20
Introduction to Compliance EMC Testing Mr Xue Yu Hao Assistant Director, Systems Detect it early: EMI troubleshooting techniques and corrective action 18 May 2018, Friday Rohde & Schwarz Regional Learning Centre COMPANY RESTRICTED

Upload: others

Post on 13-Apr-2020

20 views

Category:

Documents


0 download

TRANSCRIPT

Introduction to Compliance EMC TestingMr Xue Yu Hao

Assistant Director, Systems

Detect it early: EMI troubleshooting

techniques and corrective action

18 May 2018, Friday Rohde & Schwarz Regional Learning Centre

COMPANY RESTRICTED

My Profile

ı Portfolio

Yuhao Xue

Technical Sales for EMC & RF

System Group

Rohde & Schwarz Asia Ptd Ltd

9 Changi Business Park Vista

#01-01, Singapore 48641

DID: +65 6307 0145

[email protected]

www.rohde-Schwarz.com

Yuhao Xue

Assistant Director

Systems

RF & Conformance SystemsEMC Systems ADAS & Antenna meas. Systems

COMPANY RESTRICTED

Compliance EMC Testing: Measuring EquipmentMeasuring receivers

ESL ESRP ESR ESW

Frequency 9 kHz to 3, 6 GHz 9 kHz to 3.6, 7 GHz 10 Hz to 3.6, 7, 26.5 GHz 2 Hz to 8, 26.5, 44 GHz

Differentiation Lowest cost dedicated EMI receiver

Closest performance to compliance receiver

+ TDEMI Highest technical specification compliance receiver

Configuration No additional requirement No additional requirement No additional requirement No additional requirement

Messaging Compact, cost-effective test receiver covering almost all commercial EMI standards

Pre-compliance measurements – fast and straightforward

Maximum precision, standard-compliant EMI measurements at unparalleled measurement speed

High dynamic range, standard-compliant EMI measurements with maximum measurement speed.

Compliance up to 40 GHz

Compliance TestingPre-Compliance

COMPANY RESTRICTED

Compliance EMC Testing: Measuring EquipmentTransducers

Footer: >Insert >Header & Footer 4

Antenna – electric radiated emission

ISN - Conducted voltage

Antenna – magnetic radiated emission

Current probe – conducted current

Artificial Network – Conducted voltage

Absorbing clamp – disturbance power

COMPANY RESTRICTED

Compliance EMC Testing: Test Sites

ı Open Area Test Site (OATS)

Outdoor environment

ı Semi-Anechoic Chamber SAC

Shielded enclosure covered

with absorber, except for floor

30 M to 1 GHz

ı Fully-Anechoic Chamber FAC

Shielded enclosure covered

with absorber

1 G to 18 GHz

COMPANY RESTRICTED

RSASIA EMC CHAMBER

Control Room- 7800mm x 4900mm x 3000mm

- EMI / EMS Test System

- High performance Amplifier

Semi Anechoic Chamber- 9400mm x 5500mm x 5700mm

- EMI / EMS Test

- Antenna Mast, Turn Device, Test Table

Shield Room- 3100mm x 4900mm x 5550mm

- EMS Test

- Upgradable to Reverberation chamber

COMPANY RESTRICTED

RSASIA EMC CHAMBER – Facility

Semi Anechoic Chamber

Dimension 9400mm x 5500mm x 5700mm

Test Scope Radiated Emission

Radiated Susceptibility

Conducted Emission

Conducted Susceptibility

Over-The-Air antenna test

Equipment

&

Features

1m to 4m Tilting Antenna Mast

360º Turn Table (Azimuth)

360º Turn Device (Elevation)

Optional Absorbers for FAC

Monitoring Camera (fixed & Mobile)

Ground connectable wall side

Rohacell & Conductive test table

Lightings for EMC testing

Sliding main door

COMPANY RESTRICTED

RSASIA EMC CHAMBER – Facility

Shield Room

Dimension 3100mm x 4900mm x 5550mm

Test Scope Conducted Emission

Conducted Susceptibility

Shielding Effectiveness test

Equipment

&

Features

CISPR test table

Grounding wall side

Upgradable to Reverberation chamber

COMPANY RESTRICTED

RSASIA EMC CHAMBER – Facility

Control Room

Dimension 7800mm x 4900mm x 3000mm

Equipment

&

Features

TS9976 EMI system

TS9982 EMS SYSTEM

BBA150 Amplifier (9KHz – 6GHz)

R&S Latest Test Receiver ESW44

CMW500 Radio Communication Tester

R&S EMC32 test S/W

R&S Elektra test S/W

R&S AdVISE EUT monitoring system

DST200 Diagnostic Chamber

Shielding Effectiveness test via SR

External Amplifier port

COMPANY RESTRICTED

Performing radiated immunity measurements

According IEC 61000-4-3 / EN 610000-4-3

26MHz – 18GHz / 1.5m x 1.5m / 75% within 0 to +6 dB

Performing radiated emissions measurements above 1 GHzAccording CISPR 16-1-4 / EN 55016-1-4

1GHz – 18GHz / ≤ 5.5dB

Performing radiated emissions measurements below 1 GHz

According CISPR 16-1-14 / ANSI C63.4

30MHz - 1GHz / Deviation ±3.5dB

Shielding from outside signal

According MIL285 / IEEE299

Attenuation 80dB ~ 110dB

RSASIA EMC CHAMBER – Validation

Shielding

Performance

Normalized

Site

Attenuation

Field

Uniformity

Site

VSWR

COMPANY RESTRICTED

RSASIA EMC CHAMBER – Test Coverage

CISPR StandardCISPR 11

CISPR 22

CISPR 24

CISPR 25

EN StandardEN 50498

EN 50022

EN 61000-4-3

EN 61000-4-6

FCC StandardFCC part 15

3GPP Standard

CTIA Standard

MIL StandardRE 102

RE 103

RS 103

CE 101

COMPANY RESTRICTED

RSASIA EMC CHAMBER – Usage

Testing

&

Studying

R&D – product EMC test for CE, FCC, IEC certification

System Engineering – Case study for new standard and product

<EN 50498 testing> <CISPR 22 RE testing>

COMPANY RESTRICTED

Customer

FATFactory Acceptance Test for customer

Validation system performance

RSASIA EMC CHAMBER – Usage

COMPANY RESTRICTED

Demo

&

Show case

Demonstration for new R&S product

Visitors from Customer, Education center, Government and etc.

RSASIA EMC CHAMBER – Usage

<Students from University> <ESW 44 demonstration>

COMPANY RESTRICTED

TrainingInternal / external training course

for EMC, EMC testing and R&S system

RSASIA EMC CHAMBER – Usage

<EMC Training> <Internal training>

COMPANY RESTRICTED

RSASIA EMC CHAMBER – EMI Testı Sample system for Radiated Emission test

EMC Chamber System Training

EMC32

Test Turn TableHorizontal & Vertical

Polarisations tested

AntennaEMI Test Receiver

COMPANY RESTRICTED

RSASIA EMC CHAMBER – TS9976 EMI system

EMC Chamber System Training

EMC32

Software

ESW44

Test Receiver

OSP120

Switching Unit

Ant. MASTNCD

Positioner ControllerTurn TableTurn Device

RF CABLE

LAN

Fiber Optic

HL562E

Ant. (30MHz to 6GHz)HF907

Ant. (800MHz to 18GHz)

HK116

Ant. (20MHz to 300MHz)VUBA 9117

Ant. (150MHz to 1GHz)

HFH2-Z6

Ant. (9kHz to 30MHz)

ENV216

2-Line V-NetworkENV432

4-Line V-Network

ESH3-Z6

V-Network

ENY81-CA6

Coupling Network

COMPANY RESTRICTED

RSASIA EMC CHAMBER – EMS Testı Sample system for Radiated Susceptibility test

EMC Chamber System Training

<SAC> <CR>

COMPANY RESTRICTED

RSASIA EMC CHAMBER – TS9982 EMS SYSTEM

EMC32

Software

OSP120

Switching Unit

RF CABLE

LAN

GPIB

BBA150

Band A

BBA150

Band B/C

BBA150

Band D/E

STLP9149

Ant. (0.7GHz to 9GHz)

SMB100A

Signal GeneratorNRP2 & NRP-Z91

Power Meter

FL7006

Field Probe kit

F-120-9A

Current Injection Probes

HL046E

Ant. (80 MHz to 3 GHz)

COMPANY RESTRICTED

End of presentationThank you for your attention

COMPANY RESTRICTED