®HYBRIDFLUSH AEF-801 SERIESAUTOMATIC/MANUAL FLUSH VALVE SYSTEM
FOR WATER CLOSETS (TOILETS) AND URINALS
Installation and Owner’s Manual
PUSH
Advanced Modern Technologies Corporation19800 Nordhoff Place, Chatsworth, CA 91311Tel: (818) 883-2682 Toll Free: (800) 874-7822 Fax: (818) 883-2620www.amtcorporation.com
REV. 09/17
A - Electronic Module with Top Metal Cover
B - Sensor Window with Latching Lock
C - Locking Ring (AMTC/Sloan or Zurn)
D - Top Screw Cover (Chrome Plastic)
E - Four (4) AA Alkaline Batteries
F - Ball Relief Valve (BRV)
G - Optional Push Button (PBCK)
®H - HYBRIDFLUSH Diaphragm
I - Allen Wrench
J - Screwdriver
K - Installation Wrench
Introduction
®Thank you for purchasing the HYBRIDFLUSH Model AEF-801 automatic/manual flush valvesystem by Advanced Modern Technologies Corporation (AMTC). The AEF-801 is designed to
® ® ®retrofit AMTC , Sloan and/or Zurn exposed type manual flushometers. The AEF-801 is interchangeable between urinals and water closets (toilet) and provides for a “true mechanical override” option through the use of the flush handle or push button. This patented “hybrid” design gives the user the ability to flush the fixture by infrared sensor activation or mechanically by using the flush handle or push button. The manual flush option will also allow the fixture to continue to function manually even if the battery power is drained or absent.
This manual will guide you through the proper installation and operation procedures to begin usingyour new AEF-801 automatic/manual flush valve system. Please read the installation instructionsthoroughly to assure proper installation and operation of the device.
Before you begin make sure that the following components are included:
2
PLEASE READ THE IMPORTANT NOTE BELOW BEFORE INSTALLING THE BATTERIES INTO THE UNIT!
IMPORTANT NOTE:It is highly recommended that you install the unit and tighten the locking ringbefore installing the batteries. Then check that there is no left over water inthe battery contact area as shown by the arrows in the diagram above. If thereis water present use a towel and wipe off all the water before installing thebatteries to avoid any possible damage to the batteries and the unit.
BATTERY CONTACT AREA
PLEASE DO THE FOLLOWING BEFORE INSTALLING THE BATTERIES1. MAKE SURE CONTACT AREA IS COMPLETELY DRY AFTER INSTALLING THE LOCKING RING AND BEFORE INSTALLING THE BATTERIES!2. DRY YOUR HANDS BEFORE HANDLING THE BATTERIES
BATTERIES
WARNING!PLEASE READ BEFORE INSTALLATION!
1. Read all instructions prior to installing this product.
2. Make sure that water volume of the unit (GPF) matches the water volume (GPF) on fixture.
3. Make sure you have the proper locking ring for your® ® ® fixture. Either for an AMTC /Sloan or Zurn valve body.
4. When installing unit on a poorly draining urinal or toilet bowl it is highly recommended that the angle stop on the flushometer be throttled back to the point where the water drains faster than the water being flushed to prevent overflow.
ATTENTION!Pre-Installation Note
3
All Installation Tools Included
STEP 1Using the Flathead Screwdriver turn theControl Stop Screw of the Flushometer to theright (clockwise) to completely shut of thewater. (Hold down the flush handle to relievepressure in the valve chamber).
Flushometer
Flathead Screwdriver
Control Stop Screw(shut off water)
STEP 2Using the Installation Wrench loosen and removethe Top Cover, Inside Cover, Relief Valve, andDiaphragm.
Diaphragm
Top Cover
Inside Cover
Relief Valve
STEP 31. Insert NEW Diaphragm and install Ball Relief Valve.
2. Place the Valve Module flat on top of the Diaphragm with the sensor eyes facing straight forward.
3. Place the Top Cover onto the Valve Module.
4. Insert the Locking Ring over the Top Cover and tighten with the Installation Wrench.
(1)
(2)
(3)
(4)Locking Ring
Top Metal Cover
Valve Module
Ball ReliefValve
Diaphragm
STEP 6Insert Sensor Windowinto place.
SensorWindow
STEP 7Lock the Battery Coverand Sensor Windowinto place using theAllen Wrench provided.Insert Latch Screw Cover.Turn water back on.
Latch Screw Cover
Allen Wrench
Lock
521 43 6
STEP 5Make any necessarySwitch Adjustments (Referto Switch Adjustment Guide stickerfound on the inside of the BatteryCover for instructions.)
STEP 4Remove Battery Cover, and installBatteries as shown. REMOVE ANYLEFT OVER WATER!!
Battery Cover
Batteries
The original Flush Handle may be kept and used as an alternative manual flush option. A Push Button Conversion Kit (PBCK) isincluded to convert the Flush Handle into a Push Button (Refer to Push Button Conversion Instructions on next page).
4
Installation Instructions
Switch Adjustments
To make switch adjustments please refer to the following diagram.A sticker with these directions can also be found on the inside ofthe Battery Cover for your convenience.
Directions:
1. Remove the Latch Screw Cover and slightly loosen the Latch Screw with the provided Allen Wrench.2. Remove Sensor Window and Rubber Cover.3. Make adjustments (refer to SWITCH ADJUSTMENT GUIDE).4. Re-install Sensor Window and Rubber Cover. Lock into place.
521 43 6
521 43 6
SENSOR DISTANCE
30”(75 CM)
26”(65 CM)
22”(55 CM)
18”(45 CM)
FLUSH MODE (URINAL ONLY)
NORMAL(EVERY TIME)
WATER SAVER(EVERY OTHER TIME)
GHOST FLUSH
OFF
ON(24 HOUR)
FLUSH VOLUME
TOILET MODE-LOW VOLUME
TOILET MODE-HIGH VOLUME
URINAL MODE-LOW VOLUME
URINAL MODE-HIGH VOLUME
FIXTURE MODE
TOILET
URINAL
�- SWITCHUP
DOWN
SWITCH ADJUSTMENT GUIDE
1
1
1
1
2
2
2
2
3
3
4
4
5
5
5
5
6
6
PUSH PUSH
Installation Wrench
Use to disassemble and converthandle into push button.
Use to removehandle assemblyfrom flushometer
1. Use the Installation Wrench to remove the handle assembly from the flushometer
2. Disassemble the handle assembly using the middle part of the Installation Wrench.
3. Remove handle and hard spring and replace with push button and soft spring.
4. Use the Installation Wrench to re-install new assembly.P
US
H
PU
SH
PBCK
Push Button Conversion Instructions
EE
( $
5
0 Degrees - 8 Degrees-
Sensor Angle Adjustment
Angle Adjustment Screw
OUTSIDE VIEW
INSIDE VIEW
Sensor Window
Latch
Latch Screw
1. Loosen the Latch using the provided Allen Wrench and remove the Sensor Window.2. Using a small Phillips Head Screwdriver slowly turn the Angle Adjustment Screw clockwise to increase the sensor angle downward or counter-clockwise to decrease the angle. (Sensor angle can be adjusted downward a maximum of 8 degrees).Important Note: When the sensor is angled, the sensor beam becomes longer.Therefore, the sensor range must be offset by applying a shorter sensor range usingthe switch adjustments. Make sure to set switches 1 & 2 up (18”) or 1 up & 2 down (22”)when angling the sensor for proper operation. 3. Re-install Sensor Window and lock the Latch into place with the provided Allen Wrench.
Directions:
Replacing Batteries
Directions:
To install batteries or make battery changes please refer to the followingdiagram.
1. Remove the Latch Screw Cover and slightly loosen the Latch Screw with the provided Allen Wrench.2. Turn the Latch forward and remove the Battery Cover by pulling it slightly up and out to the right.3. Install Four (4) AA Alkaline Batteries. Note: Make sure batteries are inserted correctly.4. Check to see that the red light comes on and then turns off inside the Sensor Window. Note: If the light does not come on, then the batteries might not be making proper contact.5. Re-install Battery Cover, lock into place with Allen Wrench, and insert Latch Screw Cover.
6
PUSH
®HYBRIDFLUSH Accessories (SOLD SEPARATELY)
Push Button Conversion Kit (PBCK)
PUSH
PUSH
The Push Button Complete Assembly (PB-C) includes all thenecessary parts of the push button that replaces the existing capto convert it into a mechanical push button. Normally, the PB-C isused when changing from an existing automatic flush valve thatrequires the handle area to be capped off.
® By using the push button with the HYBRIDFLUSH system the useris able to flush the urinal or toilet manually even when the batteries
® on the HYBRIDFLUSH system are drained. Installation of the pushbutton also solves the “handle kicking problem” usually associated with flushometer handles therefore reducing maintenance from leaky seals and extending the life of the flushometer.
The Push Button Conversion Kit (PBCK) includes a push button and spring that replaces the existing flush handle and spring to convert it into a mechanical push button.
® By using the push button with the HYBRIDFLUSH system the useris able to flush the urinal or toilet manually even when the batteries
® on the HYBRIDFLUSH system are drained. Installation of the pushbutton also solves the “handle kicking problem” usually associated with flushometer handles therefore reducing maintenance from leaky seals and extending the life of the flushometer.
Push Button Complete (PB-C)
Handle Cover (HC801)
The Handle Cover (HC801) is used to cap off handle area when the manual handle or the push button is not desired.
7
1
2
3
4
5
8
7
17
11
9
12
13
14
16
15-1
15-2
6
Refer toPage 10 forDiaphragm/Repair Kit Reference Chart
8
Parts Diagram
Parts List
9
REF PICTURE PART # DESCRIPTION REF PICTURE PART # DESCRIPTION
1 SC801 Screw for Top Plastic Cover DI-BRV-U05Ball Relief Valve Assembly for
HYBRIDFLUSH® - Urinal 0.5gpf
2 PC801 Plastic Cover for Housing DI-BRV-U10Ball Relief Valve Assembly for
HYBRIDFLUSH® - Urinal 1.0gpf
3 PH801 Plastic Housing Assembly DI-BRV-U15Ball Relief Valve Assembly for
HYBRIDFLUSH® - Urinal 1.5gpf
N/S EMA801 Electronic Module Assembly DI-BRV-U18
Ball Relief Valve Assembly for
HYBRIDFLUSH® - Urinal
0.125gpf or 1/8gpf
4 SC801 Screw for Plastic Housing DI-BRV-T11
Ball Relief Valve Assembly for
HYBRIDFLUSH® - Water Closet
1.1gpf
5 AABAT AA Cell Alkaline Battery (Each) DI-BRV-T12
Ball Relief Valve Assembly for
HYBRIDFLUSH® - Water Closet
1.28gpf
6 MBA801HYBRIDFLUSH® Motor & Base
AssemblyDI-BRV-T16
Ball Relief Valve Assembly for
HYBRIDFLUSH® - Water Closet
1.6gpf
7 EM801 Electronic Module DI-BRV-T35
Ball Relief Valve Assembly for
HYBRIDFLUSH® - Water Closet
3.5gpf
8 RC801 Rubber Cover for Electronic Module
9 BC801 Battery Cover (Metal)
11 CO801 Top Metal Cover
12 SWA801 Sensor Window Assembly
13 AW801Allen Wrench for Sensor Window
Screw
14 WSC801 Cover for Sensor Window Screw
15-1 LR801S-1 Locking Ring for Sloan Valve Body
15-2 LR801Z-1 Locking Ring for Zurn Valve Body
16 WR801 Installation Wrench
HYBRIDFLUSH® SENSOR OPERATED FLUSH VALVE SYSTEM PARTS Ball Relief Valves for HYBRIDFLUSH®
17
Diaphragm/Repair Kit Reference Chart
10
REF PICTURE PART # DESCRIPTION REF PICTURE PART # DESCRIPTION
DI-H-U05Diaphragm Assembly for
HYBRIDFLUSH® - Urinal 0.5gpfDI-SH-U05
Silicone Diaphragm Assembly
for HYBRIDFLUSH® - Urinal
0.5gpf
DI-H-U10Diaphragm Assembly for
HYBRIDFLUSH® - Urinal 1.0gpfDI-SH-U10
Silicone Diaphragm Assembly
for HYBRIDFLUSH® - Urinal
1.0gpf
DI-H-U15Diaphragm Assembly for
HYBRIDFLUSH® - Urinal 1.5gpfDI-SH-U15
Silicone Diaphragm Assembly
for HYBRIDFLUSH® - Urinal
1.5gpf
DI-H-U18
Diaphragm Assembly for
HYBRIDFLUSH® - Urinal
0.125gpf or 1/8gpf
DI-SH-U18
Silicone Diaphragm Assembly
for HYBRIDFLUSH® - Urinal
0.125gpf or 1/8gpf
DI-H-T11
Diaphragm Assembly for
HYBRIDFLUSH® - Water Closet
1.1gpf
DI-SH-T11
Silicone Diaphragm Assembly
for HYBRIDFLUSH® - Water
Closet 1.1gpf
DI-H-T12
Diaphragm Assembly for
HYBRIDFLUSH® - Water Closet
1.28gpf
DI-SH-T12
Silicone Diaphragm Assembly
for HYBRIDFLUSH® - Water
Closet 1.28gpf
DI-H-T16
Diaphragm Assembly for
HYBRIDFLUSH® - Water Closet
1.6gpf
DI-SH-T16
Silicone Diaphragm Assembly
for HYBRIDFLUSH® - Water
Closet 1.6gpf
DI-H-T35
Diaphragm Assembly for
HYBRIDFLUSH® - Water Closet
3.5gpf
DI-SH-T35
Silicone Diaphragm Assembly
for HYBRIDFLUSH® - Water
Closet 3.5gpf
REF PICTURE PART # DESCRIPTION REF PICTURE PART # DESCRIPTION
DI-RKH-U05Diaphragm Repair Kit for
HYBRIDFLUSH® - Urinal 0.5gpfDI-SRKH-U05
Silicone Diaphragm Repair Kit
for HYBRIDFLUSH® - Urinal
0.5gpf
DI-RKH-U10Diaphragm Repair Kit for
HYBRIDFLUSH® - Urinal 1.0gpfDI-SRKH-U10
Silicone Diaphragm Repair Kit
for HYBRIDFLUSH® - Urinal
1.0gpf
DI-RKH-U15Diaphragm Repair Kit for
HYBRIDFLUSH® - Urinal 1.5gpfDI-SRKH-U15
Silicone Diaphragm Repair Kit
for HYBRIDFLUSH® - Urinal
1.5gpf
DI-RKH-U18
Diaphragm Repair Kit for
HYBRIDFLUSH® - Urinal
0.125gpf or 1/8gpf
DI-SRKH-U18
Silicone Diaphragm Repair Kit
for HYBRIDFLUSH® - Urinal
0.125gpf or 1/8gpf
DI-RKH-T11
Diaphragm Repair Kit for
HYBRIDFLUSH® - Water Closet
1.1gpf
DI-SRKH-T11
Silicone Diaphragm Repair Kit
for HYBRIDFLUSH® - Water
Closet 1.1gpf
DI-RKH-T12
Diaphragm Repair Kit for
HYBRIDFLUSH® - Water Closet
1.28gpf
DI-SRKH-T12
Silicone Diaphragm Repair Kit
for HYBRIDFLUSH® - Water
Closet 1.28gpf
DI-RKH-T16
Diaphragm Repair Kit for
HYBRIDFLUSH® - Water Closet
1.6gpf
DI-SRKH-T16
Silicone Diaphragm Repair Kit
for HYBRIDFLUSH® - Water
Closet 1.6gpf
DI-RKH-T35
Diaphragm Repair Kit for
HYBRIDFLUSH® - Water Closet
3.5gpf
DI-SRKH-T35
Silicone Diaphragm Repair Kit
for HYBRIDFLUSH® - Water
Closet 3.5gpf
N/S
N/S N/S
Diaphragm Assemblies for HYBRIDFLUSH® Silicone Diaphragm Assemblies for HYBRIDFLUSH®
N/S
N/S
N/S
Diaphragm Repair Kits for HYBRIDFLUSH® Silicone Diaphragm Repair Kits for HYBRIDFLUSH®
N/S
N/S
PROBLEM SOLUTION
Check that all the battery contacts are correctly positioned.
Remove all the batteries and re-install them.
Drained battery indicator (batteries are dead) – replace/install new batteries.
Water got inside battery compartment. Clean battery contacts with metal brush
and replace all batteries.
Make sure that water is turned on.
Make sure to stand/sit within sensor range for at least 10 seconds or until red
light blinks once before you move away.
Make sure that batteries are properly installed and are making proper contact.
Make sure that sensor range is properly adjusted.
Remove and re-install the unit.
Replace the diaphragm (refer to diaphragm chart on page 10 of this manual).
Make sure you are within sensor range to activate the unit.
Watch red light blink once, then move away from sensor range.
Switch dip switch settings to lengthen sensor range.
Adjust sensor angle downward to read lower.
Check for dirt or debris on the diaphragm.
Remove and re-install the unit.
Check for dirt or debris on the diaphragm bleed hole.
Remove batteries and re-install.
Remove and re-install the unit.
Replace the diaphragm (refer to diaphragm chart on page 10 of this manual).
Valve is not picking up/reading user Sensor range is too short – Change dip switch settings to longer range.
Valve does not read user on high toilet
applications, or small children on urinals
Adjust sensor angle downward to allow sensor to pick up/read users at a lower
level.
Sensor will not activate if sensor angled
downwardMake sure dip switched 1 & 2 are both UP – Shortest sensor range.
Sensor range is too long – Change dip switch settings to shorter range.
Replace batteries if necessary.
Adjust the flush volume. Move dip switch 5 UP (high volume).
Use the control stop to increase the water volume.
Adjust the flush volume. Move dip switch 5 DOWN (low volume).
Replace the diaphragm (refer to diaphragm chart on page 10 of this manual).
Use the control stop to decrease the water volume.
Manual flush is too shortMake sure correct ball relief valve is being used (refer to chart on page 9 of this
manual).
Manual flush is too longMake sure correct ball relief valve is being used (refer to chart on page 9 of this
manual).
Threading on valve body may be damaged.
Check if valve body is AMTC/Sloan or Zurn. Use correct locking ring to match
valve body being used.
Locking ring may be damaged. Replace locking ring.
Electronic flush is too long
Red light does not come on in sensor window
after installation
Solid red light stays on in sensor window
Valve does not flush electronically
Valve flushes sometimes electronically
Locking ring does not fit valve body correctly
Valve does not shut off
Valve sensor is reading opposite wall (this
may cause batteries to drain more quickly)
Electronic flush is too short
Care and Maintenance
2- Do not directly spray unit with water or cleaner to avoid any possible malfunctions.
3- Maintain unit’s appearance by wiping the unit down using a soft damp clean cloth or towel to remove any residue
1- Do not use any abrasive or chemical cleaners to clean the unit as they may discolor or remove the chrome plating.
Troubleshooting
on the cover or the sensor window.
11
Warranty
AMTC WARRANTS ITS PRODUCTS TO BE FREE OF DEFECTS INMATERIAL AND WORKMANSHIP FOR A PERIOD OF FIVE (5) YEARSFROM DATE OF PURCHASE, WHEN PROPERLY INSTALLED AND UNDERNORMAL USE AND SERVICE. THESE PROVISIONS DO NOT INCLUDE THEBATTERIES SHIPPED WITH THE PRODUCTS. A DEFECTIVE PRODUCTMAY BE RETURNED TO AMTC OR ITS AUTHORIZED REPRESENTATIVESWITHIN FIVE (5) YEARS FROM DATE OF PURCHASE WITH THE PROPERINVOICE OF PURCHASE. AMTC, AT ITS DISCRETION, WILL REPLACE ORREPAIR DEFECTIVE PRODUCT AT NO CHARGE. CLAIMS FOR LABOR,TRANSPORTATION, AND ANY OTHER INCIDENTAL COSTS WILL NOT BEALLOWED. AMTC WILL NOT BE RESPONSIBLE FOR ANY CONSIDERABLEDAMAGES OF ANY KIND WHATSOEVER.
FOR TECHNICAL SUPPORT PLEASE CALL TOLL FREE 1-800-874-7822 ORVISIT OUR WEBSITE AT WWW.AMTCORPORATION.COM
MAKE SURE TO VISIT OUR WEBSITE PERIODICALLY FOR INFORMATIONON NEW PRODUCTS AND TO DOWNLOAD ANY IMPORTANT PRODUCTDOCUMENTS THAT YOU MAY NEED IN THE FUTURE.
Advanced Modern Technologies Corporation19800 Nordhoff Place, Chatsworth, CA 91311Tel: (818) 883-2682 Toll Free: (800) 874-7822 Fax: (818) 883-2620www.amtcorporation.com
REV. 09/17