intelligent toilet manual - secure.img1-ag.wfcdn.com

14
Intelligent Toilet Manual

Upload: others

Post on 15-May-2022

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Intelligent Toilet Manual - secure.img1-ag.wfcdn.com

Intelligent Toilet Manual

Page 2: Intelligent Toilet Manual - secure.img1-ag.wfcdn.com

Manual List Thanks very much for using our products.

Please read and follow the instructions carefully before using.Save the instructions in proper place and do not loss it.

There would be a little difference from each item. The shape is subject to the real product.

The shape of item in the manual is for reference only.

List of Functions & ConfigurationsSafety Guide

Safety Note

Attention in Using

Name of PartsLED Display Description

Before Using

Instructions

Remote Control

How To UseOperating Note

Routine MaintenanceDaily Cleaning

Cleaning After Cover Dismantled

Not Use in Long Time

Bettery Replacing

In Case of Freezing

Problem & Solution

Specification

Page 3: Intelligent Toilet Manual - secure.img1-ag.wfcdn.com

1. Do not use the product in wet environment.2. Do not drop the remote control into bath tub or sink or any liquid.

Main Functions Safety Notes

Bidet

Rear Cleaning

Moving Spray

Massage

Position Adjusting

Cover Heating

Warm Wind Drying

Deodorization

Soft Close

Smart Sensor

Smart Flushing

Nozzle Self-cleaning

Energy Saving

Pressure Adjusting

Instant Heating

Power Cut Flushing

Automatic Cover

Temp. Protection

Foot Sensor Flushing

Foot Sensor Cover

Rear cleaning by output water from nozzle

Bidet cleaning for ladies

More cleaning effective by moving nozzle

Massage by rhythmed water pressure

Automatic drying after cleaning

The soft hinge device help to keep quiet

The position of nozzle can be adjusted to forward and backward

The cover can be kept in comfortable temp. by mico CPU control

The foul smell can be dispelled by the deodorization fillter

The toilet will stand by while people seat on the inductive area

Auto flushing will be run after leaving the seat (kept seating for 10 sec) or drying or in one-key mode The nozzle will clean itself while it start to run or be end of working

There is energy saving mode while the toilet is not in use

Increasing the water pressure would get better effect of cleaning

The water can be heated to setting temp. instantly

The flushing still can be run while the power is off

The cover will open itself while people is in front of it in about 30cm (only for type-C product)The cleaning function will be stopped while the water is cut inorder to avoid scaldThe flushing will run once time while the foot meeting the area of sensor at the bottom of right side (only for type-B product)

The cover will open itself while the foot meeting the area of sensor at the bottom of right side (only for type-C product)

TypeFunction

Functions For Each TypeRear Bidet Move Warm

seat

Positionadjust

Softclose

Smart

flush

Pressadjust

Nightlight

Instantheating

Seatsensor

Autocover

Power

-cutflush

Footsensorcover

FootsensorflushWarm

wind

NozzlecleanPow

ersavingSpa

Deodori-zation

Attn: The manual of panel as below is for full functions. The acctual functions are base on the real product.

Please read and follow the instructions carefully before installation and using.

The instructions must be followed while using the product.

3. Do not put water onto product or electric plug.

1. It requires someone to accompany while using the product if people who can not adjust the temperature correctly as like as children, elder, disabled, paraplegia, etc.. And please set the temp. to lowest level or shut the function down. 2. The product includes functions showed in this manual only. Please do not use the extra devices unless we recommend.

3. Do not replace the wire or electric plug yourself while it is broken or dropped into water. The correct way is to call the professional maintenance staff to handle it or send it to maintenance center.

4. Please ensure the wire would not be burnt. 5. Please do not use the product if you take sleeping pills or over

drinking or weary or drowsiness.

The old fittings and hose can not be reused.

6. Please do not put anything into the opening or tube. 7. Please do not use the product outdoors. 8. Please do not allow children play the product as toy. 9. Please use the new fittings and hose we supply.

-Aovid accident of electric shockWARNING

-Aovid accident of scald, electric shock and fireWARNING

Please Keep The Manual Well

Page 4: Intelligent Toilet Manual - secure.img1-ag.wfcdn.com

with lots sockets

product are forbidden

Safety Notes

Warning

Warning

Warning

WarningPlease do read and follow the instructions carefully before using. They are about safety of person.

It is forbidden to drop the water and detergent on the

Do not use the product in wet environment

Dismantl, repair or remould the with wet handDo not touch the electric

wire connected toiletDo not damage the electricStop using the product while it

PREVENT GET HURT IN BURNS

Do not use the unsteady socket

Do not use the power socket

220vDo not use the AC except Do not use water sources other

than city water

malfunction

product or electric plug.

Smart toilet is electric product. Please avoid splash and do not use it in wet environment. Maintain air circulation if using theproduct is used in bathroom.

Ignoring this tag may cause Dismantling is forbidden.

Must follow.

serious injury or death.

Ignoring this tag may cause injury

May cause fire or electric shock.

May cause fire or electric shock.

May cause fire or electric shock.

May cause fire or electric shock. May cause electric shock.

May cause fire or electric shock.

May cause dermatitis.

Please set the seat temp. to home temp.if seating in a long time.

Please set the seat temp. to home temp.and set the drying temp. to lowest levelfor special people.

May cause fire.

Please pull out the plug and shut the inlet valve.

Keep using the product while it malfunction may cause fire or electric shock or leakage.

Ignoring the breakage to keepusing product would cause fire, electric shock or short circuit.

Do not remould the wire we supply. That would cause fire or electric shock.

Malfunction:LeakageDehiscenceAbnormal sound & smellFuming & abnormal heatingBlocking

Do not pull or process or heat orforcefully bend the electric wireconnected toilet.

The people who can not adjust the temperature correctly as like as children, elder, disabled, paraplegiaetc..

The people who take sleeping pillsor over drinking or weary or drowsiness

Do not put heavy weight ontothe electric wire connected toilet.

May cause electric shock without ground wire.

May cause fire or lectric shock without waterproofing.

Attn: The electric resistance should be 4Ω and the diameter of the copper wire should be 1.6mm or above.

May cause fire or electric shock if not follow the instructions.

socket. Or use insulated transformer (>1.5KVA, <3.0KVA).a. Please use a high-sensitivity and fast leakage switch for the circuit of the electrical

away from the bath tub.a. The electrical socket should be installed up to ground for 0.3m at least and stay

May cause breakage or leaking.

or property loss.

No splash

Warning

Caution

Meaning of tag

Set the electrical socket as below

Must install the ground wire

Using the product in bathroomMake sure the power plug has been waterproofed with silica gel.

Instruction of tag

No wet

No wet hand

Forbidden Forbidden

Forbidden

Forbidden

disassemblyNo

Forbidden

Forbidden

Must follow

Page 5: Intelligent Toilet Manual - secure.img1-ag.wfcdn.com

on it

Warning

No fire

Do not allow any fire thing get close to the product

Do not block the outlet of warm windPlug the electric plug well

Please pull out the electric plug while the toilet is blocked

Do not show the product into direct sunlight

Reuse untill the blockage is clearedDo not impact the product stronglyDo not stand on the product or put heavy weight

The surface can be cleaned neutral detergent onlyDo not use the things as below

Do not dismantle the inlet Do not bend the tubefillter while the inlet valve

Do not drop litters into the toilet bowl

Cut the power if the product Close the inlet valve while

Prevent the damage of

Please keep proper home temp.

freezing

it is leaking

Tighten the inlet valve

not in use in a long time

is on

May cause fire.

May cause fire, electric shock or breakage.

May cause fire if the plug is unsteady or not plugged well.Pull out the electric plug if the product not in use in a long time

May cause leakage while running the cleaning function if not pull out the

May cause damage of discoloration, aging and deformation.

electric plug.May cause breakage or injury.

(Bath detergent, domiciliary detergent, petrol, thinner, cleaning powder, nylon brush, etc.)

May cause leakage.

May cause breakage or injury.May cause leakage.

May cause leakage.

May cause leakage.

May cause block & leakage.

Pull out the plug for safety.May cause dermatitis by rancid

The inlet device and part of prodcut would be damage byfreezing and cause leakage.

May cause leakage if not to do.

water.

Pay attention while children or elder is using the product.Forbidden

Forbidden

Forbidden

Forbidden Forbidden

Forbidden

Must follow Must follow

Must follow

Must follow

Must follow

Must follow

Must follow

Page 6: Intelligent Toilet Manual - secure.img1-ag.wfcdn.com

Using Notes Using Notes

Wrong cleaning way

Routine maintenance

Attention of operation

Do not lay your back on the cover

Take the cover for children away after using

Do not wipe the product with Flushing directly is Please prevent the freezing in winter

The heating apparatus should stay awayfrom the product.

to avoid damage.forbiddendry cloth or toilet paper.

Do not urinate on the nozzleor product.

Do not cover the sensor area of

May cause wrong actions.

May cause breakage.

May cause discoloration and error.

Please open the cover lid and cover seatgently.

May cause breakage and error.

May cause some functions can not run.

May cause much noise.product and remote control.

Radio or similar products should stay away from the toilet.

Pull out the electric plug ifthunder.

Page 7: Intelligent Toilet Manual - secure.img1-ag.wfcdn.com

00℃

Name of Parts LED Display

Knob Manual

Smart cover

Cover

Safety notes

LED display

Seat sensor area

Seat temp.

Temp.

Water temp. Seat temp.

Home temp.

Saving mode

Square LED Display

Round LED Display

Energy saving

Saving

Water temp. Home temp.

Nozzle

Ceramic bowl

Safety plug

Inlet valve

Inlet tube

Control knob

Contrarotating:Rear/Moving cleaning

Mid:Stop/Drying

Clockwise:Bidet/Moving cleaning

Page 8: Intelligent Toilet Manual - secure.img1-ag.wfcdn.com

Before Using Before Using

Warning

Warning

Caution

Please confirm things as below before

1. Plug in 220V AC socket. 1. The nozzle, water pipe and tube should not be leakage.

2. The light of “saving mode” on LED display should be off while the seatsensor area is covered.

3. Check the rear & bidet washing,

4. Check the damping is well or not.

defecation assist, deodorization and

1. The washing function is for instantheating type.

2. Ensure the inlet valve is opened and the inlet tube is not bent afterthe product is booted.

May cause fire if ignore this warning

The function would be out of workif the water inlet is error.

drying function is well or not.

1. Please test once time each month

2. Press the “test” button 3. Confirm that the “pilot light” is off4. Confirm that the product is out of work5. Press the “reset” button to boot the

the poduct if every steps as above areOK.

Keep pressing the “defecation” key onremote control until the temp. light is to be red before plugging in 220V socket.Keep pressing until the temp. light is tobe blue. Then the pair code operation is done.

2. Please confirm the light of temp. is

2. Please confirm the inlet valve is

Confirm that the seat sensor is on workingand the light of “saving mode” or the pilot light is off before checking the function ofwashing, drying and deodorization.

opened or not

on or not.

Plug

Seat sensor

Pilot lightTest

Reset

With ground wire

using the product at first time.

Plug well

Please make sure tighten the gound wire.Please contact electrical installation company if your socketis without ground wire.The original electric plug is for triple electrode type. (with ground wire)Take care the electric shock while the product is out of work.Ensure the installation of water pipe, tube and valve is well, otherwise thatwould cause leakage and loss.

Pair Code Confirm each function

Leakage Protected Plug

Only 220V AC is accepted.Please follow the relevant regulations for wiring.

Page 9: Intelligent Toilet Manual - secure.img1-ag.wfcdn.com

Press button can adjust the temp. in 4 cyclic levels: high, mid, low & home temp..Seat temp. adjustingPress button can adjust the temp. in 4 cyclic levels: high, mid, low & home temp..

Keep pressing the power button on the remote control or side knob in 3 seconds

Seat

Rear

Drying

WaterTemp.

Drying Temp.

SeatTemp.

Light Massage

Strength

Position

Bidet

Flush

Cover

Remote Control Operation

Pair Code from remote control to toilet

Step 1: Cut off the power.

Step 2: Keep pressing the “defecation” key on remote control until the temp. light is to be red before plugging in 220V socket. Keep pressing until the temp. light is tobe blue. Then the pair code operation is done.

Power key

withoutseating to boot the product. The icon on the display and the side knob will

Water temp. adjusting be light. Press the power button again to shut down the product.

Press the button again to stop.

Drying temp. adjustingPress button can adjust the temp. in 4 cyclic levels: high, mid, low & home temp..Rear washingPress button to boot the function.Bidet washingPress button to boot the function.MassagePress button to adjust the water pressure and temp. automatically while the rear or bidet washing is working.

Moving washing

Nozzle positon adjusting

Press “rear” or “bidet” button to boot the moving washing while the rear or bidet function is running. The nozzle will move forward and backward.Press same button to stop moving.

Press button to adjust the position of nozzle for forward and backward while the rear or bidet function is running. Water pressure adjustingPress button to adjust the water pressure to be stronger or weaker whilethe rear or bidet function is running. DryingPress button to run the drying function and it will stop itself in 3 mins.

DeodorizationThe deodorization will run itself after people seating on the cover and it will stop in 30s after people leaving the seat. It will not work while the drying function is running.StopPress button to stop the function which is running.Nozzle cleaningTurn the knob to “rear” key and clean the nozzle after it comes out.The nozzle will be back to original position in 5 mins. You also can press button.Nozzle cleaningPress button to open/close the night light & knob light periodically.

Page 10: Intelligent Toilet Manual - secure.img1-ag.wfcdn.com

Keep press button for 3s to close the cover seat and cover lid.

Press button on remote control to set the automatic cover on/off.

Instant heating device ensure the steady water temp..

The washing functions would not run by operation in error if no people seating on the seat sensor area.

No people seating on the seat sensor area.

The effect of heating base on theoutlet water temp.. Seat Sensor

The seat sensor would not work if:

Instant

Normal: No heating

Press button to flush once. The flushing will boot itself after leaving the seat.

Inductive open/close cover (only for type-C)

Low : About 35Mid : About 38High : About 41

Manual Using Notes

Water Temp.

Capacity

Water temp. base onlevle setting

Seat SensorBoot rear/bidet/defecation while seating on cover, the flushing will boot itself

While the function is running, the cover will open itself when people get close

Press button once to open cover lid and press again to open cover seat. Remote control open cover

That would not work if people is seating on the cover.Remote control close cover

That would not work if people is seating on the cover.

When the cover lid is open only, it will close itself in 150s without flushing.Auto open/close cover

When the cover lid and cover seat are open, they will close themselves in 150sand the flushing will be run once.

The cover will open while the foot catch the sensor area at right side on Foot sensor

bottom. Operating again to close cover. (only for type-C)

Flushing once while the foot catch the sensor area. (only for type-B) Type-A is without foot sensor function.

and the flushing will be run once.

The energy saving mode will be booted in 3min after people leaving the seatAuto energy saving

without any operation. The water & seat temp. will be set to low level untilpeople seat on the cover again.

to toilet less than 35cm. And the cover will close itself without any operation or people leave the seat in 150s.

after the operation is done.

Page 11: Intelligent Toilet Manual - secure.img1-ag.wfcdn.com

Using Notes Maintenance

Energy Saving Water flow out ?

Maintenance of Smart Toielt

Maintenance of Nozzle

Warning

Warning

Close Cover Softly

That would save energy as below That would be normal that Please do pull out the electric plug and confirm the pilot light is off

Please use soft cloth combine clean waterPlease wipe the product often with wet soft cloth in case of the dirt istoo hard to clean out. In addition, the wet soft cloth can avoid the static to adsorb dust and cause the product dirty.The cover can be dismantled for easily cleaning.

Please clean the nozzle with soft brush.Turn the knob key until the nozzle is outafter leaving the cover seat.Do not pull out and bend the nozzle by

Please often clean the dust on the electric plug. Clean the plug with dry cloth after pull it out of socket.

Poor insulation may cause fire.

force.

Must follow

before maintenance.some water flow out from the nozzle before/after washing or while the water temp. setting is

Please close the inlet valve and pull out the plug if the water keep flowing out besides the situations as above. And you need to contact the agency.

on.

Close the cover after usingDo not set the high level for temp.

Set the suitable temp. base on

Use the energy saving device as

Cut the power if the product will

Prevent the freezingbe not in use for a long time

much as possible

The soft-close device would avoidthe noise of cover colsing

seasons and air temperature

every time

Page 12: Intelligent Toilet Manual - secure.img1-ag.wfcdn.com

Cover Cleaning Not in use

Replacing Battery

Caution

How to dismantle the coverMust clean up the water for situations as below

1. Pull out the plug

1. Must pull out the plug

2. Must clean up the water in toilet May cause electric shock if not to do

May cause the fittings damage by water if not to do

3. Do not extrud the wire and tubeMay cause electric shock or leakage

4. Handle with care while dismantling the cover to clean May cause leakage and error

5. Do not put the cover upside down and put on the ground without pulling out the plugMay cause damage of surface and error

6. Please do mark and remember the position of installation for each water tube you are willing to dismantle.Tighten the connecting parts to avoid leakage.

3. Lift the cover up 4. Put the cover on the cushion

Be care of the nozzle and drying baffle

Pull out the three tubes on washing valve

Do not put the cover upside down.Do not put the cover on the ground.

2. Close the inlet valve

The product will be not in use for a long time that would cause blockage

Must close the inlet valve before dismantling

The pilot light will be getting light or offReplacing battery of remote controland the signal can not be transmitted

when the battery is almost done. Open the back cover of

Alkaline battery

Back cover

remote control and replacetwo 1.5v AAA alkaline battery

The service life of battery we supply will be very shot cause it is mainly for checking conditions of running in the installation.

Ensure the position of positive pole andnegative pole is correctThe new and old batteries can not be mixed togetherPlease use alkaline battery

Ensure correct installation of inlet tubeMay cause leakage easily

inlet tube

by polluted waterThe product will be freezing and leakage cause by falling temperature inuninhabited house

Page 13: Intelligent Toilet Manual - secure.img1-ag.wfcdn.com

Freezing Damage Fault Judgment

Fault Reason Method

The smart toilet will be damage and leakage cause byThere are some simple faults can be fixed easily.Please confirm matters as below before sending the product tomaintenance center.

power of socket is off

power of product is off

no plug in socket

leakage of electric

inlet valve is closed

inlet tube is blocked

out of seat sensor area

the nozzle is blocked

low water pressure

not set the proper water temp. yet

presse water temp. button and seta proper level

presse seat temp. button and seta proper level

run washing for a while and checkafter a period of time

not set the proper seat temp. yet

blocked by dust

Please contact the after-sales centre if the faults still can not be fixed.

clean the part of deodorization

temp. of inlet water is too low

water pipe or tube isfrozen

increase water pressure

clean the nozzle

adjust the seating position

clean up the tube

the fillter is dirty clean the fillter

open the inlet valve

plug in socket well

press “start” button to boot the toilet

pull out the plug and send theproduct to maintenance center

check if power failure

No water out

Water not warm

Cover not warm

Smell not well

freezing water from toilet in winter.

General MeasuresNo water out cause freezing

Please follow the instructions as below to aovid it.

Keep power on

Set the water temp. and seat Please use the hot cloth cover onthe inlet valve or connectingparts until the water is unfrozen

Please use the hot cloth cover onthe inlet valve or connectingparts until the water is unfrozen

when the water is frozen.

Do not put the hot water on thetube and do not blow hot air on

May cause damage of tubeit.

Turn on the heating in housePlease follow the ways as belowto clean up the water from inlet tube if there is not heating.

a. Close the inlet valveb. Run the rear washing until there

is no water out after setting to normal level and put a hand on the seat sensor area.

temp. to high level and close thecover

Caution

Caution

Must close the inlet valve before dismantling inlet tube.Ensure correct installation of inlet tube.

May cause leakage easily

Page 14: Intelligent Toilet Manual - secure.img1-ag.wfcdn.com

Specifications

Part Spec.Rated voltage

Washing functions

DryingSeat

Deodorizeheating

Rated powerRear 200-800 mL/min

200-800 mL/min200-700 mL/min

Bidet

Outlet temp.Pressure

Time required

Heating power

Heating power

Heating power

Safety device

Safety device

Safety device

Moving washing

Massage

Nozzle positionInlet water temp.

Inlet pressure

Carton size

G.W

Type

sensitive switch, temp. fuse

sensitive switch, temp. fuse

nano precious metal oxide catalyst technology

1.5cm each for forward and backward

adjustable for forward and backwardhome temp.~40

strong and weak spaced vortex bubbles

Wind temp.

Seat temp.

Air rate

Backflow prevention

flow sensor, temp. sensor, temp. control, relay

retaining valve

250W

47W

3 levles 5 seconds (base on inlet water temp.)

home temp. / 33 / 36 / 40 (4 levles)Defaecate

Water flow

et Temp. 15 ℃±2℃, 0.2Mpa)100W (Inl

1400W (max)

AC 110V 50/60Hz

home temp. / 34 / 37 / 40 (4 levles)

home temp. / 45 / 55 / 65

1