Page 1: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Interior Sign Standards Manual Selection & Specification Guide

Updated jUly 2012

DRAFT

FEDERIT
Text Box
Page 2: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Table of Contents ..................................................................................................... 1

Introduction ............................................................................................................. 1

section 1

IntroductionAbbreviated House Style ........................................................................................... 1

Interior Sign Program ................................................................................................ 1

section 2

Sign Selection ChartsBy Function

Directionals ............................................................................................................. 1

Public Convenience Identification ............................................................................... 1

Identification Signs ................................................................................................... 1

Regulatory & Informational Signs ............................................................................... 1

Donor Signage ......................................................................................................... 1

By Application

Desk Signs .............................................................................................................. 1

Overhead Signs ........................................................................................................ 1

Projected Mount Signs .............................................................................................. 1

Vinyl ....................................................................................................................... 1

Wall Panels ............................................................................................................. 1

ADA Wall Plaques & Window Signs ............................................................................ 1

Window Signs.......................................................................................................... 1

section 3

Sign Drawing PagesBy Sign Type ........................................................................................................... 1

Table of Contents

2 Page TitleCleveland Clinic Interior Sign Standards Manual

Page 3: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

section 4

ElevationsElevation 1 : Large Wall Plaques ............................................................................... 1

Elevation 2 : Small Wall Plaques ............................................................................... 1

Elevation 3 : Overhead Signs .................................................................................... 1

Elevation 4 : Projected Mount Signs .......................................................................... 1

Elevation 5 : Desk Signs .......................................................................................... 1

Elevation 6 : Room Identification ............................................................................... 1

Elevation 7 : Typical Elevator Signage ........................................................................ 1

Elevation 8 : Typical Entry Signage ............................................................................ 1

Elevation 9 : Typical Stairwell Signage ....................................................................... 1

Elevation 10 : Typical Donor Signage ......................................................................... 1

section 5

AppendicesAppendix A : Sign Photos .......................................................................................... 1

Table of Contents

3 Page TitleCleveland Clinic Interior Sign Standards Manual

Page 4: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Introduction

sign program promise

For most, navigating an unfamiliar medical facility when faced with an illness or emergency situation can be a stressful, if not fear-inducing, scenario. Through its brand promise at left, Cleveland Clinic commits to "stand as the polar opposite of fear" (House Style Guidelines, 07).

As a direct extension of its brand, the Cleveland Clinic Interior Sign program is designed to "project confidence and justify the confidence of our patients and their families" by providing clear, consistent and universally-accessible wayfinding information throughout all system facilities.

The Cleveland Clinic Interior Sign program:

• Sets up a clear organizational system of wayfinding information, whereby visitors to system facilities have consistent expectations for these tools;

• Integrates wayfinding information within the hospital environment so that signage is both functional and minimal;

• Meets guidelines for accessibility and safety by providing information for all visitors regardless of ability;

• Provides a quality sign system that may last over time through the use of changeable messages; and

• Supports and communicates the CCF brand promise through the use of consistent brand elements, well-crafted materials and consistent messaging.

sign standards manUal

The purpose of this Manual is to define the system, specifications, and construction details for each sign type of the program. This document serves as a resource for both internal personnel and outside contractors to aid in the selection, fabrication and implementation of interior signs. The details outlined throughout this guide should be followed carefully to maintain absolute consistency in construction, materials, graphic language and messaging.

This guide is divided into five sections:

section 1: introduction Provides an overview of the Cleveland Clinic House Style, defining its brand elements including typography, colors, and signature. Defines the philosophies, nomenclature and graphic elements of the Interior Sign program. Includes contact information for all signage requests.

section 2: sign selection charts Presents all sign types in visual hierarchies to guide the selection of signs appropriate to the information communicated, quantity of messages and architectural contexts. Provides two categories of selection: by Function and by Application.

section 3: sign drawing pages Individual pages detailing each sign type or element, including design intent, colors, text, dimensions, materials, construction and mounting specifications.

section 4: elevations Illustrates typical elevations per architectural context. Elevations are cross-referenced on Sign Drawing Pages; multiple sign types may point to common elevations.

section 5: appendices Appendix A includes photographic examples of specific sign applications, cross-referenced from Section 2 Charts.

Complete Confidence

At a time of stress and uncertainty, patients and their families can take comfort and find peace of mind that their hopes for the best outcome and best care will be realized at Cleveland Clinic.

4 Page TitleCleveland Clinic Interior Sign Standards Manual

Page 5: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

section 1

Introduction

Abbreviated House Style

Signatures......................................... 1

Typography ....................................... 1

Colors............................................... 1

Interior Sign Program

Requests & Contacts .......................... 1

Arrows & Symbols .............................. 1

Nomenclature ................................... 1

5Cleveland Clinic Interior Sign Standards Manual

Page 6: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Abbreviated House StyleSignatures

signatUre

The Cleveland Clinic signature consists of the symbol and the proprietary wordmark "Cleveland Clinic."

the symbol The Cleveland Clinic brand identity was designed to reflect our heritage as a medical pioneer and our position today as a premier healthcare institution.

the shape Four cornerstones in the symbol represent the facets of our mission: patient care (clinical and hospital), education and research. They honor our four founders. Finally, the four corners symbolize our fundamental values: quality, innovation, teamwork and service. The center of the symbol represents a window to the needs of our patients and stands for our focused commitment to putting "Patients First" in all we do.

the colors The colors of the Cleveland Clinic symbol are inspired by our heritage. The green is based on the Cleveland Clinic Foundation signature and is traditionally associated with medical science. The blue is the color of the Cleveland Clinic Health System signature and suggests limitless possibility.

signatUre

Children’s Hospital is a sub-brand of the Cleveland Clinic. Sub-brands are linked to the Masterbrand through color and typography, and use the Cleveland Clinic name as an endorsement. These elements are arranged in a fixed relationship that mirrors the basic visual structure of the Masterbrand as closely as possible.

Symbol Wordmark

Excerpts from the Cleveland Clinic House Style Guidelines, 06/12/07

6 Page TitleCleveland Clinic Interior Sign Standards Manual

FEDERIT
Stamp
Page 7: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Abbreviated House StyleTypography

primary typeface

The primary Cleveland Clinic typeface, News Gothic BT, is a sans serif typeface that is highly legible when used in headlines or body copy. The weight "Demi" is used on all interior signage messaging with no substitutions permitted. Sign fabricators are to purchase the font for production; this font is available for purchase at fontshop.com.

demi

aBcdefgHijKlmnopQrstUVWXyZabcdefghijklmnopqrstuvwxyz0123456789

Excerpts from the Cleveland Clinic House Style Guidelines, 06/12/07

7 Page TitleCleveland Clinic Interior Sign Standards Manual

Page 8: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Abbreviated House StyleColors

primary color palette

Below are the colors that make up the brand’s primary color palette. These colors are expressed throughout the sign program via printed colors (values specified below) and selected material matches (see individual sign specifications).

Cleveland Clinic White Cleveland Clinic Black

Cleveland Clinic Blue Cleveland Clinic Green

Pantone Black 7

CMYK 0/0/15/82

RGB 83/83/74

Pantone 3005

CMYK 100/28/0/0

RGB 0/122/201

Web 0/153/204

Pantone 348

CMYK 100/4/87/18

RGB 0/133/66

Web 0/153/51

Excerpts from the Cleveland Clinic House Style Guidelines, 06/12/07

8 Page TitleCleveland Clinic Interior Sign Standards Manual

Page 9: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Interior Sign ProgramRequests & Contacts

signage reQUests

Sign types J.1 and U.1 may be requested via the CCF Intranet at: //url here// For all other signage requests or questions about interior signage, please contact:

tom federico Signage Department Manager Facilities Engineering

[email protected]

cleveland clinic 9500 Euclid Ave. Cleveland, OH 44195 (216) 444-243

marKing / HoUse style reQUests

For additonal information regarding the use of Cleveland Clinic brand elements, or to request a full copy of the Cleveland Clinic House Style Guidelines, please contact:

contact name Title Department Name (Marketing?)

cleveland clinic (address 1) (address 2) (phone number)

signage & Wayfinding consUltants

This manual was prepared by Studio Graphique, Inc. under the direction of the Cleveland Clinic Signage Executive Committee:

Executive Committee Member 1

Executive Committee Member 2

Executive Committee Member 3

Executive Committee Member 4

9 Page TitleCleveland Clinic Interior Sign Standards Manual

tel 216-921-0750 web designwithdirection.com

Page 10: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Interior Sign ProgramArrows & Symbols

arroWs

left arrow

women women / accessible

stairs stairwell evacuation in case of fire fire extinguishertelephone

no smokingno cellphone use

biohazardradiation no entry defibrillatorcrash cart

no food & drinkcellphonediningwaiting

restroom

elevator

men men / accessible accessible

right arrowup arrow down arrow up right arrow up left arrow

pUBlic conVeniences

life safety

10 Page TitleCleveland Clinic Interior Sign Standards Manual

Page 11: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Interior Sign ProgramMaterials & Finishes Palette

primary color palette

The following is a comprehensive list of materials and finishes used in the fabrication of the interior sign types detailed in Section 3.

Plaques, etc.

9MM Grey Komatex (rigid PVC)

Matte Clear Acrylite FF P99

Gloss Clear Acrylic

.037 photo polymer Overlay (ADA)

Filler - Tempered Hardboard

MDF

Wood

Kopine (typo - korpine)

.040 Lexan (w/#56 Hole drilled through and dimpled) - for pin-mounting

Red RH #2157 Acrylic

P68 Matte Acrylic

colors

Matthews Paint Brushed Aluminum #41-342

Metallic Silver (paint) M45

osHa colors

Yellow S12

Purple S54

Red S20

Blue S52

Green S51

coPy

Screened Black 9700

Screened Black Epoxy

Red 9700 Flame

Red Epoxy

Raised copy, symbols (screened black?)

cHemetal laminate

CM909 Satin Aluminum (Miller Pavilion & Glickman Institute Only)

CM902 Horizontal Brushed

Vinyls/Films

Frosted Crystal Pressure-Sensitive Vinyl #7725-324

Matte Black PSV (3M series 220 P20871C)

Matte White PSV (3M series 220-20)

Chrome Scratch Vinyl (PSV 9250) (Avery A1840-S)

Silver Metallic Vinyl PSV 9275 (Avery A5701)

Metallic Silver PSV-PSV 9232

4 mil clear Océ Film

.010 Clear Gerber Lexedge

Olympic Blue Gerber GCS-57

Kelly Green Gerber GCS-46

Transparent Deep Sky Blue Gerber Vinyl #P51467A

Transparent Bright Green Vinyl #P35341A

Red (3M #220-13)

Etched (Dusted crystal #7725-314)

(matte grey window backer?)

screws/inserts

Misc. Finishing notes

Belted Returns

mounting

Roll Pin

Clear Bent Acrylic (sign base)

Natural Satin Anodized (Aluminum Bracket)

11 Page TitleCleveland Clinic Interior Sign Standards Manual

Page 12: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Interior Sign ProgramNomenclature

building naming

TBD

desk / department numbering

TBD

room numbering

TBD

donor names

TBD

12 Page TitleCleveland Clinic Interior Sign Standards Manual

Page 13: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

section 2

Sign Selection Charts

By Function

Directionals ....................................... 1

Public Convenience Identification ......... 1

Identification Signs ............................. 1

Regulatory & Informational Signs ......... 1

Donor Signage ................................... 1

By Application

Desk Signs ........................................ 1

Overhead Signs ................................. 1

Projected Mount Signs ........................ 1

Vinyl ................................................ 1

Wall Panels ....................................... 1

ADA Wall Plaques & Window Signs ...... 1

Window Signs ................................... 1

13Cleveland Clinic Interior Sign Standards Manual

Page 14: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Selection Charts (By Function)

Directionals

tHUmBnail sign code sign name application siZe (in.) approVed Uses information commUni-cated

draWing page

D1.3020 Directional Plaque Wall Panel 20 x 30 Current Building, Current Level

Directional Messages(up to 8 destinations)

D1.3620 Directional Plaque Wall Panel 20 x 36 Current Building, Current Level

Directional Messages (up to 14 destinations)

OH.1414 Overhead Sign Overhead 14 x 14 Destination Name

Directional Messages (up to 1 destination)

14 Selection ChartsCleveland Clinic Interior Sign Standards Manual

Page 15: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Selection Charts (By Function)

Public Convenience Identification

tHUmBnail sign code sign name application siZe (in.) approVed Uses information commUni-cated

draWing page

E.1 ADA Acrylic Symbol Plaque Wall Plaque (ADA)

9 x 9 Symbol, Raised Public Convenience Name, Braille

E.2 9x9 Projected Mount Projected Mount 9 x 9 Symbol, Public Convenience Name

F.1 Stair Plaque Wall Plaque (ADA)

9 x 9 Identifies Stair Name (letter designation) outside of fire stair

Stair Identifier, "Fire Door Keep Closed", "In the event of a fire doors unlock automatically", Stair Symbol, Braille

G.1 ADA Acrylic Stairwell Plaque Wall Plaque (ADA)

9 x 9 Identifies Level (number) within fire stair and Stair Name (letter designation)

Current Level; Levels Accessed & Egress Information; Braille

G.2 Stairwell Evacuation Directional Plaque

Wall Plaque (ADA)

9 x 4.5 Modular Plaque to be used only in conjunction with G.2

Provides egress directional information within stairwell

15 Selection ChartsCleveland Clinic Interior Sign Standards Manual

Page 16: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Selection Charts (By Function)

Identification Signs

tHUmBnail sign code sign name application siZe (in.) approVed Uses information commUni-cated

draWing page

D2.1548 Area Destination Plaque Wall Panel 48 x 15 Desk Name, Department Name

J.1 ADA Acrylic Window Plaque Window (ADA) 6 x 6 ADA : Permanent Room Number & Braille

Changeable Message may include: Additional (non-ADA) Room ID or Information, Regulatory Messages, Office Occupant Name

M.1 PSV Lettering Vinyl (varies) Donor Name, Destination Name

M.2 Entrance Door PSV Vinyl (varies) Cleveland Clinic Logo, Building / Facility Name & Address, May include “Urgent Care” message

OH.1414 Overhead Sign Overhead 14 x 14 Destination Name, Directional Messages (up to 1 destination)

OH.1424 Overhead Sign Overhead 14 x 24 Desk / Department Name

OH.66 Overhead Sign Overhead 6 x 6 Destination Name, Room Number

P.1 9 x 9 ADA Acrylic Window Plaque

Window (ADA) 9 x 9 ADA : Permanent Room Number & Braille

Changeable Message may include: Additional (non-ADA) Room ID or Information

16 Selection ChartsCleveland Clinic Interior Sign Standards Manual

Page 17: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Selection Charts (By Function)

Identification Signs (Cont'd)

sign code sign name application siZe (in.) approVed Uses information commUni-cated

draWing page

RV Vinyl Door Tag Vinyl 3.5 x 1 Room Number

T.1 Acrylic Slide Plaque Window 6 x 3 Modular Plaque to be used with 6 x 6 Plaques

Provides Occupied/Vacant Information such as:

In Use, In Conference, Case In Progress / Do Not Enter, X-Ray In Use, Meeting In Progress

U.2 Bent Acrylic Insert Holder Desk Sign 6 x 3.5 Desk/Workstation Number, Personnel Name(s) and Title(s)

U.3 Bent Acrylic Insert Holder Desk Sign 8 x 3 Desk/Workstation Number, Personnel Name(s) and Title(s)

WH.1414 Wall Hung Sign Mounting Detail

Projected Mount 14 x 14 Destination Name, Public Convenience Symbol/ID

H Dimensional Letters Dimensional Letters

(varies) Donor Name, Destination Name

17 Selection ChartsCleveland Clinic Interior Sign Standards Manual

Page 18: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Selection Charts (By Function)

Regulatory & Informational Signs

sign code sign name application siZe (in.) approVed Uses information commUnicated draWing page

C.AL In Case of Fire Plaque Wall Plaque 6 x 6 In Case of Fire Use Stairs, Do Not Use Elevators, In Case Symbol

C.SS In Case of Fire Plaque Wall Plaque 5 x 5 In Case of Fire Use Stairs, Do Not Use Elevators, In Case Symbol

M.3 Call Lights PSV Vinyl (varies) Call Light ID Numbers

N.1 Fire Extinguisher PSV Vinyl (varies) On Cabinet Face: Fire Extinguisher Symbol

N.2 Fire Extinguisher PSV Vinyl (varies) On Cabinet Side: Fire Extinguisher, Symbol

OH.1048 Overhead Sign Overhead 10 x 48 Do Not Enter Authorized Personnel Only (Do Not Enter Symbols)

Q.10 6 x 6 Acrylic Plaque Wall Plaque 6 x 6 Sterile Attire Required Proper Attire Required

Q.11 6 x 6 Acrylic Plaque Wall Plaque 6 x 6 (Do Not Enter Symbol) Authorized Personnel Only, No Admittance Authorized Personnel Only Authorized Access ONLY

Q.12 6 x 6 Acrylic Plaque Wall Plaque 6 x 6 In case of fire, doors will automatically unlock.

Q.13 6 x 6 Acrylic Plaque Wall Plaque 6 x 6 (Do Not Enter Symbol) Emergency EXIT ONLY Door Sounds Alarm

18 Selection ChartsCleveland Clinic Interior Sign Standards Manual

Page 19: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

sign code sign name application siZe (in.) approVed Uses information commUnicated draWing page

Q.14 6 x 6 Projected Mount Projected Mount 6 x 6 (Defib Symbol) Defib (Fire Extinguisher Symbol) Fire Extinguisher (Crash Cart Symbol) Crash Cart

Q.15 6 x 6 Acrylic Plaque Wall Plaque 6 x 6 CAUTION (Radioactive Symbol) Radioactive Material

Q.15a 3 x 3 Acrylic Plaque Wall Plaque 3 x 3 CAUTION (Radioactive Symbol) Radioactive Material

Q.16 6 x 6 Acrylic Plaque Wall Plaque 6 x 6 BIOHAZARDOUS MATERIAL (Biohazard Symbol) Authorized Personnel Only

Q.17 6 x 6 Acrylic Plaque Wall Plaque 6 x 6 SAFETY Eye Wash Station

Q.18 6 x 6 Acrylic Plaque Wall Plaque 6 x 6 (No Food/Drink Symbol) Food and Beverages Not Permitted

Q.19 6 x 6 Acrylic Plaque Wall Plaque 6 x 6 (Do Not Enter Symbol) Restricted Area

Q.2 6 x 6 Acrylic Plaque Wall Plaque 6 x 6 PLEASE Unlock Both Doors When Leaving LOCK Both Doors For Privacy (HC Symbol) DISABLED RESTROOM Located on First Floor/Lobby

Q.22 9 x 9 Acrylic Plaque Wall Plaque 9 x 9 Roof Access

Q.23 9 x 9 Acrylic Plaque Wall Plaque 9 x 9 (No Food/Drink Symbol) Food and Beverages Not Permitted

Regulatory & Informational Signs (Cont'd)

Selection Charts (By Function)

19 Selection ChartsCleveland Clinic Interior Sign Standards Manual

Page 20: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Regulatory & Informational Signs (Cont'd)

Selection Charts (By Function)

sign code sign name application siZe (in.) approVed Uses information commUnicated draWing page

Q.24 6 x 6 Acrylic Plaque Wall Plaque 6 x 6 2 Visitors Only 1 Visitor Only Per Patient

Q.25 9 x 9 Acrylic Plaque Wall Plaque 9 x 9 For The Privacy And Comfort Of All Our Patients, 2 Visitors Per Patient For The Privacy And Comfort Of All Our Patients, 1 Visitor Per Patient

Q.3 13 x 13 Acrylic Plaque Desk Sign 13 x 13 (Waiting Symbol) If you have been waiting longer than (15/20/30) minutes, from your scheduled appointment time, please notify the receptionist.

Q.8 6 x 6 Acrylic Plaque Wall Plaque 6 x 6 If you are pregnant, notify technologist before radiology exam.

S.1 Acrylic Fire Evacuation Plaque (who provides the evac map?)

Window 13 x 13 Fire Evacuation (Evacuation Map Insert)

V.4 9 x 9 Acrylic Plaque Wall Plaque 9 x 9 Cellular Phone Use Prohibited (No Cell Symbol)

V.6 9 x 9 Acrylic Plaque Wall Plaque 9 x 9 Cellular Phone Safe Zone Cellular Phone Usage Permitted Only in Safe Zone Areas (Cell Symbol)

20 Selection ChartsCleveland Clinic Interior Sign Standards Manual

Page 21: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Selection Charts (By Function)

Donor Signage

sign code sign name application siZe (in.) approVed Uses information commUnicated draWing page

H Dimensional Letters Dimensional Letters

(varies) Donor Name Destination Name

21 Selection ChartsCleveland Clinic Interior Sign Standards Manual

Page 22: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Selection Charts (By Application)

Desk Signssign code sign name application siZe (in.) approVed Uses information commUnicated draWing page

Q.3 13 x 13 Acrylic Plaque Regulatory/Informational

13 x 13 (Waiting Symbol) If you have been waiting longer than (15/20/30) minutes, from your scheduled appointment time, please notify the receptionist.

U.2 Bent Acrylic Insert Holder Identification 6 x 3.5 Desk/Workstation Number Personnel Name(s) and Title(s)

U.3 Bent Acrylic Insert Holder Identification 8 x 3 Desk/Workstation Number Personnel Name(s) and Title(s)

22 Selection ChartsCleveland Clinic Interior Sign Standards Manual

Page 23: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Selection Charts (By Application)

Overhead Signssign code sign name application siZe (in.) approVed Uses information commUnicated draWing page

OH.1048 Overhead Sign Regulatory/Informational

10 x 48 Do Not Enter Authorized Personnel Only (Do Not Enter Symbols)

OH.1414 Overhead Sign Directional 14 x 14 Destination Name Directional Messages (up to 1 destination)

OH.1414 Overhead Sign Identification 14 x 14 Destination Name Directional Messages (up to 1 destination)

OH.1424 Overhead Sign Identification 14 x 24 Desk / Department Name

OH.66 Overhead Sign Identification 6 x 6 Destination Name Room Number

23 Selection ChartsCleveland Clinic Interior Sign Standards Manual

Page 24: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Selection Charts (By Application)

Projected Mount Signssign code sign name application siZe (in.) approVed Uses information commUnicated draWing page

E.2 9x9 Projected Mount Public Convenience ID

9 x 9 Telephones (Telephone Symbol) Restroom (Women, Men Symbols)

Q.14 6 x 6 Projected Mount Regulatory/Informational

6 x 6 (Defib Symbol) Defib (Fire Extinguisher Symbol) Fire Extinguisher (Crash Cart Symbol) Crash Cart

WH.1414 Wall Hung Sign Mounting Detail

Identification 14 x 14 Destination Name Public Convenience Symbol/ID

24 Selection ChartsCleveland Clinic Interior Sign Standards Manual

Page 25: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Selection Charts (By Application)

Vinylsign code sign name application siZe (in.) approVed Uses information commUnicated draWing page

M.1 PSV Lettering Identification (varies) Donor Name Destination Name

M.2 Entrance Door PSV Identification (varies) Cleveland Clinic Logo Building / Facility Name & Address May include “Urgent Care” message

M.3 Call Lights PSV Regulatory/Informational

(varies) Call Light ID Numbers

N.1 Fire Extinguisher PSV Regulatory/Informational

(varies) On Cabinet Face: Fire Extinguisher Symbol

N.2 Fire Extinguisher PSV Regulatory/Informational

(varies) On Cabinet Side: Fire Extinguisher Fire Extinguisher Symbol

RV Vinyl Door Tag Identification 3.5 x 1 Room Number

25 Selection ChartsCleveland Clinic Interior Sign Standards Manual

Page 26: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Selection Charts (By Application)

Wall Panelssign code sign name application siZe (in.) approVed Uses information commUnicated draWing page

D1.3020 Directional Plaque Directional 20 x 30 Current Building Current Level Directional Messages (up to 8 destinations)

D1.3620 Directional Plaque Directional 20 x 36 Current Building Current Level Directional Messages (up to 14 destinations)

D2.1548 Area Destination Plaque Identification 48 x 15 Desk Name Department Name

26 Selection ChartsCleveland Clinic Interior Sign Standards Manual

Page 27: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Selection Charts (By Application)

ADA Wall Plaques & Window Signssign code sign name fUnction siZe (in.) approVed Uses information commUnicated draWing page

E.1 ADA Acrylic Symbol Plaque Public Convenience ID

9 x 9 Symbol, Raised Public Convenience Name, Braille

F.1 Stair Plaque Public Convenience ID

9 x 9 Identifies Stair Name (letter designation) outside of fire stair Fire Door Keep Closed In the event of a fire doors unlock automatically (Stair Symbol) Braille

G.1 ADA Acrylic Stairwell Plaque Public Convenience ID

9 x 9 Identifies Level (number) within fire stair and Stair Name (letter designation) Provides level access & egress information Braille

G.2 Stairwell Evacuation Directional Plaque

Public Convenience ID

9 x 4.5 Modular Plaque to be used with G.2 Provides egress directional information within stairwell

J.1 ADA Acrylic Window Plaque Identification 6 x 6 ADA : Permanent Room Number & Braille Changeable Message may include: Additional (non-ADA) Room ID or Information Regulatory Messages Office Occupant Name

P.1 9 x 9 ADA Acrylic Window Plaque

Identification 9 x 9 ADA : Permanent Room Number & Braille Changeable Message may include: Additional (non-ADA) Room ID or Information

27 Selection ChartsCleveland Clinic Interior Sign Standards Manual

Page 28: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Selection Charts (By Application)

Window Signssign code sign name fUnction siZe (in.) approVed Uses information commUnicated draWing page

L1.1414 Large Acrylic Window Plaque Any (Window) 14 x 14 Changeable Messages may include: Directional Messages (up to 3 destinations)

L1.1814 Large Acrylic Window Plaque Any (Window) 14 x 18 Changeable Messages may include: Desk/Departmental ID & Directory Listing

L1.3015 Large Acrylic Window Plaque Any (Window) 15 x 30 Welcome to & Cleveland Clinic Logo Provides directory listing of destinations on each level accessed from elevators Typically found at elevators

L1.66 Acrylic Window Plaque Any (Window) 6 x 6 Changeable Messages may include: Non-ADA Room ID or Information Regulatory/Informational Messages Directional Messages (up to 3 destinations)

L1.99 Acrylic Window Plaque Any (Window) 9 x 9 Changeable Messages may include: Non-ADA Room ID or Information Regulatory/Informational Messages Directional Messages (up to 5 destinations)

S.1 Acrylic Fire Evacuation Plaque (who provides the evac map?)

Regulatory/Informational

13 x 13 Fire Evacuation (Evacuation Map Insert)

28 Selection ChartsCleveland Clinic Interior Sign Standards Manual

Page 29: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

T.1 Acrylic Slide Plaque Identification 6 x 3 Modular Plaque to be used with 6 x 6 Room IDs Provides Occupied/Vacant Information: In Use In Conference Case In Progress / Do Not Enter X-Ray In Use Meeting In Progress

X Informational Window Plaque Any (Window) 9 x 12 Changeable Messages

X.1 Informational Window Plaque Any (Window) 12 x 9 Changeable Messages

X.66 Informational Window Plaque Any (Window) 6 x 6 Changeable Messages

X.99 Informational Window Plaque Any (Window) 9 x 9 Changeable Messages

XB.99 Informational Window Plaque w/Backer

Any (Window) 9 x 9 Changeable Messages

J.1 ADA Acrylic Window Plaque Identification 6 x 6 ADA : Permanent Room Number & Braille Changeable Message may include: Additional (non-ADA) Room ID or Information Regulatory Messages Office Occupant Name

P.1 9 x 9 ADA Acrylic Window Plaque

Identification 9 x 9 ADA : Permanent Room Number & Braille Changeable Message may include: Additional (non-ADA) Room ID or Information

Window Signs (Cont'd)sign code sign name fUnction siZe (in.) approVed Uses information commUnicated draWing page

Selection Charts (By Application)

29 Selection ChartsCleveland Clinic Interior Sign Standards Manual

Page 30: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

section 3

Sign Drawing Pages

(List All) ............................................... 1

30Cleveland Clinic Interior Sign Standards Manual

Page 31: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

31 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

C.AL In Case of Fire Plaque

scale: 1/2" = 1"

A Plaque1/4" Thick ??? with applied CM902 Satin Horizontal Brushed Aluminum laminate; C-13 Gloss Clear Coat; 45° Half Polished Bevel

B Copy7/16" News Gothic BT Demi; U/L; Screened Black 9724

C Symbol1-7/8"; Surface Screened Black 9724 w/ S20 Red 9700 Flame

D Ruleline1/16" x 4-1/8"; Surface Screened Black 9724

E Mount(1) Roll Pin (Center/Center) and Silicone

C.AL

In Case of FireUse StairsDo Not UseElevators

Side View

6"

6"

15/16"

3/4"

1/4"

5/8"

11/16"

2 1/4"

A

B

C

D

E

1/4"

Page 32: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

C.SS

C.SS In Case of Fire Plaque

32 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

SpecificationsA Plaque

1/8" Thick ??? with applied CMXXX Vertical Brushed Stainless Steel laminate; Belted Returns

B Copy3/8" News Gothic BT Demi; U/L; Screened Black Epoxy

C Symbol1-9/16"; Surface Screened Black Epoxy w/ S20 Red Epoxy Flame

D Rule Line1/16" x 3-1/2"; Surface Screened Black Epoxy

E MountVHB Tape and Silicone

scale: 1/2" = 1"

In Case of FireUse StairsDo Not UseElevators

Sign Back

5"

5"

3/4"

11/16"

1/4"

1/2"

11/16"

1 7/8"

A

B

C

D

E

Page 33: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

D1.3020

D1.3020 Directional Plaque

Sign Elevation Lens

Miller PavilionFloor 1

CT/MRI Sub WaitingChest X-Ray Changing Rooms 1-3

EMERGENCYEcho Rooms 1-18

20"

30"

A

B

C

D

19 3/8"

29 3/8"

Holes 13 3/4"

on center

Holes 13 3/4"

on center

17 3/8" on center

1/8"

2"

33 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

SpecificationsA Plaque

9mm Thick Grey Komatex & metal laminate (*See Note); 45° half bevel (beveled edges with no painting, only block sanded using 220-grit wet/dry)

B Lens1/8" thick Acrylite matte clear FF P99 Acrylic w/ polished returns & (6) holes drilled through; See page 22 for Assembly Detail

C Insert & CopySee Page 19

D Mount(1) Roll Pin (centered and down 2” from top) and silicone

* NoteSatin Aluminum CM909 is used for Miller Pavilion & Glickman Tower only. Horizontal Brushed CM902 is used for the rest of the hospital and satellite locations.

scale: 1-1/2" = 1'-0"

Page 34: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

34 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

SpecificationsA Insert

4 mil Clear Océ Film w/ (6) holes drilled through & Drytac lnterlam Pro Lustre 3 mil laminate on top

B Copy1" High, News Gothic BT Demi; Printed Black

C Rule Line3/16” x 16-7/8”, Printed Black

D Arrow1-1/8" x 1-3/8", Printed Black

E Emergency1” copy reversed out of printed red rectangle

NOTE: “Emergency” message always appears first within directional grouping

Miller PavilionFloor 1

Avon AmbulatorySurgery Center

Floor 1

CT/MRI Sub WaitingChest X-Ray Changing Rooms 1-3

Printed Insert

Alt Header : (3) Lines Copy

EMERGENCYEcho Rooms 1-18

1 3/4"

1 3/4"

2 3/8"

2 1/8" Typ. between arrow & message

Typ. between bottom ofheader & arrow

Typ. between lines of same message

Typ. between messages

Typ. between message & rule 1 3/8" 29 3/8"

19 3/8"

C

B

A

D

E

Holes 13 3/4"

on center

Holes 13 3/4"

on center

17 3/8" on center

4 1/2" black header

6"

1"

1 7/8"

2"

1 3/8"

2 3/8"

5/8"

2" x 16-7/8” Rectangle

1 1/2"

1 1/4"

1 3/4"

1 3/4"

1 3/4"

D1.3020

D1.3020 Directional Plaque

scale: 1-1/2" = 1'-0"

Page 35: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

D1.3620

A Plaque9mm Thick Grey Komatex & metal laminate (*See Note); 45° Half Bevel (beveled edges with no painting, only block sanded using 220-grit wet/dry)

B Lens1/8” thick Acrylite matte clear FF P99 Acrylic w/ polished returns & (6) holes drilled through; See page 22 for Assembly Detail

C Insert & CopySee Page 21

D Mount(1) Roll Pin (centered and down 2” from top) and silicone

* NoteSatin Aluminum CM909 is used for Miller Pavilion & Glickman Tower only. Horizontal Brushed CM902 is used for the rest of the hospital and satellite locations.

Sign Drawings

D1.3620

Directional Plaque

Sign Elevation Lens

Miller PavilionFloor 1

CT/MRI Sub WaitingChest X-Ray Changing Rooms 1-3

EMERGENCYEcho Rooms 1-18Exam Rooms 1-9Desk J1-5J East Elevator e Service / Patient

Holes16-11/16"

on center

Holes16-11/16"

on center

Holes 17-3/8" on center

C

DA

B

1/8"

20"

36"

35 3/8"

19-3/8"

2"

35Cleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

scale: 1-1/2" = 1'-0"

Page 36: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

D1.3620

A Insert4 mil clear Océ Film w/ (6) holes drilled through & Drytac lnterlam Pro Lustre 3 mil laminate on top

B Copy1” High, News Gothic BT Demi; Printed Black

C Arrow1-1/8" x 1-3/8", Printed Black

D Rule Line(s)3/16" x 16-7/8" Printed Black

E Emergency1” copy reversed out of printed red rectangle

NOTE: “Emergency” message always appears first within directional grouping

F Symbol1" Symbol, align bottom with baseline of copy

D1.3620

Avon AmbulatorySurgery Center

Floor 1

Miller PavilionFloor 1

CT/MRI Sub WaitingChest X-Ray Changing Rooms 1-3

EMERGENCYEcho Rooms 1-18Exam Rooms 1-9Desk J1-5J East Elevator e Service / Patient

35 11/32"

1 3/4"

1 3/4"

2 3/8"

2 1/8"

Holes 17-3/8" on center

19-11/32"

Holes16-11/16"

on center

Holes16-11/16"

on center

Typ. between arrow & message

Typ. between bottom of header & arrow

Typ. between linesof same message

Typ. between messages

Typ. betweenmessage & rule

1 3/8"

A

B

C

D

F

E

Printed Insert

Alt Header : (3) Lines Copy

4 1/2" header

3/4"

2" x 16-7/8" rectangle 1 1/2"

1 7/8"

1 3/4"

1 3/4"

1 3/4"

6"

2"

1 3/8"

2 3/8"

1 1/2"

3/8" sq.

Directional Plaque

36 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

scale: 1-1/2" = 1'-0"

Page 37: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

37 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

Exploded View

PLAQUEINSERTPLAQUE COVERSCREW

1"

1"

15/64" hole drilledthrough plaque cover

A

B

A ScrewsV688 McMaster-Carr #93615A370 Low Head Socket Cap Screw, 10-32 x 3/8" long, 15/64" hole drilled through plaque cover

B InsertsV688 McMaster-Carr #95110A115 18-8 S.S. knurled press insert w/ flange, 10-32 internal threat, 3/8" long, .031" flange height (drill holder size "G")

Assembly DetailD1 Detail

D1 Detail

scale: nts

Page 38: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

D2.1548

D2.1548 Area/Destination Plaque

A Plaque1/4" Thick Acrylite Matte Clear FF P 99 Acrylic w/ Polished Returns & (4) 3/8" Holes Drilled Through. Sub-surface applied Frosted Crystal PSV, #775-324.

B Secondary Copy1-1/2” High News Gothic BT Demi; Matte Black PSV (3M Series 220 P20871C), Surface applied

C Primary Copy3” High News Gothic BT Demi; Matte Black PSV (3M Series 220 P20871C), Surface applied

D Rule Line (If Applicable)1/4" x 32" matte Black PSV (3M Series 220 P20871C), Surface applied

E MountSee Page 24

Desk J1-14

Heart and Vascular Surgical Center& Family Waiting

Internal Medicine,Geriatrics & Pediatrics

Desk / Area Identification

Destination Identification

48"

15"

1 5/8"

1 5/8"

2 1/4"

4 3/8"

4 1/2"

A

B

D

C

C

E

1 5/8"

3 7/8"

EQ.

EQ.

38 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

scale: 1-1/2" = 1'-0"

Page 39: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

39 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

Mounting Detail

1/2” thick Drywall

Hollow Wall Anchor

3/4” diameter, 3/4” thick Spacer

3/4” diameter, 5/16” thick Cap

1/4” thick Acrylic Sign Panel

Plastic Washers

Mount(4) Aluminum w/ Satin Stainless Steel Finish #STDA-2424-SS 3/4” Diameter x 5/16” Thick Caps & 3/4” Diameter x 3/4” Thick Spacers w/ Plastic Washers & Mounting Screws

D2 Detail

D2 Detail

scale: nts

Page 40: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

E.1

E.1 ADA Symbol Plaque

WOMEN

Sign Back

Typical LayoutSingle Handicap Restroom

9"

7 3/4"9"

1 7/8"

5/8"

3/8"

5/8"

7 3/4"

A

B

F

C

E

D

1/4"

5/8"

40 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

scale: 4" = 1'-0"

A Plaque1/4" Thick Gloss Clear Acrylic w/ 45° Half Bevel w/ Polished Bevels and Edges, Sub-surface Applied Chrome Scratch Vinyl PSV 9250 (Avery #A1840-S)

B ADA Overlay.037" Polymer Overlay; Surface Painted Matthews Brushed Aluminum #41-342 Applied to Face w/PSA

C Raised Copy3/4" News Gothic BT Demi; All Caps; Raised; Screened Black

D Raised Symbol4" typical; Raised; Screened Black

E Braille25pt; Grade 2; Raised

F Mount(2) 6" x 3/4" White Foam Tape Tabs

* NoteSee Page 26 for alternate symbols & layouts

Page 41: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

41 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

ADA Symbol Plaque Alternate Layouts

RESTROOM

RESTROOM& SHOWER

TELEPHONES& RESTROOMSTELEPHONES

LOCKER ROOM

A

B

3/8"

3/4"

3/8"

7/8"

3/4"

1 1/8"

5/8"

1 7/8"

1/4"

1 7/8"

3/4"

1/4"

1 1/2"

5/8"

3/8"

1 3/4"

1"

5/8"

1/4"

4-1/2” symbol 3” symbol

E.1

A Raised Symbol4” typical (unless otherwise noted); Raised; Screened Black

B Raised Copy3/4” News Gothic BT Demi; All Caps; Raised; Screened Black

E.1

scale: nts

Page 42: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

E.2

E.2 9 x 9 Projected Mount

42 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

see elevation 8

Specifications

TELEPHONE

RESTROOM

Alternate Layout

9"

7 3/4"9"

7 3/4"

1 1/2"

1 1/2"

5/8"

2"

1/8”

EQ. EQ. EQ. EQ.

A

CB

E

F

D

2"

9"

4” Symbol

Top View

Side View

scale: 4" = 1'-0"

A Panels (2-Sided)(2) 1/4" Thick Gloss Clear Acrylic panels w/45° Half Bevel w/ Polished Bevels and Edges; Sub-surface Applied Chrome Scratch Vinyl PSV 9250 (Avery#A1840-S);

B Graphic Area7-3/4" x 7 -3/4" Metallic Silver PSV 9232, Mounted w/ Tabs of VHB Tape

C Filler8-3/4" x 9-1/4" x 1/8" thick Tempered Hardboard, Mounted to Bracket w/ Silicone

D Symbol4"-1/2 typical (unless otherwise noted); Black PSV

E Copy7/8" News Gothic BT Demi; All Caps; Black PSV

F Mount9" x 11/16" x 2” Deep Natural Satin Anodized Aluminum Bracket, (4) 3/16" Holes Drilled Through to Accommodate #8 x 1-1/2" Long Phillips Pan Head Sheet Metal Screws & Plastic Wall Anchors

* NoteHoles Are Drilled So As To Appear Centered In Area When Plaques Are Applied

Page 43: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

F.1

Stair PlaqueF.1

43 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

STAIR A

Fire Door Keep ClosedIn the event of a fire doors unlock automatically

Sign Back

9"

7 3/4"9"

1 7/8"

5/8"

3/8"

5/8"

7 3/4"

G

A

B

D

C

F

E

scale: 4" = 1'-0"

A Plaque1/4" Thick Gloss Clear Acrylic w/ 45° Half Bevel w/ Polished Bevels and Edges, Sub-surface Applied Chrome Scratch Vinyl PSV 9250 (Avery #A1840-S)

B ADA Overlay.037" Polymer Overlay Surface Painted Matthews Brushed Aluminum #41-342; Applied to plaque w/PSA

C CopyFire Door Message: 1/2" News Gothic BT Demi, U/L; Screened Black

Submessage: 1/4" News Gothic BT Demi; U/L; Screened Black

D RaisedCopy(StairIdentification)7/8" News Gothic BT Demi; All Caps; Raised & Screened Black

E Raised Symbol2-3/4", Screened Black

F Braille25pt; Grade 2; Raised

G Mount(2) 6" x 3/4" White Foam Tape Tabs

Page 44: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

G.1

ADA Acrylic Stairwell PlaqueG.1

44 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

STAIR AAccess From LLthru 8th Floor

Exit LL & 1st Floor

4

Sign Back

G

A

B

C

D

E

F

7 3/4"

7 3/4"9"

9"

3"

5/8"

1 3/8"

1 1/8"

3/4"

1"

scale: 3/8" = 1'-0"

A Plaque 1/4" Thick Clear Acrylic w/45° Half Bevel w/ Polished Bevels and Edges; Sub-surface Applied Chrome Scratch Vinyl PSV 9250 (Avery#A1840-S)

B ADA Overlay.037" Polymer Overlay; Surface Painted Matthews Brushed Aluminum #41-342 Applied to Face w/PSA

C Raised Floor Number2" News Gothic BT Demi; Screened Black

D Braille25pt; Grade 2; Raised

E Raised Copy7/8" News Gothic BT Demi; All Caps & Screened Black

F Egress Copy1/2" News Gothic BT Demi; U/L; Screened Black; Max. Line Length 6-3/4"

G Mount(2) 6" x 3/4" White Foam Tape Tabs

Page 45: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

G.2

Stairwell Evacuation Directional PlaqueG.2

45 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

STAIR AAccess From LLthru 8th Floor

Exit LL & 1st Floor

4

5/8" TYP

9"

4 1/2"

3 3/8" 3 3/8"

D

A

B

C

3 3/8"

Sign Type G.1(See Page 29)

13 1/2"overall

5/8" 1"

1/4"

scale: 3/8" = 1'-0"

A Plaque 1/4" Thick Clear Acrylic w/45° Half Bevel w/ Polished Bevels and Edges; Sub-surface Applied Chrome Scratch Vinyl PSV 9250 (Avery#A1840-S);

B Raised Evac Symbol – ADA Overlay.037" Polymer Overlay Surface Painted Black; Applied to Face w/PSA; Door Graphic Raised, Screened Metallic Silver

C Raised Arrow – ADA Overlay.037" Polymer Overlay; Surface Painted Metallic Silver Applied to Face w/PSA; Arrow 1-7/8" x 2-1/8" Raised, Screened Black

NOTE: Apply Arrow on site unless the schedule indicates the direction

D Mount3-1/2" x 3/4" White Foam Tape Tabs Mount Underneath Sign Type G.1

Page 46: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

H

Dimensional LettersH

46 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

3" High, Typ.

A

B

C

scale: 1/2" = 1"

A Dimensional LettersChemetal 902 Horizontal Brushed Aluminum Laminate applied to 1/4" Thick Acrylic; Returns Painted Metallic Silver 41-342

Alternate Finish: 1/4" Thick Acrylic Surface Painted; See Sign Schedule for Color

B CopyNews Gothic BT Demi, U/L; 3" High unless noted in Sign Schedule

C MountDrywall Foam Tape & Silicone

Page 47: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

J.1

ADA Acrylic Window PlaqueJ.1

47 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

see elevation 8

Specifications

scale: 1/2" = 1"

A Face Plaque1/4" Thick Gloss Acrylic with 3 1/4" x 5" window cutout; 45° Half Bevel w/ Polished Bevel and Edges, Sub-surface Applied Chrome Scratch Vinyl PSV 9250 (Avery #1840-S)

B Backer1/8" Thick Acrylic; Polished Edges; Surface Applied Silver Metallic Vinyl PSV 9275 (Avery #A5701)

C InsertSee Page 33

D ADA Overlay.037 Thick Photo Polymer Surface Painted Matthews Brushed Aluminum #41-342 Applied to Face w/ PSA

E Raised Copy5/8" News Gothic BT Demi; All Caps; Screened Black

F Braille25pt; Grade 2; Raised

G Wall Mount(3) 3-1/2" x 3/4" White Foam Tape Tabs

H Pin Mount3" x 5-3/4" x .040 Lexan w/ #56 Hole Drilled Through and Dimpled; Mounted w/ VHB Tape to Plaque; (2) 2" Long Solid Headed Steel Nickel Plated Pins #38051; 7/64" Drill .045 Deep into Back of Backer

OccupationalTherapy

EU1-153C

Side View Backof Face

Backof Backer

Pin Mount Side View

1/2"

6"

1/2"

1/2"

1/8"

1/8"

3 1/4"

6"

7/8"TYP

1 1/2"

A

B

E

F

H

D

G

C

5"

1 5/8"

1/4" 1/8"

Page 48: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

48 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

SpecificationsA Insert

.010 Thick Clear Gerber Lexedge; Printed Black copy; News Gothic BT Demi; see layouts for recommended copy sizes

OccupationalTherapy

If you arePregnant,

Please NotifyTechnologist

4Exam

Lisa Bell, RN, BSNNurse Manager

Nursing Units M30/M35

Gaurav Kapur, MD

Augustio Hsia, MD

3 3/8"

5 31/32"5" visible area

3 1/4"visiblearea

1 1/2"

3/4"

1/2”Copy

3/8”Copy

3/8” Copy

1/4”Copy

7/8"

5/8"

5/8"

5/8"

A3/4"

1/4"

2"

1 3/8"

1/2"

5/8"

1 3/8"

7/8"

J.1

ADA Acrylic Window PlaqueJ.1

scale: 1/2" = 1"

Page 49: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

L1.66

Acrylic Window PlaqueL1.66

49 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

Side View w/ Desk Base

Side View

Co-Payments

are requiredat the time of your

appointment

Thank You

6"

6"

5/8" typ

A

B

E

D

C

5/8"

1/4" 1/8"

4 3/4"

4 3/4"

scale: 1/2" = 1"

A Face Plaque1/4" Thick Gloss Acrylic with 4 3/4" x 4 3/4" window cutout; 45° Half Bevel w/ Polished Bevel and Edges, Sub-surface Applied Chrome Scratch Vinyl PSV 9250 (Avery #1840-S); Attaches to Backer with .045 VHB Tape to Create 4 15/16 x 6" Pocket

B Backer1/8" Thick Acrylic; Polished Edges; Surface Applied Silver Metallic Vinyl PSV 9275 (Avery #A5701)

C InsertSee Page 35

D Wall Mount(2) 5" x 3/4" White Foam Tape Tabs

E Desk Base2-3/4" x 6" x 1/8" Thick Clear Acrylic Base Heat Formed 65° Angle 2" Leg w/ Polished Edges & Mounted to Plaque w/ Optically Clear Tape

Page 50: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

L1.66

Acrylic Window PlaqueL1.66

scale: 1/2" = 1"

50 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

SpecificationsA Insert

.010 Thick Clear Gerber Lexedge; Printed Black copy; News Gothic BT Demi; See layouts for recommended copy sizes

Waiting RoomEXIT

Co-Payments

are requiredat the time of your

appointment

Thank You

1/2”Copy

3/8”Copy

A

5 31/32"

4 3/4" visible area

4 7/8"4 3/4"visiblearea

1 7/8"

3/4"

7/8"

2 3/4"

1 1/8"

3/8"

1/32"ruleline

3/4"

5/8"

5/8"

7/8"

1/2"

**Note: Arrow varies fromone used on other directionals(i.e. D1 types) - verify arrow use

1"

4 3/8"rule line

Page 51: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

L1.99

Acrylic Window PlaqueL1.99

51 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

Side View w/ Desk Base

Side View

Nursing UnitM52

EpilepsyMonitoring

Unit

9"

9"

A

B

E

D

C

5/8" 7 3/4"

5/8"

7 3/4"

1/4" 1/8"

scale: 1/2" = 1"

A Face Plaque1/4" Thick Gloss Acrylic with 7 3/4" x 7 3/4" window cutout; 45° Half Bevel w/ Polished Bevel and Edges, Sub-surface Applied Chrome Scratch Vinyl PSV 9250 (Avery #1840-S); Attaches to Backer with .045 VHB Tape to Create 7 15/16" x 9" Pocket

B Backer1/8" Thick Acrylic; Polished Edges; Surface Applied Silver Metallic Vinyl PSV 9275 (Avery #A5701)

C InsertSee Page 37

D Wall Mount(2) 6" x 3/4" White Foam Tape Tabs

E Desk Mount2-3/4" x 9" x 1/8" Thick Clear Acrylic Base Heat Formed 65° Angle 2" Leg w/ Polished Edges & Mounted to Plaque w/ Optically Clear Tape

Page 52: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

L1.99

Acrylic Window PlaqueL1.99

scale: 3" = 1'-0"

52 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

SpecificationsA Insert (Clear)

.010 Thick Clear Gerber Lexedge; Printed Black copy; News Gothic BT Demi; See layouts for recommended copy sizes

B Insert (Opaque)HP Heavyweight Coated Paper; Printed red background with reversed out copy; see layout for recommended copy sizes

Nursing UnitM52

EpilepsyMonitoring

Unit

Exams 14-1

HematologyConference Rm.T Building

AuthorizedPersonnelOnlyNo Admittance

A

B

1/16"ruleline

7 3/4"visiblearea

7 7/8"

8 31/32"

7 3/4"

2"

1 1/8"

1 1/2"

1 1/8"

1 1/8"

1"

1 5/8"

1"

1"

5/8”Copy

3/4”Copy

2 3/8"

Ø 1 5/8"

3 1/2"

1"

1"

1/2"

1"

1 7/8"

2 1/4"

3/4" arrow

Page 53: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

L1.1414

Large Window PlaqueL1.1414

53 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

see elevation 8

Specifications

Side View w/ Desk Base

Side View

Partition Mount

Radiology 1, 2 & 3Waiting Room

Ultrasound 2Bone DensityGeneral Surgery

14"

14"

5/8" typ.

F

A

B

E

C

D

Part A1 1/8"typ.

Part B : 1 3/4"

5"

5/8" 12 3/4"

12 3/4"

scale: 3" = 1'-0"

A Face Plaque1/4" Thick Gloss Clear Acrylic with 12 3/4" x 12 3/4" window cutout; 45° Half Bevel w/ Polished Bevel and Edges, Sub-surface Applied Chrome Scratch Vinyl PSV 9250 (Avery #1840-S); Attaches to Backer with .045 VHB Tape to Create 12-15/16 x 14" Pocket

B Backer3mm Thick Grey Komatex

C InsertSee Page 39

D Wall(2) 11" x 3/4" White Foam Tape Tabs

E Partition Mount(2) .063” thick satin anodized aluminum angles (Part A: 6 1/8” x 8” wide; Part B: 2 13/16” x8” wide); Part A attaches to panel with white foam tape; 1/2” x 7-3/4” VHB tape applied to underside of Part A to attach to Part B; Adjust space between angles to accommodate width of partition

F Desk 2-3/4" High x 14" Wide x 2" Leg x 1/8" Thick Clear Bent Acrylic Base w/ Polished Edges & 65° Angle Mounted to Plaque w/ Optically Clear Tape

Page 54: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

L1.1414

Large Window PlaqueL1.1414

scale: 3" = 1'-0"

54 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

SpecificationsA Insert

.010 Thick Clear Gerber Lexedge; Printed Black copy; News Gothic BT Demi; See layouts for recommended copy sizes

Radiology 1, 2 & 3Waiting Room

Ultrasound 2Bone DensityGeneral Surgery

A

3/4” Copy

12 3/4"visiblearea

12 7/8"

12 3/4"visible area

13 31/32"

3 7/8"

1 1/4"

2"

1 1/4"

1 1/8"

2" 1 1/2"

7/8"

Page 55: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

L1.1814

Large Acrylic Window PlaqueL1.1814

55 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

Sign Backer BackSide View

14"

18"

A

B

C

D

5/8"

16 3/4"

5/8"12 3/4"

scale: 3/16" = 1"

A Face Plaque1/4" Thick Gloss Clear Acrylic with 16 3/4" x 12 3/4" window cutout; 45° Half Bevel w/Polished Bevel and Edges, Sub-surface Applied Chrome Scratch Vinyl PSV 9250 (Avery #1840-S); Attaches to Backer with .045 VHB Tape to Create 16-15/16" x 14" Pocket

B Backer3mm Thick Grey Komatex

C InsertSee Page 41

D Wall Mount(2) 17" x 3/4" White Foam Tape Tabs

Page 56: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

L1.1814

Large Acrylic Window PlaqueL1.1814

scale: 3/16" = 1"

56 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

SpecificationsA Insert

.010 Thick Clear Gerber Lexedge; Printed Black copy; News Gothic BT Demi; See layout for recommended copy sizes

13 31/32"

12 3/4"visible area

16 3/4"visible area

16 7/8"

Layout GuidelinesTBD - Does not appearto be News Gothic Demi?

A

Page 57: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

L1.3015

L1.3015

57 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

Large Window Plaque

Patient Rooms

Patient RoomsPT/OT Gym

Pain Management

Floor 4

Floor 3

Patient Rooms

Patient Rooms

Patient Rooms

Patient Rooms

Floor 5

Floor 6

Floor 7

Floor 8

Cafeteri a / Vending

ICUSurger y

Floor G

Main LobbyGift ShopChapelEmergenc yPatient RegistrationLaborator yRadiologyCCU

Sign Backer BackSide View

5/8" TYP

30"

B

A

C

D

13 3/4"

15"

28 3/4"

scale: 3/16" = 1"

A Face Plaque1/4" Thick Gloss Clear Acrylic with 13 3/4" x 28 3/4" window cutout; 45° Half Bevel w/ Polished Bevel and Edges, Sub-surface Applied Chrome Scratch Vinyl PSV 9250 (Avery 1840-S); Attaches to Backer with .045 VHB Tape to Create 28-15/16" x 15" Pocket

B Backer3mm Thick Grey Komatex

C Insert See Page 43

D Wall Mount(2) 29" x 3/4" White Foam Tape Tabs

Page 58: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

L1.3015

L1.3015 Large Window Plaque

scale: 3/16" = 1"

58 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

SpecificationsA Insert

.010 Thick Clear Gerber Lexedge; Printed Black copy; News Gothic BT Demi; See layout for recommended copy sizes

Patient Rooms

Patient RoomsPT/OT Gym

Pain Management

Floor 4

Floor 3

Patient Rooms

Patient Rooms

Patient Rooms

Patient Rooms

Floor 5

Floor 6

Floor 7

Floor 8

Cafeteri a / Vending

ICUSurger y

Floor G

Main LobbyGift ShopChapelEmergenc yPatient RegistrationLaborator yRadiologyCCU

28 3/4"28 7/8"

15"13 3/4"

Layout GuidelinesTBD - Current?

A

Page 59: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

M.1

Vinyl LettersM.1

59 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

SpecificationsA PSV Letters

Cut vinyl copy; News Gothic BT Demi; U/L; See schedule for colors

Want to set standard?

Rehabilletter heightvaries

A

scale: nts

Page 60: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

M.2

Entry Door VinylM.2

scale: 1-1/2" = 1'-0"

60 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

Family Health CenterChagrin Falls551 E. Washington Street

551 E. Washington StreetChagrin Falls

URGENT CARE

551 E. Washington StreetChagrin Falls

URGENT CAREFamily Health CenterChagrin Falls551 E. Washington Street

C

B

A

D

width varies per location

12 1/2"

1 3/4"

1 3/4"

1 5/8"

2"

1 3/4"

1 3/4"

1 5/8"

1 3/8"

8 5/8"

8 1/2" 19 3/8"

Elevation

Panel A Panel B

Panel A Detail

Panel B Detail

*Alternate Cleaned-up Layouts Proposed

60"

3 7/8"

A Etched Vinyl BandReverse-applied etched PSV 9031

B CCF LogoSurface-applied PSV; transparent Deep Sky Blue Gerber Vinyl #P5167A and Bright Green Vinyl #P35341A (logo mark) and Black PSV (logo type)

C Copy1-1/8" News Gothic BT Demi; U/L; Surface Applied Black PSV

D Urgent Care BlockSurface-Applied Red PSV (3M #220-13); White PSV copy

Page 61: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

M.3

Call Light Vinyl NumbersM.3

scale: nts

61 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

366366

Horizontal Layout

(2) of Each Number

Vertical Layout

(2) of Each Number

A Vinyl NumbersSize and Layout varies per location; News Gothic BT Demi; Black Surface Applied PSV

Page 62: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

N

Fire Extinguisher VinylN.1 & N.2

62 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

FIRE

1 3/8" 2 3/4"

A

B

N.1Front of Cabinet

N.2Side of Cabinet

ALIGN TO TOPOF DOOR ON FRONT

4"

1 7/8"

1 1/4"

2"

1 1/8"

14 5/8"

scale: 3/16" = 1"

A Symbol (per Code 1894)Red cut PSV (3M #220-13) applied to Face of Cabinet

B Symbol & Copy (per Code 1893)Cut Red PSV (3M #220-13) Symbol & Copy; News Gothic BT Demi; All Caps; Qty. (2) required

Page 63: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

OH.1414

Overhead SignOH.1414

63 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

LobbyEXIT/

CardiacRehab

A

C

B

D

14"

14"

3"

2"

3"

2"

2 1/4"

1 1/8"

3 3/4"

1/4"

1 1/8"

Side View

scale: 3/16" = 1"

A Double-Sided Overhead PanelCM902 Brushed Aluminum Laminate applied to 1" Thick Wood Core; 1/4" 45° Bevel; Returns Surface Painted Matthews Brushed Aluminum #41-342

B Copy2" News Gothic BT Demi; U/L; Surface Applied Black PSV

C ArrowSurface Applied Black PSV

D MountCeiling Hung; See Page 49

Page 64: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

OH.1424

Overhead SignOH.1424

64 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

CoronaryIntensive Care Unit

J3-1A2"

4 1/2"

1 7/8"

2 1/8"

A

B

C

D

E

14"

24"

1 1/8"

1/4"19 1/2"

Side View

scale: 3/16" = 1"

A Double-Sided Overhead PanelCM902 Brushed Aluminum Laminate applied to 1" Thick Wood Core; 1/4" 45° Bevel; Returns Surface Painted Matthews Brushed Aluminum #41-342

B Copy1-1/2" News Gothic BT Demi; U/L; Black Surface Applied PSV

C Rule LineBlack Surface Applied PSV

D Desk Number3" News Gothic BT Demi; U/L; Black Surface Applied PSV

D MountCeiling Hung; See Page 52

Page 65: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

OH.1048

Overhead SignOH.1048

65 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

DO NOT ENTERAuthorized Personnel Only

10"

48"

4"

2 5/8"

A

B

D

C

SideView

1"

3"

3"

scale: 1-1/2" = 1'-0"

A Double-Sided Overhead PanelCM902 Brushed Aluminum Laminate applied to 1" thick Korpine with 1/4" 45° Bevels; Returns Surface Painted Matthews Brushed Aluminum #41-342

B Copy1-7/8" News Gothic BT Demi; All Caps ("DO NOT...") and U/L ("Authorized..."); Black surface applied PSV

C Symbol4" Diameter; surface applied Red & White PSV

D MountCeiling Hung, See Page 52

Page 66: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

OH.66

Overhead SignOH.66

66 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

23O.R.

23

3 1/4"

1 1/4"

1 1/4"

A D

B

C

1 1/8"

6"

6"

scale: 1/2" = 1'-0"

A Double-Sided Overhead PanelCM??? Brushed Aluminum Laminate applied to 1" Thick MDF; 1/4" 45° Bevels; Returns Surface Painted Matthews Brushed Aluminum #41-342

B Copy3/4" News Gothic BT Demi; All Caps; surface applied Black PSV

C Number2-3/4" News Gothic BT Demi; surface applied Black PSV

D MountCeiling Hung w/ (2) 1/4" - 20 Threaded Rods; 1" in From Ends

(*Different from OH Detail Page 52?)

Page 67: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

67 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

L

Drywall Ceiling Mount

Ceiling Mount Side View

Drop Ceiling Mount

“T” Grid

Toggle Bolt

Toggle Bolt

1” x 1” x 36”Aluminum U-Channels

1/4-20 x 4” threadedmachine screws

Drill holes & countersinkto accommodate a #10 x 2” FHWS Phillips

Ceiling Tile Drywall

1/2” x 1-1/2”counterborew/ 5/16” hole drilled through

Screw heads are paintedto match backgroundcolor of sign

1/4-20 x 4” threadedmachine screws

14"

7/8"1 7/8"

size varies1" 1"size varies

1/4" smallerthan above2"

typ.

2 3/8" 2 1/2" pocket

OH Detail

Mounting DetailOH Detail

scale: 1-1/2" = 1'-0"

Page 68: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

P.1

ADA Acrylic Window PlaqueP.1

68 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

Side View Back of Sign

Insert Detail

Women'sLocker Room

Women'sLocker Room

INI-1051/8"

6"

1/2"1/8"

5/8"

A

F

B

G

C

C

E

D

1 5/8"

9"

9"

5/8" 7 3/4"1/4" 1/8"

1 1/8"

2 3/8"

6"visiblearea

6 1/8"

7 3/4"visible area

9"

scale: 3/8" = 1"

A Face Plaque1/4" Thick Clear Acrylic with 6" x 7 3/4" window cutout; 45° Half Bevel w/ Polished Bevel and Edges, Sub-surface Applied Chrome Scratch Vinyl PSV 9250 (Avery #1840-S)

B Backer1/8" Thick Acrylic; Polished Edges; Surface Applied Silver Metallic Vinyl PSV 9275 (Avery #A5701)

A Insert.010 Thick Clear Gerber Lexedge; Printed Black copy; 3/4" News Gothic BT Demi

D ADA Overlay.037 Thick Photo Polymer Surface Painted Matthews Brushed Aluminum #41-342 Applied to Face w/ PSA

E Raised Copy5/8" News Gothic BT Demi; All Caps; Screened Black

F Braille25pt; Grade 2; Raised

G Wall Mount(2) 6" x 3/4" White Foam Tape Tabs

Page 69: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Q.10

6 x 6 Acrylic PlaqueQ.10

69 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

SterileAttireRequired

ProperAttireRequired

Side View

Alternate Message

6"

6"

1/2"

3/4"

3/4"

2 3/4"

1/2" A

B

C

D

1/8"

scale: 1/2" = 1"

A Plaque1/8" Red RH #2157 Acrylic; 45° Full Bevel; Painted Matte Clear Coat

B Copy1/2" News Gothic BT Demi; U/L; Surface Screened White

C Rule Line1/16" x 3-1/2"; Surface Screened White

D Mount(1) Roll Pin (Center/Center) and Silicone

(Not shown?)

Page 70: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Q.11

6 x 6 Acrylic PlaqueQ.11

70 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

AuthorizedPersonnelOnly

No Admittance

AuthorizedPersonnelOnly

AuthorizedAccessONLY

Side View

Alternate Messages

1/2"

6"

6"

1/2"

3/4"

3/4"

1 1/4"

1"

5/8"

A

B

C

D

E

F

1/2"

3 1/2"

1/8"

scale: 1/2" = 1"

A Plaque1/8" Red RH #2157 Acrylic; 45° Full Bevel; Painted Matte Clear Coat

B Symbol1-1/4" Dia; Surface Screened White

C Copy3/8" News Gothic BT Demi; U/L; Surface Screened White

D Rule Line1/16" x 3-1/2"; Surface Screened White

E Copy1/2" News Gothic BT Demi; U/L; Surface Screened White

F Mount(2) 5" x 3/4" White Foam Tape Tabs

Page 71: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Q.12

6 x 6 Acrylic PlaqueQ.12

71 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

In case of fire,doors willautomaticallyunlock.

Side View

1/2"

6"

6"

A

B

C

1 1/2"

3/4"

3/4"

3/4"

1/8"

scale: 1/2" = 1"

A Plaque1/8" Red RH #2157 Acrylic; 45° Full Bevel; Painted Matte Clear Coat

B Copy1/2" News Gothic BT Demi; U/L; Surface Screened White

C Mount(2) 5"x3/4" White Foam Tape Tabs

Page 72: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Q.13

6 x 6 Acrylic PlaqueQ.13

72 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

EmergencyEXIT ONLY

Door SoundsAlarm

Side View

1/2"

6"

6"

1/2"

3/4"

1 1/4"

1"

5/8"

9/16"

A

B

F

D

E

C

1/2"

1/8"

scale: 1/2" = 1"

A Plaque1/8" Red RH #2157 Acrylic; 45° Full Bevel; Painted Matte Clear Coat

B Symbol1-1/4" Dia; Surface Screened White

C Copy3/8" News Gothic BT Demi; U/L; Surface Screened White

D Rule Line1/16" x 3-1/2"; Surface Screened White

E Copy1/2" News Gothic BT Demi; U/L; Surface Screened White

F Mount(2) 5" x 3/4" White Foam Tape Tabs

Page 73: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Q.14

6 x 6 Projected MountQ.14

73 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

Top View

Side View

Defib

2"

6"

1”

1/2"

5/8" TYP

A

B

E

C

D

2"

5/8" 6"

1/8" 1/8" 1/8"EQ.EQ.EQ.EQ.

6 5/16"

5 3/4"

scale: 1/2" = 1"

A Double-Sided Plaque(2) 1/8" Red RH #2157 Acrylic; 45° Full Bevel; Painted Matte Clear Coat

B Filler1/8" Thick Tempered Hardboard, Mounted to Bracket w/ Silicone

C Symbol4" Diameter; Surface Screened White

D Copy5/8" News Gothic BT Demi; U/L; Surface Screened White

E Mount6" x 11/16" x 2" Natural Satin Anodized Aluminum Bracket, (4) 3/16" Holes Drilled Through to Accommodate #8 x 1-1/2" Long Phillips Pan Head Sheet Metal Screws & Plastic Wall Anchors

Page 74: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

74 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

Alternate Message #2Alternate Message #1

Crash CartFire Extinguisher

A

B

1/2"

1"

3 7/8"

A Symbol3 7/8" Diameter; Surface Screened White

B Copy1/2" News Gothic BT Demi; U/L; Surface Screened White

Q.14

6 x 6 Projected MountQ.14

scale: 1/2" = 1"

Page 75: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Q.15

6 x 6 Acrylic PlaqueQ.15

75 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

Radioactive Material

Side View

1/2"

6"

1/2"

2 3/4"

7/8"D

E

B

C

A 1/8"

1 3/8"

scale: 1/2" = 1"

A Plaque1/8" Thick Acrylic; 45° half Bevel; Surface Painted OSHA Yellow S12

B Header Block1-1/4" x 5-11/16"; 3/4" News Gothic BT Demi Copy; All Caps; Intaglio Surface Screened S54 OSHA Purple

C Symbol2-3/4" High; Surface Screened S54 OSHA Purple

D Copy3/8" News Gothic BT Demi; U/L; Surface Screened S54 OSHA Purple

E Mount(2) 5" x 3/4" White Foam Tape Tabs

Page 76: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Q.15a

3 x 3 Acrylic PlaqueQ.15a

76 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

Radioactive Material

*Changed panel to 1/8”?

Side View

1/4"

1 3/8"

7/16"

5/8"

3"

3"

D

E

B

C

A1/8"

scale: 1" = 1"

A Plaque1/8" Thick Acrylic; 45° half Bevel; Surface Painted OSHA Yellow S12

B Header Block5/8" x 2 3/4"; 3/8" News Gothic BT Demi Copy; U/L; Intaglio Surface Screened S54 OSHA Purple

C Symbol1-3/8" High; Surface Screened S54 OSHA Purple

D Copy3/16" News Gothic BT Demi; U/L; Surface Screened S54 OSHA Purple

E Mount(2) 2" x 3/4" White Foam Tape Tabs

Page 77: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Q.16

6 x 6 Acrylic PlaqueQ.16

77 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

Authorized Personnel Only

BIOHAZARDOUSMATERIAL

6"

1/2"

6" 2 3/4"

7/8"

D

E

C

B

A

1/4"

3/4"

5/8"

scale: 1/2" = 1"

A Plaque1/4" Thick Acrylic w/45° Half Bevel; Surface Painted Matthews Brushed Aluminum #41-342

B Header Copy7/16" News Gothic BT Demi; All Caps; Surface Screened S52 OSHA Blue

C Symbol2 3/4" High, Surface Screened S2 OSHA Red

D Copy5/16" News Gothic BT Demi; U/L; Intaglio Surface Screened S52 OSHA Blue

E Mount(2) 5" x 3/4" White Foam Tape Tabs

Page 78: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Q.17

Q.17 6 x 6 Acrylic Plaque

78 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

EyeWashStation

Side View

6"

6" D

A

B

C

1/4"

1 1/4"1 3/8"

1 1/8"

1 1/8"

1"

scale: 1/2" = 1"

A Plaque1/4" Thick Acrylic w/ 45° Half Bevel; Surface Painted Matthews Brushed Aluminum #41-342

C Copy Block1-1/4" x 5-11/16"; 3/4" News Gothic BT Demi; All Caps; Intaglio Surface Screened S51 OSHA Green

B Copy3/4" News Gothic BT Demi; U/L; Surface Screened Black

D Mount(2) 5" x 3/4" White Foam Tape Tabs

Page 79: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Q.18

Q.18 6 x 6 Acrylic Plaque

79 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

Food and BeveragesNot Permitted

Side View

6"

6"

7/16"

7/16"

5/8" TYP

C

D

B

A

1/4"

scale: 1/2" = 1"

A Plaque1/4" Thick Acrylic w/ 45° Half Bevel; Surface Painted Matthews Brushed Aluminum #41-342

B Symbol3-3/4" Diameter; Surface Screened Black & Red

C Copy3/8" News Gothic BT Demi; U/L; Surface Screened Black

D Mount(2) 5" x 3/4" White Foam Tape Tabs

Page 80: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Q.19

Q.19 6 x 6 Acrylic Plaque

80 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

RestrictedArea

Side View

6"

6"

1/2"

1/2"

1 1/4"

1"

3/4"

C

D

B

A

1/8"

scale: 1/2" = 1"

A Plaque1/8" Red RH #2157 Acrylic; 45° Full Bevel; Painted Matte Clear Coat

B Symbol1-1/4" Diameter; Surface Screened White

C Copy1/2" News Gothic BT Demi; U/L; Surface Screened White

D Mount(2) 5" x 3/4" White Foam Tape Tabs

Page 81: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Q.2

Q.2 6 x 6 Acrylic Plaque

81 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

PLEASEUnlock Both Doors

When Leaving

LOCKBoth Doors For

PrivacyDISABLEDRESTROOMLocated on

First Floor/Lobby

Side View

Alternate Messages

6"

6"

C

D

B

A

1/8"

3/4"

3/4"

2"

3/4"

3/4"

3/4"

3/4"

7/8"

scale: 1/2" = 1"

A Plaque1/8" Thick Acrylic w/ 45° Full Bevel; Surface Painted Matthews Brushed Aluminum #41-342

B Copy1/2" News Gothic BT Demi; U/L; Surface Screened Black

C Symbol1-1/2" High; Surface Screened Black

D Mount(2) 5" x 3/4" White Foam Tape Tabs

Page 82: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Q.22

Q.22 9 x 9 Acrylic Plaque

82 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

RoofAccess

NOEXIT

Side View

Alt Message

9"

9"

A

B

C

2"

3/4"

1"

2 5/8"

2 1/4"

2 5/8"

1/8"

scale: 3/8" = 1"

A Plaque1/8" Red RH #2157 Acrylic; 45° Full Bevel; Painted Matte Clear Coat

B Copy1-1/2" News Gothic BT Demi (unless otherwise noted); U/L; Surface Screened White

C Mount(2) 6" x 3/4" White Foam Tape Tabs

Page 83: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Q.23

Q.23 9 x 9 Acrylic Plaque

83 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

SideView

Not PermittedFood and Beverages

9"

9"

5/8"

A

B

C

D

5/8"

1/4"

1 1/8"

7/8"

scale: 3/8" = 1"

A Plaque1/4" Thick Acrylic w/ 45° Half Bevel; Surface Painted Matthews Brushed Aluminum #41-342

B Symbol5-5/8"; Surface Screened Black & Red

C Copy5/8" News Gothic BT Demi; U/L; Surface Screened Black

D Mount(2) 6" x 3/4" White Foam Tape Tabs

Page 84: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Q.24

Q.24 6 x 6 Acrylic Plaque

84 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

VisitorsOnly

Visitor OnlyPer Patient

Side View

6"

6"

C

D

E

B

A

2 1/4"

1"

1"

1/2"

7/8"

4 1/4"

3/32"

1/2” Copy

1/4"

scale: 1/2" = 1"

A Plaque1/4" Thick Acrylic w/ 45° Half Bevel; Surface Painted Matthews Brushed Aluminum #41-342

B Number1-1/4" News Gothic BT Demi; Surface Screened Black

C Copy5/8" (unless otherwise noted) News Gothic BT Demi; U/L; Surface Screened Black

D Rule LineSurface Screened Black

E Mount(2) 5" x 3/4" White Foam Tape Tabs

Page 85: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Q.25

Q.25 9 x 9 Acrylic Plaque

85 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

And Comfort OfAll Our Patients,

2 VisitorsPer Patient

Side View

Alternate Message

For The Privacy

And Comfort OfAll Our Patients,

1 VisitorPer Patient

For The Privacy

9"

9"A

B

C

1/4"

1 1/8" typ.

1 7/8"

scale: 3/8" = 1"

A Plaque1/4" Thick Acrylic w/ 45° Half Bevel; Surface Painted Matthews Brushed Aluminum #41-342

B Copy3/4" News Gothic BT Demi; U/L; Surface Screened Black

C Mount(2) 6" x 3/4" White Foam Tape Tabs

Page 86: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Q.26

Q.26 9 x 9 Acrylic Plaque

86 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

SpecificationsA Plaque

1/8" Red RH #2157 Acrylic; 45° Full Bevel; Painted Matte Clear Coat

B Copy1/2" News Gothic BT Demi; U/L; Surface Screened White

C Mount(2) 5" x 3/4" White Foam Tape Tabs

Side View

Push UntilAlarm Sounds.Door Can BeOpenedIn 15 Seconds

6"1/8"

6"

1 1/2"

3/4" typ.

1/2"

scale: 1/2" = 1"

Page 87: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Q.3

Q.3 13 x 13 Acrylic Plaque

87 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

scale: 3" = 1'-0"

If you have beenwaiting longerthan 20 minutes,from your scheduledappointment time,please notify thereceptionist.

If you have beenwaiting longerthan 30 minutes,from your scheduledappointment time,please notify thereceptionist.

If you have beenwaiting longerthan 15 minutes,from your scheduledappointment time,please notify thereceptionist.

Alternate Messages

Side View

13"

13"

4"

A

B

C

1/8"

1 1/8"

1 1/8" typ.

1 5/8"

D

A Plaque1/8" Thick P68 Matte Acrylic; Subsurface Painted Metallic Silver M45

B Symbol3 3/8" High; Subsurface Screened Black

C Copy3/4" News Gothic BT Demi; U/L; Subsurface Screened Black

D Desk Base1/2" Thick x 3" Wide x 10" Long Acrylic base w/ 1/8" wide x 1/4" deep Slot; Surface Painted Metallic Silver M45

Page 88: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Q.8

Q.8 6 x 6 Acrylic Plaque

88 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

If you arepregnant, notifytechnologist

radiology exam.before

Side View

6"

6"

C

B

A

1/8"

1/2"

1 3/4"

3/4" typ.

scale: 1/2" = 1"

A Plaque1/8" Red RH #2157 Acrylic; 45° Full Bevel; Painted Matte Clear Coat

B Copy1/2" News Gothic BT Demi; U/L; Surface Screened White

C Mount(2) 5" x 3/4" White Foam Tape Tabs

Page 89: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

RV

RV Vinyl Door Tag

89 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

INI-1051"

3 1/2"

A

B

scale: 1" = 1"

A Tag1" x 3-1/2" Silver Metallic PSV 9275 (Avery #A5701)

B Copy1/2" News Gothic BT Demi; All Caps; Surface Printed Black

Page 90: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

S.1

S.1 Acrylic Fire Evacuation Plaque

90 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

Fire Evacuation

13"

13"

9/32"

3/4"

9 7/8"

5/8"

D

E

B

A

C

1/2"

*Italic nowhereelse in program?

12"

scale: 3" = 1'-0"

A Face PlaqueCM902 Brushed Aluminum Laminate applied to 1/8" Thick Matte Clear Acrylic; Routered Edges; 9 7/8" x 12" window cutout; Attaches to Backer with .045 VHB Tape to Create 10 1/4" x 13" Pocket

B Backer1/8" Thick Black Acrylic?; Routered Edges

C Header Copy1" News Gothic BT Demi; Skewed 8 degrees?; Surface Screened S 20 Red

D Insert10-1/8" x 12-31/32" (By Others)

F Mount(2) 12" x 3/4" White Foam Tape Tabs

Page 91: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

T.1

T.1 Acrylic Slide Plaque

91 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

In Use(SLIDE)

In Use InConference

Meetingin Progress

X-RayIn Use

Case InProgress

Do Not Enter

Side View

Alternate Messages

6"

3"

C

F

D

E

B

A

2 3/16" 1 3/4"

4 3/4"

2 5/8"

5 1/4"

5/8"

Copy 9/32”

scale: 3/4" = 1"

A Face Plaque1/4" Thick Clear Acrylic w/ 45° Half Bevel w/ Polished Bevel and Edges; Sub-surface Applied Chrome Scracth Vinyl PSV 9250 (Avery #A1840-S); 1-3/4" x 4-3/4" Window Cutout

B Filler.080 Thick Clear Acrylic; 2-1/4" x 5-1/4" Window Cutout; Polished Edges

C Backer1/16" Thick Clear Acrylic; Polished Edges w/ Surface Applied Silver Metallic Vinyl PSV 9275 (Avery #A5701)

D Slide1/16" Clear Gloss Acrylic w/ Surface Applied Silver Metallic Vinyl PSV 9275 (Avery #A5701)

E Copy on Backer5/16" (unless otherwise noted)News Gothic BT Demi; U/L; Surface Screened Black w/ Clear Gloss Mylar applied (to protect copy from slide)

F Mount(2) 2" x 3/4" Wide White Foam Tape Tabs

Page 92: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

U.2

U.2 Bent Acrylic Insert Holder

92 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

.025"Opening

Top View

Side View

Iris KristensenProject Manager/Analyst

JJ1-701d

6"

3 1/2"

AC

B

B

White Foam Tape

Metallic Silver Ink Screened on Backside

3"1 1/2"

3/4"

3/4"

scale: 1/2" = 1"

A HolderV#516 1/8" Thick Clear Gloss, Heat-Formed Cast Acrylic w/ Polished Returns and Metallic Silver Ink Screened on Back Side

B InsertsSee Page 78

C Mount3/4" x 3/4" x 3" wide, 1/16" Aluminum Extrusion; Satin Finish; Adhered to Back Side of Holder at Top Center w/ (1) 1/2" x 3" Wide 3M4950 VHB Tape; Hangs on Partition Wall w/ 3/8" x 1-1/2" White Foam Tape

Page 93: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

93 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

SpecificationsA Inserts

(2) .010" Thick Clear Lexedge

B Name1/2" High News Gothic BT Demi; U/L; Printed Black

C Specialty1/4" High News Gothic BT Demi; U/L; Printed Black

D Number3/8" High News Gothic BT Demi; U/L; Printed Black

Iris KristensenProject Manager/Analyst

JJ1-701d

Name Insert

Number Insert

3 3/8"

5 31/32"

1"

1/2"

1/2"

A

B

C

D

U.2

U.2 Bent Acrylic Insert Holder

scale: 1/2" = 1"

Page 94: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

94 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

SpecificationsA Holder

V#516 1/8" Thick Clear Gloss, Heat-Formed Cast Acrylic w/ Polished Returns and Metallic Silver Ink Screened on Back Side

B InsertsSee Page 80

C Mount3/4" x 3/4" x 3" wide, 1/16" Aluminum Extrusion; Satin Finish; Adhered to Back Side of Holder at Top Center w/ (1) 1/2" x 3" Wide 3M4950 VHB Tape; Hangs on Partition Wall w/ 3/8" x 1-1/2" White Foam Tape

.025"Opening

Iris KristensenProject Manager / Analyst

JJ1-701d

Top View

Side View

8 1/4"

3 1/8"

White Foam Tape

Metallic Silver InkScreened on Back

3/4"

3/4"

1 1/2"

3"

AC

B

B

U.3

U.3 Bent Acrylic Insert Holder

scale: 1/2" = 1"

Page 95: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

95 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

SpecificationsA Inserts

(2) .010" Thick Clear Lexedge

B Name1/2" High News Gothic BT Demi; U/L; Printed Black

C Specialty1/4" High News Gothic BT Demi; U/L; Printed Black

D Number (& Multi-Name)3/8" High News Gothic BT Demi; U/L; Printed Black

Iris KristensenProject Manager/Analyst

JJ1-701d

Stephanie Hadley, R.Ph.Megan Hemminger, Pharm.D.

Marcie Parker, Pharm.D.

Name Insert

Multiple Name(s) Insert

Number Insert

5/8"

5/8"

5/8"

1/2"

3"

8 1/4"

1"

1/2"

A

B

C

D

D

U.3

U.3 Bent Acrylic Insert Holder

scale: 1/2" = 1"

Page 96: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

V.4

V.4 9 x 9 Acrylic Plaque

96 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

*Alternate Symbol Proposed &Symbol size reduced from 5.5” to 5”

Cellular Phone UseProhibited

Side View

Side View

9"

9"

A

C

D

B

1/4"

5"

1 1/4"

1 1/8"

7/8"

scale: 1/2" = 1"

A Plaque1/4" Thick Acrylic w/ 45° Half Bevel; Surface Painted Matthews Brushed Aluminum #41-342

B Copy5/8" High News Gothic BT Demi; U/L; Surface Screened Black

C Symbol5" High Symbol, Surface Screened Black & Red

D Mount(2) 6" x 3/4" White Foam Tape Tabs

Page 97: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

V.6

V.6 9 x 9 Acrylic Plaque

97 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

Cellular PhoneSafe Zone

*Alternate Symbol & Layout Proposed;Added underline to “Only”

*Why isn’t header top aligned (typ?)

Cellular PhoneUsage Permitted

Only in SafeZone Areas

Side View

9"

9"

A

D

E

C

B

3/8"

2 1/4"

7/8"

1"

1 3/4"

5/8" typ.

1/4"

7/8"

1 3/8"

scale: 1/2" = 1"

A Plaque1/4" Thick Acrylic w/ 45° Half Bevel; Surface Painted Matthews Brushed Aluminum #41-342

B Header2-3/16" x 8-3/4" OSHA Green 51 Surface Screened Rectangle w/ 5/8" High News Gothic BT Demi copy; U/L; Surface Screened White

C Copy3/8" High News Gothic BT Demi; U/L; Surface Screened Black

D Symbol4 3/4" High, Surface Screened Black

E Mount(2) 6" x 3/4" White Foam Tape Tabs

Page 98: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

WH.1414

WH.1414 Wall Hung Sign (Projected Mount?)

98 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

Center forQuality

Leadership

CCHS

RESTROOM

*Changed RestroomCopy to Match E2

2"

2 1/4" typ.

14"

A

B

D

E

C

F

Sample Message Alternate Message (Symbol)

14"

2 7/8"

1 1/2"

scale: 3/16" = 1"

A Double-Sided Projected Mount Panel.025" Thick CM902 Horizontal Brushed Aluminum Laminate applied to 1" Thick Wood Core; 1/4" 45° Bevel; Returns Surface Painted Matthews Brushed Aluminum #41-342

B Copy1-1/2" News Gothic BT Demi; U/L; Black PSV

C MountSee Page 84

D Symbol Background11-1/2 x 11-3/4" Silver 3M 230 PSV

E Symbol6 1/8" High; Printed Black

F Copy1 3/8" News Gothic BT Demi; All Caps; Printed Black

Page 99: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

99 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

Top View

Mounting Detail

Drywall Wall Mount

2" typ.

12" 11 3/4"14"

1"

2 3/8"

2 1/2"

7/8"

1 7/8"

Screwheads painted tomatch background color

1/2” x 1 1/2” counterborew/ 5/16” hole drilled through

Drill holes & countersinkto accommodate a #10 2” FHWS Phillips

Drywall

Toggle Bolt

1/4-20 x 4” threadedmachine screw

WH.1414 Detail

WH.1414 Detail Wall Hung Sign Mounting Detail

scale: 3/16" = 1"

Page 100: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

X

X Informational Window Plaque

100 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

JointClass

Vertical Orientation Side View

Horizontal Orientation

9 1/4"

11 5/16"

B

A

D

C

1/4" VHB Tape; (2) 11 5/16"Left & Right; (1) 8" Bottom

1/2"

1/4"8 1/4"

10 3/8"

scale: 3" = 1'-0"

A Face Plaque1/8" Thick Clear Acrylic w/ Polished Edges; 3/4" Diameter x 3/8" Deep Thumb Slot; Sub-surface Applied Chrome Scratch Vinyl PSV 9250 (Avery #A1840-S) w/ 8 1/4" x 10 3/8" Window Cutout; Attaches to Backer with (3) 1/4" VHB Tape to Create 11-1/16" x 8-1/4" Pocket

B Backer3mm Thick Grey Komatex

C Insert 8-1/2" x 11" x .010 Clear Lexedge

D Mount(2) 10" x 3/4" White Foam Tape Tabs

Page 101: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

X.1

X.1 Informational Window Plaque

101 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

Side View

9 1/16 "

11 5/8"

B

A

C

1/4"10 7/8"

8 5/16"

3/8"

scale: 3" = 1'-0"

A Window Plaque1/4" Thick Clear Acrylic w/ 45° Polished Full Bevels; Reverse Screened Metalic Silver M45 w/ 8-5/16" x 10-7/8" Window Cutout

B Insert8-1/2" x 11" (By Others)

C Mount(3) Tabs of 3M 4949 VHB Tape, (2) 9-1/16" Left & Right & (1) 9-3/4" Bottom to form 8-13/16" x 11-1/8" Pocket

Page 102: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

X.66

X.66 Informational Window Plaque

102 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

Side View

Sample Insert Message

6"

6"

B

A

C

1/4"

3/8" typ.

5 1/4"

5 1/4"

5 21/32"

5 7/16"

scale: 1/2" = 1"

A Window Plaque1/4" Thick Clear Acrylic w/ 45° Polished Full Bevels; Reverse Screened Metallic Silver M45 w/ 5-1/4" x 5-1/4" Window Cutout

B Insert.010 Thick Clear Gerber Lexedge; Printed Black Copy

C Mount(3) Tabs of 3M 4949 VHB Tape, (2) 6" Top & Bottom & (1) 5" Left to form 5-1/2" x 5-1/2" Pocket

Page 103: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

X.99

X.99 Informational Window Plaque

103 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

Side View

Sample Insert Message

9"

9"

3/8" typ.

1/4"

B

A

C

8 21/32"

8 7/16"

8 1/4"

8 1/4"

scale: 3/8" = 1"

A Window Plaque1/4" Thick Clear Acrylic w/ 45° Polished Full Bevels; Reverse Screened Metallic Silver M45 w/ 8-1/4" x 8-1/4" Window Cutout

B Insert.010 Thick Clear Gerber Lexedge; Printed Black Copy

C Mount(3) Tabs of 3M 4949 VHB Tape, (2) 9" Top & Bottom & (1) 7" Left to form 8-1/2" x 8-1/2" Pocket

Page 104: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

XB.99

XB.99 Informational Window Plaque w/ Backer

104 Sign DrawingsCleveland Clinic Interior Sign Standards Manual

See Elevation 8

Specifications

Side View

Sign Back

9"

9"

3/8" typ.

B

A

C

1/8"1/4"

8 1/4"

8 1/4"

scale: 3/8" = 1"

A Window Plaque1/4" Thick Clear Acrylic w/ 45° Polished Full Bevels; Reverse Screened Metallic Silver M45 w/ 8-1/4" x 8-1/4" Window Cutout; Attaches to Backer with (3) Tabs of 3M 4949 VHB Tape, (2) 9" Top & Bottom & (1) 7" Left to form 8-3/4" x 8-3/4" Pocket

B Backer3mm Thick Grey Komatex

C Insert8-7/16" High x 8-21/32" (By Others)

D Mount(5) .032" x 1 1/2" x 1/2" White Foam Tape Tabs

Page 105: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

section 4

Elevations

Elevation 1 : Large Wall Plaques ............ 1

Elevation 2 : Small Wall Plaques ............ 1

Elevation 3 : Overhead Signs ................. 1

Elevation 4 : Projected Mount Signs ....... 1

Elevation 5 : Desk Signs ....................... 1

Elevation 6 : Room Identification ............ 1

Elevation 7 : Typical Elevator Signage ..... 1

Elevation 8 : Typical Entry Signage ......... 1

Elevation 9 : Typical Stairwell Signage .... 1

Elevation 10 : Typical Donor Signage ...... 1

105Cleveland Clinic Interior Sign Standards Manual

Page 106: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

6" from corner

75" AFFto top of sign

Elevations

Scale: 1/2” = 1’-0”

Large Wall Plaques

106Cleveland Clinic Interior Sign Standards Manual

Elevation 1

Page 107: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Elevations

Scale: 1/2” = 1’-0”

107Cleveland Clinic Interior Sign Standards Manual

Elevation 2 Small Wall Plaques

Page 108: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Elevations

Scale: 1/2” = 1’-0”

108Cleveland Clinic Interior Sign Standards Manual

Elevation 3 Overhead Signs

Page 109: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Elevations

Scale: 1/2” = 1’-0”

109Cleveland Clinic Interior Sign Standards Manual

Projected Mount SignsElevation 4

Page 110: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Elevations

Scale: 1/2” = 1’-0”

110Cleveland Clinic Interior Sign Standards Manual

Desk SignageElevation 5

Page 111: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Elevations

Scale: 1/2” = 1’-0”

111Cleveland Clinic Interior Sign Standards Manual

Room IdentificationElevation 6

Page 112: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Elevations

Scale: 1/2” = 1’-0”

112Cleveland Clinic Interior Sign Standards Manual

Typical Elevator SignageElevation 7

Page 113: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Elevations

Scale: 1/2” = 1’-0”

113Cleveland Clinic Interior Sign Standards Manual

Typical Building Entry SignageElevation 8

551 E. Washington StreetChagrin Falls

URGENT CAREFamily Health CenterChagrin Falls551 E. Washington Street

Page 114: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Elevations

Scale: 1/2” = 1’-0”

114Cleveland Clinic Interior Sign Standards Manual

Outside Stairwell Inside Stairwell

Typical Stairwell SignageElevation 9

Page 115: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic

Elevations

Scale: 1/2” = 1’-0”

115Cleveland Clinic Interior Sign Standards Manual

Typical Donor SignageElevation 10

Page 116: Interior Sign Standards Manualportals.clevelandclinic.org/Portals/57/SIGN STANDARDS ManualDesign... · the hospital environment so that signage ... construction, materials, graphic