Workshop Chamonix, Dec, 12, 2007 Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report - P. Forck, W. Kaufmann, P. Kowina, P. Moritz, U. Ra GSI

Upload: benedict-cooke

Post on 02-Jan-2016

17 views

Category:

Documents


0 download

DESCRIPTION

Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -. P. Forck, W. Kaufmann, P. Kowina, P. Moritz, U. Rauch GSI. Outline. Brief introduction to accelerators at GSI and motivation Classical measuring method Short crosslink: direct diode detection - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

Workshop Chamonix, Dec, 12, 2007

Investigations on BaseBand tune measurements using direct

digitized BPM signal- progress report -

Investigations on BaseBand tune measurements using direct

digitized BPM signal- progress report -

P. Forck, W. Kaufmann, P. Kowina, P. Moritz, U. RauchGSI

Page 2: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 2Udo Rauch

OutlineOutline

Brief introduction to accelerators at GSI and motivation

Classical measuring method

Short crosslink: direct diode detection

Libera position data as possible data source

Summary and outlook.

Page 3: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 3Udo Rauch

SIS-18 synchrotron at GSISIS-18 synchrotron at GSI

Important parameters of SIS-18:- Circumference 216 m- Inj. type Multiturn- Energy range 11 MeV → 2 GeV- Acc.RF 0.8 → 5 MHz- Acc. harmonic 4 (no. of bunches)- Bunching factor 0.6 → 0.2- Ramp duration 0.3 → 1.5 s- Typical tune h/v 4.319 3.29- Tune meas. sys. Exciter + BPM

Schottky- Ion range (Z) 1 → 92 (p to U)- Design beams 2 x 10¹¹ U 28+

1 x 10¹³ p

Page 4: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 4Udo Rauch

SIS-18 synchrotron at GSISIS-18 synchrotron at GSI

Important parameters of SIS-18:- Circumference 216 m- Inj. type Multiturn- Energy range 11 MeV → 2 GeV- Acc.RF 0.8 → 5 MHz- Acc. harmonic 4 (no. of bunches)- Bunching factor 0.6 → 0.2- Ramp duration 0.3 → 1.5 s- Typical tune h/v 4.319 3.29- Tune meas. sys. Exciter + BPM

Schottky- Ion range (Z) 1 → 92 (p to U)- Design beams 2 x 10¹¹ U 28+

1 x 10¹³ p

Page 5: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 5Udo Rauch

MotivationMotivation

Up to now no tune tracking system yet available at GSI Necessity arises due to upgrade of existing accelerator for higher

beam intensities and/for future accelerator(s) in FAIR project Target

(PLL) tune tracking BaseBand – q Single bunch separation

Two platforms possible for baseband: 3D and direct digitization Earlier recorded data (FFTransformed) show rich amount of not

understood frequency spikes in spectra also in region of baseband (without any beam excitation). Thus: starting with an easy and safe method => noise excitation of sidebands

Page 6: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 6Udo Rauch

amplifier

amplifier

BPM

hybr

id

BEAM

Exciter

RSA

180 splitter

25 W

50dB

25 W

50dB

digital noise

generator

Digital Random Noise GeneratorDigital Random Noise Generator

RF clock signal

Page 7: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 7Udo Rauch

amplifier

amplifier

BPM

hybr

id

BEAM

Exciter

RSA

180 splitter

25 W

50dB

25 W

50dB

digital noise

generator

Digital Random Noise GeneratorDigital Random Noise Generator

RF clock signal

Page 8: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 8Udo Rauch

amplifier

amplifier

BPM

hybr

id

BEAM

Exciter

180 splitter

25 W

50dB

25 W

50dB

digital noise

generator

RSA

Digital Random Noise GeneratorDigital Random Noise Generator

RF clock signal

Page 9: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 9Udo Rauch

Digital Random Noise GeneratorDigital Random Noise Generator

1 MHz carrier frequencyNumber of harmonics : 1q is set to 0.3 with a dq of 0.01

Frequency sweep (pseudo-RF as input)Number of harmonics : 4q is set to 0.3 with a dq of 0.03

Amplitude and width of excitation can be modified also remote controlled

Page 10: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 10Udo Rauch

Classical approach: one harmonic onlyClassical approach: one harmonic only

Argon 18+100 ms coolingRamp to 2 GeV in 700 ms

t = 250m

s

11 MeV

Page 11: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 11Udo Rauch

Classical approach: one harmonic onlyClassical approach: one harmonic only

Argon 18+100 ms coolingRamp to 2 GeV in 700 ms

t = 250m

s

11 MeV

- Only one harmonic- Signal to noise improvable

Page 12: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 12Udo Rauch

The direct diode detection (principles)The direct diode detection (principles)

Design and realisation by Marek Gasior et al (CERN)

Decay constant: R x C = tau ~ 100 x T

Gain comparedto classical system

G_d = Signal to noise(3d)

Signal to noise (class)

Page 13: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 13Udo Rauch

The direct diode detection (principles)The direct diode detection (principles)

Design and realisation by Marek Gasior et al (CERN)

Decay constant: R x C = tau ~ 100 x T

Gain comparedto classical system

G_d = Signal to noise(3d)

Signal to noise (class)

Page 14: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 14Udo Rauch

The direct diode detectionThe direct diode detection

Signal difference 2V (offset α)Betatron oscillation relative amplitude β = 0,05Simulated tune value q = 0,319Filter time constant tau = 50T ( = 200Tb)

CircuitryPrinciplesBy MarekGasior(CERN)

Page 15: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 15Udo Rauch

The direct diode detection (results)The direct diode detection (results)

SIS - 18

1000 kHz

250 kHz

SIS - 100

278 kHz

185 kHz

Tau=100T

G_d = Signal to noise(3d)

Signal to noise (class)

Page 16: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 16Udo Rauch

The direct diode detectionThe direct diode detection

Calculation of R and C (and gain factor G)

Dependent on accelerator features:- Pickup capacity- Accelerator cycle (frequency range)- Bunch length and bunching factor

And circuitry features:- Noises induced by analog parts- No notch filter applicable

Accelerator R_fo [MΩ] C_fo [pF] G_d [dB] G_d [factor]

SIS-18 1.72 130.99 8.24 ~2.5

SIS-100 5.57 79.97 27.09 ~24

Page 17: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 17Udo Rauch

Open questionsOpen questions

Due to our frequency range (0.8-5.5MHz) and the varying bunching factor (0.6...0.2) usability of 3d-method not yet sure

Beam intensities on pickup of SIS-18 vary even within 3s from one cycle to the next by order of up to 5 magnitudes (100dB)

Pre-amplifier between pickup and diode required? one peak detector might not be sufficient (discussion ongoing)

Gain factor significantly lower compared to CERN accelerators because of much longer bunches and the higher revolution frequency

BPM data has large baseline shift which may introduce additional uncertainties

3D-circuitry for SIS-18 not yet finished Test and comparison to ‘direct digital processing’

Page 18: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 18Udo Rauch

What is LiberaWhat is Libera

Instrumentation Technology (I-Tech) – Libera is an integrated setup using a high resolution ADC for onboard data processing on a FPGA

Input actually is one BPM per Libera: 2 channels horizontally and 2 channels vertically

It is targeted to process data online delivering beam position data with delay of about 3 turns, repetition rate of tune spectra of about 100 Hz (presently only offline)

amplifierADC

and

position evaluation

Computer in control room

amplifier

pick up

4 channel ADC125 MSa / s per channel14 bit resolution256 Mb onboard memory

Page 19: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 19Udo Rauch

Motivation for digital measuring methodMotivation for digital measuring method

One point per integrated bunch (frequency variation eliminated) -> shift to tune baseband when applying FFT

For digital method bunching factor, baseline shift and frequency range is no problem

Noise averaging thanks to integration of bunch data Bunch by bunch tune separation by software

To do: Gain factor not yet evaluated (about same range as 3D) Total time for real time signal processing not yet estimated

Presently only offline analysis Feedback?

Usage of differential signal instead of single plates Used for “optimization process”

What is needed for position calculation: Windowing data stream for bunch integration Baseline restoring (due to AC coupling)

Page 20: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 20Udo Rauch

What is data looking likeWhat is data looking like

= 0.8 µs

Page 21: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 21Udo Rauch

Whole rampWhole ramp

= 0.8 µs

Page 22: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 22Udo Rauch

Whole rampWhole ramp

= 0.8 µs

Page 23: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 23Udo Rauch

Whole rampWhole ramp

= 0.8 µs

Data averaging over 1000 bunches

Page 24: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 24Udo Rauch

Whole rampWhole ramp

= 0.8 µs

Data averaging over 1000 bunches

Page 25: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 25Udo Rauch

SpectrumSpectrumf /

f_re

v

‘q’

Remark error:

No noise sidebandof DRN generator!(Only carrier freq.)

FFT slidesor Turns / 2048

Page 26: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 26Udo Rauch

Single bunch behaviourSingle bunch behaviour

Timespan of every figure: 2.6 µsNote bunch spacing

0.14 ms22 Turns

1.62 ms340 Turns

2.22 ms470 Turns

13.72 ms2950 Turns

Time and turns after start of bunch forming

Page 27: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 27Udo Rauch

Timespan of every figure: 2.6 µsNote window widths!

Time and turns after start of bunch forming

93.94ms25000 Turns

194.39ms75000 Turns

473.27ms300000 Turns

Page 28: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 28Udo Rauch

Summary and outlookSummary and outlook

- First approach to establish tune measurement system at GSI- Parameters characteristically for 3d – method calculated- First measurements with real electronics for 3d foreseen in spring

2008

- Beam position out of direct digitized data working properly- FFT to tune baseband through bunch – synchronous position data

possible- First measurements promising- Further measurements and theoretical evaluations foreseen

- Many thanks to M. Gasior and R. Steinhagen

AND

Page 29: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 29Udo Rauch

Thank you for your

attention!

Page 30: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 30Udo Rauch

Page 31: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 31Udo Rauch

Page 32: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 32Udo Rauch

Page 33: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 33Udo Rauch

The direct diode detectionThe direct diode detection

SPS Parameter / gain factor

Tau als Ebene = RC = 100

Page 34: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 34Udo Rauch

Data averaging over 1000 bunches

Single bunch position

Page 35: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 35Udo Rauch

Page 36: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 36Udo Rauch

Page 37: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 37Udo Rauch

Data acquisitionData acquisition

pick up amplifier position

evaluation Shift to frequency domain tune?

K = Sondenkonstante

KO = Offset

X

x X OX

X

s K K

( t T / 2) (t T / 2)t

(x x )y x

2

Page 38: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 38Udo Rauch

The direct diode detection (3D) (principles)The direct diode detection (3D) (principles)

Comparison to Classical Approach:

„one betatron harmonic filtering“

- Considered 4-Sigma bunch length to be about 100 ns- One obtains a cut-off of about 13.3 MHz- Thus low noise amps required because of small signals- Saturation during ramp has to be avoided

Page 39: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 39Udo Rauch

Some resultsSome results

Page 40: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 40Udo Rauch

Some resultsSome results

Time span for every actual done Fourier Transformation is 0.5 ms (25000 data points/channel)

Page 41: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 41Udo Rauch

Some resultsSome results

Page 42: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 42Udo Rauch

Some resultsSome results

Page 43: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 43Udo Rauch

Some resultsSome results

Page 44: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 44Udo Rauch

Results of one ramp cycleResults of one ramp cycle

Page 45: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 45Udo Rauch

Results of one ramp cycleResults of one ramp cycle

Page 46: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 46Udo Rauch

Results of one ramp cycleResults of one ramp cycle

Page 47: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 47Udo Rauch

Results of one ramp cycleResults of one ramp cycle

Page 48: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 48Udo Rauch

Curiosities (PosSon6)Curiosities (PosSon6)

Page 49: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 49Udo Rauch

What‘s missingWhat‘s missing

Programming, programming, programming. (matlab, mathematica,…) Calculations Identifying obtained frequencies (tune? Half tune? Amplifier? Power

Plant?) Statistics on when tune is identifiable. More data needed for statistics,

because most of recent collected data is corrupted mostly due to the parasitic frequency on BPM 6

Page 50: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 50Udo Rauch

The direct diode detection (principles)The direct diode detection (principles)

Scheme, mathematics and plots by Marek Gasior, CERN

Page 51: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 51Udo Rauch

The direct diode detection (principles)The direct diode detection (principles)

Page 52: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 52Udo Rauch

The direct diode detection (analytics / results)The direct diode detection (analytics / results)

Calculation of R and C (and gain factor G)

Dependent on:- Pickup capacity- Accelerator cycle- Bunch length- Temperature- Diode leakage current- Spectral noise density and current of Detector Amplifier- Expected tune value

Page 53: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 53Udo Rauch

Some resultsSome results

Page 54: Investigations on BaseBand tune measurements using direct digitized BPM signal - progress report -

CARE workshop Chamonix, Dec 2007 54Udo Rauch