instruction manual sensorika weighng indicator 43000 series
TRANSCRIPT
WEIGHING INDICATOR
ABS Enclosure IP 65 & IP67 Environmental Protection
43050 & 43050-W
OPERATION MANUAL
OPERATIONMANUAL SENSORIKA43050(W)
2
FCCNOTE: THISEQUIPMENTHASBEENTESTEDANDFOUNDTOCOMPLYWITHTHELIMITSFORACLASSADIGITALDEVICE,PURSUANTTOPART15OFTHEFCCRULES.THESELIMITSAREDESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST HARMFUL INTERFERENCEWHENTHEEQUIPMENTISOPERATEDINACOMMERCIALENVIRONMENT.THISEQUIPMENTGENERATES,USES, AND CAN RADIATE RADIO FREQUENCY ENERGY AND, IF NOT INSTALLED AND USED INACCORDANCE WITH THE INSTRUCTION MANUAL, MAY CAUSE HARMFUL INTERFERENCE TORADIOCOMMUNICATIONS.OPERATIONOFTHISEQUIPMENTINARESIDENTIALAREAISLIKELYTOCAUSEHARMFULINTERFERENCEINWHICHCASETHEUSERWILLBEREQUIREDTOCORRECTTHEINTERFERENCEATHISOWNEXPENSE.
INDUSTRYCANADANOTE:
THISCLASSADIGITALAPPARATUSCOMPLIESWITHTHECANADIANICES‐003.
CETAPPAREILNUMÉRIQUEDELACLASSEAESTCONFORMEÀLANORMENMB‐003DUCANADA.
OPERATIONMANUAL SENSORIKA43050(W)
3
TableofContents
1. INTRODUCTION 41.1 TECHNICALFEATURES 4
2. KNOWYOURINDICATOR 42.1 EXTERNALVIEWANDDIMENTIONS 42.2 OVERVIEWOFDISPLAYINDICATYORS 52.3 OVERVIEWOFINDICATOR’SCONTROLBUTTONS 5
3. INSTALLATION 63.1 UNPACKINGANDCHECKING 63.2 SELECTINGTHELOCATION 63.3 CONNECTINGINDICATORTOASCALEBASE 63.4 CONNECTINGPORTRS232 73.5 AC&DCPOWER 7
4. OPERATINGTHEINDICATOR 84.1 CALIBRATIONMENUTREE 84.2 SETUPMENUTREE 94.3 MENUDESCRIPTION 94.3.1 CALIBRATIONMENU 94.3.2 CALIBRATIONMENUTORRATI NG THE I NDI C� 114.3.3 SETUPMENU(CUSTOMERSETTINGS) 124.3.3.1 CHECKWEIGHINGFUCTIONSETUP 124.3.3.2 PIECECOUNTINGFUNCTIONSETUP 134.3.3.3 DIGITALTAREFUNCTIONSETUP 134.3.3.4 HOLDFUNCTIONSETUP 144.3.3.5 AUTOTAREFUNCTIONSETUP 144.3.3.6 FILTERFUNCTION 144.3.3.7 ANIMALWEIGHINGFUNCTION 144.3.3.8 BACKLIGHTFUNCTION 144.3.3.9 SOUND(BEEP)FUNCTION 144.3.3.10 AUTOPOWEROFFFUNCTION 154.3.3.11 COMUNICATIONWITHPRINTERORPC 154.3.3.12 SETUPPRINTINGFORMAT 154.3.3.13 A/DCONVERTORTEST 174.3.3.14 WEIGHINGUNITSENABLING/DISABLING 174.3.3.15 TIMEANDDATESETTING 174.3.4 ADDITIONALKEYFUNCTIONS 174.3.4.1 WEIGHTACCUMULATION 174.3.4.2 LOCKKEYBOARD 18
5. LIMITEDWARANTY 18
6. SHIPPINGINFORMATION 18
OPERATIONMANUAL SENSORIKA43050(W)
4
1. INTRODUCTION
ThankyouforchoosingSensorika43000Seriesweighingindicator.ThemodelsSensorika43050and43050‐Warerugged,reliableelectronicweighingindicatorsinanIP65(dustproof)andIP67washdownenclosuredesignedforeasyoperationinindustrialapplications.
The43000Seriescandriveupto12(twelve)350Ohmloadcells.TheIndicatorhasanenhanceddigitalfilterwhichallowsstabledisplayreadingevenifyousetthedisplayresolutionto1:100,000.
TheLCDdisplayhasbluebacklightand6digits,1”/2.5cminheight.Itprovideseasyreadingofdisplayfromadistanceorevenwithpoorlightingontheweighingstation.
Anadjustablemountingbracketallowstheindicatortobeinstalledonatable,wallorscalescolumn.
1.1 TECHNICALFEATURES
Capacity(lborkg) 1to999999DisplayResolution Max.100,000.Recommended:nomorethan30,000Weighingunits kg,g,lb,lb/oz
FunctionsPartcounting,Animalweighing,Accumulatingweight,Checkweigher,Doublerangescale,Digitaltare,etc.
Stabilizationtime ≤2secondsAutozerotrackingcapturerange 0~5.0divisionsZerorange 0~99%Spancalibration SelectablecalibrationweightWeighingsystem AnalogstraingaugeloadcellLoadcellexcitationvoltage 12VDCLoadcellinputsensitivity ≥2.0mV/VLoadcelldrive 1x1000Ohmorupto12x350OhmloadcellsDisplay 6DigitsLCDwithbluebacklight,digitsize1”/25mmPower Poweradapter100~240VAC50/60Hz/9VDC800mA
BatterylifeUpto60hrsofconstantusewith4loadcellandbacklightoff,
about30hrswithbacklightonOperatingtemperature 0°C~40°C(32°F~113°F)Keyboard 6mainboardbuttonsand5navigationkeysEnclosure ABSIP65orIP67
2. KNOWYOURINDICATOR
2.1 EXTERNALVIEWANDDIMENTIONS
OPERATIONMANUAL SENSORIKA43050(W)
5
Fig.1
2.2 OVERVIEWOFDISPLAYINDICATYORS
Fig.2
1 Stabilityindicator2 Netweightindicator3 “Minus”indicationofnegativeweight4 Indicatoroftare.ShowsthatTarevalueisstoredinRAM5 StableZeroindicator6 Externalpowerconnected7 Batteryloadindicator8 Weighingunitindicator9 Weighingunitindicator10 Partcountingindicator11 Weighingunitindicator12 Checkweighingindicator13 Dualplatformmodeindicator
2.3 OVERVIEWOFINDICATOR’SCONTROLBUTTONS
On/off button.
Unit selection button. It is used to select units (lb, oz, kg), piece-counting mode and as the Escape button in the Calibration or Setup menus.
Note: You can only select a unit that is enabled. To enable/disable units, go to parameter [Units] in the Customer Setup menu.
PLU button. Used to enter Setup or Calibration menus.
OPERATIONMANUAL SENSORIKA43050(W)
6
Gross/Net button. Press shortly to see Gross or Net weights. Press and hold to enter the Checkweighing mode.
Zero button. It sets the weight to zero. Press and hold the button to enter the Display Test mode.
Tare button. Press to accept recipient weight placed on the scale as tare. Press and hold to access the stored tare values.
MR and (LEFT) navigation key. Press to show accumulated total weight. In the menu mode, it is used to return to the previous step or escape from any parameter.
M+ and (RIGHT) navigation key. In the weight accumulation mode, press it to store and add the displayed weight to the value in memory.
1-2 and (UP) navigation key. Press to change from the scale plate to an external plate (only for double platform function scales). In the menu mode, it increases the value (number) on the display.
MC and (DOWN) navigation key. Press it to erase the accumulated weight from memory. In the menu mode, it decreases the value (number) on the display.
(ENTER) navigation key. Press to confirm the selection made in the programming mode. Press and hold to lock or unlock the keyboard.
3. INSTALLATION
3.1 UNPACKINGANDCHECKING
Openthepackageandremovetheinstrumentandtheaccessories.Checkthecompletenessofthedelivery.
Checktheinstrumentforanytransportdamages.Immediatelyinformyourdealerifyouhaveanycomplaintorseeanypartmissing.Yourindicatorpackageshouldcontain:
• IndicatorSensorika43050or43050‐W• Stainlesssteelbracketwithfixingknobs• 7–pinconnectorforloadcellcable(cableisnotprovided)• 8–pinconnectorforconnectionofPC,Remotedisplay,printerortarepedal(cablenotprovided)• Rechargeablebatterypack(internallyinstalled)• Poweradapter100~240VAC/9VDC800mA
3.2 SELECTINGTHELOCATION
Theweighingindicatorperformsthebestwhenworkinginanenvironmentfreefromaggressiveelements,vibrationsandextremetemperaturechanges.Thesefactorscanaffecttheaccuracyoftheweightreadings.Thescalebaseshouldbeplacedonastablehorizontalsurfaceawayfromvibrationsourcesandstrongmagneticfields.
3.3 CONNECTINGINDICATORTOASCALEBASE
WeighingindicatorSensorika43050(W)connectstothescalebasebya7‐pinBendixBayonetConnectorprovidedbymanufacturer.Loadcellcablefromscalebaseshouldbefixedtotheconnectorprovidedbyelectricalsolderaccordingtotheloadcellcableconnectionchart.(Fig.3).
OPERATIONMANUAL SENSORIKA43050(W)
7
Safetyprecautionsmustbetakenwhilesoldering,suchaswearingsafetyglassesandgloves.Alternatively,lookforaprofessionalorcontactdealertoconnecttheindicatortothescalebase.
NOTE:Sensorikascalebasesareequippedwitha7–pinfemaleconnectorandcanbeeasilyconnectedtotheindicator.
CAUTIONRISKOFELECTRIC
SHOCK
Unauthorizedandimproperuseofelectricsoldercancauseelectricshock
DANGERHOTSURFACE
Riskofsevereinjuriesorcauseafire
PINNUMBER CABLECONNECTIONORDER1 SIGNAL‐2 SIGNAL+3 EXCITATION‐4 SHIELD5 FREE6 EXCITATION+
7 EXCITATION+
Fig.3
Afterconnectorhasbeensoldered,proceedtoconnectthescalebasecabletotheindicator.
BesurethatIndicatorisswitchedoffwhenconnectingordisconnectingloadcellcable.
3.4 CONNECTINGPORTRS232
Soldercommunicationcabletothe8–pinconnectorprovidedaccordingtotheconnectionchart.
PINNUMBER CABLECONNECTIONORDER1 PRINTERCONNECTIONRXD22 PRINTERCONNECTIONTXD23 PRINTERCONNECTIONGND24 TAREPEDAL5 PCORSCOREBOARDCONNECTIONRXD16 PCORSCOREBOARDCONNECTIONTXD17 PCORSCOREBOARDCONNECTIONGND1
8 TAREPEDAL
Fig.4
3.5 AC&DCPOWER
TheSensorika43050(W)runsonACpoweradapterorrechargeablebattery.
ConnecttheACpowercordtoapoweroutlet.ThepowerplugisinEuropeanpowersocketstyle.Pleaseuseasocketadapterifyouwilluseitinotherregionswithdifferentelectricpowersocketstyles.
NOTE:SensorikaTechnologiesdoesnotprovidepowersocketadapters.
Theweighingindicatordisplayshowsthestatusofthebatteryload.Whenthebatteryloadlevelislow,thereisnoloadbarandthebattery‐chargingsymbolblinks.
OPERATIONMANUAL SENSORIKA43050(W)
8
4. OPERATINGTHEINDICATOR
WeighingindicatorSensorika43050(W)isnotsuitableforuseinhazardousareas.
Oncetheindicatorandscalebaseareconnectedandinstalled,followtheCalibrationandSetupmenutoobtainadesiredsettingofthescale.
RECOMMENDATION:Warmupthescalebeforecalibration.Switchthescaleonandletitstayforatleast1hourbeforeenteringthecalibrationmode.
4.1 CALIBRATIONMENUTREE
Fig.5
OPERATIONMANUAL SENSORIKA43050(W)
9
4.2 SETUPMENUTREE
Fig.6
4.3 MENUDESCRIPTION
Sensorika43050(W)hastwodifferentmenus‐CalibrationmenuandCustomerSetupmenu.Enterthesemenususing(PLU)button.
4.3.1 CALIBRATIONMENU
Pressandhold(PLU)buttonuntildisplayshows[PASS]
OPERATIONMANUAL SENSORIKA43050(W)
10
PASS Press(ENTER).Use(RIGHT),(LEFT),(UP)and(DOWN) navigationkeystoenterthepassword505388andpress(ENTER)key.
Use(Right)and(LEFT)navigationkeystonavigatethroughmenu,(ENTER)keytoenterthesub‐menusandconfirmsettings,then(UP)and(DOWN)navigationkeystoselectvalues.Use(U)buttonor[Quit]toescapefromCalibrationmenu.
UNits
Unitssubmenu.Thisfunctionallowsyoutosetup:1.Calibrationweighingunits:U2.Decimalplace:P3.Fullscalecapacity:FS4.Selectionofsingleordoublerange:RANGE5.Scaleweighingdivisions:dd1anddd26.Breakweightfordualweighingmode.
U 0
Calibrationweighingunits.Setupweighingunitstocalibratethescale:kg–0(bydefault)g–1lb–2
p 3
Setupthenumberofdecimalplacesonweighingdisplay:0–0(nodecimalpoint)1–0.02–0.003–0.0004–0.00005–0.00000
FS Fullscalecapacity.Inputthedesiredvalueusingthenavigationkeys.Beawarethatthetotalscalecapacitycannotexceedtheloadcellcapacity.
range 1 Setweighingrange:1‐single2‐dual
Dd1 02 Scaleweighingdivision:01,02,05,10,20,50.Ifyouselectsinglemode,setthisvalueandpress(ENTER)keytoreturntothebeginningof[UNITS]menu.Ifyouselectdualrangemode,proceedtothenextstep.
Dd2 05
Secondaryscaleweighingdivision.Indualmode,youneedtosetupasecondaryscaledivisionandabreakweightvalue.(Example:Ifthescale’stotalcapacityis30kgandyouwanttoweighwithaprecisionof2gupto10kg,andthenaprecisionof5gfrom10kgto30kg,setvaluedd1‐02,dd2‐05andthansetbreakvalue10.000.)
010.000 Setthebreakvaluefordualmodeandpress(ENTER)key.
SiCAL
Linearcalibrationmode.Thismodeallowslinercalibrationtominimizenon‐linearityparameter.Youcanperformupto10calibrationswithinthescale’scapacity.Generally2‐3calibrationsaresufficienttoreducenon‐linearitytotheacceptabletolerancelevelofLegalMetrology(evenonoldscales).Removeweightfromthescale,letitstabilizeandpress(ENTER)key.ItwillcalibratewithZeroweight.
Si- 01
Press(ENTER)again,inputthevalueofyourfirstcalibrationweight,applyweighttothescaleplatform,letitstabilizeandpress(ENTER).Theindicatorwillnowshow[Si‐02].Repeatprocedureforthenextcalibrationweight.Press(LEFT)navigationkeytoreturntotheCalibrationmenu.
OPERATIONMANUAL SENSORIKA43050(W)
11
CAL 1b
Simplecalibrationmode.Thismodeallowssimplecalibrationwhenlinearmodeisnotrequired.Press(ENTER)key,youwillsee6digitsnumberconstantlychanging.Thisvalueisinternalcountingoftheanalog/digitalconverter.ItshowsthatloadcellstatusisOK.Press(ENTER)tocontinue.
ZEro
Calibrationofzero.Removeweightfromthescale,letitstabilizeandpress(ENTER)key.Scalewillcalibratewithzeroweight.Inputthevalueofcalibrationweight,applyweighttothescaleplatform,letitstabilizeandpress(ENTER)key.Scaleiscalibratednow.
Ouit Press(LEFT)navigationkeyuntildisplayshows[Quit].Press(ENTER)keytosavethechangesandexitfromCalibrationmenu.
4.3.2 CALIBRATIONMENU‐ADDITIONALFUNCTIONS
FiLter Indicator’sinternalfiltervalue.Press(ENTER)toview.NOTE:thisisnotafilterusedforperformancespeedadjustment.Forperformancespeedadjustment,seeparameter[FiLter]locatedinSetupMenu.
ICS102 Weightcatchingtime.Factorydefaultis102.
rdS101 Deviationdata.Factorydefaultis101.
rdM101 Increaseddata.Factorydefaultis101.Press(RIGHT)navigationkeytwicetoproceedtonextparameter.
OIML
OIMLsubmenubelongstotheOIMLrequirementsofweighingindicators.[OIML0]–Manualsetting[OIML1]–OIMLautosettings.Choosevalue1toautomaticallysetupbelow3valuesaccordingtotheOIMLrequirements.
rS 02 Percentagerangeofscale’sfullcapacitythatcanbesettozerobypressing(ZERO)button.Valuecanrangefrom0to99%.
Or 16 Percentagerangeofscale’sfullcapacitythatthescaletakesasZerovaluewhenitisswitchedon.Valuecanrangefrom0to99%.
Ot 40 Percentagerangeofscale’sfullcapacityforautomaticZerotracking.Valuecanrangefrom0to99%.
Ouit Parameter[Quit]isusedtosavechangesandescapefromCalibrationmenu.
rESEt IMPORTANT!Thisfunctionresetsallsettingstofactorydefaults.
c1-c2
Dualplatformmodeindicator.Thisweighingindicatorcanbeusedwithtwoplatformssimultaneously(factoryinstallationrequired).Select0touseoneplatformandinvisibledisplayindicator(Fig.2pos.13);select1touseoneplatformandvisibledisplayindicator;select2touse2platformsandvisibledisplayindicator.
OPERATIONMANUAL SENSORIKA43050(W)
12
Adc
[AdcSr]‐Samplingspeed.Factorydefaultis20.[AdcGn]‐Amplifyingrate.Factorydefaultis2.Generallydon’tmakeanychangesinthisparameterunlessyouarefamiliarwiththesoftware.
rSt
Thisparameterisusedtoresetnegativeweighttozerowhenparameter[OIML]isactivated(setto1).(Example:ifparameterOIMLisactivatedandsomedeadweightsuchasscaleweighingpanwasremovedfromtheplatform,itwillshowanegativevaluewhichcannotberesettozerobypressingthe(ZERO)button.Inthiscase,setparameter[rSt]to1andpress(ENTER).Itwillnowsettheweighingvaluetozero).
zero
Thisparameterisusedtoadjusttheminimumdisplayweight.0–1d1–2d2–3d3–4d4–5d5–6d(wheredisscaleweighingdivision)
g1set Factorygravitycompensationvalue.Gravityvalueattheplacewherethescaleiscalibrated.
G2set Customergravitycompensationvalue.Gravityvalueattheplacewherethescaleisused.Ifitisusedattheplacewhereitwascalibrated,[g1Set]and[g2Set]shouldbethesame.
4.3.3 SETUPMENU(CUSTOMERSETTINGS)
Press(PLU)button,displaywillshow[PLUPro].
4.3.3.1 CHECKWEIGHINGFUCTIONSETUP
pLUPro ThisparameterisusedtosetupCheckweighingvaluesandstoretheminmemoryforupto20differenttargetweights.Press(ENTER)keytobegin.
PLU 01 Firsttargetsettings.Press(ENTER)tocontinue.
tAr
Hi
Lo
[tAr]willappearshortlyandthenindicatorrequiresaninputoftargetvalueusing(RIGHT),(LEFT),(UP)and(DOWN)navigationkeys.Press(ENTER)whenfinishinginput.Input[Hi]and[Lo]values.Thesearetheabsolutevaluesofthedifferencesbetweentargetweightandhigh/lowallowedweights(Example:targetweight=1.0kg,maximumallowedweight=1.1kg,minimumallowedweight=0.9kg.[Hi]=1.0–1.1=‐0.1=0.1kg,[Lo]=1.0–0.9=0.1kgSetup[Hi]=0.1and[Lo]=0.1.)Generallythesevaluesarethesamebutyoucaninputdifferentvaluesifrequired.
Btype1 Selectalarmmode:1–weightwithinrangealarm
OPERATIONMANUAL SENSORIKA43050(W)
13
2–weightoutofrangealarm.
bNode3
Selectauditablealarmtype:1–alarmdisabled2–beeponce3–continuousbeeps.Press(ENTER)key.Displayshows[PLU02].Proceedtothenextsetpoint.
4.3.3.2 PIECE‐COUNTINGFUNCTIONSETUP
Tosetuppiececounting,firstselectpiece‐countingmodeusing(U)button.Thecountingmodeindicatorappearsontherightsideofthedisplaywindow(fig.2,pos.10).Pressandhold(U)buttonformorethanasecond,aflushingnumber10willappear.Setupthesamplequantityyouwanttouse,from10to100(forsmallitemsaslargersamplequantitymoreprecisethecountingoperation)thanpress(ENTER).Thesamplevaluewillcontinueflushingfor5secondsthanstops.Yourscaleisreadyforpiececounting.
NOTE:Youloseyoursamplesettingswhenthescaleisturnedoff,unlessyousavethesampleweightsinmemory.
Youcansaveupto100samplevaluesinmemoryofweighingindicator.
Whenthescaleisinpiece‐countingmodeandsamplevaluealreadyconfigured,press(PLU)buttononce,displaywillshow[PLUPro].Use(RIGHT)navigationkeytoreach[CLUPro],press(ENTER)key.
CLU 01 Usenavigationkeystoselectthememorynumberwherethesamplevaluewillbestored,press(ENTER)tosave.Yourindicatorreturnsto[CLUPro]parameterafterthesampleweightisstored.
Torecallastoredsamplevalue,entertopiece‐countingmodeusing(U)button,thenpressandhold(B/N)buttonuntildisplayshows[CLU01].Inputamemorynumberwherestoreddesiredvalueandpress(ENTER).
4.3.3.3 DIGITALTAREFUNCTIONSETUP
Placethecontainerorotherobjectthatyouwanttotareandpressthe(TARE)button.Thescalewillthentaketheobjectastareanddisplaythenetweight.Press(B/N)buttontotogglebetweenGrossweightandNetweight.
Sensorika43050(W)canstoreupto20digitaltaresintheindicator’smemory.ThisfunctionisveryusefulwhenGrossandNetweightarebothrequiredbutitsimpossibletoseparatetheproductsfromtheirpackaging(bucket,pail,pallet,etc).Iftheweightofpackagingisknown,itcanbemanuallystoredintheindicator’smemoryandbeusedlater.Followthesestepstosavedigitaltaresinmemory.
Press(PLU)button.Use(RIGHT)navigationkeytoreach[tLUPro].
Torecalladigitaltarefromthememory,pressandhold(TARE)buttonuntil[tLU01]messageappears.Selectthenumberofmemorywhereyourdigitaltareisstoredandpress(ENTER).Thetarevaluewillbedisplayed.
tLUPro
Press(ENTER),selectoneofthe20memoriesdesignatedfordigitaltares,press(ENTER)again,enterthevalueofdigitaltareyouwishtostoreandpress(ENTER)tosaveit.Yourindicatorwillnowreturnto[tLUPro].Repeatthesameprocedureifyouwishtostoremoretares.
OPERATIONMANUAL SENSORIKA43050(W)
14
4.3.3.4 HOLDFUNCTIONSETUP
HoLd
Holdsubmenuhas5valuestoselect:0–holdfunctionisoff.1–indicatorcapturespeakvalues.Press(ZERO)buttontodropvaluetozero.2–indicatorcapturesvaluewhenweightisstable(stabilityindicatorison).Press
(ZERO)buttontodropvaluetozero.3–holdfunctionactivatestogetherwithstabilityindicator.Weighingindicatorholds
thevaluewhenweightisontheweighingplatform.Onceweightisremoved,displayreturnstozero.
4–holdfunctionactivatestogetherwithstabilityindicator.Weighingindicatorholdsthevalueevenwhenweightisremovedfromtheweighingplatform.Newholdvalueappearswhenanewobjectisplacedontheweighingplatform.
4.3.3.5 AUTOTAREFUNCTIONSETUP
Sensorika43050(W)canautomaticallytaketheweightofrecipientastare,weightheproductandresetscaletozerooncetherecipientwithproductisremovedfromtheplatform.
Press(PLU)button,scrollmenuwith(RIGHT)keyuntildisplayshows[AUt–t],press(ENTER)andselect1toenableAutoTarefunctionorselect0todisableit.
4.3.3.6 FILTERFUNCTION
FILter
Thisfunctionisusedtoadjustthesensibilityofthescale.Filtersubmenuhas6filterlevelstoadjust.0‐Scaleresponseisveryfastbutitcanbeunstableifscaledivisionissmall.Optimumfordynamicweighing.6–Scaleisverystablebuttheresponseistooslow.Optimumforunstableweighingobjectssuchasliquidsoranimals.Youshoulddecidetheappropriatefilterlevelbasedonyourimplementation.
4.3.3.7 ANIMALWEIGHINGFUNCTION
Sensorika43050(W)doesn’thaveaspecialsubmenuforanimalweighingbutitcanbeeasilysetupbycombiningtwofunctions‐HoldandFilter.SettheHoldfunctiontolevel4andFilterfunctiontolevel4,5or6dependingonanimalweight.Nowyoucanuseyourscaletoweighanimals.
4.3.3.8 BACKLIGHTFUNCTION
bL-SET
Selectoneofthe3availableoptions:On–backlightalwayson.Off–backlightalwaysoff.Auto‐backlightautomaticallyswitchedoffafter5secwhenstabilityindicatorappears.
4.3.3.9 SOUND(BEEP)FUNCTION
Insubmenu[bEEP],select1toactivateaudiblekeypadsoundorselect0todeactivateit.
OPERATIONMANUAL SENSORIKA43050(W)
15
4.3.3.10 AUTOPOWEROFFFUNCTION
Whendisplayshows[AUt‐0]press(ENTER)key.
oFF-3
Autooffmodecanbesetbetween0and4.0–autoofffunctionisdisable1–offafter2minwithoutuse2–offafter3minwithoutuse3‐offafter5minwithoutuse4‐offafter10minwithoutuse
4.3.3.11 COMUNICATIONWITHPRINTERORPC
ScrollSetupmenuuntildisplayshows[uArt],press(ENTER)key.
Br 001
Thefirstparameter[brXXX]isusedtosetcommunicationspeed(bauds)tofollowingvalues:001–1200002–2400004–4800009–9600019–19200038–38400057–56800058–115000
Followingparameters[dbit]and[PAri]arefixedandcannotbemodified.Theseparametersshowthelengthoftransmittingprotocolandparity.
Adr
ThisparameterisusedtosetthemodeoftransmittingofcommunicationprotocolforRemotedisplayorPC.0–transmittingisdisabled1–normaltransmittingconstantly2–inversetransmittingbydemandusing(ENTER)navigationkey3–inversetransmittingconstantlyParameters2and3areforscoreboardcommunication.
4.3.3.12 SETUPPRINTINGFORMAT
Fivedifferentprintingformatsinfourlanguagescanbeselectedinsubmenu[PrnFrM].
PrFM Usenavigationkeystoselectprintingformat.Press(ENTER)toconfirm.Seebelowexamplesofprintingformats.
Format1:
Format2:
OPERATIONMANUAL SENSORIKA43050(W)
16
Format3:
Format4:
Format5:
OPERATIONMANUAL SENSORIKA43050(W)
17
LFn 01 Setnumberofemptylinesbetweentheprinteddatablocks.Valuecanrangebetween00and99.
LAn 0
Selectoneofthefourlanguagesforprinting:0–English1–Spanish2–French3–German
4.3.3.13 A/DCONVERTORTEST
ICount DiagnosticofAnalog/Digitalconverter.Press(ENTER)toview.
Youwillseesixdigitsandsomeofthemareconstantlychanging.ItshowstheAnalog/Digitalconvertorisfunctioning.Thisinformationisusefulfortechnicaldiagnosticofweighingindicatorandloadcell.Inmostcases,ourTechnicalDepartmentisabletodiagnoseindicatororloadcellfailurewiththis6‐digitsnumberprovided.
4.3.3.14 WEIGHINGUNITSENABLING/DISABLING
Navigatetosubmenu[Unit].Thereare3weighingunitsthatcanbeenabledordisabled:lb,ozandcountingfunction.Setvalueto0todisable;1toenable(defaultunitiskgcannotbedisabled).
4.3.3.15 TIMEANDDATESETTING
Thisfunctionisanoptionalfeatureandcanberequestedfrommanufacture.
Navigatetosubmenu[rtc].
tImE Displaywillshow[tImE].Press(ENTER)keytosetuptime.Sixdigitstimeformatwillappear.Press(ENTER)forthenextstep.
dAtE Displayisshowing[dAtE].Press(ENTER)keytosetupdate.Sixdigitsdateformatwillappear.Setdateformatandpress(ENTER)toconfirm.
4.3.4 ADDITIONALKEYFUNCTIONS
4.3.4.1 WEIGHTACCUMULATION
Sensorika43050(W)canaccumulateweightvaluesondemand.Whenaweightisappliedtotheplatform,press(M+/RIGHT)navigationkey.Theweightoftheloadwillbestoredinmemoryoftheindicator.Removeweightfromtheplatform.Checkthatthedisplayreadingshowszero,applyanewweightandpress(M+/RIGHT)keyagain.Thenewweightwillbeaddedtothepreviouslyvaluestoredin
OPERATIONMANUAL SENSORIKA43050(W)
18
memory.Youcanaccumulateasmanyweightsasyouneed.Toseetheaccumulatedweight,press(MR/LEFT)key.
Toerasetheaccumulatedweightfromthememory,firstpress(MR/LEFT)keytodisplaytheaccumulatedweight,thenpress(UP)keyfollowedby(DOWN)key.Theaccumulatedweightisnowerased.
4.3.4.2 LOCKKEYBOARD
Tolockthekeyboard,pressandhold(ENTER)keyuntilmessage[Loch]appearsonthedisplay.Tounlockthekeyboard,pressandhold(ENTER)keyagainuntil[UnLoch]messageappears.
Mostkeysaredisabledwhenkeyboardislocked.
5. LIMITEDWARANTY
SensorikaTechnologiesproductsarewarrantedagainstdefectsinmaterialandworkmanshipfromthedateofpurchasethroughthedurationofthewarrantyperiod.Duringthewarrantyperiod,SensorikaTechnologieswillrepairor,atitsoption,replaceanycomponent(s)thatprovestobedefectiveatnocharge.
Thiswarrantydoesnotapplyiftheproducthasbeendamagedbyaccidentormisuse,exposedtoradioactiveorcorrosivematerials,penetrationofforeignmaterialstotheinsideofproduct,orasaresultofserviceormodificationmadebyanyoneotherthanSensorikaTechnologiesoritsauthorizeddistributorsand/orservicecenters.
6. SHIPPINGINFORMATION
Indicatorweight 2.20kg
Shippingpackingdimensions 26cmx26cmx15cm
Shippingweight 2.50kg