inx-1000a - vimap-medical.com · “alternative and advantages over iodinated contrast ... cart,...

4
INX-1000A Automatic CO 2 injector “No nephrotoxicity and allergic reactions” “1/400 of the iodinated contrast viscosity => Smaller and less invasive needles” “Exclusive and patented 100% safe and automatic air purge system” “Alternative and advantages over iodinated contrast” ANGIOGRAPHY IN ARTERIAL AND VENOUS FOR DIAGNOSTIC AND GUIDED INTERVENTIONS URINARY TRACT, GASTROINTESTINAL TRACT AND PERITONEAL CAVITY CONTRAST FOR CT, ANGIOGRAPHY AND C-ARM CONTRAST FOR GUIDED VASCULAR INTERVENTIONS

Upload: leminh

Post on 29-Aug-2018

249 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: INX-1000A - vimap-medical.com · “Alternative and advantages over iodinated contrast ... cart, high pressure flexible hose, power supply cable: INX-1000A Cart for INX-1000A, CLX-1020A,

I N X - 1 0 0 0 AA u t o m a t i c C O

2 i n j e c t o r

“No nephro tox ic i t y and a l l e rg i c reac t ions ”

“ 1 /400 of t he iod i na ted con t ras t v i scos i t y => Sma l le r and less i nvas ive need les ”

“ Exc l us i ve and pa ten ted 100% safe and au tomat i c a i r purge sys tem”

“A l te rna t i ve and advan tages over iod i na ted con t ras t ”

A N G I O G R A P H Y I N A R T E R I A L

A N D V E N O U S F O R D I A G N O S T I C

A N D G U I D E D I N T E R V E N T I O N S

U R I N A R Y T R AC T , G A S T R O I N T E S T I N A L T R AC T A N D P E R I T O N E A L C A V I T Y

C O N T R A S T F O R C T , A N G I O G R A P H Y A N D C - A R M

C O N T R A S T F O R G U I D E D V A S C U L A R

I N T E R V E N T I O N S

Page 2: INX-1000A - vimap-medical.com · “Alternative and advantages over iodinated contrast ... cart, high pressure flexible hose, power supply cable: INX-1000A Cart for INX-1000A, CLX-1020A,

I N X- 1 0 0 0A F E AT U R E S

Automat ic and safe

purge system

PATENTED

Permanent CO

2 gas mon i tor ing wi th sensors

and automat ic s top

Fr iend ly in ter face

H igh prec is ion f low de l ivery

Largerange of pressure

Contro l led by Capnograph and Pu lse Mon i tor ing

S ing le use ster i le admin is t ra t ion sets

Emergency s top

35 to 1500 mmHg

+/- 0 .5 ml/s

CO2 injector wi th heat ing system

Page 3: INX-1000A - vimap-medical.com · “Alternative and advantages over iodinated contrast ... cart, high pressure flexible hose, power supply cable: INX-1000A Cart for INX-1000A, CLX-1020A,

I N X- 1 0 0 0A P ROCEDU R E S

CO2 peripheral extremity artieries

CO2 aortography Runoff

CO2 renal artery angioplasty and stenting

CO2 visceral angiography and intervention

CO2 transplant renal artery DSA

CO2 for detection of bleeding

CO2 mesenteric Artery

CO2 abdominal Aortogram

CO2 femoral arteries

CO2 popliteal arteries

CO2 guided EVAR

CO2 Iliac or pelvic atery

CO2 peripheral and central vein

CO2 upper extremity venography

CO2 for hemodialysis access

CO2 splenoportal venogram

CO2 arm venogram

CO2 vena cavography prior to filter placement

CO2 inferior vena cava

CO2 renal Vein

CO2 direct Portography

CO2 wedged hepatic venography

CO2 splenoportography

CO2 lower Limb

CO2 dialysis Fistula

CO2 pelvic Anteriogram

CO2 leg Anteriogram

CO2 renal Transplant

CO2 TIPS procedure

EXAMPLES OF PROCEDURES

Sonography

Ang iography C-Arm system

Computed Tomography (CT)

Rad iography

Page 4: INX-1000A - vimap-medical.com · “Alternative and advantages over iodinated contrast ... cart, high pressure flexible hose, power supply cable: INX-1000A Cart for INX-1000A, CLX-1020A,

D I S T R I B U TORV I M A P T ECHNOLOG I E S

Paseo de la Hispanidad N°1 y N°2 - Pol ígono Industrial29130 Alhaurín de la Torre, Málaga SPAIN Tel: +33 (0) 1 73 04 92 39 or +34 933 801 270Fax: +33 (0) 1 73 04 92 44 Email : [email protected]

www. v i map -med i c a l . c om Rev. 2017/12/01 v1..01

CO2 gas supply system: (US 7/16” connector) .

Maximum permitted pressure 1500mHg according to the operating mode selected + 4 independant over pressure release valves electronical ly control led.Flow release : 0 to 100 mL/s according to the operating mode.Pressure release: 35 to 1500 mmHg to an accuracy of 1 or 10 mmHg according to operating mode selected.CO

2. concentration : 10 to 100% of CO

2. concentration

Touch panel monitor 15-inch LCD with 5 wire resist ive touch pannel usable with medical gloves.Screen showing: immediate flow, pressure, volume injected, temperature of the CO

2.

Capnography parameters : SpO2 and pulsations monitoring.Total volume of CO

2 used and low levels in the cyl inder, operating mode, user protocole.

Types of power supply: 100-240 V AC 50-60 Hz.Protection by fuses: 8 A – 250V time-lag fuses - UR.Power used: 300 VA.

Dimensions including cart, capsule 15’ ’ LCD monitor: L=83cm, D=55cm, H=164cm.Total weight including cart and panel PC: 75 kg.

Transport and storage relat ive humidity range: 20% to 85%.Operating temperature range: +10°C / +40°C.Operating relat ive humidity range: 30 to 75 %.Transport and storage temperature range: +5°C / +50°C.Operating, transport and storage atmospheric pressure range: 700hPa to 1060hPa.

Electrical protection: class 1 type BF.Conforms to European directive 93/42/CEE on medical devices: class I Ib.Conforms to standard IEC 60 601–1.Not protected against water ( IPX0).Not adapted for use in the presence of a flammable anaesthetic mixture with air, oxygen or nitrous oxide.

Main power cable.

I n s u f f l a t o r r e f e r e n c e s :INX-1000A alone. Not included: cart, high pressure flexible hose, power supply cable: INX-1000ACart for INX-1000A, CLX-1020A, VMX-1020A: CAR-XXXXD High pressure tube type C (DIN 477-1 N°6 21.8x1/4’’ ) : REGH-KIT001High pressure tube CGA940 (PIN Index): REGH-KIT002High pressure tube W27x2 - ISO5145: REGH-KIT003Remote touch panel 15’ ’ LCD monitor usable with medical gloves to control remotely the VMX-1020A and INX-1000A: REM-XXXXA

Adm i n i s t r a t i o n s e t s r e f e r e n c e s f o r I N X- 1 0 00A :Box of 24 administration sets for injector use. IS-IN-LL-A/24

P ACS i n t e r f a c e mod u l e f o r I N X- 1 0 00A :PACS interface software module sending insuff lat ion datas to PACS: PACS-1000A

Pn e uma t i c s :

I n t e r f a c e :

Powe r s u p p l i e s :

M e c h a n i c s :

Ope r a t i n g , t r a n s p o r t a t i o n , S t o r a ge :

S t a n d a r d s :

A c c e s s o r i e s e q u i pme n t :

T E CHN I C A L S P EC I F I C AT I ON S

ORD E R I NG I N FORMAT ION