introducing sps&spuseries · 2018. 12. 19. · sps spu legend we make winters warmer...
TRANSCRIPT
-
��
THE ECONOMICAL
ALTERNATIVE FOR
HARD-TO-HEAT
SPACES:• Manufacturing Plants
• Warehouses
• Auto Dealerships
• Aircraft Hangars
• Loading Docks
• Weld Shops
• Car Washes
• Fire Stations
• Greenhouses
• Gymnasiums
• Garages
• Machine Shops
• Tennis Courts
• Swimming Pools
• Maintenance Shops
• Farm Buildings
• Truck Service Areas
• Auto Body Shops
CONVECTION HEATForced air convection heat works from the top
down, heating the air first and stratifying from theceiling downward. More heat is wasted in the
upper area of the building.
INFRARED HEATInfrared heat works from the bottom up,warming people, floors and machines first.Comfortable heat is retained in the lower
working areas of your building.
SPS & SPU SeriesINTRODUCING
Whether you need to heat your warehouse, garage, or other hard-to-heat spaces,the SunStar SPS/U Series infrared heaters provide both the fuel efficiency of radiantheat and the installation flexibility you need . . . and all at a comfortable price.
INFRARED TUBE HEATERSunStar infrared tube heaters are ideal for complete building heator spot heating needs. The best applications are those where doorsopen and close frequently and in buildings where ceiling heightsare above ten feet. The flexible SunStar infrared heating systemcan be designed to meet any commercial or industrial heatingneeds.
HEAT LIKE THE SUNSunStar infrared tube heaters heat like the sun by transferringradiant heat energy directly into the area to be heated. This energyis then absorbed by concrete floors, objects and people and is thenre-radiated to warm the surrounding area. This creates a warmcomfort zone at floor level, not at the ceiling.
FUEL SAVINGS UP TO 50%This extremely efficient method of heating can result in fuelsavings of between 30% and 50% when compared to forced airconvection heating.With the SunStar system, investment paybackaccrues not only from reduced energy costs, but from the reducedmaintenance costs, too.
Push Through (Positive Pressure)
Single Stage InputTwo Stage Input
-
SPU SERIESProvides more uniformradiant heat energydistribution. Ideal forhigh heat loss areas andspot heating.
SPS SERIESAvailable in multipleconfigurations (straight,L,Z and expandedU-configuration) withlengths up to 70 feet.Ideal for completebuilding heating.
SPS/SPU SERIES FEATURES
General Features• 8 different Btu sizes and more than 60 differentconfigurations to custom design your infraredheating system
• Single stage or two stage input controls• CSA design certified• Available in natural and propane gas• Optional decorative grille• Optional elbow and corner reflectors• Sidewall or through the roof venting• Vented or indirect vented operation
Push Through Positive PressureSystem• Products of combustion are pushed through thecombustion chamber
• Tube Integrity Safety System (TISS)• No draft hoods, totally enclosed combustionchamber
• Blower motor totally enclosed in the burnerbox. Ideal for applications where minimalnoise ( less than 50 dB) is desired
• Heavy duty permanently lubricated and ballbearing motor for maintenance-free operation
• Pre-purge and Post purge functions• Diaphragm air switch for proof of ventingbefore gas flow and ignition
Burner System• Heavy duty cast iron burner• Reliable direct spark ignition system and 100%gas shut-off safety control
• Burner inspection sight glass• Step-opening redundant combination gas valvefor quiet ignition and added safety
• Inside or outside air for combustion• Up to 25 ft. outside combustion air capability• Standard outside combustion air intake collar• Diagnostic Monitoring Light System• Line voltage or 24V thermostat connection
Radiant Emitter Tube System• 4” O. D. heat treated aluminized steel or alumi-therm steel combustion chamber (10’ length)
• Standard highly emissive radiant tubes (10’ lengths)• Optional heat treated aluminized steel radianttubes (Tough Guy Option)
• 5 year limited warranty on all tubes• Suitable for horizontal or angle mounting up to 45˚with optional tube support hanger bracket
• Up to 25 feet sidewall vent capability
Reflector System• Highly efficient aluminum reflectors• Individual reflectors can be rotated up to 45˚ todirect heat where needed
• Optional end, corner, U-bend and side exten-sion reflectors
GASTYPENatural
Propane
BURNERPRESSURE3.5”W.C.
10”W.C.
MIN.5”W.C.
11”W.C.
MAX.14”W.C.
14”W.C.
VOLTAGE120VAC
60 Hz
AMPS
1.8
IGNITIONTYPEDirect
Spark
SUPPLY PRESSURE
NOTE: For installations higher than 2000 ft. above sea level, call SunStar for recommended derating of heaters.
FLUECONNECTION
4” Round
FRESH AIRCONNECTION
4” Round
-
SunStar’s newly developed Tube Integrity Safety System*(TISS) provides peace of mind. It may never be needed,but in the unlikely event of a tube failure, you will behappy that you have a TISS. It is simple. A low voltagecircuit continuously monitors the clearance abovethe reflector for excessive overheat and tubeintegrity compromise. You may never knowit is there, but on a positive pressuretube heater it is nice to knowyou have the TISS.
Low VoltageCircuit Control
SpringRetainerClamp
Spring
TUBE INTEGRITY SAFETY SYSTEM (TISS™)
MODEL
SPS - BOTTOM VIEW SPS - END VIEW SPU - BOTTOM VIEW SPU - END VIEW
TOTAL TUBE OVERALLLENGTH (FT) DIMENSION “L”(FT) TOTAL TUBE OVERALL
LENGTH (FT) DIMENSION “L” (FT)MODELSPS (40)SPS (40, 50, 75)SPS (50, 75,100,125)SPS (50, 75, 100, 125, 150)SPS (100, 125, 150, 175, 200)SPS (125, 150,175,200)SPS (175, 200)
10’20’30’40’50’60’70’
11’ 2”21’ 2”31’ 2”41’ 2”51’ 2”61’ 2”71’ 2”
SPU (40, 50, 75)SPU (50, 75,100, 125)SPU (50, 75, 100, 125, 150)SPU (100, 125, 150, 175, 200)SPU (125, 150,175, 200)SPU (175, 200)
20’30’40’50’60’70’
12’ 5”17’ 5”22’ 5”27’ 5”32’ 5”37’ 5”
13”
6”
18”
31”
6”
90˚ ELBOW
SPS OPTIONS
CORNER REFLECTOR
Burner Box Dimensions(10” W x 14” L x 14” H)
Top ofReflector
10’ LongAluminumWire &Sleeve Assembly
TECHNICAL SPECIFICATIONS
MODEL
SPS/U 40 40,000 40,000 25,000
SPS/U 50 50,000 50,000 30,000
SPS/U 75 75,000 75,000 50,000
SPS/U 100 100,000 100,000 65,000
TOTAL EMITTER TUBE LENGTH*10 FT** 20 FT 30 FT 40 FT
SINGLESTAGEBTU/HRINPUT
Btu/hrHigh Input
Btu/hrLow Input
TWO STAGE
• •••
•••
•••
MODEL
SPS/U 125 125,000 125,000 80,000
SPS/U 150 150,000 150,000 100,000
SPS/U 175 175,000 175,000 110,000
SPS/U 200 200,000 200,000 125,000
TOTAL EMITTER TUBE LENGTH*30 FT 40 FT 50 FT 60 FT 70 FT
SINGLESTAGEBTU/HRINPUT
Btu/hrHigh Input
Btu/hrLow Input
TWO STAGE
• ••
••••
••••
••
CONTROL SUFFIX
N5 / L5N7 / L7
TYPE OF GAS
Natural / PropaneNatural / Propane
CONTROL OPTION DESCRIPTION
Single Stage Gas Valve - Single Stage Input
Two Stage Gas Valve - Two Stage Input - High/Low Fire
DIMENSIONS
SPS & SPU BURNER BOX
* Model number is based on Btu/hr input (e.g., 100,000 Btu/hr), total emitter length (e.g., 40 feet) and gas type (e.g., natural gas single stage input). For example, the modelnumber for a natural gas single stage straight tube heater would be SPS100-40-N5 and for a U-tube heater would be SPU100-40-N5. ** Available only on SPS models.
Tough Guy Option: All aluminized steel radiant tubesFor Tough Guy option the model number would be SPS100-40-TG-N5. Note: for Carwashes, Dairy Barns, Greenhouses, Swimming Pools, Waste WaterTreatment Plants, and other high humidity / corrosive environments, Tough Guy with all aluminized tubes is recommended.
* US & worldwide Patents Pending
-
TYPICAL SPS/SPU SERIES LAYOUTS
MINIMUM RECOMMENDED MOUNTING HEIGHTS
MINIMUM CLEARANCES TO COMBUSTIBLES
Over 60 different layout configurations are available. 40 ft. system layout is shown. For complete layout possibilities, refer to Installation and Operation Instructions.
This chart is intended as a guide only and heaters may be mounted at various heights and angles. Please consult your local SunStarRepresentative or Distributor for a detailed analysis of your particular infrared heating requirements.
NOTES: Since straight tubes are always hotter at the burner end than at the exhaust end, always observe the minimumrecommended mounting heights shown on the specification sheet for greatest human comfort. Use SPU series instead of SPS seriesfor spot heating applications.
* When used indirect vented, clearance to CEILING must be: 12” for SPS/U (50-75) and 18” for SPS/U (100-200).** Maximum clearance below reduces by 50% once you are 25ft. downstream from the burner box. Call SunStarif reduced clearances are required
COMBUSTION AIR VENTILATIONCombustion air and venting requirements for all gas-fired heating equipment must be provided per National Fuel Gas Code NFPA 54 or the authority havingjurisdiction over the installation. In contaminated atmospheres or high humidity areas, optional outside air for combustion can be supplied. Heaters can becommon vented, direct vented or indirect vented. Refer to Installation and Operation Instructions for further information. A vented installation must be ventedto the outside of the building with a flue pipe. An indirect vented installation requires a minimum ventilation flow of 4 CFM per 1000 Btu/hr of total installedheater capacity on natural gas by either gravity or power ventilation (4.18 CFM per 1000 Btu/hr on propane). For indirect vented applications, building exhaustopening must be located above the level of the heaters and inlet air openings must be located below the level of the heaters.
FOR YOUR SAFETYOPERATE SUNSTAR GAS INFRARED HEATERS WITH PROPER CARE AND OBSERVE ALL SAFETY PRECAUTIONS. Installation and service mustbe performed by a licensed contractor. The installation must conform with local codes. In the absence of local codes, the installation must conform with theNational Fuel Gas Code ANSI Z223.1 (latest edition also known as NFPA 54) or CGA B149 installation codes (latest edition). These codes are available fromANSI, 1430 Broadway, New York, NY 10018, The National Fire Protection Association, Inc., Batterymarch Park, Quincy, MA 02269 or the Canadian GasAssociation, 55 Scarsdale Road, Toronto, Ontario M3B 2R3 Canada.
Burner Box
Flue Termination
10 Ft. Body Section
180˚ U-Bend
90˚ Elbow
40 Ft.System
40 Ft.System
MODELSPS/U 40SPS/U 50SPS/U 75SPS/U 100
HEIGHT ATHORIZONTAL
10 Feet11 Feet13 Feet14 Feet
HEIGHT AT45˚ ANGLE
9 Feet10 Feet12 Feet13 Feet
MODELSPS/U 125SPS/U 150SPS/U 175SPS/U 200
HEIGHT ATHORIZONTAL
14 Feet15 Feet16 Feet18 Feet
HEIGHT AT45˚ ANGLE13 Feet14 Feet15 Feet16 Feet
MODEL NO.
SPS/U 40SPS/U 50SPS/U 75SPS/U 100SPS/U 125SPS/U 150SPS/U 175SPS/U 200
SIDE
22”22”22”28”28”34”38”42”
CEILING
6”6”6”6”6”6”6”6”
BELOW
52”56”60”70”76”81”86”93”
END
15”15”15”15”20”20”20”20”
(45˚)FRONT
40”48”52”58”66”70”75”80”
(45˚)REAR
12”12”12”12”12”12”12”12”
SPS SPU LEGEND
We Make Winters Warmer
306 West Tremont AvenueP.O. Box 36271Charlotte, North Carolina 28236Telephone: (Toll Free): 1-888-778-6782Telephone: (704) 372-3486Fax: (704) 332-5843Email: [email protected]
SunStar Heating Products, Inc. strives to improve quality and performance on a continuing basis and reserves the right to change specifications and material without notice.
©Copyright 2008, SunStar Heating Products, Inc. 100810M Form No. R103
DISTRIBUTED BY