De-bubble Laminator
User’s Book
1.Safety Regulations
For your safety, please read this handbook carefully to be more
familiar with the application and limitations of the machines and the
related potential risks.
1.1 Read the instructions before using the equipment
1.2 Do not boot the equipment before closing the bin gate
1.3 The operation air pressure for this equipment ranges from 0.2 to
0.6 MPa. Any air pressure falling beyond this range will damage the
machine
1.4 This machine adopts the third grounding method. It is important
to keep the grounding normal. Poor grounding will cause the
dangers towards the machine and user
1.5 Electricity Box should not be opened without professional staffs
are present
2.Parameters
Power: AC220V 1500W
Selective:AC110V、AC220V
Operation Air Pressure:0—0.2Mpa
Work Environment: 20-30℃, clean and dust-free
Laminating: Flat Type Lamination
Production Efficiency: 2~4min/1pcs
Heating Method: Constant temperature
Applicable Size: Below 7"
Size of Equipment: 320*310*420mm
Height of Equipment: About 32kg
3.Features
*No Modules Needed, No Debubbling Process Needed;
*Press to Boot, Easy Operation
*Smart Constant Pressure; Automatic Shift to the Lamination and
Debubbling Mode
4.Inspection and Alignment
1.Check that whether the tray is smooth 2.Check that whether there are
some foreign matters on the
silicone pad
3.Module Alignment 4. Alignment on the silicone (LCD
screen is on the silicone while IC
is beyond the silicone)
5.Put into the laminator 6. If the scree is with long flat cable,
put the product on the external
part of the anvil cell and close the
door
5.Operation Process
Screen-Pressing Process
5.1 Check that whether the power and air source is normal or not and
whether the vacuum pump power and pipe are connected to the
equipment;
5.2 Switch on the power and press the button to boot the equipment
to check that whether the equipment can operate normally or not;
5.3Put the LCD with the OCA glue on the cut silicone (please stagger
the silicone away from the IC position of the flat cable);
5.4 Open the gate and put the tray on the cabinet;
5.5 Close the cabinet gate;
5.6 Press button to boot the equipment;
5.7 Wait patiently for 2 to 6 minutes;
5.8 Wait until the two indicator lights off or the vacuum table turns to
the minimal value. Open the cabinet gate and take out the product;
5.9 The process completed, check whether the product is normal or
not.
6.Debubbling Process
Note: when coating the OCA glue, the bubbles may be too large in
some cases, which results in the bubbles existing after lamination.
Please follow the following methods to debubble.
6.1 Please place the laminated assembly on the foam (please make
sure that the foam stagger from the IC of flat cable, as illustrated)
6.2 Open the gate and place the tray with products on the cabinet
6.3 Close the gate
6.4 Press the Button to put down the equipment
6.5 Predict the duration based on the exact situation
6.6Again press to put down the machine
Maintenance
Projects Items
Formwork Check that whether there are
some foreign matters. If positive,
please clean them
Lamination Guide Pillar and Work
Platform Sideway
Add some lubricating oil to the
guide pillar and sideway regularly
to make sure the movement is
smooth
Vacuum Pump Change the oil every three
months if necessary
Relation between Vacuum Degree and Altitude
Generally, the design and tested parameters of the vacuum pump
are conducted under the standardized air pressure environment. If the
altitude is changing, the exact performance will also change.
The exact parameters are displayed in Table 1:
Altitude
(m)
Vacuum Degree
(-Mpa) (mmHg)
0 0.1013 760
200 0.0990 742.7
400 0.0968 726.2
500 0.0957 717.9
1000 0.0902 676.7
1500 0.0846 634.7
2000 0.0790 593.3
Examples: Chengdu of Sichuan Altitude 505.9 Vacuum Degree ranges
from 93 to 95, normal
Yulin of Shanxi Altitude 1057.5 Vacuum Degree ranges from
80 to 90, normal
Debugging of Vacuum Pressure Gage
1、Debugging of SMC Vacuum Pressure Gage
<Process>
1.1 Enter the Pressure Setting Status
(1) As Stated Above
(2) Set the pressure switch to automatically
enter the debugging mode after the
power is switched on
Press one time under the debugging
mode to enter the pressure setting status
1.2 Under the pressure setting status, [P_1] and the Set Value will be displayed
alternatively on the screen
Note: [P_1] will be shown in the delayed-type constantly-open output mode.
[m_1] will appear in the delayed-type constantly-closed output mode. (P1L,P1H)
will appear in the comparative-type constantly-open output mode. (n1L,n1H.)
will appear in the comparative-type constantly-closed output mode.
<How to configure the value>
Examples:
1.2.1 Use “Up” and “Down” to change the
set value. The first figure will flash
1.2.2 Use “up” and “down” to configure any
button
1.3 Every time pressing the “SET”, the next figure (higher digit) will flash. When the
highest digit is zero, or will flash.
If the highest digit flashes, press “set”, the lowest digit will flash.
1.4Hold the “SET” for over one second, return to the set value display mode
2、Panasonic Vacuum Pressure Gage Debugging
Only need to press the “up” and “down” to
adjust the reference value shown in Table 1
”Present Value” displayed in Main
“Reference Value” displayed in Sub
0 action is needed (no need for operation) to display the present and
reference values.
3、Operation Method, Menu Setting Mode
Under the RUN mode, hold the MODE button for 2 seconds to switch to
the Menu setting mode
RUN Model
Hold them for 2 seconds
Comparative Output 1
Output setting
Comparative 2 Output
setting
NO/NC Switch
Response Time Setting
Main Screen Display Switch
Unit Switch
During the setting, hold the Mode
button to switch to RUN mode
Save the changed items
EASY Mode/Window sode/Assignment
Acceptance Mode.
High-Performance Mode, with
automatic reference input/ forced zero
input/ emulated output.
Set the Output 1/2 as NO/NC
2.5/5/10/25/50/100/250/500/1,000/5,0
00ms
Prolong the Response Time to avoid
the junction vibration misoperation .
When the output On is red/ green/
constantly red/ constantly green.
4、Return to Zero
The pressure hole will forcefully
return the pressure to zero in the
atmospheric conditions Long press