Die Robert Bosch Fabrik in Cluj
Internal | CljP/FCM | 11/09/2015 | © Robert Bosch GmbH 2013. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Automotive Electronics
2
Kurzgeschichte
Fabrikpräsentation
Gründe für Energieeffizienz
Verbrauchsüberwachung
Building Management System
Management der reaktiven Energie (Blindleistung)
Drehzahlgeregelte Antriebe
Wärmerückgewinnung von den Kompressoren
Stromqualität
Komplexer energetischer Audit
Entwicklungsrichtungen der Energieeffizienz
Inhalt
Internal | CljP/FCM | 11/09/2015 | © Robert Bosch GmbH 2013. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Automotive Electronics
3
2013, beginnt Bosch den Bau einer neuen Fabrik für
Automobilelektronik im Tetarom 3 - Park , Gemeinde Jucu.
Es wurde als ein Öko-Gebäude konzipiert mit hohem
Energieeffizienzgrad und zahlreichen
Energiewiedergewinnungssystemen.
Eine Besonderheit des Konzepts bildet die Möglichkeit der
Erweiterung sämtlicher Systeme und Gebäude.
Kurz aus der Geschichte
Internal | CljP/FCM | 11/09/2015 | © Robert Bosch GmbH 2013. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Automotive Electronics
4
Gesamtoberfläche 215.000 m2:
Grünflächen 32.228 m2
Parkplätze und Zufahrtswege 19.608
m2
Bebaute Fläche 30.165 m2, von
welcher 39.679 m2 Nutzfläche
(Erdgeschoss, Etage und Penthouse)
Parkplätze
Abfalldeponie
Pförtnerhaus
Mensa
Hauptgebäude
Pförtnerhaus
Präsentation der Fabrik
Internal | CljP/FCM | 11/09/2015 | © Robert Bosch GmbH 2013. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Automotive Electronics
5
Cea mai ieftina forma de energie este energiaECONOMISITA.
Eficienta energetica poate face diferenta intre o organizatie de succes si una pe cale de disparitie.
Utilizarea rationala a resurselor reprezinta un dezideratde maxima importanta pentru compania noastra.
Cresterea competivitatii prin reducerea costurilor cu energia consumata.
Argumente
Die preisgünstigste Form der Energie ist die
EINGESPARTE Energie
Energieeffizienz kann den Unterschied zwischen einer erfolgreichen und einer vom Konkurrs bedrohten Organisation ausmachen
Die rationelle Nutzung der Ressourcen stellt ein Bestreben
das für unsere Gesellschaft von höchster Bedeutung ist, dar
Die Steigerung der Wettbewerbsfähigkeit durch
Kostensenkung der verbrauchten Energie
Internal | CljP/FCM | 11/09/2015 | © Robert Bosch GmbH 2013. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Entwicklung des Verbrauchs
Automotive Electronics
6
kWh
0 kW
100000 kW
200000 kW
300000 kW
400000 kW
500000 kW
600000 kW
700000 kW
800000 kW
900000 kW
1000000 kW
ma
i..1
3
iun..
13
iul..1
3
au
g..1
3
sep..
13
oct..1
3
no
v..
13
de
c..
13
ian..
14
feb..1
4
ma
r..1
4
ap
r..1
4
ma
i..1
4
iun..
14
iul..1
4
au
g..1
4
sep..
14
oct..1
4
no
v..
14
de
c..
14
ian..
15
feb..1
5
ma
r..1
5
ap
r..1
5
ma
i..1
5
iun..
15
iul..1
5
Consum energie electrica
Consum energie electrica
Stromverbrauch
Stromverbrauch
Internal | CljP/FCM | 11/09/2015 | © Robert Bosch GmbH 2013. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Automotive Electronics
7
Um eine bessere Verwaltung der Energie zu ermöglichen
bedarf es an genauen vor Ort Informationen.
Zu diesem Zweck hat unsere Fabrik bedeutende Investitionen
in Gebäudemanagementsysteme getätigt.
Die Überwachung der betreffenden Parameter ermöglicht die
Identifizierung eines optimalen Betriebszustandes, sowie
deren Abweichungen vom Omtimum.
Monitoring
Internal | CljP/FCM | 11/09/2015 | © Robert Bosch GmbH 2013. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.8
Automotive Electronics
Gesamtanschluss
Ausgänge 0.4
kV
Produktionslinien
Monitoring Instrumente
Internal | CljP/FCM | 11/09/2015 | © Robert Bosch GmbH 2013. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Automotive Electronics
9
BUS BAR
1600A
BUS BAR
250A
BUS BAR
100A
BUS BAR
800A UPS
BUS BAR
100A UPS
Stromverteilung
Produktionslinie
Internal | CljP/FCM | 11/09/2015 | © Robert Bosch GmbH 2013. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Automotive Electronics
10
Gebäudemanagementsysteme - BMS
Internal | CljP/FCM | 11/09/2015 | © Robert Bosch GmbH 2013. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Automotive Electronics
11
Gebäudemanagementsysteme - BMS - Echtzeitwerte
Internal | CljP/FCM | 11/09/2015 | © Robert Bosch GmbH 2013. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Automotive Electronics
12
Gebäudemanagementsysteme - BMS - Echtzeitwerte
Kühlwasserpu
mpen
Internal | CljP/FCM | 11/09/2015 | © Robert Bosch GmbH 2013. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Automotive Electronics
13
0.000,00 kW
2.000,00 kW
4.000,00 kW
6.000,00 kW
8.000,00 kW
10.000,00 kW
12.000,00 kW
12
3
4
5
6
7
8
9
10
11
12
13
14
151617
18
19
20
21
22
23
24
25
26
27
28
29
3031
Daily value
Consum productie
Consum zona tehnica
Consum Office + exterioare
Erfassung der monatlichen Verbrauchsdaten
Produktionsverbrauch
Technischer Verbrauch
Verbrauch Office + Außenanlagen
Internal | CljP/FCM | 11/09/2015 | © Robert Bosch GmbH 2013. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Automotive Electronics
14
Stündliche Überwachung und Erfassung der Parameter
Internal | CljP/FCM | 11/09/2015 | © Robert Bosch GmbH 2013. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Automotive Electronics
15
MWh
0
0,2
0,4
0,6
0,8
1
1,2
1,4
1,6
1,8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Consum varf 08.07.15
Consum var 08.07.15
Spitzenverbrauch
Spitzenverbrauch
Variabler Verbrauch 08.07.15
Internal | CljP/FCM | 11/09/2015 | © Robert Bosch GmbH 2013. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Automotive Electronics
16
Zeit Szenario Belüftung Büroräume
Internal | CljP/FCM | 11/09/2015 | © Robert Bosch GmbH 2013. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Automotive Electronics
17
Die Beleuchtung dieses Bereichs
ist durch Zeitschalter gesondert
geregelt.
Die Zeitschalter steuern die
Beleuchtungseinschaltung
während der Nacht bei einem
Schichtwechsel also wenn das
Personal zu den
Aufnahmestellen hin- oder
fortgeht.
Parkplatzbeleuchtung
Internal | CljP/FCM | 11/09/2015 | © Robert Bosch GmbH 2013. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Automotive Electronics
18
Um die
Blindleistungskompensation zu
gewährleisten werden 2400 KVAr
in stufenweise automatisierten
Kondensatorengruppen installiert.
Management der induktiven Reaktivenergie (Blindleistung)
Internal | CljP/FCM | 11/09/2015 | © Robert Bosch GmbH 2013. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Automotive Electronics
19
Die optimale Einstellung des
Leistungsfaktors bei den
Regulatoren der automatisierten
Kondensatorengruppen
Management der kapazitiven Reaktivenergie (Blindleistung)
Internal | CljP/FCM | 11/09/2015 | © Robert Bosch GmbH 2013. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Automotive Electronics
20
In der Regel funktionieren die für
elektrische Antriebe verwendeten
Motoren im Bereich der Nennparameter.
Sollte die Last aber variabel sein, treten
Verluste ein, da der Motor nicht der
Belastungskurve zu folgen vermag.
Drehzahlgeregelte Antriebe
Internal | CljP/FCM | 11/09/2015 | © Robert Bosch GmbH 2013. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Automotive Electronics
21
Die von den Kompressoren freigegebene Thermoenergie wird
wiederverwendet und für die Vorwärmung des Warmwassers benutzt. Die
Erhitzung bis auf die Verbrauchstemperatur wird durch ein gesonderter
Heizkessel erwirkt.
Wärmerückgewinnung von den Kompressoren
Internal | CljP/FCM | 11/09/2015 | © Robert Bosch GmbH 2013. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Automotive Electronics
22
Merkmale und Lebensdauer der
Anlagen die als Energiequelle
Strom verwenden, werden von der
Stromqualität bestimmt.
Stromqualität
Internal | CljP/FCM | 11/09/2015 | © Robert Bosch GmbH 2013. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Automotive Electronics
23
Eine eindeutige Identifizierung der Arten in denen
der Energieverbrauch stattfindet
Identifizierung potenzieller Lösungen für die
Verbesserung der Energieeffizienz
Und nicht zuletzt, verpflichtet die Gesetzgebung in
Rumänien die Verbraucher mit über 1000 tep alle 4
Jahre einen komplexen energetischen Audit
vorzunehmen.
Komplexer energetischer Audit
Energetischer
Audit
Internal | CljP/FCM | 11/09/2015 | © Robert Bosch GmbH 2013. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Automotive Electronics
24
Entwicklungsrichtungen in der Energieeffizienz
Energieverbrauch
Energieverbrauch
Automatisierte Anwendung
Einsparungen
Internal | CljP/FCM | 11/09/2015 | © Robert Bosch GmbH 2013. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Automotive Electronics
25
Entwicklungsrichtungen in der Energieeffizienz
Internal | CljP/FCM | 11/09/2015 | © Robert Bosch GmbH 2013. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Automotive Electronics
26
Argumente:
Die Mikro-Kraft-Wärme-Kopplung bedeutet die zeitgleiche Erzeugung
von Wärme und Strom in derselben Anlage aus dem gleichen
Rohstoff, beide Energieformen finden Anwendung.
Dies steigert die Energieeffizienz der Gesellschaft und reduziert die
CO2 Emissionen.
Entwicklungsrichtungen in der Energieeffizienz
Internal | CljP/FCM | 11/09/2015 | © Robert Bosch GmbH 2013. All rights reserved, also regarding any disposal, exploitation, reproduction,
editing, distribution, as well as in the event of applications for industrial property rights.
Automotive Electronics
27
Wir bedanken uns für Ihre Aufmerksamkeit!