROTECTION WITH A CAUSE. GENERATION PINK GLOVES One Mission. Two Gloves.
Medline started the Generation Pink movement with a single vision: A World Without Breast Cancer Is in Our Hands®. Medline is committed to improving the lives of patients and people, and our breast cancer awareness campaign is a natural extension of that commitment.
Medline now has two Generation Pink gloves that help support programs for breast cancer awareness, early detection and prevention among underserved women. Wearing the pink gloves helps show your support.
Trust our nitrile gloves for strength with a soft touch.
Medline has made a significant investment to improve the technology of nitrile gloves to increase the softness while maintaining excellent resistance and barrier protection. Our nitrile gloves are now more comfortable to wear and more affordable.
Proven Chemical ResistanceNitrile gloves are stronger and possess greater chemical resistance than both latex and vinyl gloves. They are generally recommended for use in areas that involve higher levels of stress on exam gloves (e.g., ED and Trauma units) or areas that deal with harsh chemicals or liquid immersion (e.g., Lab, Oncology, Environmental Services, Endoscopy, and Pharmacy).
SUPREME PROTECTION AND COMFORT WITH NITRILE GLOVES
GENERATION
PINK
*Chemo-Tested: Glove is tested for use with major chemotherapy agents.
Generation Pink powder-free nitrileExcellent tactile sensitivity. Textured fingertips. Ref. PINKE6800/04
Generation Pink powder-free 3G vinyl The most advanced vinyl available. Ref. PINK6073/77
NIT
RILE
HO
USEW
IDE
Restore powder-free nitrile Coated with colloidal oatmeal USP skin protectant that can temporarily protect and help relieve minor skin irritation. Chemo-tested. Ref. OAT-XS/OAT-XL
SOOTHE THE SKIN WITH PREMIUM COATED GLOVES Medline’s RestoreTM coated gloves are designed for hard-working hands.
Healthcare providers must constantly wash their hands and wear gloves as an infection control measure. Repeated glove use and exposure to harsh chemicals can lead to contact dermatitis. Glove powder can dry out skin and make these problems even worse. Lotions and creams can help, but many health care workers must visit occupational health and dermatologists, and may be forced to take time off to allow their skin condition to improve, costing hospitals money. Thankfully, there’s another way to keep your hard working hands healthy. Restore nitrile gloves are Medline’s first glove to use colloidal oatmeal to add comfort to the most valuable tools, the hands of your staff.
Colloidal oatmeal is simply oats that have been ground very fine to provide maximum benefit by exposing more of its valuable components. The FDA (United States Food and Drug Administration) has indicated that colloidal oatmeal can temporarily protect and help relieve minor skin irritation and itching due to rashes or eczema.
Benefits of Better Skin Condition Promotes compliance with hand washing and glove protocolsHigh satisfaction among clinicians
HO
USEW
IDE
SensiCare® Ice powder-free nitrile Provides great sensitivity and dependable protection. Chemo-tested*. Ref. 486800/04
MediGuard Blue powder-free nitrile High-performance protection not made with natural rubber latex. A soft, strong glove with good tactile sensitivity. Chemo-tested*. Ref. EM5050/54
THIC
K
SensiCare® extended cuff powder-free nitrile Extended cuff for extra protection. Excellent tactile sensitivity. Chemo-tested*. Ref. MDS1284/87 SensiCare® Pro 400 powder-free nitrile400 mm cuffs provide extra protection between the cuff and sleeve. Our thickest nitrile option with full texture for better grip. Chemo-Tested*. Ref. PRO400XS/XL
SEN
SITI
VE
SensiCare® Silk powder-free nitrile Our highest level of tactile sensitivity. Dark-blue colour. Chemo-tested*. Ref. MDS9083/87 SensiCare® Free powder-free nitrile Accelerator free glove for healthcare workers with accelerator allergies. Dark-blue colour. Chemo-tested*. Ref. MDSFREE-XS/XL
Page 7 Page 6
PREM
IUM
VIN
YL
Force at Break (Newtons) and Strength
3.6
5.1
4.5
Elongation/ stretch
300%
540%
375%
EN45
5-2
3rd
Gene
ratio
n(U
nive
rsal
3G)
1st G
ener
atio
n(C
lear
Vin
yl)
3rd
Gene
ratio
n(U
nive
rsal
3G)
ASTM
D
5250
-00
1st G
ener
atio
n(C
lear
Vin
yl)
BETTER PERFORMANCE WITH PREMIUM VINYL GLOVES Medline vinyl synthetic gloves: all-around performance made better by technology.
Advances in vinyl synthetic glove technology have enabled Medline to make significant improvements in the features that matter most to you: strength, elongation, tactile sensitivity and comfort.
An Ideal Alternative to LatexMedline's third generation vinyl synthetic gloves offer a cost-effective alternative for the majority of clinical applications. Except for a few instances that call for specialty gloves (e.g., chemotherapy gloves in Oncology), stretch vinyl gloves are an excellent choice for economical barrier protection.
Multiple Generations...What’s the Difference? These charts show how tensile strength and elongation improve with each successive generation.
*Data on File
VIN
YL3G
CURAD 3G third-generation powder-free stretch vinylOutstanding comfort and performance. Proprietary formulation offers remarkable softness, strength and stretchability. Ref. CUR8233/37
1G First generation powder free clear vinyl
Classic clear vinyl with 50% more per box.Ref. MGE323/27
ITEM INDEX
DESCRIPTION QTY PER CASE X-SMALL SMALL MEDIUM LARGE X-LARGE
PREM
IUM
CO
ATED
Aloetouch Ext Cuff PF Nitrile
500 ea — MDS195184 MDS195185 MDS195186 MDS195187
Restore PF with Microstop*
2,000 ea /1,800 ea XL
OAT-XS OAT-S OAT-M OAT-L OAT-XL
PIN
K
Generation Pink PF Nitrile
2,000 ea /1,800 ea XL
PINKE6800 PINKE6801 PINKE6802 PINKE6803 PINKE6804
Generation Pink PF 3G Vinyl
1,000 ea / 900 ea XL
PINK6073 PINK6074 PINK6075 PINK6076 PINK6077
Sensicare Pro PF Nitrile* powder free nitrile
500 ea PRO400XS PRO400S PRO400M PRO400L PRO400XL
NIT
RILE
SensiCare Extended Cuff* powder free nitrile
500 ea /450 ea XL
— MDS1284 MDS1285 MDS1286 MDS1287
Sensicare Free PF Nitrile with Microstop*
2,000 ea /1,800 ea XL
MDSFREE-XS MDSFREE-S MDSFREE-M MDSFREE-L MDSFREE-XL
Sensicare Ice PF Nitrile with Microstop*
2,000 ea /1,800 ea XL
486800 486801 486802 486803 486804
Sensicare Silk PF Nitrile with Microstop*
2,000 ea /1,800 ea XL
MDS9083 MDS9084 MDS9085 MDS9086 MDS9087
MediGuard Blue PF Nitrile*
2,000 ea /1,800 ea XL
EM5050 EM5051 EM5052 EM5053 EM5054
Sterile Procedure Nitrile PF
300 pairs — MDS2294 MDS2295 MDS2296 MDS2297
VIN
YL
Curad 3G PF Vinyl* 1,000 ea / 900 ea XL
CUR8233 CUR8234 CUR8235 CUR8236 CUR8237
Accutouch PF Vinyl 1,000 ea MDS192073 MDS192074 MDS192075 MDS192076 MDS192077
Vinyl Synthetic PF* 1,500 ea /1,300 ea XL
MGE323 MGE324 MGE325 MGE326 MGE327
LATE
X
Curad PF Latex* 1,000 ea /900 ea XL
CURE8103 CURE8104 CURE8105 CURE8106 CURE8107
Sterile Procedure Latex PF
300 pairsr/cs
— MDS8114 MDS8115 MDS8116 MDS8117
ITEM IN
DEX
* The majority of the Medline portfolio is PPE certified to ensure extra protection for the user.
Page 9 Page 8
DEPA
RTM
ENTS
GLOVES BY DEPARTMENTIntensive and Critical Care UnitsClinicians in intensive and critical care units require gloves that can withstand longer wear times in a high demand environment.
NITRILE VINYL
HOUSEWIDE THICK SENSITIVE 3G 1G
General patient care a
Non-Critical Care UnitsClinicians in units such as med-surg, radiology, respiratory and physical therapy typically perform procedures that do not place significant levels of stress on examination gloves. Facilities have greater flexibility in the selection of exam gloves for these areas.
NITRILE VINYL
HOUSEWIDE THICK SENSITIVE 3G 1G
General patient care a a a a
Emergency DepartmentClinicians in the emergency department need gloves that are strong enough to withstand rigorous tasks. Gloves must allow for longer wear times while protecting against heavy fluids, unknown elements and high-stress situations.
NITRILE VINYL
HOUSEWIDE THICK SENSITIVE 3G 1G
General patient care a a
Labour and Delivery Clinicians in the L&D department need gloves that allow for longer wear times while protecting against heavy fluids, unknown elements and high-stress situations.
NITRILE VINYL
HOUSEWIDE THICK SENSITIVE 3G 1G
Gloves not made with natural rubber latex
a a
Sterile procedures a
Operating Room Operating room personnel use exam gloves for a variety of tasks, including room turnover, sponge counts, pre/post op and anaesthesia.
PhlebotomyPhlebotomists need gloves with excellent tactile sensitivity to allow them to find veins hidden beneath the skin.
NITRILE VINYL
HOUSEWIDE THICK SENSITIVE 3G 1G
Strong chemical resistance a a
Greater grip requirements a a a
Comfort a a a a
Resistance to chemotherapy agents a a a
Durability a a
Tactile sensitivity a a a
NITRILE VINYL
HOUSEWIDE THICK SENSITIVE 3G 1G
Excellent tactile sensitivity a
Pharmacy/Oncology Chemotherapy-tested nitrile gloves are required for clinicians who are preparing, compounding, handling or administering harsh chemotherapy drugs.
NITRILE VINYL
HOUSEWIDE THICK SENSITIVE 3G 1G
Resistance to chemotherapy agents a a a
Environmental Services Environmental services employees may handle harsh chemical cleaning compounds and ideally should use nitrile gloves, which provide the most effective chemical resistance of all glove materials.
NITRILE VINYL
HOUSEWIDE THICK SENSITIVE 3G 1G
Strong chemical resistance a a
Sterile Processing Sterile processing techs clean, decontaminate, disinfect and sterilise surgical instrument packs. These activities require thick gloves that can stand up to harsh chemicals and added stress.
NITRILE VINYL
HOUSEWIDE THICK SENSITIVE 3G 1G
Strong chemical resistance a
Laboratory Laboratory clinicians have a variety of glove needs. Some work with harsh chemicals that require gloves with greater chemical resistance, and others need gloves with greater grip requirements that perform well in both wet and dry situations.
NITRILE VINYL
HOUSEWIDE THICK SENSITIVE 3G 1G
Resistance to chemotherapy agents
a a a
Page 11 Page 10
PROP
ERTI
ES
GLOVE PROPERTIESViral PenetrationThe viral penetration test determines if a glove provides an effective barrier against one of the smallest measurable viruses in the world, phi-X174. If the glove is a barrier to the phi-X174 virus, it also provides a barrier against larger viruses. All of Medline's exam gloves have passed the viral penetration test. Chemical Resistance and Barrier Guide Medline exam gloves are tested to a wide range of chemicals and chemotherapy drugs. For a full list of test results please contact your sales representative.
Rating CodeThe basis of the rating code is breakthrough time in minutes only. We have colour-coded the ratings for your convenience.
Permeation rate measured in μg/cm2/minute. Test data on file. ASTM F739, Standard Method for Determining Resistance to Chemical Permeation Under Conditions of Continuous Contact. EN 374: European Standard for Glove Resistance To Permeation by Chemicals.
RECOMMENDED CAUTION NOT RECOMMENDED NOT TESTED
Breakthrough occurs at 60 minutes or after. This glove is well suited for application with this chemical.
Breakthrough occurs in 30 to 59 minutes. This glove is suitable for this chemical under careful control of its use.
Breakthrough occurs in less than 30 minutes. Avoid use of the glove with this chemical.
RESTORE NITRILE CURAD PF 3G STRETCH VINYL ALOETOUCH 12" NITRILE SENSICARE ICE PF NITRILE SENSICARE SILK
Test
Use
d
Conc
entr
atio
n
Brea
kthr
ough
(m
in.)
Test
Use
d
Conc
entr
atio
n
Brea
kthr
ough
(m
in.)
Test
Use
d
Conc
entr
atio
n
Brea
kthr
ough
(m
in.)
Test
Use
d
Conc
entr
atio
n
Brea
kthr
ough
(m
in.)
Test
Use
d
Conc
entr
atio
n
Brea
kthr
ough
(m
in.)
1-Propanol, 70% EN374-3 70% 24.2 EN374-3 70% 17.4 EN374-3 70% 16.7
Accelerated Hydrogen Peroxide (0.5% or higher)/ OXIVIR TB
ASTM F 739 1.7 EN 374-3 0% 7.3 ASTM F 739 30.2 ASTM F 739 15 ASTM F 739 10
Acrylamide 40% ASTM F 739 40% >480
Ammonium Chloride, Saturated
ASTM F 739 Saturated >480 EN 374 -3 Saturat-ed
>480 EN 374 -3 Saturated >480
Ammonia Hydroxide ASTM F 739 28% 63.1 EN 374-3 25% <10 ASTM F 739 28% 65.4 ASTM F 739 28% 99.3 ASTM F 739 28% 22
Benzene ASTM F 739 0 ASTM F 739 0
CaviWipes XL (Isopropanol 14.3% and Ethylene Glycol Monobutyl Ether 2.49%)
ASTM F 739 50 ASTM F 739 180 ASTM F 739 120 ASTM F 739 26.7
Cetrimide, 1% ASTM F 739 1% >480
Chlorhexidine Gluconate
EN 374 -3 4% >480
Chlorhexidine Digluconate
ASTM F 739 4% >480 ASTM F 739 4% >480 ASTM F 739 4% >480 ASTM F 739 20% >480
Chlorhexidine Digluconate
ASTM F 739 20% >480 ASTM F 739 20% >480
Cidex 14-Day ASTM F 739 OPA 262.3
Citric Acit, Saturated Solution
EN374-3 Saturated >480 EN 374 -3 Saturated >480 EN374-3 Saturated >480
Citric Acid 70% ASTM F 739 70% >480 ASTM F 739 >480 ASTM F 739 70% >480
Clorox Bleach ASTM F 739 >480 ASTM F 739 >480 ASTM F 739 >480 ASTM F 739 >480
Cyclohexanol (Hexanol) ASTM F 739 99% 130.6 EN 374-3 100% <10 ASTM F 739 >480
Ethanol EN374-3 70% 16.8 ASTM F 739 85% 10.7 EN374-3 70% 13.8
Ethanolamine, 99% EN374-3 99% >480 EN 374 -3 99.0% >480 EN374-3 99% >480
Ethidium Bromide ASTM F739 Saturated >480 EN 374 -3 1% >480 ASTM F 739 >480
Ethylene Glycol, (PEG-8) ASTM F 739 >480
Formalin ASTM F739 >480 ASTM F 739 >480
Formalin 10% buffered (which is 4% formaldehyde)
EN 374 -3 10% >480 ASTM F 739 10% >480
Formaldehyde 5% ASTM F 739 5% >480 ASTM F 739 5% >480
Formaldehyde, 37% EN374-3 37% >480 EN 374-3 37% <10 ASTM F 739 >480 EN 374-3 37% >480 EN374-3 37% >480
Glutaraldehyde ASTM F 739 5% >480 EN 374 -3 3% >480 ASTM F 739 5% >480 ASTM F 739 5% >480
Glutaraldehyde, 50% EN374-3 50% 21.8 EN 374-3 50% >480 EN374-3 50% >480
Hexane, 99% EN374-3 99% 9 EN 374-3 99% >480 EN374-3 99% 18.7
RESTORE NITRILE CURAD PF 3G STRETCH VINYL ALOETOUCH 12" NITRILE SENSICARE ICE PF NITRILE SENSICARE SILK
Test
Use
d
Conc
entr
atio
n
Brea
kthr
ough
(m
in.)
Test
Use
d
Conc
entr
atio
n
Brea
kthr
ough
(m
in.)
Test
Use
d
Conc
entr
atio
n
Brea
kthr
ough
(m
in.)
Test
Use
d
Conc
entr
atio
n
Brea
kthr
ough
(m
in.)
Test
Use
d
Conc
entr
atio
n
Brea
kthr
ough
(m
in.)
Hydrochloric Acid, 35% ASTM F 739 130.7 ASTM F 739 35% 165.8 ASTM F 739 35% 81
Hydrochloric Acid, 10% ASTM F 739 10% >480 ASTM F 739 10% >480
Hydrazine Solution, 35%
ASTM F 739 35% 137.8 ASTM F 739 164.9 ASTM F 739 35% 144.2 ASTM F 739 35% 180
Hydrogen Peroxide, 30%
ASTM F 739 30% 27.8 EN 374 -3 30% >480 ASTM F 739 22.9 EN 374-3 30% 19 ASTM F 739 30% 100
Instrument Stain remover (MDS88000T5-Medline Instrument Stain remover)
ASTM F 739 >480
Instrument Lubricant Super Concentrate (active ing. Surfactant & Propylene Glycol 57-55-6) (MDS88IL25CM- Medline Instrument Lubricant Super Concentrate)
ASTM F 739 >480
Isopropyl Alcohol 70% EN374-3 70% 38 EN 374-3 70% 4.8 ASTM F 739 48.9 EN 374 -3 70% 32.8 EN374-3 70% 29.1
Isopropanol 70% EN374-3 70% 29.1
Lidocaine Hydrochloride Jelly USP, 2%
ASTM F 739 2% >480 ASTM F 739 2% 69.2 ASTM F 739 57
Micro-Kill One Germicidal Alcohol Wipes (Ethyl Alcohol 72.50%)
ASTM F 739 0 ASTM F 739 60.3 ASTM F 739 20.4 ASTM F 739 20.3
n-Heptane EN 374-3 10 EN 374-3 >120 EN 374 -3 <10 EN 374-3 100% 0
Nitric Acid, 10% ASTM F 739 55.4
Osmium Tetroxide EN 374 -3 2% >480 ASTM F 739 2% >480
Oxivir Tb Wipes (ing. is Benzyl alcohol 1-5%)
ASTM F 739 1.7 ASTM F 739 30.6 ASTM F 739 15 ASTM F 739 15
Peracetic Acid, 5% ASTM F 739 5% 101.2 ASTM F 739 5% 191.7
Phosphoric Acid, 85% ASTM F 739 >480
Potassium Hydroxide ASTM F 739 Saturated >480 EN 374-3 30% >480 ASTM F 739 >480 ASTM F 739 30% >480
Povidone Iodine 10% ASTM F 739 10% >480 EN 374 -3 10% >480 ASTM F 739 >480 ASTM F 739 10% >480 ASTM F 739 10% >480
Quaternary Cleaners EN374-3 >480 EN 374 -3 >480 ASTM F 739 173 EN 374 -3 >480 EN374-3 >480
Super Sani-Cloth Germicidal Disposable Wipe
ASTM F 739 26.7 x ASTM F 739 80 ASTM F 739 100.1
Sterillium (Ethyl Alcohol 85%)
ASTM F 739 85% 0 ASTM F 739 40.1 ASTM F 739 0.8 ASTM F 739 0.5
Sodium 2-Ethylhexyl Sulfate, 50% in H2O
EN374-3 181.5 EN 374-3 195.6 EN 374-3 173.4
Sodium Carbonate, saturated
EN374-3 Saturated >480 EN 374-3 Saturated >480 EN 374-3 >480
Sodium Hydroxide, 50%
ASTM F 739 50% >480 EN 374 -3 40% & 50%
>480 ASTM F 739 >480 ASTM F 739 50% >480 ASTM F 739 50% >480
Sodium Hypochlorite 10-13% (Clorox Bleach)
EN 374-3 10-13% >480 ASTM F 739 >480 EN 374 -3 10-13% >480 ASTM F 739 10-13% >480
Sulfuric Acid 50% ASTM F 739 50% >480 ASTM F 739 50% >480 ASTM F 739 50% >480
Tide Liquid Laundry Detergent (Fatty Alochol Ethoxylate)
EN374-3 >480 EN 374-3 >480 EN 374-3 >480
Tetrahydrofurane EN 374-3 0 EN 374-3 0 EN 374-3 0 EN 374-3 100% 0
Toluene EN 374 -3 100% 0 EN 374-3 0 EN 374-3 0 EN 374-3 100% >480
Triclosan ASTM F739 >480 ASTM F 739 >480 ASTM F 739 >480
Xylene ASTM F 739 99% 0 ASTM F 739 0 ASTM F 739 99% 0
We reserve the right to correct any errors that may occur within this brochure. ©2017 Medline Industries, Inc. Medline is a registered trademark of Medline Industries, Inc. ML461-EN01/JK 02/2017.
FOLLOW US BLOG
Medline Industries Ltd No 5 Booths Park Chelford Road Knutsford, Cheshire WA16 8GSEnglandTel: +44 844 334 5237 Fax: +44 844 334 5238www.medline.com/[email protected]
For more information on our products, please contact your Medline sales representative or visit our site www.medline.com/uk.
Medline is dedicated to high quality product and high quality service by all means possible. Being a topmanufacturer and distributor of exam gloves in the world, Medline can provide the below guarantees soyou know your caregivers hands are in good hands.
Medline Guarantees:• 99% service level in Europe• Large global infrastructure allows for quick response in times of health emergency which cause sharp
increases in demand • Manufacturing the right way o All plants are EN ISO13485 certified to maintain consistency in product quality o All plants undergo regular social responsibility audits to ensure employee well being