installation instructions & manual book … · warning: to reduce the risk of injury to persons...

29
INSTALLATION INSTRUCTIONS & MANUAL BOOK FOR ARCHITECTS, GENERAL CONTRACTORS & DEALERS MODEL: MIRACLE•1 HIGH-QUALITY, MECHANICAL, LINEAR OPERATOR FOR SWING GATES ACCESS SYSTEMS INC © COPYRIGHT 1998 ELITE ACCESS SYSTEMS, INC. ® ® C Applied Applied REV-2 764

Upload: lecong

Post on 13-Sep-2018

213 views

Category:

Documents


0 download

TRANSCRIPT

INSTALLATION INSTRUCTIONS& MANUAL BOOK FOR ARCHITECTS,GENERAL CONTRACTORS & DEALERS

MODEL: MIRACLE•1HIGH-QUALITY, MECHANICAL,LINEAR OPERATOR FOR SWING GATES

ACCESS SYSTEMS INC

© COPYRIGHT 1998 ELITE ACCESS SYSTEMS, INC.

® ®CApplied Applied

REV-2

764

TABLE OF CONTENTS

2

ATTENTION: This handbook is exclusively for qualified installation personal, and assis-tance and/or maintenance service. - The performances indicated in this handbook are validonly if a correct assembly has been carried out.

© 1998 ELITE ACCESS SYSTEMS, INC.All rights reserved. No part of this Handbook may be reproduced by any means withoutthe expressed written permission of the publisher. Materials, components and specifi-cations are subject to change without notice. RELEASE 1

PLEASE DO NOT SERVICE!...UNLESS YOU ARE ANAUTHORIZED SERVICE TECHNICIAN! THANK YOU.

TABLE OF CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1WARNINGS AND PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2PROCEDURE FOR INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-7CONTROL BOARD BOX & HOW TO REMOVE CONTROL BOARD . . . . . . . . . . . . . . . . . . . . .8CONNECTING POWER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9CONNECTING POWER MASTER / SLAVE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10CHOOSING MOVEMENT DIRECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11CURRENT SENSOR ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11POWER SUPPLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12DRY CONTACT & RECEIVER WIRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13SAFETY AND CENTER LOOP INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14PHOTO CELL INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15CONTROL BOARD DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16CONTROL BOARD DESCRIPTION MASTER / SLAVE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17MAGLOCK & ALARM CONNECTORS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18BURGLAR ALARM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19GATE OPENING INSIDE INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20GATE OPENING OUTSIDE INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 EMERGENCY KEY RELEASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22CLOSE DELAY OPTION (MASTER / SLAVE ONLY) OPENING INSIDE . . . . . . . . . . . . . . . . .23CLOSE DELAY OPTION (MASTER / SLAVE ONLY) OPENING OUTSIDE . . . . . . . . . . . . . . .24TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25&26MIRACLE•1 PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27FEATURES AND SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .BACK COVER

WRONG

WRONGWRONG

WRONG

WRONG

WARNINGS AND PRECAUTIONS

3

If the timer is to be left in the “on”position, then add a safety loopand center loop.

Do not install upside down. Do notinstall on pickets, weld a reinforce-ment bar across several pickets.

Not for installation onany pedestrian gates. Not for installation on any pedestrian

passages or doorways.

WARNING: TO REDUCE THE RISK OF INJURY TO PERSONS THE MIRACLE•1 IS FOR VEHICULAR GATE USE ONLY

Be sure to read and follow all these important instructions before installation of the gate operator.Elite Access Systems, Inc. is not responsible for improper installations or failure to comply with localbuilding and electrical codes.

Do not install on uphill or downhill gates.

Do not install next tosprinklers or anyarea that may exposebottom to water.

Do not over-bend the wire connec-tion from the operator. To do so willcause the wires to eventually break.

IMPORTANT SAFETY INSTRUCTIONSWARNING - To reduce the risk of severe injury or death:1. READ AND FOLLOW ALL INSTRUCTIONS.2. Never let children operate or play with gate controls. Keep the remote control away from children.3. Always keep the moving gate in sight and away from people and objects until it is completely closed.

NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE.4. KEEP GATES PROPERLY MAINTAINED. Read the owner’s manual. Have a qualified service person

periodically inspect and make repairs to gate hardware.5. SAVE THESE INSTRUCTIONS.

MASONRYCOLUMN

HEAVY STEELPLATE

HEAVY STEELPLATE

HEAVYSTEELPLATE

STEELRE-BAR

TOP VIEWPOST

IMPORTANT:WELD RE-BAR BEHINDHINGES FOR MAXIMUM

STRENGTH

1/4" STEEL PLATE(REINFORCE IFNECESSARY)

10" MIN.

STEEL POST

IN

OUTPOST

GATE

PROCEDURE FOR INSTALLATIONOpen To The Inside

4

Indexing onCentral Hole

Indexing onMounting Hole

25.75”

7.75”

90°/105°

6”

10.5”

8.5”

6”

���������������������

MASONRYCOLUMN

STEEL POST

HEAVY STEEL PLATE

IMPORTANT:WELD RE-BAR BEHINDHINGES FOR MAXIMUM

STRENGTH

1/4" STEEL PLATE(REINFORCE IFNECESSARY)

HEAVY STEELPLATE

��

STEELRE-BAR

STEELRE-BAR

TOP VIEWPOST

IN

OUT

POSTGATE

25.75”

7.75”

8.5”

90°/105°6”

6”

PROCEDURE FOR INSTALLATIONOpen To The Outside

5

Indexingon Cen-tral Hole

Indexing onMounting Hole

Procedure For Installation (cont.)

6

STEP 1: REMOVE THE COVER - E - BY REMOVING4 SCREWS.

STEP 2: RELEASE THE MECHANICAL LOCK BYTURNING KEY - F - TO THE HORIZONTAL POSI-TION.

TACK WELD BRACKET AND

PLATE IN POSITION

TACK WELD BRACKET IN

POSITION

STEP 3: POSITION AND LEVEL THE OPERATOR,BRACKETS AND PLATE (SEE BELOW AND PAGE 3).TACK WELD PLATE AND BRACKETS IN POSITION.

F

8.5”

25.75”

With gate closed, position the plates on the gate taking care that the operator is kept level.IMPORTANT: Weld front bracket at the top of the bar so operator will not hit bar while traveling.

2.25”

Procedure For Installation (cont.)

7

CORRECT

CORRECT

WRONG

P L A C E M E N T O F M I R A C L E • 1 O N G AT EFor strength purposes, the front bracket must be welded in an area that can withstand heavyforces. Do not weld a cross bar on just a few pickets or the pickets will bend. Weld a cross baracross all of the pickets or weld the front bracket at the top of the gate directly to the frame.

������������ACCESS SYSTEMS INC

STEP 5: MAKE SURE THE OPERATOR IS LEVELOR THE OPERATOR WILL NOT FUNCTION PROP-ERLY. AN OFF-LEVEL INSTALLATION MAY CAUSETHE GATE OR OPERATOR TO FAIL PREMATURELY.

FULLY WELD BRACKET AND

PLATE

FULLY WELD BRACKET IN

POSITION

STEP 4: REMOVE OPERATOR AND FULLY WELDTHE PLATE AND BRACKETS TOP, BOTTOM ANDSIDES. CAUTION: WELDING WITH OPERATOR INPLACE MAY DAMAGE THE OPERATOR.

STEP 7: REMOVE NUT FROM BOLT ON FRONTOF OPERATOR. FIT THE GROUP - G - TO THEGATE. MANUALLY MOVE THE GATE OPEN ANDCLOSE. CHECK FOR SMOOTH AND UNOB-STRUCTED MOVEMENT. FULLY TIGHTEN THENUT.

STEP 6: REMOVE BOLT AND BUSHING FROMBACK OF OPERATOR. FIT THE OPERATOR TOTHE PIER USING THE HOLE WHICH IS THE MOSTSUITED TO THE OPENING DIMENSIONSREQUIRED.a.Place metal bushing into the bracket hole you will

be using.b.Fit operator bracket over hole with metal bushing.c.Use bolt and nut to secure operator to bracket.

c.

a.

b.

Procedure For Installation (cont.)

8

STEP 11: RE-INSTALL THE COVER.(REFER TO STEP 1)

STEP 10: ADJUST THE TRAVELINGDISTANCE WITH THE OUTSIDELIMIT SWITCH OF EACH SET.

STEP 9: CARRY OUT ALL APPRO-PRIATE CONNECTIONS IN THEFOLLOWING PAGES OF THE MAN-UAL TO POWER THE UNIT. THENGO TO STEP 10.

STEP8: LOCK THE OPERATOR BY TURNING KEY -F - TO THE VERTICAL POSITION WHILE PUSHINGOR PULLING ON THE GATE UNTIL YOU HEARTHE KEY RELEASE CLICK INTO PLACE.

F

OutsideSwitch

InsideSwitches

OutsideSwitch

TM

ACCESS SYSTEMS INC.

CONTROL BOARD BOX

9

HOW TO REMOVE CONTROL BOARD

Detach the J3 plug and the J1 plug. remove the three, long hex-shaped nutsand remove control board. Reverse this process to install the control board.

Unpack Control Board Box. Cut theplastic tie holding the transformerin the box.

Remove plastic tie andtransformer. Place rubberbumper (supplied) over tophole. This will keep waterfrom entering the ControlBoard Box.

J3J1

J1

J3

MIRACLE - 1rev 1.3

WHEN ONREPLACE FUSE

WA

RN

ING

: F

OR

C

ON

TIN

UE

D

PR

OT

EC

TIO

N

AG

AIN

ST

F

IRE

R

EP

LA

CE

O

NLY

WIT

H

SA

ME

T

YP

E

&

VO

LTA

GE

F

US

E

2A

250

V

1.5A

250

V

POWER

CHARGE OK

BAT LOW

CENTERLOOP

SAFETYLOOP

RADIO REC

STRIKEOPEN

CENTRAL CONTROL

60 0

TIMER

SYSTEMON

REVERSESENSOR

ALARMSENSOR

OPENINSIDE

OPENOUTSIDE

YESNOSTOP BYPOSITIVE

STOP

OFF ON

WA

RN

ING

: FO

R C

ON

TIN

UE

D

PR

OT

EC

TIO

N A

GA

INS

T F

IRE

R

EP

LA

CE

ON

LY W

ITH

SA

ME

T

YP

E &

VO

LTA

GE

FU

SE

8A

125

V

ACCESS SYSTEMS INC

®

MADE IN USA

MAGLOCK ALARM

WIRE GAUGE

16 AWG / 200 FT.

Battery

24 VDC

J1

GREEN

GREEN

BROW

N

BROW

NBLACK

BLAC

K

BLACK

BLACK

BLUE

BLUE

WHITE

WHITE

RED

RED

RED

RED

CONNECTING POWER

10

CAUTION: Do not over-bend the wire connectionfrom the operator.To do so will cause the wires toeventually break.

PROPER GROUNDING IS IMPORTANT

WRONG

IMPORTANT: Be sure to install the FlexConnector (supplied) to secure the wirein the Miracle-1 Control Board Box.

ACCESS SYSTEMS INC

®

MIRACLE - 1 M/SMADE IN USA

POWER

CHARGE OK

BATTERY LOW

SYSTEM ON

60 3

REVERSESENSOR

ALARMSENSOR

OPEN IN

CLOSE DLYOFF

OPEN OUT

ONPOS. STOP

CLOSE DLYON

OFFPOS. STOP

TIMER

WA

RN

ING

: F

OR

C

ON

TIN

UE

D

PR

OT

EC

TIO

N

AG

AIN

ST

F

IRE

R

EP

LA

CE

O

NLY

WIT

H

SA

ME

T

YP

E

&

VO

LTA

GE

F

US

E

WA

RN

ING

: FO

R C

ON

TIN

UE

D P

RO

TE

CT

ION

A

GA

INS

T F

IRE

RE

PL

AC

E O

NLY

WIT

H

SA

ME

TY

PE

& V

OLT

AG

E F

US

E

3A

15A

1.5A

250

V

OFF ON

MASTER SLAVE

REPLACE FUSEWHEN LED IS ON

CENTERLOOP

SAFETYLOOP

RADIO REC

STRIKEOPEN

MAGLOCK ALARM

CENTRAL CONTROL

R55

J2 J4

FS

O36

5

���������

Battery24 VDC

J1

GREEN

GREE

N

BROW

N

BROW

N

BLACK

BLAC

K

BLACK

BLACK

BLUE

BLUE

WHITE

WHITE

RED

RED

RED

GREEN

GREEN

BROW

N

BROWN

BLACK

BLACK

BLUE

BLUE

WHITE

WHITE

RED

RED

WIRE GAUGE

16 AWG / 200 FT.

MasterSlave

������

6 WIRES FROM OPERATOR #2 INSIDE CONDUITCONDUIT

FIELD WIRINGCOMPARTMENT

OPERATOR #1

OPERATOR #1

OPERATOR #2

OPERATOR #2

CONNECTING POWER Master / Slave

11

PROPER GROUNDING IS IMPORTANT

IMPORTANT: Be sure to install the FlexConnector (supplied) to secure the wiresin the Miracle-1 Control Board Box.

WRONG

CAUTION: Do not over-bend the wire connectionsfrom the operators. To do so will cause the wiresto eventually break.

60

OR

OPENINSIDE

OPENOUTSIDE

YESNO

OFF ON

60

OR

OPENINSIDE

OPENOUTSIDE

YESNO

OFF ON

CHOOSING MOVEMENT DIRECTIONSwitch the “Open Inside / Open Outside” switch on the control board to the

corresponding position for the proper direction.

OPEN INSIDE

OPEN OUTSIDE

Set the sensor adjustmentso when the gate hits anyobject while opening, it willstop and when the gate hitsany object while closing, itwill reverse. Note: If you acti-vate the operator and thegate stops in the middle ofthe driveway, the sensor isset too sensitive.

The sensors must be adjusted while thegate is in the opening or closing cycle.

CURRENT SENSOR ADJUSTMENT

12

OPTION - Stop by POS - STOPThis option is to be turned to yes if the gate willuse positive stops at the close position.IMPORTANT: It is necessary to still adjust yourlimit switch at the close position. The controllerwill look for the limit close first and then it willlook for the positive stop.

Sensor Adjustment

Stop by PositiveStop Option

Yellow Yellow

12

POWER SUPPLY

13

Use the plug-in transformer (sold by Elite Access System only) by hooking it up to 115Vand use Two Conductor, low voltage, 14 gauge / 300 watt direct burial, landscape light-ing cables (part #A W-100 or A W-500). Connect these wires to the two yellow wiresfrom operator connector(J3), to the plug-in transformer. Connect the battery cable to theharness connector from J1. The Timer LED will blink 3 times. After the blinks, check the“charge ok” LED, it must be on.

Maximum length of wire should notexceed 500 ft. If using more than 500feet, use 10AWG wire up to 1000 feet.

Polarity does not matter.

To 115v

ACCESS SYSTEMS INC

DRY CONTACT & RECEIVER WIRING

14

STRIKE OPEN12 & 7

Mount receiver insidethe control board box

as shown using velcro.Note that the receiver

is mounted upsidedown so the antenna

can fit through the holeat the bottom of thecontrol board box.

Black

White

Red

J316 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

������������

������������

������������

�������������

4'

4'

7'

4'

4'

4'

4'

4'

CenterLoop

SafetyLoop

SafetyLoop

TWISTED WIRES

FROM LOOP CUTS

7'

15'

������1/4"

1 1/2"

THREE WIRESLAYERED

LOOP CUT

TWIST WIRES

USE 14 AWG "uf" GRADE STRANDED WIRE

LOOP CUT

TO LOOPDETECTOR

YELLOW

BLUE YELLOW

LOOP DETEC.

BLUE

LOOP DETEC.

SAFETY & CENTER LOOP INSTALLATION

15

Center Loop

Safety Loop

J1

J3

MIRACLE - 1rev 1.3

WHEN ONREPLACE FUSE

WA

RN

ING

: F

OR

C

ON

TIN

UE

D

PR

OT

EC

TIO

N

AG

AIN

ST

F

IRE

R

EP

LA

CE

O

NLY

WIT

H

SA

ME

T

YP

E

&

VO

LTA

GE

F

US

E

2A

250

V

1.5A

250

V

POWER

CHARGE OK

BAT LOW

CENTERLOOP

SAFETYLOOP

RADIO REC

STRIKEOPEN

CENTRAL CONTROL

60 0

TIMER

SYSTEMON

REVERSESENSOR

ALARMSENSOR

OPENINSIDE

OPENOUTSIDE

YESNOSTOP BYPOSITIVE

STOP

OFF ON

WA

RN

ING

: FO

R C

ON

TIN

UE

D

PR

OT

EC

TIO

N A

GA

INS

T F

IRE

R

EP

LA

CE

ON

LY W

ITH

SA

ME

T

YP

E &

VO

LTA

GE

FU

SE

8A

125

V

ACCESS SYSTEMS INC

®

MADE IN USA

MAGLOCK ALARM

J1

GREEN

BROW

N

BLACK

BLACK

BLUE

WHITE

RED

RED

BLACK 16 AWG

BLACK 16 AWG

BLACK 22 AWG

BLACK

RED 22 AWG

1 2 3 4 5 6 24V to 240VDC(C1) (NO1)

LIGHT ON DARK ON

IMPORTANT!THIS SWITCH MUST BE IN THE

"LIGHT ON" POSITIONOR PHOTOCELL WILL NOT FUNCTION CORRECTLY.

P/N A OMRON

GROUND +24VDC

�����������

PHOTOCELLREFLECTOR

BRACKETWALL

LESS THAN 18"

GATE IS OPEN

J316 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

GREENBROW

N BLUE

WHITE

RED

PHOTOCELL INSTALLATION

16

TO REDUCE THE RISK OF INJURY, ELITE HIGHLY RECOMMENDS INSTALLING A PHOTOCELL SENSOR WHEN THE GATEOPENS TO LESS THAN 18” FROM A WALL OR ANY OTHER OBJECT. FOLLOW THE INSTALLATION INSTRUCTIONS PRO-VIDED WITH THE PHOTOCELL SENSOR FOR ACCURATE PLACEMENT OF THE PHOTOCELL AND THE REFLECTOR.

3

CONTROL BOARD DESCRIPTION

17

1. Open or Close Relay LED2. Control Relay LED3. Motor Fuse4. J1-Batteries and Motor Connector 5. Strike Open LED6. Safety Loop LED7. Radio Receiver LED8. Center Loop LED9. J3 Transformer & Input Commands Connector10. Central Control LED 11. Batteries Low LED 12. Charger Ok LED13. Power LED 14. Charging Power Fuse

15. Board Fuse16. Replace Charging Power Fuse LED17. Replace Board Power Fuse LED18. Timer Pot (3 to 60 sec.)19. Timer Active LED 20. Switch-Timer On / Off21. Stop by Positive Stop Option Switch22. Switch-Open Inside / Outside 23. Reverse Sensor Adjustment 24. Alarm Sensor LED25. System On LED26. Reverse Sensor LED27. Burglar & Alarm Sensor Output Connec-

tor

CONTROL BOARD DESCRIPTION Master / Slave

18

1. Open or Close Relay LED2. Control Relay LED3. Motor Fuse 4. J1-Batteries and Motor Connector 5. Strike Open LED6. Safety Loop LED7. Radio Receiver LED8. Center Loop LED9. J3 Transformer & Input Commands Connector10. Central Control LED 11. Charging Power Fuse 12. Board Fuse13. Replace Charging Power Fuse LED14. Replace Board Fuse LED

15. Batteries Low LED16. Charger Ok LED17. Power LED18. Timer Pot (3 to 60 sec.)19. Timer Working LED 20. Timer Switch On / Off21. Overlaping Gate On / Off22. Stop By Positive Stop Option Switch23. Switch Open Inside / Outside 24. Reverse Sensor Adjustment 25. Alarm Sensor LED26. System On LED27. Reverse Sensor LED28. Burglar & Alarm Sensor Output Connec-

tor

1 2 3 4

1 2 3

MAGLOCK

ALARM

orangeorange

whi

tew

hite

brow

nbr

own

MAGLOCK & ALARM CONNECTORS

Use the harness provided with theunit to make your connections to

these alarm outputs.

19

Burglar AlarmRelay Output1. Common2. N.C.

Alarm SensorRelay Output3. Common4. N.O.

Maglock1. Power-

Opening Inside2. Ground3. Power-

Opening Outside

Contact DataContact Rating 125 VAC - 0.5 A

J316 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 PROXIMITYSWITCH

BURGLAR ALARM

20

12VDCHOUSE

ALARM SYSTEMDRY CONTACT

N O

COM

1 2 3 4

ALARM

ALARM

white

white

whitewhite

ALARM / STROBE12VDC

N. O

.

CO

M

POWERFOR STROBE

1 2 3 4

N. O

.

CO

M

POWERFOR STROBE

1 2 3 4

brown

brown

ALARM

ALARM / STROBE12VDC

...HOUSE ALARM

ALARM SENSOR OUTPUT

The Alarm Sensor Output will close a cir-cuit as an indication of possible events:• Heavy Gate•• Traveling interrupted by an object

(Adjust the reverse sensor for sensitivity)

• This will disable the timer function andrelease mechanically the gate operation formanual movement until a new command isbeing issued.

USE LOWVOLTAGEWIRE 20 AWG

������������

������������

������

TWO WIRES (NO & COM) FROM PROXIMITY SWITCH

2"Max.

ACCESS SYSTEMS INC

IMPORTANT: When interfacing with ahouse alarm you must install positivestops at the gate closed position.

POWERFOR

MAGLOCK

N C

ora

ng

ew

hit

e

blu

eo

ran

ge

COM

2

3

1

MAGLOCK

21

Use thisposition for

Opening Inside

GATE OPENING INSIDE INSTALLATION OF...

21

MAGNETICLOCK

MAGNETICLOCKPLATE

CUSTOMBRACKET

GATE

FENCE

POWER FORSOLENOID

N O

COM

ora

ng

ew

hit

e

yellow

ora

ng

e

1

21

MAGLOCK

2

3

Use this position for

Opening Inside

SolenoidLock

...MAGNETIC LOCK

...SOLENOID LOCK

MA

GN

ET

IC L

OC

K

NOTE:The optional relay harness, allowing interface with an external devices, is available, only from Elite Access Systems

22

POWERFOR

MAGLOCK

N C

oran

geor

ange

wh

ite blu

e

COM

1

2 3

MAGLOCK

2 3

User thisposition for

OpeningOutside

GATE OPENING OUTSIDE INSTALLATION OF...

POWER FORSOLENOID

N O

COM

ora

ng

eo

ran

ge

wh

ite

yellow

1

2 3

MAGLOCK

2 3

Leave it empty

SolenoidLock

...MAGNETIC LOCK

...SOLENOID LOCK

MA

GN

ET

IC L

OC

K

NOTE:The optional relay harness, allowing interface with externaldevices, is available, only from Elite Access Systems

EMERGENCY KEY RELEASE

23

���������������

��������������

������������������

���������������

���������������

��������������

������������������

���������������

To move the gate during an emergencyor power failure, insert the key (step 1)into the key release hole on the front ofthe operator. Turn the key counter-clockwise to release the gate. Movethe gate manually (step 2) to the fullopen position.

Re-lock the operator (step 3) byturning the key release clockwisewhile pushing or pulling on the gateuntil you hear the key release clickinto place. The operator can nowresume normal operation as soonas power is restored (step 4).

STEP 2

STEP 3

STEP 4

90°

RE-LOCK������������������

���������������

UNLOCK

KEY (PROVIDED)

STEP 1

60 3

OPEN IN

CLOSE DLYOFF

OPEN OUT

ONPOS. STOP

CLOSE DLYON

OFFPOS. STOP

TIMER

OFF ON

ACCESS SYSTEMS INC

®

MIRACLE - 1 M/SMADE IN USA

POWER

CHARGE OK

BATTERY LOW

SYSTEM ON

60 3

REVERSESENSOR

ALARMSENSOR

OPEN IN

CLOSE DLYOFF

OPEN OUT

ONPOS. STOP

CLOSE DLYON

OFFPOS. STOP

TIMER

WA

RN

ING

: F

OR

C

ON

TIN

UE

D

PR

OT

EC

TIO

N

AG

AIN

ST

F

IRE

R

EP

LA

CE

O

NLY

WIT

H

SA

ME

T

YP

E

&

VO

LTA

GE

F

US

E

WA

RN

ING

: FO

R C

ON

TIN

UE

D P

RO

TE

CT

ION

A

GA

INS

T F

IRE

RE

PL

AC

E O

NLY

WIT

H

SA

ME

TY

PE

& V

OLT

AG

E F

US

E

3A

15A

1.5A

250

V

OFF ON

MASTER SLAVE

REPLACE FUSEWHEN LED IS ON

CENTERLOOP

SAFETYLOOP

RADIO REC

STRIKEOPEN

MAGLOCK ALARM

CENTRAL CONTROL

R55

J2 J4

FS

O36

5

SLAVE

MASTERMaster Delays to close

SLAVE

MASTERMaster Delays to close

inside property

inside property

24

CLOSE DELAY OPTION(Master / Slave only)This option is to be used when there is an

master/slave installation with overlaping gates.

OPENING INSIDE & OVERLAPPING TO THE OUTSIDE...

OPENING INSIDE & OVERLAPPING TO THE INSIDE...

25

60 3

OPEN IN

CLOSE DLYOFF

OPEN OUT

ONPOS. STOP

CLOSE DLYON

OFFPOS. STOP

TIMER

OFF ON

ACCESS SYSTEMS INC

®

MIRACLE - 1 M/SMADE IN USA

POWER

CHARGE OK

BATTERY LOW

SYSTEM ON

60 3

REVERSESENSOR

ALARMSENSOR

OPEN IN

CLOSE DLYOFF

OPEN OUT

ONPOS. STOP

CLOSE DLYON

OFFPOS. STOP

TIMER

WA

RN

ING

: F

OR

C

ON

TIN

UE

D

PR

OT

EC

TIO

N

AG

AIN

ST

F

IRE

R

EP

LA

CE

O

NLY

WIT

H

SA

ME

T

YP

E

&

VO

LTA

GE

F

US

E

WA

RN

ING

: FO

R C

ON

TIN

UE

D P

RO

TE

CT

ION

A

GA

INS

T F

IRE

RE

PL

AC

E O

NLY

WIT

H

SA

ME

TY

PE

& V

OLT

AG

E F

US

E

3A

15A

1.5A

250

V

OFF ON

MASTER SLAVE

REPLACE FUSEWHEN LED IS ON

CENTERLOOP

SAFETYLOOP

RADIO REC

STRIKEOPEN

MAGLOCK ALARM

CENTRAL CONTROL

R55

J2 J4

FS

O36

5

MASTER

SLAVE

Master Delays to close

MASTER

SLAVE

Master Delays to close

inside property

inside property

CLOSE DELAY OPTION(Master / Slave only)

This option is to be used when there is an master/slave installation with overlaping gates.

OPENING OUTSIDE & OVERLAPPING TO THE OUTSIDE...

OPENING OUTSIDE & OVERLAPPING TO THE INSIDE...

TROUBLESHOOTING

26

Check the fusesIf the gate is not moving in any direction be sure to check all of the LEDdisplays on the control board. If the board power or charging power LEDsare on, change the corresponding fuse on the right side of the board.

ACCESS SYSTEMS INC

®

MIRACLE - 1 M/SMADE IN USA

POWER

CHARGE OK

BATTERY LOW

SYSTEM ON

60 3

REVERSESENSOR

ALARMSENSOR

OPEN IN

CLOSE DLYOFF

OPEN OUT

ONPOS. STOP

CLOSE DLYON

OFFPOS. STOP

TIMER

WA

RN

ING

: F

OR

C

ON

TIN

UE

D

PR

OT

EC

TIO

N

AG

AIN

ST

F

IRE

R

EP

LA

CE

O

NLY

WIT

H

SA

ME

T

YP

E

&

VO

LTA

GE

F

US

E

WA

RN

ING

: FO

R C

ON

TIN

UE

D P

RO

TE

CT

ION

A

GA

INS

T F

IRE

RE

PL

AC

E O

NLY

WIT

H

SA

ME

TY

PE

& V

OLT

AG

E F

US

E

3A

15A

1.5A

250

V

OFF ON

MASTER SLAVE

REPLACE FUSEWHEN LED IS ON

CENTERLOOP

SAFETYLOOP

RADIO REC

STRIKEOPEN

MAGLOCK ALARM

CENTRAL CONTROL

R55

J2 J4

WA

RN

ING

: FO

R C

ON

TIN

UE

D P

RO

TE

CT

ION

A

GA

INS

T F

IRE

RE

PL

AC

E O

NLY

WIT

H

SA

ME

TY

PE

& V

OLT

AG

E F

US

E

15A

WA

RN

ING

: F

OR

C

ON

TIN

UE

D

PR

OT

EC

TIO

N

AG

AIN

ST

F

IRE

R

EP

LA

CE

O

NLY

WIT

H

SA

ME

T

YP

E

&

VO

LTA

GE

F

US

E

3A

1.5A

250

V

REPLACE FUSEWHEN LED IS ON

FS

O36

5

15 Amps

WA

RN

ING

: FO

R C

ON

TIN

UE

D P

RO

TE

CT

ION

A

GA

INS

T F

IRE

RE

PL

AC

E O

NLY

WIT

H

SA

ME

TY

PE

& V

OLT

AG

E F

US

E

8A

8 Amps

3 Amps 1.5 Amps

Change Fuse

WA

RN

ING

: F

OR

C

ON

TIN

UE

D

PR

OT

EC

TIO

N

AG

AIN

ST

F

IRE

R

EP

LA

CE

O

NLY

WIT

H

SA

ME

T

YP

E

&

VO

LTA

GE

F

US

E

3A

1.5A

250

V

REPLACE FUSEWHEN LED IS ON

2 Amps 1.5 Amps

Change Fuse

MASTER / SLAVE

SINGLE

Replace fuse onlywith specified rating*

(supplied by Elite Access)

TROUBLESHOOTING

27

You will see the alarm sensor LED on when

CENTERLOOP

SAFETYLOOP

RADIO REC

STRIKEOPEN

CENTRAL CONTROL

Checking Control Options (example - Radio Receiver)

Problem:The radio receiver LED is not on and thegate will not open with the radio receiver.

CENTERLOOP

SAFETYLOOP

RADIO REC

STRIKEOPEN

CENTRAL CONTROL

Problem:The radio receiver LED is on and thegate remains open.

Solution:The radio receiver has malfunc-tioned in the "ON" position

Solution:The radio receiver has malfunc-tioned in the "OFF" position.

2. The gate hits the driveway, curb or otherand gets stuck in an awkward position.

4. An object is on the gate framewhile the gate is moving.

1. The gate is too heavy or the arm is installed wrong.

3. The gate hinges are too tight or brokenand gate is not moving freely.

TM

ACCESS SYSTEMS INC.

24 VDC

Battery

Bolt

Bushing

Nut

Washer

Nut

MIRACLE•1 PARTS LIST

28

1 - Control Board Nuts (set)2 - Control Board3 - Backup Batteries4 - Operator5 - Control Board Box 6 - Cover

7 - Key Release8A - Front Mounting Plate,8B - Back Mounting Plate

9 - Motor Harness10 - Accessory Harness11 - Transformer

3

5

2

8B

6

4

1

108A 9

MAINTENANCE

This swing gate operator is designed to be very low in maintenance. For intensive duty instal-lations: (every six months) lubricate the operator fitting plates, lubricate the gate hinges, andcheck that electric connections are in good conditions. Any service must be performed by anauthorized service technician.

7

11

1

FEATURES AND SPECIFICATIONS

Overall Dimensions

4”

All specifications have been written and verified with our best attention. We do not take responsibility forpossible errors or omissions. We reserve the right to introduce changes to the technological progress.

MECHANICAL SPECIFICATIONS

MOTOR - 24V DC, 12 Amps.

CYCLES - 100 / Day.

SHIPPING WEIGHT:

Single Unit: 58 lbs. - Master/Slave: 89 lbs

TORQUE - 600 lbs. of torque.

FINISHING - Aluminum.

DIMENSIONS - L 39 1/2”, W 3 1/2”, H 4".

CAPABILITIES - Maximum gate size 15' wide, 600 lbs.

OPERATOR TRAVEL SPEED - 14 to 18 seconds 90° opening.

ELECTRICAL SPECIFICATIONS

RUNNING SYSTEM - Microcontroller with built-in watchdog system.

MODULAR BOARD - Uses LEDs to indicate all input and output functions of the gate operator.

SENSOR - When gate makes contact with an object while opening or closing, the gate will

reverse for 1 second, then go into neutral, so it can be pushed by hand.

TIMER - Can be set from 3 to 60 seconds.

MASTER/SLAVE - Dictates synchronized movement between two gate operators.

SAFETY LOOP INPUT - Anti-tailgating system uses a “stop only” method of operation. Will not

work as a commercial loop system.

ALARM OUTPUT - Can be interfaced with any home alarm system. Alarm will sound if the gate

is forced open manually. Optional siren speaker can be installed within the control box.

SPIKE SUPPRESSORS - Protected by spike suppressors.

ALTERNATE OUTPUTS - Master/slave, alarm system, and magnetic lock interface.

ELECTRONIC INPUTS - Any type of radio receiver, full-control system “push-open/stop/close”,

safety loop, photocell, telephone entry, and key switch.

ELECTRONICAL BOARD HOUSING DIMENSIONS - W 10 11⁄16" - H 13 1⁄4" - D 6 1⁄4"

HOUSING FINISH - Rain-proof steel box, gold plated and powder coated.

5 3/4”

39 1/2”

3 1/2”

29