instructional material specification ?· instructional material specification information ......

Download INSTRUCTIONAL MATERIAL SPECIFICATION ?· instructional material specification information ... h—2-pin…

Post on 27-Aug-2018

212 views

Category:

Documents

0 download

Embed Size (px)

TRANSCRIPT

  • INSTRUCTIONAL MATERIAL SPECIFICATION INFORMATION

    Document

    PART NO. ECN FOLDER FILE NAME

    48049-183-03 613A 48049-183-03_K613A 48049-183-03_Eng.book

    48049-183-03_Spa.book

    48049-183-03_Fre.book

    Cover Art

    File Name Loc. Folder

    06135014 CR Artwork

    Rev. ECN Date By Rev. ECN Date By PART NO.: See Table

    Drawn: BIL Chkd: MFJ Date: 070103 ECN: 613A

    Name: Full-function Test Kit

    Prints to: A SHEET 1 of 1

    A48049-183

    NOTES:

    1. Layout: Print one-sided to two-sided.2. Stock: Cover: 10 pt. coated one side. Body: 50# offset paper, 8-1/2 x 11 in. finished size.3. Binding: Perfect bound. Drill holes to fit standard three ring binder.4. Square D to provide electronic file; do not typeset.5. Vendor to supply proof to Square D Technical Documentation prior to initial printing and for any modifications

    thereafter.6. Square D P.O. number and ECN level must accompany each shipment.7. Date of printing, part number, quantity and vendor ID must be stamped on each package.8. To be printed in black and white.

    TC FORM 034REV. 07/00

  • Full-function Test Kitv 1.0

    Equipo de pruebas de amplias funciones (maleta de pruebas)v 1.0

    Trousse dessai des fonctions compltes (mallette test)v 1.0

    Instruction Bulletin

    Boletn de instrucciones

    Directives d'utilisation

    Retain for Future Use. / Conservar para uso futuro. / conserver pour usage ultrieur.

  • Full-function Test Kit

    v 1.0

    Instruction BulletinRetain for future use.

  • HAZARD CATEGORIES AND

    SPECIAL SYMBOLS

    Read these instructions carefully and look at the equipment to become

    familiar with the device before trying to install, operate, service or maintain

    it. The following special messages may appear throughout this bulletin or on

    the equipment to warn of potential hazards or to call attention to information

    that clarifies or simplifies a procedure.

    The addition of either symbol to a Danger or Warning safety label

    indicates that an electrical hazard exists which will result in personal injury if

    the instructions are not followed.

    This is the safety alert symbol. It is used to alert you to potential personal

    injury hazards. Obey all safety messages that follow this symbol to avoid

    possible injury or death.

    PLEASE NOTE Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by

    Schneider Electric for any consequences arising out of the use of this

    material.

    FCC NOTICE This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits

    are designed to provide reasonable protection against harmful interference

    when the equipment is operated in a commercial environment. This

    equipment generates, uses, and can radiate radio frequency energy and, if

    not installed and used in accordance with the instruction manual, may cause

    harmful interference to radio communications. Operation of this equipment

    in a residential area is likely to cause harmful interference in which case the

    user will be required to correct the interference at his own expense. This

    Class A digital apparatus complies with Canadian ICES-003.

    DANGERDANGER indicates an imminently hazardous situation which, if not

    avoided, will result in death or serious injury.

    WARNING

    WARNING indicates a potentially hazardous situation which, if not

    avoided, can result in death or serious injury.

    CAUTION

    CAUTION indicates a potentially hazardous situation which, if not

    avoided, can result in minor or moderate injury.

    CAUTION

    CAUTION, used without the safety alert symbol, indicates a potentially

    hazardous situation which, if not avoided, can result in property damage.

    Provides additional information to clarify or simplify a procedure.

    EN

    GL

    ISH

  • 48049-183-03 Full-function Test Kit

    07/2003

    20012003 Schneider Electric All Rights Reserved 5

    EN

    GL

    ISH

    TABLE OF CONTENTSFull-function Test Kit Identification ...........................................................6

    Technical Specifications.....................................................................7

    Determining Trip Unit Compatibility....................................................7

    Connections .............................................................................................8

    Connecting Power Cable....................................................................8

    COMPACT NS Circuit Breakers Equipped with STR Trip Units ......8

    MICROLOGIC and ET Trip Units .....................................................8

    Power-on Test..........................................................................................9

    Language Selection ...............................................................................10

    From Full-function Test Kit Title Screen ...........................................10

    From Select Test Kit Function Screen..............................................10

    Secondary Injection Testing...................................................................11

    Secondary Injection Test Setup Procedures ....................................11

    Configuring Circuit Breaker Parameters.....................................11

    Automatic Trip Curve Test (All Trip Units Except STR22ME

    and ET1.0I).......................................................................................14

    Configuring Protection Parameters ............................................15

    Configuring Automatic Trip Curve Test ......................................15

    Saving Test Files ........................................................................16

    Automatic Trip Curve Test (STR22ME Trip Unit Only).....................17

    Configuring Protection Parameters ............................................17

    Configuring Automatic Trip Curve Test ......................................18

    Saving Test Files ........................................................................19

    Automatic Trip Curve Test (ET1.0I Trip Unit Only)...........................19

    Manual Trip Curve Test (All Trip Units Except STR22ME) ..............20

    Saving Test Files ........................................................................21

    Manual Trip Curve Test (STR22ME Trip Unit Only).........................22

    Saving Test Files ........................................................................23

    Mechanical Operation Trip Test .......................................................24

    Zone-selective Interlocking Test ............................................................25

    Inhibit Functions.....................................................................................27

    Ground-fault Inhibit...........................................................................27

    Thermal-imaging Inhibit....................................................................29

    Viewing and Deleting Test Files.............................................................31

    Viewing Previously Saved Test Files ...............................................31

    Deleting Previously Saved Test Files...............................................32

    Deleting One Saved Test File.....................................................32

    Deleting All Saved Test Files......................................................33

    Configuring Full-function Test Kit Options .............................................34

    Language Selection..........................................................................34

    Setting Display Screen Backlight .....................................................34

    Setting Display Screen Contrast ......................................................34

    Maintenance ..........................................................................................35

    Fuse Replacement ...........................................................................35

    Calibration ........................................................................................35

    Cleaning ...........................................................................................35

    Troubleshooting .....................................................................................36

    General Errors..................................................................................36

    Error Messages................................................................................38

    Glossary ...........................................................................................39

  • Full-function Test Kit 48049-183-03

    Full-function Test Kit Identification 07/2003

    20012003 Schneider Electric All Rights Reserved6

    EN

    GL

    ISH

    FULL-FUNCTION TEST KIT IDENTIFICATION

    Figure 1: Full-function Test Kit and Case Contents

    APower Cable Receptacle

    BPower Switch

    CLine Fuse Holder and Voltage Selector

    DModbus Serial Connection

    ETrip Unit Test Cable 10-pin Port

    FInterface Screen

    GKeys

    H2-pin Test Cable (STR Trip Units)

    I7-pin Test Cable (MICROLOGIC Trip Units)

    J10 A Filtered Power Cable

    A

    B

    C

    D

    E

    H

    F

    G

    06

    13501

    4

    J

    I

    061

    3495

    4

    0613

    4953

    061

    3511

    306

    1351

    12

  • 48049