introduction of sspc pa2 - kepic : 방문을 환영합니다.1 목 차 sspc sspc pa2-1996 sspc...

27
2016 KEPIC - WEEK Introduction of SSPC PA2 (2012 version) 2016. 09 한국전력기술㈜ 도장 스페셜리스트 이철우

Upload: buicong

Post on 01-Apr-2018

360 views

Category:

Documents


17 download

TRANSCRIPT

Page 1: Introduction of SSPC PA2 - KEPIC : 방문을 환영합니다.1 목 차 SSPC SSPC PA2-1996 SSPC PA2-2012 Calibration, Verification, Adjustment Procedure for Determining Conformance

2016 KEPIC - WEEK

Introduction of SSPC PA2 (2012 version)

2016. 09

한국전력기술㈜

도장 스페셜리스트 이철우

Page 2: Introduction of SSPC PA2 - KEPIC : 방문을 환영합니다.1 목 차 SSPC SSPC PA2-1996 SSPC PA2-2012 Calibration, Verification, Adjustment Procedure for Determining Conformance

1

목 차

SSPC

SSPC PA2-1996

SSPC PA2-2012

Calibration, Verification, Adjustment

Procedure for Determining Conformance to DFT

Things To Do

Page 3: Introduction of SSPC PA2 - KEPIC : 방문을 환영합니다.1 목 차 SSPC SSPC PA2-1996 SSPC PA2-2012 Calibration, Verification, Adjustment Procedure for Determining Conformance

2

SSPC

SSPC(Structural Steel Painting Council)

SSPC International(The Society of Protective

Coatings International)

Page 4: Introduction of SSPC PA2 - KEPIC : 방문을 환영합니다.1 목 차 SSPC SSPC PA2-1996 SSPC PA2-2012 Calibration, Verification, Adjustment Procedure for Determining Conformance

3

SSPC

SSPC-PA2(1996, June 1st):

Paint Application Standard No.2, Measurement of

Dry Coating Thickness with Magnetic Gages

SSPC-PA2(2012, May 1st):

Paint Application Standard No.2, Procedure for

Determining Conformance to Dry Coating Thickness

Requirements

SSPC-PA2(2015):

Page 5: Introduction of SSPC PA2 - KEPIC : 방문을 환영합니다.1 목 차 SSPC SSPC PA2-1996 SSPC PA2-2012 Calibration, Verification, Adjustment Procedure for Determining Conformance

4

SSPC PA2 - 1996

Type 1: Magnetic Gage

Type 1A: Pencil Type

Type 1B: Banana Gage, 영구자석 사용

Page 6: Introduction of SSPC PA2 - KEPIC : 방문을 환영합니다.1 목 차 SSPC SSPC PA2-1996 SSPC PA2-2012 Calibration, Verification, Adjustment Procedure for Determining Conformance

5

SSPC PA2 - 1996

Type 2: Electro Magnetic Type, 전기를 이용

Page 7: Introduction of SSPC PA2 - KEPIC : 방문을 환영합니다.1 목 차 SSPC SSPC PA2-1996 SSPC PA2-2012 Calibration, Verification, Adjustment Procedure for Determining Conformance

6

SSPC PA2 - 1996

측정개소(그림 SSPC PA2에서 발췌)

SSPC PA2 그림 인용

Page 8: Introduction of SSPC PA2 - KEPIC : 방문을 환영합니다.1 목 차 SSPC SSPC PA2-1996 SSPC PA2-2012 Calibration, Verification, Adjustment Procedure for Determining Conformance

7

SSPC PA2 - 1996

도막두께 측정 개소

100 ft2(10 m2) 미만의 면적: 5.1항

1 spot = 최소 3 gage 리딩

Spot DFT: The average of the acceptable gage reading

5 spot

최소 15개의 게이지 리딩 필요

300 ft2(30 m2) 미만의 면적: 5.1.1항

Each 100 ft2(10 m2) 면적을 측정

최소 15 X 3 = 45개소

Page 9: Introduction of SSPC PA2 - KEPIC : 방문을 환영합니다.1 목 차 SSPC SSPC PA2-1996 SSPC PA2-2012 Calibration, Verification, Adjustment Procedure for Determining Conformance

8

SSPC PA2 - 1996

도막두께 측정 개소

300 ft2(30 m2) ~1000 ft2(100 m2) 미만: 5.1.2항

3개소의 100 ft2(10 m2) 면적을 측정

최소 15 X 3 = 45개소

1000 ft2(100 m2) 초과: 5.1.3항

임의로 선정한 처음 1000 ft2(100 m2) 면적을 5.1.2항에 따라

측정

추가되는 1000 ft2(100 m2) 의 도막두께 측정은 임의로 선정한

100 ft2(10 m2) 을 측정하여 검사

Page 10: Introduction of SSPC PA2 - KEPIC : 방문을 환영합니다.1 목 차 SSPC SSPC PA2-1996 SSPC PA2-2012 Calibration, Verification, Adjustment Procedure for Determining Conformance

9

SSPC PA2 - 2012

SSPC PA2-2012 Version의 주요 변경 내용:

불일치 부위를 확인하기 위하여 8개의 방사형

방향으로 5 ft 간격으로 spot measurements 를

측정한다(8.2.4.1항)

각각의 spot measuremen는 사업시방서 요건에

일치해야 한다

한 방향에서 연속으로 2회의 도막두께가 일치하면

측정을 중단한다.

불일치 부위를 문서화한다.

Page 11: Introduction of SSPC PA2 - KEPIC : 방문을 환영합니다.1 목 차 SSPC SSPC PA2-1996 SSPC PA2-2012 Calibration, Verification, Adjustment Procedure for Determining Conformance

10

SSPC PA2 - 2012

ASTM D7091의 도막두께 측정기 사용 시의 도막두께

일치성 확인(Determining Conformance)을 위한 절차를

기술하고 있음

ASTM D7091-2013, Standard Practice for

Nondestructive Measurement of Dry Film Thickness of

Nonmagnetic Coatings Applied to Ferrous Metals and

Nonmagnetic, Nonconductive Coating Applied to Non-

Ferrous Metals

도막결함조사를 위한 도막두께 측정의 빈도에 사용되지

않음

Page 12: Introduction of SSPC PA2 - KEPIC : 방문을 환영합니다.1 목 차 SSPC SSPC PA2-1996 SSPC PA2-2012 Calibration, Verification, Adjustment Procedure for Determining Conformance

11

SSPC PA2 - 2012

Non-mandatory appendices

Appendix 1: Numerical Example of Average Thickness

Measurement

Appendix 2: Methods for Measuring Dry Film Thickness on

Steel Beams(Girders)

Appendix 3: Methods for Measuring Dry Film Thickness for a

Laydown of Beams, Structural Steel, and Miscellaneous Parts

after Shop Coating

Appendix 4: Methods for Measuring Dry Film Thickness on

Coated Steel Test Panels

Appendix 5: Methods for Measuring Dry Film Thickness on Thin

Coatings on Coated Steel Test Panels that Have Been Abrasive

Blast Cleaned

Page 13: Introduction of SSPC PA2 - KEPIC : 방문을 환영합니다.1 목 차 SSPC SSPC PA2-1996 SSPC PA2-2012 Calibration, Verification, Adjustment Procedure for Determining Conformance

12

SSPC PA2 - 2012

Non-mandatory appendices

Appendix 6: Method for Measuring Dry Film Thickness of

Coatings on Edges

Appendix 7: Methods for Measuring Dry Film Thickness on

Steel Pipe Exterior

Appendix 8: Example of the Adjustment of Type 2 Gages Using

Shimes

Page 14: Introduction of SSPC PA2 - KEPIC : 방문을 환영합니다.1 목 차 SSPC SSPC PA2-1996 SSPC PA2-2012 Calibration, Verification, Adjustment Procedure for Determining Conformance

13

SSPC PA2 - 2012

Thermal spray coating에는 적용하지 않음:

SSPC-CS23.00/AWS C2.23N/NACE No.12:

Specification of Thermal Spray Coatings(metallizing) of

aluminum, Zinc, and Their Alloys and Composites for the

Corrosion Protection of Steel

Page 15: Introduction of SSPC PA2 - KEPIC : 방문을 환영합니다.1 목 차 SSPC SSPC PA2-1996 SSPC PA2-2012 Calibration, Verification, Adjustment Procedure for Determining Conformance

14

SSPC PA2 - 2012

Gage Reading: A single instrument reading

Spot Reading

The average of the acceptable 3 gage reading is the

spot measurement.

At least three gage reading’s average

1.5 in.(4 cm) 내에서 측정: 시편의 크기 고려

Any unusually high or low gage readings are

discarded

Area measurement

5개의 spot measurement의 평균

Each 100 ft2 (10 m2)

Page 16: Introduction of SSPC PA2 - KEPIC : 방문을 환영합니다.1 목 차 SSPC SSPC PA2-1996 SSPC PA2-2012 Calibration, Verification, Adjustment Procedure for Determining Conformance

15

Calibration/Verification/Adjustment

ASTM D7091

정확한 도막두께 측정을 위한 단계를 기술

각 스텝은 도막두께 측정 전에 완료

Calibration(검교정)

게이지 제작자 또는 시험소에서 수행

표준 검교정 주기는 없음: 보통 1년

Traceability: Nation metrology Institute(국가 도량형

기관) 요구 한국 예: KRISS(한국표준과학연구원)

원자력: International Laboratory Accreditation Cooperation (ILAC)

Mutual Recognition Arrangement(MRA), NRC RIS 2016-01, 안전성

관련 항목

Page 17: Introduction of SSPC PA2 - KEPIC : 방문을 환영합니다.1 목 차 SSPC SSPC PA2-1996 SSPC PA2-2012 Calibration, Verification, Adjustment Procedure for Determining Conformance

16

Calibration/Verification/Adjustment

Verification

검교정의 정확도(Accuracy) 확인

Gage accuracy shall be verified at a minimum of the

beginning and end of each work shit according to the

procedures described in ASTM D7091

기기를 떨어뜨렸을 때, 또는 하나의 작업기간에

오차가 너무 큰 경우 등(절차서에서 확정)

ASTM D7091는 기기의 다양성으로 제작자 매뉴얼에

따라 수행하는 것으로 기술

기록: 게이지 시리얼 번호, reference standard used,

stated thk. of the reference standard, measured thk.

Method used to verify gage accuracy

Page 18: Introduction of SSPC PA2 - KEPIC : 방문을 환영합니다.1 목 차 SSPC SSPC PA2-1996 SSPC PA2-2012 Calibration, Verification, Adjustment Procedure for Determining Conformance

17

Calibration/Verification/Adjustment

Adjust(조정)

Manufacturer’s instruction using one of the methods

described in ASTM D7091

또는 Appendix 8

Single point adjustment

Two point adjustment

Smooth surface adjustment

조정 작업 후에 8항에 따라서 spot의 도막두께를

측정

Page 19: Introduction of SSPC PA2 - KEPIC : 방문을 환영합니다.1 목 차 SSPC SSPC PA2-1996 SSPC PA2-2012 Calibration, Verification, Adjustment Procedure for Determining Conformance

18

Calibration/Verification/Adjustment

Accuracy(정확도) Vs Precision(정밀도)

Accuracy(정확도)

How close a particular measurements is to the correct value.

Precision(정밀도)

Consistency of repeated measure.

The best measurements are accurate and

precision.

Page 20: Introduction of SSPC PA2 - KEPIC : 방문을 환영합니다.1 목 차 SSPC SSPC PA2-1996 SSPC PA2-2012 Calibration, Verification, Adjustment Procedure for Determining Conformance

19

도막두께 확인을 위한 절차

불일치 지역 판정: 8.2.4항

모든 100 ft2(10 m2) 면적의 도막두께가 계약문서에서

규정된 도막두께와 상이할 때 불일치 지역을 확인해야

5 ft 간격으로 spot DFT reading을 확인

8개 방향으로 외부로 방사하는 형태

같은 방향에서 연속적으로 두 번의 spot

measurement(5ft 간격)가 계약문서의 최소/최대 두께

내에 있을 때 합격(single spot measurement로 끝냄)

No allowance is made for variant spot measurements

as is the practice when determining the area DFT.

Page 21: Introduction of SSPC PA2 - KEPIC : 방문을 환영합니다.1 목 차 SSPC SSPC PA2-1996 SSPC PA2-2012 Calibration, Verification, Adjustment Procedure for Determining Conformance

20

도막두께 확인을 위한 절차

불일치 지역 판정: 8.2.4항

SSPC PA2 그림 인용

Page 22: Introduction of SSPC PA2 - KEPIC : 방문을 환영합니다.1 목 차 SSPC SSPC PA2-1996 SSPC PA2-2012 Calibration, Verification, Adjustment Procedure for Determining Conformance

21

도막두께 확인을 위한 절차

불일치 지역 판정: 8.2.4항

불일치 지역 표시

Removal chalk 또는 기타 규정된 마킹 자재 사용:

시방서에 표기 필요(절차서에서 사업주에 승인)

Non-compliant area: Non-compliant spot 1.5 ft(1.5 m)

보수 후에 재검사

8.2.5항

App.2~App.7: 옵션(절차서에 적용 여부에 대한 기술이 필요)

Area size, frequency of spot measurement

Page 23: Introduction of SSPC PA2 - KEPIC : 방문을 환영합니다.1 목 차 SSPC SSPC PA2-1996 SSPC PA2-2012 Calibration, Verification, Adjustment Procedure for Determining Conformance

22

도막두께 확인을 위한 절차

Page 24: Introduction of SSPC PA2 - KEPIC : 방문을 환영합니다.1 목 차 SSPC SSPC PA2-1996 SSPC PA2-2012 Calibration, Verification, Adjustment Procedure for Determining Conformance

23

도막두께 확인을 위한 절차

일반적인 시방서 layer 및 system의 최소/최대치 규정

없는 경우 +/- 20%

Level 1: Most restrictive

Level 5: Least restrictive

시방서 작성자(specifier)는 특정 사업에서의

도막두께 관리 등급을 제공해야 한다(시방서 표기

필요)

만약 별도의 표기가 없을 경우에는 SSPC는 Level

3로 default한다고 기술

Page 25: Introduction of SSPC PA2 - KEPIC : 방문을 환영합니다.1 목 차 SSPC SSPC PA2-1996 SSPC PA2-2012 Calibration, Verification, Adjustment Procedure for Determining Conformance

24

도막두께 확인을 위한 절차

SSPC PA2 그림 인용

Page 26: Introduction of SSPC PA2 - KEPIC : 방문을 환영합니다.1 목 차 SSPC SSPC PA2-1996 SSPC PA2-2012 Calibration, Verification, Adjustment Procedure for Determining Conformance

25

Things to Do

신규 발행된 기술기준의 사업 적용 시 도장검사 및

도장시공 공정에 영향을 줄 수 있으므로 적용범위에

대하여 사업주와 협의 필요

적용범위에 대한 사업주와의 협의 결과를 시방서에

반영

현장발행 도막두께 불일치 보고서 확인 시 도막두께

검측의 정확성 및 절차의 적합성을 확인

Appendix의 사업 적용성 확인 후 반영

Calibration, Verification, Adjustment에 대한

검사기기 업체별 사용 매뉴얼 숙지 필요