irrigation management practices
DESCRIPTION
Irrigation Management Practices. Lyndon Kelley MSU Extension / Purdue University Irrigation Management Agent. WWW.msue.msu.edu - find St. Joseph Co. - then hit the Irrigation button. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/1.jpg)
IrrigationManagement Practices
Lyndon KelleyMSU Extension / Purdue University Irrigation Management Agent
WWW.msue.msu.edu - find St. Joseph Co. - then hit the Irrigation button
Thanks to Dr. Ted Loudon - MSU Ag Engineering Dr. Ron Goldy - MSU Extension
Dr. Jeff Andreasen – MSU Geography Dr. Steve Miller - MSU Ag Engineering
![Page 2: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/2.jpg)
Tools for Irrigation Stewardship
1. Irrigation System Uniformity
2. Preventing Irrigation Runoff (comparing irrigation application rate to soil infiltration rate)
3. Irrigation Scheduling
4. Backflow protection
5. Avoiding water use conflicts
6. Record keeping
![Page 3: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/3.jpg)
Irrigation power cost vary on: - power source - power cost - system pressure
Average fuel cost for pumping NE. USA: 2006 Cost per acre inch of irrigation waterEnergy source
PressureElectric Diesel / propane
Low <35 psi $1.76 $2.56 / 2.30Med. 35 to 95 psi $2.48 $3.76 / 3.27High >100psi $ 3.56 $ 4.87 / 3.90
![Page 4: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/4.jpg)
Day to Day
Power Operation
Costs
Table 2. Comparative Costs of Various
Energy Sources to Obtain Equal Work Output per Dollar
SpentSource: AE-111 Comparable
Costs of Various Energy Sources for Irrigation
Pumping
Gasoline ($/gallon) Diesel ($/gallon) Propane ($/gallon) Electricity (kw-hr)
.90 1.18 .71 9.4
1.00 1.31 .79 10.4
1.10 1.44 .87 11.4
1.20 1.57 .95 12.5
1.30 1.70 1.03 13.5
1.40 1.83 1.11 14.6
1.50 1.97 1.19 15.6
1.60 2.10 1.26 16.7
1.70 2.23 1.34 17.7
1.80 2.36 1.42 18.7
1.90 2.49 1.50 19.8
2.00 2.62 1.58 20.8
2.10 2.75 1.66 21.8
2.20 2.88 1.74 22.8
2.30 3.01 1.82 23.9
2.40 3.14 1.90 25.0
2.50 3.27 1.98 26.0
2.60 3.40 2.06 27.0
2.70 3.53 2.13 28.1
2.80 3.67 2.22 29.2
2.90 3.80 2.29 30.1
3.00 3.93 2.37 31.2
![Page 5: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/5.jpg)
Scientific Investigations Report 2005–5284U.S. Department of the InteriorU.S. Geological Survey
Estimated rainfall recharge
![Page 6: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/6.jpg)
0
1
2
3
4
5
6
7
Jan Feb Mar Apr May June July Aug Sept Oct Nov Dec
Inch
es o
f Wat
er
Corn Water UseNormal Rainfall
Crop need15.6” total
Normal rainfall34.6
Needed Irrigation5.5”
![Page 7: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/7.jpg)
0
10000
20000
30000
40000
50000
60000
70000
80000
90000
100000
1969 1974 1978 1982 1987 1992 19970
10
20
30
40
50
60
70
St. Joseph Co.Kalamazoo CoSturgis wellSchoolcraft well
Thirty years of Increasing Irrigation have not Impacted Municipal Water Well Depths
![Page 8: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/8.jpg)
Have you seen yield map patterns that match the irrigation system
configuration?
![Page 9: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/9.jpg)
• Irrigator trainings (Extension, SCD, NRCS )• Private consultants• SCD
Irrigation System Uniformity -Options
![Page 10: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/10.jpg)
Irrigation System Uniformity
An 1” application should be 1” everywhere in the irrigated field
•10% or less deviation from the average is ideal.•Over applied area will likely be over applied each application•Under applied areas will likely be under applied each application
A 30% deviation on a field in an 8” irrigation application year will have areas receiving as little as 5.6” and as great as 10.4”
Repair all visible system leaks and problems first.
![Page 11: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/11.jpg)
Evaluating Irrigation System Uniformity
Standards and Methods for Evaluation of Irrigation System Uniformity
• Two commonly accepted standards or methods are available as guidelines for performing evaluations of Irrigation System Uniformity.
• ASAE Standards (436.1) — Available at: http://www.kbs.msu.edu/mgsp/resources.htm
• NRCS Handbook — Available at your local Natural Resource Conservation Service office or http://www.wcc.nrcs.usda.gov/nrcsirrig/irrig-handbooks-part652-chapter15.html
![Page 12: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/12.jpg)
Irrigation System Uniformity
Basic system evaluation
Collect enough uniform container to to place every 10 feet the length of the system or across the application pattern.
Spread the container every ten feet from the center point to the outside edge of the application area.
Run the machine at standard setting over the container.
Measure and record the water volume caught by each container
Note sample point varying greater than 50% of the average.
![Page 13: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/13.jpg)
Evaluating Irrigation Uniformity Catch can
stands
A simple , inexpensive catch can stand can be built using:1. 32 oz. Deposable soda cup (Taco Bell cup)2. 3” plastic drain pipe cut to 5” in length3. 2”x3” stud cut to length to wedge into plastic drain pipe 4. Drill hole 1.5” into cut 2”x3” stud chucks, drill hole should
snuggly fit electric fence post 5. Steel ( step in ) electric fence post
Electric fence post and cups can be stored and transported in separate stacks. The 2”x3” stud chucks wedge into the base of the cut plastic drain pipe sections and make the transition between the cup and post. Screw maybe pace through the side of the plastic drain pipe into the 2”x3” stud chucks.
Total cost per unit is less than a dollar and require only a saw, drill and screw driver. It will allow data collection
![Page 14: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/14.jpg)
Evaluating Irrigation System Uniformity
Pivot Extensions (cornering arm or Z-arm)• Some center pivot irrigation systems are designed to
expand the wetted area to allow coverage of corner or odd-shaped fields, often referred to as cornering arms or Z-arm. These systems require two separate evaluations if the extension accounts for 30 percent or more of the irrigated portion of the field. One evaluation will evaluate the system while extended, and a second when the arm is not deployed.
![Page 15: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/15.jpg)
Overview of Evaluation of Irrigation System Uniformity Guidelines (center pivot)
1. Have the producer walk the system length and note any application problems while the system is applying water. All known application problems need to be corrected before doing an evaluation of Irrigation System Uniformity.
2. Have the producer start the system and establish a setting for his normal application (avoid weather extremes).
3. Run the system for 10 minutes or more without changes to water supply system.1. Place catch cans in a line from the center pivot point past the outer edge of the wetted
area. 2. Catch cans should be placed to form a straight line from the pivot point to a point on the
outer edge of the wetted area.3. Space catch cans 20 feet apart for system overhead impact sprinklers, and 10 feet apart
for all other center pivot application systems. 4. Place catch cans with opening at a height above the crop, or in a field opening width four
times greater than the height difference between the crop and catch can opening.5. A drop of mineral oil may be added to each catch can to minimize evaporation if a
reading cannot be taken immediately and conditions favoring evaporation are prevalent.6. If the catch can placement falls into the wheel tracks, it may be moved one to two feet to
avoid damage. 4. Record the number of catch cans placed, the producer’s intended application,
catch can opening diameter and other pertinent information. A sample record sheet to use for data collection follows.
5. Record volume collected from each catch can (ml.).6. Record the locations of pivot wheel lanes
![Page 16: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/16.jpg)
Evaluation of DataCleaning the Data1. Catch can data from the first 10 percent of the system length closest to the
center pivot point should be ignored. The “average catch can (ml)” data replaces the first catch can data points. The actual “distance from center point” is entered for the first data point (remaining after deletion of other points closer to the center pivot point). Coverage near the center point of the system represents such a small amount of the total system coverage deviation from the average, that it yields little effect on the machine’s overall uniformity.
2. Catch can data from the outer edge of the wetted area is deleted from the data set when the volume is less than 70 percent of the average. Removing the data that tails off at the outer edge of the system designates the effective irrigated area, and avoids dilution of the data points representing the actual targeted irrigated area.
3. Up to three percent of the data points should be removed if it is an extreme deviation from the average. This is done after the outer edge data has been removed to define the effective irrigated area and up to 20 percent of the inner area data has been removed. A few catch cans could collect extreme data that is not representative of the system area, like water running from a trust rod or brace rod directly to the cup.
![Page 17: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/17.jpg)
System Uniformity Coefficient
1. System Uniformity Coefficient is a numeric judgment of the overall performance of an irrigation system’s ability to evenly apply water to the field.
2. A System Uniformity Coefficient of 85 percent or greater, is considered not to need major adjustments to the sprinkler package, although individual sections of the irrigator may benefit from corrections (green or black in the spreadsheet).
3. System Uniformity Coefficient of 80 to 85 percent may need further analysis of the sprinkler package, and individual sections of the irrigator would benefit from corrections (yellow in the spreadsheet).
4. System Uniformity Coefficient of less than 80 percent requires an adjustment to the sprinkler package design and correction of individual sections of the sprinkler package (red in the spreadsheet).
![Page 18: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/18.jpg)
2640’
Field #9
![Page 19: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/19.jpg)
2640’
Field #9
![Page 20: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/20.jpg)
2640’
Field #9
![Page 21: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/21.jpg)
Field #9
![Page 22: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/22.jpg)
Creating a Take-home Message for the ProducerThe System Uniformity Coefficient provides the producer with a
report of the overall performance of the system. Almost all systems will benefit from some corrections.
Correction of areas of the system with greater than 20 percent deviation from average (red in the spreadsheet) will improve performance.
Entering a second data set, replacing the red (high deviation) data with the “average catch can (ml)” data, will create a before/after scenario that will identify the benefits of repairs or corrections to the system.
Graph of performance The Excel spreadsheet can produce a line graph of systems
uniformity. The data will not be weighted for coverage area represented by each cup.
Entering pivot wheel tracks into the graph using Microsoft standard AutoShape will make the graph more usable to irrigators.
![Page 23: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/23.jpg)
Catch Can Volume (ml)
0
20
40
60
80
100
120
140
160
180
0 200 400 600 800 1000 1200 1400 1600Distance from Pivot (ft)
Can
Volu
me
(ml)
Catch Can Volume (ml)
Tower 1
Tower 3
Tower 5
Tower 7 Tower
8
Sprinkler overlap with end gun
http://web1.msue.msu.edu/stjoseph/anr/anr.htm
![Page 24: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/24.jpg)
Irrigation System Uniformity
•Most system are designed to have 90% or better uniformity
•Changes in volume and pressure from design parameters will cause reduction in uniformity
•Some sprinklers can perform well over a large change in pressure over others
•Multiple overlaps tends to reduce potential problems
![Page 25: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/25.jpg)
Greatest improvement needed• End gun stop adjustment
• Water supply over or under design
• End gun orifice, too little or too much
• Wrong sprinkler or tip
• Leaks, plugs and no turn sprinklers
![Page 26: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/26.jpg)
Water supply over or under designsupply over design yield tail up, supply under design yield tail down
Example of Water supply under volume for sprinkler design
![Page 27: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/27.jpg)
Sprinkler overlap with end gun
Tower 1 Tower 2 Tower 3
![Page 28: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/28.jpg)
Catch Can Volume (ml)
0
10
20
30
40
50
60
70
0 100 200 300 400 500 600 700Distance from Pivot (ft)
Can
Volu
me
(ml)
Catch CanVolume (ml)
Poly. (CatchCan Volume(ml))
tower 3tower 1 tower 2
tower 4
![Page 29: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/29.jpg)
Catch Can Volume (ml)
0
50
100
150
200
250
0 200 400 600 800 1000 1200 1400 1600Distance from Pivot (ft)
Can
Volu
me
(ml)
Catch CanVolume (ml)
Poly. (CatchCan Volume(ml))
tower 5tower 1 tower 3 tower 7
![Page 30: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/30.jpg)
![Page 31: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/31.jpg)
165’
825’
1320’1155’
8 acres6 acres330’
495’
660’
990’
2 acres
18 acres31 acres
49 acres
71 acres
96 acres126acres
10 acres
13 acres
18 acres
22 acres
25 acres
30 acres
Total Acres
Feet from center
4145’3109’
2072’
5181’6217’
7253’8290’
circumference
Over and under
application issue affect the majority
of the application
area
![Page 32: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/32.jpg)
Most system apply within 85% of the expected application
Application is 4 %
under expectation
![Page 33: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/33.jpg)
Measure flow at desired pressure prior to ordering sprinkler package
Poor performance:
Ask dealer to measure flow at peak water use season and compare to design parameters.
![Page 34: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/34.jpg)
![Page 35: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/35.jpg)
![Page 36: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/36.jpg)
Preventing Irrigation Runoff (comparing irrigation application rate to soil
infiltration rate)
![Page 37: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/37.jpg)
Preventing Irrigation Runoff (comparing irrigation application rate to soil
infiltration rate)
Sprinkler package or nozzle selection along with pressure dictates water application rate .
Factors that increase runoff :•Small Wetted area or throw of sprinkler•Low Pressure •Larger applications volumes•Soil compaction•Heavy soils•Slope•Row hilling
![Page 38: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/38.jpg)
Instructions for completing the Evaluating Potential Irrigation Runoff form :
1. Identify the areas of the irrigated field that has the lowest
infiltration rates. (heavy soils, slopes, surface compaction).
2. Select a transit line in the wetted area just behind the machine that covers the identified lowest infiltration rates of the field identified above.
![Page 39: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/39.jpg)
Instructions for completing the Evaluating Potential Irrigation Runoff form – continued
3. Pace or measure 50 feet between observations starting at
the pivot point and progressing to the furthest reaches of the machine.
4. Record observations for each location; look at several (4-5 areas) representing the row contour and differences in row traffic of the location. Record any specific concerns that may affect the application (drips or leaks) or affect the soils ability to take in water (compaction, row contours)
Key for Observation column A- no observed puddling, ponding or sheen between rows B- puddling, ponding or sheen between rows identified, but no observed runoff or flow of water C-observed runoff or flow of water
![Page 40: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/40.jpg)
Calculating Instantaneous Application Rate
• Flag the leading edge of the wetted area just inside of the last tower of the pivot.
• Running the pivot at common speed with a measured and known application rate.
• Using a stop watch measure the time elapsed from the first drops hitting the flag till the last.
• Divide the measured and known application rate for the spot by the time elapsed.
• Convert to Minute to provide 1 inch application.
![Page 41: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/41.jpg)
Instantaneous Application Rate
1.Time it from first drop of irrigation to last 2.Divide by know application rate3.Convert to minute to provide 1” of irrigation
![Page 42: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/42.jpg)
Instantaneous Application Rate
John applied .75 inches in 21 minute
.75 inches = 1.00 inches 21 min. ? = 28
min./inch
![Page 43: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/43.jpg)
![Page 44: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/44.jpg)
The Goal
• Apply a consistent uniform amount of water over the whole field.
• Apply water at a rate (volume/time ) that can infiltrate into soil avoiding runoff.
• Avoid water loss to air or off target.
![Page 45: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/45.jpg)
The larger the wetted area the slower the rate of application.Average 1’ rainfall comes over 4 hours.
An 1’ rainfall over an hour is considered a “Toad strangler”
Sprinkler packages are commonly available with instantaneous application rates from 1” per 12 minutes to 1” per 80 minutes
![Page 46: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/46.jpg)
Angle
![Page 47: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/47.jpg)
Height
![Page 48: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/48.jpg)
Preventing Irrigation Runoff (comparing irrigation application rate to soil
infiltration rate)
Management factors that increase runoff:•Larger applications volumes•Soil compaction•Heavy soils•Slope•Row hilling
![Page 49: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/49.jpg)
Irrigation System Uniformity
Sprinkler package or nozzle selection along with pressure dictates water application rate .
Factors that increase runoff:•Small wetted area or throw of sprinkler•Low Pressure
![Page 50: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/50.jpg)
Instantaneous application
rate
165’
825’
1320’1155’
8 acres6 acres330’
495’
660’
990’
2 acres
18 acres31 acres
49 acres
71 acres
96 acres126acres
10 acres
13 acres
18 acres
22 acres
25 acres
30 acres
Total Acres
Feet from center
4145’3109’
2072’
5181’6217’
7253’8290’
circumference
3 days / circle @ 1”3 days = 4320 min.
8290’ / 4320 min.= = 1.92’/minute
20’ ft. wetted area== 1” / 10.4 Minutes
40’ ft. wetted area== 1” / 20.8 Minutes
![Page 51: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/51.jpg)
Irrigation Scheduling Checkbook Method
![Page 52: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/52.jpg)
Think of your soil as a bank
Intake rate:Water applied faster than the soil intake rate is lost.
Deletion:Plants can pull out only 30 - 60% of the water
Water holding capacity:The soil (bank) can hold only a given volume of water before it allow it to pass lower down.
Rooting depth:The plant can only get water to the depth of it’s roots.
Soil type :Heavier soil can hold more water / foot of depth than light soils
Water lost from the bottom of the profile can wash out (leach) water soluble nutrients and pesticides.
![Page 53: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/53.jpg)
![Page 54: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/54.jpg)
Soil Name
DepthInches
Available water holding capacity
Average Available water holding capacity
Ave. Available water holding capacity ( 24 in.)
Ave. Available water holding capacity ( 36 in.)
Oshtemo 0 - 1414 – 3535 - 60
0.10 – 0.150.12 – 0.190.06 – 0.10
0.1250.1550.08
14” x 0.125=1.7510” x 0.155=1.55----------------------- = 3.3
14” x 0.125= 1.7521” x 0.155= 3.26 1” x 0.08 = 0.08----------------------- = 5.09
Spinks 0 – 1010 – 2626 - 60
0.08 – 0.100.08 – 0.100.04 – 0.08
0.090.090.06
10” x 0.09= 0.914” x 0.09= 1.26----------------------- = 2.16
10” x 0.09= 0.916” x 0.09= 1.26 8” x 0.06= 0.48----------------------- = 2.64
Calculating Water Holding Capacity
![Page 55: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/55.jpg)
Soil Name
DepthInches
Available water holding capacity
Average Available water holding capacity
Ave. Available water holding capacity ( 24 in.)
Ave. Available water holding capacity ( 36 in.)
Bronson 0 - 1011 – 2627 – 3435 - 60
0.13 – 0.150.12 – 0.180.06 – 0.080.02 – 0.04
0.140.150.070.03
10” x 0.14=1.414” x 0.15=2.7----------------------- = 4.1
10” x 0.14=1.416” x 0.15= 3.26 8” x 0.07 = 0.562” x 0.03 = 0.06----------------------- = 5.28
Spinks 0 – 1010 – 2626 - 60
0.08 – 0.100.08 – 0.100.04 – 0.08
0.090.090.06
10” x 0.09= 0.914” x 0.09= 1.26----------------------- = 2.16
10” x 0.09= 0.916” x 0.09= 1.26 8” x 0.06= 0.48----------------------- = 2.64
Calculating Water Holding Capacity
![Page 56: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/56.jpg)
Available Water Holding Capacity
Soil Type/ depth
Bronson Capac Oshtemo Spinks
0”to 6”0”to 6”
.84” .84”
1.2”1.2”
.75”
.75”.54”.54”
6”to 12”0”to 12”
.86”1.70”
1.2”2.4”
.75”1.50”
.54”1.08”
12’ to 18”0”to 18”
.90”2.60”
.99”3.39”
.87”2.37”
.54”1.62”
18’ to 24”0” to 24”
.90”3.50”
.99”4.38”
.93”3.30”
.54”2.16”
24’ to 30”0” to 30”
.58”4.80”
.99”5.37”
.93”4.23”
.42”2.58”
30” to 36” 0”to 36”
.34”5.14”
.93”6.30”
.86”5.06”
.36”2.94”
![Page 57: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/57.jpg)
Rain Gauges
• Basic unit – 2 inch opening
• Cost less than $10• One rain gauge for
each 40 acres.• Recording rain gauge
cost $50 - $100
![Page 58: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/58.jpg)
Water Quantity Needed• Irrigation water replaces the plant water use (removed
from soil)• Water use is directly correlated to light interception• 50% light interception results in about 50% of the
maximum water use• Maximum water use mid-July early August, full light
interception, highest temperatures brightest and longest days.
Evapotranspiration (ET) = fn (net radiation) +fn (temperature) +fn (wind speed) +fn (air humidity)
![Page 59: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/59.jpg)
Weighing Lysimeter
Rain and Irrigation increase weightEvapotransporation decrease weight
![Page 60: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/60.jpg)
Crop Water use curve
0
0.05
0.1
0.15
0.2
0.25
0.3
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
Weeks after emergence
Wat
er u
se (i
nche
s)
Series1
Series2
Series3
Series4
Series5
Field beans Soys
Corn
Alfalfa
Field beans
Corn
Soys
Potato
Alfalfa
From Minnesota Extension bulletin “Irrigation Scheduling”, assuming temperature 80-89
![Page 61: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/61.jpg)
![Page 62: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/62.jpg)
![Page 63: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/63.jpg)
![Page 64: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/64.jpg)
![Page 65: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/65.jpg)
1. Irrigation Runoff (comparing irrigation application rate to soil infiltration rate) 0 -30 % loss
3. Evaporative loss to the air•Minimal loss in our humid area•0 – 6%•Estimated 4-6% loss in Nebraska
Catch Can Volume (ml)
0
20
40
60
80
100
120
140
160
180
0 200 400 600 800 1000 1200 1400 1600Distance from Pivot (ft)
Can
Volu
me
(ml)
Catch Can Volume (ml)
Sprinkler overlap with end gun
2. Lack of system uniformity• 5-35% loss in effectivenessThree factor
reducing effective water application
![Page 66: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/66.jpg)
Average application efficiency
Inches of application
70% 80% 90%
0.5” .35 .40 .45
0.6” .42 .48 .54
0.7” .49 .56 .63
0.8” .56 .64 .72
0.9” .63 .72 .81
1.0” .70 .80 .90
1.1” .77 .88 .99
1.2” .84 .96 1.08
1.3” .91 1.04 1.17
Net application at various application rates
![Page 67: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/67.jpg)
Necessary application rate to achieve effective evapo-transportation rates at various application efficiencies
Average application efficiency
Desired Inches of effective application 70% 75% 80% 85% 90% 95%
0.16 0.21 0.20 0.19 0.18 0.18 0.17
0.18 0.23 0.23 0.22 0.21 0.20 0.19
0.20 0.26 0.25 0.24 0.23 0.22 0.21
0.22 0.29 0.28 0.26 0.25 0.24 0.23
0.24 0.31 0.30 0.29 0.28 0.26 0.25
0.26 0.34 0.33 0.31 0.30 0.29 0.27
0.28 0.36 0.35 0.34 0.32 0.31 0.290.30 0.39 0.38 0.36 0.35 0.33 0.320.32 0.42 0.40 0.38 0.37 0.35 0.34
![Page 68: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/68.jpg)
Quantity Needed
• Maximum water use for most crops is .27 - .32 in./day
• 3 gal/minute/acre pump capacity = 1”/week
• 5 gal/minute/acre pump capacity = .25 in./day
• 7 gal/minute/acre pump capacity =.33 in./day, 1”every 3 days
• 500 gal/minute pump can provide 1” every 4 days on 100 acres
![Page 69: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/69.jpg)
Quantity NeededIn a hot 1st week of August John’s corn crop ET. was .30 in./dayJohn’s field has a AWC of 3.0 in. (Available water capacity)
He started irrigating when the AWC was 1.0 in. down
John’s irrigation system can apply .20 in./day.
By the end of the week how far behind is John? (.30 -.20)x7 =.70 in.
During 2nd week of August, ET. remains .30 in./day, John shuts down 2 days for repair. By week end how far behind is John?
(.5 +.6)= 1.1in. 2.80 in. total deficit 3rd. Week, no rain, John’s corn field is hurting.
![Page 70: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/70.jpg)
Limited water supply irrigation management
• Diversify the crops sharing the water supply between high and low water use.
• Stager planting date to stager peak water need times.
• Plant part of irrigated area to a sacrifice crop to neglect during extended drought.
• Start irrigating early to bank water ahead.• Stager forage crop cutting dates to avoid
simultaneous peak use.
![Page 71: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/71.jpg)
1109’
1320’
Field #10
20 acres
20 acres
30 acres
30 acres
![Page 72: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/72.jpg)
Crop Water use curve
0
0.05
0.1
0.15
0.2
0.25
0.3
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
Weeks after emergence
Wat
er u
se (i
nche
s)
Series1
Series2
Series3
Series4
Series5
Field beans Soys
Corn
Alfalfa
Field beans
Corn
Soys
Potato
Alfalfa
From Minnesota Extension bulletin “Irrigation Scheduling”, assuming temperature 80-89
![Page 73: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/73.jpg)
Irrigation Scheduling Checkbook Method –University of Minnesota
• Items to Conduct Checkbook Irrigation Scheduling
o Two or more rain gauges o Max-Min thermometer or access to local
temperature reports o Soil probe or in field moisture sensors o Daily crop water use table or local ET hotline or
website report o Soil water balance worksheets o Estimate of soil moisture holding capacity
![Page 74: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/74.jpg)
Jun 21Jun 22Jun 23Jun 24Jun 25Jun 26
757585757575
.17
.17
.20
.20
.17
.17
501.5
3.0
-0--0--0--0--0--0-
2.232.061.891.691.492.071.90
0.75
Frasier 60”SW 1/4
30”
Jun 21Jun 22Jun 23Jun 24Jun 25Jun 26
757585757575
.17
.17
.20
.20
.17
.17
501.5
3.0
-0--0--0--0--0--0-
2.232.061.891.691.492.071.90
0.75
Frasier 60”SW 1/4
30”
0.770.941.111.311.510.931.10
![Page 75: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/75.jpg)
Jun 21Jun 22Jun 23Jun 24Jun 25Jun 26
757585857575
.15
.15
.18
.18
.15
.15
501.5
3.0
-0--0--0--0--0--0-
2.001.851.701.521.341.941.79
0.75
corn 6-1-08SW 1/4
36”
Available
![Page 76: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/76.jpg)
Jun 21Jun 22Jun 23Jun 24Jun 25Jun 26
757585857575
.15
.15
.18
.18
.15
.15
501.5
3.0
-0--0--0--0--0--0-
2.001.851.701.521.341.941.79
0.75
corn 6-1-08SW 1/4
36”
Available
![Page 77: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/77.jpg)
Table 9. Average water use for any other crops when at full canopy at different times of the season
Daily highTemp
May1
2 3 4 Jun5
6 7 8 Jul9
10 11 12 Aug13
14 15 16 Sep17
50-59 .06 .07 .07 .08 .08 .08 09 .09 09 09 09 .08 .08 .08 07 .07 06
60-69 .09 .10 .11 .11 .12 .12 .13 .13 .13 .13 .13 .12 .12 .12 .11 .10 .09
70-79 .12 .14 .14 .15 .15 .15 .17 .17 .17 .17 .17 .16 .16 .16 .14 .13 .12
80-89 .15 .17 .18 .18 .19 .19 .20 .20 .21 .21 .21 .20 .20 .20 .17 .16 .15
90-99 .18 .20 .21 .22 .22 .22 .24 .24 .25 .25 .25 .24 .24 .23 .21 .19 .18
Source: Data estimates full potential of daily ET per week by Killen, and was placed in the above table by Wright in January 2002.
![Page 78: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/78.jpg)
www.agry.purdue.edu/irrigation/IrrDown.htm
![Page 79: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/79.jpg)
MichIana Irrigation Scheduler: Purdue Agronomy web site –Est. From High / Low temp. & date
![Page 80: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/80.jpg)
![Page 81: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/81.jpg)
Date- July 1Stage/
ET.Estimate
July 2Stage/
ET.Estimate
July 3Stage/
ET.Estimate
July 4Stage/
ET.Estimate
July 5Stage/
ET.Estimate
July 6Stage/
ET.Estimate
CornEmerged
May 1.19
1st. Tassel.20 .20 .20 .20
full tassel.22
CornEmerged
May 7.17
10 leaf.17 .19 .19 .19
1st. Tassel.20
CornEmerged
May 14.15
8 leaf.15 .15 .16
.16
10 leaf.17
SoybeanEmerged
May 7
6th. Trifolliate.18
.18 .18 .20 .20
First flower.21
SoybeanEmerged
May 14
4th. Trifolliate.15
.16 .16 .16 .18
6th. Trifolliate
.18
Grass -reference
crop
4” standard.17
4” standard .20
4” standard .17
4” standard .20
4” standard .20
4” standard .20
Mendon Estimated Evapotranspiration (ET) for July 4, 2008Irrigation scheduling links:•Historical E.T. for this site•MSU Scheduler IS 4•MichIana Irrigation Scheduler•MSU Scheduler Excel•MSU Paper check book system
Explanation of estimated E.T..Corn – 105 day maturity emerging on the listed date in 30” rows.Soybean – for grow 3.0 emerging on the listed date.E.T. have been estimate for two days in the future based on future weather forecast.
![Page 82: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/82.jpg)
![Page 83: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/83.jpg)
![Page 84: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/84.jpg)
![Page 85: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/85.jpg)
![Page 86: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/86.jpg)
![Page 87: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/87.jpg)
![Page 88: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/88.jpg)
![Page 89: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/89.jpg)
Irrigation Scheduling Checkbook Challenges
Errors will accumulate over time - Weekly ground truthing needed
Rainfall variability is more than often considered
Only "effective” rainfall and irrigation should be considered - Only water entering root zone uniformly is "effective”
Corn crop mature in program by calendar, not heat
?? Soil Moisture ??
![Page 90: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/90.jpg)
![Page 91: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/91.jpg)
Catch Can Volume (ml)
0
20
40
60
80
100
120
140
160
180
0 200 400 600 800 1000 1200 1400 1600Distance from Pivot (ft)
Can
Volu
me
(ml)
Catch Can Volume (ml)Tower
1Tower
3Tower
5Tower
7 Tower 8
Sprinkler overlap with end gun
WWW.msue.msu.edu/St Joe /Irrigation
![Page 92: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/92.jpg)
Water supply over or under designsupply over design yield tail up, supply under design yield tail down
Example of water supply under volume for sprinkler design
![Page 93: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/93.jpg)
165’
825’
1320’1155’
8 acres6 acres330’
495’
660’
990’
2 acres
18 acres31 acres
49 acres
71 acres
96 acres126acres
10 acres
13 acres
18 acres
22 acres
25 acres
30 acres
Total Acres
Feet from center
4145’3109’
2072’
5181’6217’
7253’8290’
circumference
Over and under
application issue affect the majority
of the application
area
![Page 94: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/94.jpg)
Most system apply within 85% of the expected application
Application is 4 %
under expectation
![Page 95: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/95.jpg)
Measure flow at desired pressure prior to ordering sprinkler package
Poor performance:
Ask dealer to measure flow at peak water use season and compare to design parameters.
![Page 96: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/96.jpg)
Assure the best plant stand
possible
• Irrigate, if necessary, to make sure to get maximum germination and uniform emergence.
• Wet down 2.5” within five days of planting, ½” in most irrigated soil
• Maintain a moist surface,0.10” to 0.20” applications, till spike.
• Are you ready to irrigate the day you plant?
![Page 97: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/97.jpg)
Using irrigation to get the most from pesticides and nutrients
Timely application of irrigation water:• Improves incorporation of herbicides. • Improves activation of herbicides. • Improves activation/reactivation of
insecticides.
• Reduces nitrogen volatilization.• Maximizes yield to utilize the resources.
![Page 98: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/98.jpg)
• Do not apply this product through any type of irrigation system.
• If available, sprinkler irrigate within 2 days after application. Apply ½” -1” of water. Use lower water volumes (½” ) on coarse-textured soils, higher volumes heavier soils (1”) on fine-textured soils.
![Page 99: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/99.jpg)
Chemigation – Application of pesticide via irrigation water.
Fertigation – Application of fertilizer via irrigation water.
![Page 100: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/100.jpg)
Chemigation Label
• Chemigation labels provide specific mixing application and safety precautions for irrigation applications.
• EPA requires products applied through irrigation systems to have a chemigation label.
![Page 101: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/101.jpg)
Calibrating a Center Pivot for Chemigation
![Page 102: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/102.jpg)
Chemigation Valve Requirements
Indiana and Michigan have specific chemigation valve requirements for public water supply connections but not for private water supplies.
Both States require adequate protection of water supply in law or well code.
![Page 103: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/103.jpg)
Most chemigation valves consist of:
4 inch inspection port
injection port for introducing the chemicals
air and vacuum relief valve
spring-loaded check valve
a low pressure drainFlow direction
![Page 104: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/104.jpg)
Chemigation / Fertigation Systems - Safety Interlock
![Page 105: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/105.jpg)
Backflow protection (chemigation valve)
![Page 106: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/106.jpg)
Positive displacement injection pump
![Page 107: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/107.jpg)
Injection nozzle with back flow protection
![Page 108: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/108.jpg)
Storage / mixing tank
![Page 109: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/109.jpg)
High Pressure hose (injection hose, 160 psi)
![Page 110: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/110.jpg)
Supply hose (sized to gravity flow needed volume to pump)
![Page 111: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/111.jpg)
Backflow situation – What do I do?
Pump, Pump, Pump as soon as possible.
Nebraska study showed 990/1000 gallon recovery in the first hour when pumping started immediately.
• 999/1000 gallon after the first day of pumping.• 99.9% one day pumping recovery is reduced 10-
20% if you start 24 hour later.
![Page 112: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/112.jpg)
Equip Groundwater Conservation Program
An NRCS Program to support Irrigation System Evaluations and
System Corrections
![Page 113: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/113.jpg)
Equip Groundwater Conservation Program - Michigan
• Qualifications– System must have been in place for at least 2 years– Must use irrigation scheduling (Computerized or
Paper System)– System uniformity coefficient must be below 85% to
enter, and above 85% to qualify for payments.– Need to have an irrigation conservation plan
• Write up that describes system, water source, how the irrigation is applied,
![Page 114: Irrigation Management Practices](https://reader034.vdocuments.net/reader034/viewer/2022051020/56815a9c550346895dc81d8b/html5/thumbnails/114.jpg)
2009 EQIP Groundwater Conservation Program - Michigan
• Compensation:– A one time payment of $31/acre. (down from $50)– ( was a maximum of 160 acres per producer )– Scheduling is required annual payment of $11.40/acre
(up from $5)
– See you local NRCS office.