innovative motion products european technology for business ltd, codicote innovation centre, st....

19
INNOVATIVE MOTION PRODUCTS European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438 822822 Web: www.etb.co.uk Diana Hodgins European Technology for Business Ltd Using information on how a person walks to keep them healthy and active

Upload: alexander-powers

Post on 28-Dec-2015

220 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: INNOVATIVE MOTION PRODUCTS European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438

INNOVATIVE MOTION PRODUCTS

European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438 822822 Web: www.etb.co.uk

Diana HodginsEuropean Technology for Business Ltd

Using information on how a person walks to keep them healthy and active

Page 2: INNOVATIVE MOTION PRODUCTS European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438

INNOVATIVE MOTION PRODUCTS

European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438 822822 Web: www.etb.co.uk

What to measure

Measure how a person walks (their gait) in their natural environment.

This provides an objective measurement which can be compared to a healthy subject.

Page 3: INNOVATIVE MOTION PRODUCTS European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438

INNOVATIVE MOTION PRODUCTS

European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438 822822 Web: www.etb.co.uk

Applications

• Diagnosis of knee or hip problems or gait disorders.

• Monitoring the rehabilitation process after injury, identifying when a normal gait is restored, including sports injuries.

• Identify people at risk of falling due to an unstable gait.

• Setting prosthesis.

Page 4: INNOVATIVE MOTION PRODUCTS European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438

INNOVATIVE MOTION PRODUCTS

European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438 822822 Web: www.etb.co.uk

What is Gait Monitoring?• Information about how you move when walking

– Stride duration – Knee flexion angle – Range of Motion (RoM)– Thigh and calf movement – Adduction/ abduction & RoM– Asymmetry between the left and right leg

• Can be performed when

– On level ground, for example in a corridor– On slopes, gravel, different surfaces etc– On stairs

Page 5: INNOVATIVE MOTION PRODUCTS European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438

INNOVATIVE MOTION PRODUCTS

European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438 822822 Web: www.etb.co.uk

The portable system

Four small, light (54g) sensors

Each contain 3 gyroscopes and a 3-axis accelerometer

Store data for immediate analysis after the test

Page 6: INNOVATIVE MOTION PRODUCTS European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438

INNOVATIVE MOTION PRODUCTS

European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438 822822 Web: www.etb.co.uk

How the sensors are attached

Page 7: INNOVATIVE MOTION PRODUCTS European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438

INNOVATIVE MOTION PRODUCTS

European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438 822822 Web: www.etb.co.uk

The system in use at a Day centre

Page 8: INNOVATIVE MOTION PRODUCTS European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438

INNOVATIVE MOTION PRODUCTS

European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438 822822 Web: www.etb.co.uk

Key gait measurements

• Stride duration (mean and variability)Increases for people with a problem walking

• Knee flexionReduces for those with a problem walking

• Difference in knee flexion between the left and right

Increases for people with a problem with one leg or hip

Page 9: INNOVATIVE MOTION PRODUCTS European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438

INNOVATIVE MOTION PRODUCTS

European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438 822822 Web: www.etb.co.uk

Key gait measurements

• Abduction/ adductionPuts incorrect loading on joints, alters balance

• Flexion on loadReduces for those with knee OA

• Difference in thigh or calf between the left and right

Identifies where the problem is

Page 10: INNOVATIVE MOTION PRODUCTS European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438

INNOVATIVE MOTION PRODUCTS

European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438 822822 Web: www.etb.co.uk

Traffic light systemHealthy people across the age range 18 to 97 have been measured.

Limits for the 14 parameters summarised from the gait cycle ascertained.

Amber and red flags given if the parameter falls outside the healthy range.

Page 11: INNOVATIVE MOTION PRODUCTS European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438

INNOVATIVE MOTION PRODUCTS

European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438 822822 Web: www.etb.co.uk

Range of Motion Score % 100.0 Left Right Range knee 63.43 58.19 Range thigh 41.13 43.58 Range calf 72.39 70.02 Average Duration (s) 1.06 Quality of Gait Score % 89.3 Calf medial-lateral (%) 50.05 40.93 Thigh medial-lateral (%) 20.16 15.24 Swing Time (%) 48.00 48.00 Stance Flexion 19.05 11.59 Symmetry Score % 100.0 Knee (%) 8.60 Thigh (%) -5.78 Calf (%) 3.33 Stance (%) 39.17 Swing Difference (%) 0.00

Example from 81 year old lady who had a stroke 18 months ago

Page 12: INNOVATIVE MOTION PRODUCTS European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438

INNOVATIVE MOTION PRODUCTS

European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438 822822 Web: www.etb.co.uk

You can have a good gait at any age

Excellent symmetry and knee flexion

Blue – left knee, Green – right knee

Attends weekly line dancing classes 73 years young

Young adult who rides horses and does kick boxing 23 years old

Excellent symmetry and knee flexion

Page 13: INNOVATIVE MOTION PRODUCTS European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438

INNOVATIVE MOTION PRODUCTS

European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438 822822 Web: www.etb.co.uk

Elderly person following a fall

Good symmetry and flexion

Poor symmetry with minimal flexion on left knee

Blue – left knee, Green – right knee

Day after a fall,using Roller frame

2 months after fall, weekly balance classes, no Roller frame

Page 14: INNOVATIVE MOTION PRODUCTS European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438

INNOVATIVE MOTION PRODUCTS

European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438 822822 Web: www.etb.co.uk

People with early stage osteoarthritisDifficult to diagnose

Pain is not a good indicator

Caught early enough can be treated with drugs or exercises rather than surgery

Improve the gait profile and reduce the pain

Page 15: INNOVATIVE MOTION PRODUCTS European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438

INNOVATIVE MOTION PRODUCTS

European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438 822822 Web: www.etb.co.uk

Profile of person with knee OA

Healthy Person – Good flexion on load Person with knee OA- Poor knee flexion on load

Page 16: INNOVATIVE MOTION PRODUCTS European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438

INNOVATIVE MOTION PRODUCTS

European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438 822822 Web: www.etb.co.uk

Work at the London Knee ClinicAll new patients are measured and findings form part of the diagnosis.

Patients are monitored during rehabilitation to ensure the knee is being correctly exercised.

Patients can see for themselves what is happening as they walk and can monitor their progress after treatment.

Page 17: INNOVATIVE MOTION PRODUCTS European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438

INNOVATIVE MOTION PRODUCTS

European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438 822822 Web: www.etb.co.uk

FindingsPeople are happy to be measured and find the results useful. It provides a goal if improvements are necessary.

Gait abnormalities occur in people of all ages and if untreated will ultimately lead to problems such as osteoarthritis.

During rehabilitation it is important that a normal healthy gait is resumed.

Page 18: INNOVATIVE MOTION PRODUCTS European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438

INNOVATIVE MOTION PRODUCTS

European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438 822822 Web: www.etb.co.uk

Our future visionGait should be monitored regularly and

abnormalities corrected by exercises where possible

All surgical intervention involving knee or hip should have a pre and post operative gait test

Sports injuries often result in asymmetric gait patterns. These should be quantified and corrected.

Every clinic treating lower limbs should have one!

Page 19: INNOVATIVE MOTION PRODUCTS European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438

INNOVATIVE MOTION PRODUCTS

European Technology for Business Ltd, Codicote Innovation Centre, St. Albans Road, Codicote, Herts SG4 8WH, UK Tel: +44 (0)1438 822822 Web: www.etb.co.uk

Thank youTo all the people that have happily volunteered to

be monitored

To the London Knee clinic and Longmead Day Centre for providing real case study examples

Diana Hodgins [email protected]

00 44 1438 822822