S&C 6800 Series Automatic Switch Controls Instruction Sheet 1045-571 August 4, 2014 © S&C Electric Company Section Page Introduction Qualified Persons 2 Read this Instruction Sheet 2 Retain this Instruction Sheet 2 Proper Application 2 Safety Information Understanding Safety-Alert Messages 3 Following Safety Instructions 3 Replacement Instructions and Labels 3 Overview 4 Establishing a Serial or WiFi Connection 5 Firmware Upgrade Save Settings 9 Firmware Update 9 Firmware Reversion 12 Table of Contents IntelliLink ® Setup Software Section Page

Upload: truongnga

Post on 21-May-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

S&C 6800 Series Automatic Switch Controls

Instruction Sheet 1045-571August 4, 2014© S&C Electric Company

Section Page

IntroductionQualified Persons . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Read this Instruction Sheet . . . . . . . . . . . . . . . . . . . 2Retain this Instruction Sheet . . . . . . . . . . . . . . . . . . 2Proper Application . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Safety InformationUnderstanding Safety-Alert Messages . . . . . . . . . . . 3Following Safety Instructions . . . . . . . . . . . . . . . . . . 3Replacement Instructions and Labels . . . . . . . . . . . 3

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Establishing a Serial or WiFi Connection . . . . . . . 5

Firmware UpgradeSave Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Firmware Update . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Firmware Reversion . . . . . . . . . . . . . . . . . . . . . . . . . .12

Table of Contents

IntelliLink® Setup Software

Section Page

2 S&C Instruction Sheet 1045-571

Introduction

Qualified Persons

Read this Instruction Sheet

Retain this Instruction Sheet

Thoroughly and carefully read this instruction sheet before programming, operating, or maintaining your S&C 6800 Series Automatic Switch Control. Familiarize yourself with the safety information on page 3. The latest version of this instruction sheet is available online in PDF format at sandc.com/support/product-literature.asp

This instruction sheet is a permanent part of your S&C 6800 Series Automatic Switch Control. Designate a location where you can easily retrieve and refer to this publication.

Ç CAUTIONThe equipment in this publication must be selected for a specific application . The application must be within the ratings furnished for the selected equipment .

Proper Application

Ç WARNINGThe equipment covered by this publication must be installed, operated, and maintained by qualified persons who are knowledgeable in the installation, operation, and maintenance of overhead electric power distribution equipment along with the associated hazards .

A qualified person is one who is trained and competent in:

• The skills and techniques necessary to distinguish exposed live parts from non-live parts of electrical equipment .

• The skills and techniques necessary to determine the proper approach distances corresponding to the voltages to which the qualified person will be exposed .

• The proper use of the special precautionary techniques, personal protective equip-ment, insulating and shielding materials, and insulated tools for working on or near exposed energized parts of electrical equipment .

These instructions are intended only for such qualified persons . They are not intended to be a substitute for adequate training and experience in safety procedures for this type of equipment .

S&C Instruction Sheet 1045-571 3

Safety Information

Understanding Safety-Alert Messages

Following Safety Instructions

Replacement Instructions and Labels

There are several types of safety-alert messages which may appear throughout this instruc-tion sheet as well as on labels attached to the S&C 6800 Series Automatic Switch Control. Familiarize yourself with these types of messages and the importance of the various signal words, as explained below.

Ç DANGER“DANGER” identifies the most serious and immediate hazards which will likely result in serious personal injury or death if instructions, including recommended precautions, are not followed .

Ç WARNING“WARNING” identifies hazards or unsafe practices which can result in serious personal injury or death if instructions, including recommended precautions, are not followed .

Ç CAUTION“CAUTION” identifies hazards or unsafe practices which can result in minor personal injury or product or property damage if instructions, including recommended precau-tions, are not followed .

NOTICE“NOTICE” identifies important procedures or requirements that can result in product or property damage if instructions are not followed .

If you do not understand any portion of this instruction sheet and need assistance, contact your nearest S&C Sales Office or S&C Authorized Distributor. Their tele- phone numbers are listed on S&C’s website sandc.com/salesdirectory/default.asp. Or call S&C Headquarters at (773) 338-1000; in Canada, call S&C Electric Canada Ltd. at (416) 249-9171.

NOTICE

Read this instruction sheet thoroughly and carefully before installing or operating your S&C 6800 Series Automatic Switch Control .

If you need additional copies of this instruction sheet, contact your nearest S&C Sales Office, S&C Authorized Distributor, S&C Headquarters, or S&C Electric Canada Ltd.

It is important that any missing, damaged, or faded labels on the equipment be replaced immediately. Replacement labels are available by contacting your nearest S&C Sales Office, S&C Authorized Distributor, S&C Headquarters, or S&C Electric Canada Ltd.

4 S&C Instruction Sheet 1045-571

Overview

6800 Series Automatic Switch Controls shipping after March 31, 2013 will ship with 6800 Series Software 3.5.0 or above.

This document covers serial and WiFi connection to the 6800 Series Automatic Switch Control’s local user communication port. The software installer for 6800 Series Auto-matic Switch Controls is similar to the installers for IntelliRupter® PulseCloser, and the IntelliNode™ Interface Module. The overview section in Instruction Sheet 766-571 Soft-ware Installation will provide useful information relative to 6800 Series software installer, as will the IntelliRupter Software Installer section. Follow the procedure described in the IntelliRupter Software Installer section for 6800 Automatic Switch Control software version 3.5.0 and higher.

See the Computer Requirements section IntelliRupter Instruction Sheet 766-571 for computer requirements, and the IntelliLink® Remote License Activation section in IntelliRupter Instructions Sheet 766-571 if you are an IntelliLink Remote Setup Software user.

S&C Instruction Sheet 1045-571 5

Establishing a Serial or WiFi Connection

Figure 1. Windows 7 Start Menu.

Select Start>All Programs>S&C Electric>IntelliLink. See Figure 1.

Select Local Connection from the S&C Electric IntelliShell – Select Connection Mode dialog box. See Figure 2.

Figure 2. S&C Electric IntelliShell—Select Connection Mode dialog box.

6 S&C Instruction Sheet 1045-571

Establishing a Serial or WiFi Connection

Select Series 6800 IntellTEAM II/SG form the S&C Electric IntelliShell – Product Selection dialog and click the Serial button to make a serial connection, or WiFi to make a WiFi connection. See Figure 3.

Figure 3. S&C Electric IntelliShell—Product Selection dialog box.

If you clicked the Serial button in the S&C Electric IntelliShell – Local Communica-tion Setup dialog:

1. Select the appropriate Comm Port for your computer.

2. Make sure the Timeout(ms) is ≥ 1000.

3. Select the Baud Rate. The default baud rate for an IntelliLink connection is 9600. If you have changed the baud rate setting and don’t remember what it is, you can use the AUTO selection, and IntelliLink will try all the available baud rates to attempt to make a connection.

4. Click the IntelliLink button. See the Firmware Update section on page 9 if you want to do a firmware update. See Figure 4.

Figure 4. S&C Electric IntelliShell—Local Communication Setup dialog box.

S&C Instruction Sheet 1045-571 7

Establishing a Serial or WiFi Connection

If you Selected the WiFi button in the LinkStart Dialog:

1. Use the Prev and Next button to fine the control serial number, or enter the control serial number in the Serial Number: field.

2. Click the Connect button. See Figure 5.

Figure 5. LinkStart dialog box.

The Ilink Loader dialog box will open followed by the S&C IntelliLink Login dialog box. See Figures 6 and Figure 7 on page 8. Enter your User Name and Password, and click OK. The default entries are User Name: admin, and Password: 1135Atlantic.

If IntelliLink is unable to connect, the Ilink Loader will display Could not connect to device. See Figure 6. Check your connection and the settings above.

Figure 6. Ilink Loader dialog box.

8 S&C Instruction Sheet 1045-571

Establishing a Serial or WiFi Connection

Figure 7. S&C IntelliLink Login dialog box.

When the login has completed the main Operation screen opens. See Figure 8.

Figure 8. 6801/2/3 Operation screen.

S&C Instruction Sheet 1045-571 9

Firmware Upgrade

NOTICEUpgrading firmware can result in a loss of settings . Always save your settings and save a snapshot file before upgrading firmware .

To save your settings select File>Save Setpoints… from the main menu bar. In the Save Setpoints dialog box click the Select All button followed by the “…” browse button. See Figure 9. A file explorer will then open. Browse to the desired storage location, enter a name for the settings file and click the Save button on the browser dialog box.

Figure 9. Save Setpoints dialog box.

To save a “snapshot,” which is a copy of the control memory including logs, select File> Save Memory Snapshot.

Save Settings

Firmware Update Start IntelliLink as described above and set the Comm Port, Baud Rate, Protocol, and Timeout as indicated above for the Serial connection. See Figure 10. Then click Update Firmware.

Figure 10. S&C Electric IntelliSHELL—Local Communication Setup dialog box.

10 S&C Instruction Sheet 1045-571

Firmware Upgrade

If you selected WiFi login, after the Operation screen opens, select Tools>Firmware Update… from the main menu. See Figure 11.

Figure 11. Tools>Firmware Update... menu option.

Multiple Confirmation dialogs similar to the following may appear. See Figures 12 and 13. If they do, the recommendation is to select Yes.

Figure 12. Confirmation dialog box with Upgrade Choice.

Next a Confirmation dialog box will appear with a list of the software items to be downloaded. Select Yes to complete the upgrade, or No to exit.

Figure 13. Confirmation dialog box with selected upgrade confirmation.

S&C Instruction Sheet 1045-571 11

Firmware Upgrade

Next the Firmware Update dialog box will open to show the upgrade progress. After the update has completed, and the Script completed successfully message appears, click the Close button to finish. See Figure 14.

Figure 14. Firmware Upgrade dialog box.

12 S&C Instruction Sheet 1045-571

Firmware Reversion

In some cases it may be necessary to revert to a previous version of 6800 Automatic Switch Control Firmware. Follow this procedure to change the firmware version.

1. Choose the required firmware revision, and obtain the software installer from the S&C Automation Customer Support Portal, if necessary. See Instruction Sheet 766-571 for more information about the Portal.

2. Click Start and select Control Panel, see Figure 15.

Figure 15. Control Panel selection on the Windows 7 Start Menu.

S&C Instruction Sheet 1045-571 13

Firmware Reversion

3. From the Control Panel select Programs and Features, or for Windows XP select Add/Remove Programs, see Figure 16.

4. Remove all software revisions that are higher than the target revision. If there are multiple revisions work from the highest first to the lowest last.

5. If you already have IntelliLink6 installed, remove it.

6. Open Windows File Explorer and navigate to: C:\Program Files (x86)\S&C Electric\Products\SG680xxx\Firmware\Upgrades (where: SG680xxx = the product to upgrade such as SG6801).

7. Delete any folders that have a version number higher than the target revision. See Figure 17.

Figure 16. Windows 7 Control Panel.

Figure 17. Indicated Firmware Upgrades in Windows File Explorer.

14 S&C Instruction Sheet 1045-571

Firmware Reversion

8. Run the installer for the target version. If the target revision is already installed select the repair option, when it is presented by the installer.

9. Start IntelliLink (see Figure 1), and set the Comm Port, Baud Rate, Protocol, and Timeout (see Figure 4). Then click Update Firmware.

10. The Log On dialog opens, see Figure 18. Logon with your User Name and Password, or use the default: User Name: admin and Password: 1135Atlantic if you have not changed them.

11. After you logon click the Start Download button.

Figure 18. S&C Download Utility.

S&C Instruction Sheet 1045-571 15

Firmware Reversion

12. Depending on the target version selected, the following S&C Control Software Loader dialog may appear, see Figure 19. If it does click No.

13. Because the firmware in the control has higher versions of the software components, an S&C Control Software Loader dialog message, similar to Figure 20, will appear. If it asks to Skip this download? click the No button.

Figure 19. S&C Control Software Loader dialog—Exit?

Figure 20. S&C Control software Loader dialog—Skip this download?

16 S&C Instruction Sheet 1045-571

14. When the download has completed, the S&C Control Software Loader dialog will open with the message Task completed. Exit? See Figure 21. Click the Yes button.

Figure 21. S&C Control Software Loader dialog—Exit?

Prin

ted

in U

.S .A

.

Firmware Reversion