Easily Conduct ISO 527 Compliant Tensile Testing Save time and money while doing it! 6000mm/min High Speed Tensile Testing Automatically Perform 150 Consecutive Plastic Bending Testing Easily Conduct ISO 527 Compliant Tensile Testing Improve Efficiency with a Triple-Sample Tensile Testing System Research and Quality Control of Epoxy Resin used in PCBs and ICs Static Friction Coefficients and Kinetic Friction Coefficients ISO 527 (Plastics -- Determination of Tensile Properties) specifies a specific range of data processing methods to use in obtaining data items, such as elastic modulus. ISO 527 prescribes that elastic modulus be determined from the slope between extensions of 0.05% and 0.25%. In order to measure these micro extensions, an accuracy of at least ±1 micron is required for the extensometer (for gauge length of 50 mm). Such measurements are not possible with conventional automatic extensometers. However, Shimadzu´s new automatic extensometer, SIE-560S, satisfies this demand! Additionally, the SIE-560S is capable of measuring both elastic and plastic regions, thus making it possible to measure elasticity and elongation at break point. Another capability of the extensometer is PC control of the extensometer arm opening/closing functions and gauge length setting. This provides ease of operation and reduction of operator-induced error, resulting in significant decreases in sample loss and reduced test-to-test time requirements.

Upload: vo-truong-giang

Post on 02-Jan-2016

69 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ISO 527

Easily Conduct ISO 527 Compliant Tensile TestingSave time and money while doing it!

6000mm/min High Speed Tensile Testing

Automatically Perform 150 Consecutive Plastic Bending Testing

Easily Conduct ISO 527 Compliant Tensile Testing

Improve Efficiency with a Triple-Sample Tensile Testing System

Research and Quality Control of Epoxy Resin used in PCBs and ICs

Static Friction Coefficients and Kinetic Friction Coefficients

ISO 527 (Plastics -- Determination of Tensile Properties) specifies a specific range of data processing methods to use in obtaining data items, such as

elastic modulus. ISO 527 prescribes that elastic modulus be determined from the slope between extensions of 0.05% and 0.25%. In order to measure

these micro extensions, an accuracy of at least ±1 micron is required for the extensometer (for gauge length of 50 mm). Such measurements are not

possible with conventional automatic extensometers. However, Shimadzu´s new automatic extensometer, SIE-560S, satisfies this demand!

Additionally, the SIE-560S is capable of measuring both elastic and plastic regions, thus making it possible to measure elasticity and elongation at

break point. Another capability of the extensometer is PC control of the extensometer arm opening/closing functions and gauge length setting. This

provides ease of operation and reduction of operator-induced error, resulting in significant decreases in sample loss and reduced test-to-test time

requirements.

Page 2: ISO 527

Features

Gauge length setting and extensometer arm opening/closing are PC controlled

Measures elastic modulus to elongation at break point (±1 micron accuracy)

Complies with ISO 527 plastic tensile testing

Semi-automation is possible

Extensometer Details

In addition to the SIE-560S introduced above, the standard model extensometer SIE-560 is also available. Please select the extensometer that best

suits your application.

Specifications

Category SIE-560S (High precision type) SIE-560 (Standard type)

Page 3: ISO 527

Stroke Max. 560 mm (minus gauge length) Max. 560 mm (minus gauge length)

Max. 4 mm Max. 560 mm (minus gauge length)

Measurement accuracy Less than 0.5% of indicated value or ±1µm, whichever is

greater. Guaranteed in the range +18 - +28?C (Fluctuation

during testing within ±2?C)

Less than 0.5% of indicated value or ±2.5

µm, whichever is greater.Guaranteed in

the range +18 - +28?C (Fluctuation

during testing within ±2?C)

Compatible standards ISO 9513 Class 0.5 JIS B7741:1999 Class 0.5 (Method for validating

extensometers used for uniaxial testing) ASTM E83 Class B-2

(Verification and Classification of Extensometer System) JIS K7161

(ISO 527-1) JIS K7162 (ISO 527-2) (Plastics -- Determination of

tensile properties)

ISO 9513 Class 1 JIS B7741: 1999 Class 1

ASTM E83 Class C

Gauge length 50 mm (optionally variable 10 to 40 mm) 10 - 550 mm

Gauge length accuracy Less than 0.5% of set value

Sample

dimensions

Steel 0.5 - 3.2 mm (flat, dumbbell), 4 - 10 mm dia. (rod)

Aluminu

m

1 - 3 mm

Plastic 1 - 4 mm

Arm grip strength 0 to 7 N (variable)

Weight Main unit 28.5 kg; installation base 11.8 kg; adjuster 2 kg

Please inquire for sample sizes not listed above.