inx-1000a - vimap-medical.com · “alternative and advantages over iodinated contrast ... cart,...
TRANSCRIPT
I N X - 1 0 0 0 AA u t o m a t i c C O
2 i n j e c t o r
“No nephro tox ic i t y and a l l e rg i c reac t ions ”
“ 1 /400 of t he iod i na ted con t ras t v i scos i t y => Sma l le r and less i nvas ive need les ”
“ Exc l us i ve and pa ten ted 100% safe and au tomat i c a i r purge sys tem”
“A l te rna t i ve and advan tages over iod i na ted con t ras t ”
A N G I O G R A P H Y I N A R T E R I A L
A N D V E N O U S F O R D I A G N O S T I C
A N D G U I D E D I N T E R V E N T I O N S
U R I N A R Y T R AC T , G A S T R O I N T E S T I N A L T R AC T A N D P E R I T O N E A L C A V I T Y
C O N T R A S T F O R C T , A N G I O G R A P H Y A N D C - A R M
C O N T R A S T F O R G U I D E D V A S C U L A R
I N T E R V E N T I O N S
I N X- 1 0 0 0A F E AT U R E S
Automat ic and safe
purge system
PATENTED
Permanent CO
2 gas mon i tor ing wi th sensors
and automat ic s top
Fr iend ly in ter face
H igh prec is ion f low de l ivery
Largerange of pressure
Contro l led by Capnograph and Pu lse Mon i tor ing
S ing le use ster i le admin is t ra t ion sets
Emergency s top
35 to 1500 mmHg
+/- 0 .5 ml/s
CO2 injector wi th heat ing system
I N X- 1 0 0 0A P ROCEDU R E S
CO2 peripheral extremity artieries
CO2 aortography Runoff
CO2 renal artery angioplasty and stenting
CO2 visceral angiography and intervention
CO2 transplant renal artery DSA
CO2 for detection of bleeding
CO2 mesenteric Artery
CO2 abdominal Aortogram
CO2 femoral arteries
CO2 popliteal arteries
CO2 guided EVAR
CO2 Iliac or pelvic atery
CO2 peripheral and central vein
CO2 upper extremity venography
CO2 for hemodialysis access
CO2 splenoportal venogram
CO2 arm venogram
CO2 vena cavography prior to filter placement
CO2 inferior vena cava
CO2 renal Vein
CO2 direct Portography
CO2 wedged hepatic venography
CO2 splenoportography
CO2 lower Limb
CO2 dialysis Fistula
CO2 pelvic Anteriogram
CO2 leg Anteriogram
CO2 renal Transplant
CO2 TIPS procedure
EXAMPLES OF PROCEDURES
Sonography
Ang iography C-Arm system
Computed Tomography (CT)
Rad iography
D I S T R I B U TORV I M A P T ECHNOLOG I E S
Paseo de la Hispanidad N°1 y N°2 - Pol ígono Industrial29130 Alhaurín de la Torre, Málaga SPAIN Tel: +33 (0) 1 73 04 92 39 or +34 933 801 270Fax: +33 (0) 1 73 04 92 44 Email : [email protected]
www. v i map -med i c a l . c om Rev. 2017/12/01 v1..01
CO2 gas supply system: (US 7/16” connector) .
Maximum permitted pressure 1500mHg according to the operating mode selected + 4 independant over pressure release valves electronical ly control led.Flow release : 0 to 100 mL/s according to the operating mode.Pressure release: 35 to 1500 mmHg to an accuracy of 1 or 10 mmHg according to operating mode selected.CO
2. concentration : 10 to 100% of CO
2. concentration
Touch panel monitor 15-inch LCD with 5 wire resist ive touch pannel usable with medical gloves.Screen showing: immediate flow, pressure, volume injected, temperature of the CO
2.
Capnography parameters : SpO2 and pulsations monitoring.Total volume of CO
2 used and low levels in the cyl inder, operating mode, user protocole.
Types of power supply: 100-240 V AC 50-60 Hz.Protection by fuses: 8 A – 250V time-lag fuses - UR.Power used: 300 VA.
Dimensions including cart, capsule 15’ ’ LCD monitor: L=83cm, D=55cm, H=164cm.Total weight including cart and panel PC: 75 kg.
Transport and storage relat ive humidity range: 20% to 85%.Operating temperature range: +10°C / +40°C.Operating relat ive humidity range: 30 to 75 %.Transport and storage temperature range: +5°C / +50°C.Operating, transport and storage atmospheric pressure range: 700hPa to 1060hPa.
Electrical protection: class 1 type BF.Conforms to European directive 93/42/CEE on medical devices: class I Ib.Conforms to standard IEC 60 601–1.Not protected against water ( IPX0).Not adapted for use in the presence of a flammable anaesthetic mixture with air, oxygen or nitrous oxide.
Main power cable.
I n s u f f l a t o r r e f e r e n c e s :INX-1000A alone. Not included: cart, high pressure flexible hose, power supply cable: INX-1000ACart for INX-1000A, CLX-1020A, VMX-1020A: CAR-XXXXD High pressure tube type C (DIN 477-1 N°6 21.8x1/4’’ ) : REGH-KIT001High pressure tube CGA940 (PIN Index): REGH-KIT002High pressure tube W27x2 - ISO5145: REGH-KIT003Remote touch panel 15’ ’ LCD monitor usable with medical gloves to control remotely the VMX-1020A and INX-1000A: REM-XXXXA
Adm i n i s t r a t i o n s e t s r e f e r e n c e s f o r I N X- 1 0 00A :Box of 24 administration sets for injector use. IS-IN-LL-A/24
P ACS i n t e r f a c e mod u l e f o r I N X- 1 0 00A :PACS interface software module sending insuff lat ion datas to PACS: PACS-1000A
Pn e uma t i c s :
I n t e r f a c e :
Powe r s u p p l i e s :
M e c h a n i c s :
Ope r a t i n g , t r a n s p o r t a t i o n , S t o r a ge :
S t a n d a r d s :
A c c e s s o r i e s e q u i pme n t :
T E CHN I C A L S P EC I F I C AT I ON S
ORD E R I NG I N FORMAT ION