installation manual: undertile heating mat€¦ · components not included as part of your warmup®...
TRANSCRIPT
TECHNICAL HELPLINE
0845 345 2288
IMPORTANTRead this manual before attempting to install your undertile heater.Incorrect installation could damage the heater and will invalidate your warranty.Complete and submit the warranty form online at www.warmup.co.uk.
by filling in your Guarantee information online at warmup.com
by filling in your Guarantee information online at
warmup.com
Installation Manual:
Undertile Heating Mat
The mat is available in 2 different wattages. Each mat is designed to pro-duce a specific amount of heat based on its length. For this reason you must never shorten the mat.
Specification for 150W Undertile Heating Mat Mat Size(m2) Nominal Watts Amps@230v1 150 0.651.5 225 0.982 300 1.303 450 1.964 600 2.615 750 3.266 900 3.917 1050 4.578 1200 5.229 1350 5.8710 1500 6.5211 1650 7.1715 2250 9.78
Specification for 200W Undertile Heating Mat Mat Size(m2) Nominal Watts [email protected] 100 0.4412000.871.5 300 1.302 400 1.743 600 2.614 800 3.485 1000 4.356 1200 5.227 1400 6.0981600 6.96918007.831020008.70
NOTE: The Warmup® XSTAT thermostat can switch up to 16 amps. If you are installing more than two heaters you may require a junction box. (see Page 4 - Electrical Considerations for details).
Specification for 150W Undertile Heating Mat Mat Size(m2) Ohms@230VAC1 352.71.5 235.12 176.33 117.64 88.175 70.536 58.787 50.388 44.089 39.1910 35.2711 32.0615 23.51
Specification for 200W Undertile Heating Mat Mat Size(m2) [email protected] 5231 264.51.5 176.32 132.33 88.24 66.15 52.96 44.17 37.88 33.19 29.410 26.5
If at any time your readings are not in line with the guidelines above, or you suspect there is a problem, please call the Warmup Technical Helpline at 0845 345 2288
Please complete the control card in the back of the manual and display at the consumer unit along with the installation instructions, heater location/layout plan and any wiring diagrams as per 17th Edition wiring regulations.
Nam
e
Address
Post code
Telephone num
ber
Installer name
Date of purchase
Batch No.
Serial N
o.
Please state which room
the heater(s) is installed:
I
hereby confirm
that I have read and understand the contents of the Installation M
anual, and that the heater has been installed as specified therein. I acknow
ledge that no claim can be brought against the m
anufacturer or its agents for any consequential loss or damage w
hatsoever. I confirm
that the heater was w
orking prior to the comm
encement of tiling.
otherKitchen
BathroomConservatory
Hall
Fill in your registration online at ww
w.w
armup.co.uk to choose your FREE GIFT.
Heater Location _________________________
Total Wattage __________________________
Place this card in a visible spot close to the consumer unit.
SignedDate Company stamp/name
CAUTIONRadiant Floor Heating SystemsWarming-Risk of electric shock
Electric-wiring and heating panels contained below the floor. Do not
penetrate with nails, screws, or similar devices. Do not restrict the thermal
emission of the heated floor.
Attention:
Do not cut or shorten the heating element.
Ensure that the entire heating elements including the joints are installed under the tiles in the installation.
The Heating element must be used in conjunction with a 30mA RCD.
Heater Model Resistance Before Resistance After Insulation Resistance
This form must be completed as part of the Warmup Guarantee. Ensure that the values are as per the instruction manual.
This card must be situated close to the consumer unit in a visible place.
Note: Draw a Plan showing the layout of the heater.
Warmup Plc 702 Tudor Estate Abbey Road London NW10 7UW T: 0845 345 2288 F: 0845 345 2299 www.warmup.co.uk
T0610The WARMUP word and associated logos are trade marks. © Warmup Plc. 2007 – Regd. TM Nos. 1257724, 4409934, 4409926, 5265707. E & OE.
702 Tudor EstateAbbey Road
LondonNW10 7UW
Web: www.warmup.co.uk
Email: [email protected]
Tel: 0845 345 2288
Fax: 0845 345 2299