iris range : «unconventional» conventional detectors

24
Iris Range : «Unconventional» conventional detectors

Upload: prosper-warren

Post on 23-Dec-2015

222 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Iris Range : «Unconventional» conventional detectors

Iris Range : «Unconventional» conventional detectors

Page 2: Iris Range : «Unconventional» conventional detectors

Introducing new devices

IRIS is a range of detectors which represent an innovation in the conventional fire detection

ID100 – SMOKE DETECTORID200 – HEAT DETECTORID300 – COMBINED SMOKE AND HEAT DETECTOR

Page 3: Iris Range : «Unconventional» conventional detectors

Introducing new devices

Iris detectors has been designed and are manufactured at Inim electronics, it is a 100% italian product

Page 4: Iris Range : «Unconventional» conventional detectors

Introducing new devices

Each device of the new ranges has been approved by LPCB which is one of the most prestigious notification body in fire detection

EN54-5 : Heat Detectors

EN54-7 : Smoke Detectors

Page 5: Iris Range : «Unconventional» conventional detectors

KEY FEATURES

Optical Smoke detectors are based on th eprinciple of the light scattering, to avoid false alarm it is important to avoid contaminations in the analysis chamber

Page 6: Iris Range : «Unconventional» conventional detectors

Introducing new devices

Top side completely sealed to avoid dust or water condensation to reach the chamber

One of the most common false alarm or fault reason is the dust coming from the pipes or condensating water dropping from the top side

Page 7: Iris Range : «Unconventional» conventional detectors

Introducing new devices

Metal mash agains insect wit less than 500um holes diameter

One of the biggest problems of optical smoke detectors is dust or insect entering in the chamber

Page 8: Iris Range : «Unconventional» conventional detectors

Introducing new devices

Electronic circuit completely WAX coated to avoid any contamination

Moisture or environmental pollution may affect the behaviour of hi sensitive electronics circuits in the detector

Page 9: Iris Range : «Unconventional» conventional detectors

Introducing new devices

Sensitive part of the circuit completely shielded by a metal cage

Electromagnetic noise may affect the measurement of the hi gain amplifier generating false alarms

Page 10: Iris Range : «Unconventional» conventional detectors

Introducing new devices

Last generation CPU inside each detector whith hi false alarm rejection algorithm

The measurement of the smoke chamber and thermal probe are evaluated by the internal CPU and by means of the algorithm designed from the Inim R&D department an hi rejection to false alarm is achieved

Page 11: Iris Range : «Unconventional» conventional detectors

Introducing new devices

Smoke chamber easy to open for clean up operations

In case of detector’s chamber contamination detector can be easily opened and cleaned with some air or a soft brush

Page 12: Iris Range : «Unconventional» conventional detectors

Introducing new devices

Each Detector is Full tested with automatic test equipment which measure each single component and verify each electrical connection

Page 13: Iris Range : «Unconventional» conventional detectors

Introducing new devices

Each Detector is Calibrated with a two stage process : one in free air and another one in a smoke tunnel to ensure the same response from each sample

Page 14: Iris Range : «Unconventional» conventional detectors

Introducing new devices

Each Detector is subjected to a «Burn IN test» of 24 hours: the 80% of electronic components failure occur during the first 24 hours of theyr life, detectors live theyr first 24 hours in our burn in test!

Page 15: Iris Range : «Unconventional» conventional detectors

Introducing new devices

Universal mounting base for every detector model

Clip for line continuity restore in case of detector removal

Page 16: Iris Range : «Unconventional» conventional detectors

Introducing new devices

Relay base available for interface with intrusion systems

Page 17: Iris Range : «Unconventional» conventional detectors

Introducing new devices

Each device is identifyed by a serial number

The serial number is reported on the back label and on two small detachable labels : this allow to stick a serial number to map and a serial number to mounting base

Page 18: Iris Range : «Unconventional» conventional detectors

Introducing new devices

Why “unconventional” ?

During commissioning or maintenances operations it is possible to disconnect the detector line from panel…

…and connect it to EDRV100 driver …

EDRV100 can operate connected to a PC …

… or stand alone thanks to its internal battery

US

B

Page 19: Iris Range : «Unconventional» conventional detectors

Introducing new devices

Identify each conventional detector connected on the line

And for each one…

Thanks to Versa++ technology is possible to:

Page 20: Iris Range : «Unconventional» conventional detectors

Introducing new devices

Operating options can be selected (Led Blink, remote blink etc.)

Smoke Sensitivity can be adjusted

Heat Sensitivity can be adjusted

Smoke and heat combination mode can be selected :•OR Mode•AND Mode•Only Heat•Only Smoke•PLUS Mode

Red Led, Yellow Led and remote output can be manually activated

Any fault (chamber contamination, chamber fault, thermal probe fault etc) is reported

Page 21: Iris Range : «Unconventional» conventional detectors

Introducing new devices

A full diagnostic of each detector is available:

Smoke chamber contamination level

Real time Smoke value graph

Real time temperature value graph

Page 22: Iris Range : «Unconventional» conventional detectors

Introducing new devices

Each detector store the last 5 minutes of smoke and tempearture values before the last alarm providing a powerful tool for investigate over the alarm causes

Page 23: Iris Range : «Unconventional» conventional detectors

Introducing new devices

DON’T YOU THINK IRIS IS A STEP AHEAD?

Page 24: Iris Range : «Unconventional» conventional detectors

THANK YOU