IDC is highly focused on the energy efficiency and cost-effectiveness of its products when compared to traditional data centers.

We believe that as data demands grow and computing power increases, data center infrastructure will have to become more energy efficient otherwise rising energy costs will make even the smallest data center a losing economic proposition.

While the ?green data center? movement is beginning to take hold, it is only a matter of time before the need to change isn?t simply driven by a desire to protect the environment but also driven by the economic reality of rising energy costs

IDC's patented closed loop cooling system uses a pre-engineered airflow and cooling built- in that is optimized to efficiently deal with the current and future demands of the world?s most powerful computer

equipment

Closed loop cooling confines the hot and cold aisles within the enclosure

so that cooling is applied directly to the equipment. This allows companies to manage power consumption, cooling delivery and temperature set points at the rack level. This technology reduces cooling and electrical costs up to 50% vs. a traditional data center.

IDC? technology offers the lowest cost solution per kilowatt of compute capacity in the marketplace today -- as low as $5,000/ KW vs. $15,000 to $20,000/ KW for a traditional data center.

Our goal is to move the data center industry from being a huge consumer of electricity to being a small consumer of clean energy.

Since its inception, Instant Data Centers (IDC) has reinvented the data center industry using energy efficiency, cost effectiveness and high availability as guiding principles.

ABOUT OUR COMPANY

?I was able to deliver 5X the computer power with less then 10% of the physical cost and footprint that it would have been to support this infrastructure in an AOL data center.?

AOL DATA CENT ER PROJECTMIKE MANOS, CTO

Page 3: INSTANT DATA CENTERS · 2017-09-26 · Reduce costs to Plan, Build, and Implement OPEX SAVINGS Reduce footprint Reduce cooling and electrical costs Move by a pallet jack or forklift
Page 4: INSTANT DATA CENTERS · 2017-09-26 · Reduce costs to Plan, Build, and Implement OPEX SAVINGS Reduce footprint Reduce cooling and electrical costs Move by a pallet jack or forklift
Page 5: INSTANT DATA CENTERS · 2017-09-26 · Reduce costs to Plan, Build, and Implement OPEX SAVINGS Reduce footprint Reduce cooling and electrical costs Move by a pallet jack or forklift
Page 6: INSTANT DATA CENTERS · 2017-09-26 · Reduce costs to Plan, Build, and Implement OPEX SAVINGS Reduce footprint Reduce cooling and electrical costs Move by a pallet jack or forklift
Page 7: INSTANT DATA CENTERS · 2017-09-26 · Reduce costs to Plan, Build, and Implement OPEX SAVINGS Reduce footprint Reduce cooling and electrical costs Move by a pallet jack or forklift
Page 8: INSTANT DATA CENTERS · 2017-09-26 · Reduce costs to Plan, Build, and Implement OPEX SAVINGS Reduce footprint Reduce cooling and electrical costs Move by a pallet jack or forklift
Page 9: INSTANT DATA CENTERS · 2017-09-26 · Reduce costs to Plan, Build, and Implement OPEX SAVINGS Reduce footprint Reduce cooling and electrical costs Move by a pallet jack or forklift
Page 10: INSTANT DATA CENTERS · 2017-09-26 · Reduce costs to Plan, Build, and Implement OPEX SAVINGS Reduce footprint Reduce cooling and electrical costs Move by a pallet jack or forklift

Flip the switch on thinking about data centers.

Instant Data Centers has been doing Micro Data Centers (MDCs) for more than a decade. We have MDCs all over the globe serving all kinds of purposes. Disaster Recovery, Project Based and Primary Data Centers in an MDC are all possible.

We build our MDCs to withstand anything with redundancy throughout. You can put them just about anywhere which creates a new way of thinking in the data center community.

The possibilities begin to turn in your head "If I were able to move my equipment here... then I'd be able to do this instead..." Micro Data Centers open up so many possibilities.

We aren't traditional; we are new age, read this next part to get a view on how we think about it.

The Milk analogy.

Page 11: INSTANT DATA CENTERS · 2017-09-26 · Reduce costs to Plan, Build, and Implement OPEX SAVINGS Reduce footprint Reduce cooling and electrical costs Move by a pallet jack or forklift
Page 12: INSTANT DATA CENTERS · 2017-09-26 · Reduce costs to Plan, Build, and Implement OPEX SAVINGS Reduce footprint Reduce cooling and electrical costs Move by a pallet jack or forklift
Page 13: INSTANT DATA CENTERS · 2017-09-26 · Reduce costs to Plan, Build, and Implement OPEX SAVINGS Reduce footprint Reduce cooling and electrical costs Move by a pallet jack or forklift
Page 14: INSTANT DATA CENTERS · 2017-09-26 · Reduce costs to Plan, Build, and Implement OPEX SAVINGS Reduce footprint Reduce cooling and electrical costs Move by a pallet jack or forklift
Page 15: INSTANT DATA CENTERS · 2017-09-26 · Reduce costs to Plan, Build, and Implement OPEX SAVINGS Reduce footprint Reduce cooling and electrical costs Move by a pallet jack or forklift
Page 16: INSTANT DATA CENTERS · 2017-09-26 · Reduce costs to Plan, Build, and Implement OPEX SAVINGS Reduce footprint Reduce cooling and electrical costs Move by a pallet jack or forklift
Page 17: INSTANT DATA CENTERS · 2017-09-26 · Reduce costs to Plan, Build, and Implement OPEX SAVINGS Reduce footprint Reduce cooling and electrical costs Move by a pallet jack or forklift

FINDMEONTHEVIDEOONTHEWEBSITE

APPLICATIONSHybrid CloudData Center RetrofitConsolidationHigh-Density ZoneRemote LocationDisaster RecoveryEdge ComputeIoT & Smart Cities

CAPEX SAVINGSReduce costs to Plan, Build, and Implement

OPEX SAVINGSReduce footprintReduce cooling and electrical costs Move by a pallet jack or forklift Relocate your facility Reduce overall operating expenses

Instant Edge 44UMicro Data CenterUp to 12kW 42,000 BTU of closed loop cooling directly to the equipment. NEMA 12, 4 & 4x (IP55, 65&66). These enclosures can fully replace the data center building. Add single units or groups of units as requirements increase, providing a flexible, scalable and cost-effective IT solution.

The Instant Edge al lows you to add a full rack of IT equipment almost anywhere you need it. Included onboard is up to 12kW of closed loop AC cooling. By definition, closed loop means no particulates are getting into your cabinet. You can place these in caustic and dusty environments with no harm to your IT gear. Bring your IT equipment closer to your projects. This Micro Data Center allows you to expand the edge of your infrastructure and put your IT where it's useful.

Page 18: INSTANT DATA CENTERS · 2017-09-26 · Reduce costs to Plan, Build, and Implement OPEX SAVINGS Reduce footprint Reduce cooling and electrical costs Move by a pallet jack or forklift

FINDMEONTHEVIDEOONTHEWEBSITE

FEATURESBuilt-In Closed Loop Cooling Up To 12kW (42,000BTU) NEMA 12, 4, 4x, IP55 ,65 & 6619” EIA RackRapid DeploymentSound DampeningActive Fire Suppression Novec 123016R Insulation OptionElectronic Key(s) InterfaceCable Ingress Top or Bottom

Instant Data Centers, LLCMicro Data Center Solutions

[email protected]

(480) 462-0599510 S. 52nd Street STE 103

Tempe, AZ 85281

Instant Edge 44U NEMA4, 4X, IP65 & IP66DIMENSIONS 89” TALL 30 ½” WIDE 75” DEEP*

2260 MM TALL 762 MM WIDE 1905 MM DEEP*W/MISSION CRITICAL VENTING (MCV)

95” TALL 30 ½” WIDE 75” DEEP*2414 MM TALL 762 MM WIDE 1905 MM DEEP*

WEIGHT 1,100 LBS *DYNAMIC LOAD CAPACITY 1,500 LBS * OPERATIONAL TEMPERATURE - 40 TO 131 F*HIGH DENSITY EQUIPMENT CAPACITY 36ULOW DENSITY (NETWORK) EQUIPMENT CAPACITY 6UTOTAL RACK UNITS ”U” 42UTOTAL EQUIPMENT CAPACITY 12 KW/40,945 BTU (A/C)* DEPENDING UPON UPGRADE OPTIONS SELECTED

Mission Critical Venting (MCV) provides ventilation and redundant cooling at the cabinet-level. MCV is a patented product from Instant Data Centers available for almost any of our enclosures. MCV provides active fast triggered ventilation in the event of an AC equipment failure or total power loss. MCV will tr igger on temperature spike or can be programmed to ventilate on a timer for NiMH UPS gassing.

MCV includes NEMA4 IP66 sealed mechanical louvers on the front door and chimney. These louvers open, then high-powered fans turn on, and the enclosure ventilates to the atmosphere. Using ambient outside air, avoiding any heat buildup while a graceful shutdown is performed, or while the generator star ts up in the background.

Mission Critical Venting (MCV)

Page 19: INSTANT DATA CENTERS · 2017-09-26 · Reduce costs to Plan, Build, and Implement OPEX SAVINGS Reduce footprint Reduce cooling and electrical costs Move by a pallet jack or forklift

FINDMEONTHEVIDEOONTHEWEBSITE

APPLICATIONSHybrid CloudData Center RetrofitCommunication PoPMobile ComputingEmergency ManagementRemote Location Disaster RecoveryEdge ComputeIoT & Smart Cities

CAPEX SAVINGSReduce costs to plan, build, and implement

OPEX SAVINGSReduce footprintReduce cooling and electrical costs Relocate your facility Reduce overall operating expensesPerfectly Scalable

Micro Data Center built for the edge. The Mini Edge 30U, NEMA 12,4,&4x (IP55,65,66) Micro Data Center that provides from 2.5 kW up to 8.0 kW (8,000 – 27,000BTU) of closed loop cooling directly to the industry’s latest high-density equipment with no need for costly infrastructure. The mobile platform allows one person to move up to 1,000lbs of electronic equipment with ease. Rack & Stack where you want. Then ship it and plug it in.

The compact and affordable Mini Edge 30U provides the perfect platform for businesses and government agencies that require a quick and cost-effective turnkey data center solution or co-location alternative. The enclosure also is available in a ruggedized outdoor platform to deliver high-performance computing in remote and nonstandard locations throughout the world.

Mini Edge 30U

Page 20: INSTANT DATA CENTERS · 2017-09-26 · Reduce costs to Plan, Build, and Implement OPEX SAVINGS Reduce footprint Reduce cooling and electrical costs Move by a pallet jack or forklift

FINDMEONTHEVIDEOONTHEWEBSITE

FEATURESClosed Loop Cooling Welded FrameSupporting up to 6kW of ITNEMA 12,4,4x,IP55,65 & 6619” EIA RackRapid DeploymentSound DampeningActive Fire Suppression Novec 123016R Insulation OptionElectronic Key(s) Interface

Mini Edge 30U Instant Data Centers, LLCMicro Data Center Solutions

[email protected]

(480) 462-0599510 S. 52nd Street STE 103

Tempe, AZ 85281

Shock & Vibration Isolation (SVI)

NEMA 12,4,4X,IP55,IP65&IP66DIMENSIONS 50”TALL 30”WIDE 66”DEEP*

1397MMTALL 787MMWIDE 1676MMDEEP*WEIGHT 600LBS *DYNAMICLOADCAPACITY 1,000LBS *OPERATIONALTEMPERATURE 0TO120F*TOTALRACKUNITS“U” 24UTOTALEQUIPMENTCAPACITY 2.5KW/8,000BTU (A/C)

ADDITIONALCOOLINGOPTIONS UPTO 8.0KW/27,000BTU* DEPENDINGUPONUPGRADEOPTIONSSELECTED

Shock and vibration protection is part of every Instant Data Centers enclosure. This protects the sensitive equipment from shock and vibration damage while being moved as well as from vibrations commonly experienced in day to day operations. Servers are thousands of sensitive parts. Sparing them from vibration extends the useful lifespan of this expensive equipment.

SVI provides the ability to move the rack enclosure with the equipment in it. Perfect for companies in leased office space. When your lease is up and it’s time to move, take your data center with you.

FULLY CUSTOMIZED PATCH PANELS

RACK IS SUSPENDED WITHIN ENCLOSURE

Dropship equipment cabled and ready to operate. Transform complex digital infrastructure construction projects into a simplified shipping and receiving event. Forklift upgrade data centers, cellular sites, and IT closets. Streamline your integration and implementation.

Page 21: INSTANT DATA CENTERS · 2017-09-26 · Reduce costs to Plan, Build, and Implement OPEX SAVINGS Reduce footprint Reduce cooling and electrical costs Move by a pallet jack or forklift

FINDMEONTHEVIDEOONTHEWEBSITE

APPLICATIONSHybrid CloudHealth CareManufacturing IndustriesResearch & DevelopmentSmall BusinessesFilm & ProductionRemote LocationHospitality Leased SpaceEdge ComputeIoT & Smart Cities

CAPEX SAVINGSReduce costs to Plan, Build, and Implement

ADVANTAGESEasily MovedCompact, Fits AnywhereProtection from Dust, Water, TamperingReduce Noise LevelReduce overall operating expensesStackable

Edge Box 12U12U Rack Enclosure with Cooling.The Edge Box is a 12U, NEMA 12, 4, 4x (IP55,65&66) Micro Data Center that provides from 1.4 kW to 4.5 kW (4700BTU to 15,300BTU) of cooling directly to the equipment. The sturdy rack enclosure is completely sealed protecting valuable server equipment, routers, switches, and networking from dust, dirt, debris and tampering.

The compact Shield is suitable for clients needing IT in areas where equipment requires added levels of protection such as manufacturing facilities, military, research institutions, forensics and film & production industries.

Office space is popular for these enclosures. No longer do you need to build out a room specifically for a low quantity of high capacity servers. Everything you need is included and can be wheeled in with ease. No construction event, no tenant improvement and when you're done with that space, unplug it and move it.

Page 22: INSTANT DATA CENTERS · 2017-09-26 · Reduce costs to Plan, Build, and Implement OPEX SAVINGS Reduce footprint Reduce cooling and electrical costs Move by a pallet jack or forklift

FINDMEONTHEVIDEOONTHEWEBSITE

FEATURESBuilt-in Closed Loop Cooling 1.4kW To 4.5kW (4700BTU - 15,300BTU) NEMA 12, 4, 4x, IP55,65 & 6619” EIA Rack With Shock ProtectionRapid DeploymentSound Dampening <50 Dba @ 6’Active Fire Suppression Novec 1230Electronic Key(s) InterfaceFront & Rear Door AccessI/O Patch Panel Or Grommet Pass ThruSOX & HIPAA Compliant With

Tamperproof OptionsShip Fully Equipped

Edge Box 12U

Instant Data Centers, LLCMicro Data Center Solutions

[email protected]

(480) 462-0599510 S. 52nd Street STE 103

Tempe, AZ 85281

SPECIFICATIONSNEMA 12,4, 4X, IP55, IP65 & IP66DIMENSIONS 30” TALL 25/35/45” WIDE** 36” DEEP*

762 MM TALL 635/889/1143 MM WIDE 762 MM DEEP*WEIGHT 275LBS / 125KG*DYNAMIC LOAD CAPACITY 300LBS / 136KG* OPERATIONAL TEMPERATURE - 4 TO 167 F*TOTAL RACK UNITS ”U” 12UTOTAL EQUIPMENT CAPACITY 1.4-4.5KW / 4776-15,353 BTU* DEPENDING UPON UPGRADE OPTIONS SELECTED** DEPENDING UPON MOUNTING OF AC OR HEAT EXCHANGER

HEALTHCARE The enclosures are physically secure, with the combination of our access control keys this provides the audit record keeping requirement for SOX and HIPAA at the cabinet level. These enclosures provide the cooling needed for the Servers used to compute complex IT operations need in today's IT focused healthcare.

STACKABLEEach unit is manufactured with the ability to stack onto one another. With recessed patterns designed to fit the casters, they lock into place with an additional collar to allow heat to pass through. Ports are available to digitally connect the two boxes as well. It becomes a building block operation at this point. Share resources between systems and scale or down as you need them.

REMOTE OFFICEThese cabinets can be racked and stacked at a location of your choice. Configured, then unplugged and shipped to any location. The cooling equipment, along with environmentals, door monitoring sensors , and all other DCIM can be monitored remotely. Cut your travel time down to a shipping and receiving event. No longer need to travel to set up remote location IT.

Page 23: INSTANT DATA CENTERS · 2017-09-26 · Reduce costs to Plan, Build, and Implement OPEX SAVINGS Reduce footprint Reduce cooling and electrical costs Move by a pallet jack or forklift

Raser HPCThe Raser HPC is a 42U, high-density, hyper-efficient Micro-Modular Data Center™ capable of providing redundant cooling for IT heat loads from 20 to 80 kW.

The enclosure uses pre-engineered closed loop (re-circulated) cooling with zero bypass airflow. This “best practice” method of cooling contains the hot and cold aisles providing one of the greenest IT solutions on the market today with a PUE as low as 1.1.

APPLICATIONS

Data Center ImplementationUsing Chilled or HighTemperature Water

High PerformanceComputing

Easy Cloud Implementation

Grid Computing

High-Density Zone

Data Center Hot Zones

SAVINGS

CapEx

Reduce the costs to plan,build, and implement yournew facility by up to 80% vs.a Traditional Data Center(TDC)

OpEx

Reduce footprint up to 75%vs. TDC

Reduce cooling andelectrical costs up to 50%

Product can be moved by apallet jack or forklift -reduce costs to relocateyour facility by up to 50%

Reduce overall operatingcosts up to 65%

Time

Enclosures can be deliveredwithin 8 weeks compared to2 years for a TDC

Streamline supply chainship-tested, cabled andready

Deployable outdoors or indoors, the R.A.S.E.R. HD features active firesuppression, electronic security and environmental monitoring. Theseinterfaces make it the most powerful and easy to implementcontainerized data center product on the market today.

Grouped together or as single units, more than 1000 W/ft2 density can be achieved with little or no site prep, design or construction.

*Blade servers sold separately.

®

Page 24: INSTANT DATA CENTERS · 2017-09-26 · Reduce costs to Plan, Build, and Implement OPEX SAVINGS Reduce footprint Reduce cooling and electrical costs Move by a pallet jack or forklift

Product Features

Built-in closed loop coolingcan support high temperaturewater and IT loads from 20 to80 kW

Fully redundant coolingsystem configuration withself-adjusting valves, requiresonly a mechanical hookup

Accepts low and hightemperature cooling water

Hot swappable and fieldupgradable Heat eXchanger(HX) units can supportmultiple configurations

Hot swappable and alarmedfan assemblies assurecontinuous operations

Indoor/ Outdoor NEMA 4enclosure provides superiorstrength and protectsequipment from the elements

Shock and vibration isolation

Industry standard 19” wide x42” deep racks are fullyadjustable

Built-in environmentalmonitoring with optional IPcontrol and GUI interface

Options

EMI Shielding

Stand alone programmableencrypted security systemwith audit trail

16R insulation/fire protection

Fire protection using Novec1230

Smart power distribution unitswith outlet switching andpower monitoring

Raser HPC

Technical Specifications: Dimensions.......................................................95” tall x 47” wide x 64” long Weight………………………………………………………….....2000-2300 lbs* Dynamic Load Capacity……………………………………….……….2000 lbs Operational Temperature……………………………………...…-40 to 130˚ F* High Density Equipment Capacity…………...………….….……...……...42U Total Equipment Capacity…………………………………………20 to 80 kW* Heat Exchangers Available………………………………...……Single 20 kW

…………………………………...…Single 40 kW …………………………… …...……..Dual 20 kW ………………………………….…….Dual 40 kW

Water Connections Per Heat Exchanger………………….…..Inlet 1½” NPT …….……………...Outlet 1½” NPT …...………....Condensate ½” NPT

Heat Exchanger Water Flow Per Unit……………………..20 kW-12.5 GPM …………….……...….40 kW-19 GPM

Internal Air Flow Per Heat Exchange……………………..20 kW-1750 CFM ...............................40 kW-2350 CFM

Water supply temperature………………………………………….43 to 90˚ F All Capacity Ratings Based on 43˚ F Water Supply * depending upon upgrade options selected

A/C Power Options: Standard – 208-230 VAC 50/60 Hz 20 kW-700 WATTS 40 kW-1200 WATTS Optional – 48 VDC 20 kW-624 WATTS 40 kW-1152 WATTS