    INSTALLATION MANUAL

    E-II-YDS-C-0907

    DIGITAL SCROLL CENTRAL AIR CONDITIONER (OUTDOOR UNIT) YDS SYSTEM R410A

    For correct installation, read this manual before starting installation.Only trained and qualified service personnel should install, repair or service air conditioning equipment. Users

    should not install the air conditioner by themselves. All pictures are only sketches. If there is any difference between pictures in this manual and the actual shapeof the air conditioner you purchased, the actual shape shall prevail.

    YDMH-252C35B

    YDMH-280C35B

    YDMH-335C35B

    YDMH-400C35B

    YDMH-450C35B

    Model:

  • 7/27/2019 Inst Manual Outdoor252 450C

    2/12

    INSTALLATION LOCATION

    Outdoor unit installation manual

    OutlineName

    1

    2

    FunctionQty.

    90 elbow

    Hole site for fork lift Chassis

    1

    1

    1

    1

    1

    2

    PRECAUTIONS

    1. This installation manual is for the outdoor unit.2. Refer to the indoor unit installation manual for indoor parts

    installation.3. Please read the power source unit installation manual to

    install the power source unit .4. Please refer to the refrigerant distributor installation

    manual to install the refrigerant distributor.

    KEY POINTS IN INSTALLATION

    INSTALLATION

    Confirm the model and name of your air conditioner to avoid installation mistakes.

    REFRIGERANT PIPING

    Separately purchased refrigerant distributor (branch joint, branch header pipe) should be used in the processof refrigerant piping.

    Charge nitrogen under certain pressure in the refrigerantpiping before welding.Heat insulation should be done to refrigerant piping.

    After the installing refrigerant piping, do not electrify theindoor unit before the airtight test and vacuum.

    Refrigerant piping should accord with specifieddiameter.

    AIRTIGHT TEST

    Refrigerant piping must be tested for gas proof 2[3.8MPa(40kgf/cm ) nitrogen.]

    VACUUM

    Vacuum pump must be used, and vacuuming shouldbe done from the gas side and liquid side

    simultaneously.ADD REFRIGERANT

    When the actual pipe is longer than the fiducial length,the added refrigerant volume of every outdoor unitdepends on the calculating according to the actual length.Fill the form on the outdoor unit electric control box withthe added volume, length of pipes (actual length) and therelative height drop between outdoor unit and indoor unit.

    WIRING

    Choose power capacity and wire diameter according tothe design manual. The power cord of the air conditioner

    should be wider than the power cord of ordinary motor.

    Connect the indoor unit to the power after airtight testand vacuuming.

    Do not twist or cross the power cord (380V 3N~)withwiring (low voltage) between indoor and outdoor unit, or mishandling may occur.

    Set the address of outdoor unit, see Address dialof outdoor unit

    TEST RUNNING

    The test running can not begin until the outdoor unit hasbeen connected to the power for 12hr.

    Remove six sponges at the back of unit. Please handlewith care to avoid damage to fin, which will decreaseheat exchanging efficiency.

    1. Please keep away from the following place, or malfunction of the machine may be caused:

    2. The insulation of the metal parts of the building and theair conditioner should comply with the regulation of National Electric Standard.

    CAUTION

    There is combustible gas leakage.There is much oil (including engine oil) ingredient.

    There is salty air surrounding(near the coast)There is caustic gas (the sulfide) existing in the air (near a hotspring).

    A place the heat air expelled out from the outdoor unitcan reach your neighbor's window.

    A place that the noise interferes your neighbors everyday life.

    A place that is too weak to bear the weight of the unit.Uneven place.Insufficient ventilation place.Near a private power station or high frequency equipment.

    A place with strong electromagnetic interference.

    ACCESSORIES (Outdoor unit)

    Outdoor unit owner s manual

    Indoor unit owner s manual

    Service manual(guaranteeand bar code inside)

    Screw bag

    Straight screwdriver

    (Given to users)

    (Given to users)

    (Given to users)

    This manual

    Spare

    Dialling

    For airtight test

    Pipe connecting

    Gauge joint

    CARRY IN THE OUTDOOR UNIT

    Sling the outdoor unit and carry it in with 4 steel wire( 6mm or more)Use soft board to protect the unit surface from scratchand distortion where contact the steel wire.Remove the transportation board after carrying in theoutdoor unit.

    1. Carry in with steel wire:

    2. Carry in with a fork lift

    Protection board

    Steel wire

  • 7/27/2019 Inst Manual Outdoor252 450C

    3/12

    Mode Qty. of indoor unit

    (Air-in )

    (Air-out )

    Outdoor unit planform

    Installation and maintenance surface

    1000mm

    1000mm 100mm~ 500mm 1000mm

    1000mm

    2. When there is obstacle above the outdoor unit:

    A

    B

    C

    D

    45

    1000mm

    Airflow deflecto r

    Front view

    B

    A

    B

    A

    C

    D

    Side view

    B

    A

    100mm~ 500mm

    INSTALLATION SPACE

    1. Leave enough space for maintenance (see followingpicture) and install power unit on the side of outdoor unit. Refer to power unit installation manual.

    2. Keep the modules in one system at the same level.

    (Air-in )

    300mm

    Front view Front view

    NOTE: The top of any pile around the outdoor unit should at least 800 mmbelow the top of unit. If not, plea se install mechanical air discharge equipment.

    REFRIGERANT PIPE

    1. Refrigerant piping connection is inside the outdoor unit, please remove the front clapboard.

    2. The piping can be led through the down-left of theoutdoor unit or the soleplate gap.

    3. When through the front, piping is led by wiring fromthe panel, then connect branch pipes towards leftor right.

    4. When through the soleplate gap, install the branchpipe towards left, right or back.

    5. If through the front, please remove the clapboardat corresponding place first.

    To prevent the inside of piping from oxidizingwhen welding, it is necessary to charge nitrogen,or oxide may block the circulation.

    CAUTION

    OUTDOOR UNIT COMBINATION

    Mode Qty. of indoor unit

    To gas balance pipe

    To gas side pipe

    Low-pressureball valve

    NOTE: No connectionwith gas and oil balancepipes for single module.

    1

    2

    3

    Refer to Number 1 in picture below

    Pipe between outdoor unit and the firstbranch (Main pipe)

    Size of main pipe connecting multi-modulesNumber 2 in picture below

    Pipe between branchesNumber 3 in picture below

    PIPE SIZE AND CONNECTION

    1 23

    2 2 2 2 23 3 3 3 3 3 3

    1

    33 3 3

    1 2 2 2 2

    3 3 3 33 3

    1

    2

    3

    33

    Outdoor unit

    Outdoor unit

    Outdoor unit

    Single module

    Gas pipe

    Liquid pipe

    NOTE: Pipe size of model 8HP, 10HP and 12HP:liquid side 12.7, gas side 25.4.Pipe size of model 14HP and 16HP:liquid side 15.88, gas side 35.0.

    No connection with gas balance pipes for single module.

    To liquid side pipe

    To gasbalance pipe(Flaring nut)

    (Flaring nut)

    (Flaring nut)

  • 7/27/2019 Inst Manual Outdoor252 450C

    4/12

    Gas balance pipe 1, 15.9Gas balance pipe 2, 19.0

    C onnection of gas b alance pipes

    C onnection of g as balance pipes

    capacity

    capacity

    Four modulescapacity

    Liquid pipe 25

    Gas p ipe 54 Th ree modulescapa city

    Two modules

    YDMH-252C35BYDMH-280C35BYDMH-335C35BYDMH-400C35BYDMH-450C35B

    YDSA/RD101YDSA/RD101YDSA/RD101YDSA/RD102YDSA/RD102

    YDSA/RD102

    YDSA/RD102YDSA/RD01

    YDSA/RD103

    YDSA/RD103YDSA/RD104YDSA/RD104

    NOTE: Wrap the valveswith wet cloth when welding,or the valves may bedamaged to cause leakage.

    C onnection of g as balance pipes

    S ee following chart for size o f T-shaped pipes Zconnecting with ga s pipe.

    3- 19.0

    (Table2) Pipe size andconnection of single modult andBranch joint

    Main pipe(gas sid e/liquid side)

    (Table3) Size of Multi-T aiwan pipe and branch pipe

    Branch joint

    Note: the distance between a outdoor unit and the otherwhich is farthest from it is less than 90 meters.The mainpipe may be the smaller level.

    Branch joint Liquid side Y Three Contacts A:

    I n s

    i d e

    d i a m e t e r

    I n s

    i d e

    d i a m e t e r

    I n s

    i d e

    d i a m e t e r

    I n s i

    d e

    d i a m e t e r

    I n s i

    d e

    d i a m e t e r

    Gas side Y Three Contacts B:

    I n s

    i d e

    d i a m e t e r

    I n s

    i d e

    d i a m e t e r

    I n s

    i d e

    d i a m e t e r

    I n s i

    d e

    d i a m e t e r

    I n s i

    d e

    d i a m e t e r

    Gas s ide Y type three Contacts above :Gas/liquid side

    Gas/liquid side

    Z

    18

    32

    32

    Y

    Gas balanc e pipe 1, 15.9Gas balance pipe 2, 19.0

  • 7/27/2019 Inst Manual Outdoor252 450C

    5/12

    1 2

    10

    3 4 5 6 7

    11 12 13 14 15 16 1817

    L N

    a b8 9c d e f g h i j

    12HP 16HP16HP

    #1( 5P ) ( 5P ) ( 5P ) ( 5P ) (5P ) (5P )

    #2 #3 #4 #5 #6 #7(5P ) (5P ) (4P )

    #8 #9

    M

    150m

    175m

    40 m

    70 m

    40 m

    15 m

    L1+L2+L3+L4+L5+L6

    L1+L3+L4+L5+L6+i

    L3+L4+L5+L6+i

    +a+b+c+d+e+f+g+h+i30HP 3 5 0 m

    5 0 0 m30HP

    Table 4Size of main pipe

    A: Cap aci ty of all the indoo r uni ts. A(horsepower) A 1212 A 1616 A 2828 A 3434 A 4848 A 64

    22.0 / 9.53

    Take (16+16+12)HP outdoor unit as example:

    parallel outdoor unit:

    1. Branch pipes: NoL,M,N the size is 25.0/ 12.7 / 15.9 35.0/According to the cor respondin g outdoor units ability.

    2..1# pipe , total HP is 16+12=28HP pipe size is 0/

    3.model of branch joint: a ,type YDSA/RD101 ,b choose YDSA/RD01.Room inside:

    1). Branch pipes are 10--18,refer to table 5,the size is: 15.9/ 9.532). Subordinate indoor units of pipe 9 are 8#, 9#, total HP is 5+4=9P 12P

    , pipe 9# size is 22.0/ , model of branch joint j :YDSA/RD101

    3). Subordinate indoor units of pipe 8 are 7#,8#,9#, totel HP is 5+5+4=14P

    16P,pipe size is / 12.7, model of branch joint I : YDSA/RD102

    4).Subordinate indoor units of pipe 7 are 6#~9#, totel HP is 5+5+5+4=19P

    28P,pipe size is 35.0/ , model of branch joint h : YDSA/RD102

    5).Subordinate indoor units of pipe 6 are 5#~9#, totel HP is5+5+5+5+4=24P 28P

    pipe size is 35.0/ , model of branch joint g ::YDSA/RD102

    6).Subordinate indoor units of pipe 5 are 4#~9#, totel HP is5+5+5+5+5+4=29P

    34P,pipe5 size is .0/ , model of branch joint f ::YDSA/RD102

    7).Subordinate indoor units of pipe 4are 3#~9#, totel HP is5+5+5+5+5+5+4=34P

    34P,pipe4size is .0/ , model of branch joint e :: YDSA/RD102

    8).Subordinate indoor units of pipe 3are 2#~9#, totel HP is5+5+5+5+5+5+5+4=39P

    48P,pipe3size is .0/ , model of branch joint d :: YDSA/RD103

    9).Pipe2 is the main pipe,the size of pipe2 and branchc refer to the outdoor unit.

    pipe3size is .0/ model of branch j oint c ::YDSA/RD103

    9.5312.7

    0.060kg0.110kg

    19.022.0

    0.250kg0.350kg

    25.0 0.520kg

    15.9 0.170kg

    28.6 0.680kg

    Main pipe(gas side/liquid side) Branch joint

    Note: the first branch pipe is according to the total ability of theoutdoor unit, the others could not larger than it.

    Length and Drop Height Permitted of the R efrigerant piping

    Permitted value

    Total Pipe Length (Actual)

    Max Piping (L)

    Indoor Unit to Indoor Unit Drop Height(h)

    Indoor-Outdoor UnitDrop Height(H)

    Piping (farthestfrom the first linepipebranch) Equivalent Length (l)

    Actual LengthEquivalent Length

    Outdoor Unit UpOutdoor Unit Down

    P i p e

    L e n g

    t h

    D r o p

    H e

    i g h t

    Piping

    Make sure there is no any dirt or water beforeconnecting the piping to the outdoor units.Wash thepipingwith high pressure nitrogen,neveruserefrigerant of theoutdoor unit.

    Remove Dirt or Water in the Piping

    Airtight Test1. C onnect piping on h i-pressur e sid e with hi-pressur e

    va lve. (For multi-modules pa rallel connection, pleaseco nnect gas and oil balance v alves.)

    2. W eld the piping on l ow-press ure s ide with gauge joint.3. C harge nitrogen from hi-pressur e va lve c ore a nd gaugejo int.

    4. After airtight test, weld low-pressur e ba ll valve a ndpiping on low--pressur e side.

    CAUTION21.Pres sured n i trogen [3.8MP a (40kg /cm ) shou ldbeu sed in the

    air tigh t test.

    3. The air tight test should never use any ox ygen, f lammablegasor po isonous gas.

    2. Do not c onnect piping on low-pressure s ide and low -pressure ballvalve be fore charg ing nitrogen.

    4. W rap low-press ure valve and balance valves w ithwet cloth while welding.

    Do vacuum with vacuum pump instead of refrigerant.

    Vacuum with vacuum pump

    Vacuuming should be done from liquid and gas sidesimultaneously. The pressure should be lower than30Pa.

    Open all valves

    Refrigerant Amount to be AddedCalcu late the added ref rigerant according to the diameterand the length of the liquid sidep ipe oftheou tdoor/indoorunit connection. T he refrigerant is .R410A

    Pipe siz e on liquid s ide Re frigerant to be Added per meter6.35 0.022kg

    Table5size and connection of branch pipes

    Note:Y type branch joint a,b must be the level laying ,otherwise can causethe cold intermediary assignment to be uneven!And multi-Taiwan paralleloutdoor unit must be in the identical altitude.

    Gas balance valve

    Hi-pressure valve

    Gauge joint

    Indoor unit and branch joint

    Low-pressure valve

    Outdoor Unit (one or more outdoor units)

    D

    r o p H e i g h t b e t w e e n I n d o o r

    u n i t a n d o u t d o o r U n i t H

    7 0 m

    First branch

    Indoor Unit

    Max Piping EquivalentLength L 125m7

    (From the first branch)Max piping EquivalentLength l 40m

    Indoor Unit

    I n d o

    o r

    U n

    i t t o I n d

    o o r

    U n

    i t

    D r o p

    H e

    i g h t

    Gas balance valve

    YDSA/RD101YDSA/RD101YDSA/RD102YDSA/RD102YDSA/RD103YDSA/RD103

    28 ~ 45 (4-way cassette)

    56 ~ 112 (4-way cassette)

    22 ~ 36 (duct type) / ceiling de floor

    45 ~ 71 (duct type)

    22 ~ 56 (wall mounted)

    12,7 (Flaring nut)

    16,0 (Flaring nut)

    12,7 (Flaring nut)

    16,0 (Flaring nut)

    12,7 (Flaring nut)

    6,35 (Flaring nut)

    9,53 (Flaring nut)

    6,35 (Flaring nut)

    9,53 (Flaring nut)

    6,35 (Flaring nut)

    R410A

    / ceiling de floor

    28.6 / 12.7 35.0 / 15.9 38.0 / 19.0 42.0 / 22.0 45.0 / 22.0

  • 7/27/2019 Inst Manual Outdoor252 450C

    6/12

    QUERY DESCRIPTION

    Address dial of outdoor unit

    The address dial of outdoor unit is shown below:when outdoor unit is on,namely examines outdoor scheme quantity, and determines the main unitor auxiliary unit according to outdoor unit address.

    Address 0: outdoor main unit; Address 1: outdoor auxiliary unit; Address 2: outdoor auxiliary unit; Address 3: outdoor auxiliary unit; Address higher than 3: ineffective address, error occurs.

    Distance between ground bolt is shown below: (Note: Outdoor units inthe same system should be located in the same level.)

    Outdoor unit

    Through hole(15X20 longhole)

    Sw4 query instructions:Display content Note

    Normal displayNormal display ADDR of outdoor unitCap. of outdoor unitQty. of outdoor unitTotal cap. of outdoor unitsCap. REQT. of indoor unitsCap. REQT. of main unit (after correction)Running mode Actual running cap. of outdoor unitFan speed

    Discharge temp, inverter compressor Discharge temp, No.1 fixed compressor Discharge temp, No.2 fixed compressor Current, inverter compressor Current, No.1 fixed compressor Current, No.2 fixed compressor Opening degree, electronic expansion valveAOpening degree, electronic expansionvalveBQty. of indoor unitThe last error or protection code

    T2 averageT3 pipe tempT4 ambient temp

    Actual value Actual value Actual value Actual value Actual value Actual value Actual value Actual value Actual value

    Actual value

    Actual value 8 Actual value 8

    Effective to main unit

    Effective to main unitEffective to main unit

    No protection or error, display 00End of query

    table2 functional description

    Current protector, used for Digital Scroll compressor

    Current protector, used for No.2 fixed compressor (Reserved )

    Current protector, used for No.1 fixed compressor

    Reserved

    Transformer input, 220V AC

    Reserved

    Reserved

    load output

    Electric expansion valve drive port

    Electric expansion valve drive port

    Communication between indoor/outdoor units, RS-485 signal

    T3 sensor port

    Low pressuredetect portHigh pressure detect port

    No.1 Fixed compressor discharge temperature detect port

    Reserved

    communication between outdoor units, RS-485 signal

    T4 sensor port

    Transformer output

    load output

    Digital scroll compressor discharge temperature detect port

    Digital scroll compressor discharge temperature detect port

    Phase C Power

    load output

    Reserved

    Reserved

    Reserved

    No.2Fixed compressor discharge temperature detect port

    Please establish the address of indoor and outdoor unit before debugging!!!High-voltage in the electrically controlled box,do not move if not professional!!!

    Normal display:Display qty. of indoor units which communicate with outdoor unit onstandby mode. In case of cap. requirement, display running frequencyof compressor.Running mode:OFF: 0--OFF,1--FAN, 2-- COOL, 3-- HEAT, 4-- Constraint cool

    Fan speed: 0--OFF, 1-- LOW, 2--HIGH

    PWV opening: pulse count=displayed value 8

    Sw1, Sw2: network ADDR setting switchSw4: query button

    The outdoor unit of 8Hp, 10Hp and 12Hp exclude the part in broken

    line circle and relevant wiring (including the wiring with CT2 currentinductor and HEAT2) on nameplate.

    Sw3: constraint cool buttonSw5:Set lock mode switch

    Patternlocking

  • 7/27/2019 Inst Manual Outdoor252 450C

    7/12

    2 2 0 9 5 5 0 1 7 8

    O u t d o o r A d d r e s s

    d i a l s w i t c h

    O u t d o o r P o w e r

    d i a l s w i t c h

    M o d e L o c k

    d i a l s w i t c h

    F o r c e d

    c o o l i n g

    P o i n t

    C h e c k

    ( T a

    b l e 2 )

  • 7/27/2019 Inst Manual Outdoor252 450C

    8/12

    ( R e s e r v e

    d )

    D i g i t a l c o m p r e s s o r

    F i x e

    d c o m p r e s s o r

    F a n

    C a p a c

    i t o r ,

    f a n

    M a i n

    4 - w a y v a

    l v e

    A u x

    i l . 4 - w a y v a

    l v e

    C o n

    t a c t o r

    R e l a y

    W i r i n g p l a c e

    L o w - p r e s s u r e s w

    i t c h

    H i - p r e s s u e s w

    i t c h

    E l e c t r o n i c e x p a n s i o n v a l v e

    M i d d l e

    t e r m

    i n a l

    M i d d l e

    t e r m

    i n a l

    P i p e

    t e m p s e n s o r

    O u t

    d o o r

    t e m p s e n s o r

    d i s c

    h a r g e

    t e m p e r a

    t u r e s e n s o r ,

    D i g i t a l c o m p r e s s o r (

    i n d o o r

    )

    d i s c

    h a r g e

    t e m p e r a

    t u r e s e n s o r ,

    D i g i t a l c o m p r e s s o r ( o u

    t d o o r )

    D i s c h a r g e

    t e m p s e n s o r ,

    f i x e

    d c o m p r e s s o r

    C u r r e n t

    i n d u c t o r

    P o w e r

    t r a n s f o r m e r

    S o l e n o i

    d v a

    l v e

    C r a n k c a s e h e a t e r

    O u t

    d o o r u n

    i t C O M M e r r o r

    P h a s e p r o t e c

    t i o n

    C O M M e r r o r w

    i t h i n d o o r u n

    i t

    T 3 e r r o r w

    i t h w a r m s e n s o r

    O u

    t d o o r

    t e m p s e n s o r e r r o r

    E r r o r w

    i t h D i g i t a l d i s c h a r g e

    t e m p e r a

    t u r e s e n s o r

    O u t

    d o o r u n

    i t a d

    d r e s s e r r o r

    C h i p

    C O M M e r r o r

    C h i p

    C O M M e r r o r

    Q t y o

    f o u t d o o r u n i t d e c r e a s e s

    Q t y o

    f o u

    t d o o r u n

    i t i n c r e a s e s

    H i - p r e s s u r e p r o t e c

    t i o n

    L o w - p r e s s u r e p r o t e c

    t i o n

    C o m p r e s s o r c u r .

    P r o

    t e c

    t i o n

    C o m p r e s s o r d i s c h a r g e t e m p p r o t e c t i o n

    O u t d o o r c o n d e n s e r h i t e m p p r o t e c t i o n

    C u r r e n t p r o t e c t i o n

    , N o

    . 1 f i x e d c o m p r e s s o r

    C u r r e n

    t p r o

    t e c t

    i o n

    , N o

    . 2 f i x e

    d c o m p r e s s o r

    3 - p

    h a s e p o w e r s u p p l y

    C o n n e c t

    i n d o o r

    C o n n e c t o u

    t d o o r

    M a i n c o n t r o l b o a r d

    M a i n u n i t A u x

    i l . u n

    i t 1

    A u x

    i l . u n

    i t 2

    A u x

    i l . u n

    i t 3

    S w

    1 c a p a c i

    t y s e

    t t i n g

    ( u n c

    h a n g e a

    b l e )

    A d d r e s s s e

    t t i n g

    C a p a c

    i t y s e

    t t i n g

    M o

    d e

    l o c k

    i n g

    O

    u t d o o r u n i t

    w i r i n g n a m a p l a t e

    L o a d p a t c h b o a r d

  • 7/27/2019 Inst Manual Outdoor252 450C

    9/12

    16(29) 1625 (46)35 (78)60 50

    380V 3N~

    50Hz80 70

    a

    b

    b

    a

    OUTDOOR UNIT INSTALLATION

    I n s nowy a rea s, f acilities s hould be insta lled top revent sn ow. (S ee the chart be low)(defectivef acilities m ay cau se malfunction.) Pleas e lift theb rac ket higher an d install s now shed at the airi nlet and a ir outlet.

    Snow sh ed for air inlet Snow shed for air outlet

    Sn ow sh ed for air inlet

    ELECTRIC WIRING

    CAUTION

    Please select power supply for indoor unit andoutdoor unit separately.

    The power supply should have speci ed branchcircuit with leakage protector and manual switch.

    Please pu t the conne ctive wiring system be tweenindoor unit and outdoor unit with refrigeran t pipingsystem tog ether.

    Pleas e comply with relevant Natio nal E lectric Stan dard.Power w iring sho uld be done by profess ional ele ctrician.

    The power s upply, lea kage protector and manual o f allthe indoor units connecting to the sam e outdoor unitshould be universal . (Pl eas e se t all the indoor unit powersupply of one sy stem into the sam e cir cuit.)

    It is su ggested to use 2 -core shielded wire as s ignalwire between indoor and outdoor units, mu lti-core wireis una vailab le.

    POWER WIRING

    Separate Power Supply (without power facility)(See table below)

    Model

    ItemPowersupply

    Min. Power wire diametermmWiring of mental and synthetic resin

    2 Manual switch(A) Leakage

    protectorGroundingwire CapacityFuse

    100mA0.1sec orless

    Size Size

    380V 3N~50Hz

    16(29)25 (46)

    35 (78)16

    Note: S elect po wer cord for these ve models separa telya ccording to rele vant sta ndard.

    Note: The wiring diameter and the l ength in the table indicatethe c ondition that the voltage dropping range is within

    2 %. If the length exceeds t he ab ove figure, please se lectthe wire diameter according to relevant standard.

    380V 3N~

    50Hz

    Outdoor unitpower supply

    Leakageprotector

    Manualswitch

    Lea kageprotectorManualsw itch

    Outdoor unit

    Outdoor unit

    Outdoor unit

    Outdoor unit

    Outdoor unit

    Outdoor unit

    GND

    GND

    GND

    GND

    GND

    GNDBranch box

    GND

    GND

    GND

    GND

    GND

    GND

    With power facilities Power facilities(with leakage protector)

    Branch box

    Lea kageprotectorManualsw itch

    Outdoor unit

    Outdoor unit

    Select the wire diameterPowe r wiring re fer to the m ain w ire (a ) con necting tobranch box and the wiring (b) be tween branch box a ndpower faci lities. Plea se se lect the wire diameter ac cordingto the following requirement.

    (1) Di amete r of main wire (a)Depends on the total horsepo wer of outdoor unit andfollowing ta ble.E.g In syste m:(5H p 1unit+8Hp 1unit+10Hp 1unit)Total H p=23H p ( Table ) siz e of w ire=70mm ( within50m)(2) W iring(b) between branch box a nd power equipmentDepends on the number of combined outdoor unit. If fewerthan 5, th e dia meter is t he s ame as t hat of ma in wire (a);if more than6, there will be 2 el ectric co ntrol boxes, a nd thediameter of wiring depends on the total horsepower of outdoor connecting to andfollowing table.

    units each elec tric control box

    2

    Select wire diameter ( ) (table) (unit :mm) 2

    Y DM H-25 2C 35 B Y DM H-28 0C 35 B

    Y DM H-33 5C 35 B Y DM H-40 0C 35 B

    YDMH-450C35B

    YDMH-252C35BYDMH-280C35BYDMH-335C35B

    YDMH-400C35B

    YDMH-450C35B

  • 7/27/2019 Inst Manual Outdoor252 450C

    10/12

    2.530m

    3.550m

    1.6mm30 15

    Single-phase220V~ 50Hz

    380V 3N~50Hz

    10~1415~1819~28

    29~3637~4748~50

    100100150

    200300300

    75100150

    200250300

  • 7/27/2019 Inst Manual Outdoor252 450C

    11/12

  • 7/27/2019 Inst Manual Outdoor252 450C

    12/12

    DE - COMMISSIONING DISMANTLING & DISPOSALThis product contains refrigerant under pressure, rotating parts, and electrical connections which

    may be a danger and cause injury! All work must only be carried out by competent persons using suitable protective clothing and safety precautions.

    1. Isolate all sources of electrical supply to theunit including any control system supplies switched by theunit. Ensure that all points of electrical and gasisolation are secured in the OFF position. The supply cables and gas pipework may then be disconnected and removed. For pointsof connection referto unit installation instructions.

    2. Remove all refrigerant from each system of the unit into a suitable container using a refrigerant reclaim or recovery unit. This refrigerant may then bere-used, if appropriate, or returned to the manufacturer for disposal. Under No circumstances should refrigerant be vented to atmosphere. Whereappropriate, drain the refrigerant oil from each system into a suitable container and dispose of according to local laws and regulations governingdisposal of oily wastes.

    3. Packaged unit can generally be removed in one piece after disconnection as above.Any fixing down bolts should be removed and then unit lifted fromposition using the points provided and equipment of adequate lifting capacity. Reference MUST be made to the unit installation instructions for unitweight and correct methods of lifting. Note that any residual or spilt refrigerant oil should be mopped up and disposed of as described above.

    4. After removal from position the unit parts may be disposed of according to local laws and regulations.

    dellortnoc y letomersitinUkcohscirtcelefoksiRlaunaMehtdaeRand may start without warning

    ENGLISH

    E-II-YDS-C-0907